Data Sheet VA500 EN
Data Sheet VA500 EN
Special features:
NEW:
As option, integrated • Including temperature measurement, optional: pressure measurement
pressure sensor
• RS 485 interface, Modbus-RTU as standard
• Integrated display for m³/h and m³
• Applicable from 1/2” to DN 1000
• Easy installation under pressure
• 4...20 mA analogue output for m³/h or m³/min
• Pulse output for m³ or M-Bus (optional)
• Inner diameter adjustable by means of keys
Bewegliches • Flow meter can be reset
Montagegewinde • Adjustable by means of keypad on the display: Reference conditions, °C and mbar,
G 1/2″ 4...20 mA scaling, pulse weight
Sicherungsring
Ø 11,7 mm
The sensor can be removed Analogue output: 4…20 mA for m³/h or l/min
during operation and cleaned if Pulse output: 1 pulse per m³ or per litre electrically
necessary. isolated. Pulse weight can be set on the
display. Alternatively, the pulse output
can be used as an alarm
Supply: 18…36 VDC, 5 W
Burden: < 500 Ω
Housing: Polycarbonate (IP 65)
Sensor tube: Stainless steel, 1.4301
Installation length 220 mm, Ø 10 mm
Mounting thread: G 1/2″, 1/2″ NPT male thread
Ø housing: 65 mm
Mounting position: any
82 www.cs-instruments.com
Flow
Gas type
K1 Compressed air For further accessories refer to pages 106 to 110
K2 Nitrogen (N2)
K3 Argon (Ar)
K4 Carbon dioxide (CO2)
K5 Oxygen (O2)
K6 Nitrous oxide (N2O)
K7 Natural gas (NG)
K8 Helium (He) (real gas adjustment J2 required)
K9 Propane (C3H8) (real gas adjustment J2 required)
K10 Methane (CH4)
K12 Further gas / please indicate gas type (on request)
K13 Gas mixture / please indicate mixture ratio (on request)
www.cs-instruments.com 83
Flow
y
The maximum mounting depth corre-
sponds to the respective probe length.
(Probe length 220 mm = 220 mm max- Safety ring
x
da
imum mounting depth).
84 www.cs-instruments.com