RAMOS A4-Merged
RAMOS A4-Merged
wm
CEILING LIGHT WASHING MACHINE OUTLET CIRCUIT HOMERUN
1 1 1
PP1 PP2 PP3
M
1
PP7 PP7
M
S S S
b b b b b b b b b
S a S a S a
FIRE WALL
PROPERTY LINE
S S S
S S S
S HALLWAY
FIRST FLOOR
E LIGHTING LAYOUT
2 1 SCALE 1:100M
1 1 1
PP4 PP5 PP6
M
1
PP7 PP7
M
S S S
b b b b b b b b b
S a S a S a
FIRE WALL
PROPERTY LINE
S S S
S S S
S TERRACE
SECOND FLOOR
E LIGHTING LAYOUT
3 1 SCALE 1:100M
M
PP7
M
4 4 4
5 PP1 5 PP2 5 PP3
PP1 PP2 PP3
3 3 3
PP1 PP2 PP3
FIRE WALL
PROPERTY LINE
WP
2 2 2
PP1 PP2 PP3
WP WP WP
HALLWAY
FIRST FLOOR
E POWER LAYOUT
4 1 SCALE 1:100M
M
PP7
M
4 4 4
5 PP4 5 PP5 5 PP6
PP4 PP5 PP6
3 3 3
PP4 PP5 PP6
FIRE WALL
PROPERTY LINE
2 2 2
PP4 PP5 PP6
WP WP WP
TERRACE
SECOND FLOOR
E POWER LAYOUT
5 1 SCALE 1:100M
5. ELECTRIC RANGE
(4000 VA) (80%) = 3200 VA
Iw = 3,200 VA / 230 V = 13.91 A
Icb = 13.91 A x 1.25 = 17.39 A
USE 2-3.5mm2 & 1-2.0mm2 TW Cu
IN 20 mm DIA. PVC CONDUIT
USE 25 AT, 2P, CB
DOOR A, B, C, D, E, & F
E DESIGN COMPUTATION
6 1 SCALE NOT TO SCALE
OUTDOOR
E DESIGN COMPUTATION
7 1 SCALE NOT TO SCALE
3. SPARE LOAD
Iw = 3,000 VA / 230 V = 13.04 A
USE 30 AT, 2P, CB
MAIN SERVICE
E DESIGN COMPUTATION
8 1 SCALE NOT TO SCALE
APPLICATION OF DEMAND FACTOR SEC = TOTAL NET LOAD + (0.25 x HRML) ICB = TOTAL NET LOAD + (1.5 x HRML)
230 V 230 V
FIRST 10,000 VA @ 100% D.F 10,000 VA
SEC = 10,716 VA + (0.25 x 1,587 VA) ICB = 10,716 VA + (1.5 x 1,587 VA)
REMAINDER (1,791 VA) @ 40% D.F + 716 VA 230 V 230 V
________________________________________________________ SEC = 48.31 A I CB = 56.94 A
TOTAL NET LOAD = 10,716 VA
USE 2_8.0mm2, THW-2 Cu Wire USE 60 AT, 2P, MCCB
USE 1_8.0mm2, THW-2 Cu Wire
in 25 mm diameter RSC
DOOR A, B, C, D, E, & F
E SCHEDULE OF LOADS
9 1 SCALE NOT TO SCALE
APPLICATION OF DEMAND FACTOR Icb = TOTAL NET LOAD USE 2_8.0mm2, THW-2 Cu Wire
230 V USE 1_8.0mm2, THW-2 Cu Wire
FIRST 3,000 VA @ 100% D.F 3,000 VA in 20 mm diameter RSC
ICB = 10,716 VA USE 40 AT, 2P, MCCB
REMAINDER (1,100 VA) @ 35% D.F + 385 VA 230 V
________________________________________________________ I CB = 14.72 A
TOTAL NET LOAD = 3,385 VA
OUTDOOR
E SCHEDULE OF LOADS
10 1 SCALE NOT TO SCALE
MAIN SERVICE
E SCHEDULE OF LOADS
11 1 SCALE NOT TO SCALE
SUB-FEEDER LINE
USE 2 - 8.0mm2 THW-2 Cu TO MAIN FEEDER
in 25 mm dia. RSC
60 AT , 2P,
INVERSE TIME
40 AT , 2P,
INVERSE TIME
15 AT , 2P 20 AT , 2P
LIGHTING OUTLET 1 2
20 AT , 2P 20 AT , 2P 15 AT , 2P 20 AT , 2P
3 4 LIGHTING OUTLET 1 2
UNIT (SPLIT TYPE) 25 AT , 2P 20 AT , 2P 20 AT , 2P
5 6 3
150 AT , 2P,
MCCB
MAIN CIRCUIT BREAKER
M M M M M M M
SPARE LOAD
PP1 PP2 PP3 PP4 PP5 PP6 PP7
1 - 8.0mm2 1 - 8.0mm2 1 - 8.0mm2 1 - 8.0mm2 1 - 8.0mm2 1 - 8.0mm2 1 - 8.0mm2
THW-2 Cu THW-2 Cu THW-2 Cu THW-2 Cu THW-2 Cu THW-2 Cu THW-2 Cu
in 25 mm in 25 mm in 25 mm in 25 mm in 25 mm in 25 mm in 25 mm
dia. RSC dia. RSC dia. RSC dia. RSC dia. RSC dia. RSC dia. RSC
(GROUND) (GROUND) (GROUND) (GROUND) (GROUND) (GROUND) (GROUND)
MAIN SERVICE
E SINGLE LINE DIAGRAM
13 1 SCALE NOT TO SCALE