CLE Spec Sheet
CLE Spec Sheet
APPLICATION
Hazardous Location applications, such as gas compression and off shore.
System Area Classification: Class 1 Div. 1&2 Group D
SPECIFICATIONS
• Heating Fluid: Engine coolant • Pump Power: 1 Hp (0.75 kW)
• Heat Power: 6-36 kW • Maximum Pressure: 100 psi (690 kPa)
• Voltage Range: 240, 440-480, 575-600V • Pressure Relief Valve Setting: 90 psi (620 kPa)
• Temperature Controller: Adjustable 32-212°F (0-100°C) • Inlet Plumbing: 1.25” NPT
• Temperature Setting: 120°F (50°C) • Outlet Plumbing: 1.0“ NPT
• High Limit Temperature Control: Adj. 32-212°F (0-100°C) • Main Control Box Ingress Protection: NEMA Type 4
• High Limit Temperature Setting: 195°F (90°C) • Motor Ingress Protection: XPFC
• Fluid Capacity: 1 gal (3.8L) • Temperature Class: T2C
• Altitude Rating (Motor): 3,300 ft (1,000m)
FEATURES
• Certification: CSA
• Switch: Local/Off/Remote
• Remote On/Off Signal: 24VDC
• Compact design
• Easy to install
• Failsafe Operation
www.hotstart.com