Dubai Guide For Built Environment Universal Design 1 Compressed
Dubai Guide For Built Environment Universal Design 1 Compressed
2
3
5
People with
disabilities shall
be called "people
of determination"
6
Disability is in fact the inability to make progress and
achievements, the achievements that people of determination
have made in various felds over the past years are proof
that determination and strength can do the impossible
and encourage people to counter challenges and diffcult
circumstances while frmly achieve their goals.
H.H. Sheikh
Mohammad Bin Rashid
Al Maktoum
7
Introduction
8
About
theguide
This illustrated guide has dual purposes, frstly to be used user-friendly format.
as audit hand book integrally with the classifed universal Designers and architects can refer to any of accessible
design checklist in order to ensure the compliance with Dubai design standards, codes, practice guides, and specifcations
Universal Design Code requirements. Secondly, to be used as documents of buildings components, equipment and services,
an inclusive design guide which helps in demonstrating the but should exceed the minimum requirements of Dubai
design characteristics of accessible built environment that Universal Design code illustrated in this Guide.
enables everyone to approach, enter, use, and egress from the Dubai Universal Design Audit Guide does not prevent by any
buildings safely and independently. Taking into consideration means the use of technology and products as alternative
broad types of human abilities and circumstances including accessible solutions if they at least provide equivalent
persons with physical, visual, hearing, and intellectual accessibility of the prescribed requirements.
impairments, elderly, childhood, gender, mobility device users, All dimensions and measurements in all fgures are in metric
and tourist equitably and dignifedly. units, mainly in mm and meters, in a range of fexibility that
Dubai Universal Design Audit Guide promotes better allows the designers to change according to the primary use
practice in early stage of built environments design and its of the building, like those especially designed for serving
commissioning, operation and management at a later stage, children.
as well as retroftting the existing built environments, and In addition to the above, all scope requirements of Dubai
putting all necessary relevant information in a direct and Universal Design code should be followed.
9
10
Index
11
E | ENTRANCE Page NO.
E1 41
E2 42
E3 43-45
E4 44-45
E5 51
E6 46
E7 46
E8 47
E9 44-45
E10 48
E11 49
E12 50
E13 50
E14 50
E15 50
12
ER | Entrance - Counters And Reception Areas
ER1 53
ER2 54
ER3 55
ER4 54
ER5 56
ER6 56
13
PE11 67
PE12 69
PE13 70
PE14 61/70
PE15 71
14
Plg | Playgrounds
Plg1 78
Plg2 78
Plg3 78
Plg4 78
Plg5 78
PF | Floor Surface
PF1 79
PF2 79
PF3 80
PF4 80
PF5 81
PF6 82
PF7 83
PF8 84
PF9 84
PF10 85
PF11 86
PF12 87
PF13 87
PF14 88
15
PF15 89
PF16 90
PI | Internal corridors
PI1 91
PI2 91
PI3 92
PI 4 92
PI 5 91
PI 6 93
LCG | Guardrails
LCG1 95
LCG2 95
LCG3 95
LCG4 96
LCG5 96
LCG6 97
16
LCWT | Warning tactile surface
LCWT1 98-99
LCWT2 98-99
LCWT3 100
LCWT4 100
LCWT5 101
LCWT6 101
LCR | Ramps
LCR1 102
LCR2 102
LCR3 102
LCR4 102
LCR5 103
LCR6 104
LCR7 105
LCR8 105
LCR9 105
LCR10 106
17
LCS | Stairs
LCS1 107
LCS2 108
LCS3 108
LCS4 108
LCS5 109
LCS6 109
LCS7 110
LCS8 110
LCS9 111
LCS10 111
LCS11 112
LCS12 113
LCS13 112
LCS14 114
18
LCH6 118
LCH7 118
LCH8 118
LCH9 118
LCE | elevators
LCE1 119
LCE2 119
LCE3 120
LCE4 121
LCE5 122
LCE6 123
LCE7 123
LCE8 124
LCE9 124
LCE10 123
LCE11 125
LCE12 125
LCE13 125
LCE14 125
LCE15 126
LCE16 127
LCE17 128
19
LCE18 129
LCE19 129
LCE20 129
LCE21 130
LCE22 129
LCE23 131
LCE24 131
20
LCEs3 135
LCEs4 136
21
SPpt17 146
SPpt18 147
SPpt19 148
SPpt20 148
SPpt21 149
SPpt22 149
22
SPgb | Grab bars in accessible toilets
SPgb1 156
SPgb2 156
SPgb3 157
SPgb4 157
SPgb5 158-159
SPgb6 158-159
SPgb7 160
SPgb8 161
SPgb9 161
23
SPff | Full family toilet
SPff1 166
SPff2 166
SPff3 166
SPff4 166
SPff5 166
24
CHR | CHANGING ROOMS Page NO.
FUt | Tables
FU1 177-179/181
FUt1 177
FUt2 177
FUt3 177
FUt4 178
25
FUbc4 179
FUbc5 179
FUbc6 180
26
FUv | Vending machines and ATM’s, if provided
FUv1 185
FUv2 185
FUv3 186
FUv4 186
FUv5 186
FUv6 187
FUv7 188
FUv8 189
FUv9 189
FUv10 189
FUv11 187
FUb | Bollards, planters, telephone booths and other furniture elements, if provided
FUb1 190-191
27
FCk5 192-193
FCk6 192-193
28
HE | Hearing Enhancement Page NO.
ARh | Rooms
ARh1 209
ARh2 209
29
ARh3 209
ARh4 210
ARh5 210
ARh6 211
ARh7 211
ARh8 212
ARh9 209
ARh10 212
ARh11 213
ARh12 211
30
G | General Page NO.
GD | Doors
GD1 219
GD2 219
GD3 219
GD4 219
GD5 220
GD6 221
GD7 221
GD8 222
GD9 222
GD10 223
GD11 224
GD12 225
GD13 226
GD14 227
GD15 227
GD16 228
31
GW | Windows
GW1 229
GW2 230
GW3 229
GW4 229
GW5 229
GS | Switches
GS1 231
GS2 231
GS3 231
GG | Glass Surfaces
GG1 232-233
GG2 232-233
GG3 232-233
32
GR | Restaurant terraces
GR1 236
GR2 236
GR3 236
GR4 236
GR5 236
33
GBs | Bus signpost
GBs1 241
GBs2 241
GBs3 241
GBs4 241
GBs5 242
34
GS | Storage facilities and lockers
GS1 246
GS2 246
GS3 246
GS4 246
GB | General Balconies
GB1 248
GB2 248
GB3 248
GB4 248
35
GAU5 251
GAU6 252
GAU7 252
GAU8 253
GAU9 253
GAU10 253
GAU11 253
36
GWA | Wayfnding
GWA1 258
GWA2 259
GWA3 259
GWA4 259
GWA5 260
GWA6 260
GWA7 261
GWA8 265
GWA9 262
GWA10 263-264
GWA11 265
GWA12 265
GWA13 262
GWA14 266
GWA15 266
GWA16 267
GWA17 268
GWA18 269
GWA19 269
GWA20 270-271
GWA21 272
37
38
Entrance
E Entrance
≤5%
E1
Entrance
41
E Entrance
E2
Inaccessible path
E2
Accessible path
E2 When several paths, both accessible and inaccessible marked with directional sign
42 Entrance
E Entrance
E3
E3 If accessible door not the main door, it is marked with directional sign
Entrance
43
E Entrance
E4 Section A-A
±2mm
E3 E9
E3 If accessible door not the main door, it is marked with directional sign
44 Entrance
E Entrance
E3
E4
±2mm
E9
E3 If accessible door not the main door, it is marked with directional sign
Entrance
45
E Entrance
E7
≥ 900mm
2200mm
E6
E7 Automatic door
46 Entrance
E Entrance
E8 ≥5 seconds
remaining open
<66N ≥3 seconds to
fully open
≥3 seconds to
fully closed
E8 3 seconds or more to move from closed to fully open position - Remain fully open for a minimum 5 seconds - Force not more than 66N
Entrance
47
E Entrance
≥900mm
E10
E10 Access controls barriers with at least one barrier with width ≥900mm if provided
48 Entrance
E Entrance: In Parks & Where Required
E11
Max 1750mm
Min 1250mm
1000mm
E11
E11 Tactile map located at the main entrance near the door on the right side within 1000mm
Entrance
49
E Entrance: In Mosques
E13
E14
E15
E12
E13
E14
E12 A clear Area provided at the entrance to prevent shoes E14 Seats provided at the entrance toilets ablution areas and at other
from blocking the accessible path locations where people are required to remove their shoes
E13 keep clear mat in front the entrance E15 An accessible entrance is provided
50 Entrance
EGT Entrance - Guiding Tactile Pavements
ER1 EGT1
Section B-B
EGT2
EGT3
Entrance
51
EGT Entrance - Guiding Tactile Pavements
32mm
40mm
≥400mm
EGT2
40mm
30mm
4mm
Section B-B
EGT3 EGT4
52 Entrance
ER Entrance - Counters And Reception Areas
865mm ER1
1420mm
Entrance
53
ER Entrance - Counters And Reception Areas
750-790mm
≥680mm ER4
480mm
ER2
54 Entrance
ER Entrance - Counters And Reception Areas
750-790mm
ER3
950-1250mm
ER3
≥680mm
ER3 Low counter height between 750-790mm & high counter height between 950-1250mm
Entrance
55
ER Entrance - Counters And Reception Areas
ER5
ER6
ER5 When required, hearing enhancement systems using induction loop, infrared and radio frequency are provided
ER6 With international symbol if access for hearing loss
56 Entrance
Entrance - Counters And Reception Entrance
Areas 57
Path
58 Path
PE Path - Accessible Path Of Travel –External
Furnishing zone
Li
PE2
ne
ar
an
d
co
nt
in
ue
d
Accessible Path
≥1800mm
PE1
Frontage
zone
PE1 1800mm width without obstacle, from the parking to the entrance, segregated from traffc circulation
PE2 Linear and continued
Path
59
PE Path - Accessible Path Of Travel –External
PE3
60 Path
PE Path - Accessible Path Of Travel –External
≥2200mm
PE5
Accessible Path
PE4
Slope ≤5%
Slope ≤2%
PE14
Path
61
PE Path - Accessible Path Of Travel –External
PE7
<100mm
<100mm
PE7
Accessible Path
Accessible Path
62 Path
PE Path - Accessible Path Of Travel –External
>100mm
Path
63
PE Path - Accessible Path Of Travel –External
Ø 50mm
Ø 80mm
Ø 160mm
Ø 250mm
Ø 340mm
Ø 420mm
900mm
800mm Ø 500mm
600mm
500mm
400mm
300mm
64 Path
PE Path - Accessible Path Of Travel –External
PE9
Accessible Path
Path
65
PE Path - Accessible Path Of Travel –External
PE10
66 Path
PE Path - Accessible Path Of Travel –External
PE11
Accessible Path
Furnishing Zone
PE11 Free of obstacles and located between the building’s façade and the furniture zone
Path
67
PE Path - Accessible Path Of Travel –External
Road Way
Parking
Frontage zone
Furnishing zone
68 Path
PE Path - Accessible Path Of Travel –External
PE12
Acce
ssible
th
pa
path
le
sib
Max 5%
es
c
Ac
Max 5%
Max 5%
Min 1800mm
Min 1800mm
PE12 Parking entrance do not modify the slope or width of the accessible path
Path
69
PE Path - Accessible Path Of Travel –External
PE14
Max 2%
Max 2%
Height ≥100mm ≤150mm
PE14
PE13
Section X - X
PE13 Curb height between 100mm and 150mm PE14 Cross Slope Gradient ≤2%
70 Path
PE Path - Accessible Path Of Travel –External
PE15
Elevator
Path
71
Pbs Path And Beach Services
Pbs4
≤1500mm
≤2%
≥1500mm
Pbs2 ≤5%
Accessible path
Pbs1
Pbs3
Pbs8
Pbs1 Width ≥1500mm Pbs2 Longitudinal gradient ≤5% and cross gradient ≤2%
Pbs3 Suitable for walking barefoot with low heat transmission Pbs4 Public toilets near accessible path and the car parks
Pbs8 With accessible showers in beaches
72 Path
Pbs Path And Beach Services
Pbs6
Pbs8
Pbs6
Pbs5
Pbs7
Path
73
Pbs Path And Beach Services
Shower Jet
2100mm
700-1200mm
Pbs11 Pbs9
900mm
450mm
200mm
200mm
Pbs11
m
00m
≥18
Pbs10
Shower Jet
Pbs9 Shower controls height between 700-1200mm and activated with elbow
Pbs10 Shower area width ≥1800mm
Pbs11 Shower provided with armless bench rised 450mm for seat base and 900mm for the back, located at 200mm from the shower
74 Path
Pbs Path And Beach Services
Furniture zone
Cycling path
Pbs13
Pbs12
Pbs12 If there is a cycling paths it’s between urban furniture and curb
Pbs13 Pedestrian crossings are preceded by tactile warnings
Path
75
Pbs Path And Beach Services
≤8%
≤8%
≤8%
Pbs14
76 Path
Pbs Path And Beach Services
Pbs15
Max 50m
Pbs15
Pbs15
Path
77
PLg Path - Playground
PLg3
PLg1
PLg2
PLg4 PLg1
PLg2
PLg1 Floor surface of rubber or compacted sand PLg2 Smooth and soft foor surface for children play area
PLg3 ≥50% of play activities are usable by children with disabilities PLg4 Low heat transmission materials of play activities
PLg5 Materials treated to prevent electrostatic discharges and if not, should be marked with symbol with magnatic warning sign
78 Path
PF Path - Floor Surface
PF1 Slip resistance (PTV) comply: level and inclined with ≤5% dry areas indoor - (PTV) Between 15 and 35
PF2 Inclined >5% dry areas indoor, (PTV) ≥35
Path
79
PF Path - Floor Surface
PF4
th
pa
ble
ssi
ce
PF3
Ac
PF4
Slip Resistance (PTV)
Between 35 and 45
Slip Resistance
(PTV) ≥45
Acc Ramp >5%
essible
path
PF3 Level and inclined with ≤ 5% wet areas and outdoor - (PTV) Between 35 and 45
PF4 Inclined > 5% wet areas and outdoor, (PTV) ≥ 45
80 Path
PF Path - Floor Surface
e path
ssibl
Acce
Slip Resistance
(PTV) ≥45
PF5
PF5
Slip Resistance
(PTV) ≥45 PF5
Slip Resistance
(PTV) ≥45
Path
81
PF Path - Floor Surface
h
sible pat
Acces
PF6
82 Path
PF Path - Floor Surface
y≤1.25 x
PF7
PF7 Rugs and carpets are frmly fxed and do not increase the strength required to roll over a ceramic pavement by ≥25%
Path
83
PF Path - Floor Surface
PF8 PF8
PF9
PF8 Without rounded edges and excessive joints PF9 Not producing glare
84 Path
PF Path - Floor Surface
Furnishing Zone
Accessible path
Surrounding Surface
PF10
Surrounding Surface
PF10 With refectance contrast of at least 30 points LRV between accessible pavement (surrounding surface or 300mm pavement strip)
Path
85
PF Path - Floor Surface
Accessible Path
PF11
No Glare
No Excessive Heat
PF11 Lighting in foor (Flooring Light) not produces glare and excessive heat
86 Path
PF Path - Floor Surface
Accessible Path
manhole covers Accessible Path
height <5 mm Holes <5mm
PF12 PF13
PF12 Absence of utility covers (manhole covers) on the path or with height less of 5mm
PF13 Absence of drain grids on the path or with holes smaller than 5mm
Path
87
PF Path - Floor Surface
Section A-A
PF14 PF14
Min 60mm
Max 15mm
10mm
Section A-A
PF14 Change of pavement level ≤15mm, with ≤25% gradient slope (chamfered)
88 Path
PF Path - Floor Surface
th
Pa
le
sib
es
c
Ac
PF15
PF15 Longitudinal grate openings with perpendicular orientation to the pedestrians’ direction of travel
Path
89
PF Path - Floor Surface
<1800mm
PF16
th
Pa
le
ib
ss
ce
Ac
PF16 For distance between tree basin edge and the façade < 1800 mm, tree grate with walkable surface
90 Path
PI Path - Internal Corridors
1200mm
PI2
≥2200mm
≥2200mm
PI5
≥1000mm
PI1
Path
91
PI Path - Internal Corridors
PI4
PI3 Tactile warning surface in any change of level PI4 Illumination ≥60 lux
92 Path
PI Path - Internal Corridors
PI6
<100mm
PI6
>100mm
PI6
>100mm
Max 300mm
Path
93
Level
Changes
94 Level Changes
LCG Level Changes - Guardrails
3KN/m
LCG3
LCG2
≥1100mm
≥500mm
LCG1
LCG1 Absence of unprotected level changes - guardrails for heights ≥500mm LCG2 Height ≥1100mm
LCG3 With suffcient strength and stiffness to withstand horizontally uniformly distributed force of 3 KN/m
Level Changes
95
LCG Level Changes - Guardrails
LCG4
≤100mm
LCG5
LCG4 Can not be climbable LCG5 Width of horizontal and vertical openings ≤100mm
96 Level Changes
LCG Level Changes - Guardrails
900mm
650-750mm
≥100mm
LCG6
LCG6
≥100mm
Level Changes
97
LCWT Level Changes - Warning Tactile Surface
LCWT1 1000mm
LCWT1
LCWT2
Available in the beginning and end of every level change Installed along the entire width of the element
LCWT1 LCWT2
including ramps and stair landings, or any dangerous element
98 Level Changes
LCWT Level Changes - Warning Tactile Surface
LCWT1
LCWT2
LCWT1
LCWT2
LCWT1
LCWT2
LCWT1 Available in the beginning and end of every level change LCWT2 Installed along the entire width of the element
including ramps and stair landings, or any dangerous element
Level Changes
99
LCWT Level Changes - Warning Tactile Surface
300mm
LCWT4
≥300mm
LCWT3
LCWT4 Located at 300mm away from the edge of the ramp or stair fight or any dangerous element
15mm
30mm
20mm
4mm
LCWT6
300 mm
15mm
300mm LCWT5
LCWT5 Warning tactile truncated cones diameter = 30mm at bottom and 20mm at top, and protruding 4mm
LCWT6 Non glare on shiny or slippery
Level Changes
101
LCR Level Changes - Ramps
LCR2
≤8% or 1:12 >5% gradient
LCR3
LCR1 Ramps used only when gradient of level >5% LCR2 Slope is ≤8% or 1:12
LCR3 Cross fall gradient ≤2% LCR4 Run length ≤10 meters
LCR5
1000mm
900mm
650-750mm
1100mm
Level Changes
103
LCR Level Changes - Ramps
LCR6
LCR8
≤2%
1500mm
LCR8
≥1200 mm 1500mm ≤2%
LCR9 LCR7
1500 mm
1500mm
LCR7
LCR7 Landings at the beginning and end of every run -surface 1500mm x 1500mm
LCR8 Level landings or ≤2%
LCR9 Corridors in landings width ≥1200 mm width
Level Changes
105
LCR Level Changes - Ramps
≥1500mm
LCR10
≥1500mm
LCR10
LCR10 No door located at ≤1500mm from start and or end of each ramps
LCS1
LCS1 Availability of alternative elevator accompanied with internal staircase in more than one story building
Level Changes
107
LCS Level Changes - Stairs
300-340mm T
LCS3
LCS4
600mm <2R + T <650mm
R
LCS2 150-175mm
LCS2 Steps rises between 150 - 175mm LCS3 Steps stair treads between 300 - 340mm
LCS4 Steps rise (R) and Tread (T) fulfl: 600 mm <2R + T <650mm
LCS5
LCS6
Level Changes
109
LCS Level Changes - Stairs
LCS8
≤ 25mm LCS7
(refectance contrast
of 30 LRV)
LRV=30
30mm
LCS9 12
LCS10 11
10 Max
9
same height ±4mm 8
7
6
5
same height ±4mm
4
3
2 Min
same height ±4mm 1
LCS9 Steps with same height with a ±4mm tolerance LCS10 Stair fights steps number between 3 and 12
Level Changes
111
LCS Level Changes - Stairs
Stairs width = X
≥1100 mm
≥1200mm
LCS11
X≥1200 mm
LCS11 Usable stair fight width ≥1100mm LCS13 Landing with same width of stair and a length ≥1200 mm
LCS12
≥200lux
≥200lux
≥200lux
Level Changes
113
LCS Level Changes - Stairs
≥2200mm
LCS14
≥700mm
LCS14 Empty space with height <2200mm under the stair is protected
300mm
LCH1
2100 mm
300mm At most
LCH2
2100 mm
900mm At most
650-750mm
Level Changes
115
LCH Level Changes - Handrail for ramp and stairs
LCH4 900 mm
650-750 mm
LCH3
650-750 mm 900 mm
LCH4 LCH3
1000mm
LCH5
Level Changes
117
LCH Level Changes - Handrail for ramp and stairs
LCH6
LCH6
≥ 40 mm
LCH8
Contrast of 30 LRV
against its background
LCH7
30-40 mm
LCH9
LCH6 Rounded section of 30 - 40 mm separated from the LCH7 Handrails designed to allow continuity of gripping
wall with a distance ≥40mm without interfering its mounting system
LCH8 Contrast of 30 LRV against its background LCH9 Handrails made of comfortable materials against heat and
coldness
Second Floor
LCE1
First Floor
LCE2
Ground Floor
LCE1 Present in buildings with more than one foor LCE2 Accessible from ground foor in public areas
Level Changes
119
LCE Level Changes - Elevators
LCE3 LCE3 00
mm
15
15
00
m
0m
m
m
m
0
LCE3
m
12
15
15
00
00
00
12
m
m
m
m
LCE3 Dimensions shall comply: One door ≥1200 x 1500mm - Two opposing doors ≥1200 x 1500mm
- Two doors in 90° ≥1500 x 1500mm
≥900mm
≥900mm
LCE4
LCE4 Automatic doors with a width of 900 mm and colour contrast against walls
Level Changes
121
LCE Level Changes - Elevators
LCE5
1500mm
1500mm
Max 300mm
LCE7
1830mm
Min 900mm LCE10
Max 1200mm
1830mm
LCE7
1200mm
900mm
LCE6
LCE6 Elevator calling buttons height between 900 - 1200mm LCE7 Floor indicator located at 1830mm
Level Changes
123
LCE Level Changes - Elevators
LCE8
LCE9
LCE8 Only one mirror inside the cabin on the wall opposite to the door over the handrail level
LCE9 Inside the cabin, minimum two handrails at a height of 800 mm to 1000mm from the foor
LCE13
LCE12
LCE11
≥ 3 mm
LCE14
LCE11 The ground foor button protruded ≥3mm distinguished with a green color
LCE12 Call buttons distinguished with icons and color contrast against background
LCE13 Buttons provide two-channel feedback/ visual & acoustic OR visual & tactile
LCE14 Emergency phone number is indicated by graphic and tactile
Level Changes
125
LCE Level Changes - Elevators
LCE15 LCE15
100 Lux
LCE16
Level Changes
127
LCE Level Changes - Elevators
LCE17
opaque
3 Seconds
LCE18 LCE18
1500mm
LCE22 LCE19
LCE18 Automatic doors open at least 3 seconds LCE19 Doors provided with sensors at two levels open automatically
LCE20 Door force less than 135N LCE22 Braille & tactile signage on the door jamb at 1500mm height
Level Changes
129
LCE Level Changes - Elevators
LCE21
LCE21
LCE21 Indication sign of accessible elevator direction when various options of vertical circulation
Second foor
First foor
LCE24
LCE23
Ground foor
Level Changes
131
LCL Level Changes - Lift Platform, If Provided
700-1200mm
LCL3
LCL2
1500mm 1500mm
900mm
LCL4 LCL8
LCL7
Min 1500mm
Min
LCL1 900mm
LCL1
Level Changes
133
LCL Level Changes - Lift Platform, If Provided
LCL5
LCL9
800-1000mm
Full cabin max 4000mm
Open cabin max 2000mm LCL6
LCL5 Cabin with side protections to isolate users from side walls
LCL6 Inside the cabin, minimum two handrails at a height of 800mm to 1000mm from the foor
LCL9 2000mm travel height if open cabin- 4000mm height if full cabin
LCEs2
≤5%
LCEs1
LCEs3
LCEs2
Level Changes
135
LCEs Level Changes - Escalators, Travellators and Mechanical Ramps
LCEs4
LCEs4
Audio system indicating start
and end
SPpt1 SPpt1
Sanitary Provisions
139
SPpt Sanitary Provisions - Public Toilet
Public Toilet
Public Toilet
150m
SPpt2
SPpt5
0mm
900-120
SPpt4
SPpt3
Sanitary Provisions
141
SPpt Sanitary Provisions - Public Toilet
1100-1400mm
SPpt8
SPpt7 900-1200mm
900mm
SPpt6
500mm
SPpt11
SPpt10
400mm
SPpt12
1200mm
700mm
300mm
SPpt9
SPpt9 If 2 or more urinals, 1 with usable height at 300mm and with grab bars
SPpt10 Flushing systems are operated by pressing or with a fush handle with large surface and operable with one hand or elbow
SPpt11 Distance between the grab bars is 500mm
SPpt12 Grab bars mounted between 700mm from bottom up to 1200mm height
Sanitary Provisions
143
SPpt Sanitary Provisions - Public Toilet
SPpt13
(PTV) ≥45
SPpt14
SPpt15
SPpt14 Non slippery foor surface with Pendulum Test Value (PTV) ≥45
SPpt15 With wash basins in a row, 1 is accessible
Sanitary Provisions
145
SPpt Sanitary Provisions - Public Toilet
≥700mm
≥250
mm SPpt16
800-850mm
≥700mm SPpt17
SPpt16 Accessible wash basin clearance from ground surface space ≥700mm high and ≥250mm deep
SPpt17 Usable wash basin surface top height between 800 - 850mm
or
or
SPpt18
SPpt18 Faucets (water tap) operated by pressing button or a lever handle or with a sensor ( Not turning valve)
Sanitary Provisions
147
SPpt Sanitary Provisions - Public Toilet
<600mm
900-1200mm
SPpt19 ≤900mm
SPpt20
SPpt19 Distance to the faucet ( water tap) shall be less than 600mm and vertical between 900mm and 1200mm.
SPpt20 Lower edge of mirror ≤900mm height
SPpt22
Max 1200mm
SPpt21
Min 700mm
SPpt21 Controls and accessories height (soap dispenser, dryer) mounted at height 700 - 1200mm
SPpt22 Advisory signs indicating safety procedures and other regulatory information
Sanitary Provisions
149
SPat Sanitary Provisions - Accessible Toilet
SPat1
SPat1
SPat1 One accessible toilet for each gender in every foor or 1 independent accessible toilet for both genders
Accessible Toilet
Accessible Toilet
150m
SPat2
SPat2 One accessible toilet within a 150m distance from any part of the building
Sanitary Provisions
151
SPat Sanitary Provisions - Accessible Toilet
SPat4
1200mm
Min 1500mm
SPat3
700mm
SPat5
Min 1500mm SPat6
Sanitary Provisions
153
SPat Sanitary Provisions - Accessible Toilet
1420mm
SPat7
865
865 865
SPat8
1420mm
1420mm
865
1420mm
SPat7 Lateral interaction space on both sides of the toilet or on one side if symmetrical units
SPat8 Lateral interaction space size 865mm x 1420mm
in Out
in
300m
300m
Min 300m 300m
900-1200mm
1100-1200mm
900-1000mm SPat10 SPat11
SPat12
SPat9
Sanitary Provisions
155
SPgb Sanitary Provisions - Grab Bars in Accessible Toilet
1KN
1KN
1KN
SPgb2 ≥45mm
SPgb1
SPgb1 The space between grab bars and the wall ≥45mm SPgb2 Withstand a force of 1 kN in any direction
SPgb3
700mm
30-40mm
700 - 750mm
SPgb4
Sanitary Provisions
157
SPgb Sanitary Provisions - Grab Bars in Accessible Toilet
SPgb5
1500mm
670-700mm
SPgb6
SPgb5
SPgb5
670-700mm
Min1500mm
SPgb6
Sanitary Provisions
159
SPgb Sanitary Provisions - Grab Bars in Accessible Toilet
300mm
300mm
SPgb7
SPgb7
700mm
700-750mm
SPgb7 With one transfer area, horizontal bars mounted in wall 300mm from the sanitary edge with 700mm length
and mounted 700 - 750mm
700mm
SPgb8
Min 600mm
450-500mm
700-750mm
SPgb9
SPgb8 600mm vertical bar mounted 700 - 750mm from ground away 700mm from the wall
SPgb9 Toilet height between 450 - 500 mm
Sanitary Provisions
161
SPsh Sanitary Provisions - Shower, If Provided
≤4%
SPsh1
SPsh2
SPsh1 Shower foor surface at same foor level with surrounding area
SPsh2 Drain water slope ≤4%
SPsh3
Min 865mm
Min 1200mm
Min 400mm
SPsh3
Min 400mm
SPsh3 Dimensions of showers area at least 865 x 1200mm and a seat of at least 400 x 400mm
Sanitary Provisions
163
SPsh Sanitary Provisions - Shower, If Provided
670-700mm
SPsh7
150-200mm
SPsh4
800mm
SPsh6
800mm
SPsh5
700-750mm
800mm
SPsh4
450-500mm
150-200mm
SPsh4 Seat located at a height between 450 - 500mm and separated from the wall between 150 - 200mm
SPsh5 Horizontal bar length 800mm mounted 700 - 750mm from the ground
SPsh6 Two Vertical bars length of 800mm in the lateral wall of the shower seat mounted 800mm from the foor level
SPsh7 Distance between vertical bars between 670 - 700mm
900mm
Max 500mm
SPsh8
Sanitary Provisions
165
SPFF Sanitary Provisions - Full family Toilet
SPff5
300mm
500mm
SPff2 SPff4
500mm
2000mm
SPff3 SPff1
SPff1 With a folding adult changing board, SPff2 Additional children wash basin at SPff3 Maneuvering turning space of at
at height of 500mm from the foor a height of 500mm least 2000mm diameter
SPff4 With a urinal with usable height of 300mm SPff5 With emergency call button or rope
SPfe3
SPfe4
SPfe4
SPfe2
SPfe3
SPfe2
Sanitary Provisions
167
SPfe Sanitary Provisions - Feeding Room
SPfe4
SPfe3
SPfe2 SPfe2
SPab1
Sanitary Provisions
169
SPab Sanitary Provisions - Ablution Areas, If Provided
SPab6
1200mm
≥30LRV
SPab7
SPab2
SPab2 One accessible ablution unit linked to an accessible path. The closest from the entrance
SPab6 Approaching free space of 1200mm
SPab7 The approaching free space with contrast ≥30 points LRV
200mm
SPab4
Max 1200mm
Min 700mm
700-800mm Max 1200mm
Min 700mm
SPab3
SPab3 Two horizontal bars mounted between 700 - 800mm with the same length of wash basin
SPab4 All Accessories at a height between 700 - 1200mm
Sanitary Provisions
171
SPab Sanitary Provisions - Ablution Areas, If Provided
SPab5
CHR1
1500mm
≥ 1000mm
1500mm
CHR1
1420mm CHR2
CHR1 865
≥1000mm CHR1
1420mm
1500mm
CHR1
CHR1 Corridors width ≥1000mm and direction changes with manoeuvring turning space of 1500mm
CHR2 Approaching space for lockers, benches and furniture 1420 x 865mm
CHR3 1 of 10 showers is accessible, if provided
CHR4 1 of 10 toilet is accessible, if provided
Changing Rooms
175
Furniture
176 Furniture
FUt Furniture - Tables
≥480mm
FUt3
≤800 mm ≥680mm ≤800 mm
≥680mm
FUt1 FUt2 FUt1
FUt2
FU1 Without sharp edges, protruding FUt1 Height of the top ≤800 mm
FUt2 Clearance height under the table ≥680mm FUt3 Clearance depth under the table ≥480mm
Furniture
177
FUt Furniture - Tables
FUt4
178 Furniture
FUbc Furniture - Benches and Chairs
FUbc3
400 - 460mm
400 - 450mm
FUbc2
430mm ± 30mm
FUbc1 FUbc4
1420mm
865mm
FUbc5
FU1 Without sharp edges, protruding FUbc1 Seat height of 430mm with a ± 30mm tolerance
FUbc2 Seat depth between 400 - 450mm FUbc3 With backrest height between 400 - 460mm FUbc4 Some seats with armrests
FUbc5 At least in one side has lateral interaction spacem for wheelchair min 865 x 1420mm with international symbol
Furniture
179
FUbc Furniture - Benches and Chairs
50m
100m
FUbc6
FUbc6
50meters
FUbc6 Outdoor spaces - benches every 100meters accompanied with shaded areas every 50meters
In buildings - benches or seat types every 50meters
180 Furniture
FUd Furniture - Drinking Fountains, If Provided
FUd6
FUd5
Max 1200mm
FUd3
≤ 915mm
≥ 700mm
600-900mm
FUd1
Min 700mm
FUd4
FUd3
FUd2 FUd2
FU1 Without Sharpe edges, protruding . FUd4 Water supply between 600 - 900mm height
FUd1 Two fountains with different heights ≤915mm for FUd5 With bottle fller
the lower one with leg clearance
FUd6 Clearly visible with contrasting background
FUd2 Comfortable frontal and lateral approach
FUd3 If manual button, minimum height = 700mm for the lower one
and maximum 1200mm for the higher one
Furniture
181
FUb Furniture - Trash Bins, If Provided
FUb3
≤900 mm
Accessible P
ath
m
FUb2
m
20
FUb1
14
865
mm
FUb1 Not located in the accessible path FUb2 Lateral space of interaction of at least 865 x 1420mm
FUb3 Trash bin opening height ≤900mm
182 Furniture
FUb Furniture - Trash Bins, If Provided
Max 50 Meters
FUb4
Furniture
183
FUb Furniture - Trash Bins, If Provided
Push Button
FUb6
FUb7
≤ 250mm
FUb5
FUb7
184 Furniture
FUv Furniture - Vending Machine And ATM, If Provided
FUv2
≤2%
1420mm
865mm
FUv1
Furniture
185
FUv Furniture - Vending Machine And ATM, If Provided
FUv4
≥600mm
Max 1200mm
1000mm
Min 400mm
FUv3
FUv5
FUv3 Screen and keyboard are visible from a point located 1000mm above the foor
FUv4 Screen and keyboard with no refection or glare
FUv5 Control buttons height between 400 - 1200mm and ≥600mm from any corner if exist
186 Furniture
FUv Furniture - Vending Machine And ATM, If Provided
FUv11
FUv6
FUv6 Control buttons with high embossed text and braille FUv11 Slots are wide and have a funnel effect
Furniture
187
FUv Furniture - Vending Machine And ATM, If Provided
FUv7
800 - 1200mm
800 - 1200mm
800 - 1200mm
188 Furniture
FUv Furniture - Vending Machine And ATM, If Provided
FUv10
FUv9 FUv10
FUv8
FUv8 Visual and acoustic indication system and alarm system provided
FUv9 Audio information provided
FUv10 CCTV intercom provided
Furniture
189
FUb Furniture - Bollards, planters, telephone booths and other furniture elements, if provided
≥1200mm
≥1200mm
th
Pa
le
sib
es
c
Ac
≥1200mm
FUb1 ≥1200mm
FUb1 Outside the accessible path or do not reduce accessible path ≤1200mm
190 Furniture
FUb Furniture - Bollards, planters, telephone booths and other furniture elements, if provided
th
Pa
le
sib
es
c
Ac
FUb1
FUb1 Outside the accessible path or do not reduce accessible path ≤1200mm
Furniture
191
FCK Furniture - Commercial Kiosk: Lateral Interaction
FCK2
FCK6
Max 1200mm
FCK5 700-790mm
FCK1
1420mm 865
th
Pa
le
sib
c es
Ac
FCK3
Customer counter with lateral or frontal interaction space Equipped with hearing enhancement system and
FCK1 FCK4
865 x 1420mm indicating post
FCK2 With pargola in the front side for outdoor FCK5 Controls at height of 1200mm
FCK3 Linked to an accessible path FCK6 Audio and Visual information provided
192 Furniture
FCK Furniture - Commercial Kiosk: Frontal Interaction
FCK2
FCK6
Max 1200mm
FCK5
700-790mm
Path
ible FCK1
Access
FCK3 865
Customer counter with lateral or frontal interaction space Equipped with hearing enhancement system and
FCK1 FCK4
865 x 1420mm indicating post
FCK2 With pargola in the front side for outdoor FCK5 Controls at height of 1200mm
FCK3 Linked to an accessible path FCK6 Audio and Visual information provided
Furniture
193
Parking and
drop off point
PA1
<50m
PA3
PA2 Number of accessible parking lots: 2% of the Total Parking, max 10 spots
PA3 Accessible spaces as close as possible to the entrance of the building and no more than 50m
2200mm
Max 8% PA4
Max 8% 0mm
550 2200mm
≥
Max 8% PA6
25
00
m
m
PA7
PA5
≥
12
00
m
m
PA4 Dimensions of accessible parking spaces: PA6 Signs mounted at 2200mm with international symbol
2500 x 5500mm for angled parking,
2600 x 6000mm for parking along the sidewalk PA7 Marked with international symbols
2200 mm
2200mm
8%
8% 8%
Min 2600mm
mm
00
55
250
0mm Min
6000m
m
≥12 ≥12
00m 00m
m m
PA4 Dimensions of accessible parking spaces: PA6 Signs mounted at 2200mm with international symbol
2500 x 5500mm for angled parking,
2600 x 6000mm for parking along the sidewalk PA7 Marked with international symbols
PA5 With lateral access aisle ≥1200mm PA8 Curb cut with maximum 8% slope
Two Wheelchairs
(Reserved Spaces)
50 Seats
50 Seats
RS1
Two Wheelchairs
(Reserved Spaces)
RS1 Number of reserved seats: one reserved wheelchair space for every 50 seats or fraction thereof and beyond 500 seats, one more every
100 seats of fraction thereof , as on general checklist GAU
HE1
HE6
HE1 Hearing enhancement system is provided in the service countres and assembly areas
HE6 International symbol of access for hearing loss is provided, when the system is provided for persons with hearing impairment
Hearing Enhancement
203
HE Hearing Enhancement
HE2
HE2 Hearing enhancement system is provided in the meeting rooms serving more than 25 person
HE3 Hearing enhancement system provided in the auditoriums and theaters
HE4 Posted sign to indicate that the enhancement system is available
HE5 Compatible with language translation system
HE7 Induction loop provided when acoustic information is provided
MD4
Max 1m
MD4
MD3
Sensorial elements used to assist visitors to preceive the informations through different sences,
MD1
like lights, smells, soundes, colours and others.
MD2 Audio guides provided to explain, guide and assist the visitors
MD3 Displays are visible at amaximim height of 1 m
MD4 Signage of at least 14 pt and well illuminated
1500mm 1500mm
Accessible Room
209
ARh Accessible Room - Hotel Rooms
≥200 Lux
ARh5
1500mm
1500mm
ARh4
1500mm
ARh4 Clear route & 1500 x 1500mm free space beside the bed ARh5 Illumination ≥200 lux
ARh6
700-1200mm
400-1000mm
ARh7
800-1000mm
ARh12
ARh6 Controls placed at height between 700 - 1200mm ARh7 Electronic outlets at height between 400 - 1000mm
ARh12 Viewing device provided in the door at height 800 - 1000mm
Accessible Room
211
ARh Accessible Room - Hotel Rooms
ARh10
≤500mm ARh8
ARh8 The bed height ≤500mm ARh10 Dressing mirror provided with front space up to 2000mm
700-1200mm
ARh11
1200mm
ARh11 Shelves and drawers are provided between 700 -1200mm from the foor and clothes hanger placed at height 1200mm
Accessible Room
213
ARd Accessible Room - Dining Rooms
≤ 800 mm
FUt1
≥ 680mm
FUt2
m
00m
ARd6
9
Min
Min 90
FUt3 ARd4 0mm
Min 90
mm
≤ 800 mm
0mm
≥ 680mm
≥ 480mm
m
Min 90
FUt1 ARd1
00
00m
0mm
Min 9
9
Min
FUt2 Min 9
00mm
ARd1 Accessible path of travel provided to half of dining area (900mm minimum)
ARd4 10% of the tables shall comply with the dimensional criteria for tables
ARd6 Minimum 900mm clear passage to all food service area
ARd2
≥100 lux
Accessible Room
215
ARd Accessible Room - Dining Rooms
900-1200mm
ARd5 Min 900mm
Min 900mm
Min 900mm
Min 900mm
ARd6
ARd1
ARd1 Accessible path of travel provided to half of dining area (900mm minimum)
ARd5 The self service tables height located between 900 - 1200mm from the foor)
ARd6 Minimum 900mm clear passage to all food service area
Min 900mm
ARd1
ARd1
Min 900mm
Min 900mm
ARd7
ARd1 Accessible path of travel provided to half of dining area (900mm minimum)
ARd7 Spaces for children strollers and mobility devices are provided, 10 seats are movable
Accessible Room
217
General
218 General
GD General - Doors
≥900mm 40mm
GD1 GD3
GD2
900-1200mm
GD4
General
219
GD General - Doors
GD5
GD5
220 General
GD General - Doors
≤25 N
GD6
GD7
90°
General
221
GD General - Doors
GD8
250mm
GD9
222 General
GD General - Doors
GD10
Revolving door
Alternative door
General
223
GD General - Doors
600
30
0m mm
m
15
m
12 00
m
00 mm
00
m mm
15
m 0
20
1 GD11
224 General
GD General - Doors
300
mm
12
00
mm
m
0m
GD12 120
General
225
GD General - Doors
300mm 300mm
1200mm 1200mm
226 General
GD General - Doors
1200mm
1200mm
GD15
m
1500m
m
1500m
GD15 If two aligned doors in a series - minimum space of 1200mm x 1200mm clear between them
General
227
GD General - Doors
1200mm
1500mm
GD16
300mm
GD16 If two angled doors in a series - minimum space of 1200mm x1500mm clear between them
228 General
GW General - Windows
GW1
≥2200 mm ≥ 1200mm
GW5
Max 900mm
1200mm <1200mm
GW4
GW3
GW1 Without projections ≤2200 mm into the pedestrian area GW3 Fixed glazing at maximum of 900mm height
GW4 Operable window at 1200mm height GW5 With guardrails if window opening <1200mm
General
229
GW General - Windows
GW2
GW2
230 General
GS General - Switches
≥600mm
GS2
GS1
900-1200mm
GS3
GS1 Located between 900 – 1200mm height and located ≥600mm from any corner
GS2 Switch plates with contrast of 30 LRV against its background
GS3 Switches can be activated with the elbow
General
231
GG General - Glass Surfaces: Surfaces:Glass Surfaces more than 500mm width or 850mm height
GG1
100mm
GG2
100mm
Max 1000mm
Min 850mm
m
m
Max 1600m
Min 140 0 m
GG3
GG1 Glazed surfaces are identifed clearly from adjacent doors or other openings
GG2 Presence of two horizontal bands of 100mm width with color of 50 LRV or any other pattern or
design occupy 50% of the area between 850 - 1600mm, without empty space bigger than 500mm wide
GG3 First horizontal band height between 1400 - 1600mm from the ground level
Second horizontal band height between 850 - 1000mm from ground level
232 General
GG General - Glass Surfaces: Surfaces:Glass Surfaces more than 500mm width or 850mm height
GG1
GG2
Max 1600mm
Min 850mm
GG3
GG1 Glazed surfaces are identifed clearly from adjacent doors or other openings
GG2 Presence of two horizontal bands of 100mm width with color of 50 LRV or any other pattern or
design occupy 50% of the area between 850 - 1600mm, without empty space bigger than 500mm wide
GG3 First horizontal band height between 1400 - 1600mm from the ground level
Second horizontal band height between 850 - 1000mm from ground level
General
233
GM General - Mailbox,Garbage,Parking meters and Recycling containers
Garbage Container
>500m
Tactile Mark
<25N
GM3
<25N
700 - 1200 mm
GM2
GM1
1420mm 865mm
234 General
GM General - Mailbox,Garbage,Parking meters and Recycling containers
Mailboxes
Parking Meters
≥700mm
GM1
GM1
865mm
1420mm
1420mm 865mm
General
235
GR General - Restaurant terraces
Road
≥ 2200mm
GR5 ≥ 900mm GR3
GR1 No invading accessible path and headroom GR4 Accessible path ≥ 2000mm adjacent to the restaurant terraces
GR2 No interruption of guidance elements GR5 Bollards between terraces and road every 1200 mm
GR3 Protected by continuous element unless all features height ≥ 900mm
236 General
GBsh General - Bus Shelters
GBsh1
GBsh6
GBsh5 GBsh11
≥2200mm
GBsh4
Ac 200
ce m
≥1
ss m
ib
le
Pa
GBsh2
h t
≥120
0mm
GBsh2
GBsh1 Not invading accessible path GBsh5 No obstacles between shelter and access to bus
GBsh2 With a free of protruding obstacles path GBsh6 Glazed walls with indication and warning marks, if provided
in both sides of at least 1200mm width
GBsh11 Boarding area platform with tactile warning surface
GBsh4 Height ≥2200mm
General
237
GBsh General - Bus Shelters
GBsh6
≥1500mm
GBsh3
GBsh11
238 General
GBsh General - Bus Shelters
GBsh8
400 - 450mm
400 - 460mm
400 - 460mm
GBsh7
GBsh7 With fxed bench + seat height 400 - 460mm, depth from 400 - 450mm, backrest ≥400mm
GBsh8 With armrest on one of its side
General
239
GBsh General - Bus Shelters
GBsh10
≥200mm
≥50 lux
700 - 750mm
GBsh9
GBsh9 With standing support (perch seat) of height between 700 - 750mm and separated ≥200 mm from wall
GBsh10 Average illumination ≥50 lux, and ≥100 lux at boarding time
240 General
GBs General - Bus Signpost
GBs1
Acce 1200-1600mm
ssible P
ath GBs4
2200mm GBs2 ≥12
00m
GBs3 m
GBs2
GBs1 Sign post provided GBs2 Not obstructing the accessible path
GBs3 Clearance height ≥2200mm without protruding GBs4 Bus information height between 1200 - 1600mm
General
241
GBs General - Bus Signpost
GBs5
≥140mm
1200-1600mm
Acce
ssible
Path
≥120
0mm
GBs5 Bus line identifcation number with text height ≥140mm and Tactile
242 General
GAE General - Alarms And Means Of Egress
30 Flashes
per second
GAE3
GAE1
GAE3 GAE2
GAE6
GAE5
GAE1 Audio and visual emergency alarms provided GAE2 Visual Emergency alarm with 30 fashes per second
GAE3 Accessible means of egress signage
GAE5 Procedures for evacuation building including procedures for persons with activity limitation are posted
GAE6 Procedures posted in 14 pt San serif font
General
243
GAE General - Alarms And Means Of Egress
GAE7
GAE8
GAE7
GAE8
Other evacuation solutions for persons with activity limitation with assistance of
GAE7
an evacuation devices including protected elevator or chair
GAE8 Evacuation devices or chair are provided in every foor located near the evacuation stairwell
GAE9 Fire personnal and persons with activity limitation are trained to use evacuation devices
244 General
GGe General - Gender Equality
GGe1
GGe1
GGe1 In case of segregated use by gender, same level of accessibility for both genders
General
245
GS General - Storage Facilities and lookers
15
GS3 00
mm
GS1
14
20
m
865m
mm
GS2
0 1200mm
≥100
0mm 600m
150
GS4
GS3
246 General
GF General - First Aid Facilities
GF2
th
Pa e
ibl
ss
ce
GF1
Ac
General
247
GB General - Balconies
Min 1500mm
GB4
GB1
≥9
00
Min
mm
1
500
mm
Exterior Interior
Same Level
GB3
GB2
≤20mm Chamfer
≤10mm
248 General
GAU General - Auditorium Seating spaces
Accessible Path
GAU1
Accessible Path
GAU1
Accessible Path
GAU1
GAU1 Connected to accessible path, and accessible seatings places are permenantly provided or removable seats
General
249
GAU General - Auditorium Seating spaces
86
0m
150
5m
mm
1420
86
m
5m
m
GAU2 GAU2
GAU2 Dimension of wheelchair seating space 865 x 1420mm if frontally approached or 865 x 1500mm if laterally approached
250 General
GAU General - Auditorium Seating spaces
GAU3 m
00m
15 Level ≤1% slope
General
251
GAU General - Auditorium Seating spaces
GAU6
Two Wheelchairs
50 Seats
50 Seats
GAU6 Wheelchair spaces are arranged into groups of two spaces with equal numbers of fxed seats in every group row
GAU7 Number of reserved seats: one reserved wheelchair space for every 50 seats or fraction thereof
and beyond 500 seats, one more every 100 seats of fraction thereof
252 General
GAU General - Auditorium Seating spaces
GAU11
GAU8
GAU9
GAU10
GAU8 Clearly visible space for sign language interpreter with overhead light
GAU9 Designated accessible seats for people with hearing impairments in front of the sign language interpreter
GAU10 Aisle seats and its adjacent have foldable armrests
GAU11 Some seats have spaces to serve pets
General
253
GST General - Stage And Backstage
GST1
GST1
254 General
GST General - Stage And Backstage
GST2
General
255
GSW General - Swimming Pools
Min 1500 mm
GSW1 Min 1500 mm
GSW2
≥ 1500 mm
Slip Resistance:
(PTV) ≥ 45
GSW1
GSW5
256 General
GSW General - Swimming Pools
GSW4
GSW2
GSW3
GSW3
GSW4
GSW4 With depth scale sign according to font size and reading distance standards
General
257
GWA General - Way Finding
GWA1
GWA1 All parks entrances shall display a visual and tactile map of the main facilities, displaying the North symbol at the top of the map with
oral information, if required
258 General
GWA General - Way Finding
GWA2
≤450mm
GWA3
≤800mm GWA4
1200mm
30˚ to 45˚
900mm
GWA3 Dimension of the tactile map ≤800 x 450mm and the font size >20mm San serif type
GWA4 The height of tactile map horizontal or inclined from the foor 900- 1200mm and the inclination between 300 to 450
General
259
GWA General - Way Finding
1000mm
GWA6
Max 1750mm
GWA5
Min 1250mm
260 General
GWA General - Way Finding
GWA7
GWA7 All public buildings have the name and Makani number on façade and directory inside the lobby
General
261
GWA General - Way Finding
30 Meters
GWA9
GWA13
GWA9 In buildings, orientation signs every 30 meters, including exit and toilets and other services
GWA13 Directional signs are simple, clearly visible, good shape and well organized with no duplicated information
and with refectance contrast ≥50 LRV
262 General
GWA General - Way Finding
70 Meters
GWA10
GWA10 In parks and open spaces orientation sign every 70 meters for nearest exit and nearest toilets
General
263
GWA General - Way Finding
70 Meters
GWA10
GWA10 In parks and open spaces orientation sign every 70 meters for nearest exit and nearest toilets
264 General
GWA General - Way Finding
GWA8
GWA12
GWA11
10-30mm
General
265
GWA General - Way Finding
≥3.7≤4.5mm ≥2.5≤2.6mm
≥2.5≤2.6mm
≥6.2≤7.1mm
≥10.0≤10.8mm
≥1.2≤1.9mm
≥6.0≤6.1mm
10-30mm
GWA14 ≤ 0.50mm GWA15
GWA14 Braille character located at the bottom left of the destination sign at distance of 10 - 30mm, according to ISO 7000 : 2004 standards
GWA15 Pictograms and symbols follow ISO 7000 : 2004 standards
266 General
GWA General - Way Finding
2mm
≥30mm
GWA16
2-5mm
GWA16
GWA16 Symbol height ≥ 30mm and thickness 2 - 5mm for letters and 2mm for symbols
General
267
GWA General - Way Finding
≤1600mm
≥1200mm
GWA17
GWA17 Signs at walls located at height 1200 - 1600mm on the left side of the door
268 General
GWA General - Way Finding
15˚ - 30˚
Min 1000mm
GWA18
2000mm
GWA19
1700mm
GWA19 Digital screens located at height 1700-2000mm, with slight inclination (150 - 300) and visible from a minimum distance of 1000mm
General
269
GWA General - Way Finding
20 Meters
min 140mm-(180mm) Recommended
≥ 50 Meters
GWA20
270 General
GWA General - Way Finding
GWA20
Reading distance Minimum Font Size Recommended Font Size
≥50 meters 170mm 200mm
General
271
GWA General - Way Finding
2200 mm
GWA21
Access
ible Path
GWA21 Signs out of the accessible path and clear headroom ≥ 2200 mm
272 General
@DubaiMunicipality
˜°° ° ° ° ° °˛˝˙ˆˇ˛˘ ˙°° ° ° ° ˜°° ° ° ° ° °˙˛ °° ° ° °
Developing a happy and sustainable city