Digital Motor Protection Relay Catalog
Digital Motor Protection Relay Catalog
REPM DIGITAL
Series Meta - MEC
Digital
Motor Protection Relay
General digital type motor protection relays using MCU(Micro Controller Unit)
-Real time processing and high precision
Multiple protection
Protection DMP�-S DMP�-SZ DMP�-SI DMP�-SE DMP�-SEZ DMP�-SEI DMP�-T DMP�-TZ DMP�-TI DMP�-TE DMP�-TEZ DMP�-TEI
Wiring Screw type Tunnel type
Panel mount Unit type Extension type Unit type Extension type
Over current
Under current
Stsll
Lock
Phase failure
Revers phase
Asymmetry
Grount fault
Short circuit
Elegant design
High class product image
by the elegant design
3
Specifications of D-EMPR
Digital E M P R
Model No. DMP06-S DMP60-S DMP06-T DMP60-T DMP06-SE DMP60-SE DMP06-TE DMP60-TE
Wiring Screw type Tunnel type Screw type Tunnel type
Panel mount Unit Extension(Note1)
Operation time Select either reverse time characteristics or definate time characteristics
Protection Over current According to the setting time
Phase failure 3 sec.
Reverse phase Within 0.1 sec.
Asymmetry 5 sec.
Stall 5 sec.
Lock Within 0.5 sec.
Under current 3 sec.
Ground fault Within 0.05~1 sec. Selectable (0.05~1.0sec)
Short circuit (Note2) Within 50ms
Alarm Variable (60~110% of the setting current)
Current setting range (A) 0.5�6 5�60 0.5�6 5�60 0.5�6 5�60 0.5�6 5�60
Motor capacity 220�240V 0.09�0.75 1.1�11 0.09�0.75 1.1�11 0.09�0.75 1.1�11 0.09�0.75 1.1�11
(kW) 380�440V 0.12�1.5 2.2�22 0.09�1.5 2.2�22 0.09�1.5 2.2�22 0.09�1.5 2.2�22
Time setting Definate Delay in starting 0�60sec
range (sec) time Delay in operating 0�30sec
Inverse time 0�60sec
Reset Manual reset
Tolerance Current ±5%
Time ±5%(or ±0.5sec)
Operating power (Note3) Voltage AC 190~250V
Frequency 60Hz (50Hz)
Aux. contact OL 2-SPST 3A/250Vac Resistive load
AL SPST 3A/250Vac Resistive load
Insulation resistance Over DC 500V 100㏁
Surge impulse voltage(IEC1000-4-5) 1.2×50㎲ 6kV (Apply standard wave form)
Fast transient burst(IEC1000-4-4) 2.5kV/5min
Environment Temperature Operation -25�70℃
Storage -30�80℃
Humidity 30�90% RH (No freezing)
Display 7-Segment 3 phase current, cause of a fault
Bar-Graph 60�110% of real load current
Mounting type 35mm Din-rail/Panel
Note1) In extension type, the digital EMPR is calibrated with combining the display past and mainbody so, please cautious not to
combine the display part and main body with different part No.
Note2) Instantaneous short circuit protection is optional
Note3) Operational voltage of AC 110V and 50Hz is optional
4
Setting M e t a - M E C S E R I E S
Digital E M P R
2. Shift the mode by pressing the FUNC key and then select the values by press the Sel key
� You can finish the setting by pressing the Sel key in the Sto mode
� To protect the operation under the motor rotating, setting is allowed only in the test mode
FUNC Sel Functions Note
Inverse or definite time Default is inverse time
characteristics characteristics
Set the O-time For D-time setting,
(Definite time only) use the time knod
Reverse phasse protection Default is ”Off”
Note2)
CT ratio Default is 1:1
Store
5
Setting
Digital E M P R
6
M e t a - M E C S E R I E S
Normal condition
5A setting
Turn on
Overload
ex)
Under current Reverse phase
Turn
on& off
Lock
7
Dimensions
Digital E M P R
DMP�-S
DMP�-SZ
DMP�-SE
DMP�-SEZ
Panel mounting
DMP�-T
DMP�-TZ
DMP�-TE
DMP�-TEZ
Panel mounting
DMP-S/SE/ T / TE
Over-current/Under current/Phase failure/Asymmetry
Stall/Lock/Instantaneous short circuit protection
�Unit type or extension type is available
- Extension type:Remotely mounts the display unit
on the panel surface
�3 phase ampere meter function:Check the 3 phase
current and setting value by press the display button
�Select the inverse time or definite time
�Easy to operate:Set the most function by the operation
button and knod
�Display the causes of the fault and the values
�Alarm setting:Load ratio is displayed up to setting current
�Instantaneous current function is option
Protect function
Over current Depend on setting time Selectable the inverse/definite
Phase loss Within 3seconds Over 70% of the rate of unbalance
Phase unbalance Within 5seconds Over 50% of the rate of unbalance
Phase reverse Within 0.1seconds Function enable
Stall Within 5seconds Over 180% of the setting current
Lock Within 0.5seconds Setting 200~900% of rated current
Under current Within 3seconds Setting 30~70% of rated current
Instantaneous current (Note1) Within 50seconds Setting 300~1800% of rated current
☞ Lock protection is operated after setting D-time in case of definite time type
Function selection
FUNC Sel Description
1. CHA Inv/dEF Operating characteristics setting(Inverse/definite time type)
2. dEF 0�30(S) Setting the operating time(In definite type)
3. r.P oFF/on Phase reverse enable
4. Und oFF/30�70(%) Under current enable and setting
5 . A lt oFF/60�110(%) Alerting enable and setting
6. S t l oFF/on Stall enable
7. Loc oFF/200�900(%) Lock enable and setting
8. Ct 1�120 CT ratio setting
9. P.F on/oFF Phase fault enable
Sto Sto Store
☞ 2.dEF is only displayed when dEF is selected in a 1.CHA mode
Ratings
Model D M P � -S DMP � -SE D M P � -T DMP �-TE
Type Wiring method Screw Tunnel
Panel mount Unit Extension Unit Extension
Operating characteristics Inverse/definite type
Alerting function Variable between 60 and 110%
Current range(A) DMP06-� 0.5�6
DMP60-� 5~60
Setting time Definite Delay(D-T) 0�60seconds
Operating(O-T) 0�30seconds
Inverse 0�60seconds
Reset type Manual reset
Operating voltage Voltage AC 190~250V
Frequency 60Hz (50Hz)
Aux. contacts OL 2-SPST(95~98) 3A/250Vac resistive load
AL SPST(07-08) 3A/250Vac resistive load
Indicate 7-segment 3-phase current value, fault cause
Bar-LED arrys Load ratio (60~110%)
Mounting 35mm Din-rail/Panel
10 Note) Instantaneous current protection function is option
M e t a - M E C S E R I E S
Operational
power
Note1)
External CT combination
Note1) In is more effective to install the lead-phase capacitor close to a motor in the load side than to install in the line side
11
Note2) Please turn off the reverse phase function when it is used for 1 phase motor
DMP-SZ/SEZ/TZ/TEZ
Digital E M P R
Protect function
Over current Depend on setting time Selectable the inverse/definite
Phase loss Within 3seconds Over 70% of the rate of unbalance
Phase unbalance Within 5seconds Over 50% of the rate of unbalance
Phase reverse Within 0.1seconds Function enable
Stall Within 5seconds Over 180% of the setting current
Lock Within 0.5seconds Setting 200~900% of rated current
Under current Within 3seconds Setting 30~70% of rated current
G r o u n d f a u l t (Note1)
Selectable Grounded current setting by dip s/w
0.05~1.0seconds (100~2500mA)
☞ Lock protection is operated after setting D-time in case of definite time type
Function selection
FUNC Sel Description
1. CHA Inv/dEF Operating characteristics setting(Inverse/definite time type)
2. dEF 0�30(S) Setting the operating time(In definite type)
3. r.P oFF/on Phase reverse enable
4. Und oFF/30�70(%) Under current enable and setting
5. g-F oFF/0.05�1.0(S) Ground fault enable and setting
6. S t l oFF/on Stall enable
7. Loc oFF/200�900(%) Lock enable and setting
8. Ct 1�120 CT ratio setting
9. P.F on/oFF Phase fault enable
Sto Sto Store
☞ 2.dEF is only displayed when dEF is selected in a 1.CHA mode ※ 2.dEF : Refer to page 10
☞ Ground fault sensitive current selection : Refer to page 15
Ratings
Model DMP� -SZ DMP� -SEZ DMP �- T Z DMP� -TEZ
Type Wiring method Screw Tunnel
Panel mount Unit Extension Unit Extension
Operating characteristics Inverse/definite type
Alerting function Variable between 60 and 110%
Current range(A) DMP06-� 0.5�6
DMP60-� 5~60
Setting time Definite Delay(D-T) 0�60seconds
Operating(O-T) 0�30seconds
Inverse 0�60seconds
Reset type Manual reset
Operating voltage voltage AC 190~250V
Frequency 60Hz (50Hz)
ZCT input (07-08) 200mA/110mV
Aux. contacts OL 2-SPST(95~98) 3A/250Vac resistive load
AL SPST(07-08) 3A/250Vac resistive load
Indicate 7-segment 3-phase current value, fault cause
Bar-LED arrays Load ratio (60~110%)
Mounting 35mm Din-rail/Panel
12
M e t a - M E C S E R I E S
Wiring method
External CT combination
13
Characteristics curve
Digital E M P R
14
Ordering M e t a - M E C S E R I E S
Digital E M P R
15