Thermostat Manual-Jumo
Thermostat Manual-Jumo
JUMO heatTHERM
Panel-mounted thermostat
Special features
• Stable switching point position due to ambient temperature compensation (standard)
• Max. switching capacity 16 A, 400 V
• Operating life at least 250,000 switching cycles for TR and TW
• Control ranges of upt to 500 °C are possible
• STB with extensive setting range: 250 K at 250° (angular degree)
• Switching point deviation during the entire operating life of up to ±5 %
Type 602030/01
Brief description
Thermostats control and monitor thermal processes.
This thermostat is available as temperature controller TR, temperature monitor TW (type
602030), safety temperature monitor STW (STB), or safety temperature limiter STB (type
602031).
The panel-mounted thermostat operates according to the fluid expansion principle. The electrical
switching element is a snap-action switch.
The panel-mounted thermostat is RoHS-compliant and cadmium-free.
Type 602030/02
Switching functions
Temperature controller TR and Temperature monitor TW
If the temperature on the temperature probe exceeds the setpoint value, the electrical circuit is
opened or closed by a microswitch. If the temperature falls below the selected setpoint value (by
the switching differential), the microswitch is reset to its initial position.
Restart lock at safety temperature limiter STB
If the temperature at the temperature sensor exceeds the set limit value, the electrical circuit is
opened and the microswitch is mechanically locked. After falling below the limit value by approx.
10 % of the temperature range (approx. 15 % of the limit value setting > +350 °C), the switch can
be unlocked manually. Type 602031/20, Type 602031/21
Use of the safety temperature monitor STW as a safety temperature limiter STB
The circuitry used with the thermostat must comply with DIN EN 14597 and VDE 0631.
Self-monitoring for safety temperature limiter STB and safety temperature monitor STW
(STB)
If the measuring system is destroyed (i.e. if the expansion fluid escapes) the pressure in the
membrane of the STB and STW (STB) drops and permanently opens the electrical circuit. Un-
locking is then no longer possible.
When the STW (STB) and STB sensors cools down to the negative temperature range, the cir-
cuit 1 to 2 opens, but must be unlocked manually by the restart knob when the temperature rises.
The STW (STB) restarts automatically.
Type 602031/80, Type 602031/81
PED
Pressure
Equipment
Directive
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
Technical data
Electrical data
Switching element Snap-action switch with single-pole changeover contact
Max. switching capacity TW/TR STW (STB) STB
On the N/C contact AC 400 V +10 %, 16 A, AC 230 V +10 %, 16 (2.5)a A, cos = 1 (0.6)a,
(contact deck 1 to 2) DC 230 V +10 %, 0.25 A
On the N/O contact AC 400 V +10 %, 6.3 A, -
(contact deck 1 to 4) a
AC 230 V +10 %, 6.3 (2,5) A, cos = 1 (0.6) , a
Environmental influences
Switching differential in % Rated value
of the control/limit value range
TR, TW 2.5 (Standard)
7 (auf Anfrage)
STW (STB) 7 (Standard)
Switching point accuracy in %
of the control/limit value range
TR, TW In the upper third of the scale ±3 %, at the beginning of scale ±6 %
STW (STB), STB In the upper third of the scale ±4 %, at the beginning of scale ±8 %
Control range In the „first half“ In the „second half“
70 to 130 °C +0/-12 K +0/-5 K
95 to 120 °C +0/-5 K +0/-5 K
20 to 150 °C +0/-15 K +0/-10 K
50 to 300 °C +0/-30 K +0/-15 K
Ambient temperature influence Referring to the control/limit value range
If the ambient temperature at the switching head and/or the capillary deviates from the calibration
ambient temperature 22 °C, a switching point shift occurs.
Admissible storage temperature -50 to +50 °C or up to max. admissible ambiente temperature, see nameplate
Admissible ambiente temperature See nameplate
when in use
Rated position (NL) Any
Housing
Material
Housing Sheet steel, galvanized
Capillary Cu-DHP
Swtiching socket Polyester resin molding compound, white
Protection type IP00, according to DIN EN 60529
Weight Approx. 120 g
Capillary 2000 mm (standard) inclusive 460 mm protective tubing
Min. bending radius 5 mm
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
Dimensions
Type 602030/01
• Temperature controller 21
• Compensated ambient temperature
(standard)
19
• Max. switching capacity 16 A, 400 V
• Operating life at least 250,000 switch-
ing cycles
• Switching point deviation (drift) during
the entire operating life of up to ±5 %
46
~3
460 mm
42
34
2000 mm
L
Ø6
250°
36
28
Ød
Ø 1,25
M4
4,6
Type 602030/02
• Temperature monitor 21
• Compensated ambient temperature
(standard)
• Max. switching capacity 16 A, 400 V
• Operating life at least 250,000 switch-
46
ing cycles
34
~3
460 mm
42 34
M4
2000 mm
L
28
36
Ød
Ø 1,25
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
Type 602031/21
• Safety temperature monitor
Ø1,25
• Compensated ambient temperature
Ød
(standard)
• Max. switching capacity 16 A, 400 V L
2000mm
15
460
46
34
42 ~3
34
M4
28
36
Type 602031/80
• Safety temperature limiter
Ø 1,25
2000 mm Ød
15
460 mm
39
34
1,7
~3
16,5
13
M 10 x1
17
42
10
34
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
Type 602031/81
• Safety temperature limiter
Ø 1,25
L
• Compensated ambient temperature
Ød
(standard)
• Max. switching capacity 16 A, 400 V
2000mm
15
460
42,8
34
1,7
~3
16,5
M 10 x1 13
17
42
10
?
34
+95...120 78°<
+70...130 167°<
RB (°C) ?
Type 602031/81
• Safety temperature limiter
• Compensated ambient temperature 0°
(standard) 25
• Max. switching capacity 16 A, 400 V
• With extra code 749: 250° (angular de-
gree)
34
42
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
Connection diagram
The connection diagram in the data sheet provides information on product selection.
For the electrical connection, only use the installation instructions or the operating manual.
Wiring diagrams
1
1
2 4
2 4
TW
TR
Type 602031/20 and Type 602031/21 Type 602031/80 and Type 602031/81
1
1
2 4
2 4
STB
STW
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
Order details
(1) Basic type
602030/01 JUMO heatTHERM – Panel-mounted thermostats, temperature controller (TR)
602030/02 JUMO heatTHERM – Panel-mounted thermostats, temperature monitor (TW)
602031/20 JUMO heatTHERM – Panel-mounted thermostats, safety temperature monitor (STW), permanently set
602031/21 JUMO heatTHERM – Panel-mounted thermostats, safety temperature monitor (STW)
602031/80 JUMO heatTHERM – Panel-mounted thermostats, safety temperature limiter (STB), permanently set
602031/81 JUMO heatTHERM – Panel-mounted thermostats, safety temperature limiter (STB)
(2) Basic type extensions
000 With permanently set limit value
026 0 to 120 °C
028 0 to 200 °C
041 20 to 90 °C
043 20 to 150 °C
064 50 to 300 °C
640 50 to 300 °C (S)
666 60 to 130 °C
671 60 to 130 °C
(3) Limit value (STW/STB)
000 With adjustable control range
095 95 °C
100 100 °C
110 110 °C
(4) Switching differential
00 None
25 2.5 %
70 7%
(5) Capillary length
1000 1,000 mm
2000 2,000 mm
3000 3,000 mm
(6) Capillary material
40 Cu (copper), Ø 1.25 mm
(7) Process connection
10 Plain cylindrical probe
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
Stock versions
JUMO heatTHERM – Temperature controller (TR) with 2,000 mm capillary and probe diamter 6 mm
Order code Control range Limit value Switching differ- Part no.
ential
602030/01-041-000-25-2000-40-10-6-40-13-460/707 20 to 90 °C With adjustable Approx. 2 K 60003218
602030/01-041-000-70-2000-40-10-6-40-13-460/707 20 to 90 °C control range Approx. 5 K 60003280
602030/01-026-000-25-2000-40-10-6-40-13-460/707 0 to 120 °C Approx. 3 K 60003219
602030/01-028-000-25-2000-40-10-6-40-13-460/707 0 to 200 °C Approx. 5 K 60003220
602030/01-064-000-25-2000-40-10-6-40-13-460/707 50 to 300 °C Approx. 6 K 60003221
JUMO heatTHERM – Temperature monitor (TW) with 2,000 mm capillary and probe diamter 6 mm
Order code Control range Limit value Switching differ- Part no.
ential
602030/02-041-000-25-2000-40-10-6-40-13-460/707 20 to 90 °C With adjustable Approx. 2 K 60003222
602030/02-041-000-70-2000-40-10-6-40-13-460/707 20 to 90 °C control range Approx. 5 K 60003281
602030/02-026-000-25-2000-40-10-6-40-13-460/707 0 to 120 °C Approx. 3 K 60003223
602030/02-028-000-25-2000-40-10-6-40-13-460/707 0 to 200 °C Approx. 5 K 60003224
602030/02-064-000-25-2000-40-10-6-40-13-460/707 50 to 300 °C Approx. 6 K 60003225
JUMO heatTHERM – Safety temperature monitor (STW) with 2,000 mm capillary and probe diamter 6 mm
Order code Control range Limit value Switching differ- Part no.
ential
602031/21-671-000-70-2000-40-10-6-40-13-460/707 70 bis 130 °C With adjustable Approx. 10 K 60003226
control range
JUMO heatTHERM – Safety temperature limiter (STB), permanently set, with 2,000 mm capillary and probe diamter 6 mm
Order code Control range Limit value Switching differ- Part no.
ential
602031/80-000-100-00-2000-40-10-6-40-13-460/707 Limit value per- 100 °C Approx. 10 K 60002994
manently set
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
JUMO heatTHERM – Safety temperature limiter (STB) with 2,000 mm capillary and probe diamter 6 mm
Order code Control range Limit value Switching differ- Part no.
ential
602031/81-666-000-00-2000-40-10-6-40-13-460/707 95 to 120 °C With adjustable Approx. 10 K 60002995
602031/81-671-000-00-2000-40-10-6-40-13-460/707 70 to 130 °C control range 60003136
602031/81-043-000-00-2000-40-10-6-40-13-460/707, 20 to 150 °C In the upper third 60003291
749 approx. 15 K
At the scale
beginning
approx. 30 K
602031/81-640-000-00-2000-40-10-6-20-13-460/707, 50 to 300 °C (S) In the upper third 60003292
749 approx. 25 K
At the scale
beginning
approx. 45 K
Accessories
according to product groups 606710 and 606715
Thermowell set
(according to product group 606710), suitable for type 602030 and type 602031
Thermowell with sealing collar Clamp for Plate for surface- Screw for surface-
strain relief mounted thermostat mounted thermostat
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6724 Joy Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex, CM20 2DY, UK Phone: +1 315 437 5866
Phone: +49 661 6003-0 Phone: +44 1279 63 55 33 Fax: +1 315 437 5860
Fax: +49 661 6003-607 Fax: +44 1279 62 50 29 Email: [email protected]
Email: [email protected] Email: [email protected] Internet: www.jumousa.com
Internet: www.jumo.net Internet: www.jumo.co.uk
Setpoint adjuster
(according to product group 606715), suitable for type 602031/01
Type Control range Rotary knob 07 Panel 23 Adjustable stop 16 2 Screws Part no.
in °C
W8 20 to 90 M4 × 8 60003091
0 to 120 60003227
0 to 200 60003095
50 to 300 60003098
V4.00/EN/00415410/2022-03-15 60203100T10Z002K000