Description Of Item Unit Nos Nos Length Breadth Depth Quantity Remarks
No
1.75 Providing and Fixing silhoutte type grid black/white reveal PART-A CIVIL WORKS
grid with15 mm thick densified tegular edged eco friendly
light weight calcium silicate false ceiling tiles of approved
texture of size 595 x 595 mm in true horizontal level,
suspended on inter locking metal grid of hot dipped
galvanised steel sections (galvanising @ 120 grams per sqm
including both side) consisting of main ‘T’ runner suitably
spaced at joints to get required length and of size 15x42 mm
made from 0.33 mm thick (minimum) sheet, spaced1200 mm
centre to centre, and cross “T” of size 15x38 mm made out of
0.33 mm (Minimum) sheet, 1200 mm long spaced between
main’T’ at 600 mm centre to centre to form a grid of
1200x600 mm and secondary cross ‘T’ of length 600 mm and
size 15 x38 mm made of 0.33 mm thick (Minimum)
sheet to be inter locked at middle of the 1200x 600 mm panel Sqm
to from grid of size 600x600 mm, resting on periphery walls
/partitions on a Perimeter wall angle pre-coated steel of
size(24x24X3000 mm made of 0.40 mm thick (minimum)
sheet with the help of rawl plugs at 450 mm centre to centre
with 25 mm long dry wall screws @ 230 mm interval and
laying 15 mm thick densified edges calicum silicate ceiling
tiles of approved texture in the grid, including, cutting/
making opening“for services like diffusers, grills, light fittings,
fixtures, smoke detectors etc., wherever required. Main ‘T’
runners to be suspended from ceiling using G.I. slotted cleats
of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50
mm long dash fasteners, 4 mm G.I. adjustable rods with
galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at
1200 mm centre to centre along main ‘T’, bottom exposed
RA 03 & Part
FIRST FLOOR
PANTRY CEILINGS 1.00 1.850 0.650 1.20
CABIN CEILING 1.00 3.050 2.450 7.47
HALL FROM SOUTH SIDE TO NORTH 0.00
BAY (1)…. 1.00 4.700 2.050 9.64
BAY (2)…. 1.00 23.400 10.250 239.85
DEDUCTION FOR CABIN AREA -1.00 4.140 3.580 -14.82
GROUND FLOOR 0.00
NEW LAB CEILING 1.00 10.300 7.300 75.19
UPS ROOM CEILING 1.00 4.270 4.070 17.38
1 of 1