VL802 Command List1205
VL802 Command List1205
NO Function Command
VERSION#
1 Query the version.
VERSION,BUILD#
9 DW#
Request for the location of the
10 POSITION#
device (SMS only)
11 Check the lock status of the 123 #
12 current domain name of the QLOCKIP#
device.
ers.
[VERSION]ET310_TEST_V01_20200520_0900
[BUILD]20200520_0900
CMnet,,;10,10;180;E8,0;1,test.topstargps.com,11139;,,;;10;10;1;
Battery:3.85V,NORMAL; GPRS:Link Up GSM Signal Level:Low;
GPS:OFF; ACC:OFF; Defense:ON;
IMEI:;
VERSION:ET310_TEST_V01_20200520_1425;
SERVER:1,test.topstargps.com,11139;
BSERVER:0,0.0.0.0,0;
GET IP:120.234.211.126;
APN:CMnet,,;
CSQ: [4G]13;
GPRS:1;
GPS:OFF;
BDS:OFF;
BAT:3.79;
POWER:0.00;
TIMER:10,10;
SOS NUM:,,;
CENTER:,,;
CELL:NB-Iot,searching(1);
IMSI:460044335609859;
ICCID:898604231919C2690159;
EURL:http://maps.google.com/maps?q=;
NO Function Command
2 Reboot RESET#
1 Set APN
5
Set server parameters
6 Edit URL
7 GPRS switch
Set the interval for sending heartbeat packets
8
and check the setting.
9 Set the time interval to upload GNSS data
10 Set the distance interval to upload GNSS data
11 Set the parameters to upload additional fixes
Set the parameters to upload a position fix when
12
the ACC
Set state changes
the parameters to send the GNSS data in
13
batch
14 Force upload location data switch
15 Set the state of AGPS
16 Set the parameters of the static data filter
17 Set the parameters to upload LBS data
18 Mileage statistics
Set the visible satellites information upload
19
parameters
Set the time and condition for the sensor to
20
activate
Set the GNSS to
the parameters module
upload the voltage data of
21
external power
22 Set the LED
23 Set the petrol/electricity control
24 Set the defense mode
25 Set the defense parameters
26 Set the defense manually.
51 Mutual Communication
52 Bluetooth open
53 Set permissions scheme for phone numbers
54 Set permissions for SOS numbers
55 Set I/O1
56 Set I/O2
57 Inputmode1 alert【eg:Door status check】
58 Inputmode2 alert【eg:Door status check】
59 Outmode set
60 ADC voltage alarm
61 Variable IO detection trigger mode
62 Side door open alarm
63
APN,apnname#
OR APN,apnname,user,pwd#
APN#
ASETAPN,SW#
ASETAPN#
GMT,A,B,C#
GMT#
ASETGMT,SW#
SERVER,mode,domainName/IP,port,protocol#
SERVER#
EURL,URL#
GPRSON,SW#
HBT,T1,T2#
TIMER,T1,T2#
DISTANCE,D#
ANGLEREP,SW,A,T#
ACCREP, SW#
BATCH,SW,N#
GPSDUP, SW#
AGPS, SW#
SF,SW,D#
LBSON,SW,T1,T2#
MILEAGE, SW,L,K#
SV,SW,T1,T2#
SENDS,T1,T2,N#
ADT,SW,T#
LEDSW,SW#
RELAY,M,V#
DEFMODE,M#
DEFENSE,T#
111 #
000 #
CALL,N#
ACCALM,SW,M,T,N#
LEVEL,M#
STATICREP,SW,T,V,N#
SENALM,SW,M,N,T1,T2,T3#
POWERALM,SW,M,T1,T2,T3#
BATALM,SW,M#
EXBATALM,SW,M,V1,V2,T#
MOVING,SW,M,R#
SPEED,SW,M,V,T#
JT,A#
DIAL,A,M#
BLETOOL, <SW>#
PERMIT,<M>#
SOSPERMIT,<M>[,Y]#
IOMODE1,<M>#
IOMODE2,<M>#
INPUT1ALM,SW,M, C,T#
INPUT2ALM,SW,M, C,T#
OUTPUTSWITCH,SW,X,[T]#
ADC1ALM,SW[,M][,VH][,VL]#
iotrig_set,<M>,<A> #
DOORALM,SW,M #
SMSINPUT,[A],[B]#
MONPERMIT,<A> #
MONDELAY,<A> #
buzzer_overtime, <SW>[,A] [,B]#
buzzer_overspeed, <SW>[,A] [,B]#
ENGALM,<SW>[,M] #
ENG,<SW>[,V][,T]#
UL212SW,SW#
NTTOILTIME [,A] [,B]#
UL212OILALM [,A] [,B] [,C]#
Explanation
SW=ON/OFF;
ON: open automatic APN;
OFF: close automatic APN.
A:E or W;"E" means eastern time zone,"W" means western time zone;default:E
B:0~12;time
Check the current zone
timedefault:8
zone parameters
eg: SERVER,1,gpsdev.tracksolid.com,21100,0#
SW: SERVER,0,47.89.58.215,21100,0#
ON or OFF.
The default value of “SW” is ON.
mode = 1 means set with domain name
mode
Check=the 0 means
currentset withparameters
sever ip address
protocol
URL: It refers to the locationserver
= 0 means connect querywith
link.TCP protocol
protocol = 1 means connect server with UDP protocol(Not use for now)
SW: ON or OFF.
The
T1:the default value
interval of “SW”
to upload is ON. heartbeat packets, ranging from 1 to 10 minutes.
ACC_ON
T2: the interval to upload ACC_OFF
T1 ranges 1~18000 or 0(seconds),upload heartbeat packets,
interval whenranging
ACC ON,from 1 to 10no
0 means minutes.
upload,default
is 10;
D ranges 50~10000 or 0(meters),distance interval,0 means no upload,default is 300; If set
distance,
SW:ON or timer
OFF;will not work.
A: theON
SW: angle threshold, 5~180 degrees;
or OFF.
The defaultOFF.
SW:ONor value of “SW” is ON.
N:
SW: theON pieces of data in a batch, 1~10 pieces.
or OFF.
Note:ON
SW: Theordefault
OFF. value of “SW” is OFF.
Note:
SW: ON or OFF. value of “SW” is ON.
The default
D:
SW: theON maximum
or OFF;distance interval to enable static data filter, 100~10,000 meters.
T1: the
SW: ONinterval
or OFF; to upload the data, 10~3,600 seconds;
L:
SW: ON or OFF; initial value of the mileage reading, ranging from 0 to 999,999 km. If L is set
It specifies the
to
T1:“0”,
T1: It itupload
meanstime
thespecifies to clear
how longthe
interval,
willmileage
5the data.seconds;
~ 18,000
GNSS module run after being activated, ranging from 0 to
300 minutes;
SW: ON or OFF;
T: It specifies
SW:ON or OFF;the upload interval, ranging from 5 to 3,600 seconds.
Note:
M: The default
It indicates thevalue is OFF.
fuel and power supply status, where “0” means the fuel and power supply is
connected and “1” means
M: It indicates the defense mode, the fuel where
and power supplytoisautomatic
“0” refers cut. mode and “1” manual mode.
Note: The default value is “0”.
T: It specifies the delay to enable the defense mode, ranging from 1 to 60 minutes.
Note: The defense mode is disabled by default. The default value of “T” is “3”.
SW: ON or OFF;
M=0/1
SW: ON,0=GPRS;
or OFF; 1=SMS+GPRS;
M=0/1
SW: ON or OFF; 1=SMS+GPRS;
,0=GPRS;
M=0/1/2/3
SW: ON or0=GPRS,
OFF; 1=SMS+GPRS, 2=GPRS+SMS+Call, 3=GPRS+Call.
M=0/1 ,0=GPRS; 1=SMS+GPRS;
Circular geofence setting: N: It refers to the geofence number, ranging from 1 to 5;
SW: ON or OFF;
LNG: It indicates longitude of the center coordinate;
LAT: It indicates the latitude of the center coordinate;
R: It indicates the radius of the geofence, whose unit is a hundred meter;
X: It specifies what types of geofence alerts will be uploaded, where “IN” refers to entering
geofence alert, “OUT” leaving geofence alert, and null entering and leaving geofence alerts;
M=0/1 ,0=GPRS; 1=SMS+GPRS;
Note: The third parameter is fixed at “0”, which means it is a circular geofence.
A:phone number
M:phone call Times 1-10
SW: ON/OFF. The default value is “OFF”
M:
M: It
It indicates
indicates the
the permissions
permissions scheme,
scheme, whose
whose value
value is
is either
either "0"
"0" or
or "1".
"1";
Note: The default value is "0" (0#).
Y: It specifies the polling method of alert packets, where "0" means to send alert packets to the
IO1
first configuration
valid SOS numbercommand: IOMODE1,<M>#
and "1" means to send alert packets to all SOS numbers.
SW:
M:
IO2
Note: switch,
input ON/OFF;
0:configuration
mode;
The default 1: output
are mode;
command:
values "0" and2:"1"
buzzer
IOMODE2,<M># mode;
(0,1#).
M: Alarm
Default: 0 reporting method, 0 only GPRS,
M: 0: input mode; 1: output mode; 2: buzzer mode;1 SMS+GPRS;
C: detection
Default: 0 mode, 0: trigger alarm in active state; 1: trigger alarm in inactive state; 2: trigger
alarm in both active and inactive states
T: Active state duration, (1s to 60s)
Default: (OFF,0,0,10#)
SW: switch, ON/OFF;
M: Alarm reporting method, 0 only GPRS, 1 SMS+GPRS;
C:
ADCdetection
voltagemode,
alarm 0: trigger alarm
command: in active state; 1: trigger alarm in inactive state; 2: trigger
ADC1ALM,SW[,M][,VH][,VL]#
SW:
alarmON/OFF.
in both ON: Continuous
active and inactive open-drain
states output; OFF: Stop open-drain output;
SW:
X: switch,
output pinON/OFF;
T:
M: Active state
Alarmdrain duration, (1s to
reporting 60s) GPRS, 1 SMS + GPRS;
Variable
T: Open
Default: IO outputmethod,
detection
(OFF,0,0,10#) trigger 0mode
duration only
(1s tocontrol
10s) command: iotrig_set,<M>,<A> #
VH:IOadc
M: voltage
port optionhigh
1: IOalarm
portvalue,
1 2: IOsetting
port 2range: 0to5V, setting concentration 0.1V
SW:
VL: switch,
adc
A: Trigger ON/OFF;
voltage
mode low alarm value,
0: Negative setting
trigger range: trigger
1: Positive 0to5V, setting concentration 0.1V
M: Alarm reporting
Description: Default method,
setting 0 only GPRS, 1 SMS+GPRS;
(ADC1ALM:OFF,0,4.5,1.0#)
Description: Default value (1,0#) (2,0#) 2 SMS+GPRS+CALL
Default: (OFF,1#)
A: Answer method:
0: No answering 1: Only the center number is allowed to answer 2: SOS number and center
number are allowed to answer (default) 3: Any number can answer:
Description: Default value (2#)
Overtime alarm buzzer reminder command: buzzer_overtime, <SW>[,A] [,B]#
SW: switch,
A: Delay timeON/OFF;
(5-20 seconds)
A: 1 is
Overspeedcontinuous
Description:alarm reminder,
buzzer
Default 2 is intermittent
reminder
value (10#) command: reminder (sound for<SW>[,A]
buzzer_overspeed, 2000ms and then silence for
[,B]#
6000ms)
SW: switch, ON/OFF;
B:
A: Timeout period reminder,
1 is continuous
SW:ON/OFF; for continuous reminders (1-60
2 is intermittent minutes)
reminder (500ms beep and 3000ms silence)
Description:
B: Timeout
M:0 Default value
periodSMS+GPRS;
:GPRS,1 (ON,1,5#)
for continuous reminders (1-60 minutes)
Description:
Default Default value (ON,1,5#)
value(ON,0#)
SW: switch, ON/OFF;
V: voltage constant, setting range 90-360, unit 0.1V;
T: time value, setting range 0-60, unit second;
Description: Default value (ON,128,10#).
SW:ON/OFF
A: Detect
A: 10~600alarm default
(seconds) is off
ACC
content ON detect
0: Not detection time
alarm 1: Oil stealing alarm 2: Refueling alarm 3 Oil
B:
stealing+refueling alarm OFF detection time
10~600 (seconds) ACC
Description: Defaultmethod,
B: Alarm reporting value (60,60#)
0 only GPRS, 1 SMS+GPRS;
C: Alarm silence time (2-60 minutes)
Description: Default value (0,0,2#)