Implimentation Survey Report

Site ID: MAK0643 Tower Height= 30 m Tower Type RDS-30 m


Buidling Height: 0 Sharing Operator: NA Host : NA

Sharing information:
Mobily STC
Sharing Operator Antenna: NA NA
Sharing Operator RRU: NA NA
Sharing Operator MW: NA NA
Before Implementation:
Existing MW Antenna: 4
1*1.8 NEC + (2*0.3 +1*0.6 )NOKIA
Total GSM Antennas: 6
RRU Quantity: 5
5 * RRU (2*FRGT +2*FXDB +(1*ARMA )+(1*FXED)+(1*FRGT) )
Ant. Type1: RV4-65D-R5-V2
for G900/U2100/L800/L1800/L2100
Ant. Qty: 3
Ant. Dim: L2.688 X W 0.35 X D 0.208

Ant. Type2: AEHC


for NR2600
Ant. Qty: 3
Ant. Dim: L.0.97 X W 0.545 X D 0.205

Total MW Antenna: 4
1*1.8 NEC + (2*0.3 +1*0.6 )NOKIA

After Implementation:
Total GSM Antennas: 9
RRU Quantity: 4
4* RRU (2*FRGT +2*FXDB +1*ARMA +1*FXDB)

Ant. Type: RV4-65D-R5-V2


for G900/U2100/L800/L1800/L2100
Ant. Qty: 3
Ant. Dim: L2.688 X W 0.35 X D 0.208

Ant. Type2: AEHC


for NR2600
Ant. Qty: 3
Ant. Dim: L.0.97 X W 0.545 X D 0.205
New RRU Qty: NA

Add New Ant: AQQT


for NR3500
New Ant Qty: 3
New Ant. Dim: L.1.001 X W 0.448 X D 0.152

Total MW Antenna: 4
(2*0.3 +2*0.6 )NOKIA
Sector A:
Add New Antenna
Keep Existing both SEC A Ant's RV4-65D-R5-V2 FOR
G900/U2100/L800/L1800/L2100 + AEHC For NR2600 ) And
REUSE EXISTING MOUNT For NEW AQQT Ant sec A

Azimuth : 40 Height: 30

Mount Proposal : NO
Mount Quantity : NA

REUSE EXISTING MOUNT For NEW AQQT Ant sec A

Feeder/CPRI/Power Cable Length : 40 m

Azimuth : 40 Height: 30

Scenario Introduce NR 3500 MHz


Antennas must be installed As per SAF Azimuth
New CPRI will be installed instead of dismantled ones
Blockage Proposal (If any) :

Sector B:
Add New Antenna
Keep Existing both SEC B Ant's RV4-65D-R5-V2 For
G900/U2100/L800/L1800/L2100 + AEHC For NR2600 ) And
Reuse Need new mount To Install NEW AQQT Ant sec B

Azimuth : 190 Height: 30

Mount Proposal : YES


Mount Quantity : 1

need new mount to install NEW AQQT ANT Sec B

Feeder/CPRI/Power Cable Length : 40 m

Azimuth : 190 Height: 30

Scenario Introduce NR 3500 MHz


Antennas must be installed As per SAF Azimuth
New CPRI will be installed instead of dismantled ones

Sector C:
Add New Antenna
Keep Existing both SEC A Ant's (RV4-65D-R5-V2 For
G900/U2100/L800/L1800/L2100 + AEHC For NR2600 ) And
Instal new pole For NEW AQQT Ant sec C

Azimuth : 270 Height: 30

Mount Proposal : YES


Mount Quantity : 1

Required new mount to install new AQQT ANT SEC C

Feeder/CPRI/Power Cable Length : 40 m

Azimuth : 270 Height: 30

Scenario Introduce NR 3500 MHz


Antennas must be installed As per SAF Azimuth
New CPRI will be installed instead of dismantled ones
Blockage Proposal (If any) :
MW Outdoor Action After Implemtation
Add New Antenna
DISMANTLE 1.8 /1+0 NEC Link MAK0634-MAK0984
Reqired new mount 2m to install New UBT 4+0 XPIC 0.6 link
( Azm 244.43 / HIGHT 16M ) MAK0634-MAK0984
Hei
Azimuth : 244.43 16
ght:
Mount Proposal : YES
Mount Quantity : 1
new mount 2m to install New UBT 4+0 XPIC 0.6 link
( Azm 244.43 / HIGHT 16M ) MAK0634-MAK0984

CPRI/Power Cable Length: 25 m

Blockage Proposal (If any) :


Existing Cabinet/Rack:

2G(G900)…....1*ASIA
3G(U2100)….1*FSMF +1*FBBA
4G(L800/L1800/L2100)..... 1*ASIA+2*ABIA
5G(2.6 NR).......1*ASIB +3*ABIL

BBU/Cards Solution:

Reuse existing AMIA (A*ASIB/2*ABIA) and add 1*ABIO


Dismantle 1*ASIA +3*ABIL
DISMANTLE 3G (1*FRGT +1*FSMF+1*FBBA)

MW Indoor Action After Implemtation

DISMANTLE ipaso 1000 MAK0634-MQK0984 & use existing


MSS8 for New link
Existing DCDU:

NA
Existing DCDU

DCDU Proposal :

Need to INSTALL 2*100A (2 For new dc panel ) and shift 2 module to NA


existing FPFH
Reuse existing FPFH free 3 ports for 3 new AQQT

Existing Circuit Breaker (CB):

Existing Circuit Breaker (CB)

DC Calculation :

DC Load = 131 A

EATON Rectifier- 1800 W

7 Rectifier Modules Available

2 Slots free for Rectifier Module

Rectifier Module need to add

Rectifier Swap Scenraio :

Remakrs:

Battery :

NORTH STAR
• BATTERY TYPE:

1 STRING 4 BATTERIES
• Batteries Qty:
12V*151 AH
• Capacity:

New Battery Space Available :

•New BATTERY TYPE:


Under Nokia
• New Batteries Qty:

• Capacity:

Remarks: ________________

DC cable size for battery Available :

Add Details 4*10mm


Add Picture and mark location

• Space Available:

GPS :

NA
Existing GPS
SCECO Breaker Information :

EXISTING SCECO BRAEKER

CAPACITY: A Not available sceco ,only cable

NA

SCECO Meter Information :

EXISTING SCECO Meter #

NA

Meter CAPACITY: NA A

Transformer Information :

Transformer CAPACITY: 60 KVA


NA

Generator Information :

Generator CAPACITY: KVA


Not available

Generator Brand:

Existing ZAIN Breaker

CAPACITY: 125 A NA

Site Phases Information :

SCECO VOLTAGE PH to PH
VOLTAGE: 220 V

EXISTING PHASE-01

Current: 24.2 A
EXISTING PHASE-02

Current: 15.3 A

EXISTING PHASE-03

Current: 14.4 A

Tenant Phases Information (incase sharing load):

EXISTING PHASE-01

NA
Current: A

EXISTING PHASE-02

NA
Current: A

EXISTING PHASE-03

NA
Current: A
AC cable size Information :

MDB to Rectifier 4*16mm mm2

Need Pic For Cable Size

AC cable size Information :

Generator to shelter mm2


Need Pic For Cable Size

AC cable size Information :

NA

SCECO Breaker/MCCB to Shelter 16 mm2

ODC/shelter Aircon-1 Information :

Aircon-1 status: ___ WORKING

Add clear Picture of Aircon & specification Plate


Airocn Capacity:_______________________ BTU

ODC/shelter Aircon-2 Information :

Airco-2 status: __________________WORKING_________

Airocn Capacity:_______________________ BTU

EXISTING SITE TEMPERATURE


NA
TEMPERATURE: NA C
Site Info.

SM istalled
Site Final Need Access Shelter In(BTS/Rect
Site ID Need crane Project SCOPE
Type Access contact /ODU fier
cabinate )
Rectfier
Sophia
MAK0634 RDS-30 m NA NA NA Shelter cabinet & C Band Expansion + MW Link
Phase 4
BTS
Nokia NEC

CIVIL FB Power FB TX FB 0.3 0.6 1.2 1.8 0.3 0.6 0.8

NA na NA 2 1 0 0 0 0 0
EXISTING TI&TX DATA
NEC

0.9 1.2 1.8 2.5 3.5 900 Band ANT Type 3G Band ANT Type

0 0 1 0 0 3*10PORT 3 * RV4-65D-R5-V2 share share


EXISTING TI&TX DATA
Antenna data

1800 Power
Band/LTE ANT Type AEHC ANT Type C-BAND ANT Type wifi GPS Ant F/FL cable
Band/2100 length

share share 3 3*AEHC NA NA NA 1 FL 40


Nokia

fiber cable
# OF RRU/BOX 0.3 0.6 1.2 1.8
length

40 5 * RRU (2*FRGT +2*FXDB +(1*ARMA )+(1*FXED)+(1*FRGT) ) 2 2 0 0


Nokia _Planed TL Data
NEC

0.6 0.9 1.2 1.8 900 Band


0.3 ANT Type 2G Band ANT Type
LTE 800

0 0 0 0 0 3*10PORT 3 * RV4-65D-R5-V2 share share


_Planed TL Data
Antena Data
New
1800
SM
Band/LTE ANT Type AEHC ANT Type C BAND ANT Type wifi GPS
Locati
Band/2100
on

share share 3 3*AEHC 3 3*AQQT NA 1 NA


RRU on tower

4* RRU (2*FRGT +2*FXDB +1*ARMA +1*FXDB)


Site Inforamation

Site ID Region Project Scope

MAK0634 West Sophia Phase 4 C Band Expansion + MW Link


oramation AC Information
Cabinet
Type Meter SCECO
Tech Site Type( Power Type
(Shelter/ Owner Capacity
ODC)
C Band Expansion + MW Link GF Shelter SCECO NA 125
AC Information DC Information
Voltage
Transfor DG Rectifier Max No
3-Phase Rectifier Module
mer Capacity Module Free Slots Of Battery Type
(220V/38 Type Capacity
(KVA) (KVA) QtY Modules
0V)
220 60 NA EATON 7 2 9 1800 NORTH STAR
DC Information Proposed
Dismantli
DC
Battery New Load ng DC Total
No of Battery cell DC Load (A) Consider
capacity max (A) Equipmen Load (A)
Load
t
12*151 1 SRING (4 BAT) 131 131 95.6 46.5 180.1
AHP4518R5v06
ASI4518R42v06
ASI4518R10v06
AOC4518R3v06
APE4517R0
ASI4518R10v18
AAU5614
AAU5613
AAU5639w (2.6G)
AAU5639w (3.5G)
A19451902
A704521R0
ASI4518R10
ATR451704v01
AOC4518R8v06
APE4517R0v06
ATR4518R11
AAU3911
A264518R0v01
ATR451714
ADU4518R8v06
ASI4517R3v06
AQU4518R25
AOC4518R0v06
A79451700V02
ADU451801
742236v01
742 266
ADU4518R8
A19451811
APE4516R1v06
ATR4518R14
ADU4518R0v06
A704517R0
ADU4517R6v06
80010305V02
A704517R0v06
ADU451807v01
LBX-3319DS-TOM
ADU4521R0v06
ADU451712v06
K739624
K742213v01
A90451800
ATR451704
TDJ-809018DME-65P
HBX-6517DS-VTM
ATR4518R4
AAU5636
ADU451902v06
TBXLHA-6565C-VTM
K80010204
A19451811v06
DBXLH-6565A-VTM
K742224
K739623
LBX-3319DS-T0M
K80010302
ADU4517R2
A794517R0
RRU5309 (L800)
RRU5509t (G900/L800)
RRU3936
RRU3953
RRU5904 (L1800)
RRU5904 (L2100)
RRU5904 (L1800/L2100)
RRU5513 (L1800/L2100)
RRU5909N (L1800)
RRU5909 (L2100)
RRU5309 + RRU5909N (L800/L1800)
RRU5309 + RRU5909 (L800/L2100)
RRU5909N + RRU5909 (L1800/L2100)
RRU5309 + RRU5904 (L800/L2100)
RRU5509t (G900/L800) & RRU5513(L1800/L2100)
RRU5509t (G900/L800) & RRU5909 (L2100)
RRU5309 (L800) + RRU5513 (L1800/L2100)
A704521R0v06
AAU5636m
AAU5636w

You might also like