Absolute rotary Encoder

CEV582M*8192/4096 PB (ALT:CEV58M-00239) Order No.:CEV582M-10239


31.8.2021 / 010102058202020201

Technical data

NO.OF STEPS/REV 8.192,000


NO. OF REVOLUTIONS 4.096,000
INTERFACE PROFIBUS DP
SUPPLY VOLTAGE 10-30V
PROTECTION Class IP65
TEMPERATURE RANGE -20+75°C
FLANGE TYPE ZB36/D65
SHAFT TYPE 10FL/19,5
CONNECTOR TYPE 2XM16X1,5/1XM12X1,5
CONNECTOR-POSITION RADIAL
PINOUT NO. TR-ECE-TI-GB-0065
MATING PLUG NO
OPTIONS ENC 12MBAUD
OPTIONS ENC PNO-PROFILE CLASS.2
OPTIONS ENC SUBSTITUTE FOR C_58
DRAWING NO. 04-CEV582M-M0215
FIRMWARE NO 437936
DOCUMENTATION NO DOKUMENTE
AL: N
ECCN: N
MTTFd [y] (T=45°C, DC=0) >= 100
UL-APPROVALS USA+CANADA
6 5 4 3 2 1

56,1 3xM4, 3tief/deep


TKn48`0.2, (3x120°)

(10 )
D D

n10 h7 9,985
(35,975)
n36 f8 35,936
n65

n52

n14
18,9 9

19,4 48,5

~87,2
C 58 C
10

M12x1.5, SW14, für Kabel/for cable n3-6.5 32,8


35,6
41,3
B B
2xM16x1.5, SW21, für Kabel/for cable n8.5-12
Biegeradius Kabel 15xn bezogen auf Standardkabel
Unitronic FD-CP
Bending cable radius 15xn for cabletype
Unitronic FD-CP Artikel-Nr. und Steckerbelegung: siehe Datenblatt
Article-No. and pin connections: see data sheet
TR-Electronic GmbH Maßstab1 : 1 DIN A3
Eglishalde 6
✂ ✂

✂ ✂

✞ ✞

✞ ✞

Zeichungs-Nr. nur für diese Ausführung gültig


✝ ✝

D-78647 Trossingen
✝ ✝

✆ ✆

✆ ✆

☎ ☎

☎ ☎

phone +49 7425 228-0


✄ ✄

✄ ✄

Drawing-No. only für this type valid


✂ ✂

✂ ✂


www.tr-electronic.de
Datum Name
Erstellt 17.06.2020 FLAIG CEV-582-M, 36er Zentr.
A Bearb. 17.06.2020 FLAIG A
Gepr. 17.06.2020 NEMECZ
Norm
www.tr-electronic.de Zeichnungs-Nr.: / Drawing-No.: Blatt
DXF+Info: 1
[email protected] 04-CEV582M-M0215 1 Bl
Zust. Änderungen Datum Name EDV-Nr.: Dok.Art. IDW Teil-Dok. 000 Dok.Vs. 00
6 5 4 3 2 1
Pin assignment

58 / 80 Profibus-DP PNO Class 2


Betriebsanleitung beachten! - Observe User Manual!

X1 Screw clamp 4 pin

Pin 1 Profibus, Data A

Pin 2 Profibus, Data B


Profibus_IN
Pin 3 US, 11-27 V DC

Pin 4 GND, 0V

X2 Screw clamp 4 pin

Pin 1 Profibus, Data A

Pin 2 Profibus, Data B


Profibus_OUT
Pin 3 US, 11-27 V DC

Pin 4 GND, 0V

Print clamp, MKDSN 1,5/ 4-5,08: (not connected clamps must be tightened securely!)
- Nominal current: 13.5 A
- nominal voltage: 250 V
- grid spacing: 5.08 mm
- number of poles: 4
Subject to change

- connection angle: 0°
- nominal cross-section (flexible) max. 1.5 mm²
- nominal cross-section AWG/kcmil max. 16

TR - ELECTRONIC GmbH, Eglishalde 6, 78647 Trossingen, Tel. ++49 (0)7425 / 228-0, Fax ++49 (0)7425 / 228-33
Edition-/Rev.-Date: 11/07/2018 Document-/Rev.-No.: TR-ECE-TI-GB-0065-04 Page 1 of 2
Pin assignment

= ON = OFF = 1 Hz = 10 Hz

BUS FAIL BUS RUN


Cause
(red) (green)

No supply voltage, hardware error

Parameter- or configuration error


(Preset value 1/2 or limit switch out of range, wrong GSD file)
Memory error, position error

Blink mode is supported only in case of older measuring system


generations.
Unrecoverable measuring system defect
(memory error, position error)

No allocation to a master, no data exchange


Betriebsanleitung beachten! - Observe User Manual!

Parameter- or configuration error in PNO compatible target configuration


(number of revolutions is not a power of two)

operational, no error, bus in cycle

General note:

If the measuring system is the last station in the Profibus segment, the DIP switch S3 for the Profibus
terminator (switching-on of the terminal resistance) must be switched on. Otherwise the terminator
must be switched off. With the add-on connection of the terminal resistance the Profibus signals
DataA_OUT and DataB_OUT will be switched off and following slaves are separated from the bus.

The Profibus also operates, if the device is separated from the connection cap, however with one
exception: If the measuring system is the last station in the Profibus segment, the termination
isn't fully active because the reference potential of the terminator resistance is missing!

In order to enable a separate wiring of incoming and outgoing signals the Profibus terminals and the
terminals for the supply voltage have two connection possibilities.

TR-Electronic recommends for the operation to use only bus cables certified by the Profibus User
Organization (PNO).

With the BCD address switches S1 (100) and S2 (101) the station address for the Profibus is set
from 3 to 99.
Subject to change

TR - ELECTRONIC GmbH, Eglishalde 6, 78647 Trossingen, Tel. ++49 (0)7425 / 228-0, Fax ++49 (0)7425 / 228-33
Edition-/Rev.-Date: 11/07/2018 Document-/Rev.-No.: TR-ECE-TI-GB-0065-04 Page 2 of 2