Line Sizing Criteria
Line Sizing Criteria
Page
XXXX JSD 0000 02 X 27/46
Notes:
Maximum
ρv² (max) Pressure Drop
Velocity
Pa bar/km
m/s
1. VACUUM SERVICE 4 % Abs. Press. Max. 90
2. COMPR. SUCT. 0.2 – 0.7 (2)
(2)
3. COMPR. DISCH. GAS 0.4 – 1.0 (2)
4. STEAM (sub-headers)
a) 1 barg 0.4 – 1.0
15 000 (3)
b) 10 – 40 barg 1.0 – 2.0
c) > 40 barg (5)
5. STEAM (long lines)
a) 1 barg 15 000 0.1 – 0.2 (3)
b, c) > 10 barg 0.2 – 1.0
6. KETTLE REBOILER OR NATURAL
0.2 – 0.4 (4)
CIRCULATION RETURN LINE
7. OVHD VAPOUR FROM STRIPPER 0.2 – 0.45 (4)
8. COLUMN OVHD (P ≥ atm) 15 000 0.3 – 0.6 (1)
9. COLUMN OVHD (vacuum) TOTAL = 5 mm Hg max 90
10. GAS LINES
P ≤ 20 barg 6 000
20 < P ≤ 50 barg 7 500 (4)
50 < P ≤ 80 barg 10 000
P > 80 barg 15 000
Notes:
STEAM CONDITIONS
PIPE SIZE
SATURATED SUPERHEATED
< 2” 10 m/s 15 m/s
3” – 8“ 30 m/s 40 m/s
> 10” 40 m/s 60 m/s
(4) For large diameter lines of over 300 mm, it should be verified that the following
velocities are not exceeded:
where:
ρm = density of mixed phase
vm = velocity of mixed phase (equal to 10 to 23 m/s)
“C” VALUES
CONTINUOUS SERVICE
150 For high alloy/corrosion resistant material.
For uniform corrosion with rates lower than 0.3 mm/a, or when a
100
corrosion inhibitor is used.
80 For uniform corrosion with rates higher than 0.3 mm/a.
DISCONTINUOUS SERVICE
200 For all cases.
Project N° Unit Document Code Serial N° Rev. Page
XXXX JSD 0000 02 X 30/46
Velocity shall be in any case lower than 50 m/s in continuous services except vacuum
services, while for discontinuous services (as safety valve discharges to flare) velocity
shall be lower than:
Notes:
ANNEX N. 2
ALLOWABLE ∆P FOR COLUMN OVHD
100
10
P bar abs.
0.1
0.1 1 ∆P admissible bar/km 10
Project N° Unit Document Code Serial N° Rev. Page
XXXX JSD 0000 02 X 46/46
ANNEX N. 5
RECOMMENDED VELOCITY FOR INLET/OUTLET LINES OF COMPRESSORS
1
RECOMMENDED GAS VELOCITY
FOR LINES ATTACHED TO COMPRESSORS
100
Gas Velocity (m/s)
10 1
Reciprocating and Centrifugal compressors: acceptable velocity in area delimited by lines 2 and 3.