0% found this document useful (0 votes)
43 views1 page

Madhepura - Sf-Ele

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views1 page

Madhepura - Sf-Ele

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

G

H
A

J
I
7

7
W W W
AC POINT AC POINT AC POINT AC POINT
Computer Computer

D3 D3

Computer
Assistant I.T. Manager
(13'-3'' X 10'-6'')
Kitchen
D3 D3

Computer
(10'-0'' X 12'-0'')
AC POINT

Meeting Hall

Computer
(26'-9'' X 18'-4'')
Dinning D3
(21'-11'' X 27'-3'')
6

6
D2 D2
D2

Computer
Computer
(5'-0'' X 6'-0'')
D2

AC POINT
D2

Computer
AC POINT

(13'-3'' X 10'-6'')

D2
5

5
Computer Computer

D1 Computer Computer

D1
Lobby
(38'-3'' X 15'-6'') Civil Circle

AC POINT
D1
Work Station (13'-3'' X 10'-6'')

Computer

Computer

Computer

Computer

Computer
(40'-0'' X 24'-0'')
4

4
Superintending Engineer

Computer

Computer

Computer

Computer

Computer
(13'-3'' X 10'-6'')

Computer
Computer

Computer

Computer

Computer

Computer
Record Room
(32'-4'' X 31'-2'')
AC POINT AC POINT AC POINT AC POINT

REFERENCE
3

3
QTY. HEIGHT
BATTEN HOLDER POINT 05 NOS. 2400 MM FROM FFL
TUBE LIGHT POINT 04 NOS. 2400 MM FROM FFL
CEILING FAN POINT 39 NOS. CEILING
POWER POINT 26 NOS. 450 MM TO 600 MM FROM FFL
SWITCH BOAR WITH SOKET 20 NOS. 1200 MM FROM FFL
5A SOCKET POINT EXTRA 12 NOS. 450 MM TO 600 MM FROM FFL
5A SOCKET MULTI POINT 07 NOS. 750 MM TO 900 MM FFL
2

2
EXHAUST FAN POINT 05 NOS. 2400 MM FROM FFL
CALL BELL POINT 05 NOS. 2400 MM FROM FFL
IN INTERNET OUTLET 28 NOS. 750 MM TO 900 MM FFL
W
TL TELEPHONE JACK 13 NOS. 750 MM TO 900 MM FFL
AC POINT
AC POINT 12 NOS. 900 MM TO 1200MM FROM FFL
4 way
TPN DB
4/6 WAY TPN MCB DB 08 NOS. 1800 MM FROM FFL
1'x1' LED LIGHT POINT 42 NOS. CEILING
2'x2' LED LIGHT POINT 50 NOS. CEILING
LED DOWN LIGHT POINT 21 NOS. CEILING
1

1
Computer COMPUTER POINT 28 NOS. 750 MM TO 900 MM FFL
MIRROR LIGHT POINT 04 NOS. 1300 MM TO 1500MM FROM FFL

SECOND FLOOR PLAN 2X1.5 + 1X1.5 SQ.MM WIRE


2X2.5 + 1X2.5 SQ.MM WIRE
LIGHT/FAN POINT TO SWITCH BOARD

COMPUTER/MULTI POINT TO DB
2X4 + 1X4 SQ.MM WIRE AC/POWER POINT TO DB
T HI S D RA WING IS T HE P ROP ER TY & NOTE :--
NORTH COPYRIGHT OF M/S SPACE ACE & NO 1. DO NOT SCALE THE DRAWING, FOLLOW WRITTEN DIMENSION ONLY. REVISIONS-01 DRAWN BY - PROJECT TITLE SHEET TITLE CLIENT SHEET NO.
2. ALL DIMENSIONS IN FT.
E PART OF THIS DRAWING MAY BE USED
DATE - 22.05.2023 SPACE ACE
OR REPRODUCED IN ANY MANNER,
STORED IN A RETRIEVAL SYSTEM, OR
3. 450-750 WIDE PLINTH PROTECTION TO BE PROVIDED ALL AROUND THE
BUILDING. CONSTRUCTION OF NEW BUILDING FOR BIHAR STATE POWER ARCHITECTS, ENGINEERS & PLANNERS
4. SKIRTING SHALL BE 100MM. HIGH FROM FINISHED FLOOR LEVEL. SCALE -A/3-NTS
SECOND FLOOR
03
TRANSMITTED IN ANY FORM OR BY ANY
N S ME ANS, ELE CTRONIC , MECHA NICAL,
5. TOILET,PANTRY, KITCHEN VERANDAH & BALCONY FLOOR LEVEL SHALL
BE 12 MM. DOWN FROM GENERAL FLOOR LEVEL. DRG. NO. -BP/ELEC/SF/03
TRANSMISSION CIRCLE OFFICE TRANSMISSION COMPANY V - 20A / 5 ,
PHOTOCOPYING, RECORDING OR D.L.F. CITY III,
OTHERWISE, EXCEPT FOR THE
6. CUPBOARDS SHALL HAVE SKIRTING OF 100 MM. HIGH.
7. LOCATION, SIZES & LEVELS OF MANHOLES TO BE CO-ORDINATED WITH CHECKED BY - BUILDING (G+2) AT MADHEPURA, BIHAR PLAN GURGAON, HARYANA - 122002

W
R ELA TE D PR OJEC T, WI TH OUT THE
WRITTEN PERMISSION OF M/S SPACE
EXTERNAL SEWERAGE LAY OUT PLAN GOT APPROVED BY ENGG.
INCHARGE.
LIMITED, PATNA, BIHAR PH - 0124-4106618,FAX: 0124-2365329
E-MAIL : [email protected]
A C E . 8. ALL MEASUREMENT MUST BE CHECKED AT SITE BY CONTRACTOR.
G
C

H
A

J
I

You might also like