Ivium Technologies Brochure
Ivium Technologies Brochure
station
with
integrated
impedance
analyser
CompactStat ● Corrosion
& ●
●
Battery testing
Electroanalysis
● Expandable with modules
● PC control via USB interface
● Nano-electrochemistry ● Data analysis software included
IviumStat
Methods and techniques :
Sweep techniques
Shown data was recorded by TNO Industrie & Techniek, Den Helder.
Electroanalysis
● Amperometric detection
● Potentiometric Stripping
● AC voltammetry
● Differential Pulse
● Square Wave
● AC detection
Impedance measurements
Batch processing
Special functions
● Automatic current ranging: the instrument will automatically select the optimal current range setting
● Pretreatment: up to 5 levels may be defined to condition the electrode before the actual measurement starts.
The E/I values during “Pretreatment” are recorded and stored with the primary data.
● Apply wrt OCP: the measurement potentials are defined relative to “Open Cell Potential”.
Before the measurement starts, the OCP is detetermined in a zero-current configuration.
The OCP monitor transient is recorded and stored with the primary data.
● Ohmic drop compensation: the applied
potential is corrected by current feedback
● Analog inputs : the 8 analog inputs from the
peripheral port may be recorded
simultaneously with the primary results.
The results are visualized graphically, and
stored with the primary data.
● Signal view: the current and potential transients
are shown in an oscilloscope type screen.
During ac-techniques, the quality of the
perturbing and resulting sine-waves is
visualized. Under dc-conditions, the
E/I signals can be inspected for the presence
of specific noise elements.
Options and modules :
HiMUX: High Performance Electrochemical Multiplexer
This multiplexer module can work with 8 independent Electrochemical cells with each 4 electrodes. An IviumStat or CompactStat can control
up to 8 HiMUX modules (64 channels). Because each channel has its own electrometer, its performance is superior to the switchbox approach:
● Fast channel switching: Because no switches are connected to RE&S, there are no (dis-)charge
currents when channels are switched. High impedance (reference-) electrodes
require a long stabilization time after each switch. The HiMUX keeps RE&S always
connected, and allows for fast channel switches without disturbing the electrochemical cells.
● Excellent high frequency performance: The design with 8 independent active
electrometers allows the whole RE/S cable-length to be enclosed within driven shields.
This results in a very low leakage capacitance, and measurements can be done in the
high frequency range without performance loss compared to the un-multiplexed situation.
Each Electrometer: ♦ Input impedance: >1000 Gohm //<8 pF
♦ Bandwidth >16 MHz
● Maximum compliance WE & CE: 5A
● Automatic channel selection is integrated in the software.
MultiWE32: IviumBoost:
This module will accommodate cells with 32 Working Electrodes, that share The IviumBoost will increase the maximum current of
a single CE and RE. The potential is applied to all channels continuously, the IviumStat or IviumStat.XR:
thus applied E is not multiplexed! Each channel: ● 2 models: ♦ maximum 40A at ±10V
● Max current: +/-1mA ♦ maximum 20A at ±20V
● 2 modes: ♦ standard: fixed E wrt RE ● Bandwidth >100kHz
♦ scanning: E scans as the primary ● w x d x h = 47x36x14cm, 16 kg
WE, but with an offset ● 100-240V, 50-60Hz, 1000W
● programmable offset +/-4V, 0.125mV resolution,
independent for each channel
Second working electrode (WE2) with programmable potential offset wrt RE or WE1.
The bipotentiostat is fully integrated in the potentiostatic Sweep and Transient methods. Its data is recorded simultaneously with the primary channel,
and visualized in the same plot using a secundary current axis. Maximum scanrate or minimum interval times are same as for the primary channel.
● 2 configurations ♦ “standard” : WE2 at a fixed potential w.r.t. RE
♦ “scanning” : WE2 at a fixed offset potential w.r.t.the primary WE
● Maximum current ±30 mA ● Compliance voltage ±2 V w.r.t. primary WE
● Applied offset potential range ±2.0 V ● Applied potential resolution 0.0625 mV
● Current ranges 1 pA to 10 mA in 11 (lower 4 ranges use gain amplifier).
● Measured current resolution 0.076 % of current range, and 0.0000023 % using gain amplifier.
● Minimum current resolution 0.15 fA
● Data acquisition simultanously with primary WE1, 100 kHz max.
sampling rate
● Programmable response filter 1 MHz, 100 kHz, 10 kHz, 1 kHz, 10 Hz
The PDA module allows the simultaneous recording of differential bipolar high-ohmic external voltages,
such as voltage monitors, reference or pH meters. The module is stackable up to 8 units (64 channels).
● Each unit can record 8 channels. ● Input impedance: > 10^12 ohm
● Differential measurement range: ± 2V ● Maximum common mode voltage: ±15V
The Peripheral Port Expander facilitates the connection to the peripheral port. This connectionbox has
32 sockets for 4 mm banana plugs, that allow direct connection to the various analog/digital inputs & outputs.
● Connector type 32 X 4 mm bananasocket
Specifications :
IviumStat CompactStat
System Performance
Current compliance ±5 A ±30 mA (±1 mA in USB powered mode)
Maximum output Voltage ±10 V below 1 A and ±8 V up to 5 A ±7.5 V
Potentiostat Bandwidth 1 MHz for small signals, 300 kHz for large signals >1 MHz
Stability settings High Speed, Standard, and High Stability High Speed, Standard, and High Stability
Programmable response filter 1 MHz , 100 kHz , 10 kHz , 1 kHz , 10 Hz 1 MHz , 100 kHz , 10 kHz , 1 kHz , 10 Hz
Signal acquisition dual channel 16 bit ADC, 100.000 samples/sec dual channel 16 bit ADC, 100.000 samples/sec.
Potentiostat
Applied potential range ±10 V, with 0.33 mV resolution ±4.096 V , with 0.125 mV resolution
Applied potential accuracy 0.2 %, or 2 mV 0.2 %, or 2 mV
Current ranges ±10 nA to ±10 A in 10 steps ±10 nA to ±10 mA (to 1 mA in USB powered mode)
High sensitivity current ranges ±1 pA, ±10 pA, ±100 pA, ±1 nA ±1 pA, ±10 pA, ±100 pA, ±1 nA
Measured current resolution. 0.015 % of current range, minimum 0.15 fA 0.015 % of current range, minimum 0.15 fA
Galvanostat
Applied current resolution 0.033 % of applied current range 0.0125 % of applied current range
Applied current accuracy 0.2 % 0.2 %
Potential ranges ±1 mV, ±10 mV, ±100 mV, ±1 V, ±10 V ±0.4 mV, ±4 mV, ±40 mV, ±0.4 V, ±4 V
Measured potential resolution 0.003 % of potential range, minimum 40 nV 0.003 % of potential range, minimum 16 nV
Impedance Analyser
Frequency range 10 µHz to 2 MHz 10 µHz to 2 MHz
Amplitude 0.015 mV to 1.0 V, or 0.03 % to 100 % of current range 0.015 mV to 1.0 V, or 0.03 % to 100 % of current range
DC offset 16 bit dc offset subtraction, and 2 dc-decoupling filters 16 bit dc offset subtraction, and 2 dc-decoupling filters
Dynamic range 12 nV to 10 V, and 0.05 fA to 5 A 4 nV to 4 V, and 0.05 fA to 30 mA
Electrometer
Input impedance >1000 Gohm //<8 pF >1000 Gohm //<8 pF
Input bias current <10 pA <10 pA
Bandwidth >16 MHz >16 MHz
Special functions
Ohmic drop compensation 2 V/current range, 16 bit resolution 2 V/current range, 16 bit resolution
Safety features automatic disconnect on internal/external exceptions automatic disconnect on internal/external exceptions
Peripheral connections
8 Analog in, and 2 analog out 0 to +4 V, 16 bits resolution 0 to +4 V, 16 bits resolution
2 Digital inputs, and 3 Digital outputs 0 to +5 V 0 to +5 V
I-out, and E-out analog monitor for cell current and potential analog monitor for cell current and potential
AC-out ±0.5 V sinewave 10 µH-2 MHz with variable attenuation ±0.5 V sinewave 10 µH-2 MHz with variable attenuation
Channel-X, and Channel-Y inputs ±4 V: to record impedance from peripheral devices ±4 V: to record impedance from peripheral devices
Environment
power requirements 100-240 V, 47-63 Hz, 150 VA in USB powered mode: standard 5 V, 500 mA
external adapter: 100-240 V, 45-65Hz, 6 VA
Interfacing USB 1.1 or 2.0 compliant USB 1.1 or 2.0 compliant
Size w x d x h = 26 x 33 x 12 cm w x d x h = 12 x 26 x 2.5 cm
Weight 4.0 kg 0.6 kg
PC requirements Windows XP or Windows Vista, with free USB port Windows XP or Windows Vista, with free USB port
IviumStat.XR CompactStat-Plus
Specifications as IviumStat except: Specifications as CompactStat except:
System Performance
Current compliance ±5 A ±250 mA
Maximum output Voltage ±20 V ±20 V
Potentiostat
Applied potential range ±10 V with 0.33 mV resolution, or ±4.096 V, with 0.125 mV resolution, or
±20 V with 0.66 mV resolution ±20 V, with 0.66 mV resolution
Current ranges additional 100 mA range
Galvanostat
Potential ranges ±2 mV, ±20 mV, ±200 mV, ±2 V, ±20 V