X3eTY2 65C Oct2009
X3eTY2 65C Oct2009
Legal Notice
This document is design ed as a diag nosti c tool, primaril y for Konic a Minol ta's support p ersonnel, a nd authorized
service represen tativ es. Konica M ino lta recommends that all service be perform ed by an authorized service
representa ti ve. Users are responsibl e for seeking a dvic e of a Konica Minolta authorized se rvi ce repr esentative
regarding the information, opinion, advice or content of this document.
USER AGREES THAT USE OF THIS DOCUMENT IS A T USER'S SOLE RISK A ND THAT THIS DOCUMENT IS PROVIDED
ON AN AS IS BA SIS WITHOUT WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, WARRANTIES OF TITLE OR IMPLIED WARRANTIES OF MERCHANTABI LITY OR FITNESS FOR A
PARTICULAR PURPOSE, OTHER THAN THOSE WARRANTIES THAT ARE IMPLIED BY LAW AND INCAPABLE OF
EXCLUSION. IN NO EVENT WILL KONICA MINOLTA OR THOSE ACTING ON ITS BEHAL F BE LIABLE FOR ANY
DAMAGES, INCL UDING, WITHOUT LIMITATION, DIRECT, INDIRECT, INCIDENTAL , SPECIAL, CONSEQUENTIAL OR
PUNITIVE DAMAGES ARISING OUT OF YOUR USE OF THIS DOCUMENT.
Description
Unable to select Tray 4 of the LU-202 in the print driver or Command WorkStation™ with a platen installed.
Solution
CAUSE: Without thedocument feederselected as an installable option,LU-202 is not available. LU-202 can be installed as an option but cannot be selected
when printing.
SOLUTION:System softwareand print driverversion 1.0a for the IC-408 areavailable that correct this issue and can be downloaded via the Konica Minolta
Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
The system code posted for download consists of two DVD ISO image files (IC-408_Special System_Software_v1.0a_Fiery.iso &
IC-408_Special_User_Software_v1.0a_Fiery.iso) that will need to burned to DVDs. It is highly recommend to use a file download manager program due to the
size of the image files.
IC-408 v1.0a code does not requires the installation of any of the previous system patches;many of the previous corrections and enhancements have all
been incorporated with version 1.0a.
Although, as with any reload of system software, perform the Fiery® System Updates to ensure that the base OS (Microsoft® Windows XP) is updated with
the required performance and security patches and also please review the Konica Minolta Download Selector for any new IC-408 version 1.0asystem patches
that may have been released.
Please refer to the attached IC-408 v1.0a Release Notes and install addendum. To view a PDF, A dobe Reader® must be installed. Adobe Reader® can be
downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Tony Pizzoferrato, ESS/S SD
Description
When printing a calibration page from ColorWise™ Pro tools or the MFP LCD, the page does not print. There is nomessage on the printer orcontroller that
indicates the job was sent.
Solution
PROBABLE CAUSES:
1. There is a mismatch between the default paper media settings on t he IC-303 and the paper drawer settings on the engine.
The IC-303 ships with default paper settings of Plain, White, 64-74. If the paper drawer of theengine is not set to these same settings, the job will not print
until the drawer is configured to match these settings. There will not be an indication on the IC-303 panel and the job will also not show up in the job list on the
engine. The only place that the problem can be observed from is Command WorkStation™.
To have all jobs print, based on the drawer settings by default, enter t he IC-303 "Launch Configure" through a web browser and edit the PS settings for paper
type "PDL => PS". Paper weight should be set to "Printers Default".
Note :When printing an IC-303configuration page, the paper weight will show as "0" for this setting.
Description
The IC-408 will not boot completely and powers OFF when connected to the bizhub PRO C5500/C6500.
Solution
CAUSE: The IC-408 is not connected to an "Entry" version of the bizhub PRO C5500/C6500.
SOLUTION: The IC-408 is designed for use with the "Entry" version of the bizhub PRO C6500, and ONLY supports that peripheral configuration. If the
controller boots on a "PRO" version of the C6500 and detects unsupported peripherals, it will power itself OFF. The IC-408 will only support a limited number
of peripherals that are only available on the "Entry" system.
Notes :
1.Please see attached configuration sheets for the applicable model.
2. To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
2
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Solution
CAUSE: User name format does not properly identify the user in the domain.
SOLUTION: Enter the user name in the [domain name\user name] format to properly identify the user to allow the SMB connection.
Note : Since the controller is normally not a member of the domain,it is necessaryto identify the domain name with the domain user name to allow the
connection.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Scan to E-mail is not working after upgrading to version 1.1a.
Solution
CAUSE: System Code bug.
SOLUTION:Install 1-YM6LY patch for the IC-303, IC-305or the IC-408. The patch is available for download via the Konica Minolta Download Selector.
1. Login in via www.mykonicaminolta.com .
2. Select the "Service" link located on the top of the page.
3. Select the "SSD (DNA, Drivers, MSDS)" link located on the left.
4. Select the "Continue on to t he SSD Home Page" link located in the middle of the page.
5. Select the "Download MSDS, Drivers, Firmware and more" link located on the left .
SPECIAL NOTE : Solution contribution by Clinton Marquardt, ESS /BSE and Freddie Burnham, Production Print/SSD
Description
IC-408 powers down after booting.
Solution
CAUSE: The IC-408 with system code version 1.0. is installed on an unsupported configuration (Professional configuration), OR version 1.0A or higher is
loaded but unsupported PRO series finisher i s installed
SOLUTION: The IC-408 must be updated to system code version 1.0A or higher to allow operation of the SD-501, RU-503, and/or the PF-701. All other PRO
series finishers are not supported when using the Fiery® IC-408.
Note :See attacheddocumentation for supported bizhub PRO C6500 configurations.To viewthe PDF, Adobe Reader® must be installed. Adobe Reader®
can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
Unable to insert simplex tabs into duplex print job using the IC-408 controller.
Solution
CAUSE: Alimitationwith theIC-408 system code version 1.0system code.
Description
Unable to printsignature booklets (8.5x11S) or any folding operation with 8.5x11S paper from the Fiery® X3eTY2 (IC-408) PostScript driver. "Load 8.5x11
paper" message is indicatedon the bizhub P RO C6500/C5500 LCD and on Command WorkStation®.
Solution
CAUSE: Bug with theIC-408 system code and print driver.
SOLUTION: IC-408 system software andprinter driver version 1.1 areavailable to correct this issue and canbe downloadedvia the Konica Minolta Download
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
3
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Thesystem code posted for download consists of two DVD ISO image files (IC-408 System Software DVD Ver 1.1.iso & IC-408 User-software
Ver1.1.iso)that will need to be burned to twoDVDs. It is highly recommend to use a file download manager program due to the size of the image files. Also,
the IC-408 v1.1 2-DVD setis availablefrom the Konica Minolta Parts department (p/n 45072657).
Please refer to the attached IC-408 Service Manual for information on install procedure.
Notes :
1. Please be sure to print the configuration pages for reference, save and archive any needed print filesand save any color profiles.
2. IC-408 version 1.1 code does not require the installation of any of t he previous system patches; the previous corrections and enhancements have all been
incorporated.
Although, as with any reload of system software, perform the Fiery® System Updates to ensure that the base OS (Microsoft® Windows XP) is updated
withthe requiredperformance and security patches.
3. Be sure to check the Konica Minolta Download Selector for any additional patches thatmay have been released specifically for the IC-408 version 1.1
system code.
4. For driver-based printing, be sure to use the latest printer driver (version 1.1)thatis included with the User software DVD.
5. Please refer to the attachedRelease Notesfor additional information.
6. To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Tony Pizzoferrato, ESS/S SD
Description
Unable to load system software via the Ethernet installer program. The install program starts but the system software hangs up while loading and does not
complete.
Solution
CAUSE: The IC-408 system software version 1.0a and MicroPress® version 1.1 E thernet installer program have a t endency to"conflict" during system
software install.
SOLUTION: Install the IC-408 system software via a USB thumb drive.
Notes :
1. See attached USB thumb drive system software installation instructions. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be
downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
2. If installing system software via a Ethernet cross cable, disconnect the serial cable to the main body and any USB drive during system software install.
3. In the case of a MicroPress® version 1.1 Ethernet installation, load the system software from a PC other than the PC with the MicroPress® software.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Communication is lost between the MFP and controller when navigating through the controller Job list from the bizhub PRO C6500/C5500 LCD operation
panel. The controller button on theLCD will become "grayed out" andthe controller must berestarted.
Solution
CAUSE: A bug with the IC-408 system code where the communication is lost between the MFP and the controller when navigating the controllers Job List
(Held and Printed jobs) from the MFP's LCD panel.
SOLUTION: A patch is available (1-WSUG3) for the IC-408 that corrects this issue and canbe downloadedvia the Konica Minolta Download Selector. Access
the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
1.Notes :
This patch is specific to IC-408 version 1.1 system code and is not applicable to earlier versions of system code. Please be sure to have the IC-408 at
system code version 1.1 prior to installing this patch.
2. Please refer to the attacheddocumentation for more information. To viewthe PDF, A dobe Reader® must be installed. Adobe Reader® can be downloaded
for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Tony Pizzoferrato, ESS/S SD
Description
Unable to print. A ‘Please Confirm Authentication Setting of Administrator Setting or Controller’ error message is displayed on the operation panel’.
Solution
CAUSE: ‘Allow printing from’ is set to Authorized Users on the Fiery®.
SOLUTION: Set ‘Allow printing from’ to All Users. To set ‘Allow printing from’ to All Users perform the following:
1. Browse into the Fiery®.
2. Launch Fiery® configure.
3. Check the Allow users to print without authentication check box.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
4
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Description
TFTP ERROR UNABLE TO OPEN SOCKET messagewhenupdating system code.
Solution
CAUSE: Incorrect or failed Ethernet crossover cable, or poor connection between laptop and IC-408.
SOLUTION: Connect the laptop used for the system code update directly to the IC-408 with an Ethernet crossover cable. Confirm that the Ethernet cable is a
crossover cable and that it is not damaged.
Note :See attached documentation for IC-408 installation instructions.To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be
downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
FreeForm® master does not match error message in the log when printing a mail merge using FreeForm®.
Solution
CAUSE: System 8 Fiery® controllers will not auto rotate to correctly orientate the print job with the FreeForm® master.
SOLUTION: Make certain that all the size and orientation settings are the same between the FreeForm® master when it is sent and the mail merge when it is
sent.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD
Description
The 1-V80PE patch does not work properly for the Fiery® IC-408 v1.0a.Itdoes not show up on the Fiery® Configuration Page and does not allow any
additional patches to be installed.
Solution
CAUSE: Updated patch required.
SOLUTION: The srcinal patch has been removed from the KMBS SSD Download Selector andanother version of 1-V80PE is available. To verify between
old and new,check the file properties: Right-click => Properties; the file size of the bad patch is 1.51MB ( 1,585,202 bytes ) and the file size of the
good patch is 1.51MB ( 1,590,397 bytes ).
Note : There are currently 5 patches available for the IC-408 v1.0a code (see attached list). Patch 1-V80PE and 1-VA0ZQ are the same; 1-V80PE is for the
bizhub PRO C6500 and 1-VA0ZQ is for the bizhub PRO C5500. Please be sure to read the release notes carefully as the install process does vary between
patches.
Also, attached is a configuration page fromthe SSD/ESSIC-408 installed on a bizhub PRO C6500, the first 4 patches were manually installed and all the rest
are from performing the system updates.
Description
Jobs deleted from Fiery® if jam or no paper error is not cleared within specified time. Job will leave Active Jobs queue and then show in the Printed Jobs
queue as an errored job.
Solution
CAUSE: Cancel Job on paper mismatch is enabled on Fiery® and timeout settings are at lower minute setting.
SOLUTION: Disable the Cancel Job on Paper Mismatch or increase timeout setting by using the following procedure:
1. Connect to the Fiery® using a web browser.
2. Select Web Tools.
3. Click on the Configure tab.
4. Click on the Launch Configure tab.
5. Enter the Fiery® password. The default password is 'Fiery.1'.
6. Select Server.
7. Select Jobs.
8. Under Job mismatch, uncheck the Enable Mismatch Action check box, or increase timeout setting to desired amount.
9. Click Apply.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
5
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Description
IC-408 powering OFF after booting up with a display of FF.
Solution
CAUSE:Green LED reset pushbutton is stuck in the activated position.
SOLUTION: Check to see if the green LED reset pushbutton, to the right of the ON/OFF switch, is stuck inward. Open up the Fiery® and release the stuck
button. Add tension on the return spring if needed.
SPECIAL NOTE : Solution contribution by Freddie Burnham, Production Print/SSD
Description
"Press Start to restart" message when printing on custom size paper with no finishing options installed using either the IC-408 or IC-305.
Solution
CAUSE: Special firmware required.
SOLUTION: Install special Image firmware version GCB-30 for bizhub PRO C6500, orGCB-12 for bizhub PRO C5500 to correct this issue. The latest version
firmware or system software is available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by
clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by David Aekus, Production Print/SSD
Description
Controller internal pages are not printing. These pages are never shown in the Job List on the machine or in Command WorkStation™.
Solution
CAUSE: Publish Direct Connection is set to “No” in the Printer Setup.
SOLUTION: Set Publish Direct Connection to “Yes” in the Printer Setup section of the Fiery® configuration.
SPECIAL NOTE : Solution contribution by John Mcilreevy, Pacific Office Automation.
Description
After the i-data box has been powered OFF/ON, it does not reattach to the AS/400® via TN5250E.
Solution
CAUSE: The i-data device was not varied offline which allows the TN5250E protocol to connect to the AS/400®.
SOLUTION: Vary the i-data device offline to allow the TN5250E protocol to connect to the AS/400®.
The Netstat command can also be used to determine if the AS/400® 'thinks' that the i-data box is still connected. Locate the TCP/IP address of the box in the
Connection Status screen, and end the connection. Recycle the i-data box and it should connect.
SPECIAL NOTE : Solution contribution by Mark D'Atti lio, Production Print/SSD
Description
"ACCESS CODE INVALID" message when printing from Microsoft® Windows 95/98/ME through a Windows 2000 or 2003 server. Printing from Windows
NT/2000/XP through the same queue is fine.
Solution
CAUSE: A possible corrupt spooler that only affects printing from non-NT based workstations.
SOLUTION: Delete the printer and all associated driver files and then reload the drivers. For more detail, refer to Microsoft® Knowledge Base Article -
260737 .
Note : To view the above PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.htm
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
6
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Description
Unable to scan; Scan button is "grayed out".
Solution
CAUSE: Scanner function is prohibited.
Description
“The client could not connect to remote computer”message and unable to connect to the Fiery® using the Remote Desktop connection.
Solution
CAUSE: Remote Desktop is disabled at the Fiery®.
SOLUTION: Enable the Remote Desktop connection. To enable remote desktop, perform the following:
1. Select Controller from the machine screen on the bizhub PRO C5500/C6500 LCD panel.
2. Enter thecontroller password (the default password is Fiery.1 ).
3. Select Setup.
4.Select Server Set Up.
5. Select Enable for Remote Desktop.
6. Select Back.
7. Select OK.
8. Select Apply.
9.Reboot.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Unable to load system code. An "Unable to Open Socket Timeout Error" is indicated.
Solution
CAUSE: A manually configured TCP/IP address is set on the computer used to load the system code.
SOLUTION: Enable DHCP for the network adapter being used to load the system code on the Fiery®.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Files on a USB thumb drive do not print when it is inserted into the controller.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
7
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Solution
CAUSE:The USB port is disabled under network setup by default.
SOLUTION:Access Fiery® setup and enable USB port under Network setup and then configure it.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD
Solution
ID TAUS0657643EN* Solution
Usage
Description
Unable to scan to FTP.
Solution
CAUSE: FTP function is prohibited.
Solution
ID TAUS0703247EN* Solution
Usage
Description
How to increase the viewed amounts of jobs held in the Job Log on Command WorkStation™.
Solution
This can be done in the S erver Setup of the Fiery®:
1.Enter the Server Setup of the Fiery® (password Fiery.1) via the web browser and TCP/IP address or at the machine/controller.
2.Under the Server Setup there is a category “Jobs Saved in Print Queue”. Enter 1 t o 99.
3. Save and re-boot the controller in order for the changes to take effect.
SPECIAL NOTE : Solution contribution by Freddie Burnham, Production Print/SSD
Solution
ID TAUS0800364EN* Solution
Usage
Description
Unable to print a configuration page and the machine prompts for 64gms to 74gms paper weight yet the tray is set for t he proper paper weight. This problem
also occurswhen printing.
Solution
CAUSE: The firmware on the machine is corrupt or the system code on the IC-408 is corrupt.
SOLUTION: Upgrade the firmware on the machine to at least version 12 and the IC-408 system code to version 1.0a. The latest version firmware or system
software is available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS E xpert Support) by clicking on 'Download
MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Mark D'Attil io, Production Print/SSD
Solution
ID TAUS0800398EN* Solution
Usage
Description
Scan to Windows SMB is not shown on the IC-303/IC-408 configuration page.
Solution
CAUSE: Windows printing is disabled on the IC-303/IC-408.
Solution
ID TAUS0800409EN* Solution
Usage
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
8
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Description
Patch installation using Command WorkStation™ fails.
Solution
CAUSE: Patches are executables using a built-in Fiery® Downloader.
SOLUTION: Download the patch and either unzip or execute. Open the resulting folder and run the executable file.The following information is required:
Username: admin
Password: Fiery.1
Hostname: The TCP/IP address of the Fiery®.
Follow the onscreen prompts when installing.
Note : Patchescan usuallybe downloaded fromthe Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by
clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD
Solution
ID TAUS0800485EN* Solution
Usage
Description
CANNOT RECOGNIZE VIDEO BOARD error message and printcontroller not recognized by main body in Command WorkStation™ after installing the
1-UY7PG patch on system version 1.0.
Solution
CAUSE: Patch 1-PYRSX has not been installed.This patch must be installed at the same time, as stated in the Release Notes.
Solution
ID TAUS0801189EN* Solution
Usage
Description
Unable to print anything from IC-408 including configuration page after loading version 1.1.
Solution
CAUSE: Version 1.1 defaults to a paper type of Color Specific which requires the trays to be manually configured or overridden.
SOLUTION: In the PostScript setup section of the Fiery® setup of the web browser, set the paper type to Plain as a default.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD
Solution
ID TAUS0801354EN* Solution
Usage
Description
Unable to log onto Fiery® remote scan using the default user name and password (admin/Fiery.1).
Solution
CAUSE: LDAP is enabled.
SOLUTION: Enter any valid LDAP Username and Password to enter Fiery® Remote Scan. Disable LDAP on the Fiery® under Service set up.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0801427EN* Solution
Usage
Description
When theproperties of a job are opened in the P rinted Jobs area in Command WorkStation™ version4.5.21 and then either the PRINT or OK button is
pressed, these errors occur i n succession:
Error: Spine Width
Numeric value must be between 0.00 and 85.00
Solution
CAUSE: Corrupt Fiery® program(s).
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
9
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
SOLUTION:All Fiery® programs must be removed form theworkstation using the uninstall utility on Fiery® disc. The Fiery® utility disc must be the
sameversion as the version of system codeinstalled on the Fiery®. For example, if you have version 1.01 on the Fiery® you would use the version 1.01
Fiery® utility disc.
After all programs are removed, reinstall using the Fiery® utilities disc.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0801505EN* Solution
Usage
Description
Configuration page 2 will not print. Command WorkStation™ displays PostScript error.
Solution
CAUSE: IPv6 enabled.
Solution: Set Enable IPv6 toNO in the Network setup => Protocol setup.
SPECIAL NOTE : Solution contribution byWiiliam Monnot, KMBS /Hawthorne
Solution
ID TAUS0801668EN* Solution
Usage
Description
After updating the IC-408 to version 1.1, unable to print andfinishing options and features not available.
Solution
CAUSE:Correct PPD has not been loaded in Adobe® PageMaker® or PPD has not been assigned to printer in PageMaker® print dialog box.
Solution
ID TAUS0801779EN* Solution
Usage
Description
Unable to print a calibration test page and configuration page as well.
Solution
CAUSE: The IC-408 system code is corrupt.
Solution
ID TAUS0802208EN* Solution
Usage
Description
Scan function goes offline.
Solution
CAUSE: Network speed not changing automatically. Not sensing the customer's switch speed.
SOLUTION:On the Fiery®, change the network speed from "auto" set to 100Mbps Half-Duplex or 100Mbps Full-Duplex (refer to attached photo).
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0802615EN* Solution
Usage
Description
Slow print speed to the IC-408/bizhub PRO C6500.
Solution
CAUSE: Pre-release PrintStation Manager™, build 8282 is installed on the MicroPress® server.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
10
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
SOLUTION: Install the official release PrintStation Manager™, build 8283 on the MicroPress® server.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0802825EN* Solution
Usage
Description
Code 91 or code 92 is indicated on the Fiery®.
Solution
CAUSE: System software has not been updated, the motherboardmay have failed or the wrong motherboard was ordered.
SOLUTION:Reload Fiery® system software.If the code returns,make sure that the Motherboard (p/n 45068302) and Hard Disk (p/n 45053589) are replaced at
the same time.
Note :If swapping a motherboard from another Fiery® make sure to also remove the hard drive.If the motherboard is replaced and there is no harddrive
available,please contact the SSD Hotline (800-825-5664) andthey will contact EFI® for a special dongle (this dongle removes all BIOS data from one
motherboard and installs it to another).
A newmotherboard comes with instructions and a Service Dongle.
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0808209EN* Solution
Usage
Description
TLS error occurs when scanning to E-mail with the IC-408 running version 1.1 system code.
Solution
CAUSE: The IC-408 is missing patch file 1-YM6LY
SOLUTION: Install attached patch file 1-YM6LY. Please refer to att ached Release Notes prior to patch installation. To viewthe PDF, Adobe Reader® must be
installed. Adobe Reader® can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Gary Scimeca, Production Print/SSD
Solution
ID TAUS0900112EN* Solution
Usage
Description
When scanning through the Fiery® controller, the scan has a mono-colored background. Copies and prints look f ine.
Solution
CAUSE: The Fiery® interface cable is not seated properly.
SOLUTION: Shut down the Fiery® controller, unplug the MFP, and reseat the Fiery® interface connection to the MFP.
SPECIAL NOTE : Solution contribution by Gary Scimeca, Production Print/SSD
Solution
ID TAUS0900256EN* Solution
Usage
Description
Authentication failure message when printing after updating the system software.
Solution
CAUSE:Machine is set to prohibit for print under without authentication of the Authentication/Account Tracksection.
SOLUTION:To set the main body for permission to print without authentication perform the following:
1.Enter Machine Manager.
2. Select User Authentication/Account Track.
3.Select Without Authentication.
4. Set Print to P ermission and save the setting.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD
Solution
ID TAUS0900740EN* Solution
Usage
Description
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
11
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Solution
CAUSE: Possible Two-Way Communications is enabled.
Solution
ID TAUS0900764EN* Solution
Usage
Description
Fiery® network ports for systems 8 and 8e.
Solution
Network Ports
TCP
UDP
Port Name
Dependent Service(s)
80
HTTP
WebTools, IPP
123
NTP
135
MS RPC
137-139
NETBIOS
Windows Printing
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
12
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
161, 162
SNMP
445
SMB/IP
515
LPD
LPR printing, some legacy utilities (such as WebTools, older versions of CWS)
631
IPP
IPP
8021-8022,
21030
9906
Harmony
CWS4, Velocity, EFI SDK-based tools, Fiery® Printer Driver bi-di functions
9100-9103
Printing Port
Port 9100
Fiery® Remote Scan 5 falls into the TCP ports8021-8022, 21030 and UDP 9906.
Note : Please see the attached Fiery® Security White Paper for detailed information. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader®
can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0900893EN* Solution
Usage
Description
Unable to calibratethe Fiery® using an ES-1000 or to print Measurement page.Although, able to print and view web page.
Solution
CAUSE: Corrupted system software.
SOLUTION: Please load system software version 2.0 or later. The latest version firmware or system software is available via the Konica Minolta Download
Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
13
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
Solution
ID TAUS0901046EN* Solution
Usage
Description
"Freeform DSC Incorrect. Contact Your FF Application Vendor" message is displayed in Command WorkStation™ when printing a variable data job using a
FreeForm™ template.
Solution
CAUSE: The FreeForm™ template being used for varyable data printing is corrupt.
SOLUTION: Delete the corrupt FreeForm™ template from the controller, then recreate it and import t he new template back into the controller.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0901435EN* Solution
Usage
Description
Unable to restart a paused print job when print from Macintosh® OS 10.x.
Solution
CAUSE: This problem has been identified withIC-303, IC-305 and IC-408system code versions 1.1 and below.
SOLUTION: Upgrade the Fiery®to version 2.0 system code or later. The latest version firmware or system software is available via the Konica Minolta
Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0901841EN* Solution
Usage
Description
Document cannot be added to controller using FreeForm™.
Solution
This issue has been escalated to Konica Minolta Business Technologies in Japan.
KMBS/SSD is working with our partners in support in Japan to obtain a resolution for this issue as quickly as possible.
Note : If viewing this solution via the web, please establish a ticket via either the web or by calling the SSD hotline center at 1-800-825-5664. Once a ticket
has been established an E-mail will be sent when the solution is updated.
For phone advisors, please attach to this solution for an automatic E-mail that will be sent to the technician when this solution is updated. E nd the call with
call code "Escalated to Japan".
SPECIAL NOTE : Solution contribution by Paul Santangelo, ESS/SSD
Solution
ID TAUS0901968EN* Solution
Usage
Description
When trying to scan a 2-sided srcinal to HDD or E-mail, the 2-sided button is "grayed out" on theMFP control panel.
Solution
CAUSE: The initial scan setting does not see the ADF is installed.
SOLUTION: To allow the initial scan setting to see t he ADF, perform the following:
1. Press Utility.
2. Select User.
3. Select Initial Setting.
4. Select Scan Initial Setting and select ADF at the bottom of the screen.
5. Exit the Utility mode.
SPECIAL NOTE : Solution contribution by Gary Scimeca, Production Print/SSD
Solution
ID TAUS0902419EN* Solution
Usage
Description
Scan does not reach the destination or is corrupt after calibration.
Solution
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
14
I C-408 Controller -no or slow print,scan failure,garbled data,lockup
SOLUTION: Install the attached special patch software version 1-13IGLD.The patch is also available via the Konica Minolta Download Selector. Access the
Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Notes :
1.Please review theattached Release Notes prior to patch installation.To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be
downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
2. To open the ZIP file WinZip® should be installed. WinZip® can be downloaded from the WinZip® website: http://www.winzip.com/ddchomea.htm . The file
can either be saved to disk or opened. It is recommended to download the ZIP and open from the local computer to view.
SPECIAL NOTE : Solution contribution by Stu Dern, ESS
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
15
I C-408 Image
blank
or
solid
color
Description
Print quality issues:
Solution
CAUSE: The Quark® document or PDF has overprints in it, which is why it is printing a black box instead of the graphic underneath the overprint.
Overprint Explanation:
Overprinting is another way to guard against mis-registration in process color printing. When two different-colored objects overlap in process printing, the
bottom object is normally cut away during printing. This ensures that the color of t he top object and the color of the bottom object do not mix or blend. This
method of printing produces clean, uncorrupted colors just as you assign them in Illustrator®. The downside is that if registration is slightly off, odd spacing or
awkward overlapping will occur between the objects.
By assigning overprinting, you can add the color of a top object to that of a bottom object when objects overlap. The printed result is less vulnerable to
mis-registration.
This issue typically will apply to QuarkXpress® version 6.5/7.0, InDesign® CS2/CS3 or Acrobat® version 7/8/9. It also may not be a black box with a TIF file.
It may be missing graphics/text or transparent colors being rendered as solids. This can apply to different graphic formats besides TIFF.It could be vector
graphics or EPS files as well.
In terms of the print dialog box for output, it should be set to Composite CMYK and Spot. You do not want to convert all of your colors to RGB in a print
environment. There are times when you might want to useonly Composite CMYK and convert all of your Spot colors as they will not render correctly if they are
under a transparency layer.
SOLUTION: To correctly render the overprint as a transparent layer, "Composite Overprint" must be checked under the ColorWise® settings in the driver.
Enabling Composite Overprint renders a correct image
Note : Please see attachment for samples and details. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free
from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
16
I C-408 Image
delay,
advance,
shiftorskew
Description
Colors are shifting after every calibration.
Solution
CAUSE: Patch upgrade required.
SOLUTION: The IC-303 1-TP12R patch has been released. Install the IC-303 1-TP12R patch.
Notes :
1.See attached ReadMe document for additional detail. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free
from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html
2. The latest version firmware or system software is available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS
Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
17
I C-408 Imagetoolight,dark,unevenorwrongcolor
Description
When printing, one of these image problems may occur:
negative image
color is greatlymisaligned
a pattern is printed in the background or there are missing images
Solution
CAUSE:Electrical noise (interference)when sending and receiving the data in the MFP possibly due to:
an incomplete connection between theMFP and cable or the controller and cable.
system code.
a failed IPB.
Failed IPB
Replace the IPB (p/n A03U H020 28).
CAUTION : For a bizhub PRO C6500/C5500 withthe EFI Fiery ® controller, replace the IPB (p/n A03U H020 28) and Fiery® I/F board (p/n 45053205) as a
set .
Notes :
a. Both the MFP and the controller have a circuit on the interface; changing both boards is recommended.
b. I/F boards have been modified (Rev.D). Please refer to the att ached EFI Cut-in Serial Number List. To view the PDF, Adobe Reader® must be installed.
Adobe Reader® can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
IMPORTANT : This pertains to the bizhub PRO C6500\C5500 ONLY . The bizhub PRO C6501 IPB is already modified.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD;Jim Behrends, Workgroup/SSD and Clinton Marquardt, ESS
Description
Text print font is bold.
Bold Text
Solution
CAUSE: The Fiery® is set to Normal. When composing text which is specified as black, the color can be made up from a combination of CMYK which is
referred to as Rich Black, or just from the black component which is referred to asPure Black.
Rich Black often prints oversaturated and uses more toner than necessary. It can also spread fine text and mis-registration may become obvious.
When set to print Pure Black, the text and graphics appear less saturated but can look cleaner as less toner is usedto produce the black.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
18
I C-408 Imagetoolight,dark,unevenorwrongcolor
Solution
ID TAUS0800561EN* Solution
Usage
Description
PANTONE® colors printed from an application do not match the PANTONE® swatch book.
Solution
CAUSE: Incorrect use of Fiery®color charts.
Solution
ID TAUS0802211EN* Solution
Usage
Description
Magenta background when printing.
Solution
CAUSE: Corrupted system software or bad IPB.
SOLUTION:Update theMFP firmware to latest firmware level.Reinstall the Fiery® system software.If t he problem persists, replacethe Image Process Board
(p/n A03UH02015).
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0802361EN* Solution
Usage
Description
Spot-On with Substitute Color is not changing the color of an image to the selected color.
Solution
CAUSE: The image is a raster image.
SOLUTION:Color substitutions affect only text, vector, and line art. They have no effect on raster images.
SPECIAL NOTE : Solution contribution by Ian Lynch, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
19
I C-408 Image
voids
or
deletions
Solution
ID TAUS0808534EN* Solution
Usage
Description
Some or all CMYK colors channels are missing while printing from the Fiery® (see attached sample).
Solution
CAUSE: Possible incorrect settings or malfunction of controller.
4.Note
Select Factory
: Other Defaults.
things to lookfor to resolve the problem:
the interface cable from the controller to the machine - check for any bent pins and reverse the cable if possible.
Open up the controller and reseat all boards and connectors.
Reload system code and all patches. The latest version firmware or system software is available via the Konica Minolta Download Selector. Access the
Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Freddie Burnham, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
20
IC-408 Miscellaneous
Description
What Konica Minolta printer drivers will come bundled with Microsoft® Windows Vista™ and what is the release schedule for Vista™-compatible drivers?
Solution
Please refer to the Windows Vista™ Hardware Compatibility List for Printers & Scanners.
For EFI legacy products that will not receive a Vista™-specific driver, refer to the following statement:
"The previous drivers ( System 5/5e-8/8e ) will not work on 64-bit Vista™. However, these drivers will work on the 32-bit version of Windows Vista™ with
minor issues."
Known issue : Borders and frames around icons and panes within the driver UI may not show up correctly.
Notes :
1. If a previous driver was Microsoft® Windows XP WHQL certified, Microsoft® also honors the digital signature (CAT file) on Windows Vista™.
2. The latest print drivers are available via the Konica Minolta Download Selector. Access the Selector from the KMBS public site
(http://www.kmbs.konicaminolta.us) Support & Drivers tab or from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers,
Firmware and more'.
3. The Windows Vista™ Compatibility Legend can be viewed at: http://kmbs.konicaminolta.us/content/support/vistasupport.html
4. Refer to the attached document for a list of Konica Minolta printer drivers that come bundled with Microsoft® Windows Vista™. To view the PDF, Adobe
Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Bill Ehmke, ESS/SSD and Jim Behrends, Production Print/SSD
Description
Part number(s) for the IC-408 system code.
Solution
IC-408 system codeversion 1.0(p/n 45057679), version 1.0a (p/n U226-0190 - 2 DVD set),version 1.1 (p/n 45072657) and version 2.0 (p/n 45079926).
IMPORTANT :There is alimited supply of the IC-408 version 1.0a system code DVDs, thus availability isnot a certainty.
All the ISO files to create a DVD (or DVDs)are available for download via the Konica Minolta Download Selector. Access the Selector from SSD Web Support
(CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Please refer to the Release Notes and installation instructionswhich also are available via the Download Selector.To view a PDF, Adobe Reader® must be
installed. Adobe Reader® can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Freddie Burnham, Production Print/SSD
Description
Scan to SMB setup instructions for the Fiery® IC-303 and IC-408.
Solution
Please refer to the attached documentation. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the
Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez and David Aekus, Production Print/SSD
Description
How to install system code on the IC-408 through the Ethernet port or USB flash drive.
Solution
ETHERNET LOAD
Version 2.0 systemsoftware or higher can be run directly from the DVD;
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
21
IC-408 Miscellaneous
1. Disconnect cables from Fiery® and power it down. Power downthe MFP using sub-switch.
2. Double-click on Fiery® Installer.exe.
3. Flip both DIP switches (one inch away from LED display on Fiery® - sometimes covered by gray tape).
4. Approve license screen and Ethernet connection screen.
5. TurnON the Fiery® power switch and wait 15 seconds or so until "FF" is seen on t he Fiery® LED (green switch light must be ON). Within 2-3 minutes "1 of
12" will show on installer screen.
6. This will take 35-50 minutes.
7. Once "12 of 12" is done, with status bar not moving and "0KB" visible, click "Finish".
8. Ignore verbiage in installer, power down Fiery® using the AC switch, reset DIP switches to srcinal, then power down the MF P using the main sub-switch.
9. Reconnect normal cables, power up the MFP, then the Fiery® AC switch making sure the green soft-switch light goes ON.
10. At this point it can take the Fiery® up to 60 minutes to complete self-install. When the Fiery® is done the "Controller" button on the MFP LCD is active
and "00" is seen on Fiery® LED.
11. Set up the Fiery® partially through the MFP interface, or via Web Configure (more settings).
Notes :
Video port is totally dead when monitor is connected to Fiery® VGA port.
The documentation states that the controller button will appear after about 60 minutes. During testing, waiting 70+ minutes, "Controller" button never
appeared. But as soon as the controller and the MFP are powered up again, it does. Recommend following the above procedure (step i).
Flash drive and Fiery® LED behavior while transfer from flash drive to Fiery® (steps d and e above):
On initial power up, for about 20 seconds, there willbe rapid Fiery® LED changes and the flash drive will flash a few times. Then, Fiery® LED will count 00,
01, 02 ... 13, 14, FF(changing values about every 30 seconds or so). Once the flash drive stops blinking and Fiery® LED has not changed from "FF", transfer
is complete. The IC-408 Service Manual, pages 50-61, covers this procedure (see attached).
To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
SPECIAL NOTE : Solution contribution by Ed Bellone and Gregg Gallant, Production Print/SSD
Description
How to install system software on the IC-402 (Fiery® X3eTY 35C-KM), IC-406 (Fiery® X3eTY 30C-KM) or IC-408 (Fiery® X3eTY2) using a USB flash drive.
Solution
Please see the attacheddocumentation for complete instructions.To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for
free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
Note :Make sure to powerOFF the Fiery® usingthe dedicated AC switch; disconnect all cables from the Fiery® andverify that the Service Switches are in
the normal position (downward position).
IMPORTANT : Normal isDIPSW in the Downward Position and Service isDIPSW in t he Upward Position.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD and Cesar Jimenez, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
22
IC-408 Miscellaneous
Description
How to create saddle-stitched booklets on t he bizhub PRO C6500/C5500 from Macintosh® OS 10.4x and Microsoft® Windows® XP.
Solution
The attached document details how to make a saddle-stitched booklet using the IC-303 print driver from Macintosh® OS 10.4x and Microsoft® Windows®
XP. These should also apply to other versions of Microsoft® Windows and Macintosh® OS 10. The document procedure was as tested with Adobe®
Acrobat®.
Notes :
1. The IC-408 works the same way with minor differences in features in the screen shots.
2.When printing from Microsoft® Word, there is a known issue that prevents the job from printing on the correct size paper without configuring the document
in Word correctly on controllers with system software prior to 1.02.
The page size must be defined as 8.5x11S and the "Scale t o paper size" option in the Word print dialog box must be set to 11x17. "Booklet Best Fit" must
also
job tobe selected
the in theon
hold queue print
thedriver
Fiery®options to get
and then uset he page to fit
Command within the margins.
WorkStation™ Thisthe
to change will paper
result size
in a slightly
to 11x17.reduced image.
This will resultThe
in aother option
properly is to print
scaled sendjob,
the
but requires this extra step.
3. Version 1.02 system code does not require the Scale to paper size option in the Word print dialog box to be set to 11x17. Instead set it to either "none" or
8.5x11S. This will output an image that is not reduced.
4. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Jim Behrends, David Aekus and Ed Bellone, Production Print/SSD
Description
IC-408 parts list includes:
HDD cable
2.8GHZ CPU
Power Supply
Fan Assembly
Motherboard
Solution
Please refer tothe attached updated Bulletin Number 5797. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free
from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
Also view the attached photos as reference.
Note : The motherboard part number in the srcinal bulletin mistakenly showed it as being commonwith the IC-405 and IC-406. Thepart number for the
IC-408 motherboard is now listed correctly.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD and Bill Ehmke, ESS/ SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
23
IC-408 Miscellaneous
Description
Paper Test requirements.
Solution
For initial test the dealer/branch must supply 1000 sheets of the media paper. Once the paper is received the ticket is transferred to ESS.
If the initial test does not have any issues then a second test can be done. The dealer/branch must supply enough media to cover 1/3 of a P M cycle. There is
a charge involved to cover labor and supplies. The dealer/branch will be notified byESS before the test to communicate the charges.
SPECIAL NOTE : Solution contribution by Cesar Jimenez and Ian Lynch, Production Print/SSD
Description
How to install Fiery® Impose™ software.
Solution
The Impose™ software is automatically installed when you install Command WorkStation™ Microsoft® Windows® Edition from the User Software DVD.
CAUTION :Do not attempt to install Impose™ manually from the User Software DVD (by starting the setup.exe from the Impose™ folder). Installing
Impose™ separately from Command WorkStation™ can cause unpredictable results.
To enable Impose™ on a client workstation, install Adobe® Acrobat® and the Enfocus PitStop™ plug-in module (the Adobe® Acrobat®/Enfocus PitStop™
CDs are provided in the Impose™ Media Pack);install the Impose™ software protection key (dongle) into the correct port of the client workstation (the
protection key may be either a parallel port type or a USB type dongle).
Without a dongle installed, use Impose™ in Demo mode. Demo mode allows documents to be imposed and saved, but all printed output displays a “Demo”
watermark.
Notes :
1. All EFI Fiery® System 8e has Impose™ already available (without a dongle you will get watermarks across all pages).
2. Impose™ will not work if you are using PCL drivers (use PostScript drivers).
3. Processed and Held jobs cannot use Impose™ (Remove Raster Data).
4. Please use Command WorkStation™ version4.6.0.31 or later.
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Description
How to enableFiery® System Updates automatically.
Solution
To enable Fiery® System Updates automatically, follow these procedures:
1. Connect to the Fiery® using a Remote Desktop connection. The User name and password is ‘Administrator’ and ‘Fiery.1’.
2. Select Start => All Programs => Fiery => System Updates.
3. Select Check Important System Updates, then select the time and f requency.
4. Select Automatic for both Operating System and Fiery® System.
5. Configure the proxy server settings if a proxy server used for the Fiery® Internet connection.
6. Select Check now to install available updates. Once updates begin downloading, they cannot be interrupted or stopped.
7. Exit Remote Desktop.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Requirements needed for testing and escalation to SSD or ESS of print quality or related issues for Fiery®, CREO©, Emperon and applications.
Solution
Requirements are:
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
24
IC-408 Miscellaneous
Solution
Follow the How to remove Macintosh OS X drivers instructions to correctly remove driver files prior to installing a new or updated version of the driver. This
is highly recommended to avoid driver conflict.
Completely deleting\removing the PPD plug-ins for the loading of the driver will NOT overwrite the previous versions.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Bill Ehmke, ASG/SSD and Freddie Burnham/Mark D'Attilio, Production Print/SSD
Description
IC-408 motherboard replacement information.
Solution
ISSUE 1 : There was a motherboard replacement kit (p/n 45054305 )when version 1.0 system code for the IC-408 was first released. Thispart numberis
invalid for IC-408. It isONLYvalid for IC-402/IC-405/IC-406/IC-409 family of Fiery® controllers .
This difference is that the Microsoft® Windows XPe-based IC-408 kit is supposed to ship with a BIOS chip on the replacement board, whereas the kit for the
above-mentioned Linux-based Fiery® controllers does NOT have the BIOSon t he replacement board.
ISSUE 2 : Shortly after the release of the IC-408 system code version 1.0, a serious bug was foundthat would prevent the motherboard kit from working if it
was ever needed.Therefore, if any version 1.0 IC-408s in field had motherboard failures, the entire IC-408 would have to be returned (RMA’d).
The system software fix to allow motherboard replacements to work was built into the Fiery® IC-408 version 1.0a and version 1.1 system code. If a
motherboard was to be replaced on one of these two versions, that motherboard kit part number would be 45068302 .This isa unique part number that is not
common across any other system.
The replacement is similar to that of the external controllers asthere isa dongle to transfer all of the features to the new board.
EFI has stated that this dongle will not function if the controller is at version 1.0 when it is replaced.
It must be at version 1.0a or higher for the transfer to function. They recommend an RMA of the whole controller if at version 1.0 when a failure occurs.
If there are no options on the controller that must be transferred, this should not be an issue.
Note : Please use the attached Motherboard Replacement Procedure. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be
downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
IMPORTANT :If an RMA is required, a SSD ticket must be opened and transferred to the applicable DSM.Additionally all IC-408s in t he field should be
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
25
IC-408 Miscellaneous
Description
Support for Account track, Secure print, and User authentication from Unix/Linux environments.
Solution
Konica Minolta does not support Account track, Secure print, and User authentication from Unix/Linux environments at this time.
The availability of these options for Unix/Linux environments is being considered for future development.
Please attachticket to this solution and provide the following information;
1. Product model number(s).
2. Now many products placed or being considered for placement.
3.What "flavor" and version of Unix/Linux operating system.
SPECIAL NOTE : Solution contribution by Tony Pizzoferrato, ESS/S SD
Description
How to load a 64-bit driver on a 32-bit Server system (Microsoft® Windows 2003 Server/Vista™).
Solution
Please follow this step-by-step procedure and refer to the attached video.
1. Load the 64-bit driver on the client.
2. Load the 32-bit driver on the server and share it out.
Note : If you receive a pop-up indicating “COPY ERROR”, setup cannot copy this file. Example: KOZJA_.PP_. This could possibly be a file path length
limitation. Try reducing this limitation by pulling out t he specific driver needed and placing it on the desktop.
3. From the 64-bit client perform the Run command to connect to the 32-bit server (example: \\11.11.5.33) and press enter.
4. Double-click on the shared out printer.
5. Select printer and then properties.
6. Select the Sharing tab and click on the additional drivers box.
7. Select or check-off the 64-bit (x64) driver to be added to the 32-bit server.
8. Select OK and the 64-bit driver should be pushed up to the server.
9. Check the additional drivers of the client and server to confirm that t he x86 (32-bit) and x64 are both installed.
Notes :
a.This was tested on like versions of 32-bit and 64-bit drivers.
b.To viewthis procedure, Apple© QuickTime®should be installed.It can be downloaded for free at http://www.apple.com/quicktime/download/ .
SPECIAL NOTE : Solution contribution by Freddie Burnham, Production Print/SSD
Description
When using BOOTP Lite, what should be used to separate the MA C address information?
Solution
When entering the TCP/IP address, MAC hardware address, subnet mask (optional), and gateway (optional) into BOOTP Lite , separate the MAC
hardware address (Network address) information using colons (i.e, 00:e0:bb:05:31:d3), not spaces or hyphens. Other information is separated as normal
TCP/IP format (i.e, 198.169.2.12).
Note : The BOOTP Lite program is attached below and also can be downloaded via the Konica Minolta Download Selector. Access the Selector from SSD
Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Description
How to completely remove a printer driver in Microsoft® Windows 2000/XP/Vista™.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
26
IC-408 Miscellaneous
Solution
When removing a printer from the Printers folder, the printer driver file is not removed from the hard disk drive. This following describes a procedure to use if
a printer driver file is corrupted:
WINDOWS 2000
WARNING : If using Registry Editor incorrectly, serious problems may occur that will require reinstallation of the operating system. Microsoft®/KMBS cannot
guarantee that problems can be solved that result from using Registry Editor incorrectly. Use Registry Editor with extreme caution.
1. Remove the printer using the Printers folder in Microsoft® Windows 2000.
2. In Microsoft® Windows 2000, in Control Panel, double-click Administrative Tools, double-click Services, and then stop the S pooler service.
3. Run Registry Editor (Regedt32.exe) and go to the following subkey (note that this is all one path, which has been wrapped for readability):
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Print\Environments\Windows NT x86\Drivers\Version-3\
Note : Version-3 is Microsoft® Windows 2000, and is the name of the printer to be removed.
4. Notice the values on the right and write down the file names.
5. With the printer driver key selected, click Delete on the Edit menu.
6. Go to the following directory and delete the printer driver files noted in step 4:
%SystemRoot%\System32\Spool\Drivers\
Note :If unable to delete the f iles and folders in the above directory structure after stopping the spooler service because of an error message that the files
are in use (such as, Rasddui.dll), set the startup type for the Spooler service to Disabled, restart the computer, and then attempt to delete the files and folders
again. After deleting the files, restore the Spooler startup to Automatic.
7. In Microsoft® Windows 2000, in Control Panel, double-click Administrative Tools, double-click Services, and then start the Spooler service.
8. If reinstalling a printer, use the Printers folder.
9. Delete the %windir%\inf\oem?.inf file that is associated with the removed printer driver. This removes the printer from the printer selection list when adding
new printers.
Note : In addition to the steps listed above, it may be necessary to delete the printer's associated unidriver (Rasdd.dll, Pscript.dll, or Plotter.dll). If printing
has been initialized or if a process is using this file, it will be locked open and cannot be deleted. The fil e can be renamed or the system can be restarted to
free up the driver. Refer to the Printer.inf file to see which unidriver is used by a particular printer.
WINDOWS XP
Microsoft® Windows XP adds a user interface feature to delete driver files so the steps for Microsoft® Windows 2000 are no longer necessary. To delete
printer driver files in Microsoft® Windows XP:
1. Click Start, and then click Printers and Faxes.
2.
3. On
On the
the File menu,
Drivers tab,click
clickServer Properties.
the printer driver to be deleted, and then click Remove.
WINDOWS VISTA
Removal of a printer driver in Microsoft® Windows Vista™ is very similar to the procedure used for XP:
1. Open Printers by clicking the Start button, clicking Control Panel, clicking Hardware and Sound, and then clicking Printers.
2. Right-click the printer that you want to remove, and then click Delete. If you cannot delete the printer, right-click it again, click Run as administrator, and
then click Delete.
Remember, you cannot remove a printer if you have items in the print queue. If items are waiting to print when you try to remove a printer, Windows will wait
until printing is complete, and then remove the printer. If you have permission to manage documents on the printer, you can also cancel all print jobs and then
try to remove the printer again. For more information, see attached documentation concerning how to cancel printing and printer permissions. To viewthe
PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
Note : If you are prompted for an administrator password or confirmation, type the password or provide confirmation.
Solution
CAUSE: Failed ES-1000.
Profiler application.
devicetoverify if the Reboot.
problem Reinstall
is with thethe application.
computer USBReboot
port. Sagain, then aconnect
ometimes, theor
powered, ES-1000. If the
unpowered device
USB hub still is not
placed seen,
inline try another
between type of USB
thecomputer and ES-1000
will resolve this issue.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
27
IC-408 Miscellaneous
3. If, in step 2, no computer will recognize the ES-1000, then, more than likely, the ES-1000 itself is faulty. To verify this, or to fully test an ES-1000, download
the "ES-1000 Diagnostic Tool" from http://www.efi.com/support/download-software.asp . First,complete a quick registration, then select "EFI Software" link
and choose utility from the drop-down for download. There is a Macintosh® and a Windows® version. For more information on using this tool, go to
http://www.efi.com/support/production/fiery/measurement/color-profiler-suite/es-1000-instructions.asp .
4. Keep in mind that on a Macintosh® OSX machine, the ES-1000 is not supported when running in "Classic Mode". If wanting to use the ES-1000 while in an
OS9 application,boot into OS9 - do not go into Classic Mode while booted up into OSX.
5. An EFI print server must have support built into it for use with an E S-1000 ifintending to use it as a calibration device or use it for Spot-On within
ColorWise™ Pro Tools. Verify thatthe EFI print server model actually supports this. Most models sold prior to 2003, and even some current ones, did not
support the ES-1000 as a calibrator or with Spot-On. In some cases a patch or a newer version of ColorWise™ Pro Tools (version 38 or later - see attached)
will enable these applications for use with the ES-1000. Please contactthe OEM or EFI Tech Support to determine ifthe EFI print server can be "enabled" to
use the ES-1000 for Calibrator or Spot-On. If t he ES-1000 is being used on a Fiery® controller that has the FACI kit installed, the monitor provided with the
FACI kit contains a powered USB hub in its base. This should function the same as any hub that would be provided by EFI tech support. Plug the ES-1000
into the monitor hub and plug the monitor hub into the Fiery® USB port.
6. Ifhaving tried all the steps above, and ES -1000 is still not being detected, and,having determined that the device is bad by using t he ES-1000 Diagnostic
Tool, then the RMA return process should be initiated. Again, please contactthe OEM or EFI Tech Support.
Note : To open the attached file using WinZip®, WinZip® must be installed. WinZip® can be downloaded from the WinZip® website:
http://www.winzip.com/ddchomea.htm . The file can either be saved to disk or opened. It is recommended to download the ZIP and open from the local
computer to view.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
How to set up LDAP on a Fiery® IC-303, Fiery® IC-305or Fiery® IC-408.
Solution
Please see the attachments forcomplete setup procedures. To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free
from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
Note :Fiery® IC-303 and Fiery® IC-305use the same system software.
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Description
Printgroove-supported printers.
Solution
Printgroove-supported Printers
Konica Minolta:
bizhub PRO 1050/1050P Embedded Full
bizhub PRO 920 IC-203 Full
bizhub PRO C500/8050 IP-901/IC-302/IC-405 Limited
bizhub PRO C500 IC-301 Limited
bizhub PRO C6500/6500P IC-303/IC-305/IC-408 Limited
bizhub C650 IC-409 Limited
7085 IP-602/IP-602M Limited
Xerox©:
DocuTech 6100 series DocuSP 4.x Limited
Note : The bizhub C650 IC-409 and Xerox© DocuTech 6100 series DocuSP 4.x are now supported with PrintgroovePOD SERVE/GUIDE/QUEUE version
1.3.
Description
How to configure LDAP access on a Lotus® Notes R5 or R6 server.
Solution
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
28
IC-408 Miscellaneous
Description
How to properly remove Command WorkStation™ from a Macintosh®.
Solution
Please perform the step-by-step procedures mentioned in the attached document.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez and Mark D'Attilio, Production Print/SSD
Description
Booklet Making (saddle-stitch) on Macintosh® 10.4.x or Microsoft® Windows XP.
Solution
Please see the attached documentationfor complete details.
To viewa PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez and David Aekus, Production Print/SSD
Description
How to enable SMB (File Sharing) from a Macintosh® OSX 10.2, 10.3 and 10.4.8, or 10.5.
Solution
Please see the attached documentsexplaining how to enable SMB (File Sharing) from a
Macintosh® OSX 10.2, 10.3 and 10.4.8, or 10.5. To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the
Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Ed Bellone/Cesar Jimenez/Ian Lynch, Production Print/SSD
Description
Features of version 1.1 system code for the Fiery® IC-408 controller.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
29
IC-408 Miscellaneous
Solution
The following are some key features enabled by version 1.1 on the IC-408:
Sample print
o Enables operator to check image quality mid-run
o Send sample print (either random or based on pre-determined interval) to sub
tray for image quality inspection
Although this IC-408 supports both the bizhub PRO C6500 and bizhub PRO C5500, the above configurations are not supported on the bizhub PRO C5500.
The IC-408 does not support the bizhub PRO C6500P.
New IC-408 image controllers with serial numbers of A0360Y0004012 or higher will be shipped loaded with the version 1.1 system code.
For current IC-408 installations the IC-408 system code must be updated to new version 1.1 via one of the following methods:
o Download the version 1.1 files (> 5GB) from the Konica Minolta Download
Selector.
o Order the version 1.1 DVD (p/n 45072657) fromSSD.
Description
Memory upgrade option for IC-408 controller.
Solution
The IC-408 comes standard with 512MB of RAM. An additional 512MB memory upgrade is available (Item #7640002934). The 512MB memory option
enables the IC-408 to be configured with a maximum of 1GB total memory.
Note : When installing the optional memory upgrade, the attached IC408_memupgrade.exe patch must be installed on version 1.0A or earlier system code.
On version 1.1 and higher no patch is needed for expanded memory. The patch file is also available via the Konica Minolta Download Selector. Access the
Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
How to uninstall EFI Command WorkStation™ from a Macintosh® OS 10.x system.
Solution
To uninstall EFI Command WorkStation™ from a Macintosh® OS 10.x system:
IMPORTANT :Be sure to delete only the f iles listed. Other deletions or changes can lead to system problems. Ifany other EFI utilities areinstalled, skip steps
4 and 5.
1. Double-click the hard disk drive i con onthe desktop.
2. Delete the /Applications/Fiery/CWS Macintosh Edition folder.
3. In the /Applications/Fiery folder, delete the following if they were installed with Command WorkStation™, Macintosh® Edition:
h10.framework
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
30
IC-408 Miscellaneous
haddress.framework
harmony.framework
hbalance.framework
hbasic.framework
hbridge.framework
hclick.framework
hcore.framework
hcorp.framework
hcsp.framework
hctp.framework
hefi_color.framework
hefi.framework
hefim.framework
hextra.framework
hgasetup.framework
hglobobj.framework
hlicense.framework
hpageman.framework
hprintme.framework
hpserver.framework
hscan.framework
5. Delete the file i1C.framework in the /Library/Frameworks folder.
6. In the /Users/ /Library/Preferences folder, wherethe name is of the user currently logged in to the Macintosh® OS X computer, delete the files and folder
starting with the string “CWS”.
7. In the ~/Users/ /Library/Preferences folder, delete the following files (if ColorWise™ Pro Tools and ImageViewer were installed with Command
WorkStation™, Macintosh® Edition):
CWPT Preferences
Description
Information concerning the bizhub PRO C5500/C6500/IC-408/FS-520 configuration.
Solution
The bizhub PRO C5500/C6500/IC-408/FS-520 configuration is now available. With IC-408 version 1.0, the following patches are required 1-PYRSX and
1-UY7PG (IC-408 versions 1.0a and 1.1 do not require the patches).
Notes :
1.See attached configuration sheet. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web
site at: http://www.adobe.com/products/acrobat/readstep2.html .
2.The IC-303 and IC-305is not compatible with the FS-520.
3.The latest version firmware or system software is available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS
Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Clinton Marquardt, ESS /SSD and Ed Bellone, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
31
IC-408 Miscellaneous
Description
How to perform a calibration with ColorCal™ or ES-1000.
Solution
Steps to reproduce using ColorCal™ :
1. Run ColorWise Pro Tools® and login to the Fiery®; then click Calibrator.
2. Select the following:
a. Measurement Method = ColorCal™
b. Print Settings => Calibration Set => Media = Normal
3. Print Measurement Page. Place on the MFP glass with grayscale strip (Kodak® Gray Scale - p/n 10012662).
4.
5. Click
Select"Measure".
"Yes" for Scanner Calibration and follow the instructions.
6. After successful scanner calibration, click "Measure" and follow the instructions to completion.
7. After successful measurement process, print comparison page.
8. Click "Apply".
9. Click Done to close Calibration.
Note :See the attached MPEG file (CalScan.MPG), for ColorCal™ procedure.
Description
What is the user name and password for Remote Desktop?
Solution
The user name is 'Administrator' and the password is 'Fiery.1'. Both the user name and password are case sensitive.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Solution
The latest 64-bit printer drivers are available via the Konica Minolta Download Selector. Access the Selector from theKMBS public site (
http://www.kmbs.konicaminolta.us ) Support & Drivers tab or from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers,
Firmware and more'.
Description
Fiery® Microsoft® Windows Vista™ 32-bit and 64-bit utilities availability.
Solution
EFI® has released utilities that are compatible with 32-bit and 64-bit versions of Microsoft® Windows XP/2003/Vista™. They are also compatible with
Microsoft®Windows 2000.
The utility CD is available for downloadthrough the Konica Minolta download site in ISO format. The filename is Fiery_Utilities_Vista32_64.iso
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
32
IC-408 Miscellaneous
Note for Microsoft® Windows XP Users: Windows XP Service Pack 2 is required to install these utility applications on Windows XP operating systems.
A security issue has been identified in Microsoft® XML Core Services (MSXML) that could allow an attacker to compromisea Windows-based system and
gain control over it. These utilities have been updated to be compatible with this change. Details of the security changes are available at:
http://www.microsoft.com/downloads/details.aspx?FamilyId=dea6a48f-fb00-43f3-a374-3220f9759c2d&displaylang=en
This updated utility package is available for previously-shipped products using Fiery® code
bases System 5/5e through System 8/8e.
The following is a list of the applications in this package:
Impose 2.7
Compose 2.0
Windows 2000
WebTools: Microsoft® has 32-bit and 64-bit Internet Explorer applications packaged into their 64-bit operating systems. For 64-bit environments, WebTools is
only supported using 32-bit Internet Explorer. It will not function using 64-bit Internet Explorer.
Impose and Compose: Impose and Compose: For Impose 2.7, full Vista™ compatibility requires Acrobat® 8.1 and Pitstop 7.2. The user will only experience
the same level of functionality based on the available features of the Fiery®.
E-mail Port Monitor: EFI® will not provide a Vista™ compliant E-mail Port Monitor
application. This application will not operate under Windows Vista™.
SPECIAL NOTE : Solution contribution by Bill Ehmke, ESS/SSD
Description
System code version 1.0a for IC-408 Fiery® controller.
Solution
System code version 1.0a for IC-408 Fiery® controller is available for download via the Konica Minolta Download Selector. Access the Selector from SSD
Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.Please refer to the attached Release Notes and Installation
Instructionsfor additional detail.
To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
IMPORTANT WARNING : When running the installation program for version 1.0a system code, which copies files onto the computer being used for
installation, it is extremely important thatit isinstalled into a folder on the hard drive. DO NOT INSTALL IT TO THE ROOT of the C:\ drive.
If the code is loaded onto the root of the hard drive, all other data and programs on the drive will be destroyed.
IMPORTANT :Pleaseshare this crucial informationwith all technicians who might need to install System Code 1.0a on the IC-408.
SPECIAL NOTE : Solution contribution by Tony Pizzoferrato, ESS/S SD
Description
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
33
IC-408 Miscellaneous
Why Command WorkStation™ does not show t he correct memory in the Fiery® controller.
Solution
Fiery® configuration sheet will show the correct memory size in the controller.
Note : IC-303 will need to have system code version 1.1 installed. Command WorkStation™ will show approximately half of the available memory in the
controller.
Note : The latest version firmware or system software is available via the Konica Minolta Download Selector. Access the Selector from SS D Web Support
(CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Mike McCarthy, Production Print/SSD
Description
Burning ISO images.
Solution
Please perform the procedures mentioned in the attached documentation. To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be
downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Description
Why the controller does not boot fully after updating to version 1.1 system code. Controller will indicate "FF" for an extended amount of time after initial reboot.
Solution
This is correct operation. After initial reboot the controller will take 60 minutes to finish writing new system code and complete boot. Af ter this amount of time
the controller will indicate "00" onthe LED and controller will be recognized by main body.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
How to install system code version 1.1 on the IC-408 through the Ethernet port or USB flash drive.
Solution
ETHERNET LOAD
The installation program must be run directly from the DVD;
1. Disconnect cables from Fiery® and power it down. Power downthe MFPusing sub-switch.
2. Power on PC and disable wireless port, firewall, and FTP and TFTP services
3. Enable DHCP on PC.
4. If Auto run does not start the install programon the DVD when inserted, Double-click on Fiery® Installer.exe.
5. Flip both DIPswitches (one inch away from LED display on Fiery® - sometimes covered by gray tape).
6. Select language, approve license screen and Ethernet connection screen.
7. TurnON the Fiery® power switch and wait 15 seconds or so until "FF" is seen on t he Fiery® LED (green switch light must be ON). Within 2-3 minutes "1 of
11" will show on installer screen.
8. This will take about 25 minutes.
9. Once "11 of 11" is done, with status bar not moving and "0KB" visible, click "Finish".
10. Ignore verbiage in installer, power down the Fiery® using the AC switch, reset DIPswitches to srcinal, then power down the MFP using the main
sub-switch.
11. Reconnect normal cables, power up the MFP, then the Fiery® AC switch making sure green soft-switch light goes ON.
12. At this point it can take the Fiery® up to 60 minutes to complete self-install. When the Fiery® is done the "Controller" button on the MFP LCD is active
and "00" is seen on the Fiery® LED.
13. Set up the Fiery® partially through the MFP interface, or via Web Configure (more settings).
c. DIPswitches
d. PowerON thedo NOT have
Fiery® to be changed
AC switch. for this
If green light doesload
notmethod.
come on, push soft-switch until it does. Shortly, observe LED on flash drive itself sporadically
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
34
IC-408 Miscellaneous
flashes.
e. When done (about 10 minutes), LED on Fiery® shows "FF" and stays there; flash drive ceases blinking.
f. PowerOFF Fiery® AC switch, wait at least 30 seconds, remove flash drive andreconnect cables.
g. Power ON the MFP sub-switch, then the Fiery®,watching to ensure green light comes on.
h. The Fiery® must self-configure for 45 minutes. Unfortunately, there is nothing, other than very intermittent Fiery® LED activity to show if anything is really
happening. Be patient and wait 45 minutes.
i. IMPORTANT - Power down the Fiery® andcompletely power down the MFP. Power up the MFP, wait for normal MFP screen to appear and then bring
up the Fiery®, making sure green soft-switch light is ON. Within 3-5 minutes "Controller" button on LCD should be active.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD
Description
How to load a 32-bit driver on a 64-bit operating system.
Solution
Please follow this step-by-step procedure and refer to the attached video.
1. Load the 64-bit driver on the server and share it out.
2. Load a 32-bit driver on a workstation locally.
3. From the workstation perform the Run command to connect to the server (example: \\11.11.5.33) and press enter. This should bring up t he server.
4.Navigate to the previously shared out printer on the server.
5. Right-click on the shared out printer and select properties.
6. Select the sharing tab and then click on the Additional Drivers button.
7. Select or check-off the 32-bit driver to be added to the 64-bit system.
8. Select OK and then browse to the folder that houses the 32-bit driver to be installed and select OK. The Additional Drivers window should now have the
32-bitand 64-bit checked off.
9. Check the Additional Drivers of the Server to make sure that the 32-bit has been pushed up (right-click on the shared out printer of the server
=>Properties =>Sharing Tab =>Additional Drivers).
Notes :
Description
How to set up FTP Publishing Services on a Microsoft® Vista™ workstation.
Solution
Please follow the step-by-step procedures as shown in the attacheddocument.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Description
How to install a printer using LPR (IP Printing) under Macintosh® OS9.
Solution
Please perform the procedures mentioned in the attached document.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Mark D'Atti lio, Production Print/SSD
Description
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
35
IC-408 Miscellaneous
Solution
The bizhub PRO C6500/IC-408 is only supported in MicroPress® 7.5.0.1 and later.
Note : Firmware version 30 for the bizhub PRO C6500, IC-408 version 1.1 code and the three required patches are required for MicroPress® support. The
latest version firmware or system software is available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS E xpert
Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
IMPORTANT : The three patchesmust be loaded in order.
Patch 1 - 015k.ps
Patch 2 - 015n.ps
Patch 3 - 015o.ps
These patches (Micropress-patch.zip) arealso available via the Konica Minolta Download Selector. Please seeattached patch files and associated
documentation
be downloaded (foraccessibility
for free from theincase theweb
Adobe® Download
site at:Selector cannot be accessed). To viewthe PDF, Adobe Reader®
http://www.adobe.com/products/acrobat/readstep2.html . must be installed. Adobe Reader® can
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
How to insert a blank page after each set when printing multiple sets of a document.
Solution
To insert a blank page after each set when printing multiple sets of a document perform the following:
1. Select the Media tab in the driver.
2. Under Mixed Media select Define.
3. Select Insert Blank.
4. Insert Blank is displayed; select AFTER.
5. Select the radio button that indicates Last Page.
6. Select Insert Blank. Make any needed changes for the paper tray such as the t ray to be used for the insert and any paper weight definitions and press
Insert and then Close.
7. The document is ready for printing.
SPECIAL NOTE : Solution contribution by Mark D'Attil io, Production Print/SSD
Description
How to set a Fiery® device to use the output profile of a different Fiery® device.
Solution
IMPORTANT :The Graphic Arts Package must be installed to accomplish this.
To usethe output profile of a different Fiery® device:
1. Open Command WorkStation™.
2. Log into the Fiery®having the output profileto emulate.
3. Select "Server".
4. Select "Manage Color". "ColorWise Pro Tools" interface opens.
5. Select "Profile Manager". In the "Output list" (right side, third section from the top) click the small icon that resembles a target to organize Output list and
select desired paper setting profile.
6. When profile selected, a green arrow will appear to the left of selection. Click green arrow and theSave As window opens.
7. Select name forprofile (*using IC-405 as example* suggest changing profile name from"Fiery 50C-KM Plain N v4" to "IC-405 Plain" for ease of customer
use).
8. After profile has been saved select "Server".
9. Select"Log In/Log Out". Login window opens.
10. Log into Fiery®to which the device profileis to beadded.
11. Select "Server".
12. Select "Manage Color". "ColorWise Pro Tools"window opens again.
13. Select "Profile Manager". Locate profilethat was saved from list on left side of window and click profile. When profile is selected,green arrows appear
pointing to "Simulation" section and "Ouput" section.
14. Click arrow pointing to "Output" section and pop-up appears.
15. Click OK. Another pop-up appears that indicates "Download "Succesful".
16. Click OK. Third pop-up opens. Checkbox next to "Appear in Driver as".
17. Select "Output 1 - 10". E ach output can be used only once. Ifattempting tosaveanotherprofile as a previously selected Output, it will override the previous
profile.
18. Click "Apply".
19. Click "Done".
20. Close "ColorWise Pro Tools".
Now the output profile is available in the expert color settings of t he devices print driver GUI.
To access from application (may vary depending on Fiery® version) select File=> Print=> Properties=> Color=> Expert Settings. Under "Ouput
Profile" select "Use Output Profile". Select desired profile from drop down menu.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
36
IC-408 Miscellaneous
Description
Is the ES-1000 compatible for use with the IC-301, IC-303, CREO© (IC-304), IC-305,IC-408 and the bizhub PRO C6500?
Solution
The ES-1000 spectrophotometer (Item #7640004314)is compatible for use with the CREO© controller (with version 1.0SP2 or higher) as well as the IC-303,
IC-305 and IC-408 controllers and the bizhub PRO C6500.
The ES-1000 spectrometer isNOT compatible with the IC-301.
SPECIAL NOTE : Solution contribution by Ed Bellone/Greg Lantowski/Ian Lynch, Production Print/SSD
Description
How to enable/disable the DETAIL CHECK button on the MFP display, and force printed jobs to printmessages such as "Please load designated Paper in
Tray”, “Incorrect paper size”, “Incorrect paper weight”, “To check details, touch [Detail Check]" is indicated”.
Solution
To enable/disable the DETAIL CHECK button on t heMFP display (this is done on the controller),perform the following:
1. Browse to the Fiery® controllers viathe TCP/IP address.
2. Launch the Fiery® Web Tools and log in under Administrator, Fiery.1.
3. LaunchConfigure.
4. Select Server.
5. Select Jobs and enable/disable the JOB MISMATCH ACTION IS DETECTED.
6.Select Apply followed by a reboot of the controller.
SPECIAL NOTE : Solution contribution by Freddie Burnham and Ed Bellone, Production Print/SSD
Description
SMTP error 554.
Solution
CAUSE: The mail servers are set to P OP before SMTP as a security measure to prevent SPAM. The mail server collectsthe TCP/IP address during
authenticationwith the POP server, and then permits SMTP relaying from that TCP/IP address for a short period of time.
This means thatincoming mail MUST be checkedbeforemail is allowed to be sent. Ifsettingan E-mail client (like Microsoft® Outlook) to checkmail
regularly,outgoing mail may sit inthe Outbox until the incoming mail is checked again.
Ifonly checking mail wheninitially openingthe E-mail client,a Send/Receive will need to be forced beforethe outgoing mail can be sent.
IfE-mail is not checked within 30 minutes,an "Error 554: Relay Access Denied" error may be received.
Description
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
37
IC-408 Miscellaneous
Solution
To find the MAC address of a specific device in a Microsoft® Windows environment, such as a main body internal NIC, access the command prompt,PING
the TCP/IP address of the device and then perform the command, arp –a .
The attached procedures are for Microsoft® Windows 98/NT/2000/2003/XP, DOS/Microsoft® Windows 3.11/Microsoft® Windows for Workgroups, Microsoft®
Windows Vista™ and Macintosh® OS X. To viewa PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe®
web site at: http://www.adobe.com/products/acrobat/readstep2.html .
Note : Also attached is the Technitium MAC A ddress Changer© freeware program. This software is not supported by Konica Minolta and is t o be used at
your own risk.
To open the ZIP file, WinZip® should be installed. WinZip® can be downloaded from the WinZip® website: http://www.winzip.com/ddchomea.htm . The file
can either be saved to disk or opened. It is recommended to download the ZIP and open from the local computer to view or run.
SPECIAL NOTE : Solution contribution by Cesar Jimenez and Freddie Burnham, Production Print/SSD
Description
How to change the Page Size in Adobe® InDesign® in Macintosh® OSX 10.5.
Solution
To change the Page Size in Adobe® InDesign® in Macintosh® OSX 10.5:
1. With the document open, select File.
2. Select Print.
3. On the General tab select the printer from the list.
4. On the Setup tab select the desired page size.
5. Select Print to print the job.
SPECIAL NOTE : Solution contribution by Gregg Gallant and Mark D'Attilio, Production Print/SSD
Description
How to change the Page Size in Adobe® Acrobat® in Macintosh® OSX 10.5.
Solution
To change the Page Size in Adobe® Acrobat® in Macintosh® OSX 10.5:
1. With the document open, select File.
2. Select Page Setup.
3. Format For: Select the printer from t he list.
4.Page Size:Select the desired page size.
5. SelectOK.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Description
How to determine if an ES-1000 Spectrophotometer is faulty.
Solution
To determine if an ES-1000 Spectrophotometer is faulty, please read the following instructions to use EFI's diagnostic tool:
1. Go to http://www.efi.com/support/download-software.asp , andlogin to download the most recent version of the diagnostic tool.
2. Register and provide the ES-1000 serial number located on the bottom of the unit.
3. Select the "Software Update" link.
4. Look for Macintosh® and PC diagnostic tools are located under "Eye-One Diagnostics" (the simple installation takes only minutes to complete).
5. Attach the ES-1000 to the USB port and open the diagnostic tool.As soon as the window opens, there will be a message indicating whether or not the
device is attached. The note should say "Device found" if the ES-1000 is attached correctly.If not, the message will indicate that the device is not
communicating at a basic level.
6. Run the diagnostic and carefully follow the directions.
7. Scroll through the on-screen report for pass or fail results.In the results, the device serial number should matchthe ES-1000 sticker located at the bottom of
the device. If not, consider this process a failure. Any other t ypes of failures should be listed clearly.
8. Look for the phrase "Eye-One pro test passed" to see if the test was successful.Ifthis phrase is not indicated, the diagnostic failed.
9. Attempt
10. Attemptanother
anotherdiagnostic
diagnosticusing
with athe samecomputer
second computerififthe
thediagnostic
diagnosticfails
failed t he first time.
again.This second diagnostic is to eliminate the possibility that the first computer
is the problem.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
38
IC-408 Miscellaneous
Description
Does the Fiery® support scan to E-mail to an offsite E-mail server?
Solution
If properly configured, the Fiery® will scan to an offsite E-mail server (including Yahoo!®, Hotmail®, Cox©, Comcast© ). The Fiery® supports POP3, IMAP
and SMTP protocols.
Description
Part number for IC-408 system 2.0 DVD disc set.
Solution
Version 2.0 DVD (p/n 45079926).
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
Configuration and specification information.
Solution
See attachmentsfor information which includes:
Configuration Sheets
bizhub PRO C6501/C6501P/C5501
1. How to Build a System for the bizhub PRO C6501/C6501P/C5501 (from start to finish)
2. Accessory Options for bizhub PRO C6501/C6501P/C5501. Options include:
DOCUMENT HANDLING
DF-609 Reversing Automatic Document Feeder - Not available with the bizhub PRO C6501P
OC-506 Original Cover - Not available with the bizhub PRO C6501P
PAPER SUPPLY
HT-503 Dehumidifier Heater for LU-202
HT-504 Dehumidifier Heater for PF-602 - bizhub PRO C6501 only
LU-202 Large Capacity Tray 2500 sheet capacity
PF-602 Paper Feed Unit 6000 sheet capacity (2x3000) - bizhub PRO C6501 only
OUTPUT
FD-503 Multi-Folding Unit
FS-520 Stapler Finisher
FS-521 100-Sheet Stapling Finisher
FS-607 Booklet Finisher
LS-505 Large Capacity Stacker 5000-sheet capacity
OT-502 Output Tray - bizhub PRO C5501 only
PB-502 Perfect Binder Unit
PI-502 Post Inserter for FS-607
PK-512 2/3-Hole Punch Kit for FS-607
RU-504 Relay Unit (with power supply)
SD-506 Saddle Stitch Finisher
HDD
HD-506
CONTROLLER
IC-304/Plus External Creo Image Controller
IC-305 External Fiery Image Controller
IC-408 Embedded Fiery Image Controller -Not available with the bizhub PRO C6501P
12GB
GB1GB
2GBMemory
MemoryUpgrade
Upgradefor
forIC-305
IC-305
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
39
IC-408 Miscellaneous
PAPER SUPPLY
HT-503 Dehumidifier Heater for LU-202
HT-504 Dehumidifier Heater for PF-602
LU-202 Large Capacity Tray 2500 sheet capacity
PF-602 Paper Feed Unit 6000 sheet capacity (2x3000)
OUTPUT
FD-503 Multi-Folding Unit
FS-520 Stapler Finisher
FS-521 100-Sheet Stapling Finisher
FS-607 Booklet Finisher
LS-505 Large Capacity Stacker 5000-sheet capacity
PB-502 Perfect Binder Unit
PI-502 Post Inserter for FS-607
PK-512 2/3-Hole Punch Kit for FS-607
RU-504 Relay Unit (with power supply)
SD-506 Saddle Stitch Finisher
HDD
HD-506 4 x 40GB Hard Drives
CONTROLLER
IC-304/Plus External Creo Image Controller
IC-305 External Fiery Image Controller
1 GB 1GB Memory Upgrade for IC-305
2 GB 2GB Memory Upgrade for IC-305
Specification Sheets
1. bizhub PRO C6501 Specification sheet
2. bizhub PRO C5501 Specification & Installation Guide topicsinclude:
Duty Cycle
Space Requirements
Environmental Requirements
Electrical Requirements
Component Considerations
Paper Trays/Exit Tray Capacity
Paper Size
ADF Originals
IC-408 Embedded Controller Specifications
IC-304 Plus Print Controller Specifications
IC-305 External Controller Specifications
Security Strengthen Mode
Paper Considerations
Paper Weight Conversion Chart
3. bizhub PRO C65hc Specification sheet
4. bizhub PRO C65hc Specification & Installation Guide topicsinclude:
Duty Cycle
Space Requirements
Environmental Requirements
Electrical Requirements
Component Considerations
Paper Weight
Paper Trays/Exit Tray Capacity
Paper Size
ADF Originals
IC-304 Plus Print Controller Specifications
IC-305 External Controller Specifications
Security Strengthen Mode
Paper Considerations
Paper Weight Conversion Chart
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
40
IC-408 Miscellaneous
http://www.winzip.com/ddchomea.htm . The file can either be saved to disk or opened. It is recommended to download the ZIP and open from the local
computer to view.
b.To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
Description
How to attach an Adobe® InDesign®file to a ticket if a sample copy is requested.
Solution
To attachan Adobe® InDesign®file to a ticket, use thisprocedure:
1. In the InDesign® document, select File.
2. Select Package.
3. Fill out the Information t ab with ticket number and anything relevant to the ticket.
4. Select Continue.
5. Create a Folder name (use the ticket number).
6. Below the folder name check off the f ollowing: Copy Fonts, Copy Links, Graphics Updating, and Graphic Link.
7. Click Package.
8. Zip the resulting folder and attach it to the ticket.
SPECIAL NOTE : Solution contribution by Craig Blyther, A SG/SSD
Description
Solution
The default ports are 25 for outgoing and 110 for incoming. To change ports:
1. Browse to the Fiery® TCP/IP address.
2. Select Web Tools.
3. Select Configure tab.
4. Select Launch Configure.
5. A new window will open, input the Administrator password when prompted.
6. From settings list on left side (gray background), select Network.
7. In Network settings options, select Services.
8. In Services settings options, select either E-mail or Print via E -mail.
9. In E-mail settings options on right side of window (white background) select E-mail Setup.
10. A new window will open with E-mail Server settings.
11. Change port numbers as needed.
12. Select Save, window closes.
13. In srcinal Configure window, select Reboot from left side menu (gray background) to apply setting changes.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
How to set up Scan to SMB on Microsoft® Windows 2008 Server.
Solution
Please see the attached video for the procedure. The video should be played on Microsoft® Windows Media Player version 9 or later. The latest Media
Player can be downloaded at: http://www.microsoft.com/windows/windowsmedia/default.mspx .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Description
How to archive a file from a MicroPress® 7/7.5/8 system.
Solution
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
41
IC-408 Miscellaneous
Description
How to set up a TCP/IP address Relay Configuration on a Microsoft® Windows 2003 Exchange Server. Please see the attached files for instruction.
Solution
To set up a TCP/I P Address Relay Configuration on a Microsoft® Windows 2003 Exchange Server, perform the following:
1. Login to the Microsoft® Windows 2003 Exchange Server.
2. Click on All Programs ? Microsoft Exchange ? System Manager .
3. Click on Servers ? select server.
4. Click on Protocols ? SMTP .
5. Right Click on Default SMTP Virtual Server and click on Properties .
6. Click on the Access Tab, then under Relay Restrictions click on Relay .
7. Under Single Computer, add the TCP/IP address of the printer and click OK .
8. A Granted Key with the TCP/IP address of the printer will be indicated; click OK .
9. Now the server is set up to give t he MFP device E-mail Relay Access.
Note :Please see the attached document as a quick reference. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for
free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by John Miller, Workgroup/SSD
Description
PLEASE REPLACE TONER FILTER message and unable to perform the copier auto calibration function from the copier, or from print controller. The
Calibration Test Page is never output.
Solution
CAUSE: The dust-proof filter/2 (rear)is activated on the copier control panel.
SOLUTION: To clear the message on the copier and to allow the A uto Calibration to be performed, follow these steps:
1. Enter Service mode.
2. Select [COUNTER/DATA].
3. Select [PARTS COUNTER].
4. Select [COUNT OF SPECIAL PARTS].
5. Using the down arrow, scroll down until Dust-proof filter/2 (rear) is highlighted.
6. Select [COUNT RESET].
7. Exit the Service mode.
SPECIAL NOTE : Solution contribution by David Aekus, Production Print/SSD
Description
Additional 512MB memory is not listed in the configuration pages with system code 1.0a.
Solution
CAUSE: Required memory patch has not been installed onto the IC-408 controller.
SOLUTION: Install patch 1-UT8R4 to the IC-408 with system code 1.0a to support the 512MB memory upgraded kit.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
42
IC-408 Miscellaneous
With the patch installed, total memory listed on the configuration page will be 1008MB.
Notes :
1. Please ensure that the additional memory is installed when the patch is i nstalled or the IC-408 controller will not fully boot up.
2. The IC-408 system code will need to be reloaded if t he additional 512MB of memory is to be removed.
3. Please be aware that only the configuration page will show the total amount of memory installed. RAM memory installed on the controller is partitioned on
the controller between the OS and the System code. Memory listed in Command WorkStation™ will be 551MB total and memory listed under the Microsoft®
Windows XP operating system will be 448MB total.
4. The memory patch 1-UT8R4 is available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by
clicking on 'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Tony Pizzoferrato, ESS/S SD
Solution
CAUSE:This is correct operation. Job flow is designed to process and output smallest jobs first in order to optimize processing speed and memory allocation.
SOLUTION:At this time there is no workaround. Please fill out attachedProduct Change Request,save file,create a problem ticket via web submission or call
into the SSD Hotline andattach completed Product Change Request to the ticket for escalation to Marketing for review.
Note : To view the document(s), Microsoft® Word® or Word® Viewer must be installed. Word® Viewer 2003 (11.7MB) can be obtained free from
Microsoft® at the following URL;
http://www.microsoft.com/downloads/details.aspx?DisplayLang=en&FamilyID=95e24c87-8732-48d5-8689-ab826e7b8fdf .
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
Solution
ID TAUS0700116EN* Solution
Usage
Description
What is the standard password for the Fiery® controller?
Solution
The default password is Fiery.1 .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0700308EN* Solution
Usage
Description
When installing patches on the controller using the Fiery® Downloader, what is the User Name, Password and Hostname?
Solution
User = admin
Password = Fiery.1 (default password)
Hostname = Fiery® TCP/IP address
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0700914EN* Solution
Usage
Description
How to Secure Print.
Solution
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
43
IC-408 Miscellaneous
Solution
ID TAUS0701008EN* Solution
Usage
Description
How to retreive a scan to HDD using a web browser (Fiery® WebScan).
Solution
To retrieve a scan to HDD using a web browser (Fiery® WebScan)perform the following:
1. Access the home page of the controller.
2. Select Webtools.
3. Select the Docs tab in the newly opened window.
4. Either log into the desired mailbox or use the guest box depending on where the scan was scanned to.
5. Select the box by the desired file.
6. Select the download icon above the list and follow the prompts.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD
Solution
ID TAUS0702585EN* Solution
Usage
Description
How to bypass an external key counter for printing.
Solution
To bypass an external key counter for printing, perform the following:
1. Enter Service Mode.
2. Press Stop and then 9.
3. Press Management Function.
4. Press NOT OBJECT for the printer.
SPECIAL NOTE : Solution contribution by Ed Bellone/Jim Behrends/Ian Lynch, Production Print/SSD
Solution
ID TAUS0702889EN* Solution
Usage
Description
Printing to a printer on a Microsoft® Windows XP PC from a Macintosh® OS version 10.3.
Solution
Please perfrom the step-by-step procedures mentioned in the attached PDF.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez and Mark D'Attilio, Production Print/SSD
Solution
ID TAUS0703119EN* Solution
Usage
Description
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
44
IC-408 Miscellaneous
What options are supported with MicroPress® 7.5.0.1 and the bizhub PRO C6500/IC-408?
Solution
The following options are supported with MicroPress® 7.5.0.1 and the bizhub PRO C6500/IC-408:
FS-607
PK-512 Booklet Finisher
(US) Punch Kit
PK-512 (EU) Punch Kit
PK-513 Punch Kit
PI-502 Post Inserter
SPECIAL NOTE : Solution contribution by Bob Felch, ESS/SSD
Solution
ID TAUS0703487EN* Solution
Usage
Description
How to archive a Fiery® print job for emailing or attachment to a help desk ticket.
Solution
Follow these procedures to archive a file correctly for submissionto SSD.
Ensure that the job to be archived has been rasterized and is in the active jobs/held queue. If the job has not been rasterized, it will not archive correctly.
Highlight the job and right click on it. Select "Archive" from the drop down menu. Check the "Archive Rasters" box; thenchoose a destination for the archive
and select OK. The archive will consist of multiple files in a folder that has the same name as the job name.
To make the files portable, compress them into a zip f ormat using WinZip® or another archive application.
Select the folder that contains thearchives and zip it with all of its contents. This will produce a single portable file that can be attached to a help desk ticket,
e-mailed, or transferred via FTP.
Solution
ID TAUS0703494EN* Solution
Usage
Description
Is the IC-408 controller supported with the bizhub PRO C6500P?
Solution
The IC-408 is not supported with the bizhub PRO C6500P.
SPECIAL NOTE :Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0703756EN* Solution
Usage
Description
General security questions regarding Fiery® controllers.
Solution
Please see the attached Fiery® Security White Paper.The document answers many general questions andsome of the topics included concern:
network encryption
anti-virus strategies
port security
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Gabe Smith, ESS/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
45
IC-408 Miscellaneous
Solution
ID TAUS0703818EN* Solution
Usage
Description
How to automatically convert A4\A3 paper to U.S. paper sizes.
Solution
To automatically convert A4\A3 paper to U.S. paper sizes perform the following:
1. Enter Fiery® Setup.
2. Enter PostScript Setup.
3. Change Convert Paper Sizes to A4/A3 => Letter/11x17.
4. Save changes and reboot the Fiery® controller.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0800031EN* Solution
Usage
Description
Does the IC-408 support the attachment of a PB-501?
Solution
The IC-408 does not support the attachment of a PB-501 and there are no plans to support this configuration.Please refer to attached documentation for
details.
To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Ian Lynch and Ed Bellone, Production Print/SSD
Solution
ID TAUS0800073EN* Solution
Usage
Description
Solution
ID TAUS0800699EN* Solution
Usage
Description
Fiery® X3eTY 50_45C-KM /IC-409/ IC-408POST code.
Solution
The following is the POST (Power On Self Test) code list for Fiery® X3eTY 50_45C-KM/IC-409(information from EFI).
Code
Description
CF
C0
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
46
IC-408 Miscellaneous
C1
Detect memory
-Auto-detection of DRAM size, type and ECC.
-Auto-detection of L2 cache (socket 7 or below)
C3
C5
Call chipset hook to copy BIOS back to E000 & F000 shadow RAM.
01
02
Reserved
03
04
Reserved
05
06
Reserved
07
08
1. Test special keyboard controller for Winbond 977 series Super I/O chips.
2. Enable keyboard interface.
09
Reserved
0A
0B
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
47
IC-408 Miscellaneous
Reserved
0C
Reserved
0D
Reserved
0E
Test F000h segment shadow to see whether it is R/W-able or not. If test fails, keep beeping the speaker.
0F
Reserved
10
Auto detect flash type to load appropriate flash R/W codes into the run time area in F000 for ESCD & DMI support.
Code
Description
11
Reserved
12
Use walking 1’s algorithm to check out interface in CMOS circuitry. Also set real-time clock power status, and then check for override.
13
Reserved
14
Program chipset default values into chipset. Chipset default values are MODBINable by OEM customers.
15
Reserved
16
17
Reserved
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
48
IC-408 Miscellaneous
18
Detect CPU information including brand, SMI type (Cyrix or Intel) and CPU level (586 or 686).
19
Reserved
1A
Reserved
1B
Initial interrupts vector table. If no special specified, all H/W interrupts are directed to SPURIOUS_INT_HDLR & S/W interrupts to
SPURIOUS_soft_HDLR.
1C
Reserved
1D
1E
Reserved
1F
20
Reserved
21
22
Reserved
23
24
Prepare BIOS resource map for PCI & PnP use. If ESCD is valid, take into consideration of the ESCD’s legacy information.
25
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
49
IC-408 Miscellaneous
26
1. If Early_Init_Onboard_Generator is not defined Onboard clock generator initialization. Disable respective clock resource to empty PCI & DIMM
slots.
2. Init onboard PWM
3. Init onboard H/W monitor devices
27
28
Reserved
29
1. Program CPU internal MTRR (P6 & PII) for 0-640K memory address.
2. Initialize the APIC for Pentium class CPU.
3. Program early chipset according to CMOS setup.
Example:
onboard IDE controller.
4. Measure CPU speed.
2A
Reserved
2B
2C
Reserved
Code
Description
2D
2E
Reserved
2F
Reserved
30
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
50
IC-408 Miscellaneous
Reserved
31
Reserved
32
Reserved
33
Reset keyboard if Early_Reset_KB is defined e.g. Winbond 977 series Super I/O chips. See also POST 63h.
34
Reserved
35
36
Reserved
37
38
Reserved
39
3A
Reserved
3B
Reserved
3C
Test 8254
3D
Reserved
3E
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
51
IC-408 Miscellaneous
3F
Reserved
40
41
Reserved
42
Reserved
43
44
Reserved
45
Reserved
46
Reserved
47
48
Reserved
49
1. Calculate total memory by testing the last double word of each 64K page.
2. Program write allocation for AMD K5 CPU.
4A
Reserved
4B
Reserved
4C
Reserved
4D
Reserved
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
52
IC-408 Miscellaneous
4E
4F
Reserved
50
51
Reserved
52
53
54
Reserved
55
Code
Description
56
Reserved
57
58
Reserved
59
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
53
IC-408 Miscellaneous
5A
Reserved
5B
(Optional Feature)
Show message for entering AWDFLASH.EXE from FDD (optional)
5C
Reserved
5D
1. Initialize Init_Onboard_Super_IO
2. Initialize Init_Onbaord_AUDIO
5E
Reserved
5F
Reserved
60
Okay to enter Setup utility; i.e. not until this POST stage can users enter the CMOS setup utility.
61
Reserved
62
Reserved
63
64
Reserved
65
66
Reserved
67
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
54
IC-408 Miscellaneous
68
Reserved
69
Turn on L2 cache
6A
Reserved
6B
Program chipset registers according to items described in Setup & Auto-configuration table.
6C
Reserved
6D
6E
Reserved
6F
70
Reserved
71
Reserved
72
Reserved
73
Reserved
74
Reserved
75
Detect & install all IDE devices: HDD, LS120, ZIP , CDROM.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
55
IC-408 Miscellaneous
76
(Optional Feature)
Enter AWDFLASH.EXE if:
-AWDFLASH.EXE is found in floppy drive.
-ALT+F2 is pressed.
77
78
Reserved
79
Reserved
7A
Code
Description
7B
Reserved
7C
7D
Reserved
7E
Reserved
7F
80
Reserved
81
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
56
IC-408 Miscellaneous
Reserved
82
83
84
85
86
Reserved
87
88
Reserved
89
8A
Reserved
8B
8C
Reserved
8D
8E
Reserved
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
57
IC-408 Miscellaneous
8F
90
Reserved
91
Reserved
92
Reserved
93
94
1. Enable L2 cache
2. Program Daylight Saving
3. Program boot up speed
4. Chipset final initialization.
5. Power management final initialization
6. Clear screen & display summary table
7. Program K6 write allocation
8. Program P6 class write combining
95
96
1. Build MP table
2. Build & update ESCD
3. Set CMOS century to 20h or 19h
4. Load CMOS time into DOS t imer tick
5. Build MSIRQ routing table.
FF
Solution
ID TAUS0800742EN* Solution
Usage
Description
How to enable FTP Publishing Services on Microsoft® Windows XP Pro/Windows 2000/Windows 2000 Server/Windows 2003 Server.
Solution
Please have the Network Administrator perform the setup procedures mentioned in the attached document. To viewthe PDF, Adobe Reader® must be
installed. Adobe Reader® can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
Note : I386 files may be required. The instructions are for Microsoft® Windows XP Pro/Windows 2000/Windows 2000 Server/Windows 2003 Server.
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
58
IC-408 Miscellaneous
Solution
ID TAUS0800854EN* Solution
Usage
Description
IC-408 setup guide for connectivity to MicroPress® 7.5.0.1 system.
Solution
See attached documentation. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
Note : Three patches are required for the IC-408 version 1.1 code for MicroPress®. These patches must be loaded in order.
Patch
Patch 1
2 -- 015k.ps
015n.ps
Patch 3 - 015o.ps
These patches (Micropress-patch.zip) areavailable via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS Expert
Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Please seeattached patch files (foraccessibility incase the Download Selector cannot be accessed).
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0800890EN* Solution
Usage
Description
ow to use Fiery® Pantone© color matching.
Solution
To use Fiery® Pantone© color matching follow this workflow:
1. Print the Fiery® Pantone© color charts.
2. Match the desired color to one of the patches on this chart.
3. Enter the number for the selected patch on this chart into the application as the Pantone© color.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0800892EN* Solution
Usage
Description
"Fiery® Command WorkStation™ License Verification Error" message when attempting to preview a job in the hold queue.
Solution
CAUSE: Job is not processed in the hold queue.
Solution
ID TAUS0801040EN* Solution
Usage
Description
How to find/display the MAC address in a Macintosh® OS X environment (versions 10.1, 10.2, 10.3, 10.4, 10.5).
Solution
Please perform the procedures mentioned in the attached documentation. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be
downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0801045EN* Solution
Usage
Description
How to check Java version on a Macintosh® OS 10.X.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
59
IC-408 Miscellaneous
Solution
To check Java version on a Macintosh® OS 10.X:
Open a Finder window=> select the base HD=> select Applications=> select Utilities=> select Java.All installed versions of Java will be listed.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0801095EN* Solution
Usage
Description
Is the memory upgrade patch required with IC-408 version 1.1 system code.
Solution
The memory upgrade patch is no longert required with IC-408 version 1.1 system code.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0801096EN* Solution
Usage
Description
Minimumversion firmware required for the IC-408 version 1.1 system code.
Solution
The bizhub PRO C6500 version 30 is the minimum version firmware required to support IC-408 version 1.1 system code. Please refer to the attached
ReadMe file for details. To viewthe PDF, Adobe Reader® must be i nstalled. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0801104EN* Solution
Usage
Description
Is PCL printing supported with the IC-408 version 1.1 system software?
Solution
PCL printing is supported with the IC-408 version 1.1 system software. The PCL6 print driver is located on the User Software DVD.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0801249EN* Solution
Usage
Description
How to print to the HOLD queue. "Print Queue Action" selection not available in driver after updating system code.
Solution
"Print Queue Action" menu is no longer in same location as early version of system code drivers.To set Print Queue Action:
File=> Print=> Properties=> Job Info tab=> Scroll down=> Option is now located at bottom of window.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0801310EN* Solution
Usage
Description
Are version 2 ICC profiles from 1.0a system code patch 1-UP600 included in 1.1 code?
Solution
The version 2 ICC profiles contained in patch 1-UP600 for version 1.0a (for example Fiery® 65C-KM Coated G v2.icc) are included in the software for newly
ordered Fiery® systems but not included in the downloaded or ordered system code update software. To obtain these profiles, install the attached 1-VNT51
patch.The patch is alsoavailable via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on
'Download MSDS, Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0801374EN* Solution
Usage
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
60
IC-408 Miscellaneous
Description
Can users be added for User authentication to the IC-408 using the web browser?
Solution
The IC-408 Fiery® controller does not support the addition of any users for user authentication via the web browser. The PageScope applications do not
support this functionality with the IC-408 either. Users can only be added via the operation panel. SPECIAL NOTE : Solution contribution by Greg Lantowski,
Production Print/SSD
Solution
ID TAUS0801914EN* Solution
Usage
Description
Is FreeForm® 2 supported?
Solution
FreeForm® 2 is supported on the IC-303, IC-305, IC-408 with system code versions 1.1 and higher.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0802453EN* Solution
Usage
Description
Graphic Arts package option, what's included?
Solution
The Graphic Arts Package option includes the features listed below:
Halftone Printing
Auto Trapping
TIFF/IT Input
Paper Simulation
HKS, Toyo & DIC spot color libraries
Unlimited Separations
Soft Proofing
Hot Folders
Spot On Color Matching
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0802457EN* Solution
Usage
Description
How to create, export, change, restore and delete a preset.
Solution
Save a preset for frequently used print settings
You can save print settings needed for different applications or types of jobs as a preset.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
61
IC-408 Miscellaneous
Delete a preset
1. In the Start menu, choose Settings => Printers (Microsoft® Windows 2000) or Printers and Faxes (Microsoft® Windows XP/Server 2003).
2. Right-click the desired printer and choose Printing Preferences.
3. Click the Fiery® Printing tab.
4. Under Preset, choose Save and manage list of Job Templates. The Job Templates dialog box appears.
5. Select the preset you want to delete and click Delete.
6. Click OK to close the Job Templates dialog box.
Note: Please see attachment for Screen procedures. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from
the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0802727EN* Solution
Usage
Description
Signature Booklet creation using Microsoft® Office Word 2003/2007.
Solution
Please see the attached document outlining the procedure to create Signature Booklets on a Fiery® IC-303/IC-305/IC-408, using Microsoft® Office Word
2003/2007. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at :
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0802749EN* Solution
Usage
Description
How to create Hot Folders.
Solution
Please see attachments for completestep-by-step procedures. To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for
free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0802752EN* Solution
Usage
Description
How to calibrate an X-Rite DTP32 and DTP34.
Solution
To calibrate an X-Rite DTP32 and DTP34, please perform the step-by-step procedures mentioned in the attached documentation. Also pleasewatch
thevideos.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0802763EN* Solution
Usage
Description
Connecting a Fiery® controller to Novell® 4.1 (if NDPS plug-in is installed) or 5.x using NDPS.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
62
IC-408 Miscellaneous
Solution
Please perform the step-by-step procedure mentioned in the attached documentation. To viewa PDF, Adobe Reader® must be installed. Adobe Reader® can
be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0802783EN* Solution
Usage
Description
Tabloid (11x17) booklet creation on the Fiery® IC-408, IC-303 and IC-305 using Microsoft® Word 2003 and Microsoft® Word 2007.
Solution
To create a tabloid (11x17) booklet:
1.Select Properties.
2.Select the Finishing Tab.
3.Select Stapling: Center.
4.Select Fold: Multi Half Fold.
5.Select the Layout Tab and select Booklet => Sett ings.
6.Select Saddle Left.
7.Select Next.
8.Select Cover is not prepared.
9.Select Next.
10.Select Paper Size for 2-up and choose 8½x11S.
11.Select Next.
12.At the Spine.
13.Select Next.
14.Confirm all your settings and select Finish.
15.Select OK.
16.Select OK.
Note : For a complete step-by-step procedure please see the attached file. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be
downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0808181EN* Solution
Usage
Description
How to save or migrate Preset settings to workstations.
Solution
Please perform the step-by-step procedure mentioned in the attached documentation. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader®
can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0808234EN* Solution
Usage
Description
Where are the ICC color profiles stored on a Macintosh OS X system?
Solution
Color Profiles are stored in the Libraries ? Colorsync ? Profiles folder.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0808258EN* Solution
Usage
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
63
IC-408 Miscellaneous
Description
How to install “Print Services for UNIX” on a Microsoft® Windows 2000 computer.
Solution
To install “Print Services for UNIX” on a Microsoft® Windows 2000 computer:
1. Open the Start => Set tings => Network and Dial-up Connections dialogue.
2. In this window, click on the “Add Network Components” link.
3. With your Microsoft® Windows 2000 installation CD in the drive, checkmark “Other Network File and Print Services;” Next.
4. The “Print Services for UNIX” should then install. You will now be able to set up an LPR connection to your Fiery® controller.
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0808657EN* Solution
Usage
Description
How tofind the Fiery® MAC address.
Solution
The Fiery® MAC address is listed on the Configuration page under Network Setup and is listed as the Ethernet address.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0900331EN* Solution
Usage
Description
Is the IC-408 P ersonalized Print Markup Language (PPML) compliant?
Solution
The IC-408 does not support PPML. Ifneeded, the IC-303/IC-305 must be used.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0900573EN* Solution
Usage
Description
Ascending/descending setting for FreeForm™.
Solution
To enable FreeForm™ with ascending/descending:
1. On the Command WorkStation™, select Server => Setup => V DP.
2. Click "Job" in the "FreeForm 1 Record Length".
3. Click "Apply", then reboot the controller.
SPECIAL NOTE : Solution contribution by KMBT (Japan).
Solution
ID TAUS0900706EN* Solution
Usage
Description
How to add fonts.
Solution
To add Fonts to a Fiery® controller follow these procedures:
1. Open Command WorkStation™ (CWS).
2. In CWS select Server.
3. Select Manage Fonts.
4. Select PostScript then select Add.
5. Browse to the folder where purchased printer fonts were saved and select the fonts to be added, t hen select OK.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0900708EN* Solution
Usage
Description
Can the Fiery® job log be saved as a file?
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
64
IC-408 Miscellaneous
Solution
The Fiery® job log can be saved as a file:
1. Open Command WorkStation™ (CWS).
2. On CWS select Server.
3. Select Job Log.
4. Select Export and Save. The job log will be saved as a text file.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0900744EN* Solution
Usage
Description
Problems when printing from a Fiery®.A file that you have sent t o your fierymay not print.
Solution
Before calling for support there are a few steps you might want to take to fix the problem yourself:
Step 1 . As is always the first step, and sometimes overlooked, is to check the cables and power going to the Fiery® controller and to the printer. We
recommend that the Fiery® be put on a separate power supply that the printer and protected with battery back-up unit, also called a UPS. There have been
cases of power fluctuations ruining hard drives inside the controllers.
Step 2 . Test Network connectivity. If you orthe IT department has the TCP/IP address of the Fiery® controller, try toPING the address to test the network
connection.
Step 3. If by now you still have not found the root of the issue, there may be a problem with your settings or file format. If installed, open up Command
WorkStation™ and see if the file is stuck in the processing or spooling phase. Test to see if the problem only happens when printing a specific file or from a
certain application. Possibly the job has gone through and there was a contradiction with the paper tray settings between the driver and printer settings. If so,
a red warning sign will appear under the printing panel on the right side of your screen. Command WorkStation™ is a valuable application that monitors
workflow and settings of your Fiery® controller. If you do not have this installed on any of your PCs or Macs or would like more information on Fiery®
applications, please get in contact with your service organization.
Step 4. Finally, if problems are still persisting, we ask that you power down the Fiery® controller. Many controllers have a separate power switch on them or
may be stand alone towers. Because the controller is a computer itself, like most computers, it will need to be restarted every once in a while to free up
needed memory.
Solution
ID TAUS0901053EN* Solution
Usage
Description
Can the Fiery® job log be saved in electronic format?
Solution
The Fiery® job log can be saved in electronic format. Follow these procedures:
1. Start Command WorkStation™ (CWS).
2. Select Server.
3. Select Job Log.
4. Select Export.
5. Save the file to t he local workstation.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0901434EN* Solution
Usage
Description
Why job quantity does not count down when printing.
Solution
This is normal operation for this model. The remaining quantity of a job can be viewed from Fiery® Command WorkStation™.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0901462EN* Solution
Usage
Description
How to print text onto a t ab.
Solution
Printing text onto tabs is not supported with the IC-408,but is supported with an IC-305.
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
65
IC-408 Miscellaneous
Solution
ID TAUS0901466EN* Solution
Usage
Description
What is the recommended MD5 checker?
Solution
Therecommended MD5 checker is HkSFV (download attached file).
HkSFV uses CRC-32 and MD5 technology to validate the integrity of files that you have downloaded or moved through a potentially unstable medium (burnt
to CD, transferred over the Internet/LAN). HkSFV can verify your files in seconds and is compatible with Win-SFV and md5sum.
HkSFV is the simple, easy and most automatic application to create or check SFV and MD5 files.
What is an SFV?
An SFV file is a tiny list of files and CRCs, which allow you to check to see if the files you have downloaded are exactly what you are expecting. The CRC
algorithm used in SFV files allows you to see i f the file you have has been changed, even a single byte, since the SFV file was created.
What is an MD5?
MD5 did not exist until somewhat recently, as md5sum is a popular UNIX format similar to SFV and UNIX does not use file extensions the way Microsoft®
Windows-based systems do. MD5 uses the md5 algorithm to computechecksums, rather than the CRC-32method used by SFV. The md5 algorithm is almost
as fast as CRC-32, but it is much more accurate at detecting changes in files.
Some key features of HkSFV:
Easy installation and automatic uninstallation (leaves no trace in the registry, even goes one step further than most programs and restores previous file
associations when you remove it)
One-click creation and checking of SFVs and MD5s
Flawless & smooth upgrading to new versions (simply install the new version)
Automatic association with SFV files, and an option to fix file association when other programs steal it
Handles SFV and MD5 files from any other program invisibly (including files created on *NIX)
Database/cache of previously checked files
Batch SFV and MD5 checking - queue up and check many SFVs and MD5s in one pass, specify a directory and check all the SFVs and MD5s in that
directory (including subdirectories, if you want)
Automatically find renamed files while checking SFV or MD5 files
Enqueue SFVs or MD5s during file verification
Recursive directory support during creation and verification
Supports creation of .bad and .missing files, or deleting failed files
Drag-and-drop SFV or MD5 file or directory to create/check SFV or MD5
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0902078EN* Solution
Usage
Description
How to delete all jobs in the Hold queue in Command WorkStation™.
Solution
To delete all jobs in the Hold queue in Command WorkStation™ (CWS):
1. In Command WorkStation™ select Server.
2. Select Clear Server.
3. SelectHold queue.
4. Select OK.
Solution
ID TAUS0902480EN* Solution
Usage
Description
How to set up Scan to FTP on Microsoft® Windows 2008 Server.
Solution
Please see the attached video for the procedure. The video should be played on Microsoft® Windows Media Player version 9 or later. The latest Media
Player can be downloaded at: http://www.microsoft.com/windows/windowsmedia/default.mspx .
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Solution
ID TAUS0902593EN* Solution
Usage
Description
How to print toFiery® controllers from a Macintosh® running OS 10.6.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
66
IC-408 Miscellaneous
Solution
To print to the current Fiery® controllers from a Macintosh® running OS 10.6, follow the procedure in the attached ZIP file. To open the ZIP file WinZip®
should be installed. WinZip® can be downloaded from the WinZip® website: http://www.winzip.com/ddchomea.htm . The file can either be saved to disk or
opened. It is recommended to download the ZIP and open f rom the local computer to view.
Toview the zippedPDFs, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
Note :Please realize that this is only a workaround untilthe final printer driver version is released by EFI.
SPECIAL NOTE : Solution contribution by Don St . Onge, Workgroup/SSD and Gary Scimeca, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
67
I C-408 Paper Conveyance jams, no-feed, folding, tearing, skewing, curling
Description
J-3201.
Solution
PROBABLE CAUSES:
1.Too much toner on page when printing with high toner coverage. There is a very high toner coveragewith the papersometimes wrapping around the fuser
roller and sticking thus causing the jam.
In the printer driver, select TONER REDUCTION which islocated under the IMAGE tab.
2. Damaged linkage for paper exit gate or failed paper exit solenoid SD4. The jam occurs when duplexing either face up or face down. Paper stops in the
inversion section at reverse roller/Lw before entering the ADU section. All motors and sensors test good in state confirmation mode.
Test SD4 in state confirmation mode 80-0. Repair linkage (p/n 65AA 4928 0) or replace SD4 (p/n 65AA R704 00) if deemed necessary.
SPECIAL NOTE : Solution contribution by Mike McCarthy, Production Print/SSD
Description
Finisher option capable of printing 13x19 jobs to the stapler main tray. The selection is "grayed out" in the printer driver properties for the FS-520/FS-607.
Solution
This is a normal operation with the FS-520 and FS-607 finishers for both print and copy operations. The physical specifications for the FS-520/FS-607
finishers do not support the output of 13x19 paper to the main tray. The paper can only be exited to the sub tray.
Output of 13x19 paper to the main tray is only available with the FS-503or FS-521 stapler finisher.Please refer to the attacheddocument for a listing of the
FS-503/FS-521/FS-520/FS-607 specifications.To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the
Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Tony Pizzoferrato, ESS and Ed Bellone/Mike McCarthy, Production Print/SSD
Description
Tray Ascent or Tray Descent error appears on the controller panel.
Solution
CAUSE: If the paper exiting the finisher is curling too much from lead to trail,the trail edge of the paper contacts the exit tray sensor of the finisher as the exit
tray moves up and down.
SOLUTION: To correct:
1. Change the paper direction, if possible.
2. Try another brand of paper.
3. Verify the paper is kept inthe wrapper untilused.
SPECIAL NOTE : Solution contribution by Gary Scimeca, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
68
I C-408 Software/Driver
related
Description
The entire print job is stapled instead of each set when printing multiple stapled sets from Microsoft® Word.
Solution
CAUSE:The Collate option in the Microsoft® Word dialog box is selected.
SOLUTION:When printing and stapling multiple sets, the Collate option in the Microsoft® Word dialog box must be deselected. Please refer to attached
example. To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from t he Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution byMark D'Attilio and Ed Bellone, Production Print/SSD
Description
Job Properties cannot be viewed within the OS10.4 or 10.5 version of Command WorkStation™. This occurs on both an Intel® and Power PC® version of the
Macintosh®.
Solution
CAUSE: Java update version 6 was installed during an OS update. Java update version 6 is i ncompatible with the current version of Command
WorkStation™, Macintosh® Edition (CWSME).
SOLUTION: An updated version of Command WorkStation™ and its associated utilities has been made available for download. The updated version is
1.5.0f25 for Command WorkStation™ and 3.8.0.22 for ColorWise® Pro Tools. To resolve the issue, follow these instructions:
1.Remove the previous version of CWSME.
2.Decompress the Mac_User_SW_CWSME_1_5_0f25.zip file tothe desktop.
3.In the OSX folder, double-click on the CWSME installer. Ifnot logged in as the administrator, Macintosh® OSX will requirethat a root password is entered.
Follow the installer dialog by entering the appropriate responses for user agreement and installation. Installed CWSME version is 1.5.0f25 andinstalled
Description
HTTP 400 - Bad Request error. Unable to view the printer web browser (PageScope Web Connection).
Solution
CAUSE: The reason for the error:
1. A bad request.The browser sent a request that the server could not understand.
2. An attempt to communicatewith plain HTTP t o an SSL-enabled server port. Instead, use the HTTPS scheme to access the URL.
3.The request could not be understood by the server due to malformed syntax. The client SHOULD NOT repeat the request without modifications.
Note : The first digit of the status code specifies one of five classes of response.
1xx Informational
2xx Success
3xx Redirection
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
69
I C-408 Software/Driver
related
Description
Printing from any driver using an Adobe® CS3 Suite application is very slow. The print job maycomplete quickly, but the application indicates that it is still
printing for a long period after the actual completion. The application is unavailable to perform any other tasks during this period.
Solution
CAUSE: A compatibility issue between a native Intel® application, like Adobe® CS3 Suite applications and the Intel® versionMacintosh® OS 10.4x.
SOLUTION: The best workaround for this issue is to hide the Macintosh® DOCK. The problem appears to be related to how the application interacts with the
DOCK while it is visible. Auto-hiding theDOCK through preferences will correct this printing deficiency. Adobe® and A pple® have not officially acknowledged
this problem, even though it affects printing using any print driver.
SPECIAL NOTE : Solution contribution by Bill Ehmke and Ed Bellone, ESS/SSD
Description
Unable to staple and/or duplex all sheets from Microsoft® Excel with print "Entire Workbook' option selected.
Solution
CAUSE: The staple and duplex selections are only being applied to the first sheet of the Workbook. This issue is with Microsoft® Excel and not related to the
print drivers.
Note : See attached Microsoft® Knowledge Base Articles - 166274, 169033, 214383. To view a PDF, Adobe Reader® must be installed. Adobe Reader®
can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
SOLUTION: The selections for duplex and stapling must be made to each sheet. The selections can made via Pagesetup for each sheet, then selected to
print the "Entire Workbook" from the "Print Dialog" window.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Unable to staple and fold when printing.The commands selected in the printer driver are ignored.
Solution
CAUSE: The media type has not been selected in the driver.
SOLUTION: On the Media tab in the driver, select thepaper type and paper weight when selecting fold or staple.
SPECIAL NOTE : Solution contribution by Mark D'Atti lio, Production Print/SSD
Description
Unable to select Booklet feature when using FreeForm™.
Solution
CAUSE: FreeForm™ does not support the booklet feature.
SOLUTION: Unfortunately, there is no solution that will allow the f unctionality of creating a booklet from a document when using FreeForm™. It is
recommendend to first have document imposed as needed and then utilize FreeForm™.
The IC-303/IC-305 does have an Impose™ module option available that can be used to impose the file prior to utlizing FreeForm™.
SPECIAL NOTE : Solution contribution by Tony Pizzoferrato, ESS/S SD andChuck Tripp, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
70
I C-408 Software/Driver
related
Description
Not all available finishers are not shown in the IC-408 printer drivers.
Solution
CAUSE: Themore recent bizhubC6500/C6501 PRO finishers (FS-521, FD-503, LS-505, PB-503, PF-602 andSD-506) are not compatible with the IC-408.
SOLUTION: If the "newer" finishers are to be used, either the Fiery® IC-303/IC-305 controllers or the CREO© IC-304 controller must be used.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
Unable to install ColorWise® Pro Tools onto a Macintosh® OS 10.x.
Solution
CAUSE: ColorWise® Pro Tools for Macintosh® is an OS 9.x application and will not install on OS 10.x.
SOLUTION: ColorWise® Pro Tools will have to be installed on an OS 10.x Macintosh® in the classic 9.x mode. If the classic mode does not launch when
installing ColorWise® Pro Tools, see the system administrator about loading 9.x or using either a Macintosh® with 9.x already loaded or a Microsoft®
Windows system.
Description
"Spooler subsystem app has encountered a problem and needs to close" message following installation of the PCL driver on a Microsoft® Windows XP
workstation with a small inkjet printer connected via a parallel connection.
Solution
CAUSE: A third-party printer driver or a third-party service prevents adding printers, or the third-party printer driver or third-party service affects the
functionality of a newly installed printer.
Note : As an example, this issue may occur if the Lexmark® print service (LexBce Server service) is installed and is running on the computer before another
printer is added.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
71
I C-408 Software/Driver
related
9. Expand the Version-x subkey or subkeys, and then delete the printer driver entries. To do this, right-click each printer driver subkey, and then click Delete.
Click Yes when prompted to confirm the deletion.
10. Locate and then expand the following registry key:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Print\Monitors
View the list of subkeys. There should only be the following subkeys for the default print monitors:
BJ Language Monitor
Local Port
PJL Language Monitor
Standard TCP/IP Port
USB Monitor
11. If there are any subkeys other than the subkeys that are listed in step 10, follow these steps:
a. On the File menu, click Export.
b. In the File Name box, t ype a descriptive name for this key - for example, type MonitorsRegkey, and then click Save. Use this backup of the
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Print\Monitors registry key to restore the key iif any problems occur after completing this
procedure.
c. Delete all the subkeys other than the subkeys that are listed in step 10.
11. To do this, right-click each subkey that is not on the list, and then click Delete. Click Yes when prompted to confirm t he deletion.
12. If a local printer is attached, disconnect the printer cable from the computer and then restart the computer.
13. Verify that the Print Spooler service is running. To do this, follow these steps:
a. Click Start, right-click My Computer, and then click Manage.
b. Expand Services and Applications, and then click Services.
c. In the right pane, right-click the Print S pooler service, and then click Start (if it is stopped).
d. Quit Computer Management.
14. Reconnect the printer cable to the computer, add the printer and try to print a test page. To add the printer, follow these steps:
a. Click Start, and t hen click Printers and Faxes.
b. Click Add a printer. The Add Printer Wizard starts.
c. Follow the instructions in the Add Printer Wizard to install the printer.
Notes :
-- For additional information about how to manually remove printer drivers, refer to the attached documentation.
-- For additional information about how to troubleshoot printing problems in Windows XP, refer to article numbers 314085 and 308028 in the Microsoft®
Knowledge Base.
-- To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Description
License Verification failed with DocBuilder Pro dongle.
Solution
CAUSE: The computer with the dongle installed does not have the correct Hardlock™ driver installed or there is a driver conflict with LPT1.
SOLUTION: Download and install the latest Hardlock™ driver for the required operating system. Go to http://www.aladdin.com/support/hardlock/index.asp to
access the files.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
Cannot launch Configure from WebTools. Login may appear but configure applet is a grey square.
Solution
CAUSE: Java™ version 1.6.xx may cause conflict on some systems.
SOLUTION: From Microsoft® Windows Control Panel select Add/Remove programs and remove all Java™ updates and the Java™ run-time environment
(may be listed as J2RE) - download version 1.4.2_17 from the Java™ archive site ( http://java.sun.com/products/archive/ )listed under J2SDK/J2RE-1.4. A fter
version 1.4.2_17 is installed relaunch WebTools and launch Configure. If prompted to update, select "Do Not Install", select OK/Allow f or any additional
pop-ups. Login screen will appear and applet will now work.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
How to perform a Mail Merge using Microsoft® Word 2007.
Solution
The attached documentation outlines procedures to:
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
72
I C-408 Software/Driver
related
Description
When printing a large document from Microsoft® Publisher, a Publisher error box displays "There is not enough memory to display a picture. Some pictures
may display incompletely or not at all. To make more memory available, save your work and close other programs: then try again."
Solution
CAUSE: Insufficient hard drive space for the spool folder.
SOLUTION: Confirm the workstation has sufficient hard drive space to spool the print job. The Spool f older location can be confirmed by viewing the Print
Server Properties in Microsoft® Windows by clicking on Start, Settings, and then Printers. The Print Server Properties dialog box opens and now click on t he
Advanced tab to view the spool folder location. The default location for the spool folder for Microsoft® Windows 2000/XP is
C:\\WINDOWS\system32\spool\printers.
If the C: drive space is not sufficient, you may encounter insufficient memory errors when attempting to print which may be more evident with larger print jobs.
If the system is equipped with additional hard drives, the spool folder location can be pointed to a drive with additional hard drive space. Be sure to obtain the
System Administrators approval before making any changes to the spool folder location.
Description
Separate jobs based on name or address are required yet when using Mail Merge, all pages are stapled together.
Solution
CAUSE: A macro should be copied into t he normal.dot document.
SOLUTION: Import word_mail_merge_printing macro into normal.dot. Set up the driver you want to use as the default and then set the finishing features
desired in Printing Preferences. Run normal.dot under macros; you should be presented with a question of how many sections are in the merge (i.e., how
many pages before the next name or address in the merge).
Description
DEMO watermark. Impose License Verification failed on a Dell™ workstation.
Solution
CAUSE: Dell™ computers do not have the correct hardlock driver to recognize the Impose dongle.
SOLUTION: Download and install the latest hardlock driver from Aladdin K nowledge Systems.
Description
Cannot print a tri-fold document from the IC-408 PostScript driver. The print job gets to the IC-408 and stops.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
73
I C-408 Software/Driver
related
Solution
CAUSE: Incorrect settings.
SOLUTION: To resolve:
1. In Publisher go to File=> Page setup=> Printer and Paper=> select your printer=> set paper size to 8.5x11S (this may not be necessary).
2. Now print job to the hold queue or go into File print=> Printing prefrences=> Job info tab=> scroll downand set printer queue action to "process and
hold".
3. Print the job.
4. In Command WorkStation™select Job=> open Job properties=> Basic tab=> change paper size to 8.5x11s and select the tray that has stock
loaded.
5. Under Finishing tab, select multi-trifold in from Folding options.
6. Print thejob.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
When printing from multiple worksheets in Microsoft® Office Excel through an IC-408 or an IC-303 using short edge fed paper (8.5x11S, 8.5x14, 11x17…) set
to staple in any position, the first sheet will will output correctly but the second sheet will jam in the finisher. This happens with the FS-503/FS-520/FS-607. If
job is viewed in Command WorkStation™ thestapling option is not set.
Solution
CAUSE: The first sheet will follow correct paper path through finisher and stops in stacker waiting for other sheets in the set. Af ter the first sheet there is a 3
second pause before sheets 2 through 5 begin printing. Sheet2 does not follow correct path and attempts to bypass stapler section and output to Main tray
where it jams against conveyance section which is still set in the position for stapled sets.
SOLUTION: Select File=> Print=> Select Entire workbook radio button=> Select Properties=> Under "Basic" tab select paper size=> Under "Job
Info" tab scroll down and select "Print Queue Action" to "Process and Hold"=> Click "OK" twice=> Open Command WorkStation™=> Right Click on
desired job and select "Properties"=> Under "Layout" tab set "Scaling" to 100=> under "Finishing" tab select desired stapling option=> Click "Print".
Please see attacheddocumentation for Screen Capture walkthrough.
To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
Macintosh® O/S 10.4 is "crashing" several applications when selecting the printer and when sending the print job.
Solution
CAUSE:Plug-ins from previous models ("konicacover", "konicafinisher" and "konicasetup) arein the li brary folder.
SOLUTION: Remove"konicacover", "konicafinisher" and "konicasetup from the Library on the Macintosh® system.
SPECIAL NOTE :Solution contribution by Mark D'Attilio, Production Print/SSD
Description
When printing from Microsoft® Office Excel using authentication and printng several spreadsheets within the same document, the authentication dialog box
pops up for each spreadsheet page.
Solution
CAUSE: Improper selection in the printer driver.
Description
Unable to load version 1.1 system code on the IC-408. A socket connection error occurs at the PC.
Solution
CAUSE: Microsoft® Windows Vista™ OS is being used to run the system software DVD.
SOLUTION: Microsoft® Windows Vista™ is not supported at this time. Microsoft® Windows XP and Microsoft® Windows 2000 are supported operating
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
74
I C-408 Software/Driver
related
systems.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Description
“Please load 8.5x11 paper “message on t he operation panel when using auto paper select options yet8.5x11 normal stock is loaded.
Solution
CAUSE: Possible incorrect PostScript settings of the Fiery® IC-408 controller.
SOLUTION: Print out a Fiery® configuration page and make sure that the PostScript setupisas follows:
Description
Why the MFP/print controllercannot print multiple page documents from Microsoft® Windows Vista™ 64-bit using Adobe® Photoshop® Elements version 6.
Solution
Adobe® Photoshop® Elements version 6 is not compatible with Microsoft® Windows Vista™ 64-bit.
Note : One can search for application compatibility with Microsoft® Windows Vista™ on the Microsoft web site. Some applications and printer drivers might
be compatible with Vista™ 32-bit, but not Vista™ 64-bit. Always start your check here: http://www.microsoft.com/windows/compatibility/Default.aspx .
SPECIAL NOTE : Solution contribution by Ken Walker, Workgroup/SSD
Description
Fiery® Impose within Command WorkStation™ is reducing/shrinking business cards or documents.
Solution
CAUSE: PostScript setup SCALE TO FIT is enabled/ON.
SOLUTION: Browse to the Fiery® controller via the Fiery® WebTools, launch the Configure (password - Fiery.1) and disable the Scale To Fit under the
Network/PS setup.
SPECIAL NOTE : Solution contribution by Freddie Burnham, Production Print/SSD
Description
When printing a B/W page from Microsoft® Office Publisher 2003/2007 color page click is counted.
Solution
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
75
I C-408 Software/Driver
related
Description
"Adobe Version Incorrect" message when attempting to import/open a document on the Fiery® controller using Adobe® Acrobat® Reader version 9 or
Adobe® Acrobat® Professional version 9.
Solution
CAUSE: Current Fiery® limitation.
SOLUTION:Fiery® will be able to supportAdobe® Acrobat® version 9 products sometime in mid 2009.
SPECIAL NOTE : Solution contribution by Greg Lantowski, Production Print/SSD
Description
How to remove Fiery® printer driver PPD from Macintosh® OS 10.x.
Solution
To remove drivers and PPDs from Macintosh® OS 10.X use the Fiery® Removal Utility. The DriverRemover.dmg file is attached.
SPECIAL NOTE : Solution contribution by Chuck Tripp and Cesar Jimenez, Production Print/SSD
Description
Command WorkStation™ (CWS) not displaying all properties of print job. The print job propertieswhen viewed in CWS only have three tabs: Basic, Job Info
and Summary. Missing are Media, Layout, Color, Image, Finishing, VDP and St amping.
Solution
CAUSE: Incorrect driver.
SOLUTION: Install latest driver. The latest print drivers are available via the Konica Minolta Download Selector. Access the Selector from t he the KMBS
public site ( http://www.kmbs.konicaminolta.us ) Support & Drivers tab or from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS,
Drivers, Firmware and more'.
SPECIAL NOTE : Solution contribution by Mike McCarthy, Production Print/SSD
Description
Error message “The service Calibrator is currently used by Operator” appears.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
76
I C-408 Software/Driver
related
Solution
CAUSE: IC-408 System code anomaly.
SOLUTION: Install attached patch1-Z92DF on the IC-408 with system code versions 1.1/1.1a/2.0.The patch can also be downloaded from the Konica Minolta
Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
This patch is to resolve the issue after it has occurred. It is not necessary to install this patch in advance.
Notes :
1.Please refer to attached Release Notesprior to patch installation. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded
for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .
2. To open the patch file using WinZip®, WinZip®should be installed. WinZip® can be downloaded from the WinZip® website:
http://www.winzip.com/ddchomea.htm .The file can either be saved to disk or opened.It is recommended to download the ZIP and open from the local
computer to view.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Description
In Microsoft® Publisher 2002/2003, publications/records are not individually collated and stapled when duplexing and using t he Mail Merge feature.
Solution
CAUSE: Registry edit required.
WARNING : In Microsoft® Windows, system configuration information is centrally located in the registry. While this simplifies the administration of a
computer or network, one incorrect edit to the registry can disable the operating system. The following list provides some best practices for using the registry
and Registry Editor safely:
SOLUTION: Microsoft® Publisher can be enabled to individually collate, staple and duplex publications/records when using the Mail Merge feature of
Publisher through a registry edit. This can be done either manually or by a script.
To manually edit the registry
Open the Registry Editor by clicking Start, click Run, type regedit , and then click OK. Go to:
1. HKEY_CURRENT_USER\Software\Microsoft\Office\ \Publisher\Printing
2. Right-click on the Printing folder, select New => String Value.
2. Create new "string value" called: NumberOfRecordsPerBatch
3. Double-click and set the Value Data to 1 . Instead of grouping records together into groups of 10to send to t he printer (Publisher default), the records are
now sent in groups of 1 (i.e., each document is sent separately).
Note : A value for this size setting can be set between 0 and 99999.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
77
I C-408 Software/Driver
related
Solution
ID TAUS0702626EN* Solution
Usage
Description
Problems printing from Quark© 7.01/7.02 (Macintosh® OSX).
Print jobs using Quark© Xpress 7.01 or 7.02 will not print to any Fiery® controller.
Printing out of other applications on the same Macintosh® unitis OK.
Quark© 7.0 from the same Macintosh® presents no problem printing.
Solution
CAUSE: The OSX CUPS filter requires updating.
SOLUTION: Please download the installer fromthe EFIweb site, then install it inthe Macintosh®.
http://services.efi.com/support/drivers/download1.asp?oem=efi
Notes : go to the above web site, then select "OSX CUPS Filter FIX - x.x.xxxx" in the pull-down menu.
1.Please
Filename: CUPS_Installer.hqx
This installer simply updates the CUPS filter to resolve the Quark© issue.
2.For controllers that receive Intel® Macintosh® drivers, this file will provide the same fix for Quark© 7.01 as provided with the Intel® Macintosh® drivers.
SPECIAL NOTE : Solution contribution by KMBT (Japan).
Solution
ID TAUS0703154EN* Solution
Usage
Description
Unable access various print driver functions from Adobe® PageMaker 7.0.
Solution
CAUSE: PageMaker uses just the PPD file from the printer for selecting print driver options. Only PPD features will be available in the driver PPD.
SOLUTION: There is a workaround for this issue that will allow access to all print driver features. This is only for Microsoft® Windows-based systems.
1. Rename the PPD4 folder to anything other than P PD4.
2. Launch PageMaker and open the document. When selecting "Print" from the file menu, an error will occur which reads: "Output may not look as expected.
No valid PPD files were found. Check the PPD4 directory in USENGLSH". Ignore this error and press Continue. If the desired driver is not the default driver,
select it. This error will occur again. Press continue if the error comes up.
3. Press the "Setup" button. This will launch the normal GUI interface of the Fiery® driver. Make any driver selection that would normally be selectable from
any application. This also includes being able to select features that were not part of the PPD file (i.e., Secure Print, User ID, etc.).
Note : The PPDs for all printers installed are stored in the PPD4 folder in PageMaker. When printing to another installed printer PageMaker will not be able
to locate the PPD, and the PPD4 folder will have be renamed back to PPD.
4. This workaround is only to access features available in the Windows-basedDLL driverwhich are not available in the PPD. If these features are required
regularly, and more than one printer is used, it would be better to use another application such as Adobe® InDesign.
SPECIAL NOTE : Solution contribution by Craig Blyther, E SS/SSD
Solution
ID TAUS0703697EN* Solution
Usage
Description
"Access Denied" error message when trying to l oad patches via a Remote Desktop connection.
Solution
CAUSE: Incorrect configuration.
SOLUTION: At the PC, copy the patch f iles that will be installed to a flash drive. Remove the flash drive from the PC and access the Fiery® viaa Remote
Desktop connection. Plug the flash drive back into the PC.Remote Desktopshould now see the flash drive. Unpack the patch files and install them onto the
Fiery®.
SPECIAL NOTE : Solution contribution by Gary Scimeca, Production Print/SSD
Solution
ID TAUS0703811EN* Solution
Usage
Description
Unable to print 11x17 booklets using Microsoft® Office Word. Thedocument prints on 8.5x11 with booklet impositionwhen properties specifiedare 11x
17 with booklet imposition and finishing.
Solution
CAUSE: Incorrect setup.
SOLUTION:Set up all imposition and finishing options under the Properties tab of t he driver. At the main driver screen change [Scale to paper size:] from
None to Tabloid (see attached).
Note : To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
SPECIAL NOTE : Solution contribution by David Aekus, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
78
I C-408 Software/Driver
related
Solution
ID TAUS0800480EN* Solution
Usage
Description
Internal error -5 when printing with finishing features from Adobe® Acrobat® 8.
Solution
CAUSE: Additional PostScript setting is necessary.
SOLUTION: From Adobe®, click File, Print, Advanced, and use the drop down arrow under the Font and Resource Policy. Set the Font and Resource Policy
to Send for Each Page.
Note : Changing the Print method to Language Level 2 will also resolve the problem.
Solution
ID TAUS0801417EN* Solution
Usage
Description
WebDownloader is not listed in WebTools.
Solution
CAUSE: When configuring WebTools, WebDownloader was unchecked causing it not to be displayed in WebTools.
Solution
ID TAUS0801685EN* Solution
Usage
Description
Unable to create and use Fiery® FreeForm from the driver.
Solution
CAUSE: The PCL driver is being used which does not support Fiery® FreeForm.
SOLUTION: Install the PostScript driver if it is not already installed and use it for any Fiery® FreeForm jobs.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD
Solution
ID TAUS0801980EN* Solution
Usage
Description
"Device can not print in accordance w/guidelines pick another printer" message when trying to print postage from Stamps.Com.
Solution
CAUSE: Driver incompatibility.
SOLUTION: Stamps.com states that they will not work with Konica Minoltadrivers.The only thing they will do is print labels, and you have to purchase the
labels from Stamps.com.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0801985EN* Solution
Usage
Description
Booklet is not a selection under printer features in the version 1.1 driver. Booklet had been a selection in previous version drivers.
Solution
CAUSE: Change in specification with version 1.1 code. Booklet is no longer supported from the driver when printing from a Macintosh®.
SOLUTION: Booklet jobs should be printed to the hold queue of Command WorkStation™ and then changed to booklet layout in Command WorkStation™.
Refer to the release notes for the specifics. To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe®
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
79
I C-408 Software/Driver
related
Solution
ID TAUS0802329EN* Solution
Usage
Description
Cannot print from a Macintosh® client running OS 10.4.x. When the print icon is selected, nothing happens.
Solution
CAUSE: A specific PPD plug-in may be invalid.
Solution
ID TAUS0802412EN* Solution
Usage
Description
Slow printing issue when utilizing Macintosh® OS 10.4.x.
Solution
CAUSE: Issue with the CUPS daemon configuration file on Macintosh® OS 10.4.x. being corrupt.
SOLUTION: The old CUPS daemon configuration file must be deleted and a new one created. Please see the attached document for instruction on how to
remove and re-create the daemon configuration file.
SPECIAL NOTE : Solution contribution by Tim Blevins - KMBS/Cleveland
Solution
ID TAUS0802473EN* Solution
Usage
Description
The Fold feature is grayed out in the Macintosh® OS 10.x driver. The correct finisher is selected in the driver.
Solution
CAUSE: The Fold feature will appear grayed out if the incorrect paper size is selected in the application .
SOLUTION: In the application, select File\Page Set Up and select either Letter R or 11x17 size paper. These are the two sizes of paper that can be folded.
SPECIAL NOTE : Solution contribution by Gary Scimeca, Production Print/SSD
Solution
ID TAUS0808005EN* Solution
Usage
Description
"Master Installer.exe Needs To Be Loaded" error message when loading Command Workstation™ (CWS).
Solution
CAUSE:Fiery® MasterInstaller application is not installed on the workstation.
SOULTION:The Fiery® Master Installer application is required to install\update EFI® user software.Please reference the attached Fiery® tech note for further
information. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Gregg Gallant, Production Print/SSD
Solution
ID TAUS0808425EN* Solution
Usage
Description
Tabloid (11x17) booklet creation on a Fiery® IC-408, IC-303 and IC-305.
Solution
Please perform
downloaded the step-by-step
for free proceduresin
from the Adobe® web sitethe
at: attached documentation. To viewthe PDF, Adobe Reader®
http://www.adobe.com/products/acrobat/readstep2.html . must be installed. Adobe Reader® can be
SPECIAL NOTE : Solution contribution by Cesar Jimenez, Production Print/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
80
I C-408 Software/Driver
related
Solution
ID TAUS0900516EN* Solution
Usage
Description
"This job contains mixed media settings. If you impose this job, mixed media settings will be applied for sheet range rather than page range" messagewhen
printing a job that does not contain mixed media.
Solution
CAUSE: Mismatched driver and Fiery® system software versionsused.
SOLUTION: Ensure that the Fiery® driver version matches the system software version.
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution
ID TAUS0901412EN* Solution
Usage
Description
Calibration screen closes when measuring with the E D-100 in Microsoft® Windows Vista™.
Solution
CAUSE: User Account Control is enabled on Microsoft® Windows Vista™ workstation.
SOLUTION: TurnOFF UAC control (see attached documentation for detailed procedure).
1.Click onStart ? Control Panel ? User Accounts (you maywant to choose Classic View at the control panel for easier access).
2. Select Turn User Account ControlON orOFF.
3.Uncheck Use User Account Control (UAC) to help Protect your computer.
4.Select OK.
Note : To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution
ID TAUS0902011EN* Solution
Usage
Description
Withthe PostScript printer driver, fonts change when using the fold and staple options.
Solution
CAUSE: Incorrect driver settings.
SOLUTION: Enter the driver settings and under the PostScript tab change the "Send TrueType fonts" from "Automatic" to "Outline" or "Bitmap"; also change
the TrueType font setting to "Download as soft font". Making these changes will keep the fonts that aresent with the print job; they will not be substituted.
SPECIAL NOTE : Solution contribution by Greg Lantowski, Production Print/SSD
Solution
ID TAUS0902293EN* Solution
Usage
Description
Selected areas, like charts, print in black when color is selected from Microsoft® Excel 2007. Driver is defaulted to black. If color is selected for the entire
document all will print in color.
Solution
CAUSE: Service Pack 2 for Microsoft® Office 2007 has not been installed.
SOLUTION: Install Microsoft® Office 2007 SP2. To install t he Service Pack, run
Microsoft® Update or download from the Microsoft Office Online Downloads page .
SPECIAL NOTE : Solution contribution by Jim Behrends, Workgroup/SSD
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
81
I C-408 Warm-up,wrongdisplay,incorrectoperation,lock-up
Description
Scan to E-mail addresses/one-touchesare not being retained on the MFP.
Solution
CAUSE: System code update required.
SOLUTION: Please download and install IC-408 System Code version 1.1 or greater. The latest version firmware or system software is available via the
Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and
more'.
SPECIAL NOTE : Solution contribution by Clinton Marquardt, ESS /SSD
Description
Error code C-4850 (C4850).
Solution
PROBABLE CAUSES:
1. Firmware update required.
Please update to firmware version 40 or greater. The latest version of firmware, system software or print drivers is available via the Konica Minolta Download
Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Note : If the problem occurs while using the SD-501, install mimimum version 30-GCD for the Saddle Stitcher. A C-4840 (C4840) code may also be
indicated.
Description
Calibration page does not print. There is nomessage on the printer orcontroller that indicates the job was sent.
Solution
CAUSE:Image stabilization control has been disabled on the mainbody(dipswitch 24-2 set to1).
SOLUTION: Set dipswitch 24-2 to0 by accessing Tech Rep Mode => System Setting => S oftware SW Setting.
SPECIAL NOTE : Solution contribution by Rich Raynor, ESS/SSD and Jim Behrends, Production Print/SSD
Description
"Press Start to Restart" messagewhile copying or printing.
Solution
CAUSE: Paper is misfeeding from the paper tray.
SOLUTION: Replace the paper tray feed rollers. Please see the attached Bulletin Number 6198for further information.
To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
82
I C-408 Warm-up,wrongdisplay,incorrectoperation,lock-up
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Clinton Marquardt, ESS /SSD andEd Bellone, Production Print/SSD
Description
The IC-408 controller is not recognized when connected to the bizhub PRO C6500.
Solution
CAUSE: Incorrect settings.
SOLUTION: Soft switch 2-1 must be set = to 1 in order to recognize the IC-408 controller. The default setting is 2-1 = 0.
SPECIAL NOTE : Solution contribution by Greg Lantowski, Production Print/SSD
Solution
ID TAUS0703316EN* Solution
Usage
Description
OT-502,printing does not stop after tray is full.
Solution
CAUSE: Firmware bug.
Solution
ID TAUS0801106EN* Solution
Usage
Description
Controller button is blank on the MFP and the Fiery® web page is completely functional when browsing out to the controller, but it indicates “Establishing
Serial Connection”.
Solution
CAUSE: The controller is not communicating with the machine image processing board (IPB) due to abad connection or possibly amalfunctioning video
cable.
SOLUTION: Try flipping or reversing the ends of the video cable and reconnecting; tighten securely. Replace the cable (p/n 45053602) as necessary.
SPECIAL NOTE : Solution contribution by Freddie Burnham, Production Print/SSD
Solution
ID TAUS0801833EN* Solution
Usage
Description
If interrupt copy is performed during printing and a jam occurs or the interrupting copy job is deleted, the controller locks up indicating “Printing” on Command
WorkStation™.
Solution
CAUSE: Firmware update required.
SOLUTION: Please update to firmware version 40 or greater. The latest version of firmware, system software or print drivers is available via the Konica
Minolta Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Solution
ID TAUS0802756EN* Solution
Usage
Description
Controller is calling for incorrect paper size when inserting tabs.
Solution
CAUSE: Firmware bug.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
83
I C-408 Warm-up,wrongdisplay,incorrectoperation,lock-up
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
84
IC-408
Description
When using the new version ES-1000 with EFI Spot-On® (serial numberrange of 870000 to 899999), the device is not recognized by the application. The
device works correctly when using it for calibration.
Solution
CAUSE: Thecurrent shipping versions of ColorWise™ Pro Toolswhich were released before January 19, 2007 contain a configuration file for the Spot-On®
application which references valid ES-1000 serial numbers. The serial numbers of the currentshipping devices areoutside of the valid serial number range as
defined by the configuration file.
SOLUTION: If ColorWise™ Pro ToolsSpot-On® does not connect tothe ES-1000, but ColorWise™ Pro Tools Calibrator® does, it is easy topatch any
installed version of ColorWise™ Pro Tools by replacing the existing 'Spoton.Device' file with the updated version distributed in1-SJZB3.zip which is available
forNotes
download
: from the Download selector or is attached to this solution along with t he Release Notes.
1. The standard location of Spoton.Device is:
a. Microsoft® Windows computers: <Program Files\Fiery\ColorWise Pro Tools>
b. Macintosh® OS X computers: <Applications\Fiery\ColorWise Pro Tools >
2. To open the file(s) using WinZip®, WinZip® must be installed. WinZip® can be downloaded from the WinZip® website:
http://www.winzip.com/ddchomea.htm . The file can either be saved to disk or opened. It is recommended to download the ZIP and open from the local
computer to view.
3. To view the document, Microsoft® Word® or Word® Viewer must be installed. Word® Viewer 2003 (11.7MB) can be obtained free from Microsoft® at the
following URL; http://www.microsoft.com/downloads/details.aspx?DisplayLang=en&FamilyID=95e24c87-8732-48d5-8689-ab826e7b8fdf .
Description
Troubleshooting common FTP configuration problems.
Solution
COMMON FTP CONFIGURATION PROBLEMS
* The username or password is not correct. The password is usually case sensitive.
* FTP is configured using a PORT other than PORT 21.
* After several unsuccessful logon attempts, the account has been locked out.
* Firewall software is installed between the printer and the FTP server. The firewall is configured to block PORT 21.
* The FTP server is located on a different network segment and the gateway address is not configured on the NIC.
* The file path is not configured or is incorrectly configured.
* A " / " must be entered for files that are going to the root of an accounts FTP directory.
* User account only allows 1 simultaneous logon and the account is being used by someone else.
* The user account does not have upload permissions to write to a folder.
* Scanned files are being sent to a nonexistent directory and the user account does not have permission to create a directory.
* The user account has a disk quota assigned to it and it has been exceeded.
* The FTP server is outside the customer's network and must pass through a proxy server for access; The KMBS NICs cannot be configured for proxy access.
Description
IE7 Internet Explorer 7 errors when launching the Fiery configuration utility that is used on all system 8 Fiery's.
Solution
Currently, EFI does not support WebTools and Configure utilities with Microsoft’s newly released Internet Explorer 7 (IE7). These applications may not launch
correctly when used with IE7. EFI is currently working on a fix for this issue for current Fierys.
Description
How to retrieve scan to HDD using Fiery® Remote Scan 5.
Solution
To retrieve scan to HDD using Fiery® Remote Scan 5, perform the following:
1. Connect to the controller using Fiery® Remote Scan 5.
2. Enter box name and password. If scanned to guest boxuse guest with no password.
3. Select the file and then select Send.
4. On the next screen check Save to Disk and select Save As.
5. Browse to location to save, name file and save.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
85
IC-408
Description
Custom paper sizes will not print from QuarkXPress®.
Solution
CAUSE: Paper tray settings are set to mm.
SOLUTION: Change the paper tray settings to inch. To change the paper tray settings to inch, perform the following:
1. Press [Utility/Counter].
2. Select [User Setting].
3. Select [System Setting].
4. Select [Unit Setting].
5. Select the desired setting [mm], [Inch (decimal)], [Inch (fraction)] and select [OK].
6. Exit the User Setting mode.
Description
List of equipment that is no longer being supported.
Solution
Please see attached Product & Technical Support Bulletins 1792 and 2443 andMarketing Bulletin#07-GB-016.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Description
Unable to print using Account Track.
Solution
CAUSE: The "Advanced Printer Features" is enabled on the shared print driver.
Having this option enabled prevents proper operation of ECM (User ID) settings made in the driver under Fiery® Printing -> Owner Information.
The data input into the Owner Information fields does not carry over to printer when printing through a shared queue.
SOLUTION: To Disable (uncheck) the "Advanced Printer Features", perform the following;
1. From the shared printer on the server, right click and open the P roperties window.
2. Select the Advanced tab.
3. Disable (uncheck) the "Enable advanced printer features" located at the bottom of the window.
4. Click APPLY to save the change.
Description
The user and setup guides indicate the IC-408 is shut down from t he bizhub PRO C6500 control LCD. There is no option to perform this task f rom the LCD.
Solution
CAUSE: EFI documentation is incorrect. The correct procedures are listed in the Japanese documentation, but not in t he English documentation.
SOLUTION: The correct method to shut down the IC-408:
1. Use the soft power button or the main power switch on the IC-408. Which method used depends on the reason for powering down.
a.If the controller needs to be disconnected or removed from the C6500, use the main power switch.
b. If just powering down to load system code or some other administrative task, use the soft power button.
Note :Hold down the soft power button for about 5 seconds to power down. When using this method, there is still a small amount of power being applied to
the controller as it is not completely OFF.
2.Using either method, the system will have a delay to write data before powering down. This prevents the possibility of corrupting the system by shutting
down improperly.
Description
How to setup Scan-to-Mailbox (scan to hard drive) on a Fiery IC-408.
Solution
SOLUTION:
Please see the attached PDF for detailed instructions. It includes setting up a mailbox and various ways to retrieve scanned files, including:
1. Fiery WebTools
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
86
IC-408
NOTE: The file is approximately 3MB, so it will take a little time to download.
Description
How to enable scan to E-mail.
Solution
Scan to E-mail can usually be set up from the controller setup but due to the limited setup features on the IC-408 it can only be done using a web browser.To
enable scan to E-mail perform the following:
1. Access the controller with a web browser.
2. Select Webtools.
3. Select the Configure Tab.
4. Select Launch Configure.
5. Select yes on all security warnings for the new window.
6. Log in as Administrator using the password of "Fiery.1".
7. Under Network, Services, Email input the settings provided by the customer.
8. Select Apply and Reboot to save the settings.
Note : Any other setting that may be requiredshould be performed at this time prior to rebooting.
Description
How to get an Activation Certificate or Authorization Code to activate EFI controller features
Solution
SOLUTION:
When an EFI option is purchased, you receive a certificate with a certificate number. You must get an authorization code from EFI to activate t he features
on the controller.
The code is obtained from http://www.efi.com/activation .
Follow the onscreen instructions to obtain the code. You will need the 16-digit system ID code from the controller on which the option is being installed. The
ID code is in the upper left section of the controller configuration page. After a code is obtained, the option is activated from the Setup > Enable Options
menu on the controller.
Notes:
1. For further information on enabling the options, refer to the Activating Options on the IP-921/X3e 50C-K document.
2. To view the PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloaded for free from the Adobe* Web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Description
Side 2 of booklets print upside-down.
Solution
CAUSE: Binding position is set incorrectly in the Fiery® driver.
SOLUTION:Set booklet to Left Binding under the Layout tab of the Fiery® driver.
Description
When searching solutions by models,referenced links for the documentsare notaccessible.
Solution
CAUSE: This is a search of the printed database. The links are locatedwithin the solution in the database.
SOLUTION: Copy the solution ID number into the Knowledgebase look-up Keyword field and select Search to access the solution complete with active links
to attached documents.
Note : If there is an actual 'dead' link within the solution, please send an E-mail to [email protected] with the solution ID number and please
identify the link.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
87
IC-408
Description
How to create Signature Booklets from either Adobe® Acrobat™ or Microsoft® Office Word.
Solution
To create Signature Booklets from Adobe® Acrobat™:
1. Select File.
2. Select Print.
3. Choose the IC-408 and click Properties.
4. In the Basic Tab, select:
a. Duplex: Right & Left Binding
b. Paper Size: 8½x11S
c. Orientation: Portrait
5. In the Layout Tab select:
a. Booklet Maker: Saddle-Left Binding
b. "Booklet Best Fit"
6. In the Finishing Tab select:
a. Fold: Multi Half Fold
b. Stapling: Center
7. Press OK twice.
Description
ColorWise™ Pro Tools causes a Java™ error when launched.
Solution
CAUSE: An incompatible version of Java™ is installed on the computer.
SOLUTION: Remove the existing version and install Java™ 5, version 2. It is available with the Command WorkStation™ installation or from the Java™
download archives .
Description
Unable toscan to SMB.
Solution
CAUSE: DNS server TCP/IP address is not entered on the Fiery®.
SOLUTION: In Fiery® Setup, enter the TCP/IP address for the DNS server.
Description
How to determine what version of Sun Java™ is installed on a Microsoft® Windows workstation.
Solution
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
88
IC-408
Description
How to activate EFI features.
Solution
SOLUTION:
See the attached filecomplete instructions.
Note: To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Description
Unable to configure options on the PostScript driver after downloading the shared driver from Fiery® controllers (running Microsoft® Windows). The Add
button and Update button are grayed out.
Solution
CAUSE: The driver installed locally on the Fiery® controller is incorrectly configured.
SOLUTION: From a workstation in the local subnet access the Fiery® controller using Microsoft® Windows Remote Desktop:
User id:administrator
Password:Fiery.1
1.In the Printer and Faxes window (Start=> Settings=> Printers and Faxes) right-click on the Print object and select Properties.
2.Confirm that Two-Way Communication is checked and localhost is defined as the printer TCP/IP Address or DNS name.
3.Click UpdateDesktop.
4.Exit Remote or Defaults to populate the Installed Options field with the correct items.
5.Download the configured print driver from the Fiery® controller to the workstation using the SMB method (above).
6.Confirm that the driver options are configured correctly by checking properties of t he new driver.
Note : It may be necessary to delete the previous printer object and print driver (using server properties) reboot the workstation, then install the shared
driver from the Fiery® controller.Please review the attached PDF containingscreen shots for further detail.
Description
Print jobs are automatically deleted when a paper mismatch occurs.
Solution
CAUSE: The Fiery® controller default settingautomatically deletes the print job when a paper mismatch occurs.
SOLUTION: In Fiery® server set up, set Enable Cancel on Mismatch to NO. To set the Enable Cancel on Mismatch setting, perform the following:
1. Connect to the Fiery® using a web browser.
2. Select Web Tools.
3. Click on the Configure tab.
4. Click on the Launch Configure tab.
5. Enter the Fiery® password. The default password is 'Fiery.1'.
6. Select Server.
7. Select Jobs.
8. Under Job mismatch, uncheck the Enable Mismatch Action check box.
9. Click Apply.
10. Click Reboot.
Description
Images are scaled too small when printing a booklet.
Solution
CAUSE: If the image is already correctly scaled for the booklet, selecting 'Bookletbest fit' may cause the document to be scaled within the printer margins. If
the document margins are already the correct size this may not be desired.
SOLUTION: Do not select 'Booklet best fit' in the driver if the document is already correctly scaled.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
89
IC-408
Description
Color Profiler® and Command WorkStation™ crash on a Macintosh® with an Intel® processor.
Solution
CAUSE: Old utilities for the "non-Intel" Macintosh® computers are being used.
SOLUTION: EFI has released utiliti es that support the Intel®-based Macintosh® computers.
Note : These utilities are available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS Expert Support) by clicking
on 'Download MSDS, Drivers, Firmware and more'.
Description
Cannot select a different paper source at the machine panel when printing.
Solution
CAUSE: Enable Job Mismatch isselected.
Description
Blues print purple when printing from Adobe® Acrobat®.
Solution
CAUSE: 'Use Media Defined Profile' is set in the printer driver.
SOLUTION: Change the output profile in the driver to use the Server Default Profile. To do this, perform the f ollowing:
1. Select File =>Print.
2. Click [Properties].
3. Select [Color].
4. Click [Expert Settings].
5. Select the [Use Server’s Default].
6. Click [Update].
7. Click OK three times to print t he document.
Description
Print job prints properly but they are not listed in the Printed Jobs list in Command WorkStation™ (CWS).
Solution
CAUSE:LPR queue name is set to Direct in the Fiery® print driver. This causes the print job to only go intoRAM on the Fiery® andif the Fiery® is restarted,
these jobs will not be listed in CWS.
SOLUTION: Change the LRP queue name to Print. This setting allows t he print job to be stored on the Fiery® hard drive (normal operation).
Description
Will installed options such as FACI or Production Print be lost if Fiery® system code is reloaded?
Solution
Installed options will not be lost if Fiery® system code is reloaded. This information is storedin the Fiery® motherboard BIOS.
Description
How to print to a printer on a Microsoft® Windows XP PC from a Macintosh® running OS version 10.4.x.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
90
IC-408
Solution
Please perfrom the step-by-step procedure mentioned in the attached document.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Description
Number of pages/sets remaining in a job is not displayed when printing.
Solution
CAUSE: This is specification for this machine. It will not display the pages/sets remaining in a print job on the mainbody display.
SOLUTION: This information can be viewed in EFI Command WorkStation™ (CWS)version 4.5 or higher. CWSwilldisplay the pages/sets remaining in a print
job.
Description
The IC-408 is not recognized by the bizhub PRO C6500.
Solution
CAUSE: Incorrect settings or corrupt system code.
SOLUTION: Verifiy that DipSW 2-1=1 to allow recognition of the IC-408. If the DipSW is set correctly, reload system code to correct the recognition issue.
Note : The latest version firmware or system software is available via the Konica Minolta Download Selector. Access the Selector from SS D Web Support
(CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Solution
To set up a secure mailbox on the IC-408 controller, perform the following:
1. Access the IC-408 home page with a web browser.
2. Enter the Admin password to access Admin Mode for Mailbox (default is ' Fiery.1').
3. Select Create Mailbox.
4. Enter desired name and password and select Apply.
5. Log out of Admin mode.
Description
How to set up a one-touch scan to HDD for a secure mailbox.
Solution
To set up a one-touch scan to HDD for a secure mailbox, perform the following on the machine LCD display:
1. Select Scan.
2. Select HDD.
3. Select Address Input.
4. Select and enterthe secure mailbox name for theBox Name.
5. Enter the desired information into the Register name and Search Character.
6. SelectRegister to enter into address list.
Description
Performing calibration using EFI ColorCal™ will produce poor output quality.
Solution
CAUSE: This is a system code bug in IC-303version 1.01 or IC-408 version 1.0.
SOLUTION:
patch EFI has released
file'designation' a patch
is different when for the IC-303
searching foritand IC-408
in the KMBS that resolvesSelector.
Download this issue. Patch 1-QJYP5.exe is for both the IC-303 and the IC-408, but the
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
91
IC-408
In the Download Selector, 1-QJYP5.zip is for the IC-303 and 1-RKPWY.zip is for the IC-408, yet both ZIP files contain the 1-QJYP5.exe patch file and
Release Notes for each controller.
Notes :
1. Attached is the patch file and corresponding Release Notes.
2.The patch only applies to version 1.01 (IC-303) or 1.0 (IC-408) system code and will come bundled into the next release version of system code.
3. The latest version firmware and system software is available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS
Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
4. To view the document(s), Microsoft® Word® or Word® Viewer must be installed. Word® Viewer 2003 (11.7MB) can be obtained free from Microsoft® at
the following URL; http://www.microsoft.com/downloads/details.aspx?DisplayLang=en&FamilyID=95e24c87-8732-48d5-8689-ab826e7b8fdf .
Description
FD-501, Z-fold is incorrect on second and subsequent sheets fed from main body trays as compared to Post Inserted jobs.
Solution
CAUSE: Incorrect version firmware on the FD-501.
SOLUTION: Install FD-501 (multi-folder H) version15BM0Y0-00H1-G00-20 or higher on the FD-501 when the bizhub PRO C6500 is running version 25 or
higher.
Note : The latest version firmware or system software is available via the Konica Minolta Download Selector. Access the Selector from SS D Web Support
(CS Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Solution
ID TAUS0655608EN* Solution
Usage
Description
Are Konica Minolta MFPs compatible with Category 6 cable standard?
Solution
Konica Minolta MFPs are fully compatible with Category 6 cable standard.
Category 6 cable is a cable standard for Gigabit Ethernet and other network protocols that is backward compatible with the Category 5/5e and Category 3
cable standards.
Cat-6 features more stringent specifications for crosstalk and system noise. The cable standard is suitable for 10BASE-T/100BASE-TX and 1000BASE-T
(Gigabit Ethernet) connections and it provides performance of up to 250MHz.
Solution
ID TAUS0700350EN* Solution
Usage
Description
How to acquire Command WorkStation™ for installation.
Solution
Command WorkStation™ is available on the controller to download and install. To download, perform the f ollowing:
1. Enter the TCP/IP address of the controller inthe browser.
2. When the web page comes up, select webtools.
3. Select the downloads tab.
4. Select Client Software installer and follow the prompts.
Note : Previous versions of Command WorkStation™ should be removed before installing.
Solution
ID TAUS0700629EN* Solution
Usage
Description
Print quality looks poor after performing calibration when using a densitometer with a serial connection.
Solution
CAUSE: A 3rd-party serial-to-USB adapter is being used to connect the serial densitometer to the computer USB connection.
SOLUTION: Calibrate using the serial densitometer to a computer with a serial connection that does not require any adapter.
Solution
ID TAUS0700719EN* Solution
Usage
Description
Unable to print from AS/400™ using IBM SNMP driver.
Solution
CAUSE: Incorrect AS/400™ configuration.
SOLUTION: This model can be set up as a device printer on the AS/400™. When printing SCS, this setup can be used with the stock controller NIC cards.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
92
IC-408
This setup supports page range control but does not support specific tray calls. In order to support tray call the AS/ 400™ workstation customization table (if
there is one) must be modified.
To load an SNMP driver compatible with the Konica Minolta controller, perform the following:
1. From the Main Menu under Selection or Command, type:crtdevprt
2. Change the following to set up t he printer (those settings not changed, keep at default):
a. Device Description - (name the printer i.e., Konica Minolta)
b. Device Class - *LAN
c. Device Type - 3812
d. Device Model - 1
e. LAN Attach - *IP
f. Port number 9100
g. Font Identifier - 011
h. Form Feed - * Autocut
i. Manufacturer - *HPCOLORLJ
j. Paper Source (both) - *letter
k. Address - (IP address of the NIC)
l. User-defined options - *IBMSHRCNN
m. System Driver (hit F4) - *I BMSNMPDRV
Notes :
A. Vary ON the device to allow attachment.
B. Review the attached configuration for IBM SNMPdriver configuration on the AS/400™.
C. To view a PDF, Adobe Reader® must be installed. A dobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Solution
ID TAUS0700833EN* Solution
Usage
Description
How to display 'held' or 'printed' jobs on the t ouchscreen.
Solution
To display held print jobs on the t ouchscreen, perform the following:
1. Touch [MACHINE] on the touchscreen.
2. Touch [Controller] on the touchscreen.
3. Touch [Job List] on the touchscreen.
4. Touch [Held Jobs] on the touchscreen. The held jobs will be displayed on the touchscreen.
5. To return to the normal screen touch [MACHINE] on the touchscreen.
6. Touch [COPY] on the touchscreen.
Solution
ID TAUS0700913EN* Solution
Usage
Description
How to enable Remote Desktop
Solution
To enable Remote Desktop on the Fiery, perform the following:
1. Go into the Fiery Server Setup
2. Under Server Setup, set Enable Remote Desktop to YES
Solution
ID TAUS0700997EN* Solution
Usage
Description
How to set up scan to HDD for a guest user.
Solution
To set up scan to HDD for a guest user, perform the following on the machine LCD display:
1. Select Scan.
2. Select HDD.
3. Select Address Input.
4. Select and enter desired information for Box Name, Register Name, and Search Character.
5. Select OK to accept for single use or Register to enter into address list.At this time, scan setting can be chosen and the document scanned.
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
93
IC-408
Solution
ID TAUS0701018EN* Solution
Usage
Description
Memory specification for the IC-408.
Solution
The IC-408 comes standard with a 512MB DIMM and is upgradeable to 1GB with an additional 512MB DIMM (p/n 7640002934).
Notes :
1.Patch file IC408_memupgrade.exe is required for installation (see attached4MB file).
2. The latest version firmware and system software is available via the Konica Minolta Download Selector. Access the Selector from SSD Web Support (CS
Expert Support) by clicking on 'Download MSDS, Drivers, Firmware and more'.
Solution
ID TAUS0701019EN* Solution
Usage
Description
IC-408 Gigabit Ethernet support.
Solution
The IC-408 RJ-45 port is for twisted pair (10BaseT/100BaseTX/1000BaseT) network connection. Gigabit Ethernet is supported with the NIC speed set to
Auto.
Solution
ID TAUS0701109EN* Solution
Usage
Description
Controller will not boot after installing the memory patch.
Solution
CAUSE: The memory patch was installed without installing the additional 512MB of memory.
SOLUTION: The memory patch is to allow the controller to recognize the additional memory. If the patch is installed without the additional memory, the
controller will not boot. To resolve, install the 512MB memory upgrade (Item #7640002934). This will increase the memory to a total of 1GB.
Solution
ID TAUS0701154EN* Solution
Usage
Description
How to install Auto Trap.
Solution
SOLUTION:
See the attached file for detailed instructions to install the software onto the USB thumb drive, and instructions for installing the EFI Auto Trap feature.
Note: To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Summary of steps:
1. Items needed:
a. USB_Flash_Program_CD_v3.1.1.iso
b. Feature Activation software, version 1.0, CD for Fiery X3eTY2 Servers.
c. USB thumb drive: minimum 32MB for activating features, 2GB for system software.
d. EFI Auto Trap dongle (item number 7640002569).
2. Be sure your computer boots from its CD drive, not f rom the hard drive.
Note: To enter BIOS, use F2, F3, F8, or DEL during boot (varies by brand). IBM Think Pad R51 usesF1.
3. Turn off the Fiery and the copier.
4. Insert the USB thumb drive and EFI Auto Trap Dongle in the IC-408 USB Port.
5. Turn on the Fiery.You will see the following codes:
a. 00 - Update process is starting.
b. 01 or 02 - Update is in progress.
c. F0 - Update is successful.
d. FF - Update is complete.
6. The Fiery will shut down automatically.
7. Remove the USB thumb drive and the E FI Auto Trap dongle.
8. Turn on the Fiery.
9. Afterthe Fiery isidle, print a configuration page.
Note: EFI Auto Trap will be listed on page 2 under BIOS Setup, Installed Options.
Solution
ID TAUS0701176EN* Solution
Usage
Description
LED error codes (BIOS POST error codes)
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
94
IC-408
Solution
SOLUTION:
See the attached file for a complete list of LED error codes (BIOS POST error codes).
Solution
ID TAUS0701855EN* Solution
Usage
Description
ES-1000 from the EFI™ Color Profiler Kit
Solution
The ES-1000 Spectrophotometer is available with theEFI™ Color Profiler Kit (Item #7640000747).
The EFI™ Color Profiler Kit includes the ES-1000 Spectrophotometer and monitoring profiling software. It works oncomputers running Microsoft® Windows
2000/XP only.
Solution
ID TAUS0701922EN* Solution
Usage
Description
Unable to print on 8½x11 paper from Microsoft® Word. NO PAPER 8½x11S error message is displayed. Page setup in Word and the Fiery® print driver are
set to 8½x11.
Solution
CAUSE: Microsoft® Word options are set for a default paper tray.
SOLUTION: Set the default paper tray to Use Printer Setting in Microsoft® Word options. To configure the options in Word, perform the following:
1. Open Microsoft® Word.
2. Select Options from the Tools menu.
3. Select the Print tab.
4. Using the drop down arrow next to the Default Tray dialog box, select Use P rinter Setting. 5. Select OK.
Solution
ID TAUS0701925EN* Solution
Usage
Description
PLEASE LOAD MILLIMETER SIZE PAPER (305mmX245mm) IN TRAY message in Command WorkStation™ when printing 8.5x11 PDFs to 12x18.
Solution
CAUSE: Incorrect setting in the driver.
SOLUTION: Verify on the print driver, whengoing to print (File Print), that the CHOOSE PAPER SOURCE BY PDF PAGE SIZE is unchecked or deselected.
Solution
ID TAUS0702023EN* Solution
Usage
Description
The entire document prints on the cover stock when printing from PageMaker® 7.0.
Solution
CAUSE: Cover stock is being fed from a tray other then the bypass tray.
SOLUTION: Insert covers from the bypass tray when printing from PageMaker® 7.0.
Solution
ID TAUS0702146EN* Solution
Usage
Description
How to perform Print Screens (screen shots) from a Microsoft® Windows OS and Macintosh® OS.
Solution
Please see the attacheddocument for detailed information.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Solution
ID TAUS0702268EN* Solution
Usage
Description
How to determine if the IC-408 memory upgrade patch (IC408 memoryupgrade.exe) has been installed on the controller.
Solution
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
95
IC-408
The IC-408 memory upgrade patchwill be shown as 1-PWBLX on the IC-408 configuration page.
Solution
ID TAUS0702676EN* Solution
Usage
Description
When sending a print job using Fiery® Freeform the machine locks up.
Solution
CAUSE: The IC-408 code is corrupt.
Solution
ID TAUS0702890EN* Solution
Usage
Description
Printing to a Windows Samba shared printer from a Macintosh®.
Solution
Please perfrom the step-by-step procedure mentioned in the attached document.
Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html
Copyright 2009, Konica Minolta Business S olutions U.S.A., Inc. October 2009
96