EC25A RF Test Report 22 4446451
EC25A RF Test Report 22 4446451
(PART 22)
Address: 13F. No.736, Zhongzheng Rd., Zhonghe Dist., New Taipei City 235, Taiwan
Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
( R.O.C)
Test Location (1): No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
33383, TAIWAN (R.O.C.)
Test Location (2): B2F., No.215, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231,
Taiwan, R.O.C
FCC Registration / 788550 / TW0003
Designation Number: 427177 / TW0011
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies
Brand: Quectel
The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2:
Expanded Uncertainty
Measurement Frequency
(k=2) (±)
9 kHz ~ 30 MHz 3.0400 dB
Radiated Emissions up to 1 GHz 30 MHz ~ 200 MHz 2.0153 dB
200 MHz ~ 1000 MHz 2.0224 dB
1 GHz ~ 18 GHz 1.0121 dB
Radiated Emissions above 1 GHz
18 GHz ~ 40 GHz 1.1508 dB
Note: 1. The calibration interval of the above test instruments is 12 / 24 months and the calibrations are
traceable to NML/ROC and NIST/USA.
2. The test was performed in HsinTien Chamber 1.
Test table
Radio
Communication
Analyzer
The EUT has been tested as an independent unit together with other necessary accessories or support units.
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
available modulations, data rates, antenna degree 90o and 180o, and antenna ports.
The worst case was found when positioned as the table below. Following channel(s) was (were) selected for
the final test as listed below:
WCDMA
EUT
Configure Test Item Available Channel Tested Channel Mode
Mode
- ERP 4132 to 4233 4132, 4182, 4233 WCDMA
- Radiated Emission 4132 to 4233 4132, 4182, 4233 WCDMA
Test Condition:
Test Item Environmental Conditions Input Power Tested By
ERP 25 deg. C, 65 % RH 3.8 Vdc Charles Hsiao
Radiated Emission 25 deg. C, 65 % RH 120 Vac, 60 Hz Charles Hsiao
The EUT makes a call to the communication simulator. The communication simulator station system controlled
a EUT to export maximum output power under transmission mode and specific channel frequency.
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:
Note: All test items have been performed and recorded as per the above standards.
Ant. Tower
1-4m
Variable
3 m
10m
EUT&
Support Units
Turn Table
80cm
Ground Plane
Test Receiver
Turn Table
Absorber
150 cm
Ground Plane
Test Receiver
For the actual test configuration, please refer to the attached file (Test Setup Photo).
Communication
Simulator EUT
The power of any emission outside of the authorized operating frequency ranges must be attenuated below
the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. The emission limit is equal to -13 dBm.
a. Substitution method is used for E.I.R.P measurement. In the semi-anechoic chamber, EUT placed on the
0.8 m (below or equal 1 GHz) and/or 1.5 m (above 1 GHz) height of Turn Table, rotated the table around
360 degrees to search the maximum radiation power and receiver antenna shall be rotated vertical and
horizontal polarization and moved height from 1 m to 4 m to find the maximum polar radiated power. The
“Read Value” is the spectrum reading the maximum power value.
b. The substitution horn antenna is substituted for EUT at the same position and signals generator export the
CW signal to the substitution antenna via a TX cable. Rotated the Turn Table and moved receiving antenna
to find the maximum radiation power. Adjust output power level of S.G to get a Value of spectrum reading
equal to “Read Value” of step a. Record the power level of S.G
c. EIRP = Output power level of S.G – TX cable loss + Antenna gain of substitution horn.
d. E.R.P power can be calculated form E.I.R.P power by subtracting the gain of dipole, E.R.P power = E.I.R.P
power - 2.15 dB.
NOTE: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 1 MHz/3 MHz.
No deviation.
Ant. Tower
1-4m
Variable
310m
m
EUT&
Support Units
Turn Table
80cm
Ground Plane
Test Receiver
Turn Table
Absorber
150 cm
Ground Plane
Test Receiver
For the actual test configuration, please refer to the attached file (Test Setup Photo).
WCDMA:
Low Channel
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.
If you have any comments, please feel free to contact us at the following:
Email: [email protected]
Web Site: www.bureauveritas-adt.com
The address and road map of all our labs can be found in our web site also.