ME Supplies

Defibrillator
Accessories and Consumables
Defibrillator Pastes, Disposable Pads, Batteries

Disposable pads
P-740K H329 (P-711) H330 (P-713) H331 (P-721) H327A (P-511X)

Order Code Model Length Applicable for


P-740K - 1.5 m Adult, child, infant
H329 P-711 1.5 m Adult, child, infant*
H330 P-713 1.5 m Infant (under 1 year old)
H331 P-721 2.5 m Adult, child, infant*
H327A P-511X 1.5 m Adult, child
*For infants less than 1 year old, use of the p-713 disposable pads takes priority over user of the P-711 or P-721 disposable pads.

Contact gel Pad adapter


For TEC-5600/8300
Order Code Model Length
K342B JC-865V 2 m
For EMS-1052
Order Code/Model Length
Order Code Model Volume Quantity
JC-165V 1m
F015A Z-101BA 100 g 2 tubes

Recording paper Test load unit


For TEC-5600/8300 Order Code Model
Order Code Model Quantity Width × Length Type Y206A AX-250V
A128 RQS50-3 10 50 mm × 30 m Roll
For EMS-1052
Order Code/Model Quantity Width × Length Type
PAPER-00001 10 110 mm × 20 m Roll

Battery

For TEC-5600 For TEC-8300


Order Code Model Order Code Model
X065 NKB-301V X077 SB-831V

For EMS-1052
Order Code/Model
SB-121V-CL
Cables, Electrodes Leads Defibrillator
ECG connection cords ECG patient cables
For TEC-5600/8300/EMS-1052 For TEC-8300/EMS-1052

For 3/6 electrodes For 10 electrodes


Order Code Model Length Type Order Code Model Length Type
K922 JC-906P 3m IEC K901 BJ-900P 3.8 m IEC
K922A JC-906PA 3m AHA K901A BJ-900PA 3.8 m AHA
K925 JC-916P 1.5 m IEC

ECG patient cables


For TEC-8300/EMS-1052 For 10 electrodes
Limb + chest lead
Order Code (Model) Type
K354 (BJ-831V) + K913A (BR-906A) IEC
K354A (BJ-831VA) + K913B (BR-906VA) AHA

Electrode leads

For 3 electrodes For 6 electrodes


Order Code Model Length Type Lead type Order Code Model Length Type Lead type
K911 BR-903P 0.8 m IEC Clip K912 BR-906P 0.8 m IEC Clip
K911A BR-903PA 0.8 m AHA Clip K912A BR-906PA 0.8 m AHA Clip
K910A BR-913P 0.8 m IEC Snap K915 BR-916P 0.8 m IEC Snap
K910B BR-913PA 0.8 m AHA Snap K915A BR-916PA 0.8 m AHA Snap
K917 BR-923P 1.5 m IEC Clip K918 BR-926P 1.5 m IEC Clip
Defibrillator Disposable Electrodes

The result of over 30 years experience


in disposable electrode manufacturing

Vitrode L
• 35 mm diameter for adult use.
• For general ECG and 12-lead ECG monitoring.
• Less gel remains when removed from the skin.
• Low impedance for clear waveform.
• Radiolucent.
• Non-clinical studies have shown that this electrode fits MR conditionally.
The MR test can be safely performed on a patient wearing this electrode
L-150X(G207) under the following conditions, based on self-certification.
1. Static magnetic field strength 1.5T and 3.0T
No protrusion of gel 2. Switched gradient magnetic field 45T/m
3. Maximum whole body SAR displayed by the MR equipment
2W/Kg in normal operation mode
∙ The maximum temperature rise occurring in this electrode under the
above conditions is less than 0.1°C (32.18℉) for every 15minutes of
continuous MR scanning
∙ The maximum size of artifact appearing in images acquired with 3T
MR equipment using gradient echo is 6.9 mm
Radiolucent
Order Code Model Quantity Size Applicable for
G207 L-150X 30 pcs/pack × 5 packs 35 mm dia Adult
Adhesion Skin Friendliness
★★★★ ★★
*Number of stars is for reference only, dependent on patients’ skin condition.

Vitrode F

• Smaller size for neonate to child


• Entire attachment area has a conductive and adhesive gel to reduce
skin irritation
• Contain denatonium, unharmful bitter agent, to help prevent accidental
ingestion by children
• Radiolucent
• Small sized packaging to prevent drying during storage
• Can be reapplied if it is immediately after the first application
F-150M (G210D) F-150S (G210C)

Order Code Model Quantity Size Applicable for


G210D F-150M 3 pcs/sheet × 50 packs 25 × 45 mm Adult, child
G210C F-150S 3 pcs/sheet × 50 packs 19 × 36 mm Neonate, child

Order Code Model Adhesion Skin Friendliness


G210D F-150M ★★★ ★★★★★
G210C F-150S ★★ ★★★★★
*Number of stars is for reference only, dependent on patients’ skin condition.
Disposable Electrodes Defibrillator
Vitrode V

V-090M3 (G272A) V-040M4 (G272B) V-060M6 (G272C)

• Lead wires are attached together to prevent tangling in incubators


• Radiolucent
• Conductive adhesive gel is used to reduce skin irritation
• Good visibility due to the same color of connectors and cables

Radiolucent, prewired
Order Code Model Quantity Size Length Applicable for
G272A V-090M3 3 colors/sheet × 30 packs 25 × 45 mm 1.0 m Adult, child
G272B V-040M4 4 colors/sheet × 10 packs 25 × 45 mm 1.0 m Adult, child
G272C V-060M6 6 colors/sheet × 10 packs 25 × 45 mm 1.0 m Adult, child
G278A V-09IO3 3 colors/sheet × 30 packs 25 × 45 mm 1.5 m Adult, child
G273A V-04IO4 4 colors/sheet × 10 packs 25 × 45 mm 1.5 m Adult, child
G274A V-06IO6 6 colors/sheet × 10 packs 25 × 45 mm 1.5 m Adult, child
Defibrillator Disposable Electrodes

Vitrode M
• Strong adhesive tape material (Foam tape)
• Made to be difficult to peel off even if water and medical solution
gets on the electrode
• Low-noise monitoring is possible immediately after the application
• Radiolucent

Whole surface adhesion


Order Code Model Quantity Size Applicable for
G236 M-150 30 pcs/pack × 5 packs 40 mm dia Adult

Adhesion Skin Friendliness


★★★★★ ★★
*Number of stars is for reference only, dependent on patients' skin condition.

Disposable Electrode

• Adhesive gel
• Makes it easy to use when measuring 12-lead ECG
• Radiolucent
• Zippered bag to prevent electrodes from drying
• Skin friendly

Whole surface adhesion


Order Code Model Quantity Size Applicable for
G270A NC-032Y 100 pcs/pack × 5 packs 20 × 22.5 mm (excluding tab) Adult

Adhesion Skin Friendliness


★★★ ★★★★★
*Number of stars is for reference only, dependent on patients' skin condition.

Pinch the tab with a clip type electrode lead.


Disposable Electrodes Defibrillator
Guide for which Vitrode to offer to which site
Site Best matching Vitrode Reasons

• Made to be difficult to peel even if


water and medical solution gets on the
electrode.
Operating Room,
E.g., Preoperative antiseptic solution
Emergency Room
• Low-noise monitoring is possible
immediately after the application.
E.g., Emergency Room

F-150M
• Adhesion is weaker than M-150
however, reduces skin irritation for
Intensive Care Unit, patients with sensitive skin.
Coronary Care Unit etc.
"X"CU M-150
• Strong adhesion and resistance against
water, medical solution, and other
liquids.

• Skin friendly.
• Contains denatonium to help prevent
General Ward accidental ingestion.
• Small sized packaging to prevent
drying.

• Skin friendly.
Pediatric Ward • Contain denatonium to help prevent
accidental ingestion by children.
Defibrillator Disposable Electrodes

Vitrode N
Designed for High-Humidity Incubators
• Durable and adhesive gel hardly swells, preventing electrodes from
peeling even under humid environment
• Smallest electrodes among Vitrode series
• Soft radiolucent lead wires are bundled to prevent the leads being
tangled around the baby

G300D (N-01IS3) Adhesion


Skin Adhesive Strength
Humidified Non-Humidified Friendliness to Body Movement
Environment* Environment
★★★★★ ★★★ ★★★★ ★★
*Humidified environment means inside incubator; indicates durability of electrodes in incubator.
Star indicates the strength in each category. The more stars the better the electrodes address
the category

Skin-Friendly with Gentle Adhesive


• Skin-friendly adhesive gel; gentle for less skin irritation
• Electrodes for the baby whose dermis is immature
• Soft radiolucent lead wires are bundled to prevent the leads being
tangled around the baby

Adhesion
Skin Adhesive Strength
G300A (N-03IS3)
Humidified Non-Humidified Friendliness to Body Movement
Environment* Environment
★ ★★ ★★★★★ ★
*Humidified environment means inside incubator; indicates durability of electrodes in incubator.
Star indicates the strength in each category. The more stars the better the electrodes address
the category

Vitrode V
Available from Neonate to Infant
• Bitter chemical compound is used on the electrodes to prevent
accidental swallowing
• Electrodes are specifically designed for the more active baby
• Soft radiolucent lead wires are bundled to prevent the leads being
tangled around the baby

Adhesion
Skin Adhesive Strength
Humidified Non-Humidified Friendliness to Body Movement
G271A (V-120S3) Environment* Environment
★★ ★★★★ ★★ ★★★★
*Humidified environment means inside incubator; indicates durability of electrodes in incubator.
Star indicates the strength in each category. The more stars the better the electrodes address
the category

Order Code Model Quantity Size Length Applicable for


G271A V-120S3 3 colors/pack ×40 packs 20 × 20 mm 0.6 m Infant to neonate*
G300A N-03IS3 3 colors/pack ×10 packs 14 × 25 mm 0.6 m Low birth weight to infant*
Very low birth weight
G300D N-01IS3 3 colors/pack ×10 packs 15 mm dia 0.6 m
Extremely low birth weight
*prewired
SpO2 Defibrillator
Reliable SpO2 probes
from the company that invented SpO2

SpO2 probe selection guide


Weight Low-birth-weight-infants Neonate Child Adult
1,000g 3kg 4kg 10kg 20kg 30kg 40kg 50kg
TL-271T
Single-patient use

TL-272T

TL-273T

TL-274T

TL-260T Type S Type L Type S

TL-535U Type S Type L Type XL

TL-201T
Reusable

TL-220T

TL-630T3

TL-631T3
For Earlobe

TL-260T+P256,
Ear clip

* Applicable weight is for reference only

Nihon Kohden recommends combination use of single-patient use


probes and reusable probes depending on patients’condition.
Reusable SpO2 probes

Multi-site, from neonate to adult, Finger-tip type, 20 kg or more


Order Code Model Length finger or instep Order Code Model Length
P225F TL-201T2 1.6 m Order Code Model Length P311C TL-631T3 1.6 m
P225H TL-201T1 0.6 m P225G TL-220T 1.6 m
Finger-tip type, 50 kg or more
Order Code Model Length
P310C TL-630T3 1.6 m
Defibrillator SpO2

Single-patient use SpO2 probes


Adult finger/toe
Adhesive
Child finger/toe Order Code Model Quantity Length Applicable for
P203A TL-271T 24 0.8 m
Adult finger/toe
P203E TL-271T3 24 1.6 m
P203B TL-272T 24 0.8 m
Child finger/toe
P203F TL-272T3 24 1.6 m
P203C TL-273T 24 0.8 m
Neonate instep
P203G TL-273T3 24 1.6 m
Neonate instep
P203D TL-274T 24 0.8 m
Infant finger/toe
P203H TL-274T3 24 1.6 m

Infant finger/toe

Non-adhesive, for sensitive skin


P205A (TL-260T)
Order Code Model Quantity Applicable for
1 sensor + 4 sponge tape L/ Neonate
P205A TL-260T
set×5 packs Adult (with ear clip)

S size: P260E L size: P260F

Attachment tape for TL-260T Ear clip, adult use with TL-260T
Order Code/Model Quantity Size Order Code/Model
S: 1 kg or less at instep P256
P260E 24
3 kg to 10 kg at finger/toe
P260F 24 L: 1 kg or more

Non-adhesive, for sensitive skin


S size: P264A
Order Code Model Quantity Attachment site
L size: P264B P206 TL-535U 5 sets Neonate and preterm infant

Attachment tape for TL-535U


Order Code/Model Quantity Size
P206 (TL-535U)
P264A 6 tapes/pack × 4 packs S: 1kg or less
P264B 6 tapes/pack × 4 packs L: 2.5 kg or less
SpO2 Defibrillator
Fixing tapes
Order Code/Model Quantity
COTTONY tape P259 20
BluPRO attachment tape P263A 3 tapes/sheet ×30 packs
P259 P263A Probe fastener P267 30
Foam tape P260D 4 tapes/sheet ×25 packs

P267 P260D

Connection Cords for P206 (TL-535U)


Order Code Model Length
For OLV K939B JL-430U 2.9 m
With BSM/CSM/PVM K930 JL-930P 3m
K939B K930 With K931 (JL-900P) K929A JL-030U1 0.3 m
or L311 (JL-302T) K929B JL-030U2 1m

K929A K929B

Connection Cords
For BSM/CSM/PVM
Order Code Model
K931 JL-900P

To have a stable SpO2 measurement


6~18mm

 Select an attachment site with an appropriate thickness


In most cases, the probe should be attached across a
measurement site with a thickness of 6-18 mm.
 For accurate measurement
It is important that the light emitter and photo detector
6~18mm
face each other.
Light emitter Light emitter

Good Bad
Example Example

Photo detector Photo detector


Defibrillator CO2

Nihon Kohden’s unique sensing technology for


both intubated and non-intubated mainstream CO2 measurement

CO2 sensor, Quantitative method


• Weighs only 4 g*
• IPX 7 protection against immersion in water
• Accurate for intubated and non-intubated patients
• Reliable even under high humidity conditions
• Durable enough for use in harsh environments
• Safe heater-less system prevents burn injuries
*The sensor weighs 4 grams (does not include the cable and the connector)

Order Code Model Length


P910A TG-980P 2.9 m

The Optimal Capnography Solution


For Respiratory Management

Airway adapter for intubated patients


R805 (YG-211T) Order Dead Applicable
Code Model space Weight Connection Quantity for
R806 (YG-213T) 7 kg or Adult,
R805 YG-211T 4 mL - 30
more child
Connect flow sensor or
Infant,
R806 YG-213T 0.5 mL -
respiration circuit without 30
neonate
inner connector
Connect flow sensor with Infant,
R807 (YG-214T) R807 YG-214T 1.8 mL 2.5 to 7 kg 30
an inner connector neonate

cap-ONE mask for non-intubated patients

V938A (YG-272T) V938C (YG-282T) V933 (YG-232T) V935 (YG-242T)

Order Dead Applicable


Code Model space Weight Quantity for
V938A YG-272T 7 mL 30 kg or more 10 Adult
V938C YG-282T 10 mL 40 kg or more 10 Large adult
V933 YG-232T 3.5 mL 20 to 40 kg 10 Child
V935 YG-242T 2.5 mL 7 to 20 kg 10 Infant
Ensure Quality of care under Sedation
Accurate respiratory monitoring with optimal oxygen supply
CO2 Defibrillator
Biteblock during endoscopy
Order Quantity Applicable
Model
Code for
V939A YG-227T 20 Adult

Nasal adapter

Order Code/Model Quantity Applicable


YG-221T YG-231T
for
YG-220T 30 Adult
YG-221T 30 Adult
YG-230T 30 Child
YG-220T YG-230T
YG-231T 30 Child

No need to connect the nasal adapter and the oxygen tube. (Compared to YG-120T series for TG-920P)

P907 (TG-920P) V922 (YG-121T) V927A P910A (TG-980P) YG-231T

P903 P907 P910A


(TG-900P) (TG-920P) (TG-980P)

Multigas - - -
Flow/Paw - - -
Sidestream CO2 - - -

Semi-
✓ ✓ -
Main quantitative
stream CO2
Quantitative - - ✓

Intubated ✓ ✓ ✓
Non-intubated - ✓ ✓
Neonate - - ✓
✓Available Not available
Defibrillator CO2

CO2 mainstream, intubated and non-intubated (Semi-quantitative method)


CO2 sensor kit CO2 adapter
Order Code Model
P907* TG-920P
*TG-121 + JG-920P

Order Code Model


K984 JG-920P

Nasal adapters (non-intubated) Airway adapter (intubated)


V923
(YG-122T)

V922
(YG-121T)

Order Code Model Dead space Weight Quantity Order Code Model Dead space Weight Quantity
V922 YG-121T 1.2 mL 10 kg or more 30 R804 YG-111T 4 mL 7 kg or more 30
V923* YG-122T 1.2 mL 10 kg or more 30
* With O2 supply tube adapter

CO2 mainstream, intubated (Semi-quantitative method)


CO2 sensor kit CO2 adapter Airway adapter

Order Code Model Order Dead


Code Model space Weight Quantity
K981 JG-900P
R801 YG-101T 5 mL 10 kg or more 50

Order Code Model


P903* TG-900P
*TG-101T + JG-900P

● Reaction time from respiratory arrest to


cardiac arrest for each parameter
Disappearance of
Respiratory
Adult CO 2 Waveform
Arrest 5 min remain
Child
2 min remain
CO2 measurement detects respiration failure earlier than SpO2
and ECG. CO2 monitoring leads to earlier intervention for
30 - 60 sec remain Decrease in improved patient safety.
Cardiac 10 sec remain SpO2 value
arrest
Changes in ECG
NIBP Defibrillator
Disposable NIBP cuffs
Order Applicable
Code Model Width Range Quantity for
S954A YP-840T 5 cm 8-13 cm 20 Infant
S954A S954B YP-841T 7 cm 13-18 cm 20 Child
(YP-840T)
S954B
(YP-841T) S954C YP-842T 10 cm 18-23 cm 20 Adult, small
S985C
(YP-842T)
S954D YP-843T 13 cm 23-33 cm 20 Adult
S954D
(YP-843T) S954E YP-844T 16 cm 33-45 cm 20 Adult, large
S954E
(YP-844T)
S954F YP-845T 19 cm 45-55 cm 20 Thigh
S954F
(YP-845T)

Order Applicable
Code Model Width Range Quantity for
S948F YP-820S 2 cm 3-6 cm 10 Neonate
S948G YP-821S 3 cm 4-8 cm 10 Neonate
S948H YP-822S 4 cm 6-11 cm 10 Neonate
S948I YP-823S 4.5 cm 7-13 cm 10 Neonate
S948J YP-824S 5 cm 8-15 cm 10 Neonate
S948F S948G S948H S948I S948J
(YP-820S) (YP-821S) (YP-822S) (YP-823S) (YP-824S)

IEC 3rd edition


Snap Connector

IEC 3rd edition air hose

IEC 3rd edition snap connector An IEC 3rd edition neonate air hose
cannot be connected to cuffs with the
An IEC 3rd edition neonate air hose can only be connected previous IEC edition snap connector.
to disposable cuffs with an IEC 3rd edition snap connector.
Defibrillator NIBP

Reusable NIBP cuffs YAWARA CUFF2


S951A S951B S951C S951D S951E S951F
(YP-710T) (YP-711T) (YP-712T) (YP-713T) (YP-714T) (YP-715T)

Order Code Model Width Range Applicable for


S951A YP-710T 5 cm 8-13 cm Infant
S951B YP-711T 7 cm 13-18 cm Child
S951C YP-712T 10 cm 18-23 cm Adult, small
S951D YP-713T 13 cm 23-33 cm Adult
S951E YP-714T 16 cm 33-45 cm Adult, large
S951F YP-715T 19 cm 45-55 cm Thigh

Airhose

S903 (YN-990P) S902 (YN-901P) S905A (YN-925P)

Extension cord for S901 (YN-900P)


Order Code Model Length Order Code Model Length Applicable for
S903 YN-990P 1.5 m S902 YN-901P 3.5 m Adult, child
S901 YN-900P 1.5 m Adult, child
S905A YN-925P 3.5 m Neonate
S904A YN-924P 1.5 m Neonate

iNIBP method and Step deflation method


iNIBP
Step deflation method
Target inflation
pressure (180)
Lower
pressure
Step
Cuff pressure (mm Hg)

deflation
SYS
method

DIA

Shorter
measurement time

Time (sec)
Temperature, IBP Defibrillator
Temperature
Temperature probe Probe covers Insulation pads
TT-481T
YT-411T YT-410T

TT-480T

Order Code Type Applicable for Order Code Type Quantity Order Code Type Quantity
TT-481T Disk Adult YT-411T For TT-411T 20 For TT-481T,
YT-480T 60
TT-480T Disk Neonate, child YT-410T For TT-410T 20 TT-480T

TT-411T Temp connection cord

TT-410T

Order Code Type Applicable for


TT-411T Catheter Adult
Order Code Model
TT-410T Catheter Neonate, child
K961 JT-900P
• For Temp connector expansion
IBP
IBP connection cords

Order Code Model Order Code Model Length Order Code Model Order Code Model
K951 JP-900P L901 JP-920P 3.5 m K957 JP-960P K952 JP-910P
• Use with MERIT L902 JP-921P 1.5 m • Use with Biosensors • For 5P connector
MEDICAL transducer • Use with Edwards transducer
Lifescience transducer
Defibrillator Batteries, Disposable Pads, PBLADE

AED battery Disposable pads


For AED-2100/2150 series (Non-rechargeable) For AED-2100/2150/3100 series

Order Code/Model Stand-by life Order Code/Model Applicable for


SB-212VK 2 years
P-740K Adult, child
SB-214VK 4 years

For AED-2150 series (Rechargeable)


Order Code Model
X233 SB-220V

For AED-3100 series (Non-rechargeable)


Order Code/Model Stand-by life
SB-310V 4 years

PBLADE
For AWS-S200K
ITL-SL ITL-TL ITL-PL ITL-NL

Order Code Model Quantity Applicable for


ITL-SL-EU ITL-SL 10 Adult
ITL-TL-EU ITL-TL 10 Small adult
ITL-PL-EU ITL-PL 10 Pediatric
ITL-NL-EU ITL-NL 10 Neonate

CPR Assist acessories


Order Code Model Quantity Note
Y204A YZ-056H8 5 Chest sheet
Y204B YZ-056H9 1 Hand cushion

Y204B

Y204A
Some products may not be available in your country.
Contact your Nihon Kohden representative for details.
This brochure may be revised or replaced by Nihon Kohden at any time without notice.