BasICColor Display6 Manual en
BasICColor Display6 Manual en
Bats use „instrumentation“ for navigating complex 3-dimensional environments in the dark –
echolocation or Sonar.
The new basICColor display 6 took this perfect blueprint of nature as a model to navigate in 3-D
color space using appropriate instrumentation.
Bats possess a complex neural compass that tracks their movements as they expertly move
through their environment.
The corresponding „compass“ in basICColor display 6 is the new calibration and profiling engine
that has been developed from scratch.
The elegant flight of bats is perfectly matched in the easy to use graphical user interface which
nevertheless offers powerful and sophisticated features for controlling your monitors and viewing
environment.
This means that basICColor display 6 comes with a large number of predefined WORKFLOWs that
represent various common use cases.
Alternatively, you can create your own WORKFLOWs using the EDITOR and save them under a
name of your choice.
This allows you to start any task and any combination of tasks, whether monitor calibration,
profiling, validation, emulating a smaller color space on wide-gamut monitors, color space testing,
light testing for ambient or standardized viewing light, and even the calibration of suitable standard
light stations with a single mouse click.
1. WORKFLOW
This is the main window where you start your calibration, profiling etc. by selecting a predefined
WORKFLOW and clicking the START button. basICColor display 6 remembers the Workflows you
had executed previously.
This is true as long as you switch between 2 different Memory Location/Calibration positions in
NEC monitors. If you load a different WORKFLOW into the active Memory Location (green bullet on
the bottom left) the calibration LUTs will be transferred to the monitor again – and that will take
time. You can identify this situation by the red dot that appears under the <Activate> button.
The steps contained in a WORKFLOW are described on the right side of the window, you can open
the description of the various steps by clicking on the triangles. When the measurements begins,
these will open according to the progress of your WORKFLOW. The graphics window will show the
3D monitor gamut after profiling is done (see image above).
The monitor QC icon (see para 3.2) will indicate the validation result, the light QC icon (see para
3.3) will indicate the result of a check of your lighting situation, if that has been performed in your
WORKFLOW.
Here you can modify, duplicate, delete existing WORKFLOWs or completely recreate a new
one.
For editing, just hover over one of the images and click the pencil (edit) icon.
To create a new WORKFLOW, click <+ NEW> or duplicate an existing workflow by clicking
on the two overlapping squares.
In both cases, the window switches to the EDIT mode, which allows you to change all
settings.
By clicking on the tabs you can switch the steps in the WORKFLOW to on or off.
Green checkmark means that this step will be performed when executing the WORKFLOW
Red cross means that this step will be skipped – even if it holds open locks (see para 2.5),
the settings of this WORKFLOW step will not be displayed upon execution of the
WORKFLOW.
basICColor display 6 is installed with predefined WORKFLOWs, the numbers in front of the
names are only used for sorting in the WORKFLOW and EDITOR windows.
White point D50 - corresponds to the standard for softproofing in the graphics industry
Luminance 160 cd/m2 – for proofing with reflective originals under standard light 500 lx
Tone value curve L* – human perception of tone value gradations.
White point 5500 K – corresponds to the white point of photo light (flash) Luminance 120
cd/m2 - for dimmed environment in studio Tone curve L* – human perception of tone
value gradations.
Native display white point – for maximum brightness and contrast Luminance maximum
– for viewing on a monitor in bright daylight Tone curve L* – human perception of tonal
value gradations.
White point D65 - video/cinema standard luminance 100 cd/m2 - dimmed video editing
suite Tone curve HDTV - the most common of many video tone curves Emulate Rec709 -
matching the tone curve HDTV.
White point D65 - Web "standard" luminance 140 cd/m2 - average office lighting Tone
curve sRGB - still a kind of Web "standard" emulate sRGB - for WORKFLOWs without color
management based on sRGB.
White point D50 - corresponds to the standard for softproofing in the graphic arts industry
Luminance 160 cd/m2 - for proofing with reflective originals under standard light 500 lx
Tone value curve L* - human perception of tone value gradations
NOTE: This WORKFLOW is intended for monitors that are neither hardware-calibratable
nor understand DDC/CI commands, so their brightness cannot be set by software. Before
the calibration starts, you will be asked to measure the white brightness and set it
manually (OSD or Control Panel). On some monitors, the OSD also allows you to adjust the
color temperature. If this is not possible, leave some "air up" in the brightness so that the
adjustment of the LUTs in the graphics card, which usually reduces the blue channel, does
not make the monitor darker than the selected luminance.
Execute this WORKFLOW twice for optimal settings of the white luminance.
2.3.7. „ 7 Light“
• Automatic check of the viewing light based on the monitor calibration, i.e. the
viewing conditions on the monitor and in the viewing light are compared and
checked for agreement
2.3.8. „ 8 Custom“
• The relevant tabs are active and the locks are open
• If required, additional tabs can be activated and locks can be opened or closed
• Compare Sensors
• Correlate Sensors
• DICOM
In basICColor display 6 you can define your individual WORKFLOW and add it to the
predefined ones. Each WORKFLOW consists of up to 6 components:
2.4.1. Calibrate
• Tonal Response – a whole range of tone value curves are available here for graphic
applications and video, (DICOM for Pro version only).
• NEC Memory Location – the name changes depending on the monitor model. NEC
monitors of the PA or SV(R) series have 5 or 10 internal memory locations for LUTs.
These are used to enable fast switching, e.g. between softproof and video, without
having to accept longer download times for the LUTs.
The Memory Locations must be assigned unique names.
• Black Luminance – Luminance of the blackest black. Input either Neutral (only
recommended if a color cast is VISIBLE in the native black), native or default value
to adjust several monitors to each other, the value of the "weakest" monitor
(brightest black) should be entered here.
• Monitor Uniformity - For NEC monitors only, control the uniformity factor.
• Some EIZO CG models have a built-in color sensor that basICColor display 6
supports. In this case an additional instrument is required for light measurement.
2.4.2. Emulate
• Emulation Color Space – Choose from the profile types „Color Space Profile“,
„Monitor Profile“, „Video Profile“. The relative colorimetric rendering intent is
applied automatically. If you choose „None“ no emulation will be applied.
• „RGB Printer Profile“ and „CMYK Printer Profile“ are available in basICColor display
6 Pro only, these options default to the absolute colorimetric rendering intent.
• If the tab „Emulate“ is switched off, the native monitor gamut will be retained.
• NOTE: Emulate is made for environments without color management which are
based on defined color spaces (video, web…). Make sure your Emulation Color
Space matches the color space of your data.
• ICC Version – specify preferences for the encoding of your ICC profile (v2/v4).
• Profile Name – Specify the automatic naming of your profile from several
components.
• NOTE: Do not use too many components since the profile name will become too
long.
• NOTE: If you leave the „Lock“ unlocked you can overwrite or add to the
automatically generated profile name during execution of the WORKFLOW, if so
desired.
• Profile Type – select the profile type from LUT-based or Matrix-based. Since Apple
broke the support for LUT-based profiles for Apple´s own software in Mac OS X
10.12 and higher, we do not recommend to select this type of profile with these
operating systems.
• Save To – select the storage place for your profile (Check for write permissions for
„Custom…“).
• NOTE: On Windows the system profile will not be set automatically if you save
profiles to a „Custom…“ folder.
• Chromatic Adaptation – select chromatic adaptation model if you deviate from D50
and want to adapt to the D50 white point, default is CAT02.
2.4.4.Validate
• Targets – selects a text file with RGB reference values that specify how many color
patches you want to test your profile with, you can import your own CGATS text file.
• Tolerances – XML file that defines the tolerances f for ΔCmax, ΔE ø, ΔEmax gray,
ΔEmax color, ΔEmax promaries, ΔLuminance of the white point, Δab white point as
well as the color distance formula for your validation process (Default = ΔE2000).
• Checks if your monitor is able to display the emulated gamut completely and
correctly. If emulated it checks the emulated gamut.
• Color Space – select from the profile types „ColorSpace Profile“, „Monitor Profile“,
„Video Profile“. Printer Profiles can be selected in basICColor display 6 Pro.
• Ambient Light – check your ambient light according to ISO specifications (should be
below 32 lx, shall be below 64 lx).
• Viewing Light – select if you want to check or calibrate your viewing booth or not (in
basICColor display 6 Pro suited lights like Just ColorCommunicator / moduLight or
SmartLightning System can be calibrated automatically).
• White Point – Color temperature, „Auto“ will use your monitor calibration setting
„White Point“ for checking or calibration your viewing light.
• Illuminance – „Auto“ will use your monitor calibration setting „White Luminance“ for
checking or calibrating your viewing light (automatic calibration for suited lights in
basICColor display 6 Pro only, otherwise dim your viewing light manually to the
appropriate illuminance).
• UV – On/Off will switch the UV content of your suited viewing light (basICColor
display 6 Pro only).
If you switch monitor calibrations and your WORKFLOW contains a calibratable light,
the light will be switched automatically to match the new viewing conditions – an
absolute stand-alone feature of basICColor display 6 Pro!
All parameters can be predefined and they can separately be hidden (locked)
basICColor display 6 gives you an immediate signal in its interface, telling you what the
status of your monitor(s), light(s) and instrument(s) are.
The „Active WORKFLOW“ and thus the selected calibration and profile is shown in the
bottom left position of the main window .
Clicking the „Active WORKFLOW“ icon will take you to the 3D view with the option to save
the respective report. A click on the button <DONE> will take you back to the main window.
basICColor display 6 shows the status of the selected monitor, regardless if it is just
calibrated or if you had activated an existing WORKFLOW that contains Validation.
Validation ok
Validation NOT ok
The active WORKFLOW can be re-validated by just clicking on the red/green/blue status
symbol. You only need to recalibrate if your validation result is negative.
The same is true for checking your ambient or viewing light (light booth).
The descriptor „Viewing Light“ will change to the name of the connected light booth if one
is detected and can be calibrated bay basICColor display 6.
With basICColor display 6 Pro you can control the UV content for suited viewing lights by
clicking the lamp symbol.
LacunaSolutions SmartLightning System: Cold & Warm White, Blue, Green, UV 360nm, UV
400nm
basICColor display 6 shows all connected monitors and measuring instruments with their
respective properties. Select the monitor you want to calibrat/profile/validate in the drop-
down menu.
RGB-curves:
This monitor cannot be hardware-calibrated, either because it is not capable at all (e.g.
most Apple monitors) or because the hardware calibration capability could not be
detected by the software. Calibration will be done in Video-LUTs on the graphic card.
DDC in black and white: The white luminance can be set via DDC/CI
commands. This prevents the necessity of setting the luminance via video-LUTs.
DDC in color:
In addition to the white luminance, color temperature can be set via DDC/CI commands. .
Logo:
These monitors can and will be hardware-calibrated.
• Name / Model
• Resolution
• Size in inches
• Hours of usage
• Serial No.
• Embedded Luts
• Brightness (DDC-CI)
• 3D Lookup Table
By hovering over the instrument symbol you can see its capabilities and settings for
example:
• Name / Model
• Inactive – if you have several connected instruments but the one over which you
hover your mouse is not selected
https://www.displayspecifications.com
In today’s world there are 3 major industries that creative professionals create content for
• Internet
• Film & Video
• Print
• Medical
Each of these categories work with their own set of standards which continue to evolve
rapidly. .
The internet has embraced sRGB and D65 as its standard, not so color management. In
some browsers it has to be switched on with cryptic commands.
print has different ISO standards for different printing methodologies like sheetfed, web or
offset printing presses, using various paper types like coated or uncoated. ICC-based
color management is fully established in the printing industry.
The film & video category is the one changing the most. There is a rapid transition in
advertising going on, more people today see advertisements on social media platforms
like Facebook or YouTube than on print. This goes hand in hand with the advancement in
monitors and televisions as well as cameras to capture higher resolution content with
increasing dynamic range. ICC-based color management is a myth for most products (and
users) in these industries.
The main goals of basICColor display 6 are to emulate these different color spaces on
inexpensive desktop monitors (wide gamut to facilitate the seamless switching between
different setups.
Wide gamut monitors from Eizo and NEC have the capability to emulate a smaller color
space, either by setting a color matrix or by setting specific primaries. 3D LUTs for the
same purpose are also supported. This is especially important for creating content for
video and the internet, the sRGB and the REC709 color spaces are identical in size, only
the tonal transition is different. Applications like Adobe Premiere Pro render all of their
content to REC709, making it very important to set the monitor to emulate that space.
basICColor lets you pick any color space for the emulation, as long as you have an ICC
profile for it. We install a set of subfolders in your profile folder, one containing the most
common video standards like P3DCI or REC709, another the most common RGB working
spaces like ProPhoto or AdobeRGB1998.
When you add an emulation into your WORKFLOW the emulation becomes part of the
calibration. The entire monitor including its ICC profile then represents the emulated color
space. Several graphics demonstrate the color mapping and a detailed validation report
confirms the monitor’s usability in that stat
While executing a WORKFLOW containing Emulation several graphics show the progress
and the result of the Evaluation of the emulated gamut. A detailed report proves the ability
of your monitor to display the print gamut.
IMPORTANT! The WORKFLOW component „EMULATE“ should not be activated with Color
Space set to „Auto“ if you did not emulate a smaller gamut. Setting The Color Space to any
different gamut than the native monitor gamut will in such a case show the theoretical
ability of the monitor to emulate this gamut.
If Emulate is active, Color Spce set to „Auto“ will automatically evaluate the emulated
color space..
While print professionals use various programs to see accurate predictions of their CMYK
content (soft proofs) it would often be great to get a quick preview of what an RGB image
would look like printed in whatever retouching program you may find yourself. With
basICColor display 6 you can choose to emulate a CMYK printing space and use a 3D LUT
to simulate a CMYK conversion from your favorite working space, giving you the option of
relative colorimetric intent with black point compensation or perceptual intent just like in
the most sophisticated applications like Adobe Photoshop.
basICColor display 6 Pro allows not only for emulating RGB-spaces but also for emulating
printing spaces. The rendering intent absolute colorimetric is applied in these cases, thus
simulating paper white as well.
You can store a native calibration in one memory location and the emulated calibration in
another one and switch rapidly between the two for a quick preview of you print.
Since the luminance of cheap monitors and not so cheap Apple MacBooks and iMacs can
no longer be set via external software – thank you, Apple! – the WORKFLOW „6 Manual
pre-cal“ has been added.
When you start the WORKFLOW, a window with 2 options for setting the desired White
Point and White Luminance appears. You can edit these 2 parameters or accept the
default values by clicking „NEXT –>“.
Here you will be prompted to calibrate the instrument (if applicable) and the measure
window will be opened which will show the 2 options „CANCEL“ and „MEASURE“ and a
graphical representation of your instrument (a MYIRO-1 in this example).
Now begin to adjust the luminance using either the hardware controls in the OSD of your
monitor or by using the monitor control panel. You should set luminance slightly above the
aim value in order to give the software some leeway for correcting the white balance. The
further off the white balance in the beginning, the more luminance overhead is required.
Once you have set the luminance to a satisfactory value click „ACCEPT“ in the main
window in order to start the calibration.
Most professional NEC monitors possess 5 Memory Locations, some even have 10 (need
to be activated in the OSD). You can assign each of those to a WORKFLOW and switch
with the click of one button from Softproof for printing to REC709 for video, all within a
few seconds. On Eizo monitors the interface to the monitor is so fast that upon switching
all hardware parameters are downloaded into the monitor, giving you an unlimited number
of virtual Memory Locations .
You switch calibrations by clicking on the respective bullet – for NEC the Memory
Locations are numbered. The numbers in the WORKFLOW names must not be confused
with the Memory Locations, these are for alphanumerical sorting of the WORKFLOWS in
the selection bar. :
In this case, loading the new WORKFLOW takes its time. Thus it makes sense to store
those WORKFLOWs you will need regularly in different Memory Locations.
The active WORKFLOW – and thus the system profile – is indicated by a separate bullet
and the name of the WORKFLOW to the left of the WORKFLOW selectors.
This window can be brought up by clicking the „Active WORKFLOW“ button and you can
save the report at any time.
If the WORKFLOW contains calibration, emulation, evaluation, light… these steps will be
shown in the report as well.
6.1. Option
The optional Pro Version offers additional features, which are described here. The Pro
Version is activated with a TAN, either retroactively for an already installed and licensed
basICColor display 6 or directly when purchasing the Pro Version (see Licensing Manual).
6.2. Uniformity
Here you can set if and with how many measuring fields you want to check the
homogeneity of the monitor. The ISO 14861 standard defines the number, position and
tolerances of the measuring fields for the graphics industry, the DICOM standard (see 6.3.
DICOM) defines these parameters for medical applications. For both cases, the values are
stored in basICColor display 6 Pro.
For graphic applications, 25 measuring fields (a 5x5 pattern) are standard-compliant, for
DICOM, a total of 5 measuring fields (this is selected with the On selection). For wide
format monitors we have added a 5x3 pattern. This is not standard-compliant, but
practice-oriented. So, if it is not about a certification of the monitor like Fogra or UGRA, the
smaller number of measuring fields can be chosen to evaluate the homogeneity of the
monitor, because the deviations mainly occur between the center and the edges of the
monitor.
For calibrating and checking monitors for medical reporting basICColor display 6 Pro has
its own WORKFLOW and the necessary procedures and settings, e.g. the DICOM tone
curve to obtain JNDs (Just Noticeable Differences) on the gray axis.
In addition to the emulation of RGB color spaces basICColor display 6 Pro has the ability
to emulate and/or check (evaluate) print color spaces in the CMYK color model.
Attention! This calibration method is to be used ONLY for the following case:
You want to view a CMYK softproof (print preview) without converting the data into this
color space or leaving the RGB-based design program. This function is only available in
basICColor display 6 Pro!
So-called wide gamut monitors (gamut = color gamut) from e.g. NEC or EIZO offer the
possibility to emulate a smaller color space by a color matrix, a 3D LUT or by setting the
primary colors. This can be used to limit the monitor to one printing color space, i.e. to
view RGB data as if it had been converted to the CMYK printing color space.
basICColor display 6 allows to emulate any CMYK color space as long as an ICC profile is
available. Therefore we install a number of folders in the system's profile folder, which
already contain the most common printing profiles like ISOcoated v PSOcoated,
PSOuncoated, ISOnewspaper ... Installed print profiles already on your system can of
course also be used.
If you activate the tab "Emulate" in a WORKFLOW, or use a ready-made one that contains
the emulation, the emulation of the selected color space is executed as part of the
calibration. The entire monitor then represents the emulated color space and the profile
created describes the monitor calibrated in this way.
IMPORTANT: The WORKFLOW step "Evaluate" is specifically for this purpose and should
not be used with other WORKFLOWs, unless you want to determine whether your monitor
is capable of displaying a certain color space. In this case, the tab "Emulate" remains
disabled and the tab "Evaluate" is used to check whether a desired color space could be
emulated in a meaningful way.
The WORKFLOW step "Validate" does not make sense in case of emulation and should be
switched off.
basICColor display 6 Pro allows to measure light with a spectrophotometer and shows the
spectral curve.
The spectral values can be saved as a CGATS file by clicking on the Spectrum icon and
used e.g. in basICColor input 6 (Pro) as a light source for profiling.
The report for the light measurement additionally shows the Color Rendering Index (CRI),
both in the general form and the extended CRI. The general CRI uses 8 spectral reference
colors and evaluates the color rendering under the measured light against standard light
D50.
The white point editor can be called up directly after a WORKFLOW has been executed by
clicking on the last point of the progress bar. This point is not jumped to automatically like
the other points, since editing the white point is not a task that is performed in every
WORKFLOW.
The editor can be opened later by activating the desired WORKFLOW with the profile to be
edited and clicking on the "Active WORKFLOW" button. Then click again on the last - not
active - point in the progress bar.
The interactive white point changes are achieved through the VideoLuts of the active
monitor. They are, however, approximations. Once you achieved the color you want you
need to click on “Save Correction”. This stores the x and y correction for the active monitor
and the active instrument ONLY. You can verify the correction in the tooltip of the active
instrument.
To remove the correction go back to White Point Edit and click “Reset Correction”.
The white point correction will be applied to every measurement from now on, so
recalibrate your monitor for the final result.
In basICColor display 6 Pro, monitor measurement devices can be correlated with another,
(preferably) high-quality measurement device. This ensures that the measurements of
different sensors are (as far as possible) comparable to the measurements of a reference
measuring device and to each other. A perfect match cannot be guaranteed due to the
different designs.
To start a WORKFLOW with sensor correction, the reference instrument must first be
selected as the active measuring instrument, in our example the MYIRO-1.
After starting the reference measurement with "MEASURE", the reference device measures
a series of colors on the monitor, then basICColor display 6 Pro prompts you to connect
another measurement device and (or if already connected) select and click into this field
to collect data from another measurement device.
Now you can decide to correlate all sensors you have used so far, or you can select
another one or even disconnect the first, already corrected measuring device and connect
and select the next instrument. This procedure can be repeated as often as you like.
If you click on "Correlate measured sensors", the process is completed and the "Report"
icon appears in the upper right corner with which you can save a detailed report.
Uncorrected:
Corrected:
The deviations of the measuring devices have been reduced on average from a maximum
of 6.5 ΔEoo to 0.5 ΔEoo, the maximum deviations from 13.6 ΔEoo to 1 ΔEoo (with only
one outlier upwards).
In addition to the numerical evaluation, the values of all measuring devices on all color
patches are displayed graphically, here an extract from the report:
Corrected:
All corrections are stored as .ccmx files in a new "Instruments" folder for each monitor on
which a correlation has been made, in a monitor-specific folder. This specific correction is
applied the next time the corrected instrument is measured on the respective monitor.
Why so complicated?
Colorimeters have sensor metamerism due to their design. The manufacturer tries to
reduce this by using prefabricated correction matrices. With the i1 Display Pro, for
example, you can choose between 8 corrections for different monitor technologies, with
the Spyder 5 between 4 global corrections for different backlights, with basICColor
DISCUS between 30 (more are reloadable) corrections for monitor models.
basICColor display 6 Pro allows you to optimize each measurement device for each
individual monitor to achieve optimal results that are as close as possible to a reference
device.
Under "basICColor display" in the menu bar (Mac) or under "File" (PC) you will find
"Preferences...".
Starts the Helper application after quitting basICColor display. On Mac you will find it in
the menu bar in the upper right corner, on PC in the system tray. While basICColor display
is active, the Helper App is inactive (gray icon).
Here you can set the time after which you want to be reminded of a new calibration.
This option should only be activated if your monitor is not hardware-calibratable and you
don't know if it supports the DDC/CI commands (If you only use Apple monitors, this
option can be switched off, since neither of these applies). The program will take a little
longer to start if this option is activated.
Pro Features
7.6. Measurement
When using a spectrometer you can either obtain colorimetric values from the instrument
or you can have basICColor display 6 Pro calculate the colorimetric values for 2 different
observers,
If you correlated 1 or more instruments you can switch the correction matrices on or off
by checking/unchecking this box.
7.8. Readouts
You can switch the measurement readouts from XYZ to xyY or uvY with their radio
buttons.
Activate the option "Automatically check for updates". When the program is started,
basICColor server checks whether a new program version is available and suggests it for
download.
NOTE: Since this does not work reliably with every system, it is recommended to check
regularly at www.basiccolor.de to see if a new version is available. The licenses are valid
for all major versions, e.g. 6.1.0 to 6.2.0.
The proxy server configuration is only needed if there is an active proxy server in your
network that prevents a connection to the basICColor server - ask your system
administrator.
Here you will find information about the program version and a download link to the
TeamViewer software that we can use to access your computer in case of support.
8.3. License...
Please refer to the document "EN - basICColor Licensing.pdf", which is installed with the
software in the folder "PDF Manuals".
Together with basICColor display 6 we install a control panel, a helper app, which
becomes active when basICColor display is closed and if the „Autostart Helper App“
checkmark in Preferences is checked .
It warns when a recalibration is necessary. The interval for the reminder is set in
basICColor display 6 under "Preferences...". see para 7.2.
You can also switch WORKFLOWs (calibration and profile) directly in the helper app
without opening basICColor display 6.
The WORKFLOW Status window shows an overview of connected monitors and their
status. You can also switch the WORKFLOWs (profiles) here ("activate") or start
basICColor display 6 ("start display").
10.1. Colorimeters
basICColor DISCUS
basICColor SQUID 3 (X-Rite i1Display Pro), Datacolor Spyder 3 (Windows only), Datacolor
Spyder 4 (Windows only), Datacolor Spyder 5
Datacolor SpyderX
EIZO Swing
EIZO Calibration Sensor
NEC SpectraSensor Pro (X-Rite i1Display Pro) X-Rite i1Display Pro
X-Rite i1Display Pro Plus
10.2. Spectrometers
Eizo:
NEC:
We also support generic DDC protocol, it is impossible to say which monitors react to that.
Tested: Cinema HD (brightness only), Dell UP2516D (brightness and RGB gains), HP
Dreamcolor (brightness and RGB gains), some LG monitors. BenQ SV271 pretends to
support the protocol, but the screen doesn’t change .
basICColor diLIGHT
basICColor LEDlight
JUST Color Communicator 2
JUST moduLight (with D50 & D65 LED, and with UV LED)
LacunaSolutions SmartLightningSystem
Software - Copyright © 2019, 2020 Karl Koch & Franz Herbert (basICColor). All rights
reserved..
Guide - Copyright © 2019, 2020 Karl Koch & Franz Herbert (basICColor). All rights
reserved.
The contents of this guide are for informational use only. It is subject to change without
any notice. basICColor takes no responsibility or liability for inaccuracies or errors that
may appear in this document. No part of this manual may be reproduced, transmitted,
transcribed or translated into any language without the written permission of
Ingenieurbüro Dipl.-Ing. Karl Koch.
The copyright for published objects created by the authors themselves remains solely with
the author of the pages. Any duplication or use of objects such as diagrams, sounds or
texts in other electronic or printed publications is not permitted without the author's
agreement.
The basICColor lettering with the fingerprint is a word/image trademark of basICColor. All
brands and trademarks protected by third parties are subject without restriction to the
provisions of the applicable trademark law and the ownership rights of the respective
registered owners. The mere mention of a trademark does not imply that it is not
protected by the rights of third parties.
11.3. Credits