Technical Data Sheet

ARMORGROUT-70

STRUCTURAL GROUT
We Provide Armor for Building Structures NON-SHRINK CEMENTITIOUS GROUT
FOR UNDER WATER APPLICATION

PRODUCT DESCRIPTION MIXING


ARMORGROUT -70 is a non-shrink cementitious The standard water requirement for
grout for under water application. ARMORGROUT-70 is 3.5-3.8 litres for 20kg bag.
ARMORGROUT -70 is made from carefully In the case of trowellable grout the water
selected proprietary ingredients with impressive requirements is 2.5-2.8 litres for 20kg. However,
anti washout characteristics, good flow and high the correct mix proportion of ARMORGROUT-70
compressive strength. to water is always dependent on the use to
ARMORGROUT -70 scan be used for free flowing which the grout is to be put. Trial mixes should
grouting application and concrete repair under be conducted in small quantity to achieve
water. desired mix specification before use.
BENEFITS ARMORGROUT-70 should be mixed with a drum
mixer or a small drill mixer and allowed to settle
Ÿ Specifically engineered for under water
for three to five minutes to prevent air
grouting and concrete repair
entrapment.
Ÿ There is no major washout of cement phase
when ARMORGROUT 70 is placed underwater SURFACE PREPARATION
Ÿ Non Metallic and Non Staining Surfaces must be cleaned thoroughly, free of
Ÿ Controlled expansion loose and unsound material, cement slurry and
Ÿ High strength and chemical resistant any other deposits. Surfaces must be free of oil,
Ÿ High Flow and Fluidity grease and other membranes. Rusted surfaces
Ÿ Meets or Exceeds ASTM C1107 must be properly grinded or abraded by
USES mechanical means.
Area to be grouted with ARMORGROUT-70 must
Ÿ Pillars
be saturated surface dry that is it must be
Ÿ Dams
saturated with water hours earlier and the
Ÿ Columns bases
surface water must be almost drained before
Ÿ Pile cap re-profiling
application.
Ÿ Gap filling and transfer lines
Ÿ Bridge bearing
YEILD
At standard water content each bag of
ARMORGROUT-70 will yield 9.5 Litres (0.45 cubic
ft) of fluid Consistent grout. The standard water
content for ARMORGROUT-70 is 3.8 litres of
water for 20kg bag.
Approximately 100 bags of ARMORGROUT-70
are required for 1 cubic metre of grout pour.
ARMORSIL MANUFACTURING INCORPORATION
4636 Chestnut Street, Philadelphia, Pennsylvania
Page 1
Tel : +1 209 813 246, +1 415 670 9521
www.armorsil.com, [email protected], [email protected]
Technical Data Sheet

ARMORGROUT-70

STRUCTURAL GROUT
We Provide Armor for Building Structures NON-SHRINK CEMENTITIOUS GROUT
FOR UNDER WATER APPLICATION

PLACEMENT SELF LIVE


ARMORGROUT-70 should be placed by pumping Shelf life is 12 months stored in cool dry place in
or manual pour. Appropriate formwork should be an unopened pack
done that does not allow leakage, to facilitate PACKAGING
ARMORGROUT-70 compaction material should
Materials are packed in 20kg insulated bags
not be vibrated as this may lead to segregation
but rather use rodding at interval of short pours. TECHNICAL INFORMATION
The initial setting time for ARMORGROUT-70 is
Precision Plastic
20-25 minutes and final setting time is25-30 Non-Shrink Grout
minutes. Pot life is 20 minutes Bag size 50 lb (22.7 kg)
The recommended thickness of ARMORGROUT-
Approx. water content
3 qts + 1 pt (3.3 L)
70 in one pour should be between 20mm-50 mm. per bag
Minimum thicknesses should be 10mm and Flow, ASTM C939
maximum thickness per pour should not exceed
Flow, at 5 drops, 100-125
100 mm. Should there be a requirement to pour ASTM C1437
more than 100mm then coarse aggregate should Compressive strength, ASTM C109
be added to increase the thickness and strength
3,500 psi
24 hours
of ARMORGROUT-70. (30.2 Mpa)
As a rule of thumb aggregate to be added should 7 days 9,000 psi
(55.1 Mpa)
not be more than 20% of the grout.
28 days 12,500 psi
Recommended aggregates is the smooth (70.2 Mpa)

rounded aggregrates not more than 10mm in size C-827 expansion 0 - 0.4
Where aggregrates inclusion are not desired,
Height change, ASTM C1090
material can be poured in stages to achieve final
pour of 100mm 1, 3, 7 and 28 days 0 - 0.2 0 - 0.2 0 - 0.2

CURING
As soon as the grouting is completed, it should
be cured immediately. Suitable curing such as
membrane or plastic sheet should be used to
protect freshly applied ARMORGROUT-70.
Curing should continue for 7 days after pouring.
Free water should be removed before pouring
and the grout should be poured continuously so
as to ensure air is not trapped.

ARMORSIL MANUFACTURING INCORPORATION


4636 Chestnut Street, Philadelphia, Pennsylvania
Page 2
Tel : +1 209 813 246, +1 415 670 9521
www.armorsil.com, [email protected], [email protected]
Technical Data Sheet

ARMORGROUT-70

STRUCTURAL GROUT
We Provide Armor for Building Structures NON-SHRINK CEMENTITIOUS GROUT
FOR UNDER WATER APPLICATION

HEALTH AND SAFETY Armorsil Manufacturing supplies products that


This product is hazardous if not used comply with the properties shown on the
appropriately and it must be administered by current datasheets. In the unlikely event that
trained and professional persons. products supplied are proved not to comply
ARMORGROUT-70 contains cementitious with these properties, then we will replace the
content which can be harmful when not non-compliant product or refund the purchase
handled properly and under constant exposure price. Armorsil Manufacturing does not warrant
to eyes. Proper protective equipment should be or guarantee the installation of the products as
used when mixing and using all cementitious it does not have control over the installation or
based materials. end use of the products. Any suspected defects
must be reported to Armorsil Manufacturing in
LIMITED WARRANTY writing within seven working days of being
All recommendations, statements and technical detected.
data herein are based on tests we believe to be
reliable and correct, but accuracy and Armorsil Manufacturing makes no warranty as
completeness of said tests are not guaranteed to merchantability or fitness for a particular
and are not to be construed as a warranty either purpose and this warranty is in lieu of all other
e x p r e s s e d or implied. User shall rely on his warranties express or implied. Neither seller nor
or her own information and tests to determine Armorsil Manufacturing shall be liable to the
suitability of the product for the intended use buyer or any third person for any injury, loss or
and user assumes all risk and liability resulting damages of any sort including remote or
from his or her use of the product. Nothing consequential damages, down time, or delay
contained in any supplied materials relieves the directly or indirectly resulting from use of or
user of the obligation to read and follow the inability to use the product. . The information
warnings and instruction for each product as set contained in the latest data sheet supersedes all
forth in the current Technical Data Sheet, previously published editions. Visits to site by
product label and Safety Data Sheet prior to Armorsil personnel do not constitute
product use away. supervisory responsibility. Armorsil reserves the
right to alter the information contained in this
datasheet without prior notice.