F 18 User Manual
F 18 User Manual
User Manual
F18
www.esslsecurity.com
Product Overview
F18
F18 is an innovative biometric fingerprint reader for access control application. Offering unparalleled performance
by using an advanced algorithm for reliability, precision and excellent matching speed. The F18 features the fastest
commercial-based fingerprint matching algorithm and high-performance, high-image quality infrared detection
fingerprint sensor. The device offers flexibility to be installed standalone or with any third party access control
panels .that support standard Wiegand signal. All the operations can be done on the TFT-LCD color screen. The
fingerprint image will be displayed on it. That will guide user to put finger on proper position and increase
recognition rate. TCP/IP and RS485 are available that the device can be used in different network. communication.
Auto-discovery tool allows setting and modification of network parameters directly and easily.
Contents
I
Contents
II
Contents
III
1. Operating Instruction
-1-
F18 User Manual V1.0
Improper press:
Please adopt the correct way to place the finger to avoid improper
operation led to the identification performance degradation.
-2-
F18 User Manual V1.0
Notice:
1) If the device have ID module, so Interface of Matrix and Magic style
can be displayed "Press fingerprint or punch card". When have not ID
module, it can be displayed "Please Press fingerprint" only.
2) The device has three interface styles for option. Each style displayed
different contents on the screen. For details please refer to 4.4 Display Setting.
3)As above the "Name" of screen, you can edit different names can be
executed by "Access Control Management Software ".
Fingerprint Matching
-3-
F18 User Manual V1.0
If device says “Please press again”, and displayed "Verify fail" on the screen.
Return Step 1 for the second operation.
-4-
F18 User Manual V1.0
-5-
F18 User Manual V1.0
Notice:
If device says “Please press again”, return Step 2 for the second operation.
-6-
F18 User Manual V1.0
If device says “Error ID”, that means you input ID number is wrong, please
return Step 1 for the second operation.
Password Matching
Step 1: Input User ID of employee to be verified on initial interface.
Then press OK.
Step 2: If it says that the enroll number is wrong, it means that there is
no such number or the employee does not enroll password.
-7-
F18 User Manual V1.0
-8-
F18 User Manual V1.0
When the screen displayed "password error" and "Input password again"
as shown below:
-9-
F18 User Manual V1.0
Please return Step 3 input password again for the second operation.
Ranges of the input password time is 0~9. Employee can set default
time what you want. For details please refer to 4.4 Display Setting.
Card Matching ★
The card area is round the keyboard.
Step 1: Wave the card near the induction area on initial interface, after
the induction equipment finding the card, please remove the card.
Step 2: When the equipment gives the tip "Thank you", the certification completed.
- 10 -
F18 User Manual V1.0
Step 3: If the card has not registered yet, prompt that card is not registered.
The device only records attendance time. The statement can be disposed
by software on PC. Therefore, it is necessary for device to connect PC to
download attendance record to attendance software.
The following is some connection methods:
Ethernet:
(1) Through hub: Use parallel net cable (to connect network card and
hub) to connect device into the network.
(2) Direct connection: use cross net cable(connect two Ethernet
terminals directly) to connect device and PC.
Set device: Enter Menu-Communication option-Network to set the
following items:
IP address: Default IP as 192.168.1.201.You can modify it if it is
necessary.
- 11 -
F18 User Manual V1.0
RS485
set device: Enter Menu-Communication option to set the following
options:
Device ID: Set it in “Security”. It can be set from 1-254.
Baud rate: Set it in “RS232/485”.Communication speed rate (with
computer),if the communication speed is low and stable, RS 485
(9600, , 38400) is recommended.
RS485: Set it in “RS232/485”.Select “Yes” for RS485
Communication password: Set it in “Security”. It can be set or not. If it
- 12 -
F18 User Manual V1.0
USB
Set device: Enter Menu-Communication option to set the following
items:
Device ID: Set it in “Security”. It can be set from 1-254.
USB: Set it in “RS232/485”.Select “Yes” for USB communication.
Communication password: Set it in “Security”. It can be set or not. If it
is set, input corresponding numerical value on connection interface of
PC software.
On the initial interface, press the Menu key about 3 seconds to open the
Main Menu, as shown in the following figure:
User management: Browse the users’ basic information like ID, name,
fingerprint, card, password and privilege and so on; Increase, edit or
delete operation the basic information; Set the work code for user and
card management.
- 13 -
F18 User Manual V1.0
- 14 -
F18 User Manual V1.0
2. User Management
- 15 -
F18 User Manual V1.0
may entry the menu operation; after the manager is appointed, anyone
is unable to entry the menu until the manager status is confirmed, after
the success can entry the menu:
Press finger according to device’s prompt. Press the finger three times in
the proper way.
If one fingerprint is enrolled successfully, press OK to continue another
finger, then press menu and ESC to return the last interface.
Press ▲/▼ to select “enroll password” and press OK to enroll
password.
- 17 -
F18 User Manual V1.0
Enroll password
Slight ware the card near the induction area, after the equipment found
the card number, press OK key to save, press to give up, then remove
the card from the equipment, after the "Enroll successfully" the card
- 18 -
F18 User Manual V1.0
- 19 -
F18 User Manual V1.0
- 20 -
F18 User Manual V1.0
- 21 -
F18 User Manual V1.0
Notice: The picture may be different from your device. The real
product prevails.
Press ▲/▼ to read attendance record.
Press OK/menu to query detailed information.
Edit user information saved in the device. For example, the former
enrolled fingerprints are unusable, enter “edit user” to re-enroll
- 22 -
F18 User Manual V1.0
- 23 -
F18 User Manual V1.0
- 24 -
F18 User Manual V1.0
Press ▲/▼ to select your desired item, press OK to execute the current
selected item.
Regard Mifare card as ID card use, just register card number, do not need
to enroll the fingerprint.
Operation:
- 25 -
F18 User Manual V1.0
1. Enrollment
Step 1: Select enroll card and then press OK.
- 26 -
F18 User Manual V1.0
Sway the card in the induction area. After the device inducts the card,
move the card off. When the verification is successful, the device will
give prompt.
- 27 -
F18 User Manual V1.0
Step 5: Put the card in the induction area, waiting for the device to read
fingerprint data into card until the enrollment succeeds.
2. Verification:
Sway the card in the induction area. After the device inducts the card,
move the card off. When the verification is successful, the device will
give prompt. If the pressed fingerprint is different from that stored in the
card, the verification will fail.
- 28 -
F18 User Manual V1.0
Put the card in the induction area, waiting for device to delete all the
information in the card. If the card data has been stored in the device,
the device will remind you whether to delete the information in the
device or not. “Yes” is to delete the user’s fingerprint and information in
the device. “No” is to keep the information.
- 29 -
F18 User Manual V1.0
Set password of Mifare card and decide whether the information should
be saved or not.
Fingerprint card password: After the password is set, the device will
write password into the enrolled fingerprint card. Then the fingerprint
- 30 -
F18 User Manual V1.0
Press ▲/▼to move cursor to the item to be set. If it is the input box,
press numeric keys on small keyboard to input the value. If it is the roll
box, press / to switch the values. After setting, press menu directly
to return to the last interface. Press “ESC” to cancel setting and return to
the last interface.
- 31 -
F18 User Manual V1.0
Access control option is to set user’s open door time zone, control lock
and related device’s parameters.
If the device support external facial instrument, it can not support the
camera and advanced access control at the same time.
To unlock, the enrolled user must accord with the following conditions:
1. The current unlock time should be in the effective time of user time
zone or group zone.
2. The group where user is must be in access control (or in the same
access control with other group, to open the door together).
The system default the new enrolled user as the first group, default
group time zone as 1, access control as the first group, and the new
enrolled user is in unlock (if user has modified the related setting of
access control, the system will be changed with user’s modification) .
Operation:
Press Menu -> User Management -> Access Setting (as shown below)
Press ▲/▼ to select your desired item, press OK to execute the current
selected item.
- 32 -
F18 User Manual V1.0
Time zone is the minimum unit of access control option. The whole
system can define 50 time zones. Every time zone defines seven time
sections (namely, a week). Every time section is the effective time zone
within 24 hours everyday. Every user can set 3 time zones, “or” exists
among the three zones. It is effective if only one is satisfied. Every time
section format is HH:MM-HH:MM, namely, accurate to minute.
If end time is smaller than start time (23:57- 23:56), the whole day is
forbidden. If end time is bigger than start time(00:00- 23:59), it is
effective section.
Effective time zone for user unlocking: 00:00-23:59 or the time zone
when end time is bigger than start time.
Operation:
Press Menu -> User Management -> Access Setting -> Time Zone
Setting(shown as below)
- 33 -
F18 User Manual V1.0
Input time zone number. If the enrolled time zone has number already,
then the time zone setting will displayed automatically. Press ▲/▼,
/ to move the cursor to the input box, press numeric key on small
keyboard to input value. Then press Menu to save it and press ESC to
exit.
Add holidays
Press Menu to get operation menu
- 34 -
F18 User Manual V1.0
Press ▲/▼ to move cursor to the input box. Press numeric key on small
keyboard to input the value. After setting, press Menu to save it. Then
press ESC to exit.
Edit holidays
Select the line to be edited. Press OK directly or press Menu to select
edit in operating menu.
- 35 -
F18 User Manual V1.0
Press ▲/▼ to move cursor to the input box. Press numeric key on small
keyboard to input the value. After setting, press Menu to save it. Then
press ESC to exit.
Delete holidays
Select the line to be deleted. Press Menu to select delete in operating
menu.
Notice: If holiday access control time is set, user’s open door time
zone during holiday subject to the time zone here.
- 36 -
F18 User Manual V1.0
Press ▲/▼ to select add. For example, to add a group whose time zone
is 2 and 3, as shown below:
- 37 -
F18 User Manual V1.0
Press ▲/▼to move cursor to the item to be set. If it is the input box,
press numeric keys on small keyboard to input the value. If it is the roll
box, press / to switch the values. After setting, press Menu directly
to return to the last interface. Press “ESC” to cancel setting and return to
the last interface.
3. Delete group time zone
- 38 -
F18 User Manual V1.0
In the Access Group setting interface, select the line to be deleted. Press
Menu to select delete in operating menu.
- 39 -
F18 User Manual V1.0
Press ▲/▼ to move cursor to the input box. Press numeric key on small
keyboard to input value. After setting, press Menu to save it. Then press
ESC to exit.
2. Edit unlock combination
Select the line to be edited. Press OK directly or press Menu to select
edit in operating menu.
Press ▲/▼ to move cursor to the input box. Press numeric key on small
keyboard to input value. After setting, press Menu to save it. Then press
ESC to exit.
3. Delete unlock combination
Select the line to be deleted. Press Menu to select Delete in operating
- 40 -
F18 User Manual V1.0
menu.
Notice: 1) when time zone is set for NO or NC, please set door
sensor mode as “None”, or alarm signal may come out during
time zone of NO or NC.
- 41 -
F18 User Manual V1.0
Press ▲/▼to move cursor to the item to be set. If it is the input box,
press numeric keys on small keyboard to input the value. If it is the roll
box, press / to switch the values. After setting, press Menu directly
to return to the last interface. Press “ESC” to cancel setting and return to
the last interface.
- 42 -
F18 User Manual V1.0
1:1 Trig: if select “Yes”, when user use 1:1 match mode, alarm signal
will come out. Or there is no alarm signal.
1: N Trig: if select “Yes”, when user use 1: N match mode, alarm signal
will come out. Or there is no alarm signal.
Pwd Trig: If select “Yes”, when user use password verification mode,
alarm signal will come out. Or there is no alarm signal.
Alarm delay: After duress alarm gets started, the alarm signal is not
output directly. But it can be defined. After some time, alarm signal will
be generated automatically.(0-255 seconds) 。
Operation::
Press Menu -> User Management -> Access Setting -> Duress alarm
parameters (as shown below).
Press ▲/▼to move cursor to the item to be set. If it is the input box,
press numeric keys on small keyboard to input the value. If it is the roll
box, press / to switch the values. After setting, press Menu directly
to return to the last interface. Press “ESC” to cancel setting and return to
the last interface.
- 43 -
F18 User Manual V1.0
【overview】
Sometimes, some illegal person follows the employee into the gate,
which will bring security problem. To prevent such risk, this function is
enabled. In record must match out record, or the gate won’t be open.
This function needs two machines to work together. One is installed
inside the door (master machine hereinafter), the other is installed
outside the door (slave machine hereinafter). Same Wigand signal
communication is adopted between the two machines. Same user and
user ID number enrolled。
Operation:
Press Menu -> User Management -> Access Setting -> Anti-Passback
setting (as shown below).
- 44 -
F18 User Manual V1.0
The choice of Machine models: Press ▲/▼ to switch the input box.
Press / to modify the setting. Select Anti-Out, refer to out anti-pass
back, only user’s last record is in-record, the door can be open.
Otherwise it will trigger the alarm signal as illegal access. Select
“None”, refer to no anti-pass back, and no alarm will be triggered. After
setting, press Menu directly to return to the last interface. Press “ESC”
to cancel setting and return to the last interface.
Anti-passback Function:
The master machine control OUT and the slave machine control IN.
In anti-passback (APB-In):
Only user’s last record is out-record, can the door be opened. Otherwise
it will trigger the alarm signal as illegal access.
Enter: New user’s first time access will pass.
In anti-passback mode not restrict of OUT.
Out anti-passback (APB-Out):
Only user’s last record is in-record, the door can be opened. Otherwise it
- 45 -
F18 User Manual V1.0
Machine status:
Press / to move cursor to the item to be set. If select “Control Out”,
the master control out, the other machine control entry. Need two
machines cooperation.
- 46 -
F18 User Manual V1.0
3. Communication Option
When the device and PC are used to transmit data, it is necessary to use
communication wire to set communication parameters in the device.
When the device is in communication, “communicating…” appears.
Don’t operate the device then.
- 47 -
F18 User Manual V1.0
Press ▲/▼to move cursor to the item to be set. If it is the input box,
press numeric keys on small keyboard to input the value. If it is the roll
box, press / to switch the values. After setting, press Menu directly
to return to the last interface. Press “ESC” to cancel setting and return to
the last interface.
- 48 -
F18 User Manual V1.0
485 is recommended.
RS232: Whether use RS232 to communicate. Select “ON” if RS232 is
to be used.
RS485: Whether use RS485 to communicate. Select “ON” if RS485 is
to be used.
USB: Whether use USB to communicate. Select “ON” if USB is to be
used.
RS232, RS485 and USB cannot be used at the same time.
Operation:
Press ▲/▼to move cursor to the item to be set. Press / to switch the
values. After setting, press Menu directly to return to the last interface.
Press “ESC” to cancel setting and return to the last interface.
3.3 Security
- 49 -
F18 User Manual V1.0
- 50 -
F18 User Manual V1.0
- 51 -
F18 User Manual V1.0
Input the name of user-defined format. Press ▲/▼to move cursor to the item
to be set. If it is the input box, press numeric keys on small keyboard to
input the value. If it is the roll box, press / to switch the values.
After setting, press Menu directly to return to the last interface. Press
“ESC” to cancel setting and return to the last interface.
Format: It is the defined format in the system. User need not specify
total digit and the information position.
There are 4 definition formats by default in the system: Wiegand 26 with
site code, Wiegand26 with site code means W26 format output with
device ID. If there is no site code, then the signal not to be output does
not contain the information. If there is site code, the output is the set site
code(similar to device ID. But this code is specified by the user and
different devices can be repeated, with range of 0-255.) .
Failed ID: It is the failed ID after unsuccessful verification. “Close”
means not to output it. (With range of 0-65534)
Site code: Similar to device ID. But the code is specified by user.
Different device can be repeated. (With range of 0-255)
Pulse width: Pulse width is 100 microseconds by default, which can be
adjusted from 20 to 800.
Pulse interval: It is 900 microseconds by default, which can adjusted
between 200 and 20000.
Output content: Content contained in Wiegand output signal, choose
User ID or card number.
Operation:
- 52 -
F18 User Manual V1.0
Input the name of user-defined format. Press ▲/▼to move cursor to the
item to be set. If it is the input box, press numeric keys on small keyboard to
input the value. If it is the roll box, press / to switch the values. For
example, to modify failed ID as 10, press / firstly to select “Yes”, then
input 10 in the input box. After setting, press Menu directly to return to the
last interface. Press “ESC” to cancel setting and return to the last interface.
- 53 -
F18 User Manual V1.0
4. System Option
- 54 -
F18 User Manual V1.0
- 55 -
F18 User Manual V1.0
Press ▲/▼ to move cursor to the input box. Press numeric key on small
keyboard to input the value. If it is the input box, press numeric keys on
small keyboard to input the value. If it is the roll box, press / to
switch the values. After setting, press OK or menu directly to save the
setting and return to the last interface. Press “ESC” to cancel setting and
return to the last interface.
- 56 -
F18 User Manual V1.0
Update the firmware by utilizing the USB Pen Drive (flash drive)
- 57 -
F18 User Manual V1.0
Press ▲/▼ or / to move cursor to the input box. Press numeric key
on small keyboard to input the number. After setting, press menu
directly to save the setting and return to the last interface. Press “ESC”
to cancel setting and return to the last interface.
4.4.1 Verification
There are two clock modes for Select. After verification, the selected
clock mode will be displayed on the screen.
- 58 -
F18 User Manual V1.0
Picture cycle interval means how soon will the picture be changed
(effective value is 3~999 seconds.)
Display propaganda picture: User can display some propaganda pictures on the
screen. The operation refers to this manual 10.4 Propaganda picture upload rules
Time display delay means the clock picture display time length after
verification. After the display delay, the propaganda picture will be
displayed on initial interface again (with effective value of 0~999
seconds, and 0 means displaying clock all along. )
- 59 -
F18 User Manual V1.0
Notice:
"4.4.3 Picture cycle interval" and
"4.4.4 Clock display delay"
functions are fit use common
mode of interface style only.
When you select matrix or magic
mode, these functions are
invalid. Display screen show the
matrix or magic style all the
Common-Style hil
Matrix-Style Magic-Style
4.5 Reset
- 60 -
F18 User Manual V1.0
Set sleep time, external bell and other parameters for the device.
Scheduled sleep: When it is the scheduled sleep time, the device not in
operation will enter sleep status. Press any key or finger to awake it.
External bell: whether to enable external bell (It is the bell ring given
off from external electronic bell, connected with the internal of the
device, instead of the device speaker.
- 61 -
F18 User Manual V1.0
- 62 -
F18 User Manual V1.0
5. Date Time
Press ▲/▼ to move cursor to the input box. Press numeric key on small
keyboard to input the value. After setting, press menu directly to save
the setting and return to the last interface. Press “ESC” to cancel setting
and return to the last interface.
5.2 DLST★
- 63 -
F18 User Manual V1.0
1) Set DLST as “ ON ”.
2) Input DLST start time and end time.
For example, if 08:00, April 1st is set, the device enter DLST, and the
time will be one hour forward. If it is 08:00, August 1st, the device will
reset normal time.
- 64 -
F18 User Manual V1.0
- 65 -
F18 User Manual V1.0
6. PenDrive Management
- 66 -
F18 User Manual V1.0
device ID).
- 67 -
F18 User Manual V1.0
Insert U disk into USB slot of device. Press “▲/▼” to preview the
pictures of U disk. If you want to upload the picture, click OK. Then the
next picture will appear automatically. After upload, press ESC to exit.
- 68 -
F18 User Manual V1.0
7. Auto Test
The device can automatically test TFT color display effect through color
display, white display and black display) to see whether the screen
works normally.
Press OK to continue and press ESC to exit.
The device can automatically test voice prompt effect through playing
voice files in the device to see whether the files are complete and the
voice effect are good or not.
- 69 -
F18 User Manual V1.0
The device can automatically test various keyboards to see whether the
keys work normally or not.
Press any keyboard on the test interface (except for OK and ESC) to
check whether the pressed keyboard is in accordance with that displayed
on the screen.
Will appear whether it is the right key, and will appear whether
it is not the right key.
Press ESC to exit.
The device will automatically test the sensor to see whether it works
normally. Press fingerprint to see whether the image is clear and usable.
Press fingerprint on the sensor window and the fingerprint image will
appear on the screen.
Press ESC to exit.
The device can automatically test the clock to see whether it works
normally.
Press OK to start time and then press OK to stop time.
Press ESC to exit.
- 70 -
F18 User Manual V1.0
8. Query Record
Notice: The picture may be different from your device. The real
product prevails.
- 71 -
F18 User Manual V1.0
Press “▲/▼” to move the cursor to the line to be queried. And press OK
to check attendance record.
For example, the detailed attendance information of employee 10001 on
May8th as follows:
At the bottom of the screen, there are some remark, and the capital
letters with their meanings:
Verification:
F: means Fingerprint verification
P: means Password verification
C: means ID card verification
Status:
It is the attendance status. The code displayed in the list is the status
code. And status name will be displayed in the information column.
- 72 -
F18 User Manual V1.0
9. System Information
Use system information to check the current device’s saving status, its
version information and so on.
- 74 -
F18 User Manual V1.0
10. Appendix
10.1 Keyboard
Different device has different kinds of keyboard, and the function of the
keyboard is different. Please check the fallows:
Keyboard type 1:
key function
Numeric 1. 0~9 , used to input employee number, password and so
key on.
2. 0 on manage user interface is shortcut of “query user”.
▲ 1. Upward.
2. Status key.
▼ 1. Downward.
2. Status key.
1. Modify current item value.
2. Status key.
/ 1. Power-off. Press it on initial interface for 3 seconds to
enter power-off count down state.
2. Space back. Press it when User ID, password and system
value are input incorrectly to delete the wrong value and
input the value again.
3. Status key.
M/OK Menu, OK
ESC 1. Cancel the operation and return to the superior menu
2. Press ESC on initial interface to display the keyboard
definition of the present device.
- 76 -
F18 User Manual V1.0
Keyboard type 2:
key function
Numeric 1. 0~9,used to input employee number, password and so
key on.
2. 0 on manage user interface is shortcut of “query user”.
▲ 1. Upward.
2. Shortcut.
▼ 1. Downward.
2. Shortcut.
*/ 1. Modify current item value.
2. Shortcut.
3. Enable T9 input.
4. Switch input method in T9 input.
/ 1. Modify current item value.
2. Space back. Press it when User ID, password, and
system value are input incorrectly to delete the wrong value
and input the value again.
3. Shortcut.
0/ 1. power-off. Press it on initial interface for 3 seconds to
enter power-off count down state.
2. Shortcut.
M/OK Menu, OK
ESC 1. Cancel the operation and return to the superior menu.
2. Close T9 input.
- 77 -
F18 User Manual V1.0
Keyboard type 3:
key function
Numeric 1. 0~9,used to input employee number, password and so
key on.
2. 0 on manage user interface is shortcut of “query user”.
▲ 1. Upward.
2. Shortcut.
▼ 1. Downward.
2. Shortcut.
1. Right.
2. Shortcut.
1. Left.
2. Shortcut.
/ 1. Shutdown. In the initial interface press this key for 3
seconds to enter a shutdown countdown status.
2. Space back. Press it when User ID, password, and
system value are input incorrectly to delete the wrong value
and input the value again.
MENU Menu, OK, after verification press this key to inquire
records。
OK OK
N/A Invalid key( Access machine do not have this key)
F1 Sign in state key.
F2 Sign out state key.
Doorbell key(Access machine have this key)
ESC Cancel the operation and return to the superior menu.
- 78 -
F18 User Manual V1.0
10.2 USB
USB Host
The device will may be used as USB Host to exchange data with
external U disk.
The data transmission speed is quick, the traditional fingerprint machine
only supports the RS232, RS485 or Ethernet way data transmission,
when as a result of physical condition limit, data quantity big, and the
data transmission cost quite long time. But the USB data transmission is
more quick than the former any transmission mode, may complete
downloading data by U disk in a short period of time, like this greatly
enhances the efficiency.
The operational steps of the device as USB Host please refer to the
manual "6. PenDrive management" detailed briefing.
USB Client★
The device will be as removable storage devices and the data in the
device will transfer to a PC via connected USB cable.
When the device is an USB Client, the Communication Option will have
USB communication options. For more details please refer to the
manual “3. Communication Option”.
It is used for common user to query his intraday attendance record to see
whether there is something wrong for attendance time and notify
administrator the abnormal recorder in time.
Operations:
Press to display the employee’s intraday records after successful
- 79 -
F18 User Manual V1.0
Notice: The picture may be different from your device. The real
product prevails.
The picture format must be JPG. Other formats are not accepted here.
The file name of propaganda picture must be ad_0~ad_9, for example
ad_1.Jpg.
The file name won’t be changed after it is uploaded to the device. If it is
necessary to change this picture, upload another picture with the same
file name to cover it.
Every picture cannot be over 30K, or it cannot be uploaded.
- 80 -
F18 User Manual V1.0
The picture’s resolution is 320 wide and 240 high. It is better not to be
more or less than it.
The propaganda pictures’ count should be 10 at most.
If you want it, please contact our businessman or technician.
- 81 -
F18 User Manual V1.0
Summary
The T & A system is based on Web Server technical, use Page Request
technical to process and manage data, it integrate many feature ,such
local data collection , intellectualized port (RS232/RS485),
communication protocol conversion, image collection, alarm data stored
up , and WEB server etc. basing on this equipment to create an unifying
monitoring platform that supply one solution for equipment
management, Time &Attendance, as well as monitor, in addition the
Web Time & Attendance solution is independent on regional limit, and
do not need to install other software. utilize IE or Netscape browser,
downloading and remote on-line management, handle time sheet
corrections and create report table on the fingerprint terminal is
available , it supply easy way for manager of enterprise know the
employ in post or attendance state at any moment, in time search for
information, statistic data, deal with operation at same time, provide a
solution of staff attendance , check in or out management, pay roll
management, in word and deed realize that at everywhere any moment
the information is synchronization, its go far beyond traditional Time &
Attendance solution.
Why does embedded Web Server into the device?
1. a few or nobody keep watch
Thought TCP/IP and Ethernet, WEB Server is able to reliable apply to
local network, the data fingerprint machine store up can be watch and
deal via long distance network , with browser it is not need to
administrator or person specially assigned go to local for to achieve task
collect data, upload and download data, as well as upgrade system, , not
have other software and tools
- 82 -
F18 User Manual V1.0
Some device provides correct and current time in any world time period,
country or major city. Accurate adjustments for Daylight Saving Time
(or Summer Time) are made according to each location's rules and laws.
No matter what time period a country or city is located in, this is your
top choice for a clock resource site.
- 83 -
F18 User Manual V1.0
This function can be set in the fingerprint machine option, Press Manu
key, enter the Date Time. In the XX Month XX Date XX minute move
forward an hour, and that in the XX Month XX Date, XX Minute move
Back an hour.
The operation refers to this manual 5.2 DLST.
Overview
In order to reduce the repeated enrollment operation in multiple devices,
we can use the master-slave option. It only needs to enroll user
information in one master device; other slave units will send
synchronization requests to the master according to set master-slave
parameters. The master unit sends its all user information and
fingerprint template data to slave units when it has checked a
synchronization request on the network. Slave units receive and save the
data from master. So the user enrolled in the master unit may record
attendance in multiple slave units.
Operation
1) Menu setup
Enter "Menu - Communication option - Master-slave option", there
are four relevant options:
Master unit: Whether set this device to be a master unit. Select “Y” if
you want to.
Slave unit: Whether set this device to be a slave unit. Select “Y” if you
want to.
Master Server IP: Input the master server IP manually if you set this
device as a slave unit.
Sync Each hour: The synchronization frequency after the connection --
- 84 -
F18 User Manual V1.0
You can set every few hours to synchronize. (With range of 0-99, only
the device is set as master unit, this setting is valid)
2) Connection
Choose the master unit and slave unit. Connect them to the LAN
through the switch.
Restart the devices after connection. The master unit is an ordinary
fingerprint device. After the device restarted, slave unit will
automatically search the master unit and send a request.
If the message “Fail to sync” shown on the slave unit, it means the slave
unit can’t found the master unit, and the data update is failed. Please
check the settings through the device menu.
If there is no prompt in the client, which means the connection is
successful. The process in the master unit is same to the ordinary
fingerprint device. The data in the master unit will be synchronized to
the slave units according to the parameters set in master slave option.
- 85 -
#24,Shambavi Building, 23rd Main,Marenahalli,
JP Nagar 2nd Phase, Bangalore - 560078
Phone: 91-8026090500 | Email : [email protected]
www.esslsecurity.com