Soln-Cd-Id-Cas-L7-48100 Rev4 L7 Executive Offices Corridor - Setting Out Plan 4
Soln-Cd-Id-Cas-L7-48100 Rev4 L7 Executive Offices Corridor - Setting Out Plan 4
5' EOWD10
NECESSARY INSTALLATIONS AS INDICATED ON DRAWINGS.
6. DIMENSIONS ARE TAKEN FROM THE FINISHED FACE OF WALLS. DIMENSIONS
LOCATING DOORS BY EDGE ARE TO THE INSIDE EDGE OF JAMB, UNLESS
OTHERWISE NOTED.
7. PROVIDE WATER- RESISTANT SUBSTRATE AT ALL SURFACES TO BE EXPOSED TO
WATER AND/ OR TO RECEIVE CERAMIC TILE.
8. CONTRACTOR TO VERIFY SETTING-OUT OF FINISHES ON DRAWINGS AND ON SITE
50
150
WITH DESIGNER (ARCHITECT/INTERIOR) PRIOR TO FINAL LAYING OUT OF FINISHES.
1250 1200 860 1180 1180 1180 1180 1180 860 1180 1180 480 800 1080 1180 860 1095 1195 860 1190 9. CONTRACTOR TO SUBMIT SAMPLE/S OF ALL HARDWARE, ACCESSORIES AND
FINISHES AS SPECIFIED FOR APPROVAL PRIOR TO FULL-PURCHASING.
18040 2000 10. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ITEMS NOT SHOWN IN THE
DRAWING SET AND IS REQUIRED TO BE DONE AT SITE TO COMPLETE THE WORKS
FOR APPROVAL PRIOR TO IMPLEMENTATION ON SITE.
11. CONTRACTOR TO VERIFY AND MARK ON SITE THE SETTING-OUT FOR ALL TOILET
D10 1 FIXTURES. TO VERIFY MANUFACTURER'S INSTALLATION REQUIREMENTS AND
2000
1800
2 PREPARATIONS NEEDED FOR PROPER INSTALLATION OF ALL FIXTURES.
12. REFER TO ACOUSTIC CONSULTANT'S DRAWING PACKAGE FOR SOUND INSULATION
EOWD10 L7-48110 L7-48111 RATING AND SPECIFICATION.
13. REFER TO DOOR SCHEDULE FOR ALL INTERIOR DOOR INFORMATION.
14. VERIFY AT JOBSITE ALL DIMENSIONS PRIOR TO CONSTRUCTION.
15. CONTRACTOR TO VERIFY TERMINATIONS ON SITE WITH THE DESIGNER.
245 1200 1200 145 1000 525 1200 1200 1200 1200 1200 425 2000 675 1170 1210 2680 1255 735 1200 1200 735 16. REPORT TO INTERIOR DESIGNER ANY INCONSISTENCIES AND CONFLICTS FOUND
AT JOBSITE PRIOR TO ADJUSTMENT ON DESIGN AND DETAILS IN DRAWINGS (IF
D10
150
ANY).
50
FLOOR FINISH NOTES:
1. ALL WALL FINISHES ARE INDICATED ON ELEVATION DRAWINGS.
2. THIS PLAN INDICATES THE TYPES OF FINISHES. FLOOR FINISHES TO CONTINUE TO
TOE KICK OR BASE OF MILLWORK. REFER TO DETAILS INDICATED FOR ADDITIONAL
D9A SD04 INFORMATION.
3. ALL FINISH MATERIALS PROVIDED MUST COMPLY WITH THE REQUIREMENTS OF
APPLICABLE CODES, RULES, REGULATIONS, LAWS, ORDINANCES, ETC. AS
REQUIRED BY THE PUBLIC AUTHORITIES.
EOSD9 4. ALL STONE AND TILE FINISHES INSTALLED AT FLOOR SURFACES ARE TO MEET OR
G F E
2. POWER/ DATA RECEPTACLES ABOVE COUNTERS TO BE MOUNTED AT 150mm ABOVE
FINISHED COUNTERTOP TO CENTERLINE OF COVER PLATE, TYPICAL UNLESS OTHERWISE
NOTED.
REFER TO SETTING OUT PLAN 1 OF 3
5' EOWD1
SPRINKLER EQUIPMENT (INCLUSIVE OF ALL PIPING, DUCTWORK AND CONDUIT) AND THAT
ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ABOVE EQUIPMENT
IS PROVIDED.
8. PAINTED SWITCH AND/ OR OUTLET COVER PLATES,SPEAKERS, FIRE EXTINGUISHER
CABINETS, ELECTRICAL PANELS AND ACCESS PANELS TOO BE SHOPFINISHED. FACTORY
PAINT FINISH TO MATCH COLOR SELECTED BY DESIGNER.
9. ALL ELECTRICAL SWITCH & OUTLET RECEPTACLES PLEASE REFER TO FF&E LIST OF
SPECIFICATIONS.
860 1190 1190 1190 1190 1190 1190 1190 860 1055 1055 1055 860 955 955 955 955 1085 625 650 1160 1045 FF&E NOTES:
1. FOR ALL ROUGH CARPENTRY AND BLOCKING, INSTALL FIRE- RETARDANT TREATED WOOD
20950 2000 AS REQUIRED TO COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES, RULES,
REGULATIONS, LAWS, ORDINANCES, ETC. AS REQUIRES BY THE PUBLIC AUTHORITIES.
2. COORDINATE INSTALLATION OF IN-WALL STEEL ANCHORAGES, GROUNDS AND
1 2 LIFT DIRECTORY SIGN BY 4 4 MISCELLANEOUS BLOCKING WITH OTHER CONTRACTORS TO DETERMINE PRECISE
LOCATIONS.
L7-48110 L7-48111 SIGNAGE CONSULTANT 3. MILLWORK CONTRACTOR SHALL OBTAIN AND VERIFY ALL FIELD MEASUREMENTS AND
CONDITIONS AFFECTING HIS/ HER WORK AND SHALL BE RESPONSIBLE FOR ALL DETAILS
AND DIMENSIONS ASSURING PRECISION FITTING AND PROPER ASSEMBLY OF HIS/ HER
58290 PRODUCTS.
4. WORK SHALL BE ACCURATELY SET PLUMB, LEVEL AND SECURE FASTENED TIGHTLY AND
1200 1200 735 1150 1200 410 1000 290 1250 975 1005 600 2700 600 1165 1115 1065 1000 650 1160 775 1200 775 1160 570 ACCURATELY TO ADJACENT SURFACES, AND SECURELY ANCHORED IN POSITION INDICATED
ON DRAWINGS AND APPROVED SHOP DRAWINGS.
D9 NOTE: 5. REPAIR, REPLACE OR OTHERWISE MAKE GOOD ALL DAMAGE INCURRED TO PRE-FINISHED
100
100
WOODWORK DURING HANDLING AND INSTALLATION.
- FOR ALL ELECTRICAL SWITCHING, REFER TO 6. ADJUST DOORS, DRAWERS AND ALL HARDWARE FOR PROPER OPERATION AND CLEAN ALL
CABINET SURFACES, INSIDE AND OUTSIDE.
ELECTRICAL AND LIGHTING CONSULTANT 7. SHOP DRAWINGS OF ALL MILLWORK ITEMS TO BE SUBMITTED TO DESIGNER FOR WRITTEN
EOWD7 SD03B - MEPF REFERENCE DATED MAY 2021
APPROVAL PRIOR TO FABRICATION.
8. STAINED CABINET AND DOOR FINISHES ARE TO BE SHOP- FINISHED UNLESS OTHERWISE
NOTED.
- MEPF & ELV LOCATIONS FOR COORDINATION WITH 9. ALL LOOSE FURNITURE REFLECTED HEREIN ARE REPRESENTATION ONLY AND ARE NOT
MEPF & ELV CONSULTANTS PART OF THE BASE BUILDING CONTRACT. THIS WILL BE PART OF THE INTERIOR FIT-OUT
FEMALE RESTROOM SIGN - FOR FINAL SIGNAGE LOCATION, REFER TO OF APPLICABLE CODES, RULES, REGULATIONS, LAWS, ORDINANCES,ETC. AS REQUIRED BY
THE PUBLIC AUTHORITIES. IN THE EVENT OF A CONFLICT THE MOST STRINGENT
SIGNAGE CONSULTANT. REQUIREMENTS SHALL APPLY.
BY SIGNAGE CONSULTANT - FIRE-RETARDANT-TREATED PANELING: PANELS 3. PAINTED SPRINKLER COVER PLATES, SPEAKERS, LIGHT FIXTURE TRIM RINGS, FIRE
L7 EXECUTIVE OFFICES CORRIDOR EXTINGUISHER CABINETS, ELECTRICAL PANELS AND ACCESS PANELS TO BE SHOP-
FINISHED, FACTORY PAINT FINISH TO MATCH COLOR SELECTED BY THE DESIGNER.
SHALL CONSIST OF WOOD VENEER AND
2 SETTING OUT PLAN PART 2 OF 3 4 FIRE-RETARDANT; MEDIUM-DENSITY FIREBOARD
4. PAINT ALL DUCTWORK BLACK BEHIND DIFFUSER GRILLES, TYPICAL UNLESS OTHERWISE
NOTED.
5. ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATION
L7-48100 SCALE 1:50 (A1) / 1:100 (A3) (MDF). PANELS SHALL HAVE A FLAME-SPREAD INDEX FOR THAT PARTICULAR SURFACE. TWO- COAT MINIMUM APPLICATION REQUIRED, UNLESS
OTHERWISE NOTED.
SOLAIRE EXEC. OFFICE OF 25 OR LESS AND A SMOKE-DEVELOPED INDEX OF 6. COORDINATE ALL A/V EQUIPMENT LOCATIONS AND REQUIREMENTS WITH A/V CONSULTANT.
7. ELECTRICAL/ MECHANICAL DRAWING PROVIDED ARE FOR THE PLACEMENT AND/ OR
4 450 OR LESS AS PER ASTM E84, AND BE LISTED AND
REFER TO SETTING OUT PLAN 2 OF 4
SIGN BY SIGNAGE GENERAL ARRANGEMENT OF FIXTURES, OUTLETS, ETC. AS RELATED TO THE DESIGN
LABELED BY A TESTING AND INSPECTING AGENCY INTENT. ALL REQUIRED ENGINEERING AND/ OR CALCULATIONS TO BE PERFORMED BY
E 1 D CONSULTANT
C ACCEPTABLE TO AUTHORITIES HAVING
JURISDICTION.
OTHERS, UNLESS OTHERWISE NOTED.
8. REFER TO REFLECTED CEILING PLAN FOR INSTALLATION LOCATIONS OF ALL CEILING
MOUNTED DECORATIVE LIGHT FIXTURES.
9. REFER TO ELECTRICAL, HVAC AND FIRE PROTECTION DRAWINGS FOR SWITCHING, EXIT
00-25066 SIGNS, EMERGENCY LIGHTING, DUCT, GRILLE, DIFFUSER LOCATIONS AND COORDINATION
4 OF SPRINKLER HEAD LOCATIONS. ANY CONFLICT WITH LIGHTING FIXTURE LOCATIONS
L7-48111
L7 KEY PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND COORDINATE.
10. INTERIOR DESIGN (ID) CEILING PLANS ARE INTENDED TO SHOW CEILING FINISHES AND
PROFILES ONLY.
11. SEE INTERIOR DESIGN (ID) FLOOR PLANS FOR LOCATION OF ADDITIONAL DECORATIVE
D1
5'
LIGHTING NOT SHOWN ON CEILING PLANS (I.E. STAIR LIGHTS, AISLE LIGHTS). ALSO
4 5 5' 6 INDICATED ON FLOOR PLAN ARE SPECIAL OUTLET LOCATIONS REQUIRED FOR PLUG-IN
FLOOR AND TABLE LAMPS. (COORDINATE WITH ELECTRICAL DRAWINGS, ID FURNISHINGS
EOWD1 PLANS AND DECORATIVE LIGHT FIXTURES AND CATALOGUE CUTS).
12. THE PURPOSE OF THIS DRAWING IS FOR CONTRACTOR'S REFERENCE FOR DECORATIVE
L LIGHT FIXTURE AND ACCESSORIES (CHANDELIER) POSITIONS/ LOCATIONS FOR NECESSARY
SUPPORT SYSTEM PROVISIONS.
200
13. SEE INTERIOR ELEVATIONS FOR LOCATION AND MOUNTING HEIGHTS OF WALL MOUNTED
1085 625 650 1160 1045 1045 1045 1045 1160 1045 1045 1045 1045 1160 1380 FIXTURES. SEE DETAILS FOR SPECIAL LIGHT FIXTURE MOUNTING CONDITIONS.
2000 14000
K 14. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL CASEWORKS FOR MOCKING-UP.
15. PROVIDE ADEQUATE BLOCKING CEILING AND/ OR WALL TO SUPPORT CEILING MOUNTED
DECORATIVE LIGHT FIXTURES AND ARTWORKS.
200 900 200 16. CEILING SERVICE ACCESS TO PLS. REFER TO MEPF LAYOUT (SUBJECT FOR DESIGNER'S
2 D4 J APPROVAL).
1 17. REFER TO LIGHTING CONSULTANT DRAWINGS FOR ALL LIGHTING REQUIREMENTS,
1700
SPECIFICATIONS AND DETAILS.
L7-48110 L7-48111 18. REFER TO LIGHTING CONSULTANT'S DRAWINGS FOR FIXTURE TYPE AND LOCATION OF ALL
EOWD4 H ARCHITECTURAL FUNCTIONAL LIGHTING.
19. REFER TO M&E CONSULTANT'S DRAWINGS FOR AIR CONDITIONING SYSTEM.
20. REFER TO ACOUSTIC CONSULTANT FOR CEILING INSULATION AND STC/ NRC RATING FOR
ADEQUATE DETAIL.
650 1160 775 1200 775 1160 570 2000 650 1160 980 980 990 1160 550 1000 980 905 1300 G 21. ALL CEILING HEIGHTS TO BE VERIFY ON SITE.
22. VERIFY AT JOBSITE ALL DIMENSIONS PRIOR TO CONSTRUCTION.
D10 D9
200
23. CONTRACTOR TO VERIFY TERMINATIONS ON SITE WITH THE DESIGNER.
24. CONTRACTOR TO PROVIDE MARKING OF LIGHT POINTS POSITION FOR DESIGNER'S
F APPROVAL BEFORE INSTALLATION.
25. REPORT TO INTERIOR DESIGNER ANY INCONSISTENCIES AND CONFLICTS FOUND AT
JOBSITE PRIOR TO ADJUSTMENT ON DESIGN AND DETAILS IN DRAWINGS (IF ANY).
SD04B EOSD9A E FOR CONSTRUCTION DRAWING
This Drawing is the property of CASAS+ARCHITECTS and is not to be reproduced or copied in whole
or in part. It is only to be used for the project and site specifically identified herein and is not to be used
D on other projects. It is to be returned upon request.
B 2 SOLN-CR-SUR-NP-0010
AUGUST 10, 2021
2 SOLN-CR-SUR-NP-0009
2 SOLN-CR-SUR-NP-0011 AUGUST 10, 2021
N
L7 EXECUTIVE OFFICES CORRIDOR 2 SOLN-CR-SUR-NP-0006 AUGUST 10, 2021
1 CLARIFICATION APRIL 30, 2021
3 SETTING OUT PLAN PART 3 OF 3 0
REV NO
CONSTRUCTION DRAWING
DESCRIPTION
MARCH 2021
DATE
L7-48100 SCALE 1:50 (A1) / 1:100 (A3)
ISSUE STATUS:
0 1 2 5 10