E³.

cable
Warning and Error Messages
Technical Inquiries
Please contact our Support Department!
E-Mail: [email protected]

Note:
Zuken is not responsible for any errors which may appear in this documentation. Liability, due
to direct and indirect losses resulting from the delivery or use of this documentation, is
excluded to the extent permitted by law. This documentation contains copyrighted information.
All rights, especially those pertaining to the duplication and distribution as well as the
translation, are reserved. This documentation, whether wholly or in part, may not be
reproduced in any form (photocopy, microfilm, etc.), or processed, duplicated, or distributed
using an electronic system without Zuken’s prior written consent.

Contact
Zuken E3 GmbH
Lämmerweg 55
D-89079 Ulm/Einsingen

Phone: +49 7305/9309-0


Fax: +49 7305/9309-99
Web: http://www.zuken.com
E-Mail: [email protected]

© Copyright 2023, Zuken E3 GmbH


Contents

Contents
1 Introduction........................................................................................................................ 1
2 Warning Messages in E3.cable ............................................................................................. 1
3 Error Messages in E3.cable .................................................................................................. 3

I
Introduction

1 Introduction
When working with E3.cable and saving projects in the format .e3sx, warning and error
messages are shown to inform you about objects that are not supported or only have a limited
functionality.

This documentation gives an overview of the messages, the causes for the messages and how
to resolve the corresponding warning or error.

2 Warning Messages in E3.cable


When warning messages occur, the project can be saved in the format .e3sx but data of the
project will be lost in the .e3sx file. This is due to some objects and functionalities not being
supported in the current version of E3.cable. The following dialog opens:

The following table lists the objects that cannot be transferred to the .e3sx file, the warning
messages that are shown in the output window of E3.cable, and a solution to prevent the data
loss.

Unsupported object Warning Message Solution

Grouped Objects Sheet content on <sheet Ungroup the reported objects.


name> Group <group
name> at position
<x>/<y> [Jump]

Grouped Sheets Grouped elements <group Ungroup the reported sheets.


name> [Jump]

Unplaced Groups Unplaced groups <group Place or delete the reported


name> [Jump] unplaced groups.

1
Warning Messages in E3.cable

Connection with Sheet content on <sheet Assign the same option to all
Different Options on name> connect lines of the connection.
Connect Lines Connection with
different options at
position <x>/<y> [Jump]

Table Configurations Table configuration No solution available.


<table name> The project will be saved with no
need to confirm.

Signal Structure Signal structure No solution available.


Confirm the dialog Save anyway
with Yes.

Attribute Texts and Attribute texts and Delete the reported attribute
Graphic Representation graphical representation.
of the Object on representation of owner
Different Sheets on different sheets
<attribute
name>=<attribute value>
from connection on
sheet <sheet name> at
position <x>/<y> [Jump]
on sheet <sheet
name> at position
<x>/<y> [Jump]

2
Error Messages in E3.cable

3 Error Messages in E3.cable

When error messages occur, the project cannot be saved in the format .e3sx because the
project contains data inconsistencies or data that is not supported in the current version
ofE3.cable. One of the following two dialogs open:

The following table lists the error source, the error messages that are shown in the output
window of E3.cable, and a solution to save the project in the format .e3sx.

Error Source Error Message Solution

Data inconsistencies E - The project cannot Save the project in the format
be saved as project .e3s and contact your local E3
file because it support team.
contains consistency
errors.

Clipboards Clipboards Clipboard Merge the contents of the


[<username>] [<date> clipboard to the project or delete
<time>] [Jump] the clipboard.

Missing Related Non-existent symbol Complete the following steps:


Symbols Referenced by <symbol name>, 1. Load the missing symbol
a Component referenced by from the library:
Component 2. Place the symbol on a
<component name>
sheet.
3. Delete the newly loaded
symbol from the sheet.

Missing Related Non-existent symbol Complete the following steps:


Symbols Referenced by <symbol name>, 1. Load the missing symbol
a Device referenced by from the library:
<device name> 2. Place the symbol on a
sheet.
3. Delete the newly loaded
symbol from the sheet.

Missing Related Non-existent symbol Complete the following steps:


Symbols Referenced by <symbol name>, 1. Load the missing symbol
an Attribute referenced by from the library:
Attribute 2. Place the symbol on a
<attribute name> of sheet.
component <component
3. Delete the newly loaded
name> [Jump]
symbol from the sheet.

3
Error Messages in E3.cable

Missing Related Non-existent symbol Complete the following steps:


Symbols Referenced by <symbol name>, 1. Load the missing symbol
a Setting referenced by from the library:
Setting <setting> 2. Place the symbol on a
sheet.
3. Delete the newly loaded
symbol from the sheet.

Hierarchical Connectors Hierarchy interface Dissolve the assembly.


in Assemblies connectors as part of
an assembly
<device name>
[Jump]
<device name>
[Jump]

Connector with E - The project cannot Assign a valid connector


Dynamic Component be saved as project component to the connector.
file because it
contains consistency
errors.

Setting Show Setting 'Show Deactivate the setting Show


information for option information for option information for option
combinations is combinations' is not combinations.
Activated permitted if the
project is to be saved
as a project file

4
Europe
Germany
Zuken GmbH (European HQ)
D-85399 Hallbergmoos, Germany
Tel: +49 89 7104059 00

Americas Zuken E3 GmbH


D-89079 Ulm, Germany
North America
Tel: +49 7305 9309 0
Zuken USA Inc.
Westford, MA 01886, USA
Tel: +1 978 692 4900 Zuken E3 GmbH
D-30659 Hannover, Germany
Tel: +49 511 8595 9489
Asia
Japan Switzerland
Zuken (Worldwide Head Office) Zuken E3 GmbH
Yokohama, Kanagawa 224-8585, Japan CH-5504 Othmarsingen, Switzerland
Tel: +81 45 942 1511 Tel: +41 62 561 08 00

China United Kingdom


Zuken (Shanghai) Technical Center Co., Zuken UK Ltd.
Ltd. Bristol, BS32 4RF, UK
Room 301, No.555 Nanjing West Road, Tel: +44 1454 207 801
Shanghai, 200041, People's Republic of
China
Tel: +86-21-3218-1784 France
Zuken S.A.
Korea #91974 Les Ulis Cédex, France
Zuken Korea Inc. Tel: +33 1 69 29 48 00
Seoul 135-283, Korea
Tel: +82 2 5648031 Italy
Zuken S.r.l.
Singapore 20090 Milanofiori Assago, Milan, Italy
Zuken Singapore Pte Ltd. Tel: +39 02 575 921
#22-05 Gateway East, Singapore 189721
Tel: +65 6392 5855 Netherlands
Zuken GmbH
Taiwan NL-6075 HA Herkenbosch, The Netherlands
Zuken Taiwan Inc. Tel: +31 475 520 998
Taipei 110, Taiwan
Tel: +886 2 7718 1116

www.zuken.com/e3
All trademarks mentioned are the property of their respective owners, Copyright © Zuken E3 GmbH

You might also like