Name Title DTC SPN SAE FMI Component OBD System (Readiness) Symptom Bit TypDfp IVECO Tester Code OBD Code General Remark Test Condition Fault Detection Defect Debouncing Fault Healing Healing Debouncing System Reaction Fault Disabling Disabled Failure Cause Failure Repair Error Class Priority Error State Behaviour Visibility Level Visible OBD scan tool Long Term Failure Sys.Lamp MIL Fault Counter (Validation Fault Counter Healing Counter (Validation Healing Counter Delete Counter (Validation Event) Delete Counter DLC Pending (Validation Event) DLC Pending DLC from State2 (Validation DLC from State2 Amb Cond Name Amb Cond Description Amb Cond TroubleshootingAdvice Fid Name Fid Description Performance Limiter
Event) (Number of Events) Event) (Number of Events) (Number of Events) (Number of Events) Event) (Number of Events)
1) indicates operating point, when failure occured
2) indicates operating point, when failure occured
1) Eng_nAvrg __n_DLen2 1) average engine speed
3)
2) InjCtl_qSet__q_DLen1 2) fuel mass set value
4)
3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands 1) Fid_APP1 1) Accelerator pedal value is forced to 0%, and plausibility check is switched off
5) indicates if battery voltage was extraordinare which could be
This function monitors the analog-digital converter 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 2) Fid_APP2 2) Acclerator pedal value is forced to 0% and plausibility check is switched off
P060B An error is detected if not all ADC queues are ECU recovery (reset) the reason for the defect detection
ECU internal fault: Analog to Digital conversion (ADC) of the microcontroller. The test pulse for the 5) BattCD_u__uBatt_DLen2 5) Battery voltage 3) Fid_HpTst 3) Inhibits high pressure test
ADCMon 1D9 65753 12 ECU Internal non NPL 3 12 Queue Error Internal Control Module A/D Processing Continuously converted within a time window. Time and engine speed Defect condition fulfilled continuosly > 150.0 ms No healing, since the error reaction is a ECU recovery None Buffer overrun No intervention necessary 2 2 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp ON Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3 6) indicates engine temperature (low or very high temp can
failure Sig error consists of cyclically setting the ADC 6) FTSCD_tFuel__t_DLen1 6) Fuel temperature 4) Fid_PRVMon 4) Error reactions of rail pressure relief valve
Performance synchronous queues are monitored Further reactions according to FIDs indicate ambient temp problem of relay)
channel of the acc. pedal (APP2) to zero. 7) IATSCD_tAir__t_DLen1 7) intake air temperature 5) Fid_RailCtlMode 5) General error inhibiting for rail pressure governor
7)
8) CTSCD_tClnt__t_DLen1 8) Coolant temperature
8) indicates engine temperature (low or very high temp can
9) APPCD_uRawAPP1__u_DLen1 9) accelerator pedal 1 position raw value
indicate ambient temp problem of relay)
9)
P0541 The power stage for air heater 1 is monitored by Not in afterrun and Not on main relay switch off Power stage hardware does not report 'short circuit to
0 4 MIN 1 4 Short to Ground Power stage hardware reports 'short circuit to ground' Defect condition fulfilled continuosly > 500.0 ms Healing condition fullfilled continuosly > 1500.0 ms Reactions according to FIDs Short circuit of wiring to ground or inside relay. Check of wiring or replace relay.
Intake Air Heater “A” Circuit Low hardware for electric failure. ground'
Power state not disabled i.e Not in afterrun and Not on
main relay switch off
Monitoring only when the power stage is not actuated
P0543 The power stage for air heater 1 is monitored by Not in afterrun and Not on main relay switch off
0 2 SIG 2 2 Open Load Power stage hardware reports 'open load' Defect condition fulfilled continuosly > 500.0 ms Power stage hardware does not report 'open load' Healing condition fullfilled continuosly > 1500.0 ms Reactions according to FIDs Broken or disconnected wiring or defective relay. Check of wiring or replace relay.
Intake Air Heater “A” Circuit Open hardware for electric failure.
Power state not disabled i.e Not in afterrun and Not on
main relay switch off
1) Use default airmass out of AFSCD_dmAirSubsVal_MAP f(fuel quantity + engine speed).
FID for airmass per unit time calculation
2) Air pressure calculation only out of boostpressure during low load conditions
1) Fid_AFSCD_AirPerTime
3) Use of substitute value for ASMod_rLmbdRecEG (see: ASMod_Eng). in case of defect
2) Fid_APSCD
sensors or actuators
3) Fid_ASModSwtOffEng
4) Substitute value output instead of corrected upstream at mixing point. in case of defect
4) Fid_ASModSwtOffIndVol
sensors or actuators
5) Fid_ASModSwtOffObsvr
5) Controller is switched off, initialized and outputed zero.(only this bad expl.avl.!!!). switch
6) Fid_AirCtlBPSCorIv
off the lambda observer ASMod_Obsvr in case of defect sensors or actuators
7) Fid_AirCtlIv
6) EGR setpoint correction shut off
8) Fid_CRERBstErrIv
1) indicates operating point, when failure occured 7) Air mass control is switched off
9) Fid_CrCtlBstPres
2) indicates operating point, when failure occured 8) Fixed Engine brake valve activation delay time, in case of defective boost pressure sensor.
1) Eng_nAvrg __n_DLen2 1) average engine speed 10) Fid_CRERBstErrIv
3) 9) Cruise control shut off condition, in case of defective boost pressure
2) InjCtl_qSet__q_DLen1 2) fuel mass set value 11) Fid_DewPntIv
4) 10) Fixed Engine brake valve activation delay time, in case of defective boost pressure
3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands 12) Fid_EGSysPresCalc
5) sensor.
The boost pressure is switched to the default value 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 13) Fid_EGSysTrbn
P0238 6) can be used to evaluate the effective boost when failure 11) Sets dew point detection out of PFlt or EGT temperature (see EDC2NoxIv Figure) . 1) yes (technical) because of Fid_CoEng_trq LimErr
The boost pressure sensor is monitored by hardware The sensor raw voltage value BPSCD_uRawVal is The sensor raw voltage value BPSCD_uRawVal is 2.70bar. 5) BPSCD_pFltVal__p_DLen1 5) filtered value of boost pressure. 14) Fid_EPCtlIntactP2
BPSCD Boost pressure sensor 134 65588 3 Boost pressure non MAX 0 3 Signal too high Turbocharg er/Supercharger Boost Sensor "A" Continuously Defect condition fulfilled continuosly > 500.0 ms Healing condition fullfilled continuosly > 2000.0 ms Sensor defective or short circuit to external source Check wiring or replace sensor. 2 2 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp ON Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3 occurred 12) Switches the exhaustgas backpressure model to replace map in case of faulty input 2) yes (technical) because of Fid_CoEng_trq LimErr3
for electric failure. above 4.85V below 4.85V 6) APSCD_pVal__p_DLen1 6) atmospheric pressure 15) Fid_EngPrtOvhtPrv
Circuit Hig h 7) indicates if battery voltage was extraordinare which could be signals
Further reactions according to FIDs 7) BattCD_u__uBatt_DLen2 7) Battery voltage 16) Fid_ExhVlvBstErrIv
the reason for the defect detection 13) Switches to default value EGSys_tEGPstTrbnDfl_C instead calculated downstream
8) IATSCD_tAir__t_DLen1 8) intake air temperature 17) Fid_FrmMngBPS
8) turbine EGSys_tEGPstTrbnStat
9) CTSCD_tClnt__t_DLen1 9) Coolant temperature 18) Fid_SCRCatUreaRedIv
9) indicates engine temperature (low or very high temp can 14) Indicates boost pressure sensor defect and deactivates related use in Exhaust
19) Fid_NOxBPSCDIv
indicate ambient temp problem of relay) PressureControl managment
20) Fid_CoEng_trq LimErr
15) Switches overheat prevention off
21) Fid_CoEng_trq LimErr3
16) Uses default value ExhVlv_pBstDflValIv_C for the delaytime calculation of the exhaust
22) Fid_FrmMngEngDg rtLvl3Iv
brake activation.
23) Fid_PCRGradP2Iv
17) Transfers the default value 0xFE as boost pressure in byte2 of CAN-frame INCON
24) Fid_PCRIntactP2
18) Reduces urea injection quantity in case of engine anomalies
25) Fid_SCRCatBefCatTempIv
19) Boost pressure is no more taken into account for NOx estimation correction
26) Fid_SCRCatUreaRedIv
20) Activates torq ue limit CoEng_trq LimErr_CUR, and enables further curves 2,3,4 (main
27) Fid_CrCtlBstPres
torq ue limit switch)
21) Activates limit CoEng_trq LimErr3_CUR only in addition to Fid_CoEngTrqLimErr_mp.
22) Transfers engine degradation level 3 of the EDC2BC message
23) Inhibits Boost pressure gradient monitor
The boost pressure is switched to the default value
P0237
The boost pressure sensor is monitored by hardware The sensor raw voltage value BPSCD_uRawVal is The sensor raw voltage value BPSCD_uRawVal is 2.70bar.
0 4 MIN 1 4 Signal too low Turbocharg er/Supercharger Boost Sensor "A" Continuously Defect condition fulfilled continuosly > 500.0 ms Healing condition fullfilled continuosly > 2000.0 ms Sensor defective or short circuit to ground. Check wiring or replace sensor.
for electric failure. below 337.24mV. above 337.24mV
Circuit Low
Further reactions according to FIDs
At engine start (engine not turning) the difference The boost pressure is switched to the default value
P0236 The plausibility of boost pressure sensor value is - engine is not running
between Boost Pressure and Ambient Pressure is 2.70bar. Difference of ambient and boost pressure is out of Check ambient and boost pressure sensor for
0 12 NPL 3 12 Signal not plausible Turbocharg er/Supercharger Boost Sensor "A" checked by comparing its value with ambient pressure - no failure on boost pressure sensor or atmospheric Defect condition fulfilled continuosly > 2000.0 ms No plausibility error is present Healing condition fullfilled continuosly > 1000.0 ms
outside of plausibility window (-200.00hPa to range. accuracy.
Circuit Range/Performance value when engine is not running.. pressure sensor already detected
200.00hPa). Further reactions according to FIDs
1) indicates operating point, when failure occured
1) Eng_nAvrg __n_DLen2 1) average engine speed 2) indicates operating point, when failure occured
2) InjCtl_qSet__q_DLen1 2) fuel mass set value 3)
3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands 4)
4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 5) indicates if battery voltage was extraordinare which could be 1) Fid_FrmMngBatt 1) Transfers the default value 0xFE00 as battery voltage in byte7+8 of CAN-frame VehPow.
The measured raw value is output.
P0563 This faultpath performs static monitoring (signal range The battery sensor raw voltage (BattCD_uRaw) is The battery sensor raw voltage (BattCD_uRaw) is 5) BattCD_u__uBatt_DLen2 5) Battery voltage the reason for the defect detection 2) Fid_PFltPlausTemp 2) Inhibits plausibility check of filter temperature during cold start
BattCD Battery voltage fault 126 65574 3 Battery voltage non MAX 0 3 Signal too high Continuously Defect condition fulfilled continuosly > 1000.0 ms Healing condition fullfilled continuosly > 480.0 ms Alternator voltage governor defect Replace alternator governor device or alternator 2 2 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp ON Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3
System Voltage Hig h check) of the battery voltage. above 4.61V below 4.61V. 6) CoEng_stEng__OneToOne_DLen1 6) current engine state 6) 3) Fid_PFltVltgBatt 3) Inhibits use of battery voltage value
Further reactions according to FIDs
7) Eng_tStrt__t_DLen1 7) engine starting temperature 7)
8) CTSCD_tClnt__t_DLen1 8) Coolant temperature 8) indicates engine temperature (low or very high temp can
9) IATSCD_tAir__t_DLen1 9) intake air temperature indicate ambient temp problem of relay)
9)
The measured raw value is output. Battery defect, alternator defect, wiring problems (too
P0562 This faultpath performs static monitoring (signal range The battery sensor raw voltage (BattCD_uRaw) is The battery sensor raw voltage (BattCD_uRaw) is
0 4 MIN 1 4 Signal too low Continuously Defect condition fulfilled continuosly > 1000.0 ms Defect condition fulfilled continuosly > 480.0 ms high resistance) or ECU defect. Occurence possible Replace battery or alternator. Check ECU and wiring.
System Voltage Low check) of the battery voltage. below 894.43mV above 894.43mV
Further reactions according to FIDs during cold start.
1) indicates operating point, when failure occured
A power reduction due to turbo charger protection (via 1) Eng_nAvrg __n_DLen2 1) average engine speed
This fault path indicates that a power reduction due to 2) indicates operating point, when failure occured
limiting torq ue TrbCh_trqInrBstPrtLim) is active 2) InjCtl_qSet__q_DLen1 2) fuel mass set value
turbo charger protection is currently active which limits 3)
causing: 3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands
the engine torq ue. In other words, this fault path is not No actions necessary due to this failure alone. 4)
1) A torq ue limitation greater than 25.00% of the 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity)
used as an actual error status indicating a real defect If power reduction occurred due to actual defect, the 5) indicates if battery voltage was extraordinare which could be
Info: Torq ue Monitoring is only active if engine speed is above momentarily allowed maximum torq ue 5) BattCD_u__uBatt_DLen2 5) Battery voltage 1) Fid_FrmMngInfoStatus5 1)
BstPrtTrqLim Info torq ue limitation: turbo charg er protection active 39E 196766 4 non MIN 1 4 Torque Limitation NO CODE IN DATASET but is used more for information purposes for service Defect condition fulfilled continuosly > 60000.0 ms No Healing possible (disabled by Data Set) infinite None except FIDs Active power redcution due to turbo charger protection. failure triggering the torq ue limitation should also be 2 2 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp ON Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3 the reason for the defect detection
Limitation active 500.00rpm. 6) BPSCD_pFltVal__p_DLen1 6) filtered value of boost pressure.
personnel to determine the exact cause of the power in the failure memory. 6)
OR 7) AFSCD_mAirPerCyl__mAirCyl_DLen1 7) value of airmass per cylinder
limitation (in case a real defect evokes a power Follow troubleshooting of this root error. 7) Indicates if air mass flow measurement is in plausible range
8) IATSCD_tAir__t_DLen1 8) intake air temperature
reduction the trig gering failure also has to be present 8)
2) A high idle (EISGov) torq ue limitation greater than 9) CoEng_stEng__OneToOne_DLen1 9) current engine state
in the failure memory). 9)
5.00%.
CAN message DM1DCU (Diagnostic Message #1) - ECU running for at least 6.00s No DM1DCU single message or BAM (Broadcast
which is sent from the Urea Dosing Control Unit - engine is stopped or is running at least 6.00s announce message for mulitple DM1DCU packets) is
U010E (DCU) to the EDC reports errors detected by DCU - battery voltage > 10.01V including 1000.00ms waiting received within 5.00s OR
FrmMngTODM1DC
Message DM1DCU timeout 1A5 65701 2 CAN Bus non MAX 0 2 CAN timeout Dosing control unit (Reductant Metering Control and lamp request status from DCU. time after voltage is above threshold, the first packet is not received within 250.00ms after Defect condition fulfilled continuosly > 30000.0 ms DM1DCU message is received Defect condition
UIv
Unit) - No function - CAN is not in the bus-off state including a waiting the BAM OR
CAN messages received by ECU are monitored for time of 1000.00ms after bus is on again the time interval between receiving multiple DM1
timeout. - ECU is not in the afterrun state. packets is longer than 250.00ms.
1) indicates operating point, when failure occured
2) indicates operating point, when failure occured
3)
1) Eng_nAvrg __n_DLen2 1) average engine speed 4)
Monitoring for reception timeout errors of the CAN
2) InjCtl_qSet__q_DLen1 2) fuel mass set value 5) indicates if battery voltage was extraordinare which could be
message TSC1VEPasIv which is sent from the Vehicle - ECU running for at least 6.00s
3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands the reason for the defect detection
Control Module or Body Computer (VCM/BC) to the - engine is stopped or is running at least 6.00s CAN controller of the EDC reports a reception timeout
Defective CAN controller of Vehicle Control Module or Check presence and correct connection of the 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 6)
EDC to request a torq ue/speed control while the - battery voltage > 10.01V including 1000.00ms waiting for the VCM/BC message TSC1VEPasIv over Default values for TSC1-VE message content used
FrmMngTOTSC1VE No timeout error is reported by the CAN controller over Body Computer , undervoltage of VCM/BC, missing VCM/BC to the network, Check correct functioning of 5) BattCD_u__uBatt_DLen2 5) Battery voltage 7) Check if disturbed CAN communication could have led to this
Timeout of CAN message TSC1-VE passive 3C8 196808 2 CAN Bus non MAX 0 2 CAN timeout NO CODE IN DATASET override control mode state is inactive (slow time after voltage is above threshold, 200.00ms including an additional 800.00ms due to a Defect condition fulfilled continuosly > 800.0 ms Immediate 2 2 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp ON Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3
PasIv 500.00ms VCM/BC, CAN cable connecting the VCM/BC is the VCM/BC CAN controller and its voltage supply. 6) NetMng_stCANA__OneToOne_DLen1 6) Status of CAN A failure. Not that the monitoring of this error is disabled if only one
recognition of time out) - CAN is not in the bus-off state including a waiting longer CAN receiving cycle time because of an Further reactions according to FIDs
disconnected or broken. Short circuit in wiring. Check wiring. 7) NetMng_stCANB__OneToOne_DLen1 7) Status of CAN B CAN controller is in the bus-off state.
time of 1000.00ms after bus is on again inactive override control mode.
8) NetMng_stCANC__OneToOne_DLen1 8) Status of CAN C 8) Check if disturbed CAN communication could have led to this
CAN messages received by ECU are monitored for - ECU is not in the afterrun state.
9) CTSCD_tClnt__t_DLen1 9) Coolant temperature failure. Not that the monitoring of this error is disabled if only one
timeout.
CAN controller is in the bus-off state.
9) indicates engine temperature (low or very high temp can
indicate ambient temp problem of relay)
1) Activates torq ue limit CoEng_trq LimErr_CUR, and enables further curves 2,3,4 (main
1) indicates operating point, when failure occured torq ue limit switch)
1) Fid_CoEng_trq LimErr
2) indicates operating point, when failure occured 2) Activates limit CoEng_trq LimErr3_CUR only in addition to Fid_CoEngTrqLimErr_mp.
2) Fid_CoEng_trq LimErr3
1) Eng_nAvrg __n_DLen2 1) average engine speed 3) 3) Transfers engine degradation level 1 of the EDC2BC message
The monitoring is only active if 3) Fid_FrmMngEngDgrtLvl1Iv
2) InjCtl_qSet__q_DLen1 2) fuel mass set value 4) 4) Transfers engine degradation level 3 of the EDC2BC message
- the high pressure governor is operating in closed 4) Fid_FrmMngEngDgrtLvl3Iv
The rail pressure is monitored by various fault paths The negative rail pressure governor deviation Metering unit stuck in open position, zero-delivery 3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands 5) 5) Reduces max engine high idle speed limit, to HIGov_nSysDgrt3SetPoint_C
loop control (Rail_stCtlLoop=5) 5) Fid_HIGovSysDgrt3
during active pressure control by the metering unit. (Rail_pDvt) is below the engine speed dependent limit throttle clogged, metering unit without power due to 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 6) Measuring value which evokes the setting of the Min and Sig 6) Inhibits high pressure test
- the engine is not in overrun (CoEng_stOvrRun.0=0) 6) Fid_HpTst 1) yes (technical) because of Fid_CoEng_trq LimErr
Fuel high pressure pump is at minimum delivery and Fuel pressure P0088 The fault path at hand detects an excessive negative from curve Rail_pMeUnDvtMin AND electricel error. 5) CoEng_stEng__OneToOne_DLen1 5) current engine state error if it exceeds the pressure limit 7) Inhibits the monitoring of leakage detection by quantity balance
RailMeUn2 153 65619 3 non MAX 0 3 Rail pressure too high - the fuel system temperature (FlSys_t) is above Defect condition fulfilled continuosly > 2500.0 ms No Healing possible (disabled by Data Set) Infinite None except FIDs. Check for defects according to 'reason of failure' list. 3 3 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp BLINK Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3 7) Fid_RailMeUn10Blk 2) yes (technical) because of Fid_CoEng_trq LimErr3
the Rail pressure is not reducing (Rail) control Fuel Rail/System Pressure - Too Hig h rail pressure governor deviation (too high rail the rail pressure governor setpoint value of the fuel Low pressure side: Pressure before gear pump too 6) RailCD_pPeak__RailPres_DLen2 6) maximum rail pressure of last 10ms 7) indicates engine temperature (low or very high temp can 8) Inhibits the monitoring of positive governor deviation and rail pressure governing set
29.96°C 8) Fid_RailMeUn12Blk
pressure) at zero delivery of fuel volume flow through volume flow (Rail_dvolMeUnSet) is below - high (e.g. by pressure relieve valve), pressure after 7) CTSCD_tClnt__t_DLen1 7) Coolant temperature indicate ambient temp problem of relay) value(volume flow)
- the current injection quantity (InjCtl_qSetUnBal) is 9) Fid_RailMeUn1Blk
the metering unit. 100.00mm3/s. zero-delivery throttle too high. 8) BattCD_u__uBatt_DLen2 8) Battery voltage 8) indicates if battery voltage was extraordinare which could be 9) Inhibits the monitoring of positive governor deviation and setpoint of the fuel volume flow
above 0.00mg/cyc and the monitoring has not been 10) Fid_RailMeUn6Blk
9) FTSCD_tFuel__t_DLen1 9) Fuel temperature the reason for the defect detection through the metering unit
inhibited by other faults (Fid_RailMeUn2Blk.0=1). 11) Fid_RailMeUn7Blk
9) indicates engine temperature (low or very high temp can 10) Inhibits the monitoring of rail pressure drop rate in overrun
12) Fid_RailSysDgrt3
indicate ambient temp problem of relay) 11) Inhibits the monitoring of metering unit set value in overrun
12) Maximum rail pressure setpoint Rail_pSysDgrt3SetPoint_C is active
1) Activates torq ue limit CoEng_trq LimErr_CUR, and enables further curves 2,3,4 (main
1) indicates operating point, when failure occured
torq ue limit switch)
2) indicates operating point, when failure occured 1) Fid_CoEng_trq LimErr
2) Activates limit CoEng_trq LimErr3_CUR only in addition to Fid_CoEngTrqLimErr_mp.
1) Eng_nAvrg __n_DLen2 1) average engine speed 3) 2) Fid_CoEng_trq LimErr3
3) Transfers engine degradation level 3 of the EDC2BC message
The monitoring is only active if the high pressure 2) InjCtl_qSet__q_DLen1 2) fuel mass set value 4) 3) Fid_FrmMngEngDgrtLvl3Iv
The rail pressure drop during overrun is above a 4) Reduces max engine high idle speed limit, to HIGov_nSysDgrt3SetPoint_C
governor is operating in closed loop control 3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands 5) 4) Fid_HIGovSysDgrt3
maximum limit. 5) Inhibits high pressure test
The rail pressure is monitored by various fault paths (Rail_stCtlLoop=5) the engine is in overrun condition Leakage in the high pressure section, injection nozzle 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 6) Measuring value which evokes the setting of the Min and Sig 5) Fid_HpTst
This pressure limit is calculated from the rail pressure 6) Inhibits the monitoring of leakage detection by quantity balance 1) yes (technical) because of Fid_CoEng_trq LimErr
Fuel pressure P0093 during active pressure control by the metering unit. (CoEng_stOvrRun.0=1), the fuel injection quantity is stuck in open position, worn high pressure pump, worn 5) CoEng_stEng__OneToOne_DLen1 5) current engine state error if it exceeds the pressure limit 6) Fid_RailMeUn10Blk
RailMeUn6 Rail pressure drop rate during overrun too high 156 65622 3 non MAX 0 3 Rail pressure drop high at the last funciton call (t-20ms) minus the maximum Defect condition fulfilled continuosly > 2500.0 ms No Healing possible (disabled by Data Set) Infinite None except FIDs. Check for defects according to 'reason of failure' list. 2 2 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp ON Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3 7) Inhibits the monitoring of positive governor deviation and rail pressure governing set 2) yes (technical) because of Fid_CoEng_trq LimErr3
(Rail) control Fuel System Leak Detected – Large Leak The fault path at hand detects if the rail pressure zero, the setpoint value of the fuel volume flow through injector, leaking pressure relieve valve, injector reflux 6) RailCD_pPeak__RailPres_DLen2 6) maximum rail pressure of last 10ms 7) indicates engine temperature (low or very high temp can 7) Fid_RailMeUn12Blk
admissible pressure drop determined from curve value(volume flow)
decreases faster during overrun than expected the metering valve is equal or below -100.00mm3/s too high. 7) CTSCD_tClnt__t_DLen1 7) Coolant temperature indicate ambient temp problem of relay) 8) Fid_RailMeUn1Blk
Rail_dpDecMonMax [hPa/s] multiplied by the function 8) Inhibits the monitoring of positive governor deviation and setpoint of the fuel volume flow
and the monitoring has not been inhibited by other 8) BattCD_u__uBatt_DLen2 8) Battery voltage 8) indicates if battery voltage was extraordinare which could be 9) Fid_RailMeUn2Blk
call cycle (20ms). through the metering unit
faults (Fid_RailMeUn6Blk.0=1) 9) FTSCD_tFuel__t_DLen1 9) Fuel temperature the reason for the defect detection 10) Fid_RailMeUn7Blk
9) Inhibits the monitoring of negative governor deviation at zero delivery
9) indicates engine temperature (low or very high temp can 11) Fid_RailSysDgrt3
10) Inhibits the monitoring of metering unit set value in overrun
indicate ambient temp problem of relay)
11) Maximum rail pressure setpoint Rail_pSysDgrt3SetPoint_C is active
1) Activates torq ue limit CoEng_trq LimErr_CUR, and enables further curves 2,3,4 (main
1) indicates operating point, when failure occured torq ue limit switch)
1) Fid_CoEng_trq LimErr
2) indicates operating point, when failure occured 2) Activates limit CoEng_trq LimErr3_CUR only in addition to Fid_CoEngTrqLimErr_mp.
2) Fid_CoEng_trq LimErr3
1) Eng_nAvrg __n_DLen2 1) average engine speed 3) 3) Transfers engine degradation level 3 of the EDC2BC message
3) Fid_FrmMngEngDgrtLvl3Iv
2) InjCtl_qSet__q_DLen1 2) fuel mass set value 4) 4) Reduces max engine high idle speed limit, to HIGov_nSysDgrt3SetPoint_C
The monitoring is only active if the high pressure 4) Fid_HIGovSysDgrt3
Hig h pressure system: Leakage in the high pressure 3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands 5) 5) Inhibits high pressure test
The rail pressure is monitored by various fault paths governor is operating in closed loop control The setpoint value of the rail pressure governor for the 5) Fid_HpTst
section, injection nozzle stuck in open position, worn or 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 6) Measuring value which evokes the setting of the Min and Sig 6) Inhibits the monitoring of leakage detection by quantity balance
during active pressure control by the metering unit. (Rail_stCtlLoop=5), fuel volume flow through the metering unit exceeds an 6) Fid_RailMeUn10Blk
Fuel pressure Metering unit position P0089 defective high pressure pump, worn injector, leaking 5) CoEng_stEng__OneToOne_DLen1 5) current engine state error if it exceeds the pressure limit 7) Inhibits the monitoring of positive governor deviation and rail pressure governing set
RailMeUn7 Setpoint of metering unit in overrun mode not plausible 157 65623 3 non MAX 0 3 The fault path at hand detects an excessive leakage of the engine is in overrun condition upper limit during overrun. This limit is interpolated Defect condition fulfilled continuosly > 2500.0 ms No Healing possible (disabled by Data Set) Infinite None except FIDs. Check for defects according to 'reason of failure' list. 2 2 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp ON Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3 7) Fid_RailMeUn12Blk
(Rail) control abnormal Fuel Pressure Regulator 1 Performance pressure relieve valve. Low pressure system: 'Zero 6) RailCD_pPeak__RailPres_DLen2 6) maximum rail pressure of last 10ms 7) indicates engine temperature (low or very high temp can value(
fuel by monitoring the setpoint value of the fuel volume (CoEng_stOvrRun.0=1), the fuel injection quantity is from the rail pressure dependent curve 8) Fid_RailMeUn1Blk
delivery' is not active in metering unit (excessve 7) CTSCD_tClnt__t_DLen1 7) Coolant temperature indicate ambient temp problem of relay)
flow through the metering unit during overrun. zero and the monitoring has not been inhibited by other Rail_dvolMeUnOvrRun [mm^3/s]. 9) Fid_RailMeUn2Blk
leakage in metering unit). 8) BattCD_u__uBatt_DLen2 8) Battery voltage 8) indicates if battery voltage was extraordinare which could be
faults (Fid_RailMeUn7Blk.0=1). 10) Fid_RailMeUn6Blk
9) FTSCD_tFuel__t_DLen1 9) Fuel temperature the reason for the defect detection
11) Fid_RailMeUn7Blk
9) indicates engine temperature (low or very high temp can
12) Fid_RailSysDgrt3
indicate ambient temp problem of relay)
Following conditions must be satisfied Downstream
catalyst temperature intact and Intake air temperature If the ambient temperature sensor is inaccurate it is
The temperature sensors downstream and upstream of
IATSCD_tAir > -10.04°C likely that the urea pump module (DTC $E4) and urea
the SCR-catalyst together with the ambient
Check is only done if all sensors ok (ambient + tank temperature (DTC $E5) are also reported
temperature signal are checked for static plausibiltiy
Ambient Temperature of P0426 - downstream catalyst temperature sensor not defective upstream+downstream): Ambient temperature sensor or both upstream and implausible by the DCU. Check wiring and signal of
against each other (MAX, MIN and SIG failure). This
0 2 SIG 2 2 Humidity Sensor or both Catalyst Temperature Sensor Circuit - the time since engine start (CoEng_tiNormal) has Failure is detected if Defect condition fulfilled continuosly > 1000.0 ms Temperature are plausible Healing condition fullfilled continuosly > 500.0 ms None except FIDs. downstream catalyst temperature sensors are temperature sensors. Ensure complete cool down of
is done once for each driving cycle and only during
Cat Range/Performance not exceeded 1000.00ms, T_dwnstr - T_upstr < 999.96°C (both in range) AND inaccurate, defect in wiring (also check connectors). vehicle (>10 hours) without sun exposure and and
cold start when all temperatures should still be the
- the vehicle stand still time is greater than 10.00h and T_dwnstr - T_amb > 999.96°C measure all 3 sensors sig nals. If temperature
same. Depending on the availibility/defectiveness of the
- the difference between current engine temperature differences are above 20°C replace the sensors which
temperature sensors the plausibility check can vary.
and the temperature during the last afterrun exceeds seem implausible.
50.00K.
This function monitors the Urea quality. - After reagent tank refill is detected
P2BA9 As no reagent quality sensor is installed, the - Urea injection is active and in closed loop The leading failure (Fid_SCRCatRdcAgHiQlDetActv) Possible wrong fluid (e.g.too high concentration urea)
0 4 MIN 1 4 Immediate None According to FIds Check and replace the fluid in the Urea tank.
NOx Exceedence - Insufficient Reagent Quality determination is done indirectly by evaluating NOx - monitor is not inhibited by another failure is healed. is in the Urea tank.
closed loop control behaviour after a reagent refill. (Fid_SCRCatRdcAgQlDetActv not inhibited)
1) indicates operating point, when failure occured
1) Eng_nAvrg __n_DLen2 1) average engine speed 2) indicates operating point, when failure occured
2) InjCtl_qSet__q_DLen1 2) fuel mass set value 3)
The failure is part of the SCR Driver's inducement. If a 3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands 4)
After this Warning Level is triggered by Fid
SCR-relevant failure occurs the driver inducement is This failure is used to activate a warning lamp / 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 5) 1) Fid_CoVehPrflm21OBD 1) Activation of performance limiter step 2.1
(Fid_SCRCatWarnLvl1_mp) the engine is running for
Urea Quality or urea started. After a certain distance or engine running time If the leading failure is no more active (healed), this message or an engine derate (Performance Limiter). This is not a standalone failure, this failure is triggered 5) CoEng_stEng__OneToOne_DLen1 5) current engine state 6) indicates if battery voltage was extraordinare which could be 2) Fid_SCRCatWL3Blk1 2) Sets strong Warning status for Status Block 1 1) yes (OBD) because of Fid_CoVehPrflm21OBD
SCRCatWarnLvl1 urea quality and urea warning level 1 4AA 262314 4 Inducements non MIN 1 4 NO CODE IN DATASET Continuously longer than 90.00min or driven for a distance > Defect condition fulfilled continuosly > 100.000 ms Healing condition fullfilled continuosly > 100.000 ms Check and repair leading failure. 4 1 no Reset 0 not visible for OBD-Tester 0 SysLamp OFF Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3
level error 1 with the SCR-relevant failure active, this failure is set. failure will also disappear. by another failure via Fid_SCRCatWarnLvl1_mp. 6) BattCD_u__uBatt_DLen2 6) Battery voltage the reason for the defect detection 3) Fid_HIGovSysDgrt1 3) Reduces max engine high idle speed limit, to HIGov_nSysDgrt1SetPoint_C.
SCRCAT_LTHRESWARNLVL_C NOT FOUND IN
This inducement warning level is triggered by FId Reactions according to calibrated FIDs. 7) CTSCD_tClnt__t_DLen1 7) Coolant temperature 7) indicates engine temperature (low or very high temp can
LOADED LABELS!.
(Fid_SCRCatWarnLvl1_mp). 8) SCRCat_tEstIv__t_DLen2 8) Estimated catalyst temperature indicate ambient temp problem of relay)
9) IATSCD_tAir__t_DLen1 9) intake air temperature 8)
9)
1) Activates torq ue limit CoEng_trq LimErr_CUR, and enables further curves 2,3,4 (main
1) indicates operating point, when failure occured
torq ue limit switch)
The starter motor is activated and deactivated by both a 2) indicates operating point, when failure occured
1) Eng_nAvrg __n_DLen2 1) average engine speed 2) Transfers engine degradation level 1 of the EDC2BC message
high side (HS) switch (BTS 452 R) and a low side 3)
2) InjCtl_qSet__q_DLen1 2) fuel mass set value 1) Fid_CoEng_trq LimErr 3) Switches off high side and low side of the starter powerstages. No starting possible, state
(LS) power stage (CJ945) for savety reasons. This 4)
3) VehDa_stTrqDem__WToB1_DLen2 3) state of active torq ue demands 2) Fid_FrmMngEngDgrtLvl1Iv 1 error( HS and LS power stage are switched ON)
diagnostic function monitors the LS power stage (PS) 5)
Both HS and LS Powerstage are automatically 4) VSSCD_v__v_DLen1 4) vehicle speed (velocity) 3) Fid_StrtRlyState1_MAX (only for MAX failure) 4) Switches off high side and low side of the starter powerstages. No starting possible, state
for short circuit to battery (SCB) and ground (SCG), 6) indicates if battery voltage was extraordinare which could be
Starter crank relay electrical failure (Low Side power Short to Battery or P2671 This error can only be detected when both power LS power stage hardware reports 'short circuit to switched off. Short circuit of wiring to external source or inside 5) CoEng_stEng__OneToOne_DLen1 5) current engine state 4) Fid_StrtRlyState1_MIN (only for MIN failure) 1 error( HS and LS power stage are switched ON) 1) yes (technical) because of Fid_CoEng_trq LimErr
StrtCDLS 2E1 131297 3 Starter control non MAX 0 3 excess temperature and open load. The PS monitoring Defect condition fulfilled continuosly > 100.0 ms No Healing possible (disabled by Data Set) Infinite Check wiring or replace relay. 2 2 Reset on Init or Restart 0 not visible for OBD-Tester 0 SysLamp ON Mil OFF driving cycle 0 driving cycle 0 warm up cycle 40 warm up cycle 40 same as in DLC 3 the reason for the defect detection
stage) excess temperature Actuator Supply Voltage "B" Circuit Hig h stages (High side and Low side) are activated battery' or 'excess temperature'. relay. 6) BattCD_u__uBatt_DLen2 6) Battery voltage 5) Fid_StrtRlyState2_MAX (only for MAX failure) 5) Switches off low side of the starter powerstage. No starting possible. state 2 error ( HS
cannot differentiate between SCB and excess 7) Status of terminal 15. Immobilzer error should normally be
Further reactions according to FIDs 7) T15CD_stRawVal__OneToOne_DLen1 7) raw value of Terminal 15 6) Fid_StrtRlyState2_MIN (only for MIN failure) power stage is switched ON and LS power stage is switched OFF)
temperature defects. Both these defects can only be detected while starting the engine (status T15=1)
8) Eng_tStrt__t_DLen1 8) engine starting temperature 7) Fid_StrtRlyState2_SIG (only for SIG failure) 6) Switches off low side of the starter powerstage. No starting possible. state 2 error ( HS
detected if both PS are switched on. A SCG and open 8)
9) T15CD_stRawVal__OneToOne_DLen1 9) raw value of Terminal 15 power stage is switched ON and LS power stage is switched OFF)
load defect, on the other hand, can only be detected if 9) Status of terminal 15. Immobilzer error should normally be
7) Switches off low side of the starter powerstage. No starting possible. state 2 error ( HS
the HS PS is on and the LS PS is switched off. detected while starting the engine (status T15=1)
power stage is switched ON and LS power stage is switched OFF)