DAKOTA U LT R A S O N I C S

THE
MINI-MAX
Bolt Tension Monitor
Ultrasonically measures the actual
elongation produced by tightening
a threaded fastener.

R The FIRST cost-effective ultrasonic


solution available on the market.
R EFFECTIVELY monitor your bolts
during periodic shutdowns over
the service life of the fastener.
R VISUALLY compare the unloaded
to the loaded waveform.
R MEASUREMENT QUANTITIES
Time (nanoseconds), Elongation,
Load, Stress, and %Strain.
R DISPLAY OPTIONS—RF, Rectified,
Large Digits with Limits Bar.
R DISPLAY RESOLUTION
1/8 inch VGA 240 x 160 pixels.
R STORES 8000 readings and
waveforms in multiple groups.
R BUILT-IN linear regression or vector
for optimizing load measurements.
R AUTO SET feature automatically opti-
mizes detection and adjusts display.
R HI/LO ALARM tolerance limits work
in conjunction with the data port and
external pump shut-off device.

S O U N D S O L U T I O N S
M I N I - M A X S P E C I F I C AT I O N S

Physical Power Source Data Logger (Internal)


Size: Three 1.5V alkaline or Total of 8,000 readings in multiple
Width (2.5 in/63.5mm) 1.2V NiCad AA cells. bolt groups. Stores both waveform
Height (6.5 in/165mm) views, nanoseconds, elongation,
Typically operates for 150 hours
Depth (1.24 in/31.5mm) load, stress and strain for each
on alkaline and 100 hours on
Weight: 13.5 ounces NiCad (charger not included). reading.
(with batteries) Memory:
Auto power off if idle for 5 min.
Display: 16 megabit non-volatile ram
Battery status icon.
Membrane switchpad with
twelve tactile keys. Transducer
Measuring
Operating Temperature: Transducer types:
14˚F to 140˚F (-10˚C to 60˚C) Range: Single element (1 MHz to 10 MHz
From 1 to 48 inches & 1/8 to 1inch diameters).
Case: (25.4 to 137 cm)
Extruded aluminum body Locking quick disconnect
with nickel-plated aluminum Time—Nanoseconds “00” LEMO connectors.
end caps (gasket sealed). Elongation—Change in length Standard 10 foot cable.
Data Output: (inches/millimeters)
Custom transducers available
Bi-directional RS232 serial port. Load—Force load applied (pounds for special applications.
Windows® PC interface software. KIP or megapascals MPa)
Temperature probe for automatic
Display: Stress—Force for unit area stress temperature compensation
1/8 inch VGA grayscale display applied (inches per inch or
(240 x 160 pixels); millimeters per millimeter)
Viewable area 2.4 x 1.8 inches
Features
(62mm x 45.7mm); Resolution: Setups:
EL backlit (on/off/auto) +/- 0.00001 inch (0.0001 mm) 64 custom user defined setups;
Velocity Range: 0.0492 to .3937 Factory setups can also be
Ultrasonic Specifications in/ms (1250 to 9,999 meters/sec) edited by the user.
Measurement Modes: Fixed, Single, and Two-point Gate:
Pulse-Echo (standard) zero calibration options. Gate used to fine adjust where the
Pulse-Echo w/Gate (fine adjust) detection point occurs.
Select bolt material types from a
Pulser: preset or custom list. Alarm Limits:
Square wave pulser with Set Hi and Lo tolerances with
Units:
adjustable pulse width audible beeper, viewable scan bar,
English & Metric / Farenheit &
(spike, thin, wide). and visual LEDs.
Centigrade.
Receiver: Auto Set:
Manual or Auto Set gain control Display Locates the detection signal,
with 40dB range. optimizes the gain setting, and
A-Scan—Rectified +/- (half wave adjusts the overall display to show
Timing: view), or RF (full waveform view). the waveform and detection point
10-bit 250 MHz digitizer. automatically.
Large Digits—Display and toggle
Warranty between nanoseconds, elongation, Field Calibration:
2 year limited load, stress, and strain; Vector & linear regression
Digit Height: 0.400 inch (10mm).
Limits Bar (alarm limits)— Set Certification
Hi & Lo alarm limits for displaying
Factory calibration traceable to
an acceptable tolerance range.
national standards.
Repeatability Bar Graph—
Bar graph indicates stability of
9/05 (05-104/2.5M)

measurement.

A S O N A T E S T P L C G R O U P C O M P A N Y

Distributed by:
DAKOTA ULTRASONICS
300 El Pueblo Road, Suite 100
Scotts Valley, CA 95066
TELEPHONE: 831.431.9722
FAX: 831.431.9723
WEB SITE: www.dakotaultrasonics.com
E-MAIL: [email protected]