VSOL Hardware Information

What is a Single Banker Device? 1


What is a Low RAM/Memory device? 1
How to Check Memory of any VSOL device? 1
How to Check Banker Details of any VSOL device? 2
Low Memory Models 2
Netlink 2
Syrotech 2
Single Banker Models 3
Netlink 3
Syrotech 3

What is a Single Banker Device?


During firmware upgrade, every device has reserve space to install the
new firmware. After successful firmware update the device will switch to
the reserve space and start functioning normally. Incase of any issues,
the device will fallback to the original banker. But Single Banker devices
will not have this reserve space, so any issue during firmware update will
make this device unusable. And usually the ISP has to replace the
device for the customer.

What is a Low RAM/Memory device?


These kinds of devices usually have lesser memory than other devices
in the same device category (Dual band)

How to Check Memory of any VSOL device?


1. Telnet to the device mgmt ip address
2. Type the command - enterlinuxshell
3. Type the Shell Password - You can get this after exporting the config
file
4. After in the shell mode, Type the command - cat /proc/meminfo
How to Check Banker Details of any VSOL
device?
1. Telnet to the device mgmt ip address
2. Type the command - enterlinuxshell
3. Type the Shell Password - You can get this after exporting the config
file
4. After in the shell mode, Type the command - cat /proc/mtd
5. If you see only k0,r0 the device is single banker (risk for firmware
updates)
6. If you see both k0,r0 and k1,r1 then the device is dual banker (safe for
firmware updates)

Low Memory Models

Netlink
Dual Band - Hardware Version V4.1 and software version starts with V3
(Example - V3.2.02-221129)
Dual Band - Hardware Version V4.2 and software version starts with V3
(Example - V3.2.02-221129)

Syrotech
Dual Band - Hardware Version V4.2G and software version starts with
V3 (Example - V3.2.02-230110)
Dual Band - Hardware Version V4.3D and software version starts with
V3 (Example - V3.2.02-230110)
Dual Band - Hardware Version V4.2C and software version starts with
V3 (Example - V3.2.02-230110)
Single Banker Models

Netlink
Single Band - Hardware Version V3.7 and firmware version starts with 3
(Example - 3.1.02-221201)
Single Band - Hardware Version V4.2 and software version starts with
V1 (Example - V1.0.00-230904)

Syrotech
Single Band - Hardware Version V3.7L and firmware version starts with
3 (Example - 3.1.02-240517)
Single Band - Hardware Version V5.0 and firmware version starts with 3
(Example - 3.1.02-240517)

Note: The analysis is done from the modes we have encountered so far
in the field. There could be deviations in newer models. Use the
commands provided and check the memory and banker details before
any CPE purchase and make an informed decision.