3.11 Review and setting the load mode Overloading protection & disposal:
As shown as the right it is the reviewing surfaceof the If the screen shows as the right and thelight it
load mode. numbers represent load mode.
LO AD O N
24 h mean the current of the load loop is 1.2 times othe
f rated current
24h indicating normal mode, loads are under the condition within 3 seconds, and the controller is at overloading state.
After
of supplying power without breakdown; removing some loads, the controller will supply power to the
1h~23h indicating delayed mode of light control, loads start loads automatically within seconds, or you can press button to recover the
to supply power after darkand shun downafter working forthe delayed power supply compulsively.
setting hours
Short-circuit protection & disposal:
Oh indicating light control, loads start to supply power after dark and stop
working after dawn. If the screen shows as the right and thelight it
At this interface, press button for long( 5 seconds),the number tsarts to means there happens short-circuit in the load loop, and thentrol
co ler
and it means the controller enters into theinterface of setting the load is at short-circuit protection state. Please ch
eck whetherthe loads
modes. Use button to adjust this parameter.After setting, are damaged and whether the connecting cables are short-circuit.
press button for long( 5 seconds) to exit this interface and the controller After eliminating the breakdown, press button to recover the power supply
can store this setting number. for the loads.
Breakdown & disposal of solar panels:
Breakdown & disposal Sign means the controller do notdetect the existence of solar panels.
Please check whether the connecting with the solar panels is good
in condition, and
Low voltage protection & disposal: check whether the cables connecting the solaranels
p and the controller are i n
If the screen shows as the right it means thebattery open-circuit condition.
voltage is lower than the protection voltage. The controller Load impulsion breakdown:
enters into the low voltage protection state and the load loop
disconnects. Use the solar panels or charger to charge for the 10.6 V
If when you turn on the load, it means the starting impulsion current is
more than twice of the rated working current. Please restart the controller
for times.
battery. When battery voltage recovers to the protection
Other exceptional conditions: Please contact the distributor or manufacturer.
voltage, the controller will recover to supply power for load,
and enter into the working state. 9 10