Data Sheet

ADBMS6816
Multicell Battery Monitor

FEATURES TYPICAL APPLICATION CIRCUIT


► Measures up to 6 battery cells in series
► Maximum lifetime total measurement error: 1.5 mV
► Stackable architecture supports hundreds of cells
► Built-in isoSPI interface
► 2 Mbps isolated serial communications
► Uses a single twisted pair, up to 20 meters
► Low EMI susceptibility and emissions
► Bidirectional for broken wire protection
► Capacitor or transformer coupled
► Hot plug tolerant without external protection
► Designed for high reliability systems
► Includes redundant cell measurements
► Diagnostic coverage of operational modes
► 304 µs to measure all cells in a system
► 16-bit ADC with programmable noise filter
► Passive cell balancing up to 300 mA per channel with program-
mable PWM
► 7 GPIO or analog inputs
► Temperature or other sensor inputs
► Configurable as an I2C or SPI master
► Accommodates ±5 V busbar voltage
Figure 1.
► Sleep state supply current: 5.5 μA
► 48-lead LQFP package with exposed pad
► AEC-Q100 qualified for automotive applications
APPLICATIONS
► Electric and hybrid electric vehicles
► Backup battery systems
► Grid energy storage
► High power portable equipment

GENERAL DESCRIPTION
The ADBMS6816 is a multicell battery stack monitor that measures Multiple devices are connected in a daisy chain with one host
up to six series connected battery cells with a lifetime total meas- processor connection for all devices. This daisy chain can be
urement error (TME) of less than 1.5 mV. The cell measurement operated bidirectionally, ensuring communication integrity even in
range of 0 V to 5 V makes the ADBMS6816 suitable for most bat- the event of a fault along the communication path.
tery chemistries. All six cells can be measured in 304 µs, and lower
data acquisition rates can be selected for high noise reduction. The ADBMS6816 can be powered directly from the battery stack or
from an isolated supply. The ADBMS6816 includes passive balanc-
Multiple ADBMS6816 devices can be connected in series, permit- ing for each cell, with individual pulse-width modulation (PWM) duty
ting simultaneous cell monitoring of long, high voltage battery cycle control for each cell. Other features include an on-board 5 V
strings. Each ADBMS6816 has an isoSPI™ interface for high regulator, seven general-purpose input/output (GPIO) lines, and a
speed, RF immune, long distance communications. sleep state, where current consumption is reduced to 5.5 µA.
For more information about the ADBMS6816, visit the ADBMS6816 product page.
Rev. Sp0
Information furnished by Analog Devices is believed to be accurate and reliable "as is". However, no responsibility is assumed by Analog
DOCUMENT FEEDBACK Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to
change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and
TECHNICAL SUPPORT registered trademarks are the property of their respective owners.
Data Sheet ADBMS6816
NOTES

©2021 Analog Devices, Inc. All rights reserved. Trademarks and Rev. Sp0 | 2 of 2
registered trademarks are the property of their respective owners.
One Analog Way, Wilmington, MA 01887-2356, U.S.A.

You might also like