Tempest 702 Relnote 2013
Tempest 702 Relnote 2013
Copyright ©1994-2012 Roxar Software Solutions. All rights reserved. This user guide may not be copied,
photocopied, reproduced, translated, or converted to any electronic or machine-readable form in whole or
in part without prior written approval of Roxar.
While every effort has been made to ensure the accuracy of this user guide, Roxar accepts no responsibility
or liability for any errors or inaccuracies that it might contain. Be aware that continuous improvement of
the described products may lead to minor differences between the products and the user guide.
Roxar Software Solutions
Gamle Forusvei 17
P.O. Box 112, 4065 Stavanger, Norway
Contents
Chapter 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Tempest 7.0.1 Fixes and Tempest ENABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Enhancements Tempest MORE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Tempest VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Tempest PVTx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Tempest 7.0.2 Fixes and Tempest ENABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Enhancements Tempest MORE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Tempest VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Tempest PVTx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
© Roxar Software Solutions
Chapter
2
Software Support Support for all Tempest modules is provided by our 6 regional helpdesks,
demarcated in the map below. Each helpdesk is equipped to handle most
queries but also have access to specialist help and relevant programmers
when the need arises. Helpdesk information is updated at the following site:
www.roxarsoftwaresupport.com
© Roxar Software Solutions
Support personnel are also located in local offices - please consult our main
software support page for details:
www.roxarsoftwaresupport.com
Roxar Software Support is also available via the Roxar Software Portal, which allows you to
submit new support cases, review old cases, access our technical knowledge
Portal base, register for training courses and update your profile. It also enables
system administrators to download software versions.
Launching Your installation of Tempest will comprise one, or more, of the 5 modules:
Tempest • ENABLE
• MORE
• VIEW
• PVTx
• VENTURE
Depending on the configuration, you will have one or two desktop icons
from which to launch Tempest.
The Tempest VIEW icon will be present with all installations and should be
launched if you are to use VIEW, MORE, PVTx or VENTURE (or any
combination of these).
The Tempest ENABLE icon will be present only if your license includes
Tempest ENABLE. Tempest ENABLE should be launched if you wish to run
ENABLE. Tempest VIEW will be opened automatically as the user interface,
from which you will also be able to run MORE, PVTx and VENTURE.
© Roxar Software Solutions
Project All Tempest (.tprj) projects, are readable in version 7. On loading a pre
version 7 project into Tempest 7, customers should preserve the old project
Compatibility and save the new project as a new .tprj file.
Given the new functionality in version 7, backwards compatibility to 6.7 is
not guaranteed.
In most cases, ENABLE 2.4 xml projects can be loaded directly into Tempest
7. In some cases, intervention may be required. Please contact support if you
require assistance in project loading.
Your version 7 license will allow access to ENABLE versions 2.4 and 2.3.
Training
Tempest VIEW A set of video tutorials has been created for Tempest VIEW to allow you to
self train.
These are available in the Roxar Software Portal training section, and also
via the programme installation:
installation_folder/simulation/videos/v7.0/view
Tempest ENABLE A set of printed tutorials, along with project datasets, is available via the
programme installation:
installation_folder/tutorials/enable/v7.0
Tempest MORE A set of printed tutorials, along with project datasets, is available via the
programme installation:
installation_folder/tutorials/more/v7.0
Technical reference documents for MORE can also be found via the Tempest
Help Menu… ➥ MORE Tech Ref
Classroom Training Roxar runs 2 classroom based courses for Tempest products:
• Reservoir Simulation using Tempest (3 days)
• Managing Uncertainty before production starts and after History
Matching with ENABLE (3 days)
Please visit our website Training section to find scheduled courses, or email
[email protected] to make a training query.
Chapter
3
Introduction Tempest 7.0.1 is a maintenance release of Tempest 7 including the following
modules:
• ENABLE
• MORE
• VIEW
• PVTx
• VENTURE
In addition to numerous fixes, this version contains the following changes
and enhancements for the listed modules compared with version 7.0.0.
Tempest MORE • Component level tracers and ability to set tracers above and below the
fluid contacts
© Roxar Software Solutions
Tempest PVTx • Viscosibility can be optionally exported in the MORE OPVT table
• Improvements in viscosity calculations at low and high pressures
Training • New videos are included, showing how to use the Calculators and set up
3D cross sections
• A Help page for new users is available
Chapter
4
Introduction Tempest 7.0.2 is a maintenance release of Tempest 7 including the following
modules:
• ENABLE
• MORE
• VIEW
• PVTx
• VENTURE
It is recommended that all clients upgrade to this Tempest 7.0.2 version.
In addition to numerous fixes, this version contains the following changes
and enhancements for the listed modules compared with version 7.0.1.
Tempest ENABLE • Improvements in robustness when creating a new dataset from scratch
with no ENABLE header
• Reduced memory usage for large numbers of runs with large include
files
• Greatly improved summary calculator performance
• Matching on RFT data when data not monotonic in depth is now
possible
• Improved performance when making multiple rapid changes
• Non-linear scaling applied to quality slider - increases sensitivity in
region of interest
• Quality filter on graph can filter on quality of displayed vector
© Roxar Software Solutions
Tempest MORE • WFSP option added to WFRA to suppress path sharing of remote
completions in fractured wells
• GPRI algorithm allows for BHP controlled swing producers
• Branch and segment totals are available to operations, also water gas
ratios for well/group/field
• BRANch events can have OPEN or SHUT arguments
• MAXCPU and MAXELAP options can be specified to the mored.bat
command
• Improvements to documentation