PROJECT: KABAYAN 3 HYDRO POWER PLANT

LOCATION: KABAYAN, BENGUET


DESIGN OF BIFURCATION
DATA:
PENSTOCK LENGTH = 120.00 m
DESIGN DISCHARGE = 6.35 m3/sec
GROSS HEAD= 97 m
NET HEAD = 85 m
CAPACITY= 4667 KW

PROJECT:
Q(DISCHARGE)= 6.35 m 3/sec
USING MANNING'S FORMULA TO COMPUTE FOR THE VELOCITY
A(AREA)= 1.704 m2
P(PERIMETER)= 4.627 m
R(HYDRAULIC RADIUS)= 0.368 m
V(VELOCITY)= 3.729 m/sec
D (DIAMETER OF PIPE)= 1.473 m INITIAL DIAMETER
VELOCITY 3.729 m/sec
PIPE DIAMETER
EFFECTIVE LENGTH= 46 1.473
meters m
OPTION 1-USING THE FORMULA FOR OPTIMUM DIAMETER (HYDRAULIC BOOK)
FORMULA 1 DIAMETER = 0.71P^0.43/H n^0.65
D= 1.50 m
DISCHARGE 6.35 m3/sec
PIPE DIAMETER (OPTIMUM) 1.50 m
OPTION 2-USING THE FORMULA FOR OPTIMUM DIAMETER (HYDRAULIC BOOK)
FORMULA 2 DIAMETER = 0.49P^0.43/H n^0.57
D= 1.47 m
3
DISCHARGE 6.35 m /sec
PIPE DIAMETER 1.47 m

DATA:
PENSTOCK LENGTH = 120 m
DESIGN DISCHARGE = 6.35 m3/sec
GROSS HEAD= 97 m
LENGTH OF PENSTOCK = 120.00 m
DESIGN DISCHARGE = 6.35 cu.m./sec
GROSS HEAD = 97.00 m
COMPUTED OPTIMUM PENSTOCK DIA. = 1.55 m
COMPUTED PIPE PRESSURE (STATIC) = 951.57 kPa
COMPUTED WATER HAMMER ALLOWANCE = 285.47 kPa
TOTAL PRESSURE IN PIPE = 1,237.04 kPa
COEFFICIENT OF "Y" = 0.40
THREADING "C" = 1.65

BIFURCATION SPECIFICATIONS

ASTM A36 Grade B = 413,700.00 kPa


THICKNESS OF PIPE (COMPUTED) = 4.95 mm
MINIMUM THICKNESS = 6.86 mm
STANDARD MINIMUM THICKNESS = 10.00 mm
USE (ACTUAL THICKNESS) = 9.80 mm(nominal thickness)
DIAMETER OF BIFURCATION = 1.55 m

ANCHOR BLOCK DESIGN