0% found this document useful (0 votes)
11 views

Filter Cart

Uploaded by

Hanzil Hakeem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views

Filter Cart

Uploaded by

Hanzil Hakeem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

54

FC
Filter Cart
A fully self-contained mobile solution
for bulk oil handling, fluid transfer and
reservoir or gearbox conditioning.
Ideal for lower viscosity hydraulic oil, lube
oil and diesel fuel.

hyprofiltration.com/
Engineered for industrial use.
Rugged construction and attention to the smallest of
details come together remarkably so that nothing holds
55
you or your equipment back. The easy to maneuver hand-
truck style design with never-flat pneumatic tires and
cast iron gear pump with internal relief mean you get
powerful filtration exactly when and where you need it.

Set the stage for your success.


Staged filtration allows a range of media selections for
particulate and water removal to deliver ISO Codes right on
target. Choose between dual MF110 cartridge (standard) or
up to four Spin-On elements to tackle the most viscous fluids
and achieve unimaginably low ISO Codes in a single pass.

Media matters.
DFE rated filter elements stay true to efficiency ratings
and ensure the highest level of particulate capture and
retention capabilities. And with media options down
to β3[C] ≥ 4000, you can be sure contamination stays
exactly where you want it: out of your systems.

Your standard Filter Cart, reimagined.


Sample ports in the right locations arm you with access to
consistently accurate system conditions which is why every
FC comes standard with up- and downstream sample ports
in their proper positions. And with the 35’ (11m) retractable
cord reel or 35’ air hose for pneumatic models, it’s easy
to see why the standard FC isn’t so standard after all.

With options to make your job easier.


With the optional filter bypass line, cold starts, gearbox
pump-outs, and even element change outs become easier
than ever. Add the optional PM-1 particle monitor for
real time cleanliness data and know exactly how your
filtration is performing without the need for a bottle.

Completely customizable.
The FC comes in a variety of flow rates and with electric
options that range from 120 to 575 V ac, single or three
phase. Or choose the pneumatic and explosion proof models
to take your filtration into hazardous zones like you never
thought possible. Even color coordinate each FC to your
existing safety standards. With thousands of combinations to
choose from, the possibilities are endless for what you can
do with the FC.
56 FC Specifications
Dimensions1 Height Width Depth Weight
45” (114 cm) 20” (50 cm) 23” (58 cm) 125 lbs (57 kg)

Connections Inlet Outlet Hoses


FC05-FC5: 1” male JIC (37° flare) FC05-FC10 1” male JIC (37° flare) FC05-FC5: 1” x 10 ft (2.4 m)
FC10: 1.25” male JIC (37° flare) FC20: 1.25” male JIC (37° flare) FC10: 1.25” x 10 ft (2.4 m) suction
FC20: 1.5” male JIC (37° flare) 1” x 10 ft (2.4 m) discharge
FC20: 1.5” x 10 ft (2.4 m) suction

Operating Fluid Temperature Ambient Temperature


30°F to 225°F -4°F to 104°F
Temperature (0°C to 105°C) (-20C to 40C)

ΔP Indicator 22 psi (1.5 bar). Consult factory for other options.

Trigger
Filter 25 psid (1.7 bard). Consult factory for other options.

Assembly
Bypass
Materials of Frame Filter Assembly Hoses Wands Element
Industrial Aluminum head & canister Reinforced synthetic Stainless Steel Bypass Valve
Construction coated steel Nylon

Electric Motor TEFC, 56-215 frame


0.5-3 hp, 1450-1750 RPM

Motor Starter MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.

Electric Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel
included. NEMA 5-15 plug installed on Power Option 12.
Connection Voltages over 230 V ac: 35’ (11 m) power cord included.

Pump Cast iron, positive displacement gear pump with internal relief. Maximum pressure
on pump inlet 15 psi (1 bar). Consult factory for higher pressures.

Pump Bypass Full bypass at 150 psi (10 bar)2

Pneumatic ~40 cfm @ 80 psi3


35’ (11 m) retractable air hose included when pneumatic option selected (replaces electric cord reel).
Option Air
Consumption
Media M A W
G8 Dualglass, our latest generation G8 Dualglass high performance Stainless steel wire mesh
Description of DFE rated, high performance glass media combined with water removal media βx[C] ≥ 2 (βx ≥ 2)
media for all hydraulic & lubrication scrim. βx[C] ≥ 4000 (βx ≥ 200)
fluids. βx[C] ≥ 4000 (βx ≥ 200)

Replacement To determine replacement elements, use corresponding codes from your equipment part number:
Model Filter Element Part Number Example
Elements Standard FC (2x MF110 11” bowls) HP110NL11 – [Media Selection Code] [Seal Code] HP110NL11-12MV
Special Option D1 HP75L8 – [Media Selection Code] [Seal Code] HP75L8-25MB

Viscosity 2-5000 cSt 4

Fluid Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility
with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from
Compatibility special options.

Hazardous Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D.
Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included.
Environment
Options
1
Dimensions are approximations taken from base model and will vary according to options chosen.
2
10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life
and/or cause premature pump failure.
3
Air consumption values are estimated maximums and will vary with regulator setting.
4
When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.

hyprofiltration.com/
FC Part Number Builder 57

FC - -
Flow Rate Power Options Hose Special Media 1 Media 2 Seal
Connection Options

Flow Rate1 05 0.5 gpm (1.7 lpm)


1 1 gpm (3.7 lpm)
2 2 gpm (7.5 lpm)
5 5 gpm (18.9 lpm)
10 10 gpm (37.9 lpm)
202 20 gpm (75.7 lpm)

Power 60 Hz, 1750 RPM 50 Hz, 1450 RPM Pneumatic


12 120 V ac, 1P 11 110 V ac, 1P 00 Pneumatically driven air motor & PD
Options 22 208-230 V ac, 1P 21 220 V ac, 1P pump. FRL & flow meter included.
Contact factory 23 208-230 V ac, 3P 40 380-440 V ac, 3P
for options 46 460-480 V ac, 3P 52 525 V ac, 3P
not listed 57 575 V ac, 3P

Explosion proof - Class 1, Division 1, Group C+D per NEC 501 – Ready for outdoor use
X__ Add X prefix to power option listed above. Not available with (00) Pneumatic Option

Hose G Female BSPP swivel hose ends, no wands


S Female JIC swivel hose ends, no wands
Connection W Female JIC swivel hose ends, with wands

Special B Complete filter bypass line K HP75L8-149W Spin-On suction strainer (Can’t be paired with K option)
C CE marked for machinery safety directive 2006/42/EC M Total system flow meter (120 cSt max)
Options D13 2 x S75DL8 filter assemblies in series O On-board PM-1 particle monitor & clean oil indicator light
D3 True differential pressure gauge, visual green to red P94 Phosphate ester fluid compatibility modification
E 100 mesh cast iron basket strainer (Can’t be paired with K option) S95 Skydrol fluid compatibility modification
H1 10’ (3 m) return line hose extension U CUL and/or CSA marked starter enclosure for Canada
H2 20’ (6 m) return line hose extension Z On site start-up training
J Add pressure gauge between pump & filter assembly

Media G8 Dualglass G8 Dualglass + water removal Stainless wire mesh


1M β3[C] ≥ 4000 3A β4[C] ≥ 4000 25W 25μ nominal
Selection 3M β4[C] ≥ 4000 6A β6[C] ≥ 4000 40W 40μ nominal
6M β6[C] ≥ 4000 10A β11[C] ≥ 4000 74W 74μ nominal
10M β11[C] ≥ 4000 25A β22[C] ≥ 4000 149W 149μ nominal
16M β16[C] ≥ 4000
25M β22[C] ≥ 4000

Seals B Nitrile (Buna)


V Fluorocarbon
E-WS6 EPR seals + stainless steel support mesh

1
Nominal flow rates at 60 Hz motor speeds.
2
Contact factory for sizing assistance on all viscosities.
3
Replaces standard MF110 housings.
4
When selected, must be paired with Seal option “V.” Contact factory for more information or assistance in fluid compatibility.
5
When selected, must be paired with Seal option “E-WS.” Contact factory for more information or assistance in fluid compatibility.
6
Only available in 3M media for HP75L8 series elements.
For all up to date option details and compatibilites, please reference our Contamination Solutions Price List or contact customer service.

hyprofiltration.com/

You might also like