NLE11MF.

2
Energy-optimized MBP Compressor
R134a
220-240V 50Hz
General
Code number 105G6197
Approvals EN 60335-2-34 w. Annex AA, CCC
Compressors on pallet 80

Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -25 to 10 –
Voltage range V 198 to 242/254 –
Max. condensing temperature continuous (short) °C 65 (70) –
Max. winding temperature continuous (short) °C 125 (135) –

Cooling requirements
Frequency Hz 50 60 S = Static cooling normally sufficient
O = Oil cooling
Application LBP MBP HBP LBP MBP HBP
F1 = Fan cooling 1.5 m/s
32°C F2 F2 – – – – (compressor compartment temperature
38°C F2 F2 – – – – equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
43°C F2 F2 – – – –
SG = Suction gas cooling normally sufficent
Remarks on application: – = not applicable in this area
Voltage range: without run capacitor: 198 to 242V / with run capacitor: 198 to 254V

Motor
Motor type CSIR/RSIR/RSCR
LRA (rated after 4 sec. UL984), HST | LST A 13.1 11.4
Cut in Current, HST | LST A 13.1 15.7
Resistance, main | start winding (25°C) Ω 8.8 19.0

Design
Displacement cm3 11.15
Oil quantity (type) cm3 300 (polyolester)
Maximum refrigerant charge g 600
3
Free gas volume in compressor cm 2360
Weight without electrical equipment kg 10.9

Dimensions
Height mm A 203
B 197
B1 –
B2 –
Suction connector location/I.D. mm | angle C 8.2 | 15°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 25°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 21°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:

October 2017 DES.D.410.K2.02 1/3


EN 12900 LBP 220V, 50Hz, fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 311 340 404 516 649 749 805 985 1192 1292 1428
Power cons. in W 224 234 254 286 320 342 354 387 418 431 447
Current cons. in A 1.72 1.76 1.83 1.92 2.00 2.04 2.07 2.15 2.24 2.28 2.35
COP in W/W 1.38 1.45 1.59 1.80 2.03 2.19 2.27 2.55 2.85 3.00 3.20

EN 12900 MBP 220V, 50Hz, fan cooling F2


Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 290 318 378 484 611 706 759 931 1129 1226 1356
Power cons. in W 231 241 261 295 331 355 368 405 441 457 476
Current cons. in A 1.78 1.82 1.89 1.97 2.05 2.11 2.14 2.23 2.35 2.41 2.49
COP in W/W 1.26 1.32 1.45 1.64 1.85 1.99 2.06 2.30 2.56 2.68 2.85

ASHRAE LBP 220V, 50Hz, fan cooling F2


Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 300 331 396 513 654 761 821 1018 1246 1357 1508
Power cons. in W 224 235 257 293 334 362 377 421 466 485 510
Current cons. in A 1.79 1.82 1.89 2.00 2.11 2.19 2.24 2.38 2.56 2.65 2.78
COP in W/W 1.34 1.41 1.54 1.75 1.96 2.10 2.18 2.42 2.68 2.80 2.96

ASHRAE MBP 220V, 50Hz, fan cooling F2


Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 268 295 353 457 582 678 731 905 1107 1205 1339
Power cons. in W 222 232 254 290 330 358 373 416 460 479 503
Current cons. in A 1.79 1.82 1.89 2.00 2.11 2.19 2.24 2.38 2.56 2.65 2.78
COP in W/W 1.21 1.27 1.39 1.57 1.76 1.89 1.96 2.17 2.41 2.51 2.66

Accessories for NLE11MF.2 Figure Code number Test conditions EN 12900 ASHRAE
LBP MBP LBP MBP
ePTC starting device 6.3 mm spade connectors – Condensing temperature 40°C 45°C 54.4°C 54.4°C
a1
4.8 mm spade connectors 103N0050 Ambient temperature 32°C 32°C 32.2°C 35°C
Starting relay 6.3 mm spade connectors a2 117U6003 Suction gas temperature 20°C 20°C 32.2°C 35°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature no subcooling 32.2°C 46.1°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919

2/3 DES.D.410.K2.02 October 2017


EN 12900 LBP 220V, 50Hz, RC 4 µF, ePTC consumption incl., fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 315 345 409 523 658 759 815 998 1208 1309 1447
Power cons. in W 211 220 239 269 301 322 333 364 393 406 420
Current cons. in A 1.62 1.66 1.72 1.80 1.88 1.92 1.94 2.02 2.10 2.15 2.21
COP in W/W 1.49 1.57 1.71 1.94 2.19 2.36 2.45 2.74 3.07 3.23 3.44

EN 12900 MBP 220V, 50Hz, RC 4 µF, ePTC consumption incl., fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 294 323 383 491 619 715 769 943 1144 1242 1374
Power cons. in W 217 227 246 277 311 334 346 381 415 430 448
Current cons. in A 1.68 1.71 1.77 1.86 1.93 1.98 2.01 2.10 2.21 2.26 2.34
COP in W/W 1.35 1.42 1.56 1.77 1.99 2.14 2.22 2.48 2.76 2.89 3.07

ASHRAE LBP 220V, 50Hz, RC 4 µF, ePTC consumption incl., fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 304 335 401 520 662 771 832 1031 1262 1375 1528
Power cons. in W 211 221 241 276 314 3404 354 396 438 456 479
Current cons. in A 1.68 1.72 1.78 1.88 1.99 2.06 2.10 2.24 2.41 2.50 2.62
COP in W/W 1.44 1.52 1.66 1.88 2.11 2.27 2.35 2.60 2.88 3.01 3.19

ASHRAE MBP 220V, 50Hz, RC 4 µF, ePTC consumption incl., fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 271 299 358 463 590 687 741 917 1121 1221 1356
Power cons. in W 209 219 239 273 311 337 350 391 433 451 473
Current cons. in A 1.68 1.72 1.78 1.88 1.99 2.06 2.10 2.24 2.41 2.50 2.62
COP in W/W 1.30 1.37 1.50 1.70 1.90 2.04 2.11 2.34 2.59 2.71 2.86

Accessories for NLE11MF.2 Figure Code number Test conditions EN 12900 ASHRAE
LBP MBP LBP MBP
ePTC starting device 6.3 mm spade connectors – Condensing temperature 40°C 45°C 54.4°C 54.4°C
a1
4.8 mm spade connectors 103N0050 Ambient temperature 32°C 32°C 32.2°C 35°C
Run capacitor 4 µF 4.8 mm spade connectors e 117-7119 Suction gas temperature 20°C 20°C 32.2°C 35°C
(optional) Liquid temperature no subcooling 32.2°C 46.1°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919

Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the
respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved. www.secop.com

3/3 DES.D.410.K2.02 October 2017