‫ﺍﻟﻔﺻﻝ ﺍﻷﻭﻝ‬

‫ﺗﻌﺭﻳﻔﺎﺕ‬

‫ﺍﻟﺗﻌﺭﻳﻔﺎﺕ‬
‫ﺇﻣﺎﺭﺓ ﺃﻡ ﺍﻟﻘﻳﻭﻳﻥ‪.‬‬ ‫ﺍﻹﻣﺎﺭﺓ‬

‫ﺑﻠﺩﻳﺔ ﺃﻡ ﺍﻟﻘﻳﻭﻳﻥ‪.‬‬ ‫ﺍﻟﺑﻠﺩﻳﺔ‬

‫ﺍﻟﺟﻬﺎﺯ ﺍﻹﺩﺍﺭﻱ ﻭﺍﻟﻔﻧﻲ ﺑﺑﻠﺩﻳﺔ ﺃﻡ ﺍﻟﻘﻳﻭﻳﻥ‪.‬‬ ‫ﺳﻠﻁﺎﺕ ﺍﻟﺑﻠﺩﻳﺔ‬

‫ﺍﻟﺟﻬﺎﺯ ﺍﻟﻔﻧﻲ ﺍﻟﻣﺧﺗﺹ ﺑﺗﺭﺍﺧﻳﺹ ﺍﻟﺑﻧﺎء‬ ‫ﺍﻟﺳﻠﻁﺎﺕ ﺍﻟﻔﻧﻳﺔ‬


‫ﻭﻳﺷﻣﻝ ﺭﺅﻭﺳﺎء ﺍﻷﻗﺳﺎﻡ ﻭﺍﻟﻣﻬﻧﺩﺳﻳﻥ‬
‫ﻭﺍﻟﻣﺭﺍﻗﺑﻳﻥ ﻭﻣﻔﺗﺷﻲ ﺍﻟﻣﺑﺎﻧﻲ ﻭﺃﻱ ﺷﺧﺹ‬
‫ﻳﻧﺗﺩﺑﻪ ﻣﺩﻳﺭ ﺍﻟﺑﻠﺩﻳﺔ‪.‬‬

‫ﺍﻟﺷﺧﺹ ﺃﻭ ﺍﻷﺷﺧﺎﺹ ﺍﻟﺫﻳﻥ ﺻﺩﺭ ﺕ‬ ‫ﺍﻟﻣﺎﻟﻙ‬


‫ﺍﻟﻣﺧﻁﻁ ﺑﺄﺳﻣﺎﺋﻬﻡ‪.‬‬

‫ﺍﻟﺷﺧﺹ ﺍﻟﻣﺣﺩﺩ ﻣﻥ ﻗﺑﻝ ﺍﻟﻣﺎﻟﻙ ﻭﻳﺷﻣﻝ ﺫﻟﻙ‬ ‫ﻭﻛﻳﻝ ﺍﻟﻣﺎﻟﻙ‬


‫ﺍﻹﺳﺗﺷﺎﺭﻱ ﺃﻭ ﻣﻘﺎﻭﻝ ﺍﻟﻣﺎﻟﻙ‪.‬‬

‫ﻛﻝ ﺷﺧﺹ ﺃﻭ ﺃﻛﺛﺭ ﻳﻘﻭﻡ ﺑﻌﻣﻝ ﻣﻥ ﺃﻋﻣﺎﻝ‬ ‫ﺍﻟﻣﻧﻔﺫ‬


‫ﺍﻹﻋﻣﺎﺭ ﻭﻳﺷﻣﻝ ﺫﻟﻙ ﺍﻟﻣﻘﺎﻭﻟﻳﻥ ﻭﺍﻟﻔﻧﻳﻥ‬
‫ﻭﺍﻟﺣﺭﻓﻳﻥ ﻭﺍﻟﻌﻣﺎﻝ‪.‬‬
‫ﻫﻭ ﺍﻟﺗﺻﺭﻳﺢ ﺍﻟﺻﺎﺩﺭ ﻣﻥ ﺍﻟﺑﻠﺩﻳﺔ ﻭﺩﺍﺋﺭﺓ‬ ‫ﺍﻟﺗﺭﺧﻳﺹ ﺍﻹﺑﺗﺩﺍﺋﻲ‬
‫ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ ﻭﺍﻟﺫﻱ ﻳﺟﻳﺯ ﻟﻺﺳﺗﺷﺎﺭﻱ‬
‫ﺍﺳﺗﻛﻣﺎﻝ ﺑﺎﻗﻲ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺗﻣﻬﻳﺩﺍ ﻟﻠﻣﻭﺍﻓﻘﺔ‬
‫ﺍﻟﻧﻬﺎﺋﻳﺔ ﻋﻠﻳﻬﺎ‪.‬‬
‫ﺍﻟﺗﺻﺭﻳﺢ ﺑﺈﺟﺎﺯﺓ ﺍﻟﺑﺩء ﺑﺄﻋﻣﺎﻝ ﺍﻟﺑﻧﺎء‬ ‫ﺍﻟﺗﺭﺧﻳﺹ ﺍﻟﻧﻬﺎﺋﻲ‬
‫ﺍﻟﻣﺯﻣﻊ ﺗﻧﻔﻳﺫﻫﺎ ﻭﻓﻘﺎ ﻟﻠﻣﺧﻁﻁﺎﺕ‬
‫ﻭﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻣﻌﺗﻣﺩﺓ‪.‬‬

‫ﺩﻭﺍﺋﺭ ﺍﻟﺧﺩﻣﺎﺕ ﺍﻟﻣﺧﺗﺻﺔ ﺑﺈﻣﺎﺭﺓ ﺃﻡ ﺍﻟﻘﻳﻭﻳﻥ‬ ‫ﺩﻭﺍﺋﺭ ﺍﻟﺧﺩﻣﺎﺕ‬


‫ﺳﻭﺍء ﻛﺎﻧﺕ ﻣﺣﻠﻳﺔ ﺍﻭ ﺇﺗﺣﺎﺩﻳﺔ ﻭﺗﺷﻣﻝ ﺩﻭﺍﺋﺭ‬
‫ﺍﻟﻛﻬﺭﺑﺎء ﻭﺍﻟﻣﺎء ﻭﺍﻻﺗﺻﺎﻻﺕ ﻭﺍﻟﺩﻓﺎﻉ ﺍﻟﻣﺩﻧﻲ‬
‫‪.‬‬

‫ﺍﻟﺧﻁ ﺍﻟﻔﺎﺻﻝ ﺑﻳﻥ ﻗﻁﻌﺔ ﺃﺭﺽ ﻣﻌﻳﻧﺔ‬ ‫ﺣﺩﻭﺩ ﻗﻁﻌﺔ ﺍﻷﺭﺽ‬


‫ﻭﺍﻷﻣﻼﻙ ﺍﻷﺧﺭﻯ ﺍﻟﻣﺟﺎﻭﺭﺓ ﻟﻬﺎ ﺃﻭ ﺍﻟﺷﻭﺍﺭﻉ‬
‫ﻭﻣﺎﻓﻲ ﺣﻛﻣﻬﺎ‪.‬‬

‫ﺍﻟﺣﻳﺯ ﺃﻭ ﺍﻟﻔﺭﺍﻍ ﺍﻟﻣﻣﻠﻭﻙ ﻟﻺﻣﺎﺭﺓ ﺃﻭ ﺍﻟﺩﻭﻟﺔ‬ ‫ﺍﻟﻁﺭﻳﻖ ﺍﻟﻌﺎﻡ‬


‫ﻭﺍﻟﻣﺧﺻﺹ ﻟﻠﻣﺭﻭﺭ ﺍﻟﻌﺎﻡ ﻭﻳﺷﻣﻝ ﺫﻟﻙ‬
‫ﺍﻟﻁﺭﻕ ﺍﻟﺭﺋﻳﺳﺔ ﻭﺍﻟﺷﻭﺍﺭﻉ ﻭﺍﻟﻣﻣﺭﺍﺕ‪.‬‬
‫ﺍﻟﺷﺎﺭﻉ ﺍﻟﻣﻣﻠﻭﻙ ﻟﻸﻓﺭﺍﺩ ﻭﺍﻟﺫﻱ ﻳﻣﻬﺩﻩ‬ ‫ﺍﻟﻁﺭﻳﻖ ﺍﻟﺧﺎﺹ‬
‫ﺷﺧﺹ ﺃﻭ ﺃﻛﺛﺭ ﻟﻠﻭﺻﻭﻝ ﺇﻟﻰ ﺃﻣﻼﻛﻬﻡ‪.‬‬

‫ﻛﻝ ﺇﻧﺳﺎﻥ ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﺭﺳﻲ ﺍﻟﻣﺗﺣﺭﻙ ﺃﻭ‬ ‫ﺫﻭﻯ ﺍﻹﺣﺗﻳﺎﺟﺎﺕ ﺍﻟﺧﺎﺻﺔ‬


‫ﺍﻟﻌﻛﺎﺯﺍﺕ ﺃﻭ ﺍﻟﻭﺳﺎﺋﻝ ﺍﻟﻣﺗﺣﺭﻛﺔ ﻟﻠﻣﺳﺎﻋﺩﺓ‬
‫ﻓﻲ ‪ .......‬ﺑﻣﺎ ﻓﻲ ﺫﻟﻙ ﺍﻟﻣﺷﻠﻭﻝ ﻭﺍﻟﻣﻘﻌﺩ‬
‫ﻭﻓﺎﻗﺩ ﺍﻷﻁﺭﺍﻑ ﻭﺍﻟﻛﻔﻳﻑ ﻭﺍﻷﺻﻡ ﻭﺍﻟﻣﺭﺿﻰ‬
‫ﻭﻛﺑﺎﺭ ﺍﻟﺳﻥ ﻏﻳﺭ ﺍﻟﻘﺎﺩﺭﻳﻥ ﻋﻠﻰ ﺍﻟﺣﺭﻛﺔ‪.‬‬

‫ﺟﺯء ﻣﻥ ﺍﻟﻁﺭﻳﻖ ﺍﻟﻌﺎﻡ ﻳﺧﺻﺹ ﻟﻣﺭﻭﺭ‬ ‫ﺍﻟﺭﺻﻳﻑ‬


‫ﺍﻟﻣﺷﺎﺓ‪.‬‬
‫ﺍﻟﺧﻁ ﺍﻟﻣﻌﺗﻣﺩ ﺍﻟﺫﻱ ﻳﺣﺩﺩ ﺍﻟﻁﺭﻳﻖ ﻭﻳﻔﺻﻝ‬ ‫ﺧﻁ ﺍﻟﺗﻧﻅﻳﻡ‬
‫ﺑﻳﻥ ﺍﻷﻣﻼﻙ ﺍﻟﺧﺎﺻﺔ ﻭﺍﻟﻣﻧﻔﻌﺔ ﺍﻟﻌﺎﻣﺔ‪.‬‬

‫ﻣﺳﺎﺭ ﺍﻟﺧﻁ ﺍﻟﺫﻱ ﻳﺣﺩﺩ ﻣﻧﺗﺻﻑ ﻋﺭﺽ‬ ‫ﻣﺣﻭﺭﺍﻟﻁﺭﻳﻖ‬


‫ﺍﻟﻁﺭﻳﻖ‪.‬‬

‫ﺍﻟﻣﺳﺎﻓﺔ ﺑﻳﻥ ﺧﻁﻲ ﺍﻟﺗﻧﻅﻳﻡ ﻋﻠﻰ ﺟﺎﻧﺑﻲ‬ ‫ﻋﺭﺽ ﺍﻟﻁﺭﻳﻖ‬


‫ﺍﻟﻁﺭﻳﻖ‪.‬‬

‫ﺍﻟﺧﻁ ﺍﻟﺫﻱ ﻳﺳﻣﺢ ﺑﺎﻟﺑﻧﺎء ﻋﻠﻳﻪ ﺳﻭﺍء ﻛﺎﻥ‬ ‫ﺧﻁ ﺍﻟﺑﻧﺎء‬


‫ﻣﻁﺎﺑﻘﺎ ﻟﺣﺩ ﺍﻟﻁﺭﻳﻖ ﺃﻭ ﺍﻟﺗﻧﻅﻳﻡ ﺃﻭ ﺭﺍﺩﺍ ﻋﻠﻰ‬
‫ﺃﻱ ﻣﻧﻬﺎ ﺑﻣﺳﺎﻓﺔ ﺗﺣﺩﺩﻫﺎ ﻗﺭﺍﺭﺍﺕ ﺗﺻﺩﺭ ﻋﻥ‬
‫ﺩﺍﺋﺭﺓ ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ‪.‬‬

‫ﻁﺎﺑﻖ ﻳﻘﻊ ﺗﺣﺕ ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﻭﻳﻛﻭﻥ‬ ‫ﻁﺎﺑﻖ ﺍﻟﺗﺳﻭﻳﺔ‬


‫ﺍﻻﻧﺣﺩﺍﺭ ﺍﻟﻁﺑﻳﻌﻲ ﺩﺍﺧﻝ ﺣﺩﻭﺩ ﺍﻟﺑﻧﺎء ﺳﺑﺑﺎ ﻓﻲ‬
‫ﻭﺟﻭﺩﻩ ﻭﺗﻅﻬﺭ ﻭﺍﺟﻬﺗﻪ ﻛﺎﻣﻠﺔ ﻓﻭﻕ ﻣﻧﺳﻭﺏ‬
‫ﺍﻷﺭﺽ ﺍﻟﻁﺑﻳﻌﻳﺔ ﻣﻥ ﺍﻟﻧﺎﺣﻳﺔ ﺍﻷﻛﺛﺭ‬
‫ﺇﻧﺧﻔﺎﺿﺎ ﻓﻲ ﺍﻟﻣﻧﺳﻭﺏ‪.‬‬

‫ﺍﻟﻁﺎﺑﻖ ﺍﻟﺫﻱ ﻳﻘﻊ ﺗﺣﺕ ﻣﻧﺳﻭﺏ ﺍﻻﺭﺽ‬ ‫ﺍﻟﻁﺎﺑﻖ ﺍﻟﺳﻔﻠﻲ‬


‫ﺍﻟﻁﺑﻳﻌﻳﺔ‪.‬‬
‫(‬‫)ﺍﻟﺳﺭﺩﺍﺏ‬

‫ﺍﻟﻁﺎﺑﻖ ﺍﻟﺛﺎﻧﻭﻱ ﺍﻟﺫﻱ ﻳﻛﻭﻥ ﺑﻳﻥ ﺍﻟﻁﺎﺑﻖ‬ ‫ﺍﻟﻁﺎﺑﻖ ﺍﻟﺩﺍﺧﻠﻲ‬


‫ﺍﻷﺭﺿﻲ ﻭﺍﻷﻭﻝ ﻳﻛﻭﻥ ﺍﺳﺗﻌﻣﺎﻟﻪ ﻣﻛﻣﻼ‬
‫ﻭﺗﺎﺑﻌﺎ ﻟﻠﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﻭﻣﺗﺻﻼً ﺍﺗﺻﺎﻻ ً‬
‫ﻣﺑﺎﺷﺭﺍ‪.‬‬
‫ً‬
‫ﻭﺣﺩﺓ ﺳﻛﻧﻳﺔ ﻓﻭﻕ ﺍﻟﻁﺎﺑﻖ ﺍﻷﺧﻳﺭ ﻣﻥ ﺍﻟﻣﺑﻧﻰ‬ ‫ﻁﺎﺑﻖ ﺍﻟﺳﻁﺢ‬
‫ﺍﻟﻣﺗﻌﺩﺩ ﺍﻟﻁﻭﺍﺑﻖ‬

‫ﻫﻭ ﺍﻟﻁﺎﺑﻖ ﺍﻟﺫﻱ ﻳﺧﺻﺹ ﺑﺎﻟﻛﺎﻣﻝ‬ ‫ﻁﺎﺑﻖ ﺍﻟﺧﺩﻣﺎﺕ ﺍﻟﻣﻳﻛﺎﻧﻳﻛﻳﺔ‬


‫ﻟﻭﺿﻊ ﺍﻷﺟﻬﺯﺓ ﻭﺍﻟﻣﻌﺩﺍﺕ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ‬
‫ﻭﺍﻟﺧﺎﺹ ﺑﺎﻟﻣﺑﻧﻰ ﻭﻻ ﻳﺳﻣﺢ ﺑﺎﺳﺗﺧﺩﺍﻣﻪ ﻷﻱ‬
‫ﺃﻏﺭﺍﺽ ﺃﺧﺭﻯ‪.‬‬

‫ﺍﻟﻣﺳﺎﺣﺔ ﺍﻟﻣﻣﺗﺩﺓ ﺧﺎﺭﺝ ﺧﻁ ﻭﺍﺟﻬﺔ ﺍﻟﻣﺑﻧﻰ‬ ‫ﺍﻟﺷﺭﻓﺔ ﺍﻟﺑﺎﺭﺯﺓ) ﺍﻟﺑﻠﻛﻭﻧﺔ‬


‫(‬

‫ﻭﺗﻛﻭﻥ ﻣﺳﻘﻭﻓﺔ ﺃﻭ ﻣﻛﺷﻭﻓﺔ‪.‬‬

‫ﺍﻟﻐﺭﻓﺔ ﺍﻟﺗﻲ ﺗﻛﻭﻥ ﺟﺯءﺍ ﻣﻧﻬﺎ ﻣﻐﻠﻘﺎ ﻭﻣﻣﺗﺩﺍ‬ ‫ﺍﻟﻐﺭﻓﺔ ﺍﻟﺑﺎﺭﺯﺓ‬


‫ﺧﺎﺭﺝ ﺧﻁ ﻭﺍﺟﻬﺔ ﺍﻟﻣﺑﻧﻰ‪.‬‬

‫ﺟﺯء ﻣﻥ ﺍﻟﺑﻧﺎء ﻏﻳﺭ ﻣﺄﻫﻭﻝ ﻳﺷﻣﻝ ﺫﻟﻙ‬ ‫ﺍﻟﺑﺭﻭﺯ ﺍﻟﺯﺧﺭﻓﻲ ﺍﻟﻣﻌﻣﺎﺭﻱ‬


‫ﺍﻟﻧﺗﻭﺍءﺍﺕ ﻭﺍﻹﻁﺎﺭﺍﺕ ﺍﻟﺟﻣﺎﻟﻳﺔ ﻭﺃﺣﻭﺍﺽ‬
‫ﺍﻟﺯﻫﻭﺭ ﺍﻟﻣﻌﻠﻘﺔ ﻭﺇﻟﻰ ﺫﻟﻙ‪.‬‬

‫ﻣﺳﺎﺣﺔ ﻣﻔﺗﻭﺣﺔ ﻣﻥ ﺃﻋﻠﻰ ﻋﻠﻰ ﺍﻟﻔﺿﺎء‬ ‫ﺍﻟﻣﻧﻭﺭ‬


‫ﺍﻟﺳﻣﺎﻭﻱ ﺩﺍﺧﻝ ﺍﻟﺑﻧﺎء ﺍﻟﻣﻁﻝ ﻋﻠﻳﻬﺎ ﻭﻻ‬
‫ﻳﺟﻭﺯ ﺗﻐﻁﻳﺔ ﺃﻱ ﺟﺯء ﻣﻧﻬﺎ‪.‬‬

‫(‬ ‫ﻣﻅﻠﺔ ﺍﻟﺗﻌﺭﻳﺵ)ﺑﺭﺟﻭﻻ‬


‫ﻛﻝ ﺳﻁﺢ ﺫﻱ ﻓﺭﺍﻏﺎﺕ ﺷﺭﻳﻁﺔ ﺃﻻ ﺗﻘﻝ‬
‫ﻣﺳﺎﺣﺔ )ﺑﺭﺟﻭﻻ (‬
‫ﻫﺫﻩ ﺍﻟﻔﺭﺍﻏﺎﺕ ﻋﻥ ‪ 50%‬ﻣﻥ ﻣﺳﺎﺣﺔ‬
‫ﺍﻟﻣﻅﻠﺔ‪.‬‬

‫ﺍﻟﻣﺳﺎﻓﺔ ﺍﻟﺭﺃﺳﻳﺔ ﻣﺣﺳﻭﺑﺔ ﻣﻥ ﻣﻧﺳﻭﺏ‬ ‫ﺍﺭﺗﻔﺎﻉ ﺍﻟﺑﻧﺎء‬


‫ﺭﺻﻳﻑ ﺍﻟﻁﺭﻳﻖ ﺍﻟﻌﺎﻡ ﺍﻟﻣﻘﺎﺑﻝ ﻟﻭﺍﺟﻬﺔ ﺍﻟﺑﻧﺎء‬
‫ﺇﻟﻰ ﺃﻋﻠﻰ ﻧﻘﻁﺔ ﻣﻥ ﻣﻧﺳﻭﺏ ﺳﻁﺢ ﺁﺧﺭ‬
‫ﻁﺎﺑﻖ ﻋﻠﻭﻱ ﻭﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﻭﻗﻭﻉ ﺍﻟﺑﻧﺎء‬
‫ﻋﻠﻰ ﻁﺭﻳﻖ ﻋﺎﻡ ﻳﺣﺳﺏ ﺍﻻﺭﺗﻔﺎﻉ ﻣﻥ‬
‫ﻣﻧﺳﻭﺏ ﺍﻟﺻﻔﺭ ﺍﻟﻣﺳﺎﺣﻲ ﻟﻠﻣﻧﻁﻘﺔ ﻭﺍﻟﻣﺣﺩﺩ‬
‫ﻣﻥ ﻗﺑﻝ ﺩﺍﺋﺭﺓ ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ‪.‬‬

‫ﺍﻟﻣﺳﺎﻓﺔ ﺍﻟﺭﺃﺳﻳﺔ ﻣﺣﺳﻭﺑﺔ ﻣﻥ ﻣﻧﺳﻭﺏ‬ ‫ﺍﺭﺗﻔﺎﻉ ﺍﻟﻁﺎﺑﻖ‬


‫ﺍﻟﺗﺷﻁﻳﺑﺎﺕ ﺍﻟﻧﻬﺎﺋﻳﺔ ﻷﺭﺿﻳﺔ ﺍﻟﻁﺎﺑﻖ ﺇﻟﻰ‬
‫ﻣﻧﺳﻭﺏ ﺑﺎﻁﻥ ﺍﻟﺳﻘﻑ‪.‬‬

‫ﺍﻟﻧﺳﺑﺔ ﺍﻟﻣﺋﻭﻳﺔ ﻟﻣﺳﺎﺣﺔ ﺍﻟﺟﺯء ﺍﻟﻣﺳﻘﻭﻑ‬ ‫ﻧﺳﺑﺔ ﺍﻟﺑﻧﺎء‬


‫ﻣﻧﺳﻭﺑﺎ ﻹﺟﻣﺎﻟﻲ ﻣﺳﺎﺣﺔ ﻗﻁﻌﺔ ﺍﻷﺭﺽ‬
‫ﺍﻟﻛﻠﻳﺔ ﺍﻟﺗﻲ ﻳﻘﻊ ﻋﻠﻳﻬﺎ ﺍﻟﺑﻧﺎء ‪ ،‬ﻭﻻ ﻳﺩﺧﻝ‬
‫ﻓﻲ ﺗﻠﻙ ﺍﻟﻧﺳﺑﺔ ﺍﻟﺑﺭﻭﺯ ﺍﻟﺯﺧﺭﻓﻲ ﺍﻟﻣﻌﻣﺎﺭﻱ‬
‫ﻭﻣﻅﻠﺔ ﺍﻟﺳﻳﺎﺭﺍﺕ‪.‬‬
‫ﺍﻟﻧﺳﺑﺔ ﻣﺎﺑﻳﻥ ﺟﻣﻠﺔ ﻣﺳﻁﺣﺎﺕ ﺟﻣﻳﻊ ﺍﻟﻁﻭﺍﺑﻖ‬ ‫ﺍﻟﻧﺳﺑﺔ ﺍﻟﻁﺎﺑﻘﻳﺔ‬
‫ﺑﺎﻟﻣﺑﻧﻰ ﻭﻣﺳﺎﺣﺔ ﻗﻁﻌﺔ ﺍﻷﺭﺽ ﺍﻟﻣﻘﺎﻡ‬
‫ﻋﻠﻳﻬﺎ‬
‫ﻓﻧﺎء ﺃﻭ ﻓﺭﺍﻍ ﻳﺗﺭﻙ ﺑﻳﻥ ﺧﻁ ﺍﻟﺑﻧﺎء ﻭﺣﺩﻭﺩ‬ ‫ﺍﻹﺭﺗﺩﺍﺩ‬
‫ﻗﻁﻌﺔ ﺍﻷﺭﺽ ﻭﻻ ﻳﺳﻣﺢ ﺑﺎﻟﺑﻧﺎء ﻓﻳﻪ‪.‬‬
‫ﺣﺎﺟﺯ ﻭﺍﻗﻲ ﻳﺷﻳﺩ ﻋﻠﻰ ﺍﻟﻣﺣﻳﻁ ﺍﻟﺧﺎﺭﺟﻲ‬ ‫ﺣﺎﺟﺯ ﺍﻟﺳﻁﺢ‬
‫ﻟﺳﻁﺢ ﺁﺧﺭ ﻁﺎﺑﻖ ﻋﻠﻭﻯ ﻟﻠﺑﻧﺎء ﻣﻥ ﺃﺟﻝ‬
‫ﺍﻟﺳﻼﻣﺔ ﺍﻟﻌﺎﻣﺔ‪.‬‬

‫ﻫﻭ ﺍﻟﺳﻠﻡ ﺍﻷﺳﺎﺳﻲ ﻟﻠﺑﻧﺎء ﻭﻳﺳﺗﺧﺩﻡ ﻓﻲ‬ ‫ﺍﻟﺳﻠﻡ ﺍﻟﺭﺋﻳﺳﻲ‬


‫ﺍﻟﻭﺻﻭﻝ ﺇﻟﻰ ﺟﻣﻳﻊ ﻁﻭﺍﺑﻖ ﺍﻟﺑﻧﺎء‪.‬‬

‫ﺍﻟﺳﻠﻡ ﺍﻹﺿﺎﻓﻲ ﻟﺑﻧﺎء ﻓﻳﻪ ﺍﻟﺳﻠﻡ ﺍﻟﺭﺋﻳﺳﻲ‬ ‫ﺍﻟﺳﻠﻡ ﺍﻟﺛﺎﻧﻭﻱ‬


‫ﻭﻳﺳﺗﺧﺩﻡ ﻓﻲ ﺍﻟﻭﺻﻭﻝ ﺇﻟﻰ ﺟﻣﻳﻊ ﻁﻭﺍﺑﻖ‬
‫ﺍﻟﺑﻧﺎء‪.‬‬

‫ﺍﻟﺑﻧﺎء ﺍﻟﻣﺷﻳﺩ ﻣﻥ ﺍﻟﻁﺎﺑﻭﻕ ﺃﻭ ﺍﻷﺳﻣﻧﺕ‬ ‫ﺍﻟﺑﻧﺎء ﺍﻟﺛﺎﺑﺙ‬


‫ﺍﻟﻣﺳﻠﺢ ﺃﻭ ﺃﻳﺔ ﻣﻭﺍﺩ ﺁﺧﺭﻯ‪.‬‬

‫ﺍﻟﺑﻧﺎء ﺍﻟﻣﺷﻳﺩ ﻣﻥ ﺃﻳﺔ ﻣﻭﺍﺩ ﺑﻧﺎء ﺑﺳﻳﻁﺔ ﻭﻳﺗﻡ‬ ‫ﺍﻟﺑﻧﺎء ﺍﻟﻣﺅﻗﺕ‬


‫ﺗﺭﺧﻳﺻﻪ ﻟﻔﺗﺭﺓ ﻣﺣﺩﺩﺓ ﻓﻘﻁ‪.‬‬

‫ﻭﺣﺩﺓ ﺳﻛﻧﻳﺔ ﻣﺳﺗﻘﻠﺔ ﻣﻛﻭﻧﺔ ﻣﻥ ﻁﺎﺑﻖ‬ ‫ﺍﻟﻣﻧﺯﻝ‬


‫ﺃﻭ ﺃﻛﺛﺭ ﻭﻣﺗﺻﻠﺔ ﺑﺳﻠﻡ ﺩﺍﺧﻠﻲ‪.‬‬

‫ﻣﻥ ﺍﻟﺑﻧﺎء ﻳﺅﻟﻑ ﻓﻲ ﻣﺟﻣﻭﻋﺔ ﻣﺳﻛﻧﺎ‬ ‫ﺍﻟﺷﻘﺔ‬


‫ﻣﺳﺗﻘﻼ ﻭﺍﺣﺩًﺍ‪.‬‬

‫ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺗﻲ ﻳﺳﻣﺢ ﻓﻳﻬﺎ ﺑﺎﻻﺳﺗﻌﻣﺎﻝ‬ ‫ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺗﺟﺎﺭﻳﺔ‬


‫ﺍﻟﺗﺟﺎﺭﻱ ﻭﻓﻘﺎ ﻟﻧﻅﺎﻡ ﺗﺻﻧﻳﻑ ﻭﺗﻘﻳﻳﻥ‬
‫ﺍﺳﺗﻌﻣﺎﻻﺕ ﺍﻷﺭﺍﺿﻲ ﻓﻲ ﺍﻹﻣﺎﺭﺓ‪.‬‬
‫ﻣﺟﻣﻭﻋﺔ ﺍﻟﻣﺣﻼﺕ ﺃﻭ ﺍﻟﻣﻌﺎﺭﺽ ﺗﻔﺗﺢ ﻋﻠﻰ‬ ‫ﻣﺭﻛﺯ ﺗﺟﺎﺭﻱ‬
‫ﺳﺎﺣﺎﺕ ﺃﻭ ﻣﻣﺭﺍﺕ ﺩﺍﺧﻠﻳﺔ ﻭﻣﻛﻳﻔﺔ‪.‬‬
‫ﺧﻁﻭﻁ ﺍﻷﻧﺎﺑﻳﺏ ﻭﺍﻹﻧﺷﺎءﺍﺕ ﺍﻟﻣﻘﺎﻣﺔ ﻟﻧﻘﻝ‬ ‫ﺷﺑﻛﺔ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ‬
‫ﻭﻣﻌﺎﻟﺟﺔ ﻭﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ‬
‫ﺧﺎﺭﺝ ﺣﺩﻭﺩ ﻗﻁﻌﺔ ﺍﻷﺭﺽ‪.‬‬
‫ﺧﻁﻭﻁ ﺍﻷﻧﺎﺑﻳﺏ ﻭﺍﻹﻧﺷﺎءﺍﺕ ﺍﻟﻣﻘﺎﻣﺔ ﻟﻧﻘﻝ‬ ‫ﺷﺑﻛﺔ ﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ ﺍﻷﻣﻁﺎﺭ‬
‫ﻭﺗﺻﺭﻳﻑ ﺍﻟﻣﻳﺎﻩ‪.‬‬
‫ﺍﻷﻣﻁﺎﺭ ﻭﺍﻟﻣﻳﺎﻩ ﻟﻠﻣﺩﻳﻧﺔ ﺃﻭ ﺍﻟﻘﺳﺎﺋﻡ ﺍﻟﺧﺎﺻﺔ‪.‬‬ ‫ﺍﻟﻣﻳﺎﻩ ﺍﻟﺳﻁﺣﻳﺔ‬

‫ﺧﻁﻭﻁ ﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﻣﺳﺗﻌﻣﻠﺔ ﻹﻣﺩﺍﺩ ﻭﺗﺧﺯﻳﻥ‬ ‫ﺷﺑﻛﺔ ﺍﻟﺭﻱ‬


‫ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺍﻟﻣﻌﺎﻟﺟﺔ ﻷﻏﺭﺍﺽ‬
‫ﺍﻟﺭﻱ‪.‬‬

‫ﺷﺑﻛﺔ ﺍﻷﻧﺎﺑﻳﺏ ﻭﻏﺭﻑ ﺍﻟﺗﻔﺗﻳﺵ ﺍﻟﻣﺭﺗﺑﻁﺔ ﺑﻬﺎ‬ ‫ﺍﻟﻣﺟﺭﻯ ﺍﻟﻌﻣﻭﻣﻲ‬


‫ﻭﺍﻟﻣﺳﺗﻌﻣﻠﺔ ﻟﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ‬
‫ﻭﻣﻳﺎﻩ ﺍﻷﻣﻁﺎﺭﺍﻟﺳﻁﺣﻳﺔ ﻭﺍﻷﻣﻁﺎﺭ‪.‬‬

‫ﺧﻁ ﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﺫﻱ ﻳﺭﺑﻁ ﺍﻟﻣﺑﻧﻲ ﺑﺎﻟﻣﺟﺭﻱ‬ ‫ﺍﻟﻭﺻﻠﺔ ﺍﻟﻔﺭﻋﻳﺔ‬


‫ﺍﻟﻔﺭﻋﻲ‪.‬‬

‫ﺍﻟﻣﻳﺎﺓ ﺍﻟﻐﻳﺭ ﻣﻌﺎﻟﺟﺔ ﻭﺗﺷﻣﻝ ﺃﻱ ﺳﻭﺍﺋﻝ ﺳﻭﺍء‬ ‫ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ‬


‫ﻛﺎﻧﺕ ﺗﺣﺗﻭﻱ ﻣﻭﺍﺩ ﻋﺎﻟﻘﺔ ﺍﻭ ﺧﺎﻟﻳﺔ ﻣﻧﻬﺎ‬
‫ﻭﺍﻟﺗﻲ ﻳﺗﻡ ﺻﺭﻓﻬﺎ ﻣﻥ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺳﻛﻧﻳﺔ‬
‫ﻭﺍﻟﺻﻧﺎﻋﻳﺔ ﻭﺍﻟﻣﺭﺍﻓﻖ ﺍﻟﻌﺎﻣﺔ‪.‬‬

‫ﺍﻟﻣﻳﺎﻩ ﺍﻟﺗﻲ ﺗﺗﺟﻣﻊ ﻋﻠﻰ ﺳﻁﺢ ﺍﻷﺭﺽ ﺃﻱ‬ ‫ﺍﻟﻣﻳﺎﻩ ﺍﻟﺳﻁﺣﻳﺔ‬


‫ﻛﺎﻥ ﻣﺻﺩﺭﻫﺎ‪.‬‬
‫ﺃﻱ ﺧﺯﺍﻥ ﻳﺑﻧﻰ ﺃﻭ ﻳﺭﻛﺏ ﻋﻠﻰ ﺃﻱ ﻣﺻﺭﻑ‬ ‫ﻣﺻﻳﺩﺓ ﺭﻣﻠﻳﺔ‬
‫ﺍﻟﻘﺻﺩ ﻣﻧﻪ ﺣﺟﺯ ﺍﻟﺭﻣﺎﻝ ﻭﺍﻟﻣﻭﺍﺩ ﺍﻟﺗﺭﺳﻳﺑﻳﺔ‪.‬‬

‫ﻛﻝ ﺍﻟﺗﺭﻛﻳﺑﺎﺕ ﻣﻥ ﺃﺣﻭﺍﺽ ﺍﻟﻐﺳﻳﻝ ﻭﺣﻣﺎﻣﺎﺕ‬ ‫ﺃﺟﻬﺯﺓ ﺻﺣﻳﺔ‬


‫ﻭﻣﺭﺍﺣﻳﺽ ﻭﻣﺑﺎﻭﻝ ﻭﺃﺣﻭﺍﺽ ﻣﻁﺑﺦ‬
‫ﻭﺷﻁﺎﻑ ﻭﺩﺵ‪.‬‬

‫ﺃﻱ ﻣﺣﺑﺱ ﻣﺎﺋﻲ ﻳﺗﻡ ﺗﺭﻛﻳﺑﻪ ﺑﻳﻥ ﺍﻷﺟﻬﺯﺓ‬ ‫ﻣﺣﺑﺱ ﻣﺎﺋﻲ‬


‫ﺍﻟﺻﺣﻳﺔ ﻭﺃﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ ﻟﻣﻧﻊ ﺩﺧﻭﻝ‬
‫ﺍﻟﻐﺎﺯﺍﺕ ﻭﺍﻟﺭﻭﺍﺋﺢ ﺇﻟﻰ ﺍﻟﻣﺑﻧﻰ‪.‬‬
‫ﻭﺣﺩﺓ ﺗﺭﻛﻳﺑﺔ ﺑﻬﺎ ﻣﺣﺑﺱ ﻣﺎﺋﻲ ﻭﻣﺻﻔﻲ‬ ‫ﻣﺣﺑﺱ ﻣﺎﺋﻲ ﻣﺟﺎﺭﻱ‬
‫ﺗﺗﺟﻣﻊ ﺑﻬﺎ ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﻟﺗﻧﻔﺫ ﻣﻧﻬﺎ ﺇﻟﻰ‬
‫ﻣﺻﺭﻑ ﺍﻟﻣﺟﺎﺭﻱ‪.‬‬
‫ﻣﺣﺑﺱ ﺃﺭﺿﻲ ﻋﺑﺎﺭﺓ ﻋﻥ ﻭﺣﺩﺓ ﺗﺭﻛﻳﺑﻳﺔ ﺑﻬﺎ‬ ‫ﻣﺣﺑﺱ ﻣﺎﺋﻲ ﺃﺭﺿﻲ‬
‫ﻣﺣﺑﺱ ﻣﺎﺋﻲ ﻭﻣﺻﻔﻲ ﻭﻳﺗﻡ ﺗﺭﻛﻳﺑﻬﺎ‬
‫ﺑﺎﻟﺣﻣﺎﻣﺎﺕ ﻭﺍﻟﻣﻁﺎﺑﺦ ﻟﺗﺟﻣﻳﻊ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻐﻳﺭ‬
‫ﻧﻅﻳﻔﺔ ﻭﺻﺭﻓﻬﺎ ﺇﻟﻰ ﺍﻟﻣﺣﺑﺱ ﺍﻟﺟﺎﻣﻊ‪.‬‬
‫ﺧﺯﺍﻥ ﻣﺯﻭﺩ ﺑﻣﺻﻔﻰ ﻳﺑﻧﻲ ﺃﻭ ﻳﺭﻛﺏ ﻟﻠﺗﺧﻠﺹ‬ ‫ﻣﺻﻳﺩﺓ ﺍﻟﺩﻫﻭﻥ‬
‫ﻣﻥ ﺍﻟﺩﻫﻭﻥ ﻭﺍﻟﺷﺣﻭﻡ ﻭﻓﺿﻼﺕ ﺍﻟﻣﻁﺎﺑﺦ‬
‫ﺑﻁﺭﻳﻘﺔ ﺁﻟﻳﺔ ﻭﻛﻳﻣﺎﻭﻳﺔ‪.‬‬
‫ﺧﺯﺍﻥ ﻳﺗﻡ ﺗﺷﻳﻳﺩﻩ ﻟﻠﺗﺧﻠﺹ ﻣﻥ ﻣﺧﻠﻔﺎﺕ‬ ‫ﻣﺻﻳﺩﺓ ﺍﻟﺯﻳﻭﺕ‬
‫ﺍﻟﺯﻳﻭﺕ ﻭﺍﻟﺷﺣﻭﻡ ﺍﻟﻧﺎﺗﺟﺔ ﻋﻥ ﻣﻐﺎﺳﻝ‬
‫ﺍﻟﺳﻳﺎﺭﺍﺕ ﻭﺍﻟﻭﺭﺵ‪.‬‬

‫ﺃﻱ ﻁﺭﻳﻘﺔ ﺃﻭ ﻣﺟﻣﻭﻋﺔ ﻣﻥ ﺍﻟﻁﺭﻕ ﺗﺳﺗﻌﻣﻝ‬ ‫ﻁﺭﻕ ﺍﻟﻣﻌﺎﻟﺟﺔ ﺍﻷﻭﻟﻳﺔ‬


‫ﻟﺗﻣﺭﻳﺭ ﺃﻭ ﺗﻐﻳﻳﺭ ﺍﻟﺧﺻﺎﺋﺹ ﺍﻟﻁﺑﻳﻌﻳﺔ ﺃﻭ‬
‫ﺍﻟﻛﻳﻣﺎﻭﻳﺔ ﺃﻭ ﺍﻟﺑﻳﻭﻟﻭﺟﻳﺔ ﻟﻣﻳﺎﻩ ﺍﻟﺗﺻﺭﻳﻑ‬
‫ﺑﻬﺩﻑ ﺟﻌﻠﻬﺎ ﻏﻳﺭ ﺿﺎﺭﺓ ﻟﻌﻣﻠﻳﺎﺕ ﺍﻟﻣﻌﺎﻟﺟﺔ‬
‫ﺍﻷﺧﺭﻯ ﺃﻭ ﻧﻘﻠﻬﺎ ﺇﻟﻰ ﺧﻁﻭﻁ ﺍﻟﺻﺭﻑ‬
‫ﺍﻟﺻﺣﻲ ﺍﻟﻌﻣﻭﻣﻳﺔ ﺃﻭ ﺃﻱ ﻭﺳﻳﻠﺔ ﺃﺧﺭﻯ‬
‫ﻟﻠﺻﺭﻑ‪.‬‬

‫ﺃﻱ ﺧﺯﺍﻥ ﺃﻭ ﺻﻬﺭﻳﺞ ﻣﺎﻧﻊ ﻟﻠﺗﺳﺭﺏ ﻳﺳﺗﻌﻣﻝ‬ ‫ﺧﺯﺍﻥ ﺍﻟﺗﺣﻠﻳﻝ‬


‫ﻹﺳﺗﻘﺑﺎﻝ ﻭﻣﻌﺎﻟﺟﺔ ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ‬
‫ﻭﻳﺗﻡ ﺗﺻﺭﻳﻑ ﺍﻟﻣﻳﺎﻩ ﻣﻧﻪ ﺗﻠﻘﺎﺋﻳﺎ ﺇﻟﻰ ﺧﺯﺍﻥ‬
‫ﺍﻟﺗﺻﺭﻳﻑ ﻭﺗﺳﺣﺏ ﻣﻧﻪ ﺍﻟﺭﻭﺍﺳﺏ ﺑﺻﻔﺔ‬
‫ﺩﻭﺭﻳﺔ‪.‬‬

‫ﺑﺋﺭ ﻳﺳﺗﻘﺑﻝ ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺍﻟﻣﻌﺎﻟﺟﺔ‬ ‫ﺧﺯﺍﻥ ﺍﻟﺗﺻﺭﻳﻑ‬


‫ﻣﻥ ﺧﺯﺍﻥ ﺍﻟﺗﺣﻠﻳﻝ ﻭﺗﺻﺭﻳﻔﻬﺎ ﺇﻟﻰ ﺑﺎﻁﻥ‬
‫ﺍﻻﺭﺽ‪.‬‬

‫ﻏﺭﻓﺔ ﺗﺷﻳﺩ ﻋﻠﻰ ﺍﻟﻣﺻﺭﻑ ﻳﻣﻛﻥ ﻋﻥ‬ ‫ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ‬


‫ﻁﺭﻳﻘﺗﻬﺎ ﺍﻟﺗﻔﺗﻳﺵ ﻋﻠﻰ ﺃﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ‬
‫ﺍﻟﺻﺣﻲ ﻭﻧﻅﺎﻓﺗﻬﺎ‪.‬‬

‫ﻏﺭﻓﺔ ﺗﺷﻳﺩ ﻋﻠﻰ ﺍﻟﻣﺻﺎﺭﻑ ﺍﻟﺭﺋﻳﺳﻳﺔ ﻳﻣﻛﻥ‬ ‫ﻏﺭﻓﺔ ﺗﻔﺗﻳﺵ ﺭﺋﻳﺳﻳﺔ‬


‫ﻋﻥ ﻁﺭﻳﻘﻬﺎ ﺍﻟﺗﻔﺗﻳﺵ ﻋﻠﻰ ﺃﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ‬
‫ﺍﻟﺻﺣﻲ ﻭﻧﻅﺎﻓﺗﻬﺎ‪.‬‬

‫ﺃﻱ ﺃﻧﺑﻭﺏ ﻣﺛﺑﺕ ﺭﺃﺳﻳﺎ ﺃﻭ ﺃﻓﻘﻳﺎ ﺑﻐﺭﺽ ﺣﻣﻝ‬ ‫ﺃﻧﺑﻭﺏ ﺻﺭﻑ‬


‫ﺟﻣﻳﻊ ﺃﻧﻭﺍﻉ ﺍﻟﺳﻭﺍﺋﻝ ﺍﻟﻘﺫﺭﺓ ﺍﻟﺧﺎﻟﻳﺔ ﻣﻥ‬
‫ﺍﻟﻣﺻﺭﻭﻓﺎﺕ ﺍﻟﺻﻠﺑﺔ‪.‬‬
‫ﺃﻱ ﺃﻧﺑﻭﺏ ﻣﺛﺑﺗﻪ ﺭﺃﺳﻳﺎ ﺃﻭ ﺃﻓﻘﻳﺎ ﺑﻐﺭﺽ ﺣﻣﻝ‬ ‫ﺃﻧﺑﻭﺏ ﺍﻟﻌﻣﻝ‬
‫ﺍﻟﻣﺻﺭﻭﻓﺎﺕ ﺍﻟﺻﻠﺑﺔ‪.‬‬

‫ﺃﻱ ﺃﻧﺑﻭﺏ ﻣﺭﺑﻭﻁﺔ ﻋﻠﻰ ﻣﺧﺎﺭﺝ ﺍﻷﺟﻬﺯﺓ‬ ‫ﺃﻧﺑﻭﺏ ﻣﻧﻊ ﺍﻻﻣﺗﺻﺎﺹ‬


‫ﺍﻟﺻﺣﻳﺔ ﻟﻣﻌﺎﺩﻟﺔ ﺿﻐﻁ ﺍﻟﻬﻭﺍء ﻟﻣﻧﻊ‬
‫ﺍﻣﺗﺻﺎﺹ ﺍﻟﻣﺣﺎﺑﺱ ﺍﻟﻣﺎﺋﻳﺔ‪.‬‬
‫ﺃﻱ ﺃﻧﺑﻭﺏ ﻳﺗﻡ ﺗﻣﺩﻳﺩﻩ ﺃﻓﻘﻳﺎ ﺃﻭ ﻋﻣﻭﺩﻳﺎ‬ ‫ﺃﻧﺑﻭﺏ ﺗﻬﻭﻳﺔ‬
‫ﺑﻐﺭﺽ ﺗﻬﻭﻳﺔ ﺍﻟﻣﺻﺎﺭﻑ ﻭﺍﻟﺗﻣﺩﻳﺩﺍﺕ‬
‫ﺍﻟﺻﺣﻳﺔ‪.‬‬

‫ﻛﻝ ﻧﻔﺎﻳﺎﺕ ﺍﻟﺣﻳﻭﺍﻧﺎﺕ ﻭﺍﻟﺧﺿﺭﻭﺍﺕ ﻓﻲ‬ ‫ﻧﻔﺎﻳﺎﺕ‬


‫ﺍﻟﻣﻁﺎﺑﺦ ﻭﺍﻟﻣﻳﺎﻩ ﺍﻟﻧﺎﺟﻣﺔ ﻋﻥ ﺍﻻﺳﺗﻌﻣﺎﻝ‬
‫ﺍﻟﻣﻧﺯﻟﻲ ﺃﻭ ﻣﺎ ﻳﻧﺗﺞ ﻋﻥ ﺗﺣﺿﻳﺭ ﺍﻟﻁﻌﺎﻡ ﻣﻥ‬
‫ﻣﺎ ﻳﺳﺗﻬﻠﻙ ﺑﺎﻟﻣﻧﺎﺯﻝ ﻭﺍﻷﺳﻭﺍﻕ ﻭﺍﻟﻣﺧﺗﺑﺭﺍﺕ‬
‫ﻭﺍﻟﻣﺳﺗﺷﻔﻳﺎﺕ ﻭﺍﻟﻣﺻﺎﻧﻊ ﻭﺃﻱ ﻧﻔﺎﻳﺎﺕ‬
‫ﻣﺷﺎﺑﻬﺔ ﻣﻥ ﻣﻭﺍﻗﻊ ﺃﺧﺭﻯ‪.‬‬
‫ﺃﻱ ﻣﻘﻌﺩ ﺃﻭ ﻭﻋﺎء ﻳﺳﺗﺧﺩﻡ ﻟﻘﺿﺎء ﺍﻟﺣﺎﺟﺔ‪.‬‬ ‫ﻣﺭﺣﺎﺽ‬

‫‪.‬‬ ‫ﻣﺑﻭﻟﺔ‬ ‫ﻣﺭﺣﺎﺽ ﻣﻳﺎﻩ‬

‫ﺃﻱ ﻣﻣﺭ ﺗﺣﺕ ﺍﻟﻁﺭﻳﻖ ﻳﺳﺗﻌﻣﻝ ﻟﺗﻣﺭﻳﺭﺃﻧﺎﺑﻳﺏ‬ ‫ﻋﺑﺎﺭﺓ‬


‫ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﻭﺍﻟﻣﻳﺎﻩ ﺍﻟﺳﻁﺣﻳﺔ ﻭﺧﻁﻭﻁ‬
‫ﺍﻟﺭﻱ‪.‬‬

‫ﺍﻟﺗﺄﺛﻳﺭ ﻋﻠﻰ ﺍﻟﻣﻳﺎﻩ ﺑﺻﻭﺭﺓ ﺗﺟﻌﻠﻬﺎ ﻏﻳﺭ‬ ‫ﺗﻠﻭﺙ ﺍﻟﻣﻳﺎﻩ‬


‫ﺻﺎﻟﺣﺔ ﻹﺳﺗﻌﻣﺎﻝ ﺍﻹﻧﺳﺎﻥ ﻭﺍﻟﺣﻳﻭﺍﻥ ﻭﺍﻟﻧﺑﺎﺕ‪.‬‬
‫ﺩﻭﺭﺍﺕ ﺍﻟﻣﻳﺎﻩ ﻭﺗﺷﻣﻝ ﻛﻝ ﺍﻷﺟﻬﺯﺓ ﺍﻟﺻﺣﻳﺔ‪.‬‬ ‫ﻣﻧﺎﻓﻊ ﺻﺣﻳﺔ‬
‫ﺍﻟﻔﺻﻝ ﺍﻟﺛﺎﻧﻲ‬

‫ﺷﺭﻭﻁ ﺍﻟﺑﻧﺎء‬

‫ﺷﺭﻭﻁ ﺍﻟﺑﻧﺎء‬
‫ﻳﻧﺹ ﻗﺎﻧﻭﻥ ﺍﻟﺑﻧﺎء ﻋﻠﻰ ﻣﺎ ﻳﻠﻲ‪:-‬‬
‫ﻻﻳﺟﻭﺯ ﺍﻟﺷﺭﻭﻉ ﻓﻲ ﺗﺷﻳﺩ ﺃﻱ ﺑﻧﺎء ﺃﻭ ﺇﺿﺎﻓﺔ ﺃﻭ ﻫﺩﻡ ﺃﻱ ﺟﺯء ﻣﻥ ﻣﺑﻧﻰ ﺃﻭ‬ ‫•‬

‫ﺗﻌﺩﻳﻝ ﺑﺎﻟﺑﻧﺎء ﺇﻻ ﺑﻌﺩ ﺍﻟﺣﺻﻭﻝ ﻋﻠﻰ ﺗﺭﺧﻳﺹ ﻣﻥ ﺍﻟﺳﻠﻁﺎﺕ ﺍﻟﻣﺧﺗﺻﺔ ﺑﺎﻟﺑﻠﺩﻳﺔ‪.‬‬


‫ﻻﻳﺳﻣﺢ ﺑﺈﻗﺎﻣﺔ ﺃﻱ ﻣﺑﻧﻰ ﻋﻠﻰ ﻗﻁﻌﺔ ﺃﺭﺽ ﺇﻻ ﺇﺫﺍ ﻛﺎﻥ ﻣﻁﺎﺑﻘﺎ‬ ‫•‬
‫ﻟﻠﺧﺭﻳﻁﺔ ﺍﻟﻣﻠﺣﻘﺔ ﺑﻧﻅﺎﻡ ﺗﺻﻧﻳﻑ ﻭﺗﻘﻧﻳﻥ ﺍﺳﺗﻌﻣﺎﻻﺕ ﺍﻷﺭﺍﺿﻲ‬
‫ﺍﻟﺻﺎﺩﺭﺓ ﻣﻥ ﺩﺍﺋﺭﺓ ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ ﻛﻣﺎ ﻳﻣﺗﺩ ﻋﻠﻰ ﺍﻟﺧﺭﻳﻁﺔ ﻋﺩﺩ‬
‫ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﺗﻲ ﻳﺗﻛﻭﻥ ﻣﻧﻬﺎ ﺍﻟﻣﺑﻧﻰ ﻭﻧﻭﻉ ﺍﻻﺳﺗﻌﻣﺎﻝ ﺍﻟﻣﻘﺭﺭ ﻟﻪ‬
‫ﻭﺍﺭﺗﺩﺍﺩﺗﻪ ﺍﻟﺧﺎﺭﺟﻳﺔ ﻭﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ ﺍﻟﻣﻁﻠﻭﺑﺔ‪.‬‬
‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﻬﻭﻳﺔ ﺍﻟﺛﻘﺎﻓﻳﺔ ﺍﻟﻌﺭﺑﻳﺔ ﻭﺍﻻﺳﻼﻣﻳﺔ ﻭﺍﻟﻁﺎﺑﻊ ﺍﻟﻣﻌﻣﺎﺭﻱ‬ ‫•‬

‫ﺍﻟﻣﺣﻠﻲ ‪.‬ﻭﺍﻧﺳﺟﺎﻡ ﻭﺗﻭﺍﻓﻖ ﺍﻷﻟﻭﺍﻥ ﻣﻊ ﺍﻟﺑﻳﺋﺔ ﺍﻟﻣﺣﻳﻁﺔ ﻋﻧﺩ ﺇﻋﺩﺍﺩ‬


‫ﺍﻟﺗﺻﻣﻳﻡ‪.‬‬
‫ﺍﻟﺗﺭﺧﻳﺹ ﺍﻹﺑﺗﺩﺍﺋﻲ‬ ‫•‬
‫ﻳﻘﺩﻡ ﻁﻠﺏ ﺗﺭﺧﻳﺹ ﺍﻟﺑﻧﺎء ﺍﻹﺑﺗﺩﺍﺋﻲ ﻭﻓﻘﺎ ﻟﻺﺟﺭﺍءﺍﺕ ﺍﻟﻣﺗﺑﻌﺔ ﻋﻠﻰ‬
‫ﺃﻥ ﻳﺭﻓﻖ ﺑﻪ ﺍﻟﺗﺎﻟﻲ‪:-‬‬
‫ﻣﺧﻁﻁ ﺍﻷﺭﺽ ﺍﻟﻣﻌﺗﻣﺩ ﻣﻥ ﺩﺍﺋﺭﺓ ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ‪.‬‬ ‫•‬

‫ﺻﻭﺭﺓ ﻣﻥ ﺭﺧﺻﺔ ﺍﻹﺳﺗﺷﺎﺭﻱ‪.‬‬ ‫•‬

‫ﻋﺩﺩ ‪ 2‬ﻧﺳﺧﺔ ﻣﻥ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻟﻣﻌﻣﺎﺭﻳﺔ ﻣﺗﺿﻣﻧﺔ ﺍﻟﺗﺎﻟﻲ‪:‬‬ ‫•‬

‫ﻣﺧﻁﻁ ﺍﻟﻣﻭﻗﻊ ﺍﻟﻌﺎﻡ ﺑﻣﻘﻳﺎﺱ ﺭﺳﻡ ﻣﻧﺎﺳﺏ ﺗﺣﺩﺩﻩ ﻣﺳﺎﺣﺔ‬ ‫•‬


‫ﺍﻟﻘﻁﻌﺔ ﻣﺑﻳﻧﺎ ﻋﻠﻳﻪ ﻣﻭﻗﻊ ﺍﻟﺑﻧﺎء ﺍﻟﻣﻘﺗﺭﺡ ﻭﺃﻳﺔ ﻣﺑﺎﻧﻲ ﺃﺧﺭﻯ‬
‫ﻗﺎﺋﻣﺔ ﺇﻥ ﻭﺟﺩﺕ ﻛﻣﺎ ﻳﺑﻳﻥ ﺑﻪ ﺃﺑﻌﺎﺩ ﺍﻹﺭﺗﺩﺍﺩﺍﺕ ﻭﺳﻣﻙ ﺍﻟﺳﻭﺭ‬
‫ﺍﻟﺧﺎﺭﺟﻲ ﻭﻣﻭﻗﻊ ﻭﻋﺭﺽ ﺃﺑﻭﺍﺏ ﺍﻟﺳﻭﺭ ﻭﻣﻭﻗﻊ ﻭﻣﺳﺎﺭ‬
‫ﺍﻟﺧﺩﻣﺎﺕ ﺑﺎﻟﻘﻁﻌﺔ ﻭﺟﻣﻳﻊ ﺍﻟﺷﻭﺍﺭﻉ ﺃﻭ ﺍﻟﻘﻁﻊ ﺍﻟﻣﺟﺎﻭﺭﺓ‬
‫ﺍﻷﺧﺭﻯ ﻛﻣﺎ ﻳﺷﺗﺭﻁ ﺗﻭﺿﻳﺢ ﺣﺳﺎﺑﺎﺕ ﻧﺳﺑﺔ ﺍﻟﺑﻧﺎء‬
‫ﻭﺍﻟﻧﺳﺑﺔ ﺍﻟﻁﺎﺑﻘﻳﺔ( ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺃﻛﺛﺭ ﻣﻥ ﺩﻭﺭ ) ﻭﺗﺣﺩﻳﺩ‬
‫ﺍﺗﺟﺎﻩ ﺍﻟﺷﻣﺎﻝ‪.‬‬

‫ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻟﻣﻌﻣﺎﺭﻳﺔ ﺑﻣﻘﻳﺎﺱ ﻻ ﻳﻘﻝ ﻋﻥ)‪ (1:100‬ﻣﻭﺿﺣﺎ‬ ‫•‬

‫ﻓﻳﻬﺎ ﺍﻟﺗﺎﻟﻲ‪:‬‬
‫ﻣﺳﻘﻁ ﺃﻓﻘﻲ ﻟﻛﻝ ﻁﺎﺑﻖ ﻣﻭﺿﺣﺎ ﻋﻠﻳﻪ ﺳﻣﻙ ﺍﻟﺣﻭﺍﺋﻁ ﺍﻟﺧﺎﺭﺟﻳﺔ‬ ‫•‬
‫ﻭﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﺍﻟﻔﺗﺣﺎﺕ ﻭﺃﺑﻌﺎﺩ ﻭﺍﺳﺗﻌﻣﺎﻻﺕ ﻛﻝ ﺍﻟﻌﻧﺎﺻﺭ ﻭﺍﻟﻭﺣﺩﺍﺕ‬
‫ﻭﺍﻟﻔﺭﺍﻏﺎﺕ ﺍﻟﻣﻛﻭﻧﺔ ﻟﻠﻁﺎﺑﻖ‪.‬‬

‫ﻣﺳﺎﻗﻁ ﺭﺃﺳﻳﺔ )ﻭﺍﺟﻬﺎﺕ( ﻣﻭﺿﺣﺎ ﺑﻬﺎ ﺍﻟﻔﺗﺣﺎﺕ ﻭﺍﻟﺑﺭﻭﺯﺍﺕ ﻛﺫﻟﻙ‬ ‫•‬

‫ﺟﻣﻳﻊ ﺍﻟﺗﻔﺎﺻﻳﻝ ﺍﻟﻼﺯﻣﺔ‪.‬‬

‫ﻗﻁﺎﻉ ﺭﺃﺳﻲ ﻣﻌﻣﺎﺭﻱ ﻳﻣﺭ ﺑﺄﻋﻠﻰ ﻣﻧﺳﻭﺏ ﻓﻳﻪ ﺣﺗﻰ ﻣﻧﺳﻭﺏ‬ ‫•‬
‫ﺳﻁﺢ ﺍﻷﺭﺽ ﻣﻭﺿﺣﺎ ﻋﻠﻳﻪ ﻣﻧﺎﺳﻳﺏ ﺍﻷﺳﻘﻑ ﻭﺍﻟﻔﺗﺣﺎﺕ‬
‫ﻭﺍﻷﺭﺿﻳﺎﺕ ﻭﻳﻣﻛﻥ ﻟﻠﺟﻬﺎﺕ ﺍﻟﻣﺧﺗﺻﺔ ﺑﺎﻟﺑﻠﺩﻳﺔ ﻁﻠﺏ ﺃﻛﺛﺭ ﻣﻥ‬
‫ﻗﻁﺎﻉ ﻓﻲ ﺣﺎﻟﺔ ﺗﻁﻠﺏ ﺍﻷﻣﺭ ﺫﻟﻙ‪.‬‬

‫ﻭﻳﻛﺗﻔﻲ ﺑﻌﻣﻝ ﺟﺩﺍﻭﻝ ﻟﻸﺑﻌﺎﺩ ﻟﺟﻣﻳﻊ ﺍﻟﻔﺋﺎﺕ )ﺍﻷﺑﻭﺍﺏ‪ ،‬ﺍﻟﻧﻭﺍﻓﺫ( ﻭﻳﻠﺯﻡ ﺗﻘﺩﻳﻡ‬
‫ﺭﺳﻭﻣﺎﺕ ﻣﻌﻣﺎﺭﻳﺔ ﻟﺗﻠﻙ ﺍﻟﻔﺋﺎﺕ ﻓﻲ ﺣﺎﻟﺔ ﺗﻁﻠﺏ ﺍﻷﻣﺭ ﺫﻟﻙ‪.‬‬

‫‪(3‬ﺍﻟﺗﺭﺧﻳﺹ ﺍﻟﻧﻬﺎﺋﻲ‪:‬‬
‫ﻳﻘﺩﻡ ﻁﻠﺏ ﺍﻟﺗﺭﺧﻳﺹ ﺍﻟﻧﻬﺎﺋﻲ ﻭﻓﻘﺎ ﻟﻺﺟﺭﺍءﺍﺕ ﺍﻟﻣﺗﺑﻌﺔ ﻋﻠﻰ ﺃﻥ ﻳﺭﻓﻖ‬
‫ﺑﻪ ﺍﻟﺗﺎﻟﻲ‪:‬‬
‫ﻣﻭﺍﻓﻘﺎﺕ ﺩﻭﺍﺋﺭ ﺍﻟﺧﺩﻣﺎﺕ ﺍﻟﻣﺣﻠﻳﺔ ﻭﺍﻻﺗﺣﺎﺩﻳﺔ‪.‬‬ ‫•‬
‫ﻋﻘﺩ ﺍﻟﻣﻘﺎﻭﻝ‪.‬‬ ‫•‬

‫ﻋﻘﺩ ﺍﻹﺳﺗﺷﺎﺭﻱ‪.‬‬ ‫•‬


‫ﺭﺳﺎﻟﺔ ﺍﻻﺷﺭﺍﻑ‪.‬‬ ‫•‬
‫ﺻﻭﺭﺓ ﻣﻥ ﺭﺧﺻﺔ ﺍﻟﻣﻘﺎﻭﻝ ﺳﺎﺭﻳﺔ ﺍﻟﻣﻔﻌﻭﻝ‪.‬‬ ‫•‬
‫ﺻﻭﺭﺓ ﻣﻥ ﺭﺧﺻﺔ ﺍﻹﺳﺗﺷﺎﺭﻱ ﺳﺎﺭﻳﺔ ﺍﻟﻣﻔﻌﻭﻝ‪.‬‬ ‫•‬
‫ﺻﻭﺭﺓ ﺳﺎﺭﻳﺔ ﻣﻥ ﻣﺧﻁﻁ ﺍﻷﺭﺽ‪.‬‬ ‫•‬
‫ﺗﻘﺭﻳﺭ ﻋﻥ ﻓﺣﺹ ﺍﻟﺗﺭﺑﺔ‪.‬‬ ‫•‬
‫ﻋﺩﺩ ‪ 3‬ﻧﺳﺦ ﻣﻥ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻟﻧﻬﺎﺋﻳﺔ ﻭﻧﺳﺧﺔ ﺇﻟﻛﺗﺭﻭﻧﻳﺔ )‪(CD‬‬ ‫•‬
‫ﻣﺗﺿﻣﻧﺔ ﺍﻟﺗﺎﻟﻲ‪:-‬‬
‫ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻟﻣﻌﻣﺎﺭﻳﺔ ﺍﻟﻣﺷﺎﺭ ﺇﻟﻳﻬﺎ ﺑﺎﻟﻣﺎﺩﺓ ﺍﻟﺳﺎﺑﻘﺔ‬ ‫•‬
‫ﻣﺗﺿﻣﻧﺔ ﺍﻟﺗﻌﺩﻳﻼﺕ ﻓﻲ)ﺣﺎﻝ ﻭﺟﻭﺩﻫﺎ(‪.‬‬
‫ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻹﻧﺷﺎﺋﻳﺔ ﺑﻣﻘﻳﺎﺱ ﻻ ﺗﻘﻝ ﻋﻥ )‪(100:1‬‬ ‫•‬
‫ﻣﻌﺗﻣﺩﺓ ﻭﻣﻭﻗﻊ ﻋﻠﻳﻬﺎ ﻣﻥ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﻧﺷﺎﺋﻲ ﻟﻠﻣﻛﺗﺏ‬
‫ﺍﻹﺳﺗﺷﺎﺭﻱ ﻣﺗﺿﻣﻧﺔ ﺍﻟﺗﺎﻟﻲ‪:‬‬
‫• ﻣﺳﻘﻁ ﺃﻓﻘﻲ ﻟﻸﺳﺎﺳﺎﺕ ﻭﺍﻷﻋﻣﺩﺓ ﻭﺍﻟﺟﺳﻭﺭ ﻣﻭﺿﺣﺎ‬
‫ﻋﻠﻳﻬﺎ ﺍﻷﺑﻌﺎﺩ ﺍﻟﻼﺯﻣﺔ ﻛﺫﻟﻙ ﺟﺩﺍﻭﻝ ﺍﻟﺣﺳﺎﺑﺎﺕ‬
‫ﺍﻟﺧﺎﺻﺔ ﺑﻬﺎ‪.‬‬
‫• ﻣﺧﻁﻁﺎﺕ ﻟﻘﻁﺎﻋﺎﺕ ﻣﻔﺻﻠﺔ ﻟﻠﺟﺳﻭﺭ ﻭﺍﻷﻋﻣﺩﺓ‬
‫ﻭﺍﻷﺳﺎﺳﺎﺕ ﻭﺍﻟﺳﻼﻟﻡ ﻭﺑﻼﻁﺎﺕ ﺍﻟﺳﻘﻑ ﻛﺫﻟﻙ ﻳﻠﺯﻡ‬
‫ﺗﻘﺩﻳﻡ ﺣﺳﺎﺑﺎﺕ ﺍﻟﺗﺣﻠﻳﻝ ﺍﻹﻧﺷﺎﺋﻲ )‪ (CD‬ﻭﻣﺫﻛﺭﺓ‬
‫ﻟﻠﺣﺳﺎﺑﺎﺕ ﺍﻹﻧﺷﺎﺋﻳﺔ ﻣﻭﺿﺣﺎ ﻋﻠﻳﻬﺎ ﻛﺎﻓﺔ‬
‫ﺍﻟﺗﻔﺎﺻﻳﻝ ﺍﻟﻣﺗﻌﻠﻘﺔ ﺑﺗﻠﻙ ﺍﻟﺣﺳﺎﺑﺎﺕ‪.‬‬
‫ﻣﺧﻁﻁﺎﺕ ﺑﻣﻘﻳﺎﺱ ﺭﺳﻡ ﻻ ﻳﻘﻝ ﻋﻥ )‪ (100:1‬ﻟﻠﻣﺳﺎﻗﻁ‬ ‫•‬
‫ﺍﻻﻓﻘﻳﺔ ﻟﻠﺗﻭﺻﻳﻼﺕ ﺍﻟﻛﺭﺑﺎﺋﻳﺔ ﻛﺫﻟﻙ ﺍﻟﺟﺩﺍﻭﻝ ﺍﻟﻣﻭﺿﺣﺔ‬
‫ﻟﻛﺎﻓﺔ ﺍﻷﺣﻣﺎﻝ‪.‬‬
‫ﻣﺧﻁﻁﺎﺕ ﺑﻣﻘﻳﺎﺱ ﺭﺳﻡ ﻻﻳﻘﻝ ﻋﻥ )‪ (100:1‬ﻟﻠﻣﺳﺎﻗﻁ‬ ‫•‬
‫ﺍﻷﻓﻘﻳﺔ ﻣﺑﻳﻧﺎ ﻋﻠﻳﻬﺎ ﻣﺳﺎﺭﺍﺕ ﺧﻁﻭﻁ ﺍﻟﺗﻐﺫﻳﺔ ﻭﺍﻟﺻﺭﻑ‬
‫ﺍﻟﺻﺣﻲ ﻭﻣﻳﻭﻝ ﺍﻷﺳﻁﺢ ﻭﺍﻷﺭﺿﻳﺎﺕ ﻟﻠﺗﺧﻠﺹ ﻣﻥ ﻣﻳﺎﻩ‬
‫ﺍﻷﻣﻁﺎﺭ ﻛﺫﻟﻙ ﻣﺧﻁﻁﺎﺕ ﺗﻔﺎﺻﻳﻝ ﺧﺯﺍﻥ ﺍﻟﺗﺣﻠﻳﻝ ﻭﻏﺭﻑ‬
‫ﺍﻟﺗﻔﺗﻳﺵ ﻭﻣﺎ ﺇﻟﻰ ﺫﻟﻙ‪.‬‬
‫ﻣﺧﻁﻁﺎﺕ ﺗﻭﺿﺢ ﺗﻘﺎﻁﻊ ﺍﻷﺳﻭﺍﺭ ﻭﺗﻔﺎﺻﻳﻠﻬﺎ ‪.‬‬ ‫•‬

‫‪ (4‬ﻳﺟﺏ ﺃﻥ ﻳﺗﻡ ﺭﺳﻡ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺑﺎﻟﻁﺭﻳﻘﺔ ﺍﻟﻔﻧﻳﺔ ﺍﻟﺻﺣﻳﺣﺔ ﻭﺃﻥ ﻳﻛﻭﻥ‬


‫ﺍﻟﺭﺳﻡ ﺫﺍ ﻣﺳﺗﻭﻯ ﺟﻳﺩ ﻭﻭﺍﺿﺢ ﻭﺃﻥ ﺗﻛﻭﻥ ﺃﺣﺟﺎﻡ ﺍﻟﺧﺭﺍﺋﻁ ﺣﺳﺏ‬
‫ﺍﻟﻣﻘﺎﺳﺎﺕ ﻭﺍﻷﺣﺟﺎﻡ ﺍﻟﻔﻧﻳﺔ ﺍﻟﻣﺗﻌﺎﺭﻑ ﻋﻠﻳﻬﺎ ﻛﻣﺎ ﻳﺟﺏ ﺃﻥ ﻳﺗﻡ ﺗﻭﺯﻳﻊ‬
‫ﺍﻟﻣﺧﻁﻁﺎﺕ ﺑﻬﺎ ﺑﻁﺭﻳﻘﺔ ﻋﻠﻣﻳﺔ ﻣﻘﺑﻭﻟﺔ‪.‬‬
‫ﺍﻟﻔﺻﻝ ﺍﻟﺛﺎﻟﺙ‬

‫ﺍﻟﺷﺭﻭﻁ ﺍﻟﻔﻧﻳﺔ‬
‫ﻟﻠﻣﺑﺎﻧﻲ‬

‫ﺍﻹﺭﺗﺩﺍﺩﺍﺕ‬ ‫•‬
‫• ﺗﺣﺩﺩ ﺍﻹﺭﺗﺩﺍﺩﺍﺕ ﺣﺳﺏ ﻧﻭﻉ ﺍﻻﺳﺗﻌﻣﺎﻝ ﻛﻣﺎ ﻫﻭ ﻣﻭﺿﺢ‬
‫ﺑﺎﻟﺟﺩﺍﻭﻝ ﺍﻟﺗﺎﻟﻳﺔ‪:‬‬
‫ﺍﻟﻣﻧﺎﻁﻖ ﺍﻟﻣﺧﺻﺻﺔ ﻟﻼﺳﺗﻌﻣﺎﻝ ﺍﻟﺳﻛﻧﻲ‪:‬‬ ‫•‬
‫ﺍﻟﺳﻛﺔ‪/‬ﻡ‬ ‫ﺍﻟﺟﺎﺭ‪/‬ﻡ‬ ‫ﺍﻟﺷﺎﺭﻉ‬
‫‪1.50‬‬ ‫‪3.00‬‬ ‫‪5.00‬‬ ‫ﺍﻟﻔﻳﻼ‬
‫‪1.50‬‬ ‫‪1.50‬‬ ‫‪2.50‬‬ ‫ﺍﻟﻣﻠﺣﻖ‬
‫ﺍﻟﻣﻧﺎﻁﻖ ﺍﻟﻣﺧﺻﺻﺔ ﻟﻼﺳﺗﻌﻣﺎﻻﺕ ﺍﻟﺻﻧﺎﻋﻳﺔ‪:‬‬ ‫•‬
‫ﺍﻟﺳﻛﺔ‪/‬ﻡ‬ ‫ﺍﻟﺟﺎﺭ‪/‬ﻡ‬ ‫ﺍﻟﺷﺎﺭﻉ‬
‫‪5.00‬‬ ‫‪5.00‬‬ ‫‪5.00‬‬ ‫ﺍﻟﺷﺑﺭﺍﺕ‬
‫‪5.00‬‬ ‫‪5.00‬‬ ‫‪5.00‬‬ ‫ﺳﻛﻥ ﺍﻟﻌﻣﺎﻝ‬
‫ﻻ ﻳﻭﺟﺩ)ﻋﻠﻰ ﺣﺩ ﺍﻟﻘﻁﻌﺔ‬
‫ﺍﻟﻣﻁﻠﺔ ﻋﻠﻰ ﺍﻟﺷﺎﺭﻉ ﺣﻳﺙ‬
‫‪5.00‬‬ ‫‪5.00‬‬ ‫ﺍﻟﻣﻛﺎﺗﺏ ﻭﺍﻟﻣﺣﻼﺕ‬
‫ﻳﺷﺗﺭﻁ ﺃﻥ ﺗﻛﻭﻥ ﺍﻟﻭﺍﺟﻬﺎﺕ‬
‫ﺫﺍﺕ ﻗﻳﻣﺔ ﻣﻌﻣﺎﺭﻳﺔ(‬

‫ﺍﻟﻣﻧﺎﻁﻖ ﺍﻟﻣﺧﺻﺻﺔ ﻟﻼﺳﺗﻌﻣﺎﻝ ﺍﻟﺳﻛﻧﻲ ﺍﻟﺗﺟﺎﺭﻱ‪:‬‬ ‫•‬


‫ﺍﻟﺳﻛﺔ‪/‬ﻡ‬ ‫ﺍﻟﺟﺎﺭ‪/‬ﻡ‬ ‫ﺍﻟﺷﺎﺭﻉ‬
‫ﻻ ﻳﻭﺟﺩ )ﻋﻠﻰ ﺣﺩ‬
‫ﺍﻟﻘﻁﻌﺔ ﺍﻟﻣﻁﻠﺔ‬
‫ﻋﻠﻰ ﺍﻟﺷﺎﺭﻉ ﺣﻳﺙ‬
‫ﻻﻳﻭﺟﺩ‬ ‫‪3.00‬‬ ‫ﺍﻟﻣﺣﻼﺕ ﺍﻟﺗﺟﺎﺭﻳﺔ‬
‫ﻳﺷﺗﺭﻁ ﺃﻥ ﺗﻛﻭﻥ‬
‫ﺍﻟﻭﺍﺟﻬﺎﺕ ﺫﺍﺕ‬
‫ﻗﻳﻣﺔ ﻣﻌﻣﺎﺭﻳﺔ(‬
‫ﺍﻟﺑﻧﺎﻳﺎﺕ ﺍﻟﺳﻛﻧﻳﺔ‬
‫‪1.50‬‬ ‫‪3.00‬‬ ‫ﺍﻟﺗﺟﺎﺭﻳﺔ ﺣﺗﻰ ﻻ ﻳﻭﺟﺩ‬
‫ﺃﺭﺿﻲ ‪ +5‬ﺃﺩﻭﺍﺭ‬
‫‪2‬ﻡ ﻓﻲ ﺣﺎﻟﺔ‬
‫ﺍﻟﺑﻧﺎﻳﺎﺕ ﺍﻟﺳﻛﻧﻳﺔ‬
‫ﻋﺭﺽ ﺍﻟﺳﻛﺔ‪ 6‬ﻡ‬
‫‪4.50‬‬ ‫ﺍﻟﺗﺟﺎﺭﻳﺔ ﺃﺭﺿﻲ ﻻ ﻳﻭﺟﺩ‬
‫‪3‬ﻡ ﻓﻲ ﺣﺎﻟﺔ‬
‫‪+6‬ﺃﺩﻭﺍﺭ ﺃﻭ ﺃﻛﺛﺭ‬
‫ﻋﺭﺽ ﺍﻟﺳﻛﺔ‪ 3‬ﻡ‬
‫• ﻳﺟﺏ ﺃﻥ ﻻ ﺗﻘﻝ ﺍﻟﻣﺳﺎﻓﺔ ﺑﻳﻥ ﺍﻟﻣﺑﻧﻰ ﺍﻟﺭﺋﻳﺳﻲ ﻭﺍﻟﻣﺑﻧﻰ ﻋﻥ)‪ 3‬ﻡ(‪.‬‬
‫ﻣﻼﺣﻅﺔ ‪ :‬ﻳﻣﻛﻥ ﺃﻥ ﺗﻛﻭﻥ ﻫﻧﺎﻙ ﺇﺳﺗﺛﻧﺎءﺍﺕ ﺣﺳﺏ ﻣﺳﺎﺣﺔ ﻭﻅﺭﻭﻑ ﻗﻁﻌﺔ ﺍﻷﺭﺽ‬
‫ﻟﺑﻌﺽ ﺍﻟﻣﻧﺎﻁﻖ ﺑﻌﺩ ﺃﺧﺫ ﻣﻭﺍﻓﻘﺔ ﺩﺍﺋﺭﺓ ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ‪.‬‬
‫ﻻ ﻳﺻﺭﺡ ﺑﺎﻟﺑﻧﺎء ﻷﻱ ﺇﻧﺷﺎءﺍﺕ ﻓﻲ ﺍﻹﺭﺗﺩﺍﺩﺍﺕ ﻷﻱ ﻣﺑﻧﻰ ﺑﺈﺳﺗﺛﻧﺎء‬ ‫•‬
‫ﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ ﺍﻟﻣﻛﺷﻭﻓﺔ‪.‬‬
‫ﻻ ﻳﺻﺭﺡ ﺑﺄﻱ ﺑﺭﻭﺯﺍﺕ ﻓﻲ ﺍﻹﺭﺗﺩﺍﺩﺕ ﻋﺩﺍ ﺍﻟﺑﺭﻭﺯ ﺍﻟﺯﺧﺭﻓﻲ‬ ‫•‬
‫ﻭﻳﻛﻭﻥ ﺑﻣﻘﺩﺍﺭ )‪30‬ﺳﻡ( ﻛﺣﺩ ﺃﻗﺻﻰ ﻟﻣﻌﺎﻟﺟﺔ ﺍﻟﻭﺍﺟﻬﺎﺕ ﺑﺣﻳﺙ ﻳﻛﻭﻥ‬
‫ﺃﻋﻠﻰ ﻣﻥ ﺟﻠﺳﺔ ﺍﻟﺷﺑﺎﻙ ﻭﻳﻣﻛﻥ ﺍﻟﺑﺭﻭﺯ ﺑﻣﻘﺩﺍﺭ)‪ 90‬ﺳﻡ ( ﻓﻲ ﺍﻟﺑﺎﺭﺑﻳﺕ‬
‫ﻛﺣﺩ ﺃﻗﺻﻰ‪.‬‬
‫ﻳﺻﺭﺡ ﺑﻌﻣﻝ ﺑﺭﻭﺯﺍﺕ ﻓﻲ ﺍﻷﺩﻭﺍﺭ ﺍﻟﻣﺗﻛﺭﺭﺓ ﺑﺎﻟﻧﺳﺑﺔ ﻟﻼﺳﺗﻌﻣﺎﻝ‬ ‫•‬
‫ﺍﻟﺳﻛﻧﻲ ﺍﻟﺗﺟﺎﺭﻱ ﺑﻣﻘﺩﺍﺭ ﻻ ﻳﺯﻳﺩ ﻋﻥ)‪ 120‬ﺳﻡ( ﻣﻥ ﺟﻬﺔ ﺍﻟﺷﻭﺍﺭﻉ‬
‫ﻭﺫﻟﻙ ﺗﺑﻌﺎ ﻟﻣﺣﺩﺩﺍﺕ ﺩﺍﺋﺭﺓ ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ ‪ ،‬ﺑﺷﺭﻁ ﺃﻥ ﻳﻛﻭﻥ‬
‫ﺍﻟﺣﺩ ﺍﻟﺻﺎﻓﻲ ﻻﺭﺗﻔﺎﻉ ﺍﻟﺷﺭﻓﺔ ﻋﻥ ﻣﺳﺗﻭﻱ ﺍﻟﺭﺻﻳﻑ ﺍﻟﻣﻣﻬﺩ ﻻ ﻳﻘﻝ‬
‫ﻋﻥ )‪3‬ﻡ(‪.‬‬

‫ﻣﺑﺎﻧﻲ ﺍﻟﺳﻛﻥ ﻋﻠﻰ ﺍﻟﻁﺭﺍﺯ ﺍﻟﺷﺭﻗﻲ‪.‬‬ ‫•‬

‫• ﻳﺳﻣﺢ ﺑﺎﻟﺑﻧﺎء ﻋﻠﻰ ﺍﻟﻁﺭﺍﺯ ﺍﻟﺷﺭﻗﻲ ﻣﻊ ﺍﻻﻟﺗﺯﺍﻡ ﺑﻌﻣﻝ ﺣﻭﺵ ﺃﻭ‬


‫ﻓﻧﺎء ﺩﺍﺧﻠﻲ ﺗﻁﻝ ﻋﻠﻳﻪ ﻏﺭﻑ ﻭﺧﺩﻣﺎﺕ ﺍﻟﻣﺑﻧﻰ ﻋﻠﻰ ﺃﻥ ﻻ ﻳﻘﻝ ﺃﻱ‬
‫ﻣﻥ ﺃﺑﻌﺎﺩ ﺍﻟﻔﻧﺎء ﻋﻥ ‪ 4‬ﺃﻣﺗﺎﺭ‪.‬‬
‫• ﻻ ﻳﺳﻣﺢ ﺑﺗﺳﻘﻳﻑ ﺃﻭ ﺗﻐﻁﻳﺔ ﺍﻟﻔﻧﺎء ﺍﻟﺩﺍﺧﻠﻲ‪.‬‬
‫• ﺗﻛﻭﻥ ﺍﻹﺭﺗﺩﺍﺩﺍﺕ ﻓﻲ ﺿﻭء ﺍﻷﺣﻛﺎﻡ ﺍﻟﺧﺎﺻﺔ ﺑﻛﻝ ﻣﻧﻁﻘﺔ‪.‬‬
‫• ﻣﺳﺎﺣﺎﺕ ﺍﻟﻐﺭﻑ ﻭﺍﻟﻣﺭﺍﻓﻖ ﻭﺃﺑﻌﺎﺩﻫﺎ‪.‬‬
‫• ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﺳﻣﻙ ﺍﻟﺣﻭﺍﺋﻁ ﺍﻟﺧﺎﺭﺟﻳﺔ ﻷﻱ ﻣﺑﻧﻰ ﻋﻥ ‪ 20‬ﺳﻡ ﻛﺫﻟﻙ‬
‫ﺍﻟﺣﻭﺍﺋﻁ ﺍﻟﻔﺎﺻﻠﺔ ﺑﻳﻥ ﻭﺣﺩﺗﻳﻥ ﺳﻛﻧﻳﺗﻳﻥ ﺃﻭ ﺑﻳﻥ ﻏﺭﻓﺔ ﺍﻟﻣﻌﻳﺷﺔ‬
‫ﻟﻸﺳﺭﺓ ﻭﻏﺭﻓﺔ ﺍﻟﺿﻳﻭﻑ ﺩﺍﺧﻝ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺳﻛﻧﻳﺔ ﻟﻣﻧﻊ ﺍﻧﺗﻘﺎﻝ ﺍﻟﺻﻭﺕ‬
‫ﺃﻭ ﺗﺧﻔﻳﻔﻪ‪.‬‬
‫• ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻟﻣﺳﺎﺣﺎﺕ ﺍﻟﻐﺭﻑ ﻭﺃﺑﻌﺎﺩﻫﺎ ﺑﺎﻟﻣﺑﺎﻧﻲ ﻭﻣﺧﺗﻠﻑ ﻣﺭﺍﻓﻖ‬
‫ﺍﻟﺑﻧﺎء ﻭﻓﻘﺎ ﻟﻠﺟﺩﻭﻝ ﺍﻵﺗﻲ‪:‬‬
‫ﺍﻟﺣﺩ ﺍﻻﺩﻧﻲ ﻟﻠﻣﺳﺎﺣﺔ ﺍﻟﺣﺩ ﺍﻻﺩﻧﻲ ﻻﻳﻘﻝ ﻋﻥ‬
‫ﻡ ﻧﻭﻉ ﺍﻻﺳﺗﻌﻣﺎﻝ‬
‫)ﻣﺗﺭ ﻁﻭﻟﻲ(‬ ‫)ﺑﺎﻟﻣﺗﺭ ﺍﻟﻣﺭﺑﻊ(‬

‫‪3.00‬‬ ‫‪12.00‬‬ ‫‪ 1‬ﺍﻟﻐﺭﻓﺔ ﺍﻟﺳﻛﻧﻳﺔ‬


‫‪2.00‬‬ ‫‪5.00‬‬ ‫‪ 2‬ﺍﻟﻣﻁﺑﺦ‬
‫‪1.8‬‬ ‫‪4.00‬‬ ‫‪ 3‬ﺍﻟﺣﻣﺎﻡ ﺍﻟﻛﺎﻣﻝ‬
‫‪ 4‬ﺩﻭﺭﺓ‬
‫‪1.00‬‬ ‫‪1.65‬‬
‫ﺍﻟﻣﻳﺎﻩ)ﻣﺭﺣﺎﺽ(‬
‫‪2.70‬‬ ‫‪10.00‬‬ ‫‪ 5‬ﺍﻟﻣﻛﺗﺏ‬
‫‪3.00‬‬ ‫‪12.00‬‬ ‫‪ 6‬ﺍﻟﻣﺣﻝ ﺍﻟﺗﺟﺎﺭﻱ‬
‫‪3.00‬‬ ‫‪ 7‬ﻣﻭﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ ‪15.00‬‬
‫• ﺗﺣﺩﺩ ﻣﺳﺎﺣﺎﺕ ﺍﻟﻐﺭﻑ ﺑﻣﺑﺎﻧﻲ ﺍﻟﻣﺭﺍﻓﻖ ﺍﻟﻌﺎﻣﺔ ﻛﺎﻟﻣﺩﺍﺭﺱ ﻭﺍﻟﻣﺳﺗﺷﻔﻳﺎﺕ‬
‫ﻭﺍﻟﻔﻧﺎﺩﻕ ﻭﻣﺎﻓﻲ ﺣﻛﻣﻬﺎ ﻭﻓﻘﺎ ﻟﻠﻘﻳﺎﺳﺎﺕ ﺍﻟﻌﺎﻟﻣﻳﺔ ﺍﻟﻣﺗﻌﺎﺭﻑ ﻋﻠﻳﻬﺎ‪.‬‬
‫ﻳﺟﻭﺯ ﺇﺳﺗﺛﻧﺎء ﻏﺭﻑ ﺍﻟﺣﺎﺭﺱ ﺃﻭ ﺍﻟﺧﺎﺩﻡ ﺃﻭ ﻣﻁﺑﺦ ﺻﻐﻳﺭ ﻟﺧﺩﻣﺔ ﻣﻛﺗﺏ‬ ‫•‬
‫ﺃﻭ ﻣﺎﻓﻲ ﺣﻛﻡ ﺫﻟﻙ ﻣﻥ ﺍﻷﺣﻛﺎﻡ ﺍﻟﻣﺑﻧﻳﺔ ﺑﺎﻟﻔﻘﺭﺓ)‪.(2‬‬

‫ﺍﻟﻣﻼﺣﻖ ﺑﺎﻷﺭﺍﺿﻲ ﺍﻟﺳﻛﻧﻳﺔ‪:‬‬ ‫•‬


‫ﻳﺻﺭﺡ ﺑﺈﻗﺎﻣﺔ ﻣﻼﺣﻖ ﺇﺿﺎﻓﻳﺔ ﺗﺎﺑﻌﺔ ﻟﻠﻔﻠﻝ ﺍﻟﺳﻛﻧﻳﺔ ﺑﺈﺭﺗﻔﺎﻉ ﺃﺭﺿﻲ‬ ‫•‬
‫ﺷﺭﻳﻁﺔ ﻣﺭﺍﻋﺎﺓ ﺍﻹﺭﺗﺩﺍﺩﺍﺕ ﺍﻟﻣﻣﺗﺩﺓ ﻛﺫﻟﻙ ﺃﻥ ﻳﻛﻭﻥ ﺑﺷﻛﻝ ﺷﺭﻳﻁﻲ‬
‫ﻣﻭﺍﺯﻱ ﻟﻠﺳﻭﺭ‪.‬‬
‫ﻳﺣﺩﺩ ﺍﺳﺗﻌﻣﺎﻝ ﺍﻟﻣﻼﺣﻖ ﻟﻸﻏﺭﺍﺽ ﺍﻟﺧﺩﻣﻳﺔ ﻟﻠﻣﺑﻧﻰ ﺍﻟﺭﺋﻳﺳﻲ ﻓﻘﻁ ﻭﻻ‬ ‫•‬
‫ﻳﺟﻭﺯ ﺍﺳﺗﻌﻣﺎﻟﻬﺎ ﺑﺷﻛﻝ ﻣﻧﻔﺻﻝ ﺃﻭ ﻟﻸﻏﺭﺍﺽ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻛﻣﺎ ﻳﺻﺭﺡ‬
‫ﺑﺎﺳﺗﻌﻣﺎﻝ ﺃﺳﻁﺢ ﺍﻟﻣﻼﺣﻖ ﻟﻭﺿﻊ ﺧﺯﺍﻧﺎﺕ ﺍﻟﻣﻳﺎﻩ ﻭﺃﺟﻬﺯﺓ ﺍﻟﺗﻛﻳﻳﻑ‬
‫ﻓﻘﻁ ﺩﻭﻥ ﺃﻱ ﺍﻏﺭﺍﺽ ﺃﺧﺭﻯ ﻭﻻ ﻳﺻﺭﺡ ﺑﻌﻣﻝ ﺳﻼﻟﻡ ﺭﺋﻳﺳﻳﺔ ﺗﺅﺩﻱ‬
‫ﺇﻟﻰ ﺳﻁﺢ ﺍﻟﻣﻼﺣﻖ ﺍﻟﻣﻼﺻﻘﺔ ﻟﻠﺟﺎﺭ‪.‬‬
‫ﺍﺳﺗﻌﻣﺎﻻﺕ ﺍﻟﻣﺑﺎﻧﻲ‪:‬‬ ‫•‬

‫ﻓﻲ ﺍﻟﻣﻧﺎﻁﻖ ﺍﻟﺻﻧﺎﻋﻳﺔ ﺍﻟﺟﺩﻳﺩﺓ ﻳﺳﻣﺢ ﺑﺎﺳﺗﻌﻣﺎﻝ ﺍﻟﺟﺯء ﺍﻷﻣﺎﻣﻲ‬ ‫•‬


‫ﺍﻟﻣﻁﻝ ﻋﻠﻰ ﺍﻟﺷﺎﺭﻉ ﺍﻟﺭﺋﻳﺳﻲ ﻛﻣﺣﻼﺕ ﺃﻭ ﺍﻟﻣﻌﺎﺭﺽ ﺑﺎﻟﻁﺎﺑﻖ‬
‫ﺍﻷﺭﺿﻲ ﻛﺫﻟﻙ ﻛﻣﻛﺎﺗﺏ ﻭﻣﺎ ﺇﻟﻰ ﺫﻟﻙ ﺑﺎﻟﻁﻭﺍﺑﻖ ﺍﻟﻌﻠﻭﻳﺔ ﻋﻠﻰ ﺃﻥ ﻻ‬
‫ﻳﻘﻝ ﻋﻣﻖ ﻫﺫﺍ ﺍﻟﺟﺯء ﻋﻥ ﻋﺷﺭﻭﻥ ﻣﺗﺭﺍ ﻭﻓﻲ ﻫﺫﻩ ﺍﻟﺣﺎﻟﺔ‬
‫ﺗﺳﺗﺛﻧﻲ ﺍﻟﻘﻁﻌﺔ ﻣﻥ ﺷﺭﻁ ﺍﻹﺭﺗﺩﺍﺩ ﺍﻻﻣﺎﻣﻲ‪.‬‬
‫ﻳﺳﻣﺢ ﺑﺈﻗﺎﻣﺔ ﺳﻛﻥ ﻟﻠﻌﻣﺎﻝ ﺑﺩﺍﺧﻝ ﻗﻁﻊ ﺍﻷﺭﺍﺿﻲ ﺍﻟﺻﻧﺎﻋﻳﺔ ﻁﺎﺑﻖ‬ ‫•‬
‫ﺃﺭﺿﻲ ﻭﺍﺣﺩ ﻓﻲ ﺣﺩﻭﺩ ﺍﻟﻣﻌﻘﻭﻝ ﻭﺣﺳﺏ ﻧﻭﻉ ﺍﻟﺻﻧﺎﻋﺔ ﺍﻟﻣﻘﺎﻣﺔ‬
‫ﺑﺩﺍﺧﻝ ﺍﻟﻘﻁﻌﺔ ﺑﻧﺳﺑﺔ ﻻﺗﺯﻳﺩ ﻋﻥ ‪ 30%‬ﻣﻥ ﺍﻟﻣﺳﺎﺣﺔ ﺍﻟﻣﺧﺻﺻﺔ‬
‫ﻟﻠﺑﻧﺎء )ﺍﻟﻣﺳﺎﺣﺔ ﺍﻟﺻﺎﻓﻳﺔ ﺑﻌﺩ ﺧﺻﻡ ﻣﺳﺎﺣﺔ ﺍﻻﺭﺗﺩﺍﺩﺕ(‪.‬‬

‫ﺍﻟﻧﻭﺍﻓﺫ ﻭﺍﻷﺑﻭﺍﺏ‬
‫‪:‬‬ ‫•‬
‫ﺗﺯﻭﺩ ﻛﻝ ﻏﺭﻓﺔ ﺃﻭ ﻣﺭﻓﻖ ﻣﻥ ﻣﺭﺍﻓﻖ ﺍﻟﺑﻧﺎء ﺑﻔﺗﺣﺔ ﺃﻭ ﻋﺩﺓ ﻓﺗﺣﺎﺕ‬ ‫•‬
‫)ﻧﻭﺍﻓﺫ( ﻟﻠﺗﻬﻭﻳﺔ ﻭﺍﻹﺿﺎءﺓ ﺍﻟﻁﺑﻳﻌﻳﺔ ﺗﻁﻝ ﻋﻠﻰ ﺍﻟﺷﺎﺭﻉ ﺃﻭ ﻁﺭﻳﻖ‬
‫ﺃﻭ ﻓﻧﺎء ﺩﺍﺧﻠﻲ ﻭﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺃﻥ ﻳﻛﻭﻥ ﻣﺳﻁﺢ ﺗﻠﻙ ﺍﻟﻔﺗﺣﺔ ﺑﺣﺩ‬
‫ﺃﺩﻧﻰ ﻳﻠﻲ‪:‬‬
‫• )‪(7%‬ﻣﻥ ﻣﺳﻁﺢ ﺃﺭﺿﻳﺔ ﺍﻟﻐﺭﻑ ﺍﻟﺳﻛﻧﻳﺔ ﺃﻭ ﺍﻟﻣﻛﺎﺗﺏ‪.‬‬
‫• )‪(5%‬ﻣﻥ ﻣﺳﻁﺢ ﺃﺭﺿﻳﺔ ﺍﻟﺣﻣﺎﻣﺎﺕ ﻭﺍﻟﻣﺭﺍﺣﻳﺽ‪.‬‬
‫• )‪(6%‬ﻣﻥ ﻣﺳﻁﺢ ﺃﺭﺿﻳﺔ ﺍﻟﻣﻁﺑﺦ ﺃﻭ ﺑﺋﺭ ﺍﻟﺳﻠﻡ‪.‬‬
‫ﻳﺟﺏ ﺃﻻ ﻳﻘﻝ ﻋﺭﺽ ﺑﺎﺏ ﻣﺩﺧﻝ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺳﻛﻧﻳﺔ ﻋﻥ ‪ 1‬ﻣﺗﺭ ﻭﺑﺎﺏ‬ ‫•‬
‫ﻏﺭﻑ ﺍﻟﻧﻭﻡ ﻋﻥ ‪ 90‬ﺳﻡ ﻭﺑﺎﺏ ﺍﻟﻣﻁﺑﺦ ﻋﻥ ‪ 80‬ﺳﻡ ﻭﺑﺎﺏ ﺍﻟﺣﻣﺎﻡ‬
‫ﻭﻣﺎﻓﻲ ﺣﻛﻣﺔ ﻋﻥ ‪ 75‬ﺳﻡ ‪،‬ﻛﻣﺎ ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﺍﺭﺗﻔﺎﻉ ﺍﻟﺑﺎﺏ ﻋﻥ‬
‫‪2.10‬ﻣﻥ ﻣﻘﺎﺳﺎ ﻣﻥ ﻣﻧﺳﻭﺏ ﺳﻁﺢ ﺍﻷﺭﺿﻳﺔ ﺣﺗﻰ ﺑﻁﻧﻳﻪ ﺍﻟﻌﺗﺏ ‪.‬‬
‫ﺍﻷﺭﻭﻗﺔ)ﺍﻟﻠﻳﻭﺍﻥ‬
‫(‬ ‫•‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻛﻭﻥ ﺍﻟﻣﺑﻧﻰ ﻣﻁﻼ ﻋﻠﻰ ﺍﻟﺷﺎﺭﻉ ﻭﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺭﻭﺍﻕ )ﺑﻭﺍﻛﻲ(ﺃﻭ ﻣﺎ‬
‫ﻳﺳﻣﻰ ﻟﻳﻭﺍﻥ ﻓﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺗﺎﻟﻲ‪:-‬‬
‫• ﺃﺧﺫ ﻣﻭﺍﻓﻘﺔ ﺩﺍﺋﺭﺓ ﺍﻟﺑﻠﺩﻳﺔ ﻋﻠﻰ ﺍﻟﺗﺻﻣﻳﻡ ﻭﻁﺭﺍﺯ ﻫﺫﻩ ﺍﻟﺑﻭﺍﻛﻲ‪.‬‬
‫• ﻳﻣﻛﻥ ﻋﻣﻝ ﺑﺭﻭﺯﺍﺕ ﺟﻣﺎﻟﻳﺔ ﻭﺯﺧﺭﻓﻳﺔ ﻓﻲ ﺍﻟﺑﻭﺍﻛﻲ ﺑﻣﻘﺩﺍﺭ ﻻﻳﺯﻳﺩ ﻋﻥ‬
‫)‪45‬ﺳﻡ( ﻭﻳﺷﺗﺭﻁ ﺃﻥ ﻻﻳﻘﻝ ﺍﻻﺭﺗﻔﺎﻉ ﻋﻥ)‪ 280‬ﺳﻡ( ﻣﻥ ﺃﺭﺿﻳﺔ‬
‫ﺍﻟﺭﻭﺍﻕ‪.‬‬
‫• ﺃﻥ ﻳﻛﻭﻥ ﺑﺭﻭﺯ ﺃﻛﺗﺎﻑ ﺍﻷﻋﻣﺩﺓ ﺑﻣﺎ ﻻﻳﺯﻳﺩ ﻋﻥ)‪ 15‬ﺳﻡ( ‪.‬‬
‫• ﻳﺗﻡ ﺗﻭﻓﻳﺭ ﻣﻛﺎﻥ ﺧﺎﺹ ﺑﺎﻟﻠﻭﺣﺎﺕ ﺍﻹﻋﻼﻧﻳﺔ ﻓﻲ ﺗﺻﻣﻳﻡ ﺍﻟﺭﻭﺍﻕ ﺁﺧﺫﺍ ﻓﻲ‬
‫ﺍﻹﻋﺗﺑﺎﺭ ﺍﻟﺯﺧﺎﺭﻑ ﺇﻥ ﻭﺟﺩﺕ‪.‬‬
‫• ﺃﻥ ﺗﻛﻭﻥ ﻓﺗﺣﺎﺕ ﺍﻟﺭﻭﺍﻕ ﻭﺍﻟﺑﻭﺍﻛﻲ ﻣﺗﻧﺎﺳﻘﺔ ﻭﻣﺗﺳﺎﻭﻳﺔ ﻓﻲ ﺍﻷﻁﻭﺍﻝ‬
‫ﻭﺍﻹﺭﺗﻔﺎﻋﺎﺕ ﻣﻧﺗﻅﻣﺔ‪.‬‬
‫• ﺃﻥ ﻻ ﻳﺗﻡ ﻭﺿﻊ ﻋﻭﺍﺋﻖ ﺃﻭ ﺍﺷﻐﺎﻻﺕ ﺗﻌﻳﻖ ﺣﺭﻛﺔ ﺍﻟﻣﺷﺎﺓ ﻓﻳﻪ‪.‬‬
‫• ﻣﺭﺍﻋﺎﺓ ﺩﺭﺍﺳﺔ ﻣﻧﺳﻭﺏ ﺍﻟﺭﻭﺍﻕ ﻣﻊ ﺍﻷﺭﻭﻗﺔ ﺍﻟﻣﺟﺎﻭﺭﺓ ﺣﺗﻰ ﺗﺳﻬﻝ‬
‫ﻋﻣﻠﻳﺔ ﺍﻟﻣﺭﻭﺭ ﻣﻥ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﻣﺟﺎﻭﺭﺓ ﺇﻟﻰ ﺍﻟﻣﺑﻧﻰ ﺍﻟﺟﺩﻳﺩ‪.‬‬
‫‪:‬‬‫ﺇﺭﺗﻔﺎﻋﺎﺕ ﺍﻟﻣﺑﺎﻧﻲ‬ ‫•‬
‫ﻳﺣﺩﺩ ﺃﻗﺻﻰ ﺇﺭﺗﻔﺎﻉ ﻟﻠﺑﻧﺎء ﻣﺳﻣﻭﺡ ﺑﻪ ﺣﺳﺏ ﺷﺭﻭﻁ ﻛﻝ ﻣﻧﻁﻘﺔ ﻭﻓﻘﺎ‬
‫ﻟﻠﻣﺧﻁﻁﺎﺕ ﺍﻟﺗﻔﺻﻳﻠﻳﺔ ﻟﻬﺎ ﺍﻟﺻﺎﺩﺭﺓ ﻣﻥ ﺩﺍﺋﺭﺓ ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ‬
‫ﻭﻳﻛﻭﻥ ﻣﺣﻭﺭ ﺍﻟﻁﺭﻳﻖ ﺍﻟﻌﺎﻡ ﺍﻟﻣﺟﺎﻭﺭ ﻫﻭ ﺍﻟﻣﻣﻧﺳﻭﺏ ﺍﻟﺫﻱ ﻳﻘﺎﺱ‬
‫ﻣﻧﻪ ﺍﻹﺭﺗﻔﺎﻉ ﻭﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﻭﻗﻭﻉ ﺍﻟﺑﻧﺎء ﻋﻠﻰ ﻁﺭﻳﻖ ﻋﺎﻡ ﻳﻘﺎﺱ‬
‫ﺍﻹﺭﺗﻔﺎﻉ ﻣﻥ ﻣﻧﺳﻭﺏ ﺍﻟﺻﻔﺭ ﺍﻟﻣﺳﺎﺣﻲ ﻟﻠﻣﻧﻁﻘﺔ ﻭﺍﻟﻣﺣﺩﺩ ﻣﻥ ﺩﺍﺋﺭﺓ‬
‫ﺍﻟﺗﺧﻁﻳﻁ ﻭﺍﻟﻣﺳﺎﺣﺔ‪.‬‬
‫ﺍﻹﺭﺗﻔﺎﻋﺎﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ‪:‬‬ ‫•‬

‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﻣﻧﺎﻁﻖ ﺍﻟﺳﻛﻧﻳﺔ ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻭﺍﻷﻗﺻﻰ ﻟﺻﺎﻓﻲ‬ ‫•‬


‫ﺍﻹﺭﺗﻔﺎﻉ ﺍﻟﺩﺍﺧﻠﻲ ﻋﻠﻰ ﺍﻟﻧﺣﻭ ﺍﻟﺗﺎﻟﻲ‪:-‬‬
‫ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﺃﻭ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﻣﺳﺩﻳﺔ ﻣﻥ ﺍﻟﻁﺎﺑﻖ ﻭﺍﺣﺩ ﺑﺣﺩ ﺃﺩﻧﻰ‬ ‫•‬
‫‪3‬ﺃﻣﺗﺎﺭ ﻭﺑﺣﺩ ﺃﻗﺻﻰ ‪ 4‬ﺃﻣﺗﺎﺭ‪.‬‬
‫ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻌﻠﻭﻳﺔ ‪ :‬ﺑﺣﺩ ﺃﺩﻧﻰ ‪ 2.80‬ﻭﺑﺣﺩ ﺃﻗﺻﻰ ‪ 3.60‬ﻣﺗﺭﺍ ‪.‬‬ ‫•‬
‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﻣﺑﺎﻧﻲ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻭﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺑﻳﻥ‬ ‫•‬
‫ﺍﻷﺩﻧﻰ ﻭﺍﻷﻗﺻﻰ ﻟﺻﺎﻓﻲ ﺍﻹﺭﺗﻔﺎﻉ ﺍﻟﺩﺍﺧﻠﻲ ﻋﻠﻰ ﺍﻟﻧﺣﻭ ﺍﻟﺗﺎﻟﻲ‪:-‬‬
‫• ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﻁﺎﺑﻖ ﻣﻳﺯﺍﻧﻳﻥ ﺑﺣﺩ ﺃﺩﻧﻰ ‪4‬‬
‫ﺃﻣﺗﺎﺭ ﻭﺑﺣﺩ ﺃﻗﺻﻰ ‪ 4.75‬ﻣﺗﺭﺍ ﺳﻭﺍء ﻛﺎﻥ ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ‬
‫ﺿﻣﻥ ﻣﺑﻧﻰ ﻣﺗﻌﺩﺩ ﺍﻟﻁﻭﺍﺑﻖ ﺃﻭ ﻣﺑﻧﻰ ﺗﺟﺎﺭﻱ ﺫﻭ ﻁﺎﺑﻖ ﻭﺍﺣﺩ‪.‬‬
‫• ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺳﺩﻩ ﺗﺟﺎﺭﻳﺔ ﺳﻭﺍء ﻛﺎﻥ‬
‫ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﺿﻣﻥ ﻣﺑﻧﻰ ﺳﻛﻧﻲ ﺗﺟﺎﺭﻱ ﻣﺗﻌﺩﺩ ﺍﻟﻁﻭﺍﺑﻖ ﺃﻭ‬
‫ﻣﺑﻧﻰ ﺗﺟﺎﺭﻱ ﺫﻭ ﻁﺎﺑﻖ ﻭﺍﺣﺩ ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻟﻺﺭﺗﻔﺎﻉ ‪6‬‬
‫ﺃﻣﺗﺎﺭ ﻭﻳﻣﻛﻥ ﺍﻟﺗﺟﺎﻭﺯ ﺑﻣﻘﺩﺍﺭ ‪ 70‬ﺳﻡ ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺟﺳﺭ‬
‫ﻣﺳﻠﺢ ﻣﺗﺩﻟﻲ ﻣﻥ ﺍﻟﺳﻘﻑ‪.‬‬
‫• ﺍﻟﺳﺩﺓ ﺍﻟﺗﺟﺎﺭﻳﺔ ‪ :‬ﺑﺣﺩ ﺃﺩﻧﻰ ‪ 2.60‬ﻣﺗﺭ ﻭﺑﺣﺩ ﺃﻗﺻﻰ ‪ 3‬ﺃﻣﺗﺎﺭ‪.‬‬
‫• ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻌﻠﻭﻳﺔ ‪ :‬ﺑﺣﺩ ﺃﺩﻧﻰ ‪ 3.00‬ﻣﺗﺭ ﺑﺟﺩ ﺃﻗﺻﻰ ﻣﺗﺭ ﻭﻳﻘﺎﺱ‬
‫ﺍﻹﺭﺗﻔﺎﻉ ﺍﻟﺩﺍﺧﻠﻲ ﻣﻥ ﻣﻧﺳﻭﺏ ﺍﻟﻣﺳﻁﺢ ﺍﻟﻧﻬﺎﺋﻲ ﻟﻸﺭﺿﻳﺔ‬
‫ﺣﺗﻰ ﺑﻁﻳﻧﺔ ﺍﻟﺳﻘﻑ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺗﺧﺻﻳﺹ ﻁﺎﺑﻖ ﻛﻣﻭﻗﻑ ﻟﻠﺳﻳﺎﺭﺍﺕ ﻳﺣﺩﺩ ﺍﺭﺗﻔﺎﻋﻪ ﺍﻟﺻﺎﻓﻲ ‪ 2.5‬ﻣﺗﺭ‪.‬‬
‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﻣﻧﺎﻁﻖ ﺍﻟﺻﻧﺎﻋﻳﺔ ﺗﺗﺣﺩﺩ ﺍﻹﺭﺗﻔﺎﻋﺎﺕ ﻋﻠﻰ ﺍﻟﻧﺣﻭ ﺍﻟﺗﺎﻟﻲ‪:‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﻭﺭﺵ ﻭﺍﻟﻣﺧﺎﺯﻥ ﻭﺍﻟﻣﺻﺎﻧﻊ ﺫﺍﺕ ﺍﻟﺟﻣﺎﻟﻭﻧﺎﺕ )ﺷﺑﺭﺍﺕ(ﻳﻛﻭﻥ‬ ‫•‬
‫ﺍﻹﺭﺗﻔﺎﻉ ‪ 8‬ﺃﻣﺗﺎﺭ ﺑﺣﺩ ﺃﻗﺻﻰ ﺣﺗﻰ ﻗﻣﺔ ﺍﻟﺟﻣﺎﻟﻭﻥ ﻭﻳﻣﻛﻥ ﺗﺟﺎﻭﺯ ﻫﺫﺍ‬
‫ﺍﻹﺭﺗﻔﺎﻉ ﻓﻲ ﺑﻌﺽ ﺍﻟﺻﻧﺎﻋﺎﺕ ﺍﻟﺛﻘﻳﻠﺔ ﺫﺍﺕ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺧﺎﺻﺔ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﻭﺭﺵ ﻭﺍﻟﻣﺧﺎﺯﻥ ﺍﻟﻣﺷﻳﺩﺓ ﺑﺎﻟﻣﻭﺍﺩ ﺍﻟﺛﺎﺑﺗﺔ ﻭﺑﺩﻭﻥ ﺳﺩﻩ‬ ‫•‬
‫ﺗﺟﺎﺭﻳﺔ ﻳﻛﻭﻥ ﺍﻹﺭﺗﻔﺎﻉ ﺑﺣﺩ ﺃﺩﻧﻰ ‪ 4.5‬ﻣﺗﺭ ﻭﺑﺣﺩ ﺃﻗﺻﻰ ‪ 6‬ﺃﻣﺗﺎﺭ ﺃﻣﺎ ﻓﻲ‬
‫ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺳﺩﻩ ﺗﺟﺎﺭﻳﺔ ﻓﻳﻛﻭﻥ ﺍﻹﺭﺗﻔﺎﻉ ﺑﺣﺩ ﺍﻷﺩﻧﻰ ‪ 6‬ﺃﻣﺗﺎﺭ ﻭﺑﺣﺩ‬
‫ﺃﻗﺻﻰ ‪7‬ﺃﻣﺗﺎﺭ ﻭﻳﻣﻛﻥ ﺗﺟﺎﻭﺯ ﻫﺫﺍ ﺍﻹﺭﺗﻔﺎﻉ ﻓﻲ ﺑﻌﺽ ﺣﺎﻻﺕ ﺍﻟﺻﻧﺎﻋﺎﺕ‬
‫ﺍﻟﺛﻘﻳﻠﺔ‪.‬‬
‫ﺇﺫﺍ ﺍﻗﺗﺿﻰ ﺍﻟﺗﺻﻣﻳﻡ ﺍﻟﺩﺍﺧﻠﻲ ﺍﻹﻧﺷﺎﺋﻲ ﻟﻠﺑﻧﺎء ﺗﺩﻟﻰ ﺟﺳﺭ ﻣﺳﻠﺢ ﻣﻥ‬ ‫•‬
‫ﺍﻟﻬﻳﻛﻝ ﺍﻹﻧﺷﺎﺋﻲ ﻟﻠﺳﻘﻑ ﺩﺍﺧﻝ ﺍﻟﻐﺭﻑ ﺃﻭ ﺍﻟﻣﻛﺗﺏ ﺃﻭ ﺍﻟﺩﻛﺎﻥ ﻓﻼ ﻳﺟﻭﺯ ﺃﻥ‬
‫ﻳﺯﻳﺩ ﻫﺫﺍ ﺍﻟﺟﺯء ﺍﻟﻣﺗﺩﻟﻰ ﻋﻥ ‪ 40‬ﺳﻡ ﻓﻲ ﺣﺎﻟﺔ ﺗﻁﺑﻳﻖ ﺍﻷﺩﻧﻰ ﻹﺭﺗﻔﺎﻉ‬
‫ﺍﻟﻁﺎﺑﻖ‪.‬‬
‫ﻓﻣﻳﺎ ﻳﺗﻌﻠﻖ ﺑﺈﺭﺗﻔﺎﻋﺎﺕ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﻌﺎﻣﺔ ﻣﺛﻝ ﺍﻟﻣﺩﺍﺭﺱ ﻭﺍﻟﻣﺳﺗﺷﻔﻳﺎﺕ‬ ‫•‬
‫ﻭﺍﻟﻣﻌﺎﺭﺽ ﺍﻟﺩﻭﻟﻳﺔ ﻭﻗﺎﻋﺎﺕ ﺍﻟﺳﻳﻧﻣﺎ ﻭﻣﺎﻓﻲ ﺣﻛﻣﻬﺎ ﺗﻁﺑﻖ ﺍﻟﻣﻌﺎﻳﻳﺭ‬
‫ﺍﻟﺩﻭﻟﻳﺔ ﻟﻺﺭﺗﻔﺎﻋﺎﺕ‪.‬‬
‫ﻣﻧﺎﺳﻳﺏ ﺍﻟﺑﻧﺎء‬ ‫•‬
‫ﻳﺣﺩﺩ ﺍﻟﻣﻧﺳﻭﺏ ﺍﻟﻣﺭﺟﻌﻲ ﻋﻠﻰ ﺍﻻﺭﺗﻔﺎﻉ ) ‪30‬ﺳﻡ ( ﻣﻥ ﻣﺣﻭﺭ ﺍﻟﻁﺭﻳﻖ‬ ‫•‬
‫ﺍﻟﻣﻘﺎﻡ ﻋﻠﻳﻪ ﻗﻁﻌﺔ ﺍﻷﺭﺽ ﻭﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﻣﻳﻭﻝ ﻁﻭﻟﻳﺔ ﻓﻲ ﺍﻟﻁﺭﻳﻖ‬
‫ﻳﺭﺍﻋﻲ ﻋﻣﻝ ﺍﻟﺗﺩﺭﺝ ﺍﻟﻣﻁﻠﻭﺏ ﻓﻲ ﻣﻧﺳﻭﺏ ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﺑﻣﺎ ﻳﺿﻣﻥ‬
‫ﺍﻟﺣﻔﺎﻅ ﻋﻠﻰ ﺍﻟﻣﻧﺳﻭﺏ ﺍﻟﻣﺭﺟﻌﻲ ﺍﻟﻣﻁﻠﻭﺏ‪.‬‬
‫ﻻﻳﺟﺏ ﺃﻥ ﻳﺯﻳﺩ ﻣﻧﺳﻭﺏ ﺍﻟﺗﺷﻁﻳﺏ ﻟﻠﺩﻭﺭ ﺍﻷﺭﺿﻲ ﻋﻥ ) ‪120‬ﺳﻡ ( ﻣﻥ‬ ‫•‬
‫ﻣﻧﺳﻭﺏ ﺣﺎﻓﺔ ﺍﻟﻁﺭﻳﻖ ﺑﺈﺳﺗﺛﻧﺎء ﺍﻟﻔﻠﻝ ﺍﻟﺳﻛﻧﻳﺔ ﻓﻼ ﻳﺟﺏ ﺃﻥ ﻳﺯﻳﺩ ﻋﻥ‬
‫)‪150‬ﺳﻡ (‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺷﺎﺭﻋﻳﻥ ﺃﻭ ﺃﻛﺛﺭ ﻓﻼ ﻳﺟﺏ ﺃﻥ ﻳﺯﻳﺩ ﻣﻧﺳﻭﺏ ﺍﻟﺗﺷﻁﻳﺏ‬ ‫•‬
‫ﻟﻠﺩﻭﺭ ﺍﻷﺭﺿﻲ ﻋﻥ)‪45‬ﺳﻡ(ﻣﻥ ﻣﻧﺳﻭﺏ ﺣﺎﻓﺔ ﺍﻟﻁﺭﻳﻖ ﺍﻟﻣﺭﺗﻔﻊ ﺃﻭ ) ‪120‬‬
‫ﺳﻡ ( ﻣﻥ ﺣﺎﻓﺔ ﺍﻟﻁﺭﻳﻖ ﺍﻟﻣﻧﺧﻔﺽ ﻭﻋﻥ )‪ 150‬ﺳﻡ ( ﻟﻠﻔﻳﻼﺕ ﺍﻟﺳﻛﻧﻳﺔ‬
‫ﻣﻥ ﺍﻟﺷﺎﺭﻉ ﺍﻟﺫﻱ ﻳﻁﻝ ﻋﻠﻳﻪ ﻣﺩﺧﻠﻬﺎ ﺍﻟﺭﺋﻳﺳﻲ‪.‬‬
‫ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﺇﺭﺗﻔﺎﻉ ﺍﻷﺳﻭﺍﺭ ﻭﺍﻟﺣﻭﺍﺋﻁ ﺍﻟﻔﺎﺻﻠﺔ ﺍﻟﻣﻘﺎﻣﺔ ﺑﻳﻥ ﻗﻁﻊ‬ ‫•‬
‫ﺍﻷﺭﺍﺿﻲ ﺍﻟﻣﺟﺎﻭﺭﺓ ﻋﻥ ‪ 2.10‬ﻭﻻﻳﺯﻳﺩ ﻋﻥ )‪ 3‬ﻡ( ﺑﻣﺎ ﻓﻲ ﺫﻟﻙ ﺃﻱ‬
‫ﺯﺧﺎﻑ ﻗﺩ ﺗﻌﻠﻭ ﺍﻟﺳﻭﺭ‪.‬‬
‫ﻁﺎﺑﻖ ﺍﻟﺳﻁﺢ‬ ‫•‬
‫ﻳﺻﺭﺡ ﺑﺈﺿﺎﻓﺔ ﻁﺎﺑﻖ ﺍﻟﺳﻁﺢ ﻓﻭﻕ ﺍﻟﻁﺎﺑﻖ ﺍﻷﺧﻳﺭ ﻓﻲ ﺟﻣﻳﻊ ﺍﻟﻣﺑﺎﻧﻲ‬ ‫•‬
‫ﻭﺫﻟﻙ ﺑﺈﺳﺗﺛﻧﺎء ﺍﻟﻔﻠﻝ ﺍﻟﺳﻛﻧﻳﺔ ﻭﺍﻟﻣﺑﺎﻧﻲ ﻭﺍﻟﻣﻧﺷﺂﺕ ﺍﻟﺻﻧﺎﻋﻳﺔ ﻭﺳﻛﻥ‬
‫ﺍﻟﻌﻣﺎﻝ‪.‬‬
‫ﻳﺧﺻﺹ ﻁﺎﺑﻖ ﺍﻟﺳﻁﺢ ﻟﺑﻧﺎء ﻏﺭﻑ ﺃﺟﻬﺯﺓ ﺍﻟﻣﺻﺎﻋﺩ ﻭﺧﺯﺍﻧﺎﺕ ﺍﻟﻣﻳﺎﻩ‬ ‫•‬
‫ﻭﻏﺭﻑ ﺍﻟﻣﺿﺧﺎﺕ ﻭﺍﻟﻛﻬﺭﺑﺎء ﻭﺍﻟﻬﻭﺍﺗﻑ ﻭﺑﻌﺽ ﺍﻟﻣﻅﻼﺕ ﺍﻟﺗﺟﻣﻳﻠﻳﺔ‬
‫)ﺑﺭﺟﻭﻻﺕ( ﻭﺣﻣﺎﻣﺎﺕ ﺍﻟﺳﺑﺎﺣﺔ ﻛﻣﺎ ﻳﺳﻣﺢ ﺑﺈﻧﺷﺎء ﺻﺎﻻﺕ ﺍﻟﺗﺩﺭﻳﺑﺎﺕ‬
‫ﺍﻟﺭﻳﺎﺿﻳﺔ)ﺟﻣﻧﺎﺯﻳﻭ( ﻭﺍﻟﺧﺩﻣﺎﺕ ﺍﻟﺗﺎﺑﻌﺔ ﻟﻬﺎ ﻟﺧﺩﻣﺔ ﺳﻛﺎﻥ ﺍﻟﻣﺑﻧﻰ ﻓﻘﻁ‬
‫ﺇﺫﺍ ﺯﺍﺩﺕ ﻣﺳﺎﺣﺔ ﺍﻷﺭﺽ ﻋﻥ)‪230‬ﻡ (‪.‬‬
‫‪2‬‬

‫ﻳﺟﺏ ﺃﻥ ﻻ ﺗﺯﻳﺩ ﻣﺳﺎﺣﺔ ﺍﻹﻧﺷﺎءﺍﺕ ﻋﻥ )‪ (10%‬ﻣﻥ ﻣﺳﺎﺣﺔ ﻣﺳﻁﺢ‬ ‫•‬


‫ﺁﺧﺭ ﻁﺎﺑﻖ ﻋﻠﻰ ﺃﻥ ﻻ ﻳﻘﻝ ﺇﺭﺗﺩﺍﺩﻫﺎ ﻋﻥ)‪ 150‬ﺳﻡ( ﻣﻥ ﺣﺩ ﺍﻟﻣﺑﻧﻰ‪.‬‬
‫ﻻ ﻳﺣﺗﺳﺏ ﺣﻭﺽ ﺍﻟﺳﺑﺎﺣﺔ ﺿﻣﻥ ﺍﻟﻣﺳﺎﺣﺔ ﺍﻟﻣﺑﻧﻳﺔ‪.‬‬ ‫•‬
‫ﻳﺭﺍﻋﻲ ﺃﻥ ﻻﻳﺯﻳﺩ ﺇﺭﺗﻔﺎﻉ ﺣﻭﺽ ﺍﻟﺳﺑﺎﺣﺔ ﻋﻥ )‪ 240‬ﺳﻡ ( ﻣﻥ ﻣﻧﺳﻭﺏ‬ ‫•‬
‫ﺍﻟﺳﻁﺢ ﻭﺃﻥ ﻻﻳﺯﻳﺩ ﺇﺭﺗﻔﺎﻉ ﺻﺎﻟﺔ ﺍﻟﺗﺩﺭﻳﺑﺎﺕ ﺍﻟﺭﻳﺎﺿﻳﺔ ﻋﻥ)‪ 350‬ﺳﻡ(‪.‬‬
‫ﻻ ﻳﺻﺭﺡ ﺑﻭﺿﻊ ﺃﻳﺔ ﺇﻧﺷﺎءﺍﺕ ﻓﻭﻕ ﻣﻧﺳﻭﺏ ﺍﻟﺳﻘﻑ ﻟﻁﺎﺑﻖ ﺍﻟﺳﻁﺢ ﺃﻭ‬ ‫•‬
‫ﻣﻧﺳﻭﺏ ﺣﻭﺽ ﺍﻟﺳﺑﺎﺣﺔ ﻭﻳﺳﺗﺛﻧﻰ ﻣﻥ ﺫﻟﻙ ﻏﺭﻓﺔ ﺍﻟﻣﺻﻌﺩ ﻭﺍﻟﺳﻠﻡ ﺑﺣﺩﻫﺎ‬
‫ﺍﻷﺩﻧﻰ ﻭﺧﺯﺍﻧﺎﺕ ﺍﻟﻣﻳﺎﻩ ﻭﻣﻌﺩﺍﺕ ﺍﻟﺗﻛﻳﻳﻑ ﺍﻟﻣﺭﻛﺯﻱ‪.‬‬
‫ﻳﺟﺏ ﺗﻐﻁﻳﺔ ﻏﺭﻑ ﺍﻟﺧﺩﻣﺎﺕ ﻭﺍﻟﻣﻌﺩﺍﺕ ﻭﺍﻟﺧﺯﺍﻧﺎﺕ ﻋﻠﻰ ﻁﺎﺑﻖ ﺍﻟﺳﻁﺢ‬ ‫•‬
‫ﻭﺗﻘﺩﻳﻡ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻟﺗﻔﺻﻳﻠﻳﺔ ﺍﻟﺗﻲ ﺗﻭﺿﺢ ﻁﺭﻕ ﺗﻠﻙ ﺍﻟﺗﻐﻁﻳﺔ ﺣﺗﻰ ﻻ‬
‫ﺗﺷﻭﻩ ﺍﻟﻣﻧﻅﺭ ﺍﻟﻌﺎﻡ‪.‬‬
‫ﻳﺻﺭﺡ ﺑﻭﺿﻊ ﺍﻟﻠﻭﺣﺎﺕ ﺍﻹﻋﻼﻧﻳﺔ ﻋﻠﻰ ﻁﺎﺑﻖ ﺍﻟﺳﻁﺢ ﻭﻓﻘﺎ ﻟﻠﺷﺭﻭﻁ‬ ‫•‬
‫ﺍﻟﺧﺎﺻﺔ ﺑﺫﻟﻙ‪.‬‬
‫ﻻ ﻳﺳﻣﺢ ﻹﺳﺗﺧﺩﺍﻡ ﺍﻟﻣﻧﺷﺂﺕ ﺍﻟﻣﻘﺎﻣﺔ ﻋﻠﻰ ﺍﻟﺳﻁﺢ ﻷﻱ ﺃﻏﺭﺍﺽ ﺗﺟﺎﺭﻳﺔ‬ ‫•‬
‫ﺑﺄﻱ ﻭﺳﻳﻠﺔ ﻛﺎﻧﺕ ﻭﻳﻘﺗﺻﺭ ﺇﺳﺗﺧﺩﺍﻣﻬﺎ ﻋﻠﻰ ﺳﻛﺎﻥ ﺍﻟﻣﺑﻧﻰ‪.‬‬
‫ﺍﻟﻣﻧﺎﻭﺭ ﺍﻟﺩﺍﺧﻠﻳﺔ‬ ‫•‬
‫ﻳﺟﻭﺯ ﺃﻥ ﺗﺷﻣﻝ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺳﻛﻧﻳﺔ ﻭﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻣﺗﻌﺩﺩﺓ ﺍﻟﻁﻭﺍﺑﻖ‬ ‫•‬
‫ﻋﻠﻰ ﻣﻧﻭﺭ ﺗﻁﻝ ﻋﻠﻳﻪ ﺍﻟﻣﻁﺎﺑﺦ ﻭﺍﻟﺣﻣﺎﻣﺎﺕ ﻭﺩﻭﺭﺍﺕ ﺍﻟﻣﻳﺎﻩ ﻭﺍﺿﻁﺭﺍﺭﻳﺎ‬
‫ﺑﻌﺽ ﻏﺭﻑ ﺍﻟﻧﻭﻡ ﺃﻭ ﺍﻟﻣﻛﺎﺗﺏ ﻋﻠﻰ ﺃﻥ ﺗﻛﻭﻥ ﻣﺳﺎﺣﺔ ﺃﺑﻌﺎﺩﻩ ﻭﻓﻘﺎ ﻟﻣﺎ ﻫﻭ‬
‫ﻣﻭﺿﺢ ﺑﺎﻟﺟﺩﻭﻝ ﺍﻟﺗﺎﻟﻲ‪:-‬‬
‫ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﺟﺯء ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ‬
‫ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ‬
‫ﺍﻟﻣﻁﻝ ﻣﻥ ﺍﻟﻣﺑﻧﻰ ﻟﻣﺳﺎﺣﺔ ﺍﻟﻣﻧﻭﺭ‬ ‫ﺍﻟﻁﻭﺍﺑﻖ‬ ‫ﻡ‬
‫ﻷﻗﻝ ﺿﻠﻊ )ﻡ(‬
‫ﺑﺎﻟﻣﺗﺭ ﺍﻟﻣﺭﺑﻊ‬ ‫ﻋﻠﻰ ﺍﻟﻣﻧﻭﺭ‬
‫‪12.00‬ﻣﺭﺑﻊ ‪3.00‬‬ ‫• ﻁﺎﺑﻖ ﻭﺍﺣﺩ ﺇﻟﻰ ﻏﺭﻓﺔ ﺳﻛﻧﻳﺔ‬ ‫‪1‬‬
‫‪3.00‬‬ ‫ﺧﻣﺱ‬ ‫ﻭﻣﻛﺎﺗﺏ‬ ‫ﺛﻼﺙ ﻁﻭﺍﺑﻖ‪.‬‬
‫ﺍﻹﺭﺗﻔﺎﻉ ) × ﻉ(‪2‬‬ ‫• ﺃﻛﺛﺭ ﻣﻥ ﺛﻼﺙ ﻏﺭﻓﺔ ﺳﻛﻧﻳﺔ‬
‫ﻭﻣﻛﺎﺗﺏ‬ ‫ﻁﻭﺍﺑﻖ‪.‬‬
‫‪2.50‬‬ ‫ﻣﻥ ﻁﺎﺑﻖ ﻭﺍﺣﺩ ﻣﻁﺎﺑﺦ ﺳﻼﻟﻡ ‪7.50‬‬ ‫‪2‬‬
‫ﺇﻟﻰ ﺛﻼﺛﺔ ﻁﻭﺍﺑﻖ ﺣﻣﺎﻣﺎﺕ‬
‫ﻣﺭﺍﺣﻳﺽ‬
‫‪2.50‬‬ ‫ﺃﻛﺛﺭ ﻣﻥ ﺛﻼﺛﺔ ﻣﻁﺎﺑﺦ ﺳﻼﻟﻡ ‪10.00‬‬ ‫‪3‬‬
‫ﻁﻭﺍﺑﻖ ﺇﻟﻰ ﺳﺗﺔ ﺣﻣﺎﻣﺎﺕ‬
‫ﻣﺭﺍﺣﻳﺽ‬ ‫ﻁﻭﺍﺑﻖ‬
‫‪2.50‬‬ ‫ﺃﻛﺛﺭ ﻣﻥ ﺳﺗﺔ ﻣﻁﺎﺑﺦ ﺳﻼﻟﻡ ‪12.50‬‬ ‫‪4‬‬
‫ﺣﻣﺎﻣﺎﺕ‬ ‫ﻁﻭﺍﺑﻖ‬
‫ﻣﺭﺍﺣﻳﺽ‬
‫ﻳﺷﺗﺭﻁ ﺃﻻ ﺗﺯﻳﺩ ﻋﺩﺩ ﺍﻟﻐﺭﻑ ﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﻣﻁﻠﺔ ﻋﻠﻰ ﺇﻟﻰ ﺍﻟﻣﻧﻭﺭ ﻓﻲ‬ ‫•‬
‫ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺳﻛﻧﻳﺔ ﻋﻥ ﻏﺭﻓﺔ ﻭﺍﺣﺩﺓ ﺑﻛﻝ ﻭﺣﺩﺓ ﺳﻛﻧﻳﺔ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺣﻣﺎﻣﺎﺕ ﺃﻭ ﻣﺭﺍﺣﻳﺽ ﻭﺇﺳﺗﺛﻧﺎءﺍ ﺍﻟﻣﻁﺎﺑﺦ ﺑﺎﻟﻣﺑﺎﻧﻲ‬ ‫•‬
‫ﺍﻟﺳﻛﻧﻳﺔ ﻭﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻣﺗﻌﺩﺩﺓ ﺍﻟﻁﻭﺍﺑﻖ ﻳﺟﻭﺯ ﺍﺳﺗﻌﻣﺎﻝ ﻣﻧﻭﺭ‬
‫ﺻﻐﻳﺭ)‪ (duct‬ﺑﻣﺳﻁﺢ ﻻﻳﻘﻝ ﻋﻥ ‪ 1.2‬ﻣﺗﺭ ﻣﺭﺑﻊ ﺷﺭﻳﻁﺔ ﺗﻭﻓﻳﺭ ﺍﻟﻁﺭﻕ‬
‫ﺍﻟﺻﻧﺎﻋﻳﺔ ﺍﻟﺻﺣﻳﺣﺔ ﻟﻠﺗﻬﻭﻳﺔ ﻭﻁﺭﺩ ﺍﻟﺭﻭﺍﺋﺢ ﺍﻟﻛﺭﻳﻬﺔ‪.‬‬
‫ﻳﺟﺏ ﺗﻐﻁﻳﺔ ﺃﺭﺿﻳﺔ ﺍﻟﻣﻧﻭﺭ ﺑﺎﻟﺧﺭﺳﺎﻧﺔ ﺃﻭ ﺍﻟﺑﻼﻁ ﻭﺗﺄﻣﻳﻥ ﻭﺳﻳﻠﺔ ﻣﻧﺎﺳﺑﺔ‬ ‫•‬
‫ﻟﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ ﺍﻷﻣﻁﺎﺭ ﻣﻥ ﺩﺍﺧﻠﻪ‪.‬‬
‫ﻳﺟﺏ ﺗﺯﻭﻳﺩ ﺍﻟﻣﻧﻭﺭ ﺑﻣﺩﺧﻝ ﻟﺗﺳﻬﻳﻝ ﻋﻣﻠﻳﺔ ﺍﻟﺻﻳﺎﻧﺔ ﻭﺍﻟﻧﻅﺎﻓﺔ‪.‬‬ ‫•‬

‫ﻻﻳﺟﻭﺯ ﺇﻗﺎﻣﺔ ﺃﻳﺔ ﻣﻧﺷﺂﺕ ﻣﻥ ﺷﺄﻧﻬﺎ ﺗﻘﻠﻳﻝ ﻛﻣﻳﺔ ﺍﻟﺿﻭء ﺃﻭ ﺍﻟﺗﻬﻭﻳﺔ ﻓﻲ‬ ‫•‬
‫ﺍﻟﻣﻧﺎﻭﺭ ﺃﻭ ﺇﻧﻘﺎﺹ ﻣﺳﺎﺣﺗﻬﺎ‪.‬‬
‫ﻁﺎﺑﻖ ﺍﻟﺗﺳﻭﻳﺔ‬ ‫•‬
‫ﻳﺳﺗﺛﻧﻲ ﻁﺎﺑﻖ ﺍﻟﺗﺳﻭﻳﺔ ﻣﻥ ﺷﺭﻭﻁ ﺇﺭﺗﻔﺎﻋﺎﺕ ﺍﻟﺑﻧﺎء ﻭﻻ ﻳﺳﻣﺢ ﺑﺄﻛﺛﺭ‬
‫ﻣﻥ ﻁﺎﺑﻖ ﺗﺳﻭﻳﺔ ﻭﺍﺣﺩ ﻛﺫﻟﻙ ﻻ ﻳﺳﻣﺢ ﺑﺈﻏﻼﻗﻪ ﻣﻥ ﺍﻟﻧﺎﺣﻳﺔ ﺍﻷﻣﺎﻣﻳﺔ‬
‫ﻭﺑﺗﻭﺟﺏ ﻋﻣﻝ ﺍﻟﺣﻭﺍﺋﻁ ﺍﻟﺳﺎﻧﺩﺓ ﻟﻪ ﻣﻥ ﺧﺭﺳﺎﻧﺔ ﻣﺳﻠﺣﺔ‪.‬‬
‫(‬ ‫ﺍﻟﻁﺎﺑﻖ ﺍﻟﺳﻔﻠﻲ )ﺍﻟﺳﺭﺩﺍﺏ‬ ‫•‬
‫ﻣﺎ ﻟﻡ ﻳﻛﻥ ﻫﻧﺎﻙ ﻣﺷﺎﻛﻝ ﻫﻧﺩﺳﻳﺔ ﺃﻭ ﻓﻧﻳﺔ ﻳﻣﻛﻥ ﻋﻣﻝ ﻁﺎﺑﻖ ﺳﻔﻠﻲ ﻣﻊ‬ ‫•‬
‫ﻋﺩﻡ ﺟﻭﺍﺯ ﺇﺳﺗﻌﻣﺎﻟﻪ ﻟﻠﺳﻛﻥ ﺣﻳﺙ ﻳﺳﺗﺧﺩﻡ ﻛﻣﻭﺍﻗﻑ ﻟﻠﺳﻳﺎﺭﺍﺕ‬
‫ﻭﺍﻟﺧﺩﻣﺎﺕ‪.‬‬
‫ﻳﺟﺏ ﺃﻻ ﻳﺯﻳﺩ ﺑﺭﻭﺯ ﺍﻟﺳﺭﺩﺍﺏ ﻋﻠﻰ ‪ 1.40‬ﻣﻥ ﻣﻧﺳﻭﺏ ﺍﻟﻔﻧﺎء ﺍﻟﺩﺍﺧﻠﻲ‬ ‫•‬
‫ﻟﻠﻘﻁﻌﺔ ﺃﻭ ﻣﻧﺳﻭﺏ ﺭﺻﻳﻑ ﺍﻟﻁﺭﻳﻖ‪.‬‬
‫ﻳﺟﺏ ﺗﻭﻓﻳﺭ ﺗﻬﻭﻳﺔ ﻁﺑﻳﻌﻳﺔ ﻣﺑﺎﺷﺭﺓ ﺃﻭ ﻏﻳﺭ ﻣﺑﺎﺷﺭﺓ ﻟﻪ‪.‬‬ ‫•‬
‫ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻟﺻﺎﻓﻲ ﺇﺭﺗﻔﺎﻉ ﺍﻟﺳﺭﺩﺍﺏ ‪ 2.75‬ﻣﺗﺭ ﻋﻠﻰ ﺃﻻ ﻳﺯﻳﺩ ﻋﻠﻰ‬ ‫•‬
‫‪3.50‬ﻣﺗﺭ ﻣﻘﻳﺎﺱ ﺍﻹﺭﺗﻔﺎﻉ ﻣﻥ ﻣﺳﺗﻭﻯ ﺃﺭﺿﻳﺔ ﺍﻟﺳﺭﺍﺩﺏ ﺣﺗﻰ‬
‫ﺑﺎﻁﻧﻳﺔ ﺑﻼﻁﺔ ﺍﻟﺳﻘﻑ‪.‬‬
‫ﻳﺟﻭﺯ ﺍﻟﺗﺭﺧﻳﺹ ﺑﻣﺭﺣﺎﺽ ﺍﻟﺳﺭﺩﺍﺏ ﺇﺫﺍ ﻭﻓﺭﺕ ﻟﻬﻣﺎ ﻁﺭﻳﻘﺔ ﺍﻟﺻﺭﻑ‬ ‫•‬
‫ﺍﻟﺻﺣﻳﺣﺔ‪.‬‬
‫ﺗﻁﺑﻖ ﺍﻟﺷﺭﻭﻁ ﺍﻟﺧﺎﺻﺔ ﺑﺎﻹﺭﺗﺩﺍﺩﺕ ﻋﻠﻰ ﻁﺎﺑﻖ ﺍﻟﺳﺭﺩﺍﺏ‪.‬‬ ‫•‬
‫ﺗﺅﺧﺫ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ ﺍﻹﺣﺗﻳﺎﻁﺎﺕ ﺍﻟﺧﺎﺻﺔ ﻟﻣﻧﻊ ﺗﺳﺭﺏ ﺍﻟﻣﻳﺎﻩ ﻣﻥ ﺍﻟﺟﺩﺭﺍﻥ‬ ‫•‬
‫ﻭﺍﻷﺭﺿﻳﺎﺕ ﺑﺎﻟﺳﺭﺩﺍﺏ ﻭﻛﺫﻟﻙ ﻭﺳﺎﺋﻝ ﺗﺻﺭﻳﻑ ﺍﻟﻣﻳﺎﻩ ﻭﻋﻣﻝ‬
‫ﺍﻹﺣﺗﻳﺎﻁﺎﺕ ﺍﻟﻼﺯﻣﺔ ﻟﺣﻣﺎﻳﺔ ﺃﻱ ﻣﺑﺎﻧﻲ ﻣﺟﺎﻭﺭﺓ ﻋﻧﺩ ﺇﻧﺷﺎء ﺍﻟﺳﺭﺩﺍﺏ‪.‬‬
‫ﺗﻁﺑﻖ ﺟﻣﻳﻊ ﺍﻹﺷﺗﺭﺍﻁﺎﺕ ﻭﺍﻷﺣﻛﺎﻡ ﺍﻟﺧﺎﺻﺔ ﺑﻭﺳﺎﺋﻝ ﺍﻟﻭﻗﺎﻳﺔ ﻣﻥ ﺍﻟﺣﺭﻳﻖ‬ ‫•‬
‫ﻭﺷﺭﻭﻁ ﺍﻟﺳﻼﻣﺔ ﺍﻟﻌﺎﻣﺔ ﻋﻠﻰ ﺍﻟﻁﺎﺑﻖ ﺍﻟﺳﻔﻠﻲ‪.‬‬
‫ﻳﺣﺏ ﺃﻻ ﺗﺯﻳﺩ ﻣﺳﺎﺣﺔ ﺍﻟﺳﺭﺩﺍﺏ ﻋﻠﻰ ﻣﺳﺎﺣﺔ ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ‪.‬‬ ‫•‬

‫ﺍﻟﻁﺎﺑﻖ ﺍﻟﺩﺍﺧﻠﻲ )ﺍﻟﻣﻳﺯﺍﻧﻳﻥ‬


‫(‬ ‫•‬
‫ﺃﻭﻻ ◌ً ‪-‬ﻳﺭﺧﺹ ﺑﺈﻧﺷﺎء ﺍﻟﻁﺎﺑﻖ ﺍﻟﺩﺍﺧﻠﻲ )ﺍﻟﺳﺩﺓ ﺍﻟﺗﺟﺎﺭﻳﺔ( ﺑﺎﻟﻣﻌﺎﺭﺽ ﻭﺍﻟﻣﺣﻼﺕ‬
‫ﺍﻟﺗﺟﺎﺭﻳﺔ ﻭﻓﻘﺎ ﻟﻠﺷﺭﻭﻁ ﺍﻟﺗﺎﻟﻳﺔ‪:-‬‬
‫• ﺃﻻ ﺗﺯﻳﺩ ﻣﺳﺎﺣﺔ ﺍﻟﺳﺩﺓ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻋﻥ ‪ 50%‬ﻣﻥ ﻣﺳﺎﺣﺔ ﺍﻟﻣﻌﺭﺽ ﺃﻭ‬
‫ﺍﻟﺩﻛﺎﻥ ﻭﻟﻠﺑﻠﺩﻳﺔ ﻋﺩﻡ ﺍﻟﺗﻘﻳﺩ ﺑﺗﻠﻙ ﺍﻟﻧﺳﺑﺔ ﺷﺭﻳﻁﺔ ﺍﻹﻟﺗﺯﺍﻡ ﺑﺗﻭﻓﻳﺭ ﻗﻭﺍﻋﺩ‬
‫ﺍﻟﺳﻼﻣﺔ ﺍﻟﻌﺎﻣﺔ ﻭﺍﻟﻭﻗﺎﻳﺔ ﻣﻥ ﺍﻟﺣﺭﻳﻖ‪.‬‬
‫ﺃﻥ ﻳﻛﻭﻥ ﻓﺭﺍﻍ ﺍﻟﺳﺩﺓ ﻣﺗﺻﻼ ﺑﺑﺎﻗﻲ ﻓﺭﺍﻍ ﺍﻟﻣﻌﺭﺽ ﺃﻭ ﺍﻟﺩﻛﺎﻥ ﻭﺃﻥ ﺗﻛﻭﻥ‬ ‫•‬
‫ﺍﻟﺳﺩﺓ ﻣﺯﻭﺩﺓ ﺑﺣﺎﺟﺯ )ﺩﺭﺍﺑﺯﻳﻥ( ﺑﺈﺭﺗﻔﺎﻉ ‪ 90‬ﺳﻡ ﻭﺳﻠﻡ ﻳﺅﺩﻱ ﺇﻟﻳﻬﺎ ﻣﻥ‬
‫ﺩﺍﺧﻝ ﺍﻟﻣﻌﺭﺽ ﺃﻭ ﺍﻟﺩﻛﺎﻥ ﻣﻥ ﺍﻟﺧﺭﺳﺎﻧﺔ ﺃﻭ ﺍﻟﺣﺩﻳﺩ ﺃﻭ ﺍﻟﺧﺷﺏ‪.‬‬
‫ﻳﻘﺗﺻﺭ ﺇﺳﺗﻌﻣﺎﻝ ﺍﻟﺳﺩﺓ ﻋﻠﻰ ﺍﻟﺧﺩﻣﺔ ﺍﻟﻣﺑﺎﺷﺭﺓ ﻟﻠﻣﻌﺭﺽ ﺃﻭ ﺍﻟﺩﻛﺎﻥ‪.‬‬ ‫•‬
‫ﻳﺣﺩﺩ ﺇﺭﺗﻔﺎﻉ ﺍﻟﺳﺩﺓ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻭﻓﻘﺎ ﻟﻠﺷﺭﻭﻁ ﺍﻟﺧﺎﺻﺔ ﺑﺎﻹﺭﺗﻔﺎﻋﺎﺕ‬ ‫•‬
‫ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻟﻭﺍﺭﺩﺓ ﺑﻬﺫﺍﺍﻟﻧﻅﺎﻡ‪.‬‬
‫ﺃﻻ ﻳﺳﻣﺢ ﺑﺑﺭﻭﺯ ﺍﻟﺳﺩﺓ ﺧﺎﺭﺝ ﺣﺩﻭﺩ ﺍﻟﻣﺳﻘﻁ ﺍﻷﻓﻘﻲ ﻟﻠﻣﻌﺭﺽ ﺃﻭﺍﻟﺩﻛﺎﻥ‪.‬‬ ‫•‬

‫ﺛﺎﻧﻳﺎ‪ -‬ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺳﻛﻧﻳﺔ ﻭﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻭﺍﻟﺻﻧﺎﻋﻲ‪:‬‬


‫ﻳﻣﻛﻥ ﺍﻟﺳﻣﺎﺡ ﺑﺎﻟﻁﺎﺑﻖ ﺍﻟﺩﺍﺧﻠﻲ) ﺍﻟﻣﻳﺯﺍﻧﻳﻥ(ﻛﻁﺎﺑﻖ ﻣﻧﻔﺻﻝ ﻭﺫﻟﻙ ﺑﺎﻷﺑﻧﻳﺔ‬
‫ﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﺗﺟﺎﺭﻳﺔ ﺑﻧﺳﺑﺔ ‪ 100%‬ﺷﺭﻳﻁﺔ ﺍﻟﺗﺎﻟﻲ‪:-‬‬
‫• ﺃﻥ ﻳﻘﺗﺻﺭ ﺍﺳﺗﻌﻣﺎﻝ ﻫﺫﺍ ﺍﻟﻁﺎﺑﻖ ﻋﻠﻰ ﺍﻹﺳﺗﻌﻣﺎﻝ ﺍﻹﺩﺍﺭﻱ ﻓﻘﻁ )ﻣﻛﺎﺗﺏ( ﺃﻭ‬
‫ﻟﻣﻭﻗﻑ ﻟﻠﺳﻳﺎﺭﺍﺕ‪.‬‬
‫‪.2‬ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﻭﺭﺵ ﻭﺍﻟﻣﺻﺎﻧﻊ ﻭﺍﻟﻣﺧﺎﺯﻥ ﺍﻟﻣﺷﻳﺩﺓ ﻣﻥ ﺍﻟﺷﺑﺭﺍﺕ) ﺍﻟﺟﻣﺎﻟﻭﻧﺎﺕ (‬
‫ﻳﺳﻣﺢ ﺑﺎﻟﺳﺩﺓ ﻓﻲ ﺣﺩﻭﺩ ‪ 30%‬ﻣﻥ ﺍﻟﻣﺳﺎﺣﺔ ﺍﻟﻣﺳﺗﻐﻠﺔ ﻟﻠﻭﺭﺷﺔ ﺃﻭ ﺍﻟﻣﺻﻧﻊ ﺃﻭ‬
‫ﺍﻟﻣﺧﺯﻥ‪.‬‬
‫‪.3‬ﻳﻘﺗﺻﺭﺇﺳﺗﻌﻣﺎﻝ ﺍﻟﺳﺩﺓ ﻟﻠﻣﻛﺎﺗﺏ ﺃﻭ ﺍﻟﺗﺧﺯﻳﻥ‪.‬‬
‫ﺍﻟﺳـــــﻼﻟـــــﻡ‬ ‫•‬
‫ﻳﺟﺏ ﺗﻭﻓﻳﺭ ﻋﺩﺓ ﺳﻼﻟﻡ ﺧﻼﻓﺎ ﻟﻣﺧﺎﺭﺝ ﻭﺳﻼﻟﻡ ﺍﻟﺣﺭﻳﻖ ﻓﻲ ﻛﻝ ﺑﻧﺎء ﻣﻛﻭﻥ‬ ‫•‬
‫ﻣﻥ ﺃﻛﺛﺭ ﻣﻥ ﻁﺎﺑﻖ ﻭﻓﻘﺎ ﻟﻶﺗﻲ‪:‬‬
‫• ﺳﻠﻡ ﺭﺋﻳﺳﻲ ﻭﺍﺣﺩ ﻋﻠﻰ ﺍﻷﻗﻝ ﻟﻛﻝ ﺑﻧﺎء ﻻ ﺗﺯﻳﺩ ﻣﺳﺎﺣﺔ ﺍﻟﻁﺎﺑﻖ‬
‫ﺍﻟﻭﺍﺣﺩ ﻓﻳﻪ ﻋﻠﻰ ‪ 500‬ﻣﺗﺭ ﻣﺭﺑﻊ ﻭﻻ ﻳﺯﻳﺩ ﻋﻠﻰ ‪ 1500‬ﻣﺗﺭ‬
‫ﻣﺭﺑﻊ ﻟﻠﺑﻧﺎء ﻓﻲ ﻣﺟﻣﻭﻋﺔ )ﻣﺟﻣﻭﻉ ﻣﺳﺎﺣﺎﺕ ﺍﻟﻁﻭﺍﺑﻖ ﺑﻣﺎ ﻓﻳﻬﺎ‬
‫ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ(‪.‬‬
‫• ﺳﻠﻡ ﺛﺎﻧﻭﻱ ﺇﺿﺎﻓﻲ ﻟﻛﻝ ‪500‬ﻣﺗﺭ ﻣﺭﺑﻊ ﺇﺿﺎﻓﺔ ﻓﻲ ﻣﺳﺎﺣﺔ‬
‫ﺍﻟﻁﺎﺑﻖ ﺍﻟﻭﺍﺣﺩ ﺃﻭ ﻟﻛﻝ‪ 1500‬ﻣﺗﺭ ﻣﺭﺑﻊ ﺇﺿﺎﻓﺔ ﻓﻲ ﻣﺟﻣﻭﻋﺔ‬
‫ﻣﺳﺎﺣﺔ ﺍﻟﺑﻧﺎء‪.‬‬
‫ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﺍﻟﺻﺎﻓﻲ ﻟﻠﻁﻭﻝ ﺍﻟﻅﺎﻫﺭ ﻟﺩﺭﺟﺔ ﺍﻟﺳﻠﻡ ﺍﻟﺭﺋﻳﺳﻲ ﻭﻓﻘﺎ‬ ‫•‬
‫ﻟﻶﺗﻲ‪:-‬‬
‫• ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺳﻛﻧﻳﺔ ﺃﻭ ﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﺗﺟﺎﺭﻳﺔ ‪1.10 :‬ﻣﺗﺭ ﻭﺫﻟﻙ ﺇﺫﺍ ﻛﺎﻥ‬
‫ﺍﻟﺳﻠﻡ ﻳﺧﺩﻡ ‪ 3‬ﻭﺣﺩﺍﺕ ﺳﻛﻧﻳﺔ ﺑﺎﻟﻁﺎﺑﻖ ﻭﺑﺣﺩ ﺃﻗﺻﻰ ‪ 12‬ﻭﺣﺩﺓ ﻓﻲ‬
‫ﺟﻣﻳﻊ ﺍﻟﻁﻭﺍﺑﻖ ‪ 1.20‬ﻣﺗﺭ ﺇﺫﺍ ﺯﺍﺩ ﻣﺟﻣﻭﻉ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺳﻛﻧﻳﺔ‬
‫ﻋﻠﻰ ‪ 12‬ﻭﺣﺩﺓ‪.‬‬
‫• ﺍﻟﻣﺑﺎﻧﻰ ﺍﻟﻌﺎﻣﺔ )ﻣﺳﺗﺷﻔﻳﺎﺕ– ﻣﺩﺍﺭﺱ ‪-‬ﻓﻧﺎﺩﻕ ﻭﻣﺎﻓﻲ ﺣﻛﻡ‬
‫ﺫﻟﻙ(‪1.40:‬ﻣﺗﺭ ﻭﺗﺳﺗﺛﻧﻰ ﺍﻟﺳﻼﻟﻡ ﺍﻟﺗﻲ ﺗﺳﺗﻌﻣﻝ ﻷﻏﺭﺍﺽ ﺧﺎﺻﺔ‬
‫ﺃﻭ ﺻﻧﺎﻋﻳﺔ ﺃﻭ ﺳﻼﻟﻡ ﺍﻟﻣﺂﺫﻥ ﻣﻥ ﺍﻟﺷﺭﻭﻁ ﺍﻟﻣﻧﺻﻭﺹ ﻋﻠﻳﻬﺎ‬
‫ﺍﻟﺳﺎﺑﻘﺔ ﻛﻣﺎ ﻳﺟﻭﺯ ﺇﺳﺗﺛﻧﺎء ﻁﻭﻝ ﺩﺭﺟﺔ ﺍﻟﺳﻠﻡ ﺑﺎﻟﻣﺳﺎﻛﻥ ﺍﻟﺧﺎﺻﺔ‬
‫ﻭﺍﻟﻔﻳﻼﺕ ﻟﺣﺩ ﺃﺩﻧﻰ)‪ (1‬ﻣﺗﺭ‪.‬‬
‫ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻟﻠﻣﺳﺎﻓﺔ ﺍﻷﻓﻘﻳﺔ ﺍﻟﺗﻲ ﻳﺧﺩﻣﻬﺎ ﺍﻟﺳﻠﻡ ‪27‬ﻣﺗﺭﺍ‪.‬‬ ‫•‬
‫ﻳﺷﺗﺭﻁ ﺃﻻ ﺗﺯﻳﺩ ﻣﺟﻣﻭﻉ ﻋﺩﺩ ﺍﻟﺩﺭﺟﺎﺕ ﺍﻟﻣﺗﻭﺍﻟﻳﺔ ﻓﻲ ﺇﺗﺟﺎﻩ ﻭﺍﺣﺩ‬ ‫•‬
‫ﻭﺍﻟﻣﺣﺻﻭﺭ ﺑﻳﻥ ﺑﺎﺩﺉ ﺍﻟﺳﻠﻡ ﻭﺍﻟﺻﺩﻓﺔ( ﺍﺳﺗﺭﺍﺣﺔ ﺍﻟﺳﻠﻡ )ﻋﻠﻰ ‪14‬‬
‫ﺩﺭﺟﺔ ﻭﻳﺳﺗﺛﻧﻲ ﻣﻥ ﺫﻟﻙ ﺍﻟﺳﻼﻟﻡ ﺍﻟﺧﺎﺭﺟﻳﺔ ﺍﻟﻣﻛﺷﻭﻓﺔ ﻟﺑﻧﺎء ﺑﺈﺭﺗﻔﺎﻉ‬
‫ﻁﺎﺑﻖ ﻭﺍﺣﺩ ﻭﺃﻳﺿﺎ ﺍﻟﺳﻼﻟﻡ ﺍﻟﺗﻲ ﺗﺳﺗﺧﺩﻡ ﻷﻏﺭﺍﺽ ﺧﺎﺻﺔ )ﺳﻼﻟﻡ‬
‫ﺍﻟﻣﺂﺫﻥ ﻭﺍﻻﺑﺭﺍﺝ ﺍﻟﺳﻼﻟﻡ ﺍﻟﺩﺍﺋﺭﻳﺔ‪...‬ﺍﻟﺦ(‬
‫ﻳﺷﺗﺭﻁ ﺃﻥ ﻻ ﻳﻘﻝ ﻋﺭﺽ ﺩﺭﺟﺔ ﺍﻟﺳﻠﻡ ﻋﻥ ‪ 28‬ﺳﻡ ﻭﺃﻻ ﻳﺯﻳﺩ ﻋﻥ ‪ 32‬ﺳﻡ‬ ‫•‬

‫ﻛﻣﺎ ﻳﺷﺗﺭﻁ ﺃﻻ ﻳﻘﻝ ﺇﺭﺗﻔﺎﻉ ﺍﻟﺩﺭﺟﺔ ﻋﻥ ‪ 14‬ﺳﻡ ﻭﻻﻳﺯﻳﺩ ﻋﻥ ‪ 17‬ﺳﻡ‪.‬‬


‫×‪2‬ﺇﺭﺗﻔﺎﻉ ﺍﻟﺩﺭﺟﺔ ‪ +‬ﻋﺭﺽ ﺍﻟﺩﺭﺟﺔ ‪ +‬ﻣﻥ‪ 60‬ﺇﻟﻰ ‪ 64‬ﺳﻡ‬ ‫•‬

‫ﺗﺣﺩﺩ ﺣﺳﺎﺑﺎﺕ ﺃﺑﻌﺎﺩ ﻋﺭﺽ ﻭﺇﺭﺗﻔﺎﻉ ﺩﺭﺟﺔ ﺍﻟﺳﻠﻡ ﻭﻓﻘﺎ ﻟﻠﻣﻌﺎﺩﻟﺔ ﺍﻟﺗﺎﻟﻳﺔ‪:‬‬ ‫•‬

‫(‬ ‫ﻻﻳﺟﻭﺯ ﺃﻥ ﻳﻘﻝ ﺻﺎﻓﻲ ﺍﻹﺭﺗﻔﺎﻉ ﺑﻳﻥ ﺑﻼﻁﺔ ﺍﻟﺻﺩﻓﺔ )ﺇﺳﺗﺭﺍﺣﺔ ﺍﻟﺳﻠﻡ‬ ‫•‬
‫ﻭﺑﻳﻥ ﺑﻼﻁﺔ ﺍﻟﺻﺩﻓﺔ ﺍﻟﺗﻲ ﺗﻠﻳﻬﺎ ﺃﻭ ﺑﻼﻁﺔ ﺍﻟﻁﺎﺑﻖ ﻋﻥ ‪ 2.25‬ﻣﺗﺭ‪.‬‬
‫ﻳﺷﺗﺭﻁ ﺃﻻ ﻳﻘﻝ ﻋﺭﺽ ﺍﻟﺻﺩﻓﺔ) ﺇﺳﺗﺭﺍﺣﺔ ﺍﻟﺳﻠﻡ (ﻋﻥ ﻁﻭﻝ ﺩﺭﺝ ﺍﻟﺳﻠﻡ‪.‬‬ ‫•‬
‫ﻳﺷﺗﺭﻁ ﺃﻻ ﻳﻘﻝ ﺇﺭﺗﻔﺎﻉ ﺣﺎﺟﺯ ﺃﻣﺎﻥ ﺍﻟﺳﻠﻡ ‪ 90‬ﺳﻡ‪.‬‬ ‫•‬

‫ﺍﻟﻣﻣﺭﺍﺕ ﻭﺍﻟﻁﺭﻗﺎﺕ‬ ‫•‬


‫ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻟﻌﺭﺽ ﺍﻟﻣﻣﺭﺍﺕ ﻭﺍﻟﻁﺭﻗﺎﺕ ﺑﺎﻟﻣﺑﺎﻧﻲ ﻭﻓﻘﺎ ﺑﻣﺎ ﻳﻠﻲ‪:-‬‬ ‫•‬
‫‪.‬ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺳﻛﻧﻳﺔ‪.‬‬ ‫•‬
‫• ﻣﻣﺭﺍﺕ ﺩﺍﺧﻝ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺳﻛﻧﻳﺔ ‪ 1.20‬ﻣﺗﺭ‬
‫ﻣﻣﺭ ﻋﺎﻡ ﻳﺅﺩﻱ ﻟﻠﻭﺣﺩﺍﺕ ﻻ ﻳﻘﻝ ﻋﻥ ‪ 1.80‬ﻣﺗﺭ ﻭﻳﺟﻭﺯ ﺇﺳﺗﺛﻧﺎء‬ ‫•‬
‫ﺍﻟﻣﻣﺭﺍﺕ ﺫﺍﺕ ﺍﻷﻁﻭﺍﻝ ﺍﻟﻘﺻﻳﺭﺓ ﻭﺍﻟﺗﻲ ﺗﺧﺩﻡ ﻋﺩﺩ ﻭﺣﺩﺍﺕ ﻻ ﻳﺯﻳﺩ‬
‫ﻋﻥ ﺛﻼﺙ ﺷﻘﻖ ﻣﻥ ﻫﺫﺍ ﺍﻟﺷﺭﻁ ﺣﻳﺙ ﻳﻣﻛﻥ ﺃﻥ ﻳﻛﻭﻥ ﻋﺭﺿﻪ‬
‫‪1.50‬ﻣﺗﺭ ﻓﻲ ﻫﺫﻩ ﺍﻟﺣﺎﻟﺔ‪.‬‬
‫‪2-‬ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﻌﺎﻣﺔ ‪ :‬ﺗﺗﺑﻊ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻘﻳﺎﺳﻳﺔ ﺍﻟﻌﺎﻟﻣﻳﺔ‬ ‫•‬
‫ﻭﺍﻟﻣﺗﻌﺎﺭﻑ ﻋﻠﻳﻬﺎ‪.‬‬
‫(‬ ‫ﺍﻟﻌﺭﺍﺋﺵ)ﺍﻟﺑﺭﺟﻭﻻﺕ‬ ‫•‬
‫ﻳﺻﺭﺡ ﺑﺈﻧﺷﺎء ﺍﻟﻌﺭﺍﺋﺵ ﺣﻭﻝ ﺍﻷﺑﻧﻳﺔ ﻓﻲ ﺍﻟﻣﺳﺎﺣﺎﺕ ﺍﻟﺧﺎﻟﻳﺔ ﻣﻥ ﺍﻷﺭﺽ‬ ‫•‬
‫ﻓﻲ ﺍﻹﺭﺗﺩﺍﺩﺍﺕ ﻭﺑﺣﻳﺙ ﻻﺗﻘﻝ ﻧﺳﺑﺔ ﺍﻟﺗﻔﺭﻳﻎ ﻓﻳﻬﺎ ﻋﻥ )‪ (50%‬ﻣﻥ‬
‫ﻣﺟﻣﻭﻉ ﻣﺳﺎﺣﺗﻬﺎ ﻭﺃﻥ ﻻ ﻳﺯﻳﺩ ﺇﺭﺗﻔﺎﻋﻬﺎ ﻋﻥ)‪ 250‬ﺳﻡ (‪.‬‬
‫ﻳﺻﺭﺡ ﺑﺈﻧﺷﺎء ﻋﺭﺍﺋﺵ) ﺑﺭﺟﻭﻻﺕ ( ﻟﺗﻐﻁﻳﺔ ﺃﺣﻭﺍﺽ ﺍﻟﺳﺑﺎﺣﺔ ﻋﻠﻰ‬ ‫•‬
‫ﺍﻟﺳﻁﺢ ﺑﺷﺭﻁ ﺃﻥ ﻻ ﻳﻘﻝ ﺇﺭﺗﺩﺍﺩﻫﺎ ﻋﻥ ) ‪150‬ﺳﻡ( ﻣﻥ ﺣﺩ ﺍﻟﻣﺑﻧﻰ ﻭﺃﻥ‬
‫ﻻﻳﺯﻳﺩ ﺑﺭﻭﺯﻫﺎ ﻋﻥ)‪ 150‬ﺳﻡ ( ﻣﻥ ﺣﺩﻭﺩ ﺣﻭﺽ ﺍﻟﺳﺑﺎﺣﺔ ﻭﺃﻥ ﻻ ﻳﺯﻳﺩ‬
‫ﺇﺭﺗﻔﺎﻋﻬﺎ ﻋﻥ ) ‪250‬ﺳﻡ( ﻓﻭﻕ ﻣﻧﺳﻭﺏ ﺣﻭﺽ ﺍﻟﺳﺑﺎﺣﺔ‪.‬‬
‫ﺍﻟﻣﺻﺎﻋﺩ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ‬ ‫•‬
‫ﻳﺟﺏ ﺗﺯﻭﻳﺩ ﺃﻱ ﻣﺑﻧﻰ ﻳﺯﻳﺩ ﺇﺭﺗﻔﺎﻋﻪ ﻋﻥ ﺛﻼﺛﺔ ﻁﻭﺍﺑﻖ ﺑﻣﺻﺎﻋﺩ‬ ‫•‬
‫ﻛﻬﺭﺑﺎﺋﻳﺔ ﺗﺗﻧﺎﺳﺏ ﺳﻌﺗﻬﺎ ﻣﻊ ﻣﺳﺎﺣﺔ ﺍﻟﻁﺎﺑﻖ ﻭﻋﺩﺩ ﺍﻟﺷﻘﻖ‪.‬‬
‫ﻓﻲ ﺍﻟﻣﺭﺍﻛﺯ ﺍﻟﺗﺟﺎﺭﻳﺔ ﺍﻟﻣﻛﻭﻧﺔ ﻣﻥ ﺃﻛﺛﺭ ﻣﻥ ﻁﺎﺑﻖ ﻳﺟﺏ ﺗﻭﻓﻳﺭ‬ ‫•‬
‫ﻣﺻﺎﻋﺩ ﻛﻬﺭﺑﺎﺋﻳﺔ ﺑﻭﺍﺟﻬﺔ ﺯﺟﺎﺟﻳﺔ ﻭﺳﻌﺔ )ﻻ ﺗﻘﻝ ﻋﻥ ‪10‬‬
‫ﺃﺷﺧﺎﺹ ﻟﻠﻣﺻﻌﺩ ﺍﻟﻭﺍﺣﺩ(‪.‬‬
‫ﺑﺄﻱ ﺣﺎﻝ ﻣﻥ ﺍﻷﺣﻭﺍﻝ ﻻ ﻳﺟﺏ ﺃﻥ ﺗﻘﻝ ﺳﻌﺔ ﺍﻟﻣﺻﻌﺩ ﻋﻥ ‪4‬‬ ‫•‬
‫ﺃﺷﺧﺎﺹ‪.‬‬
‫ﻏﺭﻓﺔ ﺍﻟﻣﺻﺎﻋﺩ ﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﺑﺄﺑﻌﺎﺩ ﻣﺗﻁﺎﺑﻘﺔ ﻭﻣﻛﻳﻔﺔ ﺍﻟﻬﻭﺍء‬ ‫•‬
‫ﻭﻣﺣﻛﻣﺔ ﺍﻹﻏﻼﻕ ﻭﺃﻥ ﺗﻛﻭﻥ ﺍﻟﻛﺎﺑﻼﺕ ﻣﺧﻔﻳﺔ‪.‬‬
‫ﻳﻛﻭﻥ ﺑﺋﺭ ﺍﻟﻣﺻﻌﺩ ﺑﺎﻷﺑﻌﺎﺩ ﺍﻟﻣﺗﻁﺎﺑﻘﺔ ﻭﺍﻟﻣﺫﻛﻭﺭﺓ ﻣﻥ ﻗﺑﻝ ﺍﻟﺷﺭﻛﺔ‬ ‫•‬
‫ﺍﻟﺻﺎﻧﻌﺔ‪.‬‬
‫ﻣﻌﺎﻟﺟﺔ ﺍﻷﺟﺯﺍء ﺍﻟﻣﻌﺭﺿﺔ ﻟﻠﻣﻳﺎﻩ ﻣﻥ ﺑﺋﺭ ﺍﻟﻣﺻﻌﺩ ﺑﺎﻟﻣﻭﺍﺩ ﺍﻟﻌﺎﺯﻟﺔ‪.‬‬ ‫•‬
‫ﻳﺟﺏ ﺃﻥ ﺗﺯﻭﺩ ﺍﻟﻣﺻﺎﻋﺩ ﺑﺄﻋﻠﻰ ﻣﺳﺗﻭﻯ ﻟﻸﻣﺎﻥ ﻭﺃﻥ ﺗﺯﻭﺩ‬ ‫•‬
‫ﺑﺎﻟﻠﻭﺣﺎﺕ ﺍﻹﺭﺷﺎﺩﻳﺔ ﻭﺣﺩﻭﺩ ﺍﻷﻭﺯﺍﻥ ﻭﻏﻳﺭﻫﺎ ﻣﻥ ﺍﻟﺗﻌﻠﻳﻣﺎﺕ‬
‫ﺍﻷﺧﺭﻯ‪.‬‬
‫ﺍﻹﺿﺎءﺓ ﻭﺍﻟﺗﻬﻭﻳﺔ ﺍﻟﻣﻳﻛﺎﻧﻳﻛﻳﺔ ﻭﺍﻟﺗﻛﻳﻳﻑ ﺍﻟﻣﺭﻛﺯﻱ‬ ‫•‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺗﻌﺫﺭ ﺗﻭﻓﻳﺭ ﺍﻹﺿﺎءﺓ ﻭﺍﻟﺗﻬﻭﻳﺔ ﺍﻟﻁﺑﻳﻌﻳﺔ ﻟﺑﻌﺽ ﺍﻟﻣﺑﺎﻧﻲ‬ ‫•‬
‫ﻣﺛﻝ ﺍﻟﻘﺎﻋﺎﺕ ﻭﺍﻟﻣﺅﺗﻣﺭﺍﺕ ﻭﺍﻟﻣﻁﺎﻋﻡ ﻭﺍﻟﻣﺭﺍﻛﺯ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻓﺈﻧﻪ‬
‫ﻳﺟﻭﺯ ﺍﺳﺗﺑﺩﺍﻟﻬﺎ ﺑﺎﻹﺿﺎءﺓ ﻭﺍﻟﺗﻬﻭﻳﺔ ﺍﻹﺻﻁﻧﺎﻋﻳﺔ ﻭﻓﻘﺎ ﻟﻠﺷﺭﻭﻁ‬
‫ﺍﻟﺗﺎﻟﻳﺔ‪:‬‬
‫• ﺗﻭﻓﻳﺭ ﻧﻅﺎﻡ ﺗﻛﻳﻑ ﻣﺭﻛﺯﻱ ﻭﺇﺿﺎءﺓ ﻛﻬﺭﺑﺎﺋﻳﺔ ﻟﻛﻝ ﻣﺑﻧﻰ‪.‬‬
‫• ﺃﻥ ﺗﻛﻭﻥ ﺩﺭﺍﺳﺎﺕ ﺍﻟﺗﻛﻳﻳﻑ ﻭﺍﻹﺿﺎءﺓ ﺣﺳﺏ ﺍﻟﻣﻘﺎﻳﻳﺱ ﺍﻟﻣﺗﺑﻌﺔ‬
‫ﻋﺎﻟﻣﻳﺎ ً‪.‬‬
‫• ﺃﻥ ﺗﻛﻭﻥ ﻣﺳﺎﺣﺔ ﻭﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻣﻧﺎﻭﺭ ﺍﻟﺗﻲ ﺗﻁﻝ ﻋﻠﻳﻬﺎ‬
‫ﺍﻟﻣﻁﺎﺑﺦ ﺫﺍﺕ ﺍﻟﺗﻬﻭﻳﺔ ﺍﻟﻣﻳﻛﺎﻧﻳﻛﻳﺔ ﻭﻓﻖ ﻣﺎﺟﺎء ﻓﻲ ﺍﻟﻣﺎﺩﺓ‬
‫ﺍﻟﺳﺎﺑﻘﺔ ﺍﻟﻣﺗﻌﻠﻘﺔ ﺑﺷﺭﻁ ﺇﻧﺎﺭﺓ ﻭﺗﻬﻭﻳﺔ ﺍﻹﺳﺗﻌﻣﺎﻻﺕ ﺍﻟﻣﻁﻠﺔ‬
‫ﻋﻠﻰ ﺍﻟﻣﻧﻭﺭ ﻭﺍﻟﻔﻧﺎء ﺍﻟﺩﺍﺧﻠﻲ‪.‬‬
‫• ﺃﻥ ﻳﺗﻡ ﺗﻁﺑﻳﻖ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﻭﺍﻟﺷﺭﻭﻁ ﺍﻟﻭﺍﺭﺩﺓ ﻓﻲ ﻧﻅﺎﻡ ﺍﻟﻌﺯﻝ‬
‫ﺍﻟﺣﺭﺍﺭﻱ ﺍﻟﻣﻌﺗﻣﺩ ﻭﺃﺧﺫ ﺫﻟﻙ ﺑﻌﻳﻥ ﺍﻹﻋﺗﺑﺎﺭ ﻓﻲ ﺣﺳﺎﺑﺎﺕ‬
‫ﺍﻟﺗﻬﻭﻳﺔ ﻭﺍﻟﺗﻛﻳﻳﻑ ﻭﺍﻹﺿﺎءﺓ ﻭﺫﻟﻙ ﻟﻠﺟﺩﺭﺍﻥ ﻭﺍﻷﺳﻘﻑ‬
‫ﻭﺍﻟﻧﻭﺍﻓﺫ‪.‬‬
‫ﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ‬ ‫•‬
‫ﻓﻲ ﺍﻟﺭﺳﻭﻣﺎﺕ ﺍﻟﻬﻧﺩﺳﻳﺔ ﺍﻟﻣﻘﺩﻣﺔ ﻟﻠﺳﻠﻁﺎﺕ ﺍﻟﻔﻧﻳﺔ ﻟﻠﺣﺻﻭﻝ ﻋﻠﻰ‬ ‫•‬
‫ﺗﺭﺧﻳﺹ ﺑﻧﺎء ‪ ،‬ﻳﺟﺏ ﺍﻹﻟﺗﺯﺍﻡ ﺑﺈﺷﺗﺭﺍﻁﺎﺕ ﺩﺍﺋﺭﺓ ﺍﻟﺗﺧﻁﻳﻁ‬
‫ﻭﺍﻟﻣﺳﺎﺣﺔ ﻓﻳﻣﺎ ﻳﺗﻌﻠﻖ ﺑﺗﻭﻓﻳﺭ ﻣﻭﺍﻗﻑ ﻣﺧﺻﺻﺔ ﻟﻠﺳﻳﺎﺭﺍﺕ ﺑﺩﺍﺧﻝ‬
‫ﺍﻟﻘﻁﻊ ﻭﺑﺣﺳﺏ ﺍﻟﻧﺳﺏ ﺍﻟﻣﻘﺭﺭﺓ‪.‬‬
‫ﻻ ﻳﺟﻭﺯ ﻭﺿﻊ ﻣﺩﺍﺧﻝ ﺃﻭ ﻣﺧﺎﺭﺝ ﺍﻟﺳﻳﺎﺭﺍﺕ ﻋﻠﻰ ﻣﻣﺭﺍﺕ ﺍﻟﻣﺷﺎﺓ‬ ‫•‬
‫)ﺍﻟﺳﻛﻙ( ﺃﻭ ﻋﻠﻰ ﺍﻟﻘﻁﻊ ﺍﻟﻣﺧﺻﺻﺔ ﻟﻠﻣﻭﺍﻗﻑ‪.‬‬

‫ﺍﻟﺷﺭﻭﻁ ﺍﻟﻔﻧﻳﺔ ﻟﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ‬ ‫•‬


‫ﻳﺟﺏ ﺃﻥ ﺗﺯﻭﺩ ﺍﻟﻣﻭﺍﻗﻑ ﺑﻌﻼﻣﺎﺕ ﺃﺭﺿﻳﺔ ﻭﻟﻭﺣﺎﺕ ﺇﺭﺷﺎﺭﺩﻳﺔ ﻓﻲ ﺃﻣﺎﻛﻥ‬ ‫•‬
‫ﻭﺍﺿﺣﺔ ﺗﻭﺿﺢ ﺇﺗﺟﺎﻩ ﺍﻟﺩﺧﻭﻝ ﻭﺍﻟﺧﺭﻭﺝ ﻭﺣﺭﻛﺔ ﺍﻟﺳﻳﺭ ﺩﺍﺧﻝ ﺍﻟﻣﻭﺍﻗﻑ‬
‫ﻭﻭﺿﻊ ﺍﻟﻣﺭﺍﻳﺎ ﺍﻟﻌﺎﻛﺳﺔ‪.‬‬
‫ﻳﺟﺏ ﺃﻥ ﺗﺯﻭﺩ ﺑﻣﺻﺩﺍﺕ ﺧﺭﺳﺎﻧﻳﺔ ﻟﻠﻌﺟﻼﺕ ﻟﻣﻧﻊ ﺗﺟﺎﻭﺯ ﺍﻟﺣﺩﻭﺩ ﺍﻷﻣﺎﻣﻳﺔ‬ ‫•‬
‫ﻟﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ‪.‬‬
‫ﺗﺯﻭﺩ ﺍﻷﻋﻣﺩﺓ ﺑﺯﻭﺍﻳﺎ ﻣﻁﺎﻁﻳﺔ ﻣﻧﺎﺳﺑﺔ ﻟﻠﻭﻗﺎﻳﺔ ﺃﺛﻧﺎء ﺣﺭﻛﺔ ﺍﻟﺳﻳﺎﺭﺍﺕ‬ ‫•‬
‫ﺑﺈﺳﺗﺛﻧﺎء ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺃﺭﺻﻔﺔ ﺗﺣﻳﻁ ﺑﺎﻷﻋﻣﺩﺓ‪.‬‬
‫ﺗﺣﺩﻳﺩ ﺍﻷﺭﻗﺎﻡ ﻟﻠﻣﻭﺍﻗﻑ‪.‬‬ ‫•‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻭﻗﻭﻉ ﻗﻁﻌﺔ ﺍﻷﺭﺽ ﻋﻠﻰ ﺷﺎﺭﻋﻳﻥ ﺃﺣﺩﻫﻣﺎ ﻓﺭﻋﻲ ﻭﺍﻵﺧﺭ‬ ‫•‬
‫ﺭﺋﻳﺳﻲ ﻳﻘﺗﺻﺭ ﺍﻟﺳﻣﺎﺡ ﺑﻣﺩﺍﺧﻝ ﻭﻣﺧﺎﺭﺝ ﺍﻟﺳﻳﺎﺭﺍﺕ ﻋﻠﻰ ﺍﻟﺷﺎﺭﻉ ﺍﻟﻔﺭﻋﻲ‬
‫ﻓﻘﻁ‪.‬‬
‫ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻹﺭﺗﻔﺎﻉ ﺳﻘﻑ ﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ ‪ 240‬ﺳﻡ ﻭﺍﻟﺣﺩ ﺍﻷﻗﺻﻰ‬ ‫•‬
‫‪300‬ﺳﻡ‪.‬‬
‫ﺍﻟﺣﺩﻭﺩ ﺍﻟﺩﻧﻳﺎ ﻟﻌﺩﺩ ﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ‬ ‫•‬

‫ﺗﺣﺩﺩ ﺍﻟﺣﺩﻭﺩ ﺍﻟﺩﻧﻳﺎ ﻟﻌﺩﺩ ﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ ﻭﻓﻘﺎ ﻟﻠﺗﺎﻟﻲ‪:‬‬ ‫•‬

‫ﻋﺩﺩ ﺍﻟﻣﻭﺍﻗﻑ‬ ‫ﺍﻟﻣﺳﺎﺣﺔ‬ ‫ﻧﻭﻉ ﺍﻹﺳﺗﻌﻣﺎﻝ‬ ‫ﻡ‬


‫‪1‬ﻣﻭﻗﻑ‬ ‫‪2‬‬
‫ﻟﻛﻝ‪ 80‬ﻡ‬ ‫ﺍﻟﺳﻛﻧﻲ‬ ‫‪1‬‬
‫‪1.2‬ﻣﻭﻗﻑ‬ ‫‪2‬‬
‫ﻟﻛﻝ‪ 120‬ﻡ‬ ‫ﺍﻟﺳﻛﻧﻲ‬ ‫‪2‬‬
‫‪2‬ﻣﻭﻗﻑ‬ ‫‪2‬‬
‫ﻟﻛﻝ‪ 150‬ﻡ‬ ‫ﺍﻟﺳﻛﻧﻲ‬ ‫‪3‬‬
‫‪ 1‬ﻣﻭﻗﻑ‬ ‫‪2‬‬
‫ﻟﻛﻝ‪ 15‬ﻡ‬ ‫ﺍﻟﺗﺟﺎﺭﻱ‬ ‫‪4‬‬

‫ﺍﻟﺣﺩﻭﺩ ﺍﻟﺩﻧﻳﺎ ﻷﺑﻌﺎﺩ ﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ‬ ‫•‬

‫• ﺗﺣﺩﻳﺩ ﺍﻟﺣﺩﻭﺩ ﺍﻟﺩﻧﻳﺎ ﻷﺑﻌﺎﺩ ﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ ﻭﻓﻘﺎ ً ﻟﻠﺗﺎﻟﻲ‪:‬‬


‫ﺃﺑﻌﺎﺩ ﺍﻟﻁﺭﻳﻖ‬ ‫ﺃﺑﻌﺎﺩ ﺍﻟﻣﻭﺍﻗﻑ‬ ‫ﻡ ﻭﺿﻊ ﺍﻟﻣﻭﺍﻗﻑ‬
‫‪3.00‬ﻡ‬ ‫‪6.50X2.50‬‬ ‫‪ 1‬ﻣﻭﺍﻗﻑ ﻣﻭﺍﺯﻳﺔ ﻟﻠﻁﺭﻳﻖ‬
‫‪3.20‬ﻡ‬ ‫‪ 2‬ﻣﻭﺍﻗﻑ ﻋﻠﻰ ﺯﺍﻭﻳﺔ ‪ 45‬ﺩﺭﺟﺔ ‪5.50X2.50‬‬
‫‪3.75‬ﻡ‬ ‫‪ 3‬ﻣﻭﺍﻗﻑ ﻋﻠﻰ ﺯﺍﻭﻳﺔ ‪ 60‬ﺩﺭﺟﺔ ‪5.80X2.50‬‬
‫‪5.50‬ﻡ‬ ‫‪ 4‬ﻣﻭﺍﻗﻑ ﻋﻣﻭﺩﻳﺔ ﻋﻠﻰ ﺍﻟﻁﺭﻳﻖ ‪5.50X2.50‬‬
‫• ﻓﻲ ﺣﺎﻟﺔ ﺗﺧﺻﻳﺹ ﻁﺎﺑﻖ ﻟﻣﻭﺍﻗﻑ ﻟﻠﺳﻳﺎﺭﺍﺕ ﺑﺎﻷﺑﻧﻳﺔ ﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﺗﺟﺎﺭﻳﺔ‬
‫ﻳﺟﺏ ﺩﺭﺍﺳﺔ ﻭﺿﻊ ﺍﻷﻋﻣﺩﺓ ﻭﻁﺭﻳﻖ ﺍﻟﺩﺧﻭﻝ ﻭﺍﻟﺧﺭﻭﺝ ﻟﻠﺳﻳﺎﺭﺍﺕ ﺑﺩﻭﻥ‬
‫ﻋﺎﺋﻖ‪.‬‬

‫ﺍﻹﺷﺗﺭﺍﻁﺎﺕ ﺍﻟﺑﻳﺋﻳﺔ‪:‬‬ ‫•‬

‫ﺍﻟﻣﺅﺛﺭﺍﺕ ﺍﻟﺑﻳﺋﻳﺔ‬
‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺕ ﺍﻟﻣﺅﺛﺭﺍﺕ ﺍﻟﺑﻳﺋﻳﺔ ﺍﻟﻣﺧﺗﻠﻔﺔ ) ﻛﺎﻟﻅﺭﻭﻑ ﺍﻟﺟﻭﻳﺔ‪ ،‬ﺃﺷﻌﺔ‬ ‫•‬

‫ﺍﻟﺷﻣﺱ‪ ،‬ﻁﺑﻳﻌﺔ ﺍﻷﺭﺽ‪ ،‬ﺍﻟﺟﻭﺍﺭ‪ ،‬ﻣﺳﺗﻭﻯ ﺍﻟﺿﻭﺿﺎء‪ ،‬ﺍﻟﻣﻠﻭﺛﺎﺕ ﺍﻟﺑﻳﺋﻳﺔ(‬

‫ﻛﻣﺎ ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺷﺭﻭﻁ ﻭﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺧﺎﺻﺔ ﺑﺄﻋﻣﺎﻝ ﺍﻟﻌﺯﻝ ﺍﻟﺣﺭﺍﺭﻱ‬


‫ﺍﻟﻣﻌﺗﻣﺩﺓ ﻋﻧﺩ ﺇﻋﺩﺍﺩ ﺗﺻﺎﻣﻳﻡ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﻣﺧﺗﻠﻔﺔ‪.‬‬
‫ﻳﺟﺏ ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﺍﻟﺣﺻﻭﻝ ﻋﻠﻰ ﻣﻭﺍﻓﻘﺔ ﻗﺳﻡ ﺍﻟﺑﻳﺋﺔ ﻓﻲ‬ ‫•‬

‫ﺍﻟﺑﻠﺩﻳﺔ ﻋﻠﻰ ﺍﻟﻣﺷﺎﺭﻳﻊ ﺍﻟﺗﻲ ﺗﺷﻣﻝ ﺗﻠﻭﺛﺎ ً ﺑﻳﺋﻳﺎ ً ﻣﻬﻣﺎ ﻛﺎﻥ ﻧﻭﻋﻪ‪ ،‬ﻭﻋﻠﻳﻪ‬
‫ﺗﻁﺑﻳﻖ ﻛﺎﻓﺔ ﺍﻟﺷﺭﻭﻁ ﺍﻟﺗﻲ ﺗﺗﻌﻠﻖ ﺑﺣﻣﺎﻳﺔ ﺍﻟﺑﻳﺋﺔ ﻭﺍﻟﻣﻌﺗﻣﺩﺓ ﻟﺩﻯ ﺍﻟﻘﺳﻡ‬
‫ﺍﻟﻣﺧﺗﺹ‪.‬‬
‫ﻳﺣﻖ ﻟﻠﻘﺳﻡ ﺍﻟﻣﺧﺗﺹ ﻁﻠﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺗﺄﺛﻳﺭ ﺍﻟﺑﻳﺋﻲ ﺑﻣﺎ ﻓﻲ ﻟﻙ ﺇﺟﺭﺍء‬ ‫•‬

‫ﺗﻌﺩﻳﻼﺕ ﺃﻭ ﺇﻟﻐﺎء ﺃﻱ ﺭﺧﺻﺔ ﺃﻋﻣﺎﻝ ﺑﻧﺎء ﺻﺎﺩﺭﺓ ﺇﻥ ﺗﺑﻳﻥ ﺃﻥ ﺍﻟﻣﺑﻧﻰ ﺃﻭ‬


‫ﺍﻹﺳﺗﻌﻣﺎﻝ ﻓﻳﻪ ﻳﺳﺑﺏ ﻣﺧﺎﻁﺭ ﺑﻳﺋﻳﺔ‪.‬‬
‫ﻳﺟﺏ ﺍﻟﻌﻣﻝ ﻋﻠﻰ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﻌﺯﻝ ﺍﻟﺣﺭﺍﺭﻱ ﻭﺍﻟﺻﻭﺗﻲ ﻓﻲ ﺍﻷﺳﻘﻑ‬ ‫•‬

‫ﻭﺍﻟﺟﺩﺭﺍﻥ ﻟﻐﺭﺽ ﺗﺭﺷﻳﺩ ﺍﺳﺗﻬﻼﻙ ﺍﻟﻁﺎﻗﺔ ﻭﻣﻘﺎﻭﻣﺔ ﻋﻭﺍﻣﻝ ﺍﻟﺑﻳﺋﺔ ﻁﺑﻘﺎ ً‬


‫ﻟﻠﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻔﻧﻳﺔ ﻭﺍﻟﺧﺎﺻﺔ ﺑﺎﻟﻌﺯﻝ ﺍﻟﺣﺭﺍﺭﻱ‪.‬‬
‫ﻳﺟﺏ ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﺩﺭﺍﺳﺔ ﺇﺗﺟﺎﻫﺎﺕ ﺃﺷﻌﺔ ﺍﻟﺷﻣﺱ‬ ‫•‬

‫ﻭﺗﻭﻅﻳﻑ ﺍﻟﻌﻧﺎﺻﺭ ﺍﻟﻣﻌﻣﺎﺭﻳﺔ ﻟﻠﺣﺩ ﻣﻥ ﺍﻵﺛﺎﺭ ﺍﻟﺳﻠﺑﻳﺔ ﻟﻬﺎ ﻭﺩﺭﺍﺳﺔ‬


‫ﺇﺗﺟﺎﻫﺎﺕ ﺍﻟﺭﻳﺎﺡ ﺍﻟﺳﺎﺋﺩﺓ ﻭﺍﻟﻌﻣﻝ ﻋﻠﻰ ﺗﻭﻅﻳﻔﻬﺎ ﻟﺻﺎﻟﺢ ﺍﻟﻣﺑﻧﻰ‪.‬‬
‫ﻳﺟﺏ ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﺍﻟﻌﻣﻝ ﻋﻠﻰ ﺇﺧﺗﻳﺎﺭ ﺍﻟﻣﻭﺍﺩ ﺍﻟﺗﻲ ﻻ ﺗﻠﺣﻖ‬ ‫•‬

‫ﺃﺿﺭﺍﺭﺍ ً ﺑﺎﻟﺑﻳﺋﺔ ﻭﺍﻟﺻﺣﺔ ﺍﻟﻌﺎﻣﺔ ﺃﻭ ﺗﺷﻭﻩ ﺍﻟﻣﻧﻅﺭ ﺍﻟﻌﺎﻡ ﻟﻠﻣﺩﻳﻧﺔ ﻛﺎﻟﻣﻧﺷﺂﺕ‬


‫ﺍﻟﻣﺅﻗﺗﺔ ﺳﻭﺍء ﻋﻧﺩ ﺍﺳﺗﻌﻣﺎﻟﻬﺎ ﺃﻭ ﺑﻌﺩ ﺍﻻﻧﺗﻬﺎء ﻣﻥ ﺍﺳﺗﻌﻣﺎﻟﻬﺎ ﻁﺑﻘﺎ ً ﻟﻣﺎ‬
‫ﺗﺣﺩﺩﻩ ﺍﻹﺩﺍﺭﺓ ﺍﻟﻣﺧﺗﺻﺔ‪.‬‬
‫ﻳﺟﺏ ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﻣﺭﺍﻋﺎﺓ ﻅﺭﻭﻑ ﺍﻟﺻﺣﺔ ﺍﻟﻌﺎﻣﺔ ﺩﺍﺧﻝ‬ ‫•‬

‫ﺍﻟﻣﺑﻧﻰ ﻭﺧﺎﺭﺟﻪ ﻣﻥ ﺣﻳﺙ ﺩﺭﺍﺳﺔ ﺣﺭﻛﺔ ﻭﻛﻣﻳﺔ ﺍﻟﺗﻬﻭﻳﺔ ﻭﺍﻹﺿﺎءﺓ‪،‬‬


‫ﻭﺃﺷﻌﺔ ﺍﻟﺷﻣﺱ ﻭﺍﻟﻅﻼﻝ‪ ،‬ﻭﺍﺧﺗﻳﺎﺭ ﺍﻟﻣﻭﺍﺩ ﻭﺍﻷﺻﺑﺎﻍ ﻭﺧﻼﻓﻬﺎ‪.‬‬
‫ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﺍﻟﻌﻣﻝ ﻋﻠﻰ ﺇﺳﺗﺧﺩﺍﻡ ﺍﻟﻣﺑﻳﺩﺍﺕ ﺍﻟﺣﺷﺭﻳﺔ‬ ‫•‬

‫ﺍﻟﻣﻌﺗﻣﺩﺓ ﻟﻣﻛﺎﻓﺣﺔ ﺍﻟﺣﺷﺭﺍﺕ ﺑﻣﺎ ﻓﻲ ﺫﻟﻙ ﺍﻟﻧﻣﻝ ﺍﻷﺑﻳﺽ ﻓﻲ ﺃﺭﺿﻳﺎﺕ‬


‫ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﻭﺣﻳﺛﻣﺎ ﻳﻠﺯﻡ ﺫﻟﻙ‪.‬‬
‫ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺧﺻﻭﺻﻳﺔ ﻋﻧﺩ ﺇﻋﺩﺍﺩ ﺗﺻﺎﻣﻳﻡ‬ ‫•‬

‫ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﻣﺧﺗﻠﻔﺔ ﻭﻳﺟﺏ ﻋﻣﻝ ﺃﺳﻭﺍﺭ ﺑﺈﺭﺗﻔﺎﻉ ﻭﺗﺻﺎﻣﻳﻡ ﻣﻧﺎﺳﺑﺔ ﺗﻭﺍﻓﻖ‬


‫ﻋﻠﻳﻬﺎ ﺍﻹﺩﺍﺭﺓ ﺍﻟﻣﺧﺗﺻﺔ ﻟﻠﻔﺻﻝ ﺑﻳﻥ ﺍﻷﺭﺍﺿﻲ ﺍﻟﻣﺧﺗﻠﻔﺔ‪.‬‬
‫• ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﺍﻟﺗﻘﻳﺩ ﺑﺄﺣﻛﺎﻡ ﺗﺷﺭﻳﻌﺎﺕ ﺣﻣﺎﻳﺔ ﺍﻟﺑﻳﺋﺔ ﺍﻟﻣﺣﻠﻳﺔ‬
‫ﻭﺍﻹﺗﺣﺎﺩﻳﺔ ﻓﻲ ﻛﻝ ﻣﺎ ﻳﺗﻌﻠﻖ ﺑﺈﻋﺎﺩﺓ ﺍﺳﺗﺧﺩﺍﻡ ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﻭﺍﻟﺗﺧﻠﺹ ﻣﻧﻬﺎ‬
‫ﻭﺭﻗﺎﺑﺔ ﺗﻠﻭﺙ ﺍﻟﻬﻭﺍء ﻭﺍﻟﺻﺣﺔ ﺍﻟﻣﻬﻧﻳﺔ ﻭﺍﻟﻣﺳﺎﺑﺢ ﻭﺳﻼﻣﺔ ﺃﻟﻌﺎﺏ ﺍﻷﻁﻔﺎﻝ‬
‫ﺍﻟﻣﺗﻭﻓﺭﺓ ﻓﻲ ﺍﻟﻣﺑﺎﻧﻲ ﻭﻣﻛﺎﻓﺣﺔ ﺍﻟﺿﺟﻳﺞ ﻭﺃﻧﻅﻣﺔ ﺍﻟﻣﺣﻣﻳﺎﺕ ﺍﻟﻁﺑﻳﻌﻳﺔ‪.‬‬
‫• ﻻ ﻳﺻﺭﺡ ﺑﺈﺯﺍﻟﺔ ﺃﻭ ﻗﻁﻊ ﺃﻱ ﻣﻥ ﺍﻷﺷﺟﺎﺭ ﺍﻟﻣﻌﻣﺭﺓ ﻭﺍﻟﻘﺎﺋﻣﺔ ﺿﻣﻥ ﺣﺩﻭﺩ‬
‫ﺍﻷﺭﺽ ﺇﻻ ﺑﻌﺩ ﺍﻟﺣﺻﻭﻝ ﻋﻠﻰ ﺍﻟﻣﻭﺍﻓﻘﺔ ﺍﻟﺧﻁﻳﺔ ﺍﻟﻼﺯﻣﺔ ﻟﺫﻟﻙ ﻣﻥ ﺩﺍﺋﺭﺓ‬
‫ﺍﻷﺷﻐﺎﻝ ﺍﻟﻌﺎﻣﺔ‪.‬‬
‫• ﻳﺟﺏ ﺃﻥ ﻻ ﻳﺯﻳﺩ ﺍﻟﺣﺩ ﺍﻷﻋﻠﻰ ﻟﻣﺳﺗﻭﻯ ﺍﻟﺿﺟﻳﺞ ﺍﻟﻧﺎﺗﺞ ﻋﻥ ﺃﻳﺔ ﺃﺟﻬﺯﺓ ﺃﻭ‬
‫ﺃﻋﻣﺎﻝ ﻋﻥ )‪ (55‬ﺩﻳﺳﺑﻝ"ﻭﺣﺩﺓ ﻗﻳﺎﺱ ﺍﻹﻫﺗﺯﺍﺯ "ﺧﻼﻝ ﺍﻟﻔﺗﺭﺓ ﻣﻥ ﺍﻟﺳﺎﺑﻌﺔ‬
‫ﺻﺑﺎﺣﺎ ﻭﺣﺗﻰ ﺍﻟﺛﺎﻣﻧﺔ ﻣﺳﺎءﺍ ً ﻭﺃﻻ ﻳﺯﻳﺩ ﻋﻥ )‪ (45‬ﺩﻳﺳﺑﻝ ﺧﻼﻝ ﺍﻟﻔﺗﺭﺓ ﻣﻥ‬
‫ﺍﻟﺛﺎﻣﻧﺔ ﻣﺳﺎ ًءﺍ ﻭﺣﺗﻰ ﺍﻟﺳﺎﻋﺔ ﺍﻟﺳﺎﺑﻌﺔ ﺻﺑﺎ ًﺣﺎ‪.‬‬
‫• ﻻ ﻳﺻﺭﺡ ﺑﻬﺩﻡ ﺃﻭ ﺇﺯﺍﻟﺔ ﺃﻭ ﺗﻌﺩﻳﻝ ﺍﻟﻣﺑﺎﻧﻲ ﻭﺍﻟﻌﻧﺎﺻﺭ ﺍﻟﻣﻌﻣﺎﺭﻳﺔ ﺍﻟﺗﺭﺍﺛﻳﺔ‬
‫ﻭﻳﺟﺏ ﻣﺭﺍﺟﻌﺔ ﺍﻹﺩﺍﺭﺓ ﺍﻟﻣﻌﻳﻧﺔ ﻗﺑﻝ ﺍﻟﻘﻳﺎﻡ ﺑﺄﻳﺔ ﺃﻋﻣﺎﻝ ﺑﻧﺎء ﺃﻭ ﻫﺩﻡ ﻓﻲ ﻫﺫﻩ‬
‫ﺍﻟﻣﺑﺎﻧﻲ ﻭﻛﺫﻟﻙ ﻳﺟﺏ ﺍﻟﺣﺻﻭﻝ ﻋﻠﻰ ﻣﻭﺍﻓﻘﺔ ﺍﻹﺩﺍﺭﺓ ﺍﻟﻣﺧﺗﺻﺔ‪.‬‬
‫• ﻳﺟﺏ ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﻭﻗﻑ ﺍﻟﻌﻣﻝ ﻭﺇﺑﻼﻍ ﺍﻟﺑﻠﺩﻳﺔ ﻓﻭﺭﺍ ﻋﻧﺩ‬
‫ﺍﻟﻌﺛﻭﺭ ﻋﻠﻰ ﺁﺛﺎﺭ ﺃﻭ ﻣﻭﺍﻗﻊ ﺃﺛﺭﻳﺔ ﺃﻭ ﺇﻟﺣﺎﻕ ﺃﺿﺭﺍﺭ ﺑﺧﻁﻭﻁ ﺍﻟﺧﺩﻣﺎﺕ ﺃﻭ‬
‫ﺍﻟﻣﺑﺎﻧﻲ ﺃﻭ ﺍﻟﺷﻭﺍﺭﻉ ﺃﻭ ﺍﻟﺑﻳﺋﺔ ﺍﻟﻣﺣﻳﻁﺔ‪.‬‬

‫ﺍﻟﺗﺄﺛﻳﺭﺍﺕ ﺍﻟﺑﻳﺋﺔ ﺍﻟﺿﺎﺭﺓ‬


‫ﻳﺟﺏ ﻋﻠﻰ ﺍﻟﻣﻬﻧﺩﺱ ﺍﻹﺳﺗﺷﺎﺭﻱ ﺍﻟﺗﺄﻛﺩ ﻣﻥ ﺗﻭﻓﻳﺭ ﺍﻟﺷﺭﻭﻁ ﺍﻟﺿﺭﻭﺭﻳﺔ ﻟﻠﺣﺩ ﻣﻥ‬
‫ﺍﻟﺗﺄﺛﻳﺭﺍﺕ ﺍﻟﺑﻳﺋﺔ ﺍﻟﺿﺎﺭﺓ ﺧﻼﻝ ﻣﺭﺍﺣﻝ ﺗﻧﻔﻳﺫ ﺍﻷﻋﻣﺎﻝ ﻓﻲ ﺍﻟﻣﻭﻗﻊ ﻣﻥ ﺣﻳﺙ‪:‬‬
‫• ﺍﻟﺗﻘﻳﺩ ﺑﻣﻭﺍﻋﻳﺩ ﺍﻟﻌﻣﻝ ﻁﺑﻘﺎ ﻟﻣﺎ ﺗﺣﺩﺩﻩ ﺍﻟﺟﻬﺎﺕ ﺍﻟﻣﺧﺗﺻﺔ‪.‬‬
‫• ﻻ ﻳﺳﻣﺢ ﺑﺎﻟﻌﻣﻝ ﻓﻲ ﺍﻟﻣﻭﺍﻗﻊ ﺍﻹﻧﺷﺎءﺍﺕ ﺑﻌﺩ ﺍﻟﺳﺎﻋﺔ ﺍﻟﺛﺎﻣﻧﺔ ﻣﺳﺎءﺍ ﻭﻻ‬
‫ﻳﺳﻣﺢ ﺑﻣﺑﺎﺷﺭﺓ ﺍﻟﻌﻣﻝ ﻗﺑﻝ ﺍﻟﺳﺎﻋﺔ ﺍﻟﺳﺎﺩﺳﺔ ﺻﺑﺎﺣﺎ ﻓﻲ ﺍﻟﻣﻧﺎﻁﻖ‬
‫ﺍﻟﻣﺄﻫﻭﻟﺔ ‪ ،‬ﻭﻳﺟﻭﺯ ﻟﻺﺩﺍﺭﺓ ﺍﻟﻣﻌﻧﻳﺔ ﻣﻧﺢ ﺗﺻﺎﺭﻳﺢ ﺑﺗﺟﺎﻭﺯ ﻫﺫﻩ ﺍﻟﻣﺩﺓ ﺇﺫﺍ‬
‫ﻛﺎﻧﺕ ﻫﻧﺎﻙ ﺃﺳﺑﺎﺏ ﺗﺳﺗﺩﻋﻰ ﺫﻟﻙ ﻣﻊ ﻣﺭﺍﻋﺎﺓ ﻗﻭﺍﻧﻳﻥ ﻭﺯﺍﺭﺓﺍﻟﻌﻣﻝ‪.‬‬
‫• ﺇﺗﺧﺎﺫ ﺍﻟﻭﺳﺎﺋﻝ ﺍﻟﻼﺯﻣﺔ ﻭﺍﻟﺿﺭﻭﺭﻳﺔ ﻟﻠﺣﺩ ﻣﻥ ﻣﺳﺗﻭﻯ ﺍﻟﺿﺟﻳﺞ ﺍﻟﻧﺎﺗﺞ‬
‫ﻋﻥ ﺍﻟﻣﻌﺩﺍﺕ ﻭﺍﻵﻻﺕ ﺍﻟﻌﺎﻣﻠﺔ ﻓﻲ ﺍﻟﻣﻭﻗﻊ ﻭﺍﻟﺗﻘﻳﺩ ﺑﺎﻟﻣﺳﺗﻭﻯ ﺍﻟﺻﻭﺗﻲ‬
‫ﺍﻟﻣﺻﺭﺡ ﺑﻪ‪.‬‬
‫• ﺇﺗﺧﺎﺫ ﺍﻟﻭﺳﺎﺋﻝ ﺍﻟﻼﺯﻣﺔ ﻭﺍﻟﺿﺭﻭﺭﻳﺔ ﻟﻠﺣﺩ ﻣﻥ ﺇﻧﺑﻌﺎﺙ ﺍﻟﻐﺑﺎﺭ ﻭﺍﻷﺗﺭﺑﺔ‬
‫ﻭﺫﻟﻙ ﻣﻥ ﺧﻼﻝ ﺍﻟﻭﺳﺎﺋﻝ ﺍﻟﺗﺎﻟﻳﺔ‪:-‬‬
‫• ﺭﺵ ﺍﻷﺗﺭﺑﺔ ﻭﺍﻟﻣﻭﺍﻗﻊ ﺑﺎﻟﻣﺎء ﻋﻧﺩﻣﺎ ﺗﻛﻭﻥ ﻣﻌﺭﺿﺔ ﻹﺛﺎﺭﺓ ﺍﻟﻐﺑﺎﺭ‪.‬‬
‫• ﺗﻐﻁﻳﺔ ﻣﺩﺍﺧﻝ ﻭﺃﻣﺎﻛﻥ ﺣﺭﻛﺔ ﺍﻟﺳﻳﺎﺭﺍﺕ ﺑﻣﻭﺍﺩ ﻣﻧﺎﺳﺑﺔ ﺃﻭ ﺭﺷﻬﺎ ﺍﻟﻣﺳﺗﻣﺭ‬
‫ﺑﺎﻟﻣﺎء ﻟﻣﻧﻊ ﺍﻧﺑﻌﺎﺙ ﺍﻟﻐﺑﺎﺭ‪.‬‬
‫• ﻣﻧﻊ ﺇﻟﻘﺎء ﺍﻷﻧﻘﺎﺽ ﻣﻥ ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻌﻠﻳﺎ ﻣﺑﺎﺷﺭﺓ ﺩﻭﻥ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﺣﻭﺍﺟﺯ‬
‫ﺍﻟﻭﺍﻗﻳﺔ‪.‬‬
‫• ﺇﺗﺧﺎﺫ ﺍﻹﺣﺗﻳﺎﻁﺎﺕ ﺍﻟﺿﺭﻭﺭﻳﺔ ﺃﺛﻧﺎء ﻧﻘﻝ ﻭﺗﻔﺭﻳﻎ ﻣﻭﺍﺩ ﺍﻟﺑﻧﺎء‪.‬‬
‫ﺇﺗﺧﺎﺫ ﺍﻟﻭﺳﺎﺋﻝ ﺍﻟﻼﺯﻣﺔ ﻭﺍﻟﺿﺭﻭﺭﻳﺔ ﻟﻠﺣﺩ ﻣﻥ ﺇﻧﺑﻌﺎﺙ ﺍﻟﻐﺎﺯﺍﺕ ﻭﺍﻟﺩﺧﺎﻥ‬ ‫•‬
‫ﺍﻟﻧﺎﺗﺞ ﻣﻥ ﺍﻟﻣﻌﺩﺍﺕ ﻭﺍﻻﻵﺕ ﺍﻟﻣﺳﺗﺧﺩﻣﺔ ﻓﻲ ﻣﻭﺍﻗﻊ ﺍﻟﻌﻣﻝ ﻟﻠﻣﺣﺎﻓﻅﺔ‬
‫ﻋﻠﻳﻬﺎ ﻓﻲ ﺍﻟﻣﺳﺗﻭﻯ ﺍﻟﻣﺻﺭﺡ ﺑﻪ‪.‬‬
‫ﺇﺗﺧﺎﺫ ﺍﻹﺣﺗﻳﺎﻁﺎﺕ ﺍﻟﻼﺯﻣﺔ ﻓﻲ ﻣﻭﺍﻗﻊ ﺍﻟﻌﻣﻝ ﻟﻠﻣﺣﺎﻓﻅﺔ ﻋﻠﻰ ﻧﻅﺎﻓﺔ ﺍﻟﻣﻭﻗﻊ‬ ‫•‬
‫ﻭﺳﻼﻣﺔ ﺍﻟﺑﻳﺋﺔ ﺍﻟﻣﺣﻳﻁﺔ ﺑﻪ ﻣﻥ ﻣﺑﺎﻥ ﻣﺟﺎﻭﺭﺓ ﻭﺷﻭﺍﺭﻉ ﻭﺧﻁﻭﻁ ﺧﺩﻣﺎﺕ‬
‫ﻭﺃﺭﺻﻔﺔ ﻭﺯﺭﺍﻋﺔ‪...‬ﺇﻟﺦ‬
‫ﺃﻥ ﻳﺗﻡ ﺗﻭﺭﻳﺩ ﻭﺗﺧﺯﻳﻥ ﻣﻭﺍﺩ ﺍﻟﺑﻧﺎء ﻓﻲ ﺍﻟﻣﻭﻗﻊ ﺑﻣﺎ ﻳﺗﻧﺎﺳﺏ ﻣﻊ ﻣﺳﺎﺣﺗﻪ‬ ‫•‬
‫ﻭﺑﻣﺎ ﻻ ﻳﺷﻭﻩ ﺍﻟﻣﻧﻅﺭ ﺍﻟﻌﺎﻡ ﻣﻊ ﺿﺭﻭﺭﺓ ﺃﻥ ﻳﺗﻡ ﺗﺧﺯﻳﻥ ﺍﻟﻣﻭﺍﺩ ﺍﻟﺑﺗﺭﻭﻟﻳﺔ‬
‫ﻭﺍﻟﻛﻳﻣﻳﺎﺋﻳﺔ ﻓﻲ ﺃﻣﺎﻛﻥ ﻣﺣﺻﻭﺭﺓ ﻭﺑﻌﻳﺩﺓ ﻋﻥ ﺍﻟﺣﺭﻛﺔ ﺍﻟﻳﻭﻣﻳﺔ ﺍﻟﻣﺑﺎﺷﺭﺓ‬
‫ﻭﺃﻥ ﺗﻛﻭﻥ ﺗﺣﺕ ﺍﻟﺭﻗﺎﺑﺔ ﺍﻟﺩﺍﺋﻣﺔ ﻭﺑﻛﻣﻳﺎﺕ ﻗﻠﻳﻠﺔ‪.‬‬

‫ﺍﻟﻌﺯﻝ ﺍﻟﺣﺭﺍﺭﻱ‬
‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻔﻧﻳﺔ ﺍﻟﺗﺎﻟﻳﺔ ﺑﺧﺻﻭﺹ ﺍﻟﻌﺯﻝ ﺍﻟﺣﺭﺍﺭﻱ‪:-‬‬
‫ﺃﻥ ﻻ ﺗﺯﻳﺩ ﻗﻳﻣﺔ ﻣﻌﺎﻣﻝ ﺍﻹﻧﺗﻘﺎﻝ ﺍﻟﺣﺭﺍﺭﻱ )‪ (u‬ﻟﻸﺳﻁﺢ ﻭﺍﻟﺟﺩﺭﺍﻥ ﻛﻣﺎ‬ ‫•‬

‫ﺗﺷﻳﺭ ﺍﻟﻣﻘﺎﻳﻳﺱ ﺍﻟﻌﺎﻟﻣﻳﺔ ﻭﺍﻟﺗﻲ ﺗﻧﻁﺑﻖ ﻋﻠﻰ ﺍﻟﻣﻧﺎﺥ ﺍﻟﻣﺣﻳﻁ‪.‬‬


‫ﻳﺟﺏ ﺇﺳﺗﺧﺩﺍﻡ ﺍﻟﺯﺟﺎﺝ ﺑﺄﻧﻭﺍﻋﻪ ﺍﻟﻣﺧﺗﻠﻔﺔ ) ﺍﻟﻌﺎﺩﻱ ﻭﺍﻟﻣﺯﺩﻭﺝ ﻭﺍﻟﻌﺎﻛﺱ (‬ ‫•‬

‫ﻓﻲ ﺟﻣﻳﻊ ﻧﻭﺍﻓﺫ ﺍﻟﻣﺑﺎﻧﻲ ﺑﺎﺳﺗﻌﻣﺎﻻﺗﻬﺎ ﺍﻟﻣﺧﺗﻠﻔﺔ ﻁﺑﻘﺎ ﻟﻣﺎ ﺗﺣﺩﺩﻩ ﺍﺣﺗﻳﺎﺟﺎﺕ‬
‫ﺍﻟﻌﺯﻝ ﺍﻟﺣﺭﺍﺭﻱ‪.‬‬
‫ﻳﺟﺏ ﺗﺯﻭﻳﺩ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺗﻲ ﻳﺯﻳﺩ ﺇﺭﺗﻔﺎﻋﻬﺎ ﻋﻥ ﺃﺭﺿﻲ ﻭﻁﺎﺑﻖ ﻭﺍﺣﺩ‬ ‫•‬

‫ﻭﺗﺷﺗﻣﻝ ﻋﻠﻰ ﻣﺳﺎﺣﺎﺕ ﻛﺑﻳﺭﺓ ﻣﻥ ﺍﻟﺯﺟﺎﺝ ﻓﻲ ﺍﻟﻭﺍﺟﻬﺎﺕ ﺑﺎﻟﻣﻌﺩﺍﺕ‬


‫ﻭﺍﻷﺟﻬﺯﺓ ﺍﻟﻼﺯﻣﺔ ﻟﺗﻧﻅﻳﻑ ﺍﻟﺯﺟﺎﺝ ﻣﻥ ﺍﻟﺧﺎﺭﺝ ﻁﺑﻘﺎ ﻟﻣﺎ ﻳﻘﺭﺭﻩ ﻗﺳﻡ‬
‫ﺗﺭﺍﺧﻳﺹ ﺍﻟﻣﺑﺎﻧﻲ ﻓﻲ ﺍﻟﺑﻠﺩﻳﺔ‪.‬‬

‫ﺍﻟﺗﻣﺩﻳﺩﺍﺕ ﺍﻷﺭﺿﻳﺔ‬ ‫•‬

‫ﻋﻧﺩ ﺗﺻﻣﻳﻡ ﺷﺑﻛﺔ ﺍﻟﺗﻣﺩﻳﺩﺍﺕ ﺍﻷﺭﺿﻳﺔ ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺗﺎﻟﻲ‪:‬‬


‫ﺃﻥ ﺗﻛﻭﻥ ﺇﻧﺣﺩﺍﺭﺍﺕ ﺃﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ ﺑﻁﺭﻳﻘﺔ ﺍﻟﻧﻅﺎﻓﺔ ﺍﻟﺗﻠﻘﺎﺋﻳﺔ‪.‬‬ ‫•‬
‫ﺃﻥ ﻳﻛﻭﻥ ﺍﻹﻧﺣﺩﺍﺭ ﻷﻧﺎﺑﻳﺏ ﻗﻁﺭ‪ 100‬ﻣﻠﻡ – ‪ 1/60‬ﻗﻁﺭ ‪ 150‬ﻣﻠﻡ ‪1/90‬‬ ‫•‬
‫–ﻗﻁﺭ‪ 200‬ﻣﻠﻡ ‪ ، 1/120‬ﻭﻳﺣﻖ ﻟﻣﻬﻧﺩﺱ ﺍﻟﺑﻠﺩﻳﺔ ﺗﻌﺩﻳﻝ ﻫﺫﻩ ﺍﻟﻧﺳﺏ ﺇﺫﺍ‬
‫ﺍﻗﺗﺿﺕ ﺍﻟﺿﺭﻭﺭﺓ‪.‬‬
‫ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ ﺃﻧﺎﺑﻳﺏ ﺍﻟﺗﻣﺩﻳﺩﺍﺕ ﺍﻷﺭﺿﻳﺔ ﺍﻟﺭﺋﻳﺳﻳﺔ‪ 100‬ﻣﻠﻡ‪.‬‬ ‫•‬
‫ﺃﻥ ﺗﻛﻭﻥ ﺗﻣﺩﻳﺩﺍﺕ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﻣﺗﻧﺎﺳﻘﺔ ﻭﻣﺗﻭﺍﻓﻘﺔ ﻣﻊ ﺍﻷﺟﺯﺍء‬ ‫•‬
‫ﺍﻷﺧﺭﻯ ﻣﻥ ﺍﻟﺷﺑﻛﺔ ﺍﻟﺗﻲ ﺷﻳﺩﺕ ﺳﺎﺑﻘﺎ ﻭﺃﻥ ﺗﻛﻭﻥ ﻛﺎﻓﻳﺔ ﻟﻧﻘﻝ ﺟﻣﻳﻊ‬
‫ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﻧﺻﺭﻓﺔ ﻣﻥ ﺍﻟﻣﺑﻧﻰ ﺩﻭﻥ ﻋﻭﺍﺋﻖ ﺃﻭ ﺍﻟﺗﺳﺑﺏ ﻓﻲ ﺃﻱ ﺃﺿﺭﺍﺭ‪.‬‬
‫ﺃﻥ ﻳﺗﻡ ﻭﺿﻊ ﻏﺭﻓﺔ ﺗﻔﺗﻳﺵ ﺃﻭ ﻓﺗﺣﺔ ﺗﺳﻠﻳﻙ ﻋﻧﺩ ﻛﻝ ﺗﻐﻳﻳﺭ ﺇﺗﺟﺎﻩ‬ ‫•‬
‫ﻟﺧﻁﻭﻁ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺍﻹﻧﺣﺩﺍﺭﻳﺔ ﺃﻭ ﺍﻟﺗﻘﺎﻁﻊ ﺃﻭ ﺍﻟﺗﺟﻣﻳﻊ ﺃﻭ ﺍﻷﻧﺎﺑﻳﺏ‬
‫ﺍﻟﻣﻌﻠﻘﺔ‪.‬‬
‫ﻋﻧﺩ ﺗﻘﺎﻁﻊ ﺃﺳﺎﺳﺎﺕ ﺍﻟﻣﺑﺎﻧﻲ ﻣﻊ ﺧﻁﻭﻁ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﻳﺟﺏ ﺃﻥ ﺗﺭﻛﺯ‬ ‫•‬
‫ﺗﻠﻙ ﺍﻷﺳﺎﺳﻳﺎﺕ ﻋﻠﻰ ﻋﻣﻭﺩ ﻣﻥ ﺍﻟﺧﺭﺳﺎﻧﻪ ﺍﻟﻣﺳﻠﺣﺔ ﺃﻭ ﻋﻘﺩ ﻓﻭﻕ ﺧﻁ‬
‫ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﻭﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﻗﺭﺏ ﻧﻘﻁﺔ ﻟﻠﺗﺣﻣﻳﻝ ﻟﺫﻟﻙ ﺍﻟﻌﻣﻭﺩ ﺃﻭ‬
‫ﺍﻟﻌﻘﺩ ﻋﻠﻰ ﺑﻌﺩ ﺃﻓﻘﻲ ﻻ ﻳﻘﻝ ﻋﻥ ‪ 120‬ﺳﻡ ﻣﻥ ﺳﻁﺢ ﺍﻷﻧﺑﻭﺏ ﻭﺑﻁﺭﻳﻘﺔ‬
‫ﺗﻭﺍﻓﻖ ﻋﻠﻳﻬﺎ ﺍﻟﺳﻠﻁﺔ ﺍﻟﻣﺧﺗﺻﺔ‪.‬‬
‫ﻳﺗﻡ ﺗﻐﻠﻳﻑ ﺟﻣﻳﻊ ﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﺗﻲ ﺗﻣﺭ ﻋﺑﺭ ﺍﻟﻣﺑﺎﻧﻲ ﺑﺧﺭﺳﺎﻧﻪ ﻻ ﻳﻘﻝ ﺳﻣﻛﻬﺎ‬ ‫•‬
‫ﻋﻥ ‪ 15‬ﺳﻡ ﻣﻊ ﻭﺿﻊ ﻏﺭﻓﺔ ﺗﻔﺗﻳﺵ ﻋﻧﺩ ﺑﺩﺍﻳﺔ ﻭﻧﻬﺎﻳﺔ ﺍﻟﻌﺑﻭﺭ‪.‬‬
‫ﻋﻧﺩ ﺗﺟﻣﻳﻊ ﺧﻁﻭﻁ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﻓﻲ ﺍﻟﻣﻧﻭﺭ ﻳﺟﺏ ﺃﻥ ﻳﺗﺳﻊ ﺣﺟﻡ‬ ‫•‬
‫ﺍﻟﻣﻧﻭﺭ ﻟﻐﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﻭﺍﻟﻣﺣﺎﺑﺱ ﺍﻟﻣﺎﺋﻳﺔ ﻭﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﻌﻣﻭﺩﻳﺔ‬
‫ﻭﺍﻷﺭﺿﻳﺔ ﻭﺗﻣﺩﻳﺩﺍﺕ ﺍﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﻭﺃﻥ ﻳﺯﻭﺩ ﺍﻟﻣﻧﻭﺭ ﺑﻣﺩﺧﻝ ﻣﻧﺎﺳﺏ‬
‫ﻷﻋﻣﺎﻝ ﺍﻟﺻﻳﺎﻧﺔ ﻋﻠﻰ ﺇﺭﺗﻔﺎﻉ ‪ 50‬ﺳﻡ ﻣﻥ ﻣﻧﺳﻭﺏ ﺃﺭﺿﻳﺔ ﺍﻟﻣﻧﻭﺭ ﺃﻭ‬
‫ﺑﻁﺭﻳﻘﺔ ﺗﻭﺍﻓﻖ ﻋﻠﻳﻬﺎ ﺍﻟﺳﻠﻁﺔ ﺍﻟﻣﺧﺗﺻﺔ‪.‬‬
‫ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ ﺍﻧﺑﻭﺏ ﺍﻟﺗﺻﺭﻳﻑ ﻣﻥ ﺃﻱ ﻣﻧﻭﺭ ﺃﻭ ﻧﻘﺎﻁ ﺗﺟﻣﻳﻊ ﺇﻟﻰ‬ ‫•‬
‫ﺍﻟﺧﺎﺭﺝ ﻋﻥ‪ 150‬ﻣﻠﻡ‪.‬‬
‫ﻻ ﻳﺟﻭﺯ ﺭﺑﻁ ﺍﻟﺣﻣﺎﻣﺎﺕ ﻭﺍﻟﻣﻁﺎﺑﺦ ﺍﻟﺗﻲ ﺗﺷﻳﺩ ﺗﺣﺕ ﻣﺳﺗﻭﻯ ﺍﻟﻁﺎﺑﻖ‬ ‫•‬
‫ﺍﻷﺭﺿﻲ ﺑﺷﺑﻛﺔ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺍﻹﻧﺣﺩﺍﺭﻳﺔ ﺇﻻ ﺍﺫﺍ ﻛﺎﻧﺕ ﺃﻋﻠﻰ ﻣﻥ‬
‫ﻣﺳﺗﻭﻯ ﺳﻁﺢ ﺍﻟﺷﺎﺭﻉ ﺍﻟﺧﺎﺭﺟﻲ ﺃﻭ ﺑﻭﺍﺳﻁﺔ ﻣﺿﺧﺔ ﺭﺍﻓﻌﺔ‪.‬‬
‫ﺗﻐﻠﻳﻑ ﺃﻧﺎﺑﻳﺏ ﺍﻟﺗﻣﺩﻳﺩﺍﺕ ﺍﻷﺭﺿﻳﺔ ﺑﺎﻟﺧﺭﺳﺎﻧﺔ ﺑﺳﻣﻙ ﻻ ﻳﻘﻝ ﻋﻥ ‪150‬‬ ‫•‬
‫ﻣﻠﻡ ﻣﺗﻰ ﻣﺎ ﻛﺎﻥ ﻋﻣﻖ ﺍﻷﻧﺎﺑﻳﺏ ‪ 1‬ﺃﻗﻝ ﻣﻥ ‪ 120‬ﺳﻡ ﺃﻭ ﻋﻧﺩ ﻭﺿﻌﻬﺎ ﻓﻲ‬
‫ﺍﻟﻣﻣﺭﺍﺕ ﺃﻭ ﺍﻟﻁﺭﻗﺎﺕ‪.‬‬
‫ﻻ ﻳﺟﻭﺯ ﺗﻭﺻﻳﻝ ﺃﻛﺛﺭ ﻣﻥ ﺛﻼﺛﺔ ﻣﺭﺍﺣﻳﺽ ﻋﻠﻰ ﺧﻁ ﺃﻓﻘﻲ ﻭﺍﺣﺩ ﺇﻻ‬ ‫•‬
‫ﺑﻣﻭﺍﻓﻘﺔ ﺍﻟﺳﻠﻁﺔ ﺍﻟﻣﺧﺗﺻﺔ ﻋﻠﻰ ﺃﻥ ﻳﻛﻭﻥ ﻗﻁﺭ ﺍﻷﻧﺑﻭﺏ ﻓﻲ ﻫﺫﻩ ﺍﻟﺣﺎﻟﺔ‬
‫‪ 150‬ﻣﻠﻡ ﻣﻊ ﺗﺯﻭﻳﺩﻫﺎ ﺑﻔﺗﺣﺎﺕ ﺗﺳﻠﻳﻙ‪.‬‬
‫ﺗﺯﻭﻳﺩ ﺧﻁﻭﻁ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺍﻷﺭﺿﻳﺔ ﺑﺄﻧﺑﻭﺏ ﺗﻬﻭﻳﺔ ﻻ ﻳﻘﻝ ﻗﻁﺭﻫﺎ‬ ‫•‬
‫ﻋﻥ ‪ 100‬ﻣﻠﻡ ﻓﻲ ﺑﺩﺍﻳﺔ ﺍﻟﺧﻁﻭﻁ ﻭﺍﻟﻔﺭﻭﻉ ﺍﻟﺗﻲ ﻳﺯﻳﺩ ﻁﻭﻟﻬﺎ ﻋﻥ ‪6‬‬
‫ﺃﻣﺗﺎﺭ ﻋﻠﻰ ﺃﻥ ﻻ ﻳﻘﻝ ﻋﻥ‪ 90‬ﺳﻡ ﺇﺭﺗﻔﺎﻋﻬﺎ ﻣﻥ ﺃﻋﻠﻰ ﺳﻁﺢ ﺍﻟﻣﺑﻧﻰ‪.‬‬
‫ﻋﺩﻡ ﺍﻟﺳﻣﺎﺡ ﺑﺎﺳﺗﻌﻣﺎﻝ ﺗﻭﺻﻳﻼﺕ )‪ (T or Y‬ﺃﻭ ﻣﺎ ﻳﺷﺎﺑﻪ ﺫﻟﻙ ﻓﻲ‬ ‫•‬
‫ﺍﻟﺗﻣﺩﻳﺩﺍﺕ ﺍﻷﺭﺿﻳﺔ ﺇﻻ ﺑﻌﺩ ﻣﻭﺍﻓﻘﺔ ﺍﻟﺳﻠﻁﺔ ﺍﻟﻣﺧﺗﺻﺔ‪.‬‬
‫ﺃﻥ ﺗﻛﻭﻥ ﺍﻷﻧﺎﺑﻳﺏ ﻓﻲ ﺧﻁ ﻣﺳﺗﻘﻳﻡ ﻣﻥ ﺃﻱ ﺟﻬﺎﺯ ﺻﺣﻲ ﺣﺗﻰ ﺍﻟﻣﺣﺑﺱ‬ ‫•‬
‫ﺍﻟﻣﺎﺋﻲ ﺃﻭ ﻣﺣﺑﺱ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺃﻭ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ‪.‬‬
‫ﺗﻭﺻﻳﻝ ﺟﻣﻳﻊ ﺍﻷﺟﻬﺯﺓ ﺍﻟﺻﺣﻳﺔ ﺇﻟﻰ ﻣﺣﺑﺱ ﻣﺎﺋﻲ ﺟﺎﻣﻊ ﻗﺑﻝ ﺭﺑﻁﻬﺎ‬ ‫•‬
‫ﺑﻐﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ‪.‬‬
‫ﺗﻭﺻﻳﻝ ﺟﻣﻳﻊ ﺍﻟﻣﻁﺎﻋﻡ ﻭﺍﻟﻣﻁﺎﺑﺦ ﺍﻟﻛﺑﻳﺭﺓ ﺇﻟﻰ ﻣﺻﻳﺩﺓ ﺩﻫﻭﻥ ﻗﺑﻝ‬ ‫•‬
‫ﺭﺑﻁﻬﺎ ﺑﻐﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ‪.‬‬
‫ﺗﻭﺻﻳﻝ ﺩﻭﺭﺍﺕ ﺍﻟﻣﻳﺎﻩ ﻣﺑﺎﺷﺭﺓ ﺇﻟﻰ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ‪.‬‬ ‫•‬
‫ﺗﺯﻭﻳﺩ ﻛﺎﻓﺔ ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﺗﺣﺗﻳﺔ )ﺍﻟﺳﺭﺍﺩﻳﺏ( ﺑﺎﻟﻭﺳﺎﺋﻝ ﻭﺍﻟﻣﻌﺩﺍﺕ ﺍﻟﻣﻧﺎﺳﺑﺔ‬ ‫•‬
‫ﻟﺻﺭﻑ ﻭﺗﻧﻘﻳﺔ ﺍﻟﻣﻳﺎﻩ ﻣﺛﻝ )ﻏﺭﻑ ﺗﺭﺳﻳﺏ ﺍﻟﺭﻣﺎﻝ ‪-‬ﺍﻟﻣﺿﺧﺎﺕ – ﻣﺻﺎﺋﺩ‬
‫ﺍﻟﺷﺣﻭﻡ ‪...‬ﺇﻟﺦ(‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺻﺭﻑ ﻛﻣﻳﺎﺕ ﻛﺑﻳﺭﺓ ﻣﻥ ﺍﻟﺷﺣﻭﻡ ﻭﺍﻟﺯﻳﻭﺕ ﺇﻟﻰ ﺷﺑﻛﺔ ﺍﻟﺻﺭﻑ‬ ‫•‬
‫ﺍﻟﺻﺣﻲ ﻣﻥ ﺍﻟﻣﻁﺎﻋﻡ ﺃﻭ ﺍﻟﻣﻁﺎﺑﺦ ﺃﻭ ﺍﻷﺑﻧﻳﺔ ﺍﻟﺗﻲ ﻳﺯﻳﺩ ﻋﺩﺩ ﺍﻟﻣﻁﺎﺑﺦ ﻓﻳﻬﺎ‬
‫ﻋﻥ )‪ (50‬ﻣﻁﺑﺦ ﻭﻣﺎﻓﻲ ﺣﻛﻣﻬﺎ‪ ،‬ﻭﻳﺟﺏ ﺗﺭﻛﻳﺏ ﻣﺣﺑﺱ ﻟﻠﺷﺣﻭﻡ ﻭﺍﻟﺯﻳﻭﺕ‬
‫ﺫﻭ ﺗﺻﻣﻳﻡ ﻣﻌﺗﻣﺩ ﻣﻥ ﺍﻹﺩﺍﺭﺓ ﺍﻟﻣﻌﻧﻳﺔ‪.‬‬
‫ﺗﺄﻣﻳﻥ ﻣﺻﺭﻑ ﻓﻲ )ﻏﺭﻓﺔ ﺍﻟﻧﻔﺎﻳﺎﺕ ‪ ،‬ﻏﺭﻓﺔ ﺍﻟﻣﺿﺧﺎﺕ ‪ ،‬ﻏﺭﻓﺔ ﺗﺟﻔﻳﻑ‬ ‫•‬
‫ﺍﻟﻣﻼﺑﺱ‪ ،‬ﺍﻟﻣﻧﺎﻭﺭ‪ ،‬ﺍﻟﺷﺭﻓﺎﺕ(‪.‬‬

‫ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ‬ ‫•‬


‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺗﺎﻟﻲ‪:-‬‬
‫ﺃﻥ ﺗﻛﻭﻥ ﺃﺭﺿﻳﺎﺕ ﻏﺭﻑ ﺍﻟﺗﻔﺗﻳﺵ ﻋﻠﻰ ﺧﺭﺳﺎﻧﺔ ﻻ ﻳﻘﻝ ﺳﻣﻛﻬﺎ ﻋﻥ ‪25‬‬ ‫•‬
‫ﺳﻡ ﻭﺑﺭﻭﺯ ‪ 25‬ﺳﻡ ﻋﻥ ﺟﺩﺭﺍﻥ ﺍﻟﻐﺭﻓﺔ‪.‬‬
‫ﻋﻧﺩ ﺗﺷﻳﻳﺩ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﻓﻭﻕ ﻣﺳﺗﻭﻯ ﺍﻟﻣﻳﺎﻩ ﻳﺟﺏ ﺗﺷﻳﺩﻫﺎ ﺑﺈﺳﺗﻌﻣﺎﻝ‬ ‫•‬
‫ﺍﻟﻁﺎﺑﻭﻕ ﺩﻫﻧﻬﺎ ﺑﻁﺑﻘﺗﻳﻥ ﻣﻥ ﺍﻟﻣﻭﺍﺩ ﺍﻟﻌﺎﺯﻟﺔ ﻟﻠﺭﻁﻭﺑﺔ‪.‬‬
‫ﻋﻧﺩ ﺗﺷﻳﻳﺩ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﺗﺣﺕ ﻣﺳﺗﻭﻯ ﺍﻟﻣﻳﺎﻩ ﺍﻟﺳﻁﺣﻳﺔ ﻳﺟﺏ‬ ‫•‬
‫ﺗﺷﻳﺩﻫﺎ ﺑﺎﻟﺧﺭﺳﺎﻧﺔ ﺍﻟﻣﺳﻠﺣﺔ ﻋﻠﻰ ﺇﻻ ﻳﻘﻝ ﺳﻣﻙ ﺍﻟﺟﺩﺭﺍﻥ ﻋﻥ ‪ 20‬ﺳﻡ‬
‫ﻣﻥ ﺍﻟﺩﺍﺧﻝ ﻭﺍﻟﺧﺎﺭﺝ ﻭﺩﻫﻧﻬﺎ ﺑﻁﺑﻘﺗﻳﻥ ﻣﻥ ﺍﻟﻣﻭﺍﺩ ﺍﻟﻌﺎﺯﻟﺔ ﻟﻠﺭﻁﻭﺑﺔ‪.‬‬
‫ﺗﻛﻭﻥ ﺍﻟﻣﻭﺍﺩ ﺍﻟﻣﺳﺗﻌﻣﻠﺔ ﻛﺎﻟﺭﻣﻝ ﻭﺍﻟﺧﺭﺳﺎﻧﺔ ﻭﺍﻟﻣﻳﺎﻩ ﺧﺎﻟﻳﺔ ﻣﻥ ﺍﻷﺗﺭﺑﺔ‬ ‫•‬
‫ﻭﺍﻷﻣﻼﺡ ﻣﻊ ﺇﺳﺗﻌﻣﺎﻝ ﺍﻷﺳﻣﻧﺕ ﺍﻟﻣﻘﺎﻭﻡ ﻟﻸﻣﻼﺡ‪.‬‬
‫ﻳﺗﻡ ﺗﺷﻳﻳﺩ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﺍﻟﻌﻣﻳﻘﺔ ﺍﻟﺗﻲ ﺗﻘﻊ ﺗﺣﺕ ﻣﻧﺳﻭﺏ ﺍﻟﻣﻳﺎﻩ‬ ‫•‬
‫ﺍﻟﺳﻁﺣﻳﺔ ﻋﻠﻰ ﺃﺭﺿﻳﺎﺕ ﺟﺎﻓﺔ ﺗﻣﺎﻣﺎ‪.‬‬
‫ﺗﺻﺏ ﺍﻟﺧﺭﺳﺎﻧﻪ ﺍﻟﻣﺳﻠﺣﺔ ﻟﻐﺭﻑ ﺍﻟﺗﻔﺗﻳﺵ ﺍﻟﻌﻣﻳﻘﺔ ﻋﻠﻰ ﻗﻭﺍﻟﺏ ﻣﻥ‬ ‫•‬
‫ﻣﺎﺩﺓ ﺍﻷﻟﻳﺎﻑ ﺍﻟﺯﺟﺎﺟﻳﺔ‪.‬‬
‫ﻳﺷﺗﺭﻁ ﻋﻣﻝ ﻏﺭﻑ ﺗﻔﺗﻳﺵ ﺫﺍﺕ ﻏﻁﺎء ﻣﺣﻛﻡ ﻓﻲ ﺃﻱ ﻧﻘﻁﺔ ﻳﺗﻐﻳﺭ ﻓﻳﻬﺎ‬ ‫•‬
‫ﺍﻹﺗﺟﺎﻩ ﻋﻠﻰ ﺃﻥ ﻻ ﻳﺯﻳﺩ ﺍﻟﺑﻌﺩ ﺑﻳﻥ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﻭﺃﺧﺭﻯ ﻋﻥ ‪ 15‬ﻣﺗﺭﺍ‬
‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﺗﻣﺩﻳﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﻻ ﻳﺯﻳﺩ ﻋﻥ ‪ 30‬ﻣﺗﺭﺍ ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﺗﻣﺩﻳﺩﺍﺕ‬
‫ﺍﻟﻔﺭﻋﻳﺔ‪.‬‬
‫ﺃﻥ ﺗﺗﻧﺎﺳﺏ ﻣﻘﺎﺳﺎﺕ ﻏﺭﻑ ﺍﻟﺗﻔﺗﻳﺱ ﻣﻊ ﺍﻟﻌﻣﻖ ﻭﻋﺩﺩ ﺍﻟﻔﺭﻭﻉ ﺍﻟﻣﻭﺻﻠﺔ‬ ‫•‬
‫ﺇﻟﻳﻬﺎ ﻋﻠﻰ ﺃﻥ ﻻ ﻳﻘﻝ ﺃﺑﻌﺎﺩﻫﺎ ﻋﻥ ﺑﻳﺎﻧﺎﺕ ﺍﻟﺟﺩﻭﻝ ﺃﺩﻧﺎﻩ‪:‬‬
‫‪60×60‬ﺳﻡ‬ ‫ﻋﻣﻖ ﻣﻥ ‪ 50‬ﺳﻡ ﺍﻟﻰ ‪ 100‬ﺳﻡ‬
‫‪100×90‬ﺳﻡ‬ ‫ﻋﻣﻖ ﻣﻥ ‪ 100‬ﺳﻡ ﺇﻟﻰ ‪ 150‬ﺳﻡ‬
‫‪120×90‬ﺳﻡ‬ ‫ﻋﻣﻖ ﻣﻥ ‪ 150‬ﺳﻡ ﺇﻟﻰ‪ 200‬ﺳﻡ‬
‫‪150×150‬ﺳﻡ‬ ‫ﻋﻣﻖ ﺃﻛﺛﺭ ﻣﻥ‪ 200‬ﺳﻡ‬
‫ﺗﻘﻁﻳﻊ ﺍﻟﻘﻧﻭﺍﺕ ﺩﺍﺧﻝ ﻏﺭﻑ ﺍﻟﺗﻔﺗﻳﺵ ﺑﻁﺭﻳﻘﺔ ﺻﺣﻳﺣﺔ ﻭﺳﻠﻳﻣﺔ‬ ‫•‬
‫ﻭﺑﺎﻟﻛﻳﻔﻳﺔ ﺍﻟﺗﻲ ﺗﻣﻧﻊ ﺗﺭﺳﺏ ﺍﻟﻣﻭﺍﺩ ﺍﻟﻌﺿﻭﻳﺔ ﻭﺧﻼﻓﻬﺎ ﺩﺍﺧﻝ ﻏﺭﻑ‬
‫ﺍﻟﺗﻔﺗﻳﺵ ﻭﺃﻥ ﺗﻛﻭﻥ ﻓﺗﺣﺔ ﺍﻟﻘﻧﻭﺍﺕ ﻣﺗﺳﺎﻭﻳﺔ ﻭﺍﻥ ﺗﻛﻭﻥ ﺍﻟﻘﻧﻭﺍﺕ ﺍﻟﻔﺭﻋﻳﺔ‬
‫ﺃﻋﻠﻰ ﻣﻥ ﺍﻟﻘﻧﺎﺓ ﺍﻟﺭﺋﻳﺳﺔ ﺑﻣﺎ ﻻ ﻳﻘﻝ ﻋﻥ ‪ 5‬ﺳﻡ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﻓﺭﻕ ﺑﻳﻥ ﻗﺎﻉ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﺍﻟﺭﺋﻳﺳﻳﺔ ﻭﻣﻧﺳﻭﺏ‬ ‫•‬
‫ﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﻣﻭﺻﻠﺔ ﺇﻟﻳﻪ ﻳﺟﻭﺯ ﻋﻣﻝ ﺇﻧﺣﺩﺍﺭ ﺧﺭﺳﺎﻧﻲ ﺩﺍﺧﻝ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ‬
‫ﻋﻠﻰ ﺃﻥ ﻻ ﻳﺯﻳﺩ ﺇﺭﺗﻔﺎﻉ ﺍﻹﻧﺣﺩﺍﺭ ﻋﻥ‪ 60‬ﺳﻡ ﻭﻳﺟﺏ ﺃﻥ ﻳﻛﻭﻥ ﻣﻘﻭﺱ‬
‫ﺑﻁﺭﻳﻘﺔ ﻻ ﺗﻌﻳﻖ ﺇﻧﺳﻳﺎﺏ ﺍﻟﻣﻭﺍﺩ ﺍﻟﻌﺿﻭﻳﺔ ﻭﺍﻟﺳﻭﺍﺋﻝ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﺗﻲ ﻳﻛﻭﻥ ﻣﻧﺳﻭﺑﻬﺎ ﺃﻋﻠﻰ ﻣﻥ ﻗﺎﻉ ﺍﻟﻣﻧﻬﻭﻝ ﺑﺄﻛﺛﺭ ﻣﻥ‬ ‫•‬
‫‪60‬ﺳﻡ ﻳﻣﻛﻥ ﻋﻣﻝ ﻭﺻﻠﺔ ﻋﻣﻭﺩﻳﺔ ﺧﺎﺭﺝ ﺃﻭ ﺩﺍﺧﻝ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ‪/‬‬
‫ﺍﻟﻣﺎﻧﻬﻭﻝ‬
‫)‪(Back/Internal Drop‬ﻋﻠﻰ ﺃﻥ ﺗﻐﻠﻑ ﺑﺎﻟﺧﺭﺳﺎﻧﺔ ﻓﻲ ﺣﺎﻟﺔ‬
‫ﺗﺷﻳﺩﻫﺎ ﻣﻥ ﺍﻟﺧﺎﺭﺝ‪.‬‬
‫ﺗﺷﻳﻳﺩ ﻏﺭﻓﺔ ﺗﻔﺗﻳﺵ ﻋﻠﻰ ﻛﻝ ﻣﺣﺑﺱ ﻣﺎﺋﻲ ﺟﺎﻣﻊ )‪(GT‬ﺑﻘﻳﺎﺱ ‪30×30‬‬ ‫•‬

‫ﺳﻡ ﻭﺗﻐﻁﻳﺗﻬﺎ ﺑﻐﻁﺎء ﻻ ﻳﻘﻝ ﻭﺯﻧﻪ ﻋﻥ ‪ 14‬ﻛﻳﻠﻭ ﻏﺭﺍﻡ ﻭﻋﻣﻖ ﻻ ﻳﺯﻳﺩ‬


‫ﻋﻥ‪ 30‬ﺳﻡ‪.‬‬
‫ﺃﻥ ﻳﻛﻭﻥ ﻏﻁﺎء ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﺍﻟﺗﻲ ﻳﻘﻝ ﻋﻣﻘﻬﺎ ﻋﻥ ﻭﺍﺣﺩ ﻣﺗﺭ ﺑﻧﻔﺱ‬ ‫•‬
‫ﻣﻘﺎﺳﺎﺕ ﺃﺑﻌﺎﺩ ﻏﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﻭﻳﻣﻛﻥ ﺗﺭﻛﻳﺏ ﺃﻛﺛﺭ ﻣﻥ ﻏﻁﺎء‪.‬‬
‫ﺇﻧﺷﺎء ﺟﻣﻳﻊ ﻏﺭﻑ ﺍﻟﺗﻔﺗﻳﺵ ﺩﺍﺧﻝ ﺣﺩﻭﺩ ﻗﻁﻌﺔ ﺍﻷﺭﺽ ﻭﻳﺟﺏ ﺃﻥ ﻳﺭﺍﻋﻲ‬ ‫•‬
‫ﻋﻧﺩ ﺍﻟﺗﺻﻣﻳﻡ ﻭﺗﺣﺩﻳﺩ ﻣﻭﺍﻗﻊ ﻏﺭﻑ ﺍﻟﺗﻔﺗﻳﺵ ‪ ،‬ﺇﺧﺗﻳﺎﺭ ﺍﻟﻣﻭﻗﻊ ﻭﺍﻟﻣﻧﺎﺳﻳﺏ‬
‫ﺍﻟﻣﻧﺎﺳﺑﺔ ﻟﻐﺭﻓﺔ ﺍﻟﺗﻔﺗﻳﺵ ﺍﻷﺧﻳﺭﺓ ﻣﻥ ﺣﻳﺙ ﺳﻬﻭﻟﺔ ﺍﻟﺗﻭﺻﻳﻝ ﺑﺷﺑﻛﺔ‬
‫ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺍﻟﻌﺎﻣﺔ ﻭﺗﺣﻘﻳﻘﻬﺎ ﻟﺷﺭﻭﻁ ﺍﻹﺩﺍﺭﺓ ﺍﻟﻣﻌﻳﻧﺔ‪.‬‬
‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺃﻥ ﺗﻛﻭﻥ ﺍﻷﻏﻁﻳﺔ ﺍﻟﻣﺳﺗﺧﺩﻣﺔ ﻹﻏﻼﻕ ﻏﺭﻑ ﺍﻟﺗﻔﺗﻳﺵ ﻣﻥ‬ ‫•‬
‫ﺍﻟﻧﻭﻉ ﺍﻟﺛﻘﻳﻝ ﻭﺃﻥ ﻳﺳﻬﻝ ﻓﺗﺣﻪ ﻭﺇﻏﻼﻗﻪ ﻷﻋﻣﺎﻝ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﺿﺭﻭﺭﻳﺔ‪.‬‬
‫ﺍﻟﻧﻭﻉ ﺍﻟﺛﻘﻳﻝ ﻭﺃﻥ ﺳﻬﻝ ﻓﺗﺣﻪ ﻭﺇﻏﻼﻗﻪ ﻷﻋﻣﺎﻝ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﺿﺭﻭﺭﻳﺔ‪.‬‬ ‫•‬

‫ﺧﺯﺍﻧﺎﺕ ﺍﻟﺗﺣﻠﻳﻝ ﻭﺍﻟﺗﺻﺭﻳﻑ‬ ‫•‬


‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺗﺎﻟﻲ ﻋﻧﺩ ﺇﻧﺷﺎء ﺧﺯﺍﻥ ﺍﻟﺗﺣﻠﻳﻝ ﻭﺍﻟﺻﺭﻑ‪:-‬‬
‫ﺃﻥ ﺗﻛﻭﻥ ﺿﻣﻥ ﺣﺩﻭﺩ ﻗﻁﻌﺔ ﺍﻷﺭﺽ‪.‬‬ ‫•‬
‫• ﺃﻥ ﺗﻛﻭﻥ ﻓﻲ ﻣﻭﻗﻊ ﻗﺭﻳﺏ ﻣﻥ ﺍﻟﻁﺭﻳﻖ ﺃﻭ ﺍﻟﺳﻛﺔ ﻭﺑﻌﻳﺩﺓ ﻋﻥ ﺍﻟﻣﺑﻧﻰ‬
‫ﺍﻟﺭﺋﻳﺳﻲ ﻭﺍﻟﺟﻭﺍﺭ ﻭﻳﺳﻬﻝ ﺍﻟﻭﺻﻭﻝ ﺇﻟﻳﻬﺎ ﻟﻠﺗﻧﻅﻳﻑ ﻭﺍﻟﺻﻳﺎﻧﺔ ﻭﺍﻟﺗﻔﺭﻳﻎ‬
‫ﻋﻠﻰ ﺃﻥ ﺗﻛﻭﻥ ﺳﻬﻠﺔ ﺍﻟﺗﻭﺻﻳﻝ ﺑﺷﺑﻛﺔ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺍﻟﻌﺎﻣﺔ ﻣﺳﺗﻘﺑﻼ‪.‬‬
‫• ﺃﻥ ﺗﻛﻭﻥ ﺍﻟﺧﺯﺍﻧﺎﺕ ﻣﻥ ﺍﻟﺧﺭﺳﺎﻧﺔ ﺍﻟﻣﺳﻠﺣﺔ ﺑﺣﻳﺙ ﺗﺗﺣﻣﻝ ﻣﺭﻭﺭ‬
‫ﺍﻟﺳﻳﺎﺭﺍﺕ ﻓﻭﻗﻬﺎ ﺇﺫﺍ ﺍﻗﺗﺿﺕ ﺍﻟﺿﺭﻭﺭﺓ ﺫﻟﻙ‪.‬‬
‫ﺃﻥ ﻳﻛﻭﻥ ﻟﻬﺎ ﻓﺗﺣﺔ ﺑﻐﻁﺎء ﻣﻥ ﺍﻟﻧﻭﻉ ﺍﻟﺛﻘﻳﻝ ﻳﻣﻛﻥ ﺇﺣﻛﺎﻡ ﻏﻠﻘﻪ‪ ،‬ﻭﺃﻥ‬ ‫•‬
‫ﺗﻛﻭﻥ ﺑﺄﺑﻌﺎﺩ ﻛﺎﻓﻳﻪ‪.‬‬
‫ﺃﻻ ﻳﺭﺗﻔﻊ ﻣﻧﺳﻭﺏ ﺳﻘﻔﻬﺎ ﻋﻥ ﻣﻧﺳﻭﺏ ﺃﺭﺿﻳﺔ ﺍﻟﻣﻭﻗﻊ ﺍﻟﻣﺗﻭﺍﺟﺩﺓ ﻓﻳﻪ‪.‬‬ ‫•‬
‫ﺃﻥ ﺗﻛﻭﻥ ﺳﻌﺔ ﻫﺫﻩ ﺍﻟﺧﺯﺍﻧﺎﺕ ﻣﻧﺎﺳﺑﺔ ﻭﻣﺣﺳﻭﺑﺔ ﻋﻠﻰ ﺃﺳﺎﺱ‬ ‫•‬
‫ﺍﻹﺳﺗﻬﻼﻙ ﺍﻟﺷﺧﺻﻲ ﺍﻟﻳﻭﻣﻲ ﺣﺳﺏ ﺍﻟﺟﺩﺍﻭﻝ ﺍﻟﻘﻳﺎﺳﻳﺔ‪.‬‬
‫•‬
‫ﺃﻥ ﺗﻛﻭﻥ ﻋﻠﻰ ﺑﻌﺩ ﻻ ﻳﻘﻝ ﻋﻥ )‪ (1‬ﻣﻥ ﺍﻟﻣﺑﺎﻧﻲ ﻭﺍﻷﺳﻭﺍﺭ ﺍﻟﻣﺟﺎﻭﺭﺓ ‪ ،‬ﺃﻥ‬ ‫•‬
‫ﻻ ﻳﻘﻝ ﻋﻣﻘﻬﺎ ﻋﻥ ﻣﺗﺭ ﻭﻧﺻﻑ ﻣﻥ ﻣﻧﺳﻭﺏ ﺃﺳﻔﻝ ﺃﻧﺑﻭﺏ ﻣﺩﺧﻝ ﺍﻟﺧﺯﺍﻥ‪.‬‬
‫ﻓﻲ ﺍﻟﻣﻧﺎﻁﻖ ﺍﻟﺗﻲ ﻳﻛﻭﻥ ﻓﻳﻬﺎ ﻣﻧﺳﻭﺏ ﺍﻟﻣﻳﺎﻩ ﺍﻟﺟﻭﻓﻳﺔ ﻣﺭﺗﻔﻌﺎ ﺃﻭ ﺃﻥ ﻣﻌﺩﻝ‬ ‫•‬
‫ﺗﺻﺭﻳﻑ ﺍﻟﻣﻳﺎﻩ ﻓﻳﻬﺎ ﻛﺎﻓﻲ ﻣﻥ ﺧﻼﻝ ﺍﻟﺗﺭﺑﺔ ‪ ،‬ﻓﻳﺟﺏ ﺃﻥ ﻳﺗﻡ ﻋﻣﻝ ﺧﺯﺍﻧﺎﺕ‬
‫ﻟﺗﺟﻣﻳﻊ ﻣﻳﺎﻩ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﻓﻳﻬﺎ ﻟﺣﻳﻥ ﻧﻘﻠﻬﺎ ﺇﻟﻰ ﻧﻘﺎﻁ ﺗﺣﺩﺩﻫﺎ‬
‫ﺍﻹﺩﺍﺭﺓ ﺍﻟﻣﺧﺗﺻﺔ‪.‬‬
‫ﺃﻥ ﻳﺗﻡ ﺗﺻﻣﻳﻡ ﺧﺯﺍﻥ ﺍﻟﺗﺣﻠﻝ ﻭﺍﻟﺗﺻﺭﻳﻑ ﻁﺑﻘﺎ ﻟﻠﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻘﻳﺎﺳﻳﺔ‬ ‫•‬
‫ﺍﻟﻣﺗﻌﻣﺩﺓ ﻭﺃﻥ ﻳﺯﻭﺩ ﺧﺯﺍﻥ ﺍﻟﺗﺣﻠﻝ ﺑﺄﻧﺑﻭﺏ ﺗﻬﻭﻳﺔ ﺣﺳﺏ ﺍﻟﺷﺭﻭﻁ ﺍﻹﺩﺍﺭﺓ‬
‫ﺍﻟﻣﺧﺗﺻﺔ‪ ،‬ﺃﻥ ﺗﻛﻭﻥ ﺟﻣﻳﻊ ﻓﺗﺣﺎﺗﻪ ﻣﻐﻁﺎﺓ ﺑﻁﺭﻳﻘﺔ ﺗﻣﻧﻊ ﺩﺧﻭﻝ ﻭﺧﺭﻭﺝ‬
‫ﺍﻟﺣﺷﺭﺍﺕ ﺇﻟﻳﻪ‪.‬‬
‫ﺑﺈﺳﺗﺛﻧﺎء ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺳﻛﻧﻳﺔ ﻳﺟﺏ ﺗﻭﻓﻳﺭ ﻣﺻﺎﺋﺩ ﻟﻠﺷﺣﻭﻡ ﻭﺍﻟﺯﻳﻭﺕ ﺍﻟﻧﺎﺗﺟﺔ‬ ‫•‬
‫ﻋﻥ ﺍﻟﻣﻁﺎﺑﺦ ﻭﻣﻧﺎﻁﻖ ﺗﺟﻬﻳﺯ ﺍﻟﻁﻌﺎﻡ ‪.‬‬

‫ﺍﻟﺗﻣﺩﻳﺩﺍﺕ ﺍﻟﻌﻣﻭﺩﻳﺔ‬ ‫•‬


‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺗﺎﻟﻲ ﻓﻲ ﺍﻟﺗﻣﺩﻳﺩﺍﺕ ﺍﻟﻌﻣﻭﺩﻳﺔ ﻟﻸﻋﻣﺎﻝ ﺍﻟﺻﺣﻳﺔ‪:‬‬
‫• ﻋﺩﻡ ﺟﻭﺍﺯ ﺗﻣﺩﻳﺩ ﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﻌﻣﻭﺩﻳﺔ ﺩﺍﺧﻝ ﺍﻟﺧﺭﺳﺎﻧﺎﺕ ﺃﻭ‬
‫ﺍﻟﺟﺩﺭﺍﻥ‪.‬‬
‫• ﺇﺳﺗﻌﻣﺎﻝ ﻧﻅﺎﻡ ﺍﻟﺻﺭﻑ ﻋﻠﻰ ﻋﻣﻭﺩﻳﻥ ﺃﺣﺩﻫﻣﺎ ﻟﻠﺻﺭﻑ ﺍﻟﺛﻘﻳﻝ‬
‫ﻭﺍﻟﺛﺎﻧﻲ ﻟﻠﺻﺭﻑ ﺍﻟﻌﺎﺩﻱ ﻓﻲ ﺍﻟﻣﺑﺎﻧﻲ ﺫﺍﺕ ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻣﺗﻌﺩﺩﺓ‬
‫ﻋﻣﻭﻣﺎ ﻣﻊ ﺗﺭﻛﻳﺏ ﺃﻧﺎﺑﻳﺏ ﺗﻬﻭﻳﺔ ﻟﻌﻣﻭﺩ ﺍﻟﺻﺭﻑ ﺍﻟﺛﻘﻳﻝ ﻭﺗﺭﻛﻳﺏ‬
‫ﺳﻳﻔﻭﻥ ﻟﻛﻝ ﺣﻣﺎﻡ‪.‬‬
‫• ﻳﻣﻛﻥ ﺇﺳﺗﻌﻣﺎﻝ ﻧﻅﺎﻡ ﺍﻟﻣﺎﺳﻭﺭﺓ ﺍﻟﻭﺍﺣﺩﺓ )ﺍﻟﻣﺷﺗﺭﻛﺔ( ﺷﺭﻳﻁﺔ‬
‫ﺗﺭﻛﻳﺏ ﻣﻭﺍﺳﻳﺭ ﻣﻧﻊ ﺍﻹﻣﺗﺻﺎﺹ )‪ (Antisy phonic‬ﻭﺫﻟﻙ‬
‫ﻟﻠﻣﺑﺎﻧﻲ ﺍﻷﻗﻝ ﻣﻥ ﺳﺗﺔ ﻁﻭﺍﺑﻖ ‪ ،‬ﻭﺃﻥ ﻳﺗﻧﺎﺳﺏ ﻗﻁﺭ ﺃﻧﺑﻭﺏ ﺍﻟﺻﺭﻑ‬
‫ﻣﻊ ﻛﻣﻳﺔ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﻧﺻﺭﻓﺔ ﻋﻠﻳﻪ‪.‬‬
‫• ﻳﻣﻛﻥ ﺇﺳﺗﻌﻣﺎﻝ ﻧﻅﺎﻡ ﺍﻟﺻﺭﻑ ﻋﻠﻰ ﻋﻣﻭﺩﻳﻥ ﻓﻲ ﺍﻟﻣﺑﺎﻧﻲ ﺫﺍﺕ‬
‫ﺍﻟﻣﺑﺎﻧﻲ ﻣﺗﻌﺩﺩﺓ ﺍﻟﻁﻭﺍﺑﻖ – ﺃﻛﺛﺭ ﻣﻥ ﺧﻣﺳﺔ ﻁﻭﺍﺑﻖ – ﻭﺃﻥ ﻻ ﻳﻘﻝ‬
‫ﻋﻣﻖ ﺍﻟﻣﺣﺎﺑﺱ ﺍﻟﻣﺎﺋﻳﺔ ﻓﻲ ﺟﻣﻳﻊ ﺍﻷﺟﻬﺯﺓ ﻋﻥ ‪ 75‬ﻣﻠﻡ ﻣﻊ ﻭﺟﻭﺏ‬
‫ﺗﺭﻛﻳﺏ ﺃﻧﺎﺑﻳﺏ ﺗﻬﻭﻳﺔ )‪.(Vent pipe‬‬
‫• ﺃﻻ ﻳﻘﻝ ﻗﻁﺭ ﻋﻣﻭﺩ ﺍﻟﺻﺭﻑ ﻋﻥ ‪ 75‬ﻣﻠﻡ ﻟﻛﻣﻳﺔ ﺍﻟﻣﻳﺎﻩ ﺑﺳﺭﻋﺔ‬
‫‪3‬ﻟﺗﺭ‪/‬ﺙ‪.‬‬
‫• ﺗﺛﺑﻳﺕ ﺃﻋﻣﺩﺓ ﺍﻟﺻﺭﻑ ﻭﺍﻟﻌﻣﻝ ﻭﺍﻟﺗﻬﻭﻳﺔ ﺑﺄﺭﺑﻁﺔ ﻣﻥ ﺍﻟﻧﻭﻉ ﺍﻟﺟﻳﺩ‬
‫ﺍﻟﻣﻘﺎﻭﻡ ﻟﻠﺻﺩﺃ‪ ،‬ﻭﻋﻠﻰ ﻣﺳﺎﻓﺎﺕ ﻻ ﺗﺯﻳﺩ ﻋﻥ ‪ 1.50‬ﻣﺗﺭ‪.‬‬
‫• ﺃﻻ ﻳﻘﻝ ﻗﻁﺭ ﻋﻣﻭﺩ ﺍﻟﺻﺭﻑ ﻋﻥ ‪ 75‬ﻣﻡ ﻟﻛﻣﻳﺔ ﻣﻳﺎﻩ ﺳﺭﻋﺗﻬﺎ ‪ 3‬ﻟﺗﺭ‬
‫‪/‬ﺛﺎﻧﻳﺔ‪.‬‬
‫• ﺃﻻ ﻳﻘﻝ ﻗﻁﺭ ﻋﻣﻭﺩ ﺍﻟﻌﻣﻝ ﻋﻥ ‪ 150‬ﻣﻠﻡ ﻟﻛﻣﻳﺔ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﻧﺻﺭﻓﺔ‬
‫ﺑﺳﺭﻋﺔ‪ 7‬ﻟﺗﺭ ‪/‬ﺛﺎﻧﻳﺔ‪ ،‬ﻭﻳﻣﻛﻥ ﺗﻌﺩﻳﻝ ﺍﻷﻗﻁﺎﺭ ﺣﺳﺏ ﺣﺟﻡ ﺍﻟﻣﺑﻧﻰ ﺃﻭ‬
‫ﻛﻣﻳﺔ ﻓﺭﻋﻳﺔ‪.‬‬
‫• ﺃﻥ ﺗﺯﻭﺩ ﺃﻋﻣﺩﺓ ﺍﻟﺻﺭﻑ ﺑﻔﺗﺣﺎﺕ ﺗﺳﻠﻳﻙ ﻋﻧﺩ ﻛﻝ ﺗﻭﺻﻳﻠﺔ ﻓﺭﻋﻳﺔ‪.‬‬
‫• ﻋﺩﻡ ﺍﻟﺳﻣﺎﺡ ﺑﺗﻭﺻﻳﻝ ﺃﻱ ﺃﺟﻬﺯﺓ ﺻﺣﻳﺔ ﺑﺎﻟﻁﺎﺑﻖ ﺍﻷﺭﺿﻲ ﺑﺄﻋﻣﺩﺓ‬
‫ﺍﻟﺻﺭﻑ ﺍﻟﻌﻣﻭﺩﻳﺔ ﺇﻻ ﺑﻌﺩ ﻣﻭﺍﻓﻘﺔ ﺍﻟﺳﻠﻁﺔ ﺍﻟﻣﺧﺗﺻﺔ‪.‬‬
‫• ﺗﺭﻛﻳﺏ ﻏﻁﺎء ﺷﺑﻙ ﻋﻠﻰ ﺭﺃﺱ ﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﻌﻣﻭﺩﻳﺔ‪.‬‬
‫• ﺗﺭﻛﻳﺏ ﻭﺻﻠﺔ ﺗﻣﺩﺩ ﻓﻲ ﺍﻷﻧﺎﺑﻳﺏ ﺍﻟﻌﻣﻭﺩﻳﺔ ﻣﺗﻰ ﺍﺳﺗﺩﻋﺕ‬
‫ﺍﻟﺿﺭﻭﺭﺓ ﻟﺫﻟﻙ ‪.‬‬
‫• ﺃﻋﻣﺩﺓ ﺍﻟﺻﺭﻑ ﻭﺍﻟﻌﻣﻝ ﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﺑﺎﺭﺯﺓ ﻋﻥ ﺳﻁﺢ ﺍﻟﻣﺑﻧﻰ‬
‫ﺍﻟﻌﻠﻭﻱ ﺑﻣﺎ ﻻ ﻳﻘﻝ ﻋﻥ ‪ 90‬ﺳﻡ‪.‬‬
‫• ﻓﺻﻝ ﺧﻁ ﺍﻟﻣﻁﺎﺑﺦ ﻋﻥ ﺧﻁ ﺻﺭﻑ ﺍﻟﺣﻣﺎﻣﺎﺕ ﻟﻠﻣﺑﺎﻧﻲ ﺍﻟﺗﻲ ﺗﺗﻁﻠﺏ‬
‫ﻭﺟﻭﺩ ﺻﺎﺋﺩ ﻟﻠﺷﺣﻭﻡ‪.‬‬
‫ﺻﺭﻑ ﻣﻳﺎﻩ ﺍﻷﻣﻁﺎﺭ‬ ‫•‬
‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﺗﺎﻟﻲ ﻟﺗﺄﻣﻳﻥ ﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ ﺍﻷﻣﻁﺎﺭ‬
‫• ﺗﺄﻣﻳﻥ ﻛﻝ ﺳﻁﺢ ﻣﻛﺷﻭﻑ ﺑﺄﻱ ﻣﺑﻧﻲ ﺑﻣﻳﻝ ﻻﺗﻘﻝ ﻧﺳﺑﺗﻪ ﻋﻥ‬
‫)‪1:50‬ﺣﺗﻰ‪ (1:70‬ﺑﺣﻳﺙ ﺗﻧﺳﺎﺏ ﺍﻟﻣﻳﺎﻩ ﻋﻠﻳﻪ ﺇﻟﻰ ﺃﻗﻧﻳﺔ ﻣﻧﺎﺳﺑﺔ ﺃﻭ‬
‫ﻣﺧﺎﺭﺝ ﺗﺅﺩﻱ ﺇﻟﻰ ﺃﻧﺎﺑﻳﺏ ﺻﺭﻑ ﺃﻭ ﺻﺭﻑ ﻣﺯﺍﺭﻳﺏ ﻣﻧﺎﺳﺑﺔ ﻟﻬﺫﺍ‬
‫ﺍﻟﻐﺭﺽ‪.‬‬
‫ﺃﻥ ﺗﻛﻭﻥ ﺍﻷﻗﻧﻳﺔ ﻭﺍﻟﻣﺯﺍ ﺭﻳﺏ ﻭﺍﻟﻣﺧﺎﺭﺝ ﻭﺃﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ ﺑﻣﻳﻝ ﻻ‬ ‫•‬
‫ﺗﻘﻝ ﺯﺍﻭﻳﺗﻪ ﻋﻥ)‪(1:90‬ﻭﻣﺻﻧﻭﻋﺔ ﻣﻥ ﻣﻭﺍﺩ ﻣﺗﻳﻧﺔ ﻭﻭﺻﻼﺕ‬
‫ﻣﺎﻧﻌﺔ ﻟﺗﺳﺭﺏ ﺍﻟﻣﻳﺎﻩ‪ ،‬ﺫﺍﺕ ﺃﺣﺟﺎﻡ ﻛﺎﻓﻳﺔ ‪ ،‬ﻭﻣﺛﺑﺗﻪ ﺑﺷﻛﻝ ﻗﻭﻱ‬
‫ﻭﺁﻣﻥ‪.‬‬
‫ﻋﺩﻡ ﺇﻣﻛﺎﻧﻳﺔ ﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ ﺍﻷﻣﻁﺎﺭ ﻓﻲ ﺃﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ ﺃﻭ‬ ‫•‬
‫ﻓﻲ ﺧﺯﺍﻧﺎﺕ ﺍﻟﺗﺣﻠﻝ ﺃﻭ ﺍﻟﺗﺻﺭﻳﻑ ﺇﻟﻰ ﺍﻟﺟﻭﺍﺭ ‪ ،‬ﻭﺍﻧﻣﺎ ﻳﻧﺑﻐﻲ‬
‫ﺗﺻﺭﻳﻔﻬﺎ ﺳﻁﺣﻳﺎ ﺇﻟﻰ ﺍﻟﺷﻭﺍﺭﻉ ﻭﺍﻟﺳﻛﻳﻙ ﻭﻳﺟﻭﺯ ﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ‬
‫ﺍﻷﻣﻁﺎﺭ ﻣﺑﺎﺷﺭﺓ ﺇﻟﻰ ﺍﻟﺷﺑﻛﺔ ﺍﻟﻌﺎﻣﺔ ﻟﺻﺭﻑ ﻣﻳﺎﻩ ﺍﻷﻣﻁﺎﺭ ﺃﻭ‬
‫ﺧﺯﺍﻧﺎﺕ ﺍﻟﺗﺻﺭﻳﻑ ﻭﺫﻟﻙ ﺑﺎﻟﺗﻧﺳﻳﻖ ﻣﻊ ﺍﻹﺩﺍﺭﺓ ﺍﻟﻣﻌﻧﻳﺔ‪.‬‬
‫ﻋﺩﻡ ﺇﻣﻛﺎﻧﻳﺔ ﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ ﺍﻟﻣﻛﻳﻔﺎﺕ ﻭﺍﻟﺷﺭﻓﺎﺕ ﻋﻠﻰ ﺍﻟﺷﻭﺍﺭﻉ‬ ‫•‬
‫ﺍﻟﻣﺑﺎﺷﺭﺓ ﺃﻭ ﺇﻟﻰ ﺧﻁﻭﻁ ﺻﺭﻑ ﻣﻳﺎﻩ ﺍﻷﻣﻁﺎﺭ ﻭﻳﺟﺏ ﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ‬
‫ﺍﻟﻣﻛﻳﻔﺎﺕ ﻭﺍﻟﺷﺭﻓﺎﺕ ﺇﻟﻰ ﺃﻣﺎﻛﻥ ﺷﺑﻛﺔ ﺍﻟﻣﺟﺎﺭﻱ ﺍﻟﻌﺎﻣﺔ‪.‬‬
‫ﻋﺩﻡ ﺇﻣﻛﺎﻧﻳﺔ ﺗﺻﺭﻳﻑ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻌﺎﻣﺔ ﺇﻟﻰ ﺷﺑﻛﺔ ﺗﺻﺭﻳﻑ ﻣﻳﺎﻩ‬ ‫•‬
‫ﺍﻷﻣﻁﺎﺭ ﺃﻳﺎ ﻛﺎﻧﺕ ﺍﻷﺳﺑﺎﺏ‪.‬‬
‫ﻧﻅﺎﻡ ﺻﺭﻑ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﻛﺛﻔﺔ ﻣﻥ ﺃﺟﻬﺯﺓ ﺍﻟﺗﻛﻳﻳﻑ‬ ‫•‬

‫ﻳﺭﺍﻋﻲ ﻋﻧﺩ ﺗﺻﻣﻳﻡ ﻧﻅﺎﻡ ﺻﺭﻑ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﻛﺛﻔﺔ ﻣﻥ ﺃﺟﻬﺯﺓ ﺍﻟﺗﻛﻳﻳﻑ ﺳﻭﺍء ﻛﺎﻧﺕ‬
‫ﻣﺭﻛﺯﻳﺔ ﺃﻭ ﻭﺣﺩﺍﺕ ﻣﺳﺗﻘﻠﺔ ﻣﺎﻳﻠﻲ‪:‬‬
‫• ﺃﻥ ﻳﻛﻭﻥ ﺍﻟﻧﻅﺎﻡ ﺑﺄﻧﺎﺑﻳﺏ ﻣﺳﺗﻘﻠﺔ ﻋﻥ ﺑﺎﻗﻲ ﺃﻧﻅﻣﺔ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ‪.‬‬
‫• ﺃﻥ ﺗﻛﻭﻥ ﺃﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ ﻏﻳﺭ ﻅﺎﻫﺭﺓ ﻣﻥ ﺍﻟﺧﺎﺭﺝ ﺃﻭ ﻣﻥ ﺍﻟﺩﺍﺧﻝ‪.‬‬
‫• ﺃﻥ ﺗﻛﻭﻥ ﺍﻷﻧﺎﺑﻳﺏ ﻣﺻﻧﻭﻋﺔ ﻣﻥ ﻣﺎﺩﺓ ﻣﺗﻳﻧﺔ ﻏﻳﺭ ﻗﺎﺑﻠﺔ ﻟﻠﺻﺩﺃ ﻭﻏﻳﺭ‬
‫ﻣﺭﻧﺔ‪.‬‬
‫• ﺃﻥ ﻳﻛﻭﻥ ﺍﻟﻘﻁﺭ ﺍﻟﺩﺍﺧﻠﻲ ﻷﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ ﺍﻟﻔﺭﻋﻳﺔ ‪ 2/1 – 4/3‬ﺑﻭﺻﺔ‬
‫ﻭﺃﻧﺎﺑﻳﺏ ﺍﻟﺻﺭﻑ ﺍﻟﺭﺋﻳﺳﻳﺔ ‪ 1-2‬ﺑﻭﺻﺔ‪.‬‬
‫• ﺃﻥ ﺗﻛﻭﻥ ﺑﺩﺍﻳﺔ ﺍﻟﺻﺭﻑ ﻋﻥ ﻁﺭﻳﻖ ﻓﺗﺣﺔ ﺻﺭﻑ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﻛﺛﻔﺔ ﻣﻥ‬
‫ﺍﻟﺗﻛﻳﻳﻑ ﺑﺎﻟﺭﺑﻁ ﺍﻟﻣﺑﺎﺷﺭ ﺃﻭ ﻣﻥ ﻗﺎﻋﺩﺓ ﺗﺟﻣﻳﻊ ﺍﻟﻣﻳﺎﻩ ﻏﻳﺭ ﻗﺎﺑﻠﺔ ﻟﻠﺻﺩﺃ ﺃﻭ‬
‫ﻣﺎ ﻳﻧﺎﺳﺏ ﺗﺻﻣﻳﻡ ﺟﻬﺎﺯ ﺍﻟﺗﻛﻳﻳﻑ ﻟﻐﺭﺽ ﺻﻳﺎﻧﺔ ﻭﺗﻧﻅﻳﻑ ﺍﻟﻣﻛﻳﻑ‪.‬‬
‫ﻳﺟﺏ ﺃﻥ ﻳﻛﻭﻥ ﻟﻠﻧﻅﺎﻡ ﻣﺻﻔﺎﺓ ﺃﻭﺳﺎﺥ ﻓﻲ ﺑﺩﺍﻳﺔ ﺍﻟﺻﺭﻑ ﻟﻣﻧﻊ ﺩﺧﻭﻝ‬ ‫•‬
‫ﺍﻟﺣﺷﺭﺍﺕ‪.‬‬
‫ﻳﺟﺏ ﺃﻥ ﻳﻛﻭﻥ ﻟﻠﻧﻅﺎﻡ ﻓﺗﺣﺎﺕ ﺗﻬﻭﻳﺔ ﻭﻓﺗﺣﺎﺕ ﺗﻧﻅﻳﻑ‪.‬‬ ‫•‬
‫ﻳﺟﺏ ﺃﻥ ﻳﺣﺻﻝ ﻋﻠﻰ ﺍﻟﻣﻭﺍﻓﻘﺔ ﻭﺍﻟﺗﺻﺩﻳﻖ ﻋﻠﻰ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻟﺧﺎﺻﺔ‬ ‫•‬
‫ﺻﺭﻑ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﻛﺛﻔﺔ‪.‬‬
‫ﺍﻟﻣﺣﺎﺑﺱ ﺍﻟﻣﺎﺋﻳﺔ ﺑﺎﻷﺟﻬﺯﺓ ﺍﻟﺻﺣﻳﺔ‬ ‫•‬
‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﻣﺣﺎﺑﺱ ﺑﺎﻷﺟﻬﺯﺓ‬ ‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺗﺎﻟﻳﺔ‬
‫ﺍﻟﺻﺣﻳﺔ‪:‬‬
‫• ﺍﻟﻣﺭﺣﺎﺽ ‪ (WC):‬ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ ﺍﻟﻣﺣﺑﺱ ﻋﻥ ‪ 75‬ﻣﻠﻡ‬
‫ﻭﻋﻣﻖ ﺍﻟﻣﺣﺑﺱ ﻋﻥ ‪ 50‬ﻣﻠﻡ ﻭﻳﺗﻡ ﺗﻭﺻﻳﻠﻪ ﻣﺑﺎﺷﺭﺓ ﺇﻟﻰ ﻏﺭﻓﺔ‬
‫ﺍﻟﺗﻔﺗﻳﺵ‪.‬‬
‫• ﺣﻭﺽ ﻏﺳﻳﻝ ﺍﻷﻳﺩﻱ ‪ (BASIN WASH):‬ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ‬
‫ﺍﻟﻣﺣﺑﺱ ﺍﻟﻣﺎﺋﻲ ﻋﻥ ‪ 23‬ﻣﻠﻡ ﻭﻋﻣﻖ ﺍﻟﻣﺣﺑﺱ ﻋﻥ ‪ 75‬ﻣﻠﻡ‪.‬‬
‫• ﺍﻟﺷﻁﺎﻑ ‪(BEDIET):‬ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ ﺍﻟﻣﺣﺑﺱ ﺍﻟﻣﺎﺋﻲ ﻋﻥ‬
‫‪32‬ﻣﻠﻡ ﻭﻋﻣﻖ ﺍﻟﻣﺣﺑﺱ ﺍﻟﻣﺎﺋﻲ ﻋﻥ‪ 75‬ﻣﻠﻡ‪.‬‬
‫• ﺣﻭﺽ ﻏﺳﻳﻝ ﺍﻟﻣﻁﺑﺦ ‪ (SINK):‬ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ ﺍﻟﻣﺣﺑﺱ ﻋﻥ‬
‫‪40‬ﻣﻠﻡ ﻭﻋﻣﻖ ﺍﻟﻣﺣﺑﺱ ﺍﻟﻣﺎﺋﻲ ﻋﻥ ‪ 75‬ﻣﻠﻡ‪.‬‬
‫• ﺣﻭﺽ ﺍﻟﺣﻣﺎﻡ ‪(BANUE):‬ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ ﺍﻟﻣﺣﺑﺱ ﻋﻥ ‪40‬‬
‫ﻣﻠﻡ ﻭﻋﻣﻖ ﺍﻟﻣﺣﺑﺱ ﺍﻟﻣﺎﺋﻲ ﻋﻥ ‪ 75‬ﻣﻠﻡ‪.‬‬
‫• ﻟﻠﺩﻭﺵ ‪ (SHOWER) :‬ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ ﺍﻟﻣﺣﺑﺱ ﻋﻥ‪ 40‬ﻣﻠﻡ‬
‫ﻭﻋﻣﻖ ﺍﻟﻣﺣﺑﺱ ﺍﻟﻣﺎﺋﻲ ﻋﻥ ‪ 75‬ﻣﻠﻡ‪.‬‬
‫• ﻣﺭﺍﺣﻳﺽ ﺍﻟﻣﻳﺎﻩ) ‪ (URINALS‬ﻳﺟﺏ ﺃﻥ ﻻ ﻳﻘﻝ ﻗﻁﺭ ﺍﻟﻣﺣﺑﺱ ﻋﻥ‬
‫‪40‬ﻣﻠﻡ ﻭﻋﻣﻖ ﺍﻟﻣﺣﺑﺱ ﺍﻟﻣﺎﺋﻲ ﻋﻥ ‪ 75‬ﻣﻠﻡ ﻭﻳﺗﻡ ﺗﻭﺻﻳﻠﻬﺎ‬
‫ﻟﻣﺣﺑﺱ ﺍﻟﻣﺟﺎﺭﻱ‪.‬‬

‫ﻣﻭﺍﺩ ﺗﻣﺩﻳﺩﺍﺕ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ‬ ‫•‬


‫ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺗﺎﻟﻳﺔ ﺑﺗﻣﺩﻳﺩﺍﺕ ﺍﻟﺻﺭﻑ ﺍﻟﺻﺣﻲ‪:‬‬
‫ﺃﻥ ﺗﻛﻭﻥ ﻣﻭﺍﺩ ﺍﻟﺗﻣﺩﻳﺩﺍﺕ ﺍﻷﺭﺿﻳﺔ ﻭﺍﻟﻌﻣﻭﺩﻳﺔ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﺍﻷﺟﻬﺯﺓ‬ ‫•‬
‫ﺍﻟﺻﺣﻳﺔ ﻁﺑﻘﺎ ﻟﻠﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻌﺎﻟﻣﻳﺔ ﻭﺃﻥ ﺗﻧﺎﺳﺏ ﺍﻟﻣﻧﺎﺥ ﻭﺍﻟﻁﺑﻳﻌﺔ‬
‫ﺍﻟﻣﺣﻠﻳﺔ‪.‬‬
‫ﺃﻥ ﺗﻛﻭﻥ ﺃﺳﻁﺢ ﺩﻭﺭﺍﺕ ﺍﻟﻣﻳﺎﻩ ﻭﻣﺭﺣﺎﺽ ﺍﻟﻣﻳﺎﻩ ﻭﺃﺣﻭﺍﺽ‬ ‫•‬
‫ﺍﻟﻐﺳﻳﻝ ﻧﺎﻋﻣﺔ ﻭﺳﻬﻠﺔ ﺍﻟﺗﻧﻅﻳﻑ ﻭﻏﻳﺭ ﺍﻣﺗﺻﺎﺻﻳﺔ ﻛﻣﺎ ﻳﺟﺏ ﺃﻥ‬
‫ﺗﻛﻭﻥ ﻫﺫﻩ ﺍﻟﺗﺭﻛﻳﺑﺎﺕ ﻣﺻﻧﻭﻋﺔ ﻭﻣﺭﻛﺑﺔ ﺑﻣﺎ ﻳﺅﻣﻥ ﺗﺻﺭﻳﻑ ﻣﺎﺑﻬﺎ‬
‫ﺩﻭﻥ ﺗﺧﺯﻳﻥ ﻣﻥ ﺧﻼﻝ ﻣﺣﺑﺱ ﻣﺎﺋﻲ ﻣﺣﻣﻲ ﻣﻥ ﺗﺑﺧﺭ ﺃﻭ ﺟﻔﺎﻑ‬
‫ﻣﺎﺋﺔ ﻭﻳﺟﺏ ﻛﺫﻟﻙ ﺃﻥ ﺗﻛﻭﻥ ﺧﺯﺍﻧﺎﺕ ﻻﻁﺭﺩ ﺍﻟﺧﺎﺻﺔ ﺑﺎﻟﻣﺭﺍﺣﻳﺽ‬
‫ﻭﻣﺭﺍﺣﻳﺽ ﺍﻟﻣﻳﺎﻩ ﻣﻥ ﻧﻭﻉ ﻓﻌﺎﻝ ﻗﺎﺩﺭ ﻋﻠﻰ ﺗﻧﻅﻳﻑ ﺑﻘﺎﻳﺎ ﺍﻟﻔﺿﻼﺕ‬
‫ﻭﺗﺗﺣﻣﻝ ﺇﺟﻬﺎﺩ ﺍﻟﺗﺷﻐﻳﻝ ﻓﻲ ﺍﻷﻣﺎﻛﻥ ﺍﻟﻌﺎﻣﺔ‪.‬‬
‫ﺃﻥ ﺗﻛﻭﻥ ﺃﻧﺎﺑﻳﻳﺏ ﺍﻟﺻﺭﻑ ﻣﺻﻧﻭﻋﺔ ﻣﻥ ﻣﻭﺍﺩ ﻣﻌﺗﻣﺩﺓ ﻭﺗﻧﻔﺫ ﻁﺑﻘﺎ‬ ‫•‬
‫ﻟﻠﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻔﻧﻳﺔ ‪ .‬ﻛﻣﺎ ﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﻭﺻﻼﺗﻬﺎ ﻣﺎﻧﻌﺔ ﻟﺗﺳﺭﺏ‬
‫ﺍﻟﻣﺎء ﻭﺃﻥ ﻻ ﻳﻧﺗﺞ ﻋﻧﻬﺎ ﺃﻱ ﻋﻭﺍﺋﻖ ﺩﺍﺧﻝ ﺍﻷﻧﺎﺑﻳﺏ ﻭﺃﻥ ﺗﻛﻭﻥ‬
‫ﻗﺎﺩﺭﺓ ﻋﻠﻰ ﺗﺣﻣﻝ ﺿﻐﻁ ﻻ ﻳﻘﻝ ﻛﺣﺩ ﺃﺩﻧﻰ ﻋﻠﻰ ﺇﺭﺗﻔﺎﻉ )‪3‬ﻡ( ﻣﻥ‬
‫ﺍﻟﻣﻳﺎﻩ‪.‬‬
‫ﺍﻟﻣﻧﺎﻓﻊ ﺍﻟﺻﺣﻳﺔ‬ ‫•‬
‫ﺗﺯﻭﺩ ﻛﻝ ﻭﺣﺩﺓ ﺳﻛﻧﻳﺔ ﻣﺳﺗﻘﻠﺔ ﺗﺣﺗﻭﻱ ﻏﺭﻓﺔ ﻭﺍﺣﺩﺓ ﺃﻭ ﻏﺭﻓﺗﻳﻥ ﻟﻠﻧﻭﻡ‬ ‫•‬
‫ﺑﺣﻣﺎﻡ ﻭﺍﺣﺩ ﻋﻠﻰ ﺍﻷﻗﻝ ﺑﺷﺭﻁ ﺃﻻ ﻳﻔﺗﺢ ﻣﺑﺎﺷﺭﺓ ﻋﻠﻰ ﺃﻳﺔ ﻏﺭﻓﺔ ﻧﻭﻡ‬
‫ﻭﻳﺳﻣﺢ ﻓﻲ ﺣﺎﻟﺔ ﺗﻌﺩﺩ ﺍﻟﺣﻣﺎﻣﺎﺕ ﻓﻲ ﺃﻳﺔ ﻭﺣﺩﺓ ﺳﻛﻧﻳﺔ ﺃﻥ ﺗﻔﺗﺢ ﺍﻟﺣﻣﺎﻣﺎﺕ‬
‫ﺍﻹﺿﺎﻓﻳﺔ ﻋﻠﻰ ﻏﺭﻑ ﺍﻟﻧﻭﻡ ﻣﺑﺎﺷﺭﺓ‪.‬‬
‫ﻳﺟﺏ ﻓﺻﻝ ﺍﻟﻣﺭﺍﺣﻳﺽ ﺍﻟﻣﺗﺟﺎﻭﺭﺓ ﻓﻲ ﺩﻭﺭﺓ ﻣﻳﺎﻩ ﻭﺍﺣﺩﺓ ﻣﺟﻣﻌﺔ‬ ‫•‬
‫ﺑﻔﻭﺍﺻﻝ ﻻ ﻳﻘﻝ ﺇﺭﺗﻔﺎﻋﻬﺎ ﻋﻥ ‪ 1.8‬ﻣﺗﺭ ﻣﻥ ﻣﻧﺳﻭﺏ ﺗﺷﻁﻳﺑﺎﺕ ﺍﻷﺭﺿﻳﺎﺕ‬
‫‪.‬ﻛﻣﺎ ﻳﺷﺗﺭﻁ ﺗﺭﻛﻳﺏ ﻓﻭﺍﺻﻝ ﺭﺃﺳﻳﺔ ﺑﻳﻥ ﻛﻝ ﻣﺑﻭﻟﺔ ﻭﺃﺧﺭﻯ ﻓﻲ ﻣﺟﻣﻭﻋﺔ‬
‫ﺍﻟﻣﺑﺎﻭﻝ‪.‬‬
‫ﻳﺣﺩﺩ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻟﻌﺩﺩ ﺍﻷﺟﻬﺯﺓ ﺍﻟﺻﺣﻳﺔ ﺍﻟﻣﺭﻛﺑﺔ ﻓﻲ ﻛﻝ ﺑﻧﺎء ﻣﻧﺳﻭﺑﺔ‬ ‫•‬
‫ﺇﻟﻰ ﻋﺩﺩ ﺍﻷﺷﺧﺎﺹ ﻭﺣﺳﺏ ﺍﺳﺗﺧﺩﺍﻣﺎﺕ ﺍﻟﺑﻧﺎء ﻋﻠﻰ ﺍﻟﻧﺣﻭ ﺍﻟﻭﺍﺭﺩ ﻓﻲ‬
‫ﺍﻟﺟﺩﻭﻝ ﺍﻟﺗﺎﻟﻲ‪:‬‬
‫ﺻﻧﺑﻭﺭ‬
‫ﺩﺵ‬ ‫ﺣﻭﺽ ﻏﺳﻳﻝ‬
‫ﻣﻳﺎﻩ‬ ‫ﺃﻳﺩﻱ‬
‫ﻣﺑﻭﻟﺔ‬ ‫ﻣﺭﺣﺎﺽ‬
‫ﺍﻟﺷﺭﺏ‬ ‫ﺍﺳﺗﺧﺩﺍﻡ‬
‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﺍﻟﺑﻧﺎء‬
‫ﺍﻷﺟﻬﺯﺓ‬ ‫ﺍﻷﺟﻬﺯﺓ‬ ‫ﺍﻷﺷﺧﺎﺹ‬ ‫ﺍﻷﺟﻬﺯﺓ‬ ‫ﺍﻷﺷﺧﺎﺹ ﺍﻷﺟﻬﺯﺓ‬
‫ﺍﻟﺭﺟﺎﻝ‬
‫‪30:11‬‬
‫ﻋﺩﺩ ‪ 1‬ﺇﻟﻰ‬ ‫‪10:01‬‬
‫‪1‬‬
‫‪100‬ﺷﺧﺹ‬ ‫‪80:31‬‬
‫(ﺣﻭﺽ‬ ‫‪25:11‬‬ ‫ﺍﻟﻣﺑﺎﻧﻲ‬
‫‪2‬‬
‫ﺻﻧﺑﻭﺭ‬ ‫ﻏﺳﻳﻝ ﻟﻛﻝ‬ ‫‪160:81‬‬ ‫ﺍﻟﺻﻧﺎﻋﻳﺔ‬
‫ﺩﺵ‬ ‫‪50:26‬‬
‫ﻣﻳﺎﻩ‬ ‫‪10‬ﺃﺷﺧﺎﺹ)‬ ‫‪3‬‬ ‫ﻣﺧﺯﻥ‬
‫ﻭﺍﺣﺩ‬ ‫‪240:161‬‬
‫ﻭﺍﺣﺩ‬ ‫ﻣﺳﺑﻙ ‪75: 51‬‬
‫ﻟﻛﻝ ‪15‬‬ ‫ﺃﻛﺛﺭ ﻣﻥ‬ ‫‪4‬‬
‫ﻟﻛﻝ ‪15‬‬ ‫‪-‬‬ ‫ﻭﺭﺷﺔ‬
‫ﺷﺧﺹ‬ ‫ﻭﻣﺎ ﻓﻲ ‪100:76‬‬
‫ﺷﺧﺹ‬ ‫‪100‬ﺷﺧﺹ‬ ‫‪5‬‬
‫(ﺣﻭﺽ‬ ‫ﺣﻛﻣﺔ‬
‫ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ ﺇﺿﺎﻓﻲ‬
‫ﻏﺳﻳﻝ ﻟﻛﻝ ‪15‬‬
‫ﻟﻛﻝ‪ 30‬ﺷﺧﺹ‬
‫ﺷﺧﺹ)‬

‫ﺻﻧﺑﻭﺭ‬ ‫ﺣﻭﺽ‬
‫ﻏﺳﻳﻝ‬ ‫ﺣﻭﺽ‬
‫ﻣﻳﺎﻩ‬ ‫ﻏﺳﻳﻝ ﺃﻳﺩﻱ‬
‫ﻣﺑﻭﻟﺔ‬ ‫ﻣﺭﺣﺎﺽ‬
‫ﺍﻟﺷﺭﺏ‬ ‫ﺃﻳﺩﻱ‬ ‫ﺍﺳﺗﺧﺩﺍﻡ‬
‫ﺍﻟﺑﻧﺎء‬
‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬ ‫ﻋﺩﺩ‬
‫ﺍﻷﺟﻬﺯﺓ‬ ‫ﺍﻷﺟﻬﺯﺓ‬ ‫ﺍﻷﺷﺧﺎﺹ‬ ‫ﺍﻷﺟﻬﺯﺓ‬ ‫ﺍﻷﺟﻬﺯﺓ‬ ‫ﺍﻷﺷﺧﺎﺹ‬
‫ﺍﻟﺭﺟﺎﻝ‬
‫‪-‬‬ ‫‪1‬‬ ‫ﺇﻣﻛﺎﻧﻳﺔ ﺗﺟﻬﻳﺯ‬
‫‪15:1‬‬ ‫‪15:01‬‬ ‫ﺍﻟﻣﻧﺷﺂﺕ‬
‫‪2‬‬ ‫ﺍﻟﻣﺑﺎﻭﻝ‬ ‫‪1‬‬
‫‪35:16‬‬ ‫ﺍﻟﻌﺎﻣﺔ‬
‫‪35:16‬‬
‫‪2‬‬ ‫ﻭﺍﻟﻣﻛﺎﺗﺏ‬
‫‪-‬‬ ‫‪3‬‬ ‫‪60:36‬‬ ‫ﻓﻲ ﺩﻭﺭﺍﺕ ﻣﻳﺎﻩ‬ ‫‪3‬‬ ‫‪55:36‬‬
‫‪4‬‬ ‫‪90:61‬‬ ‫ﻭﻣﺎ‬
‫‪-‬‬ ‫ﺍﻟﺭﺟﺎﻝ ﺍﻟﻣﺟﻣﻌﺔ‬ ‫‪4‬‬ ‫‪56: 80‬‬ ‫ﻓﻲ‬
‫‪5‬‬ ‫‪125:91‬‬
‫ﺷﺭﻁ ﺃﻻ ﺗﺯﻳﺩ‬ ‫‪5‬‬ ‫‪11:81‬‬ ‫ﺣﻛﻣﻪ‬
‫ﺣﻭﺽ ﻏﺳﻳﻝ ﺍﻻﻳﺩﻱ‬
‫ﻭﺍﺣﺩ ﻟﻛﻝ ‪ 45‬ﺷﺧﺻﺎ‬ ‫ﻋﻥ ‪ 1/3‬ﻋﺩﺩ‬ ‫‪6‬‬ ‫‪150:111‬‬
‫ﺍﺿﺎﻓﻳﻪ‬
‫ﺍﻟﻣﺭﺍﺣﻳﺽ‬ ‫ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ ﺇﺿﺎﻓﻲ‬
‫ﻟﻛﻝ‪ 30‬ﺷﺧﺹ‬
‫ﺍﻟﻣﻁﻠﻭﺑﺔ‬

‫ﺻﻧﺑﻭﺭ‬ ‫ﻣﺭﺣﺎﺽ‬
‫ﺣﻭﺽ‬ ‫ﺣﻭﺽ‬ ‫ﺑﻧﺎﺕ‬ ‫ﺃﻭﻻﺩ‬
‫ﻣﻳﺎﻩ‬ ‫ﻣﺑﻭﻟﺔ‬ ‫ﺍﻟﻣﺩﺍﺭﺱ‬
‫ﻏﺳﻳﻝ ﺃﻳﺩﻱ ﻏﺳﻳﻝ ﺃﻳﺩﻱ‬
‫ﺍﻟﺷﺭﺏ‬
‫ﺻﻧﺑﻭﺭ ﻟﻛﻝ‬ ‫ﻓﻲ ﺻﺎﻟﺔ‬ ‫ﺣﻭﺽ ﻟﻛﻝ‬
‫ﻣﺑﻭﻟﺔ ﻟﻛﻝ ‪30‬‬ ‫ﻣﺭﺣﺎﺽ‬ ‫ﻣﺭﺣﺎﺽ‬
‫‪100‬ﺗﻠﻣﻳﺫ‬ ‫ﺍﻷﻟﻌﺎﺏ‬ ‫‪50‬ﺗﻠﻣﻳﺫ‬ ‫ﺍﻹﻋﺩﺍﺩﻳﺔ‬
‫ﻭﻟﺩ‬ ‫ﻟﻛﻝ‪35‬‬ ‫ﻟﻛﻝ‪40‬‬
‫ﻋﻠﻰ ﺍﻷﻗﻝ‬ ‫ﺍﻟﺭﻳﺎﺿﻳﺔ ﺃﻭ‬ ‫ﻭﺗﻠﻣﻳﺫﻩ‬
‫ﺃﻭ ﺻﻧﺑﻭﺭ‬ ‫ﺣﻣﺎﻡ ﺳﺑﺎﺣﺔ‬ ‫ﺣﻭﺽ ﻟﻛﻝ‬
‫ﻣﺑﻭﻟﺔ ﻟﻛﻝ‬ ‫ﻣﺭﺣﺎﺽ‬ ‫ﻣﺭﺣﺎﺽ‬
‫ﻟﻛﻝ ﻁﺎﺑﻖ‬ ‫(ﺩﺵ ﻟﻛﻝ ‪5‬‬ ‫‪50‬ﺗﻠﻣﻳﺫ‬ ‫ﺍﻟﺛﺎﻧﻭﻳﺔ‬
‫‪30‬ﻭﻟﺩ‬ ‫ﻟﻛﻝ‪45‬‬ ‫ﻟﻛﻝ‪75‬‬
‫ﺩﺭﺍﺳﻲ‬ ‫ﺗﻼﻣﻳﺫ)‬ ‫ﻭﺗﻠﻣﻳﺫﻩ‬
‫ﻣﻥ ‪150:1‬‬ ‫ﺣﻭﺽ‬ ‫ﻣﻥ‪150:1‬‬
‫ﺷﺧﺻﺎ( ﺩﺵ‬ ‫ﻏﺳﻳﻝ ﺍﻳﺩﻱ‬ ‫ﺭﺟﻼ( ﻣﺑﻭﻟﺔ‬ ‫ﺭﺟﺎﻝ ‪ :‬ﻣﺭﺣﺎﺽ ﻟﻛﻝ‬ ‫ﺍﻟﺳﻛﻥ‬
‫ﻟﻛﻝ ‪8‬‬ ‫ﻭﺍﺣﺩ ﻟﻛﻝ‬ ‫ﻭﺍﺣﺩ ﻟﻛﻝ‬ ‫‪10‬ﺭﺟﺎﻝ‬ ‫ﺍﻟﺩﺍﺧﻠﻲ‬
‫ﺃﺷﺧﺎﺹ)‬ ‫‪12‬ﺷﺧﺹ‬ ‫‪25‬ﺭﺟﻝ )‬ ‫ﻣﺩﺍﺭﺱ‬
‫ﺻﻧﺑﻭﺭ‬ ‫ﺩﺍﺧﻠﻳﺔ‬
‫ﻟﻛﻝ ‪75‬‬ ‫ﺍﻛﺛﺭ ﻣﻥ‬ ‫ﻧﺳﺎء ‪:‬ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ‬ ‫ﺑﻳﻭﺕ‬
‫ﺷﺧﺹ‬ ‫‪150‬‬ ‫ﺃﻛﺛﺭ ﻣﻥ‪150‬‬ ‫ﻟﻛﻝ ‪ 8‬ﻧﺳﺎء‬ ‫ﺷﺑﺎﺏ‬
‫ﺷﺧﺻﺎ(ﺩﺵ‬ ‫ﺭﺟﻼ( ﻣﺑﻭﻟﺔ‬ ‫ﻋﻣﺎﻝ‬
‫ﻟﻛﻝ ‪20‬‬ ‫ﻭﺍﺣﺩ ﻟﻛﻝ‬ ‫ﻭﻣﺎﻓﻲ‬
‫ﺃﺷﺧﺎﺹ)‬ ‫‪50‬ﺭﺟﻝ )‬ ‫ﺣﻛﻣﻪ‬

‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﺳﻛﻥ ﺍﻟﺩﺍﺧﻠﻲ ﻓﻲ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺳﻛﻧﻳﺔ ﺍﻟﻣﻧﻔﺻﻠﺔ ﻟﻸﺷﺧﺎﺹ‬ ‫•‬


‫ﺍﻟﻌﺎﺩﻳﻳﻥ ﻳﺣﺩﺩ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﺍﻟﺗﺎﻟﻲ‪:‬‬
‫• ‪-‬ﻟﻛﻝ ﻭﺣﺩﺓ ﺻﻐﻳﺭﺓ ‪ :‬ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ ﻭﺣﻭﺽ ﻏﺳﻳﻝ ﺃﻳﺩﻱ ﻭﺍﺣﺩ ﻭ‬
‫ﺩﺵ ﻭﺍﺣﺩ ﻭﺣﻭﺽ ﻣﻁﺑﺦ ﻭﺍﺣﺩ‪.‬‬
‫• ‪-‬ﻟﻛﻝ ﻭﺣﺩﻩ ﻣﺟﻣﻌﺔ ﻟﻌﺩﺩ‪ 6‬ﻏﺭﻑ ﻧﻭﻡ ﻣﻧﻔﺻﻠﺔ ‪ :‬ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ‬
‫ﻭﺣﻭﺽ ﻏﺳﻳﻝ ﺃﻳﺩﻱ ﻭﺍﺣﺩ ﻭﺩﺵ ﻭﺍﺣﺩ‪.‬‬
‫• ‪-‬ﻛﻝ ﻋﻧﺑﺭ ﻧﻭﻡ ‪ 15‬ﺷﺧﺹ ‪ :‬ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ ﻭﺣﻭﺽ ﻏﺳﻳﻝ ﺃﻳﺩﻱ‬
‫ﻭﺍﺣﺩ ﻭﺩﺵ ﻭﺍﺣﺩ ‪.‬‬
‫ﻳﺣﺩﺩ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻟﻠﻣﺳﺗﺷﻔﻳﺎﺕ ﻭﻓﻘﺎ ﻟﻠﺗﺎﻟﻲ ‪:‬‬
‫• ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ ﻭﺣﻭﺽ ﻏﺳﻳﻝ ﺃﻳﺩﻱ ﻭﺍﺣﺩ ﻟﻛﻝ ‪ 10‬ﻣﺭﺿﻰ ‪.‬‬
‫• ﺩﺵ ﻭﺍﺣﺩ ﻟﻛﻝ‪ 20‬ﻣﺭﻳﺽ ‪.‬‬
‫• ﺻﻧﺑﻭﺭ ﻣﻳﺎﻩ ﺷﺭﺏ ﻟﻛﻝ‪ 100‬ﻣﺭﻳﺽ ‪.‬‬
‫• ﺑﺎﻟﻧﺳﺑﺔ ﻟﻣﺳﺗﺷﻔﻳﺎﺕ ﺍﻷﻣﺭﺍﺽ ﺍﻟﻧﻔﺳﻳﺔ ‪ :‬ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ ﻭﺣﻭﺽ‬
‫ﻏﺳﻳﻝ ﺃﻳﺩﻱ ﻭﺍﺣﺩ ﻟﻛﻝ‪ 8‬ﻣﺭﺿﻰ ﻛﺫﻟﻙ ﺻﻧﺑﻭﺭ ﻣﻳﺎﻩ ﺷﺭﺏ ﻟﻛﻝ‬
‫‪50‬ﻣﺭﻳﺽ ‪.‬‬
‫ﻳﺣﺩﺩ ﺍﻟﺣﺩ ﺍﻷﺩﻧﻰ ﻟﺣﻣﺎﻣﺎﺕ ﺍﻟﺳﺑﺎﺣﺔ ﺍﻟﻌﺎﻣﺔ ﻭﺍﻷﻧﺩﻳﺔ ﺍﻟﺭﻳﺎﺿﻳﺔ ﻛﺎﻟﺗﺎﻟﻲ ‪:‬‬
‫• ﻣﺭﺣﺎﺽ ﻭﺍﺣﺩ ﻟﻛﻝ ‪ 40‬ﺳﻳﺩﺓ ﺍﻭ ‪ 60‬ﺭﺟﻼ‪.‬‬
‫• ﻣﺑﻭﻟﺔ ﻭﺍﺣﺩﺓ ﻟﻛﻝ ‪ 60‬ﺭﺟﻼ‪.‬‬
‫• ﺣﻭﺽ ﻏﺳﻳﻝ ﺃﻳﺩﻱ ﻟﻛﻝ ‪ 40‬ﺳﻳﺩﺓ ﺍﻭ ‪60‬ﺭﺟﻼ‪.‬‬
‫• ﺩﺵ ﻭﺍﺣﺩ ﻟﻛﻝ ‪ 40‬ﺳﻳﺩﺓ ﺃﻭ ﺭﺟﻼ‪.‬‬
‫ﻓﻲ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺳﻛﻳﻧﺔ ﺍﻟﺟﻣﺎﻋﻳﺔ ﻭﺍﻟﺳﻛﻥ ﺍﻟﺩﺍﺧﻠﻲ ﻳﺟﺏ ﺗﻭﻓﻳﺭ ﺍﻟﺗﺎﻟﻲ ‪:‬‬
‫• ﺗﺭﻛﻳﺏ ﺣﻭﺽ ﻏﺳﻳﻝ ﻣﻼﺑﺱ ﻟﻛﻝ ‪ 50‬ﺷﺧﺻﺎ ﻭﺣﻭﺽ ﺗﻧﻅﻳﻑ ﺃﻭﺍﻧﻲ‬
‫ﻟﻛﻝ ‪ 100‬ﺷﺧﺹ ﻭﺣﻭﺽ ﻏﺳﻳﻝ ﺃﻳﺩﻱ ﻣﻧﻔﺻﻝ ﻟﻛﻝ ‪ 50‬ﺷﺧﺹ ‪.‬‬
‫ﻭﻓﻲ ﻣﺳﺎﻛﻥ ﺍﻟﻌﻣﺎﻝ ﺍﻟﻣﺅﻗﺕ ﺑﻣﻭﺍﻗﻊ ﺍﻟﻌﻣﻝ ﻓﻲ ﺗﺷﻳﻳﺩ ﺍﻟﺑﻧﺎء ﻭﻣﺟﺎﻻﺕ‬
‫ﻭﻣﺎ ﻳﻣﺎﺛﻠﻬﺎ ﺗﺭﻛﻳﺏ ﺩﻭﺭﺓ ﻣﻳﺎﻩ ﻟﻛﻝ ‪ 30‬ﺷﺧﺹ ‪.‬‬

‫ﺍﻻﺷﺗﺭﺍﻁﺎﺕ ﺍﻹﻧﺷﺎﺋﻳﺔ ﻟﻠﻣﺑﺎﻧﻲ‬ ‫•‬


‫ﻳﺟﺏ ﺃﻥ ﻳﺗﻡ ﺇﻋﺩﺍﺩ ﺍﻟﺗﺻﻣﻳﻡ ﺍﻹﻧﺷﺎﺋﻲ ﻟﻠﻣﺑﺎﻧﻲ ﻭﺍﻟﻣﻧﺷﺂﺕ ﺑﻭﺍﺳﻁﺔ‬ ‫•‬
‫ﻣﻬﻧﺩﺱ ﺇﻧﺷﺎﺋﻲ ﻣﺅﻫﻝ ﻭﻣﺭﺧﺹ ﺑﻣﺯﺍﻭﻟﺔ ﺍﻟﻣﻬﻧﺔ ﻭﻣﻌﺗﻣﺩ ﻣﻥ ﻗﺑﻝ‬
‫ﺍﻟﺑﻠﺩﻳﺔ ‪.‬‬
‫ﻳﺟﺏ ﺃﻥ ﻳﺗﻭﻓﺭ ﻓﻲ ﺍﻟﻣﺑﺎﻧﻲ ﻭﺍﻟﻣﻧﺷﺊ ﺑﻛﺎﻣﻝ ﺃﺟﺯﺍﺋﻬﺎ ﻭﺍﻟﻣﻭﺍﺩ‬ ‫•‬
‫ﺍﻟﺩﺍﺧﻠﺔ ﻓﻲ ﺇﻧﺷﺎﺋﻬﺎ ﺍﻟﻘﺩﺭ ﺍﻟﻛﺎﻓﻲ ﻣﻥ ﺍﻷﻣﺎﻥ ﻭﺍﻟﺣﻣﺎﻳﺔ ﻣﻥ ﺍﻟﻌﻭﺍﻣﻝ‬
‫ﺍﻟﺗﺎﻟﻳﺔ ‪:‬‬
‫ﺃﻛﺛﺭ ﺍﻟﻘﻭﻯ ﻭﺍﻷﺣﻣﺎﻝ ﺃﻭ ﻣﺟﻣﻭﻋﺗﻬﺎ ﺧﻁﻭﺭﺓ ﻓﻲ ﺍﻟﺗﺄﺛﻳﺭ ﻋﻠﻰ‬ ‫•‬
‫ﺍﻟﻣﻧﺷﺄﺓ ‪ .‬ﺑﻣﺎ ﻓﻲ ﺫﻟﻙ ﻣﺟﻣﻭﻋﺎﺕ ﺍﻟﻘﻭﻯ ﻭﺍﻷﺣﻣﺎﻝ ﺍﻟﺗﻲ ﻗﺩ ﺗﺅﺩﻱ‬
‫ﺇﻟﻰ ﺍﻹﻧﻬﻳﺎﺭ ﺍﻟﻣﺗﺗﺎﻟﻲ ‪.‬‬
‫ﺃﻳﺔ ﻣﺅﺛﺭﺍﺕ ﺃﺧﺭﻯ ﺑﻣﺎ ﻓﻳﻬﺎ ﺗﺂﻛﻝ ﻭﺻﺩﺃ ﺍﻟﺣﺩﻳﺩ ﺍﻟﺫﻱ ﻗﺩ ﻳﺗﻌﺭﺽ ﻟﻪ‬ ‫•‬
‫ﺍﻟﻣﺑﻧﻰ ‪.‬‬

‫ﺍﻟﻣﻌﻠﻭﻣﺎﺕ ﺍﻟﻣﻁﻠﻭﺏ ﺗﻭﻓﺭﻫﺎ ﻓﻲ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻹﻧﺷﺎﺋﻳﺔ‬ ‫•‬

‫ﻟﻠﺑﻧﺎﻳﺎﺕ‬
‫ﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻹﻧﺷﺎﺋﻳﺔ ﻟﻠﻣﺳﺎﻗﻁ ﺍﻷﻓﻘﻳﺔ ﻭﺍﻟﺭﺃﺳﻳﺔ ﺑﻣﻘﻳﺎﺱ‬ ‫•‬
‫ﺭﺳﻡ ‪ 100:1‬ﻭﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﺍﻟﺗﻔﺎﺻﻳﻝ ﺍﻹﻧﺷﺎﺋﻳﺔ ﺑﻣﻘﻳﺎﺱ ﺭﺳﻡ ‪. 25:1‬‬
‫ﻭﺟﻭﺩ ﻣﺧﻁﻁﺎﺕ ﺑﺎﻟﻣﻼﺣﻅﺎﺕ ﺍﻟﻌﺎﻣﺔ ﺗﺗﺿﻣﻥ ﺍﻟﺗﻔﺎﺻﻳﻝ ﺍﻟﻔﻧﻳﺔ ﻟﻠﺧﺭﺳﺎﻧﺔ‬ ‫•‬
‫ﻣﻥ ﺣﻳﺙ ﺍﻹﺟﻬﺎﺩ ﻭﻧﻭﻉ ﺍﻷﺳﻣﻧﺕ ﺍﻟﻣﺳﺗﺧﺩﻡ ﻭﺍﻟﻐﻁﺎء ﺍﻟﺧﺭﺳﺎﻧﻲ ﻟﻠﺣﺩﻳﺩ‬
‫ﻟﻣﺧﺗﻠﻑ ﺍﻟﻌﻧﺎﺻﺭ ﺍﻹﻧﺷﺎﺋﻳﺔ ﻭﺍﻟﺗﻔﺎﺻﻳﻝ ﺍﻹﻧﺷﺎﺋﻳﺔ ﺍﻟﻛﺎﻣﻠﺔ ﻟﺗﺳﻠﻳﺢ‬
‫ﺍﻟﻌﻧﺎﺻﺭ ﺍﻹﻧﺷﺎﺋﻳﺔ ﺍﻟﻣﺧﺗﻠﻔﺔ ﻣﻥ ﻗﻭﺍﻋﺩ ﻭﺃﻋﻣﺩﺓ ﻭﻛﻣﺭﺍﺕ ﺑﻼﻁﺎﺕ‬
‫ﻭﺣﻭﺍﺋﻁ ﻭﺳﻼﻟﻡ ‪.‬‬
‫ﻳﺗﻡ ﺗﺣﺩﻳﺩ ﺣﺩﻭﺩ ﺍﻷﺭﺽ ﻋﻠﻰ ﻟﻭﺣﺔ ﺍﻟﻘﻭﺍﻋﺩ ﻟﻣﻌﺭﻓﺔ ﺑﺭﻭﺯ ﺍﻟﻘﻭﺍﻋﺩ‬ ‫•‬
‫) ﺍﻟﺧﻭﺍﺯﻳﻖ ‪-‬ﺍﻟﺣﺻﻳﺭﻩ (ﺧﺎﺭﺝ ﺣﺩﻭﺩ ﺍﻷﺭﺽ‪.‬‬
‫ﻣﺳﻘﻁ ﺃﻓﻘﻲ ﻟﻣﺣﺎﻭﺭ ﺍﻷﻋﻣﺩﺓ ﻳﺗﺿﻣﻥ ﻣﻘﺎﺳﺎﺕ ﺍﻷﻋﻣﺩﺓ ﺑﺎﻟﻁﻭﺍﺑﻖ‬ ‫•‬
‫ﺍﻟﻣﺧﺗﻠﻔﺔ ﻭﺃﺣﻣﺎﻝ ﺍﻷﺳﺎﺳﺎﺕ ﺗﺗﺿﻣﻥ ﻋﺯﻭﻡ ﺍﻟﺭﻳﺎﺡ ﻭﻋﺯﻭﻡ ﺍﻟﺯﻻﺯﻝ ﺃﻳﻧﻣﺎ‬
‫ﻭﺟﺩﺕ‪.‬‬
‫ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻟﺗﻔﺻﻳﻠﻳﺔ ﻟﻸﺳﺎﺳﺎﺕ ﺗﺗﺿﻣﻥ ﺗﻔﺎﺻﻳﻝ ﺍﻷﺳﺎﺳﺎﺕ ﻣﻥ ﺟﺳﻭﺭ‬ ‫•‬
‫ﺃﺭﺿﻳﺔ ﻭﺍﻟﺟﺳﻭﺭ ﺍﻟﺭﺍﺑﻁﺔ ‪ ،‬ﻭﻛﺫﻟﻙ ﻣﺧﻁﻁﺎﺕ ﺍﻟﻣﺳﺎﻗﻁ ﺍﻷﻓﻘﻳﺔ ﻟﻠﻁﻭﺍﺑﻖ‬
‫ﺍﻟﻣﺧﺗﻠﻔﻪ ﻭﺍﻟﻣﺗﻛﺭﺭﺓ ﻣﻊ ﻣﺧﻁﻁ ﺳﻁﺢ ﻭﺟﺩﺍﻭﻝ ﺣﺩﻳﺩ ﺍﻟﺗﺳﻠﻳﺢ ﻭﺗﻔﺻﻳﻠﻪ‬
‫ﻟﺳﻭﺭ ﺍﻟﺳﻁﺢ ﻣﻊ ﺗﺣﺩﻳﺩ ﺧﺯﺍﻥ ﺍﻟﻣﺎء ﺍﻷﺭﺿﻲ ﻋﻠﻰ ﻟﻭﺣﺔ ﻗﻭﺍﻋﺩ ﻣﻊ‬
‫ﺗﻭﺿﻳﺢ ﺟﻬﺩ ﺍﻟﺗﺭﺑﺔ ﻭﻋﻣﻖ ﺍﻷﺳﺎﺱ ﻭﺇﺣﻼﻝ ﺍﻟﺗﺭﺑﺔ ﺇﻥ ﻭﺟﺩ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺍﻷﺳﺎﺳﺎﺕ ﺍﻟﺧﺎﺯﻭﻗﻳﺔ ﻳﺟﺏ ﺗﻭﺿﻳﺢ ﻁﻭﻝ ﻭﻗﻁﺭ ﺍﻟﺧﺎﺯﻭﻕ‬ ‫•‬
‫ﻭﻁﺭﻕ ﺗﺳﻠﻳﺣﻪ ﻣﻊ ﺗﻭﻓﻳﺭ ﺣﻣﺎﻳﺔ ﻣﻧﺎﺳﺑﺔ ﻟﻪ‪.‬‬
‫ﻳﺗﻡ ﺭﺑﻁ ﺧﻭﺍﺯﻳﻖ ﺍﻟﻣﻧﺗﺻﻑ ﻋﻥ ﻁﺭﻳﻖ ﺍﻟﺟﺳﻭﺭ ﺍﻟﺭﺍﺑﻁﺔ‪.‬‬ ‫•‬
‫ﻣﺧﻁﻁ ﺗﻔﺻﻳﻠﻲ ﻟﺗﺳﻠﻳﺢ ﺍﻟﺳﻠﻡ‪.‬‬ ‫•‬
‫ﻣﺧﻁﻁ ﺗﻔﺻﻳﻠﻲ ﻟﻠﻣﻘﺎﻁﻊ ﻳﺗﺿﻣﻥ ﻣﺳﻘﻁ ﺃﻓﻘﻲ ﻭ ﺭﺃﺳﻲ ﻟﺣﻭﺍﺋﻁ ﺍﻟﻣﺻﻌﺩ‬ ‫•‬
‫ﻭ ﺍﻟﺣﻭﺍﺋﻁ ﺍﻟﺧﺭﺳﺎﻧﻳﺔ ﺍﻷﺧﺭﻯ ﻣﻭﺿﺣﺎ ﺣﺩﻳﺩ ﺗﺳﻳﻠﺢ ﺍﻟﺣﻭﺍﺋﻁ ﻭ ﺣﻭﻝ‬
‫ﺍﻟﻔﺗﺣﺎﺕ ﻭ ﺍﻟﺟﻭﺍﻧﺏ ﻭﺗﻔﺎﺻﻳﻝ ﺍﻷﻋﺗﺎﺏ‪.‬‬
‫ﺗﻭﺿﻳﺢ ﻋﺩﺩ ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻣﺻﻣﻡ ﻋﻠﻳﻬﺎ ﺍﻟﻘﻭﺍﻋﺩ ﻭﻳﺟﺏ ﺃﻥ ﻳﻛﻭﻥ ﻋﺩﺩ‬ ‫•‬
‫ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻣﺻﻣﻣﺔ ﻫﻲ ﻧﻔﺳﻬﺎ ﻣﻌﺗﻣﺩﻩ ﻟﻠﻣﺑﺎﻧﻲ ﻓﻲ ﺍﻟﻣﻭﺍﻓﻘﻪ ﺍﻹﺑﺗﺩﺍﺋﻳﺔ‪.‬‬

‫ﺍﻟﻣﻌﻠﻭﻣﺎﺕ ﺍﻟﻣﻁﻠﻭﺏ ﺗﻭﺍﻓﺭﻫﺎ ﻓﻲ ﺣﺳﺎﺑﺎﺕ ﺍﻟﺗﺻﻣﻳﻡ‬ ‫•‬

‫ﻟﻠﻣﺑﺎﻧﻲ ﺍﻟﺧﺭﺳﺎﻧﻳﺔ‬ ‫ﺝ‬

‫• ﺗﻘﺭﻳﺭ ﺍﻟﺗﺭﺑﺔ ﺍﻷﺻﻠﻲ‪.‬‬


‫• ﻓﻬﺭﺱ ﺑﺄﺭﻗﺎﻡ ﺻﻔﺣﺎﺕ ﻭﻓﺭﻭﺽ ﺍﻟﺗﺻﻣﻳﻡ ﺍﻷﺳﺎﺳﻳﺔ ﻟﻸﺣﻣﺎﻝ ﻭﺟﻬﺩ‬
‫ﺍﻟﺧﺭﺳﺎﻧﻪ ﻭﺍﻟﺣﺩﻳﺩ ﻭﺇﺭﺗﻔﺎﻉ ﺍﻟﻣﺑﻧﻰ ﻭﻋﺩﺩ ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻣﺻﻣﻡ ﻋﻠﻳﻬﺎ‬
‫ﺍﻟﻘﻭﺍﻋﺩ‪ ...‬ﺇﻟﺦ‬
‫• ﺗﻔﺎﺻﻳﻝ ﺃﺣﻣﺎﻝ ﺍﻷﻋﻣﺩﻩ ﻭﺣﺳﺎﺑﺎﺗﻬﺎ ‪ ,‬ﺑﻁﺭﻳﻘﻪ ﺭﺩ ﻓﻌﻝ ﻭﻳﺟﺏ ﺃﻥ ﺗﺣﺗﻭﻱ‬
‫ﺃﺣﻣﺎﻝ ﺍﻷﻋﻣﺩﻩ ﻋﻠﻰ ﻛﻝ ﺍﻷﺣﻣﺎﻝ ‪ ,‬ﻣﺗﺿﻣﻧﺔ ﺍﻟﻭﺯﻥ ﺍﻟﺫﺍﺗﻲ ﻟﻠﺟﺳﻭﺭ‬
‫ﻭﺍﻟﺣﻭﺍﺋﻁ ﻭﺍﻷﻋﻣﺩﺓ ﻭﺃﺳﻭﺍﺭ ﺍﻟﺳﻁﺢ ﻭﺑﻳﺕ ﺍﻟﺳﻠﻡ ﻭﺃﺣﻣﺎﻝ ﺧﺯﺍﻧﺎﺕ‬
‫ﺍﻟﻣﻳﺎﻩ‪ .‬ﻭﻋﻧﺩ ﺍﻟﺗﺩﻗﻳﻖ ﻋﻠﻰ ﺿﻐﻁ ﺍﻟﺗﺭﺑﺔ ﻳﺟﺏ ﺍﻷﺧﺫ ﻑ ﺍﻻﻋﺗﺑﺎﺭ ﻭﺯﻥ‬
‫ﺍﻟﺗﺭﺑﻪ ﻭﻓﻖ ﻣﺳﺗﻭﻯ ﺍﻷﺭﺽ ﺍﻟﻁﺑﻳﻌﻳﺔ ‪ ,‬ﻭﻳﺟﺏ ﺫﻛﺭ ﺃﺣﻣﺎﻝ ﺍﻟﻘﻭﺍﻋﺩ‬
‫ﻋﻠﻰ ﻣﺧﻁﻁ ﺍﻷﻋﻣﺩﺓ ﺍﻟﺭﺋﻳﺳﻳﺔ‪.‬‬
‫• ﻓﻲ ﺣﺎﻟﺔ ﺭﺑﻁ ﺍﻟﻘﻭﺍﻋﺩ ﺑﺟﺳﻭﺭ ﺍﻟﺭﺍﺑﻁﻪ ﻳﺟﺏ ﺃﺧﺫ ﺍﻷﺣﻣﺎﻝ ﺍﻹﺿﺎﻓﻳﺔ‬
‫ﺍﻟﻧﺎﺗﺟﺔ ﻋﻥ ﺍﻟﻼﻣﺭﻛﺯﻳﺔ ﻓﻲ ﺍﻻﻋﺗﺑﺎﺭ‪.‬‬
‫• ﺣﺳﺎﺑﺎﺕ ﺍﻟﺗﺻﻣﻳﻡ ﻟﻸﻋﻣﺩﺓ ﻣﻊ ﺍﻷﺧﺫ ﻓﻲ ﺍﻻﻋﺗﺑﺎﺭ ﺣﺎﻟﺔ ﺍﻷﻋﻣﺩﺓ ﺍﻟﻁﻭﻳﻠﺔ‬
‫ﺑﺎﻹﺿﺎﻓﺔ ﺍﻟﻌﺯﻭﻡ ﺍﻟﻧﺎﺗﺟﺔ ﻋﻥ ﺍﻟﻼﻣﺭﻛﺯﻳﺔ‪.‬‬
‫• ﺃﺣﻣﺎﻝ ﻭﺃﺷﻛﺎﻝ ﺍﻟﻌﺯﻭﻡ ﻭﺍﻟﻘﺹ ﻭﺣﺳﺎﺑﺎﺕ ﺍﻟﺣﺩﻳﺩ ﻟﻛﻝ ﺍﻟﺟﺳﻭﺭ ﺣﻳﺙ‬
‫ﻳﺟﺏ ﺃﻥ ﻳﻛﻭﻥ ﻟﻬﺎ ﻣﺣﺎﻭﺭ ﻟﻠﺭﺟﻭﻉ ﺇﻟﻳﻬﺎ‪.‬‬
‫• ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺃﻋﻣﺩﺓ ﻣﺩﻓﻭﻧﺔ ﻋﻠﻰ ﺍﻟﺟﺳﻭﺭ ﻳﺟﺏ ﺍﻟﺗﺩﻗﻳﻖ ﻋﻠﻰ ﺍﻻﻧﺑﻌﺎﺝ‬
‫ﻛﻣﺎ ﻳﺗﻡ ﺍﻟﺗﺩﻗﻳﻖ ﻋﻠﻰ ﺍﻟﻛﻣﺭﻩ ﻣﻥ ﻧﺎﺣﻳﻪ ﺍﻹﺟﻬﺎﺩ‪.‬‬
‫• ﺑﺎﻟﻧﺳﺑﻪ ﻟﻠﺑﻼﻁﺎﺕ ﻭﺍﻟﺟﺳﻭﺭ ﺍﻟﺣﺎﻣﻠﺔ ﻟﺧﺯﺍﻥ ﺍﻟﻣﻳﺎﻩ ﻳﺟﺏ ﺗﻘﺩﻳﻡ ﺣﺳﺎﺑﺎﺕ‬
‫ﻣﻧﻔﺻﻠﺔ ﻟﻬﺎ‪.‬‬
‫• ﺑﺎﻟﻧﺳﺑﻪ ﻟﻠﺟﺳﻭﺭ ﺍﻟﻣﺩﻓﻭﻧﺔ ﻭﺍﻟﺑﻼﻁﺎﺕ ﺍﻟﺗﻲ ﻟﻬﺎ ﻁﻭﻟﻬﺎ ﺃﻛﺛﺭ ﻣﻥ ‪ 6‬ﻣﺗﺭ‬
‫ﻳﺟﺏ ﺣﺳﺎﺏ ﺍﻹﻧﺑﻌﺎﺝ ﺍﻟﺣﻘﻳﻘﻲ ﻋﻥ ﻁﺭﻳﻖ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻹﻧﺟﻠﻳﺯﻳﺔ ﺃﻭ‬
‫ﺃﻱ ﻣﻭﺍﺻﻔﺎﺕ ﺃﺧﺭﻯ ﻭﻛﺫﻟﻙ ﻳﺟﺏ ﺣﺳﺎﺏ ﺗﺄﺛﻳﺭ ﺍﻹﻧﺑﻌﺎﺝ ﻋﻠﻰ ﺍﻟﻣﺩﻯ‬
‫ﺍﻟﻁﻭﻳﻝ‪.‬‬
‫• ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﻘﻭﺍﻋﺩ ﺍﻟﻣﺭﻛﺑﺔ ‪ /‬ﻗﻭﺍﻋﺩ ﺍﻟﺧﻭﺍﺯﻳﻖ ‪ /‬ﺍﻟﺣﺻﻳﺭﺓ ‪ /‬ﻳﺟﺏ ﺃﻥ‬
‫ﺗﺅﺧﺫ ﻓﻲ ﺍﻋﺗﺑﺎﺭﺍﺕ ﺍﻟﺗﺻﻣﻳﻡ ﻻﻣﺭﻛﺯﻳﺔ ﺍﻻﺣﻣﺎﻝ ﺑﺎﻟﻧﺳﺑﺔ ﻟﻣﺭﻛﺯ‬
‫ﺍﻻﺳﺎﺱ‪.‬‬
‫• ﻓﻲ ﺣﺎﻟﺔ ﺍﻷﺳﺎﺳﺎﺕ ﺍﻟﺧﺎﺯﻭﻗﻳﺔ ﻳﺟﺏ ﺃﻥ ﻳﻛﻭﻥ ﺃﻗﻝ ﻣﺳﺎﻓﺔ ﺑﻳﻥ ﻣﺭﺍﻛﺯ‬
‫ﺍﻟﺧﻭﺍﺯﻳﻖ ﻋﻥ ‪ 2.5‬ﻗﻁﺭ ﺍﻟﺧﺎﺯﻭﻕ ﺃﻭ ﻛﻣﺎ ﻳﺫﻛﺭ ﻓﻲ ﺗﻘﺭﻳﺭ ﺍﻟﺗﺭﺑﺔ‪.‬‬
‫• ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺧﻭﺍﺯﻳﻖ ﺃﻭ ﺍﻟﺣﺻﻳﺭﺓ ﻳﺟﺏ ﺃﺧﺫ ﺍﻟﻘﻭﺓ ﺍﻷﻓﻘﻳﺔ ﺍﻟﻧﺎﺗﺟﺔ ﻋﻥ‬
‫ﺃﺣﻣﺎﻝ ﺍﻟﺭﻳﺎﺡ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ ﻣﻊ ﺍﻷﺣﻣﺎﻝ ﺍﻟﻌﺎﺩﻳﺔ‪.‬‬
‫• ﻓﻲ ﺣﺎﻟﺔ ﺇﺳﺗﺧﺩﺍﻡ ﺍﻟﻁﺭﻕ ﺍﻟﻳﺩﻭﻳﺔ ﻟﺣﺳﺎﺏ ﺍﻟﺑﻼﻁﺎﺕ ﺍﻟﻣﺳﻁﺣﺔ ﺃﻭ‬
‫ﺃﺳﺎﺳﺎﺕ ﺍﻟﺣﺻﻳﺭ ﻓﺈﻥ ﻣﺳﺎﻓﺎﺕ ﺍﻷﻋﻣﺩﺓ ﻭﻁﺭﻳﻘﺔ ﺗﻭﺯﻳﻌﻬﺎ ﻳﺟﺏ ﺃﻥ‬
‫ﺗﺗﺑﻊ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ ﺃﻭ ﺍﻷﻣﺭﻳﻛﻳﺔ ﻭﺇﻻ ﻳﺟﺏ ﺗﺣﻠﻳﻠﻬﺎ ﻋﻥ‬
‫ﻁﺭﻳﻖ ﺍﻟﻌﻧﺎﺻﺭ ﺍﻟﻼﻧﻬﺎﺋﻳﺔ‪.‬‬
‫• ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺑﻼﻁﺎﺕ ﺍﻟﻣﺳﻁﺣﺔ ﺍﻟﺗﻰ ﺳﻣﻛﻬﺎ‪ 15‬ﺳﻡ ﺣﺗﻰ‪20‬ﺳﻡ ﻓﺈﻥ ﺃﺣﻣﺎﻝ‬
‫ﺍﻟﺣﻭﺍﺋﻁ ﻳﺟﺏ ﺇﻋﺗﺑﺎﺭﻫﺎ ﻋﻠﻰ ﺇﻧﻬﺎ ﺃﺣﻣﺎﻝ ﻣﺭﻛﺯﺓ ﻋﻠﻰ ﺍﻟﻭﺻﻼﺕ‪.‬‬

‫ﺍﻟﻣﻌﻠﻭﻣﺎﺕ ﺍﻟﻣﻁﻠﻭﺏ ﺗﻭﺍﻓﺭﻫﺎ ﻓﻲ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻹﻧﺷﺎﺋﻳﺔ‬ ‫•‬

‫ﻟﻠﻔﻳﻼﺕ‬
‫ﺗﻭﺿﻳﺢ ﺟﻬﺩ ﺍﻟﺗﺭﺑﺔ ﻭﻋﻣﻖ ﺍﻷﺳﺎﺱ ﻭﺇﺣﻼﻝ ﺍﻟﺗﺭﺑﺔ ﺇﻥ ﻭﺟﺩ‪.‬‬ ‫•‬
‫ﻣﺧﻁﻁﺎﺕ ﺍﻟﻣﻼﺣﻅﺎﺕ ﺍﻟﻌﺎﻣﺔ ﻳﺟﺏ ﺃﻥ ﺗﺗﺿﻣﻥ ﺍﻟﺗﻔﺎﺻﻳﻝ ﺍﻟﻌﺎﻣﺔ ﻭ ﻧﻭﻋﻳﺔ‬ ‫•‬
‫ﻭﺟﻬﺩ ﺍﻟﺧﺭﺳﺎﻧﺔ ﻭﺍﻟﺣﺩﻳﺩ‪ ...‬ﺇﻟﺦ ‪.‬‬
‫ﻣﺧﻁﻁ ﻟﻣﺣﺎﻭﺭ ﺍﻷﻋﻣﺩﺓ ﻟﺗﻭﺿﻳﺢ ﺍﻟﺗﻘﻠﻳﻝ ﻓﻲ ﺣﺟﻡ ﻣﻘﺎﺳﺎﺕ ﺍﻷﻋﻣﺩﺓ‬ ‫•‬
‫ﻭﺃﺣﻣﺎﻝ ﺍﻟﻘﻭﺍﻋﺩ ‪.‬‬
‫ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻟﺗﻔﺻﻳﻠﻳﺔ ﻟﻸﺳﺎﺳﺎﺕ ﻭ ﺍﻟﺟﺳﻭﺭ ﺍﻟﺭﺍﺑﻁﺔ ﻭ ﺍﻟﺟﺳﻭﺭ‬ ‫•‬
‫ﺍﻷﺭﺿﻳﺔ ﻭﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻣﺗﻛﺭﺭﺓ ﻭ ﺍﻟﺳﻁﺢ ﻭﺟﺩﺍﻭﻝ ﺣﺩﻳﺩ ﺍﻟﺗﺳﻠﻳﺢ ﻭ‬
‫ﺭﺳﻭﻣﺎﺕ ﺗﻔﺻﻳﻠﻳﺔ ﻟﻠﺳﻭﺭ ﻭﺩﻳﻛﻭﺭﺍﺕ ﺍﻟﻭﺍﺟﻬﺎﺕ ‪.‬‬
‫ﺭﺳﻭﻣﺎﺕ ﺗﻔﺻﻳﻠﻳﺔ ﻟﺣﺩﻳﺩ ﺗﺳﻠﻳﺢ ﺍﻟﺳﻼﻟﻡ ‪.‬‬ ‫•‬
‫ﺭﺳﻭﻣﺎﺕ ﺗﻔﺻﻳﻠﻳﺔ ﻟﺗﻭﺿﻳﺢ ﺣﺩﻳﺩ ﺍﻟﺗﺳﻠﻳﺢ ﺣﻭﻝ ﺍﻟﻔﺗﺣﺎﺕ ﻭﺍﻟﺟﻭﺍﻧﺏ ﻭ‬ ‫•‬
‫ﺍﻷﻋﺗﺎﺏ ‪.‬‬
‫ﺗﻭﺿﻳﺢ ﻋﺩﺩ ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻣﺻﻣﻡ ﻋﻠﻳﻬﺎ ﺍﻟﻘﻭﺍﻋﺩ ﻭﻳﺟﺏ ﺃﻥ ﻳﻛﻭﻥ ﻧﻔﺱ‬ ‫•‬
‫ﺍﻟﻌﺩﺩ ﺍﻟﻣﻌﺗﻣﺩ ﻓﻲ ﺍﻟﻣﻭﺍﻓﻘﺔ ﺍﻹﺑﺗﺩﺍﺋﻳﺔ ‪.‬‬

‫ﺍﻟﻣﻌﻠﻭﻣﺎﺕ ﺍﻟﻣﻁﻠﻭﺏ ﺗﻭﺍﻓﺭﻫﺎ ﻓﻲ ﺍﻟﻣﺫﻛﺭﺓ ﺍﻟﺣﺳﺎﺑﻳﺔ‬ ‫•‬

‫ﻟﻠﻔﻳﻼﺕ‬
‫ﺗﻘﺭﻳﺭ ﺍﻟﺗﺭﺑﻳﺔ ﺍﻷﺻﻠﻲ‪.‬‬ ‫•‬
‫ﻓﻬﺭﺱ ﺑﻪ ﻋﺩﺩ ﺍﻟﺻﻔﺣﺎﺕ ﻭﻣﺎ ﺗﺣﺗﻭﻳﻪ ﺍﻟﻣﺫﻛﺭﺓ ﻣﻥ ﺍﻟﻣﻔﺭﻭﺽ ﺍﻷﺳﺎﺳﻳﺔ‬ ‫•‬
‫ﻟﻠﺗﺻﻣﻳﻡ ﻣﻊ ﺟﻬﺩ ﺍﻟﺧﺭﺳﺎﻧﺔ ﻭﺍﻟﺣﺩﻳﺩ ﻭﻋﺩﺩ ﺍﻟﻁﻭﺍﺑﻖ ﺍﻟﻣﺻﻣﻣﺔ ﻋﻠﻳﻬﺎ‬
‫ﺍﻟﻘﻭﺍﻋﺩ‪ ...‬ﺇﻟﺦ‪.‬‬
‫ﺣﺳﺎﺑﺎﺕ ﺗﻔﺻﻳﻠﻳﺔ ﻷﺣﻣﺎﻝ ﺍﻷﻋﻣﺩﺓ ‪ .‬ﻭﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﺇﻧﺗﻅﺎﻡ ﺍﻟﻣﺳﺎﻓﺎﺕ‬ ‫•‬
‫ﺑﻳﻥ ﺍﻷﻋﻣﺩﺓ ﻳﺟﺏ ﺇﺳﺗﺧﺩﺍﻡ ﻁﺭﻳﻘﺔ ﺭﺩ ﺍﻟﻔﻌﻝ ﻟﺣﺳﺎﺏ ﺍﻷﺣﻣﺎﻝ ‪.‬‬
‫• ﺃﺣﻣﺎﻝ ﺍﻷﻋﻣﺩﺓ ﻳﺟﺏ ﺃﻥ ﺗﺗﺿﻣﻥ ﺍﻟﻭﺯﻥ ﺍﻟﺫﺍﺗﻲ ﻟﻠﺟﺳﻭﺭ ﻭ ﺍﻟﺣﻭﺍﺋﻁ‬
‫ﻭﺍﻷﻋﻣﺩﺓ ﻭﺳﻭﺭ ﺍﻟﺳﻁﺢ ﻭﺑﻳﺕ ﺍﻟﺳﻠﻡ ﻭ ﺃﺣﻣﺎﻝ ﺧﺯﺍﻧﺎﺕ ﺍﻟﻣﻳﺎﻩ ﻭﻋﻧﺩ‬
‫ﺍﻟﺗﺩﻗﻳﻖ ﻋﻠﻰ ﺇﺟﻬﺎﺩ ﺍﻟﻘﻭﺍﻋﺩ ﻳﺟﺏ ﺃﺧﺫ ﻭﺯﻥ ﺍﻟﺗﺭﺑﺔ ﻓﻭﻕ ﻣﻧﺳﻭﺏ ﺍﻷﺭﺽ‬
‫ﺍﻟﻁﺑﻳﻌﻳﺔ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ ﻣﻊ ﺫﻛﺭ ﺃﺣﻣﺎﻝ ﺍﻟﻘﻭﺍﻋﺩ ﻋﻠﻰ ﻣﺧﻁﻁ ﺍﻷﻋﻣﺩﺓ ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺭﺑﻁ ﺍﻟﻘﻭﺍﻋﺩ ﺑﺟﺳﻭﺭ ﺭﺍﺑﻁﺔ ﻳﺟﺏ ﺃﺧﺫ ﺍﻷﺣﻣﺎﻝ ﺍﻹﺿﺎﻓﻳﺔ ﻧﺗﻳﺟﺔ‬ ‫•‬
‫ﺍﻟﻼﻣﺭﻛﺯﻳﺔ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺍﻷﻋﻣﺩﺓ ﺍﻟﻁﻭﻳﻠﺔ ﻳﺟﺏ ﺃﺧﺫ ﺍﻟﻣﻌﺯﻭﻡ ﺍﻹﺿﺎﻓﻳﺔ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ‪.‬‬ ‫•‬
‫ﻳﺟﺏ ﺇﺭﻓﺎﻕ ﻣﻧﺣﻧﻳﺎﺕ ﺍﻟﻌﺯﻭﻡ ﻭﺍﻟﻘﺹ ﻭﺍﻟﻘﻭﻯ ﻣﻊ ﺣﺳﺎﺑﺎﺕ ﺍﻟﺣﺩﻳﺩ‬ ‫•‬
‫ﻟﺟﻣﻳﻊ ﺍﻟﺟﺳﻭﺭ ‪ .‬ﻭﻳﻛﻭﻥ ﻣﺭﺟﻊ ﻫﺫﻩ ﺍﻟﻣﻧﺣﻳﺎﺕ ﺍﻟﻣﺣﺎﻭﺭ ﺍﻟﺭﺋﻳﺳﻳﺔ‬
‫ﺑﺎﻟﻣﺧﻁﻁﺎﺕ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﻪ ﻭﺟﻭﺩ ﺃﻋﻣﺩﺓ ﻣﺩﻓﻭﻧﺔ ﻋﻠﻰ ﺍﻟﺟﺳﻭﺭ ﺍﻟﺗﺩﻗﻳﻖ ﻋﻠﻰ ﺍﻹﻧﺑﻌﺎﺝ ﻛﻣﺎ‬ ‫•‬
‫ﻳﺟﺏ ﺍﻟﺗﺩﻗﻳﻖ ﻋﻠﻰ ﺍﻟﻛﻣﺭﻩ ﻣﻥ ﻧﺎﺣﻳﻪ ﺍﻹﺟﻬﺎﺩ ﻭﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﺟﺳﻭﺭ‬
‫ﺍﻟﻣﺩﻓﻭﻧﺔ ﻭﺍﻟﺑﻼﻁﺎﺕ ﺍﻟﺗﻰ ﻁﻭﻟﻬﺎ ﺃﻛﺛﺭ ﻣﻥ ‪ 6‬ﻡ ﻳﺟﺏ ﺣﺳﺎﺏ ﺍﻹﻧﺑﻌﺎﺝ‬
‫ﺍﻟﺣﻘﻳﻘﻲ ﻋﻥ ﻁﺭﻳﻖ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻹﻧﺟﻠﻳﺯﻳﺔ ﺃﻭ ﻏﻳﺭﻫﺎ ﻭﺃﻳﺿﺎ ﻳﺟﺏ‬
‫ﺣﺳﺎﺏ ﺗﺄﺛﻳﺭ ﺍﻹﻧﺑﻌﺎﺝ ﻋﻠﻰ ﻣﺩﻯ ﺍﻟﻁﻭﻳﻝ ‪.‬‬
‫ﻳﺟﺏ ﺗﻘﺩﻳﻡ ﺣﺳﺎﺑﺎﺕ ﻣﻧﻔﺻﻠﺔ ﻟﻠﺑﻼﻁﺎﺕ ﻭﺍﻟﺟﺳﻭﺭ ﺍﻟﺣﺎﻣﻠﺔ ﻟﺧﺯﺍﻥ ﺍﻟﻣﺎء ‪.‬‬ ‫•‬
‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﻘﻭﺍﻋﺩ ﺍﻟﻣﺭﻛﺑﺔ ﻳﺟﺏ ﺍﻷﺧﺫ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ ﻻ ﻣﺭﻛﺯﻳﺔ ﺍﻷﺣﻣﺎﻝ‬ ‫•‬
‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻣﺭﻛﺯ ﺍﻷﺳﺎﺱ ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺇﺳﺗﺧﺩﺍﻡ ﺍﻟﻁﺭﻕ ﺍﻟﻳﺩﻭﻳﺔ ﻟﺣﺳﺎﺏ ﺍﻟﺑﻼﻁﺎﺕ ﺍﻟﻣﺳﻁﺣﺔ ﻓﺈﻥ‬ ‫•‬
‫ﻣﺳﺎﻓﺎﺕ ﺍﻷﻋﻣﺩﺓ ﻭﻁﺭﻳﻘﺔ ﺗﻭﺯﻳﻌﻬﺎ ﻳﺟﺏ ﺃﻥ ﺗﺗﺑﻊ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ‬
‫ﺃﻭ ﺍﻷﻣﺭﻳﻛﻳﺔ ﻭﻻ ﻳﺟﻭﺯ ﺗﺣﻠﻳﻠﻬﺎ ﻋﻥ ﻁﺭﻕ ﺍﻟﻌﻧﺎﺻﺭ ﺍﻟﻼﻧﻬﺎﺋﻳﺔ ‪.‬‬

‫ﺍﻟﻣﻌﻠﻭﻣﺎﺕ ﺍﻟﻣﻁﻠﻭﺑﺔ ﺗﻭﺍﻓﺭﻫﺎ ﻓﻲ ﺍﻟﻣﺧﻁﻁﺎﺕ ﺍﻹﻧﺷﺎﺋﻳﺔ‬ ‫•‬

‫ﻟﻠﻣﺳﺗﻭﺩﻋﺎﺕ ﺍﻟﻣﻌﺩﻧﻳﺔ‬
‫• ﺗﻭﺿﻳﺢ ﺟﻬﺩ ﺍﻟﺗﺭﺑﺔ ﻭﻋﻣﻖ ﺍﻷﺳﺎﺱ ﻭﺇﺣﻼﻝ ﺍﻟﺗﺭﺏ ﺇﻥ ﻭﺟﺩ‬
‫• ﻣﺧﻁﻁﺎﺕ ﺍﻟﻣﻼﺣﻅﺎﺕ ﺍﻟﻌﺎﻣﺔ ﻳﺟﺏ ﺃﻥ ﺗﺗﺿﻣﻥ ﺍﻟﺗﻔﺎﺻﻳﻝ ﺍﻟﻌﺎﻣﺔ‬
‫ﻭﻧﻭﻋﻳﺔ ﻭﺟﻬﺩ ﺍﻟﺧﺭﺳﺎﻧﺔ ﻭﺣﺩﻳﺩ ﺍﻟﺗﺳﻠﻳﺢ ﺍﻹﻧﺷﺎﺋﻲ ﻭﺍﻟﺣﺩﻳﺩ‬
‫ﻭﺍﻟﻣﺳﺎﻣﻳﺭ ﻭﺍﻟﻭﺻﻼﺕ‪.‬‬
‫‪ .‬ﺗﺣﺩﻳﺩ ﺣﺩﻭﺩ ﻗﻁﻌﺔ ﺍﻷﺭﺽ ﻋﻠﻰ ﻣﺧﻁﻁ ﺍﻟﻘﻭﺍﻋﺩ ﻣﻊ ﺗﻭﺿﻳﺢ ﺑﺭﻭﺯ‬
‫ﺍﻟﻘﻭﺍﻋﺩ ﺧﺎﺭﺝ ﻗﻁﻌﺔ ﺍﻷﺭﺽ ‪.‬‬
‫• ﻣﺳﺎﻗﻁ ﺃﻓﻘﻳﺔ ﻟﻣﺣﺎﻭﺭ ﺍﻷﻋﻣﺩﺓ ﻭﻣﺳﺎﻣﻳﺭ ﺍﻟﺗﻭﺻﻳﻝ ﻣﻊ ﺗﻭﺿﻳﺢ‬
‫ﻣﻘﺎﺳﺎﺕ ﺍﻷﻋﻣﺩﺓ ﻭﺃﺣﻣﺎﻝ ﺍﻟﻘﻭﺍﻋﺩ ﻭﻳﺗﺿﻣﻥ ﺃﻳﺿﺎ ﻋﺯﻭﻡ ﺍﻟﺭﻳﺎﺡ ‪.‬‬
‫• ‪.‬ﻣﺧﻁﻁﺎﺕ ﺗﻔﺻﻳﻠﻳﺔ ﻟﻠﻘﻭﺍﻋﺩ ﻭﺍﻟﺟﺳﻭﺭ ﺍﻟﺭﺍﺑﻁﺔ ﻭﺍﻟﺟﺳﻭﺭ‬
‫ﺍﻷﺭﺿﻳﺔ ﻭﻁﺎﺑﻖ ﺍﻟﻣﻳﺯﺍﻧﻳﻥ ﻭﺍﻟﺳﻁﺢ ﻭﺟﺩﺍﻭﻝ ﺍﻟﺣﺩﻳﺩ ﻭﺳﻭﺭ‬
‫ﺍﻟﺳﻁﺢ ﻭﺗﻔﺎﺻﻳﻝ ﺍﻟﺩﻳﻛﻭﺭﺍﺕ ‪.‬‬
‫• ﻣﺧﻁﻁﺎﺕ ﺍﻹﻁﺎﺭ ﺍﻹﻧﺷﺎﺋﻲ ﻣﺗﺿﻣﻧﺔ ﻣﻘﺎﺳﺎﺕ ﺍﻷﻋﻣﺩﺓ ﺍﻟﺣﺩﻳﺩﻳﺔ ﻣﻊ‬
‫ﺍﻟﺟﺳﻭﺭ ﺍﻟﺣﺩﻳﺩﻳﺔ ﻭﻣﻘﺎﺳﺎﺗﻬﺎ ﻭﺗﻔﺎﺻﻳﻝ ﻛﺎﻣﻠﺔ ﻟﻠﻭﺻﻼﺕ‪.‬‬
‫• ﻣﺧﻁﻁﺎﺕ ﻟﻠﺳﻁﺢ ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺟﺳﻭﺭ ﺭﺍﺑﻁﺔ )‪( PURLIN‬‬
‫ﻭﻭﺻﻼﺗﻬﺎ ﻣﻊ ﺣﺩﻳﺩ ﺭﺑﻁ ﺍﻟﺳﻁﺢ‪.‬‬
‫• ﻣﺧﻁﻁ ﺗﻔﺻﻳﻠﻲ ﻟﻠﺳﻼﻟﻡ ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩﻫﺎ‪.‬‬
‫• ﻟﻣﻘﺎﻭﻣﺔ ﺍﻟﺭﻳﺎﺡ ﻳﺗﻡ ﻭﺿﻊ ﺍﻟﺣﺩﻳﺩ ﺍﻟﺭﺍﺑﻁ ﺍﻟﺭﺃﺳﻲ ﺑﻳﻥ ﺍﻷﻋﻣﺩﺓ‬
‫ﻣﺧﻁﻁﺎﺕ ﺍﻟﻣﻘﺎﻁﻊ ﻣﻊ ﺗﻭﺿﻳﺢ ﺍﻟﺟﺳﻭﺭ ﺍﻟﻔﺎﺻﻠﺔ ﺑﻳﻥ ﺍﻟﻁﺎﺑﻭﻕ‬ ‫•‬
‫ﻋﻠﻰ ﺃﻥ ﻻ ﺗﺯﻳﺩ ﻣﺳﺎﺣﺔ ﺍﻟﻁﺎﺑﻭﻕ ﻋﻥ )‪15‬ﻡ ‪ ( 2‬ﺑﻳﻥ ﺍﻟﺟﺳﻭﺭ‪.‬‬

‫ﺍﻟﻣﻌﻠﻭﻣﺎﺕ ﺍﻟﻣﻁﻠﻭﺏ ﺗﻭﺍﻓﺭﻫﺎ ﻓﻲ ﺍﻟﻣﺫﻛﺭﺓ ﺍﻟﺣﺳﺎﺑﻳﺔ‬ ‫•‬

‫ﻟﻠﻣﺳﺗﻭﺩﻋﺎﺕ ﺍﻟﻣﻌﺩﻧﻳﺔ‬
‫ﺗﻘﺭﻳﺭ ﺍﻟﺗﺭﺑﺔ‪.‬‬ ‫•‬
‫ﻓﻬﺭﺱ ﻣﻊ ﻓﺭﻭﺽ ﺍﻟﺗﺻﻣﻳﻡ ﺍﻷﺳﺎﺳﻳﺔ ﻟﻸﺣﻣﺎﻝ ﻭﺇﺟﻬﺎﺩ ﺍﻟﺧﺭﺳﺎﻧﺔ‬ ‫•‬
‫ﻭﺇﺟﻬﺎﺩ ﺣﺩﻳﺩ ﺍﻟﺗﺳﻠﻳﺢ ﻭﺇﺟﻬﺎﺩ ﺣﺩﻳﺩ ﺍﻟﻣﺳﺗﻭﺩﻋﺎﺕ ﺍﻟﻣﻌﺩﻧﻳﺔ‬
‫ﻭﺇﺟﻬﺎﺩ ﺍﻟﻣﺳﺎﻣﻳﺭ ﻭﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺗﻰ ﻳﺟﺏ ﺍﻟﺭﺟﻭﻉ ﺇﻟﻳﻬﺎ‪.‬‬
‫ﺣﺳﺎﺑﺎﺕ ﺗﻔﺻﻳﻠﻳﺔ ﻷﺣﻣﺎﻝ ﺍﻷﻋﻣﺩﺓ ﺗﻌﺗﻣﺩ ﻋﻠﻰ ﺍﻟﺣﺎﻻﺕ ﺍﻟﺣﺭﺟﺔ‬ ‫•‬
‫ﻟﻸﺣﻣﺎﻝ ﻭﺍﻟﺗﺩﻗﻳﻖ ﻋﻠﻰ ﺇﺟﻬﺎﺩ ﺍﻟﺗﺭﺑﺔ ﻭﻳﺗﻡ ﺍﻷﺧﺫ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ‬
‫ﻭﺯﻥ ﺍﻟﺗﺭﺑﺔ ﻓﻭﻕ ﻣﻧﺳﻭﺏ ﺍﻷﺭﺽ ﺍﻟﻁﺑﻳﻌﻳﺔ ﻭﻳﺗﻡ ﺗﺣﺩﻳﺩ ﺃﺣﻣﺎﻝ‬
‫ﺍﻟﻘﻭﺍﻋﺩ ﻋﻠﻰ ﻣﺧﻁﻁ ﺍﻷﻋﻣﺩﺓ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﺟﺳﻭﺭ ﺭﺍﺑﻁﺔ ﺑﻳﻥ ﺍﻟﻘﻭﺍﻋﺩ ﻳﺟﺏ ﺍﻷﺧﺫ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ‬ ‫•‬
‫ﺍﻟﺣﻣﻝ ﺍﻹﺿﺎﻓﻲ ﻧﺗﻳﺟﺔ ﺍﻟﻼﻣﺭﻛﺯﻳﺔ‪.‬‬
‫ﻳﺟﺏ ﺗﻘﺩﻳﻡ ﻣﻧﺣﻧﻳﺎﺕ ﺍﻷﺣﻣﺎﻝ ﻭﺍﻟﻌﺯﻭﻡ ﻭﺍﻟﻘﺹ ﻭﺍﻟﺣﺳﺎﺑﺎﺕ ﻟﻛﻝ‬ ‫•‬
‫ﺍﻟﻬﻳﺎﻛﻝ ﺍﻟﺭﺋﻳﺳﻳﺔ ﻛﻣﺎ ﻳﺟﺏ ﺍﻟﺗﺩﻗﻳﻖ ﻋﻠﻰ ﺍﻹﻧﺑﻌﺎﺝ ﻟﻛﻝ ﺍﻟﻌﻧﺎﺻﺭ‬
‫ﺍﻟﺣﺭﺟﺔ‪.‬‬
‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﺑﺎﻛﻳﺔ ﺍﻟﺗﻲ ﺑﻬﺎ ﺍﻟﺣﺩﻳﺩ ﺍﻟﺭﺍﺑﻁ )‪ (bracing‬ﻳﺗﻡ ﺍﻟﺗﺩﻗﻳﻖ‬ ‫•‬
‫ﻋﻠﻰ ﺍﻹﻧﻘﻼﺏ‪.‬‬
‫ﺑﺎﻟﻧﺳﺑﺔ ﻟﻠﻘﻭﺍﻋﺩ ﺍﻟﻣﺭﻛﺑﺔ ﻳﺟﺏ ﺍﻷﺧﺫ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ ﻻﻣﺭﻛﺯﻳﺔ‬ ‫•‬
‫ﺍﻷﺣﻣﺎﻝ ﻋﻠﻳﻬﺎ‪.‬‬
‫ﻳﺟﺏ ﺇﻋﺗﻣﺎﺩ ﻓﺭﻭﺽ ﺍﻟﺗﺻﻣﻳﻡ ﺍﻟﺻﺎﺩﺭﺓ ﻣﻥ ﺍﻟﺑﻠﺩﻳﺔ ﻟﺗﺻﻣﻳﻡ‬ ‫•‬
‫ﺍﻟﻣﺳﺗﻭﺩﻋﺎﺕ ﺍﻟﻣﻌﺩﻧﻳﺔ‪.‬‬
‫ﻳﺟﺏ ﺃﻥ ﻳﺗﻡ ﺗﺻﻣﻳﻡ ﺍﻟﻣﻧﺷﺂﺕ ﻭﺍﻟﻣﺑﺎﻧﻲ ﻭﻓﻖ ﺍﻟﻛﻭﺩﺍﺕ‬ ‫•‬
‫ﻭﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻘﻳﺎﺳﻳﺔ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ ﺃﻭ ﺍﻟﻛﻭﺩﺍﺕ ﺍﻷﺧﺭﻯ ﺍﻟﻣﻌﺗﻣﺩﺓ‬
‫ﻟﺩﻯ ﺍﻟﺑﻠﺩﻳﺔ ﺃﻭ ﻣﺎ ﻳﺳﺗﺟﺩ ﻋﻠﻳﻬﺎ ﻣﻣﺎ ﻳﺣﻘﻖ ﻣﺗﻁﻠﺑﺎﺕ ﻫﺫﻩ ﺍﻟﻼﺋﺣﺔ‪.‬‬

‫ﻛﻭﺩﺍﺕ ﺍﻷﺣﻣﺎﻝ ﺍﻟﺣﻳﺔ ﻭﺍﻟﻣﻳﺗﺔ ﻋﻠﻰ ﺍﻟﻣﺑﺎﻧﻲ‬ ‫•‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ ‪ 6399-‬ﺍﻟﺟﺯء ﺍﻷﻭﻝ‪BS 1996 ) 1996‬‬
‫‪ ( PARTK 6399‬ﻣﻊ ﻣﻼﺣﻅﺔ ﺍﻹﺳﺗﺛﻧﺎءﺍﺕ ﺍﻟﺗﺎﻟﻳﺔ ﻣﻣﺎ ﻭﺭﺩ ﻓﻲ ﺍﻟﻛﻭﺩ ﺍﻟﻣﺫﻛﻭﺭ‬
‫ﺃﻋﻼﻩ‪:‬‬
‫)‪5‬ﻛﻳﻠﻭ‬ ‫ﺃﻥ ﻻ ﻳﻘﻝ ﺍﻟﺣﻣﻝ ﺍﻟﺣﻲ ﻋﻠﻰ ﻁﺎﺑﻖ ﺍﻟﻣﻳﺯﺍﻧﻳﻥ ﻋﻥ‬ ‫•‬
‫ﻧﻳﻭﺗﻥ‪/‬ﻣﺗﺭ‪ (5KN/M2) ( 2‬ﻓﻲ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺗﺟﺎﺭﻳﺔ ﻭﺍﻟﺻﻧﺎﻋﻳﺔ‪.‬‬
‫ﺃﻥ ﻻ ﻳﻘﻝ ﺍﻟﺣﻣﻝ ﺍﻟﺣﻲ ﻋﻥ )‪3.50‬ﻛﻳﻠﻭ ﻧﻳﻭﺗﻥ‪ /‬ﻣﺗﺭ‪(3.5M2) ( 2‬‬ ‫•‬
‫ﻓﻲ ﻣﺑﺎﻧﻲ ﻣﻭﺍﻗﻑ ﺍﻟﺳﻳﺎﺭﺍﺕ‪.‬‬
‫ﺃﻥ ﻻ ﻳﻘﻝ ﺍﻟﺣﻣﻝ ﺍﻟﺣﻲ ﻓﻲ ﺗﺻﻣﻳﻡ ﺍﻟﺑﻼﻁﺎﺕ ﺍﻟﻔﻁﺭﻳﺔ )‪(FLAT SLAB‬‬ ‫•‬
‫ﻭﺍﻟﺑﻼﻁﺎﺕ ﺳﺎﺑﻘﺔ ﺍﻹﺟﻬﺎﺩ )‪ (POST TENSIONING‬ﻋﻥ ‪ 3‬ﻛﻳﻠﻭ‬
‫ﻧﻳﻭﺗﻥ ‪ /‬ﻣﺗﺭ)‪2 (3KN/M2‬ﻓﻲ ﺟﻣﻳﻊ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺗﻲ ﻗﺩ ﺗﺗﻌﺭﺽ ﻷﺣﻣﺎﻝ‬
‫ﺣﻳﺔ ﺃﻗﻝ ﻣﻥ ﻫﺫﺍ ﺍﻟﻣﻘﺩﺍﺭ ﻛﻣﺎ ﻳﺟﺏ ﺇﺿﺎﻓﺔ ﺃﺣﻣﺎﻝ ﺍﻟﺟﺩﺭﺍﻥ ﺇﻟﻰ ﺍﻷﺣﻣﺎﻝ‬
‫ﺍﻟﺣﻳﺔ‪.‬‬

‫ﻛﻭﺩﺍﺕ ﺃﺣﻣﺎﻝ ﺍﻟﺭﻳﺎﺡ‬ ‫•‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ – ‪ 6399‬ﺍﻟﺟﺯء ﺍﻟﺛﺎﻧﻲ – ﻋﺎﻡ ‪1995‬ﺃﻭ ﺍﻟﻛﻭﺩ‬
‫ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ – ‪ 3‬ﺍﻟﻔﺻﻝ ﺍﻟﺧﺎﻣﺱ – ﺍﻟﺟﺯء ﺍﻟﺛﺎﻧﻲ ‪ -1972‬ﻣﻊ ﻣﻼﺣﻅﺔ‬
‫ﺳﺭﻋﺔ ﺍﻟﺭﻳﺎﺡ ﻓﻲ ﺇﻣﺎﺭﺓ‬
‫ﺃﻡ ﺍﻟﻘﻳﻭﻳﻥ ﻫﻲ‬
‫‪(for Bs-6399/1995 vb=24m/s) (for CP3 Chapter Vv-part2‬‬
‫)‪vb=45m/s‬‬

‫ﻛﻭﺩﺍﺕ ﺍﻷﺣﻣﺎﻝ ﺍﻟﺣﻳﺔ ﻋﻠﻰ ﺍﻟﺳﻘﻑ‬ ‫•‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ – ‪ 6399‬ﺍﻟﺟﺯء ﺍﻟﺛﺎﻟﺙ ‪ -1988‬ﻭﻋﻠﻰ ﺃﻥ ﻳﺭﺍﻋﻲ‬
‫ﻓﻲ ﺍﻟﺣﺳﺎﺑﺎﺕ ﺍﻟﺗﺄﺛﻳﺭﺍﺕ ﺍﻟﺩﻳﻧﺎﻣﻳﻛﻳﺔ ﻭﺗﺭﻛﻳﺯ ﺍﻷﺣﻣﺎﻝ ﺍﻟﻧﺎﺟﻡ ﻋﻥ ﻣﺎﻛﻳﻧﺎﺕ‬
‫ﺃﺟﻬﺯﺓ ﺍﻟﺗﻛﻳﻳﻑ ﻭﺧﺯﺍﻧﺎﺕ ﺍﻟﻣﻳﺎﻩ ﻭﺗﺟﻣﻊ ﺍﻟﺭﻣﺎﻝ ﻋﻠﻰ ﺣﻭﺍﻑ ﺣﺎﺟﺯ ﺍﻟﺳﻁﺢ‬
‫ﻭﺗﺄﺛﺭ ﻫﺑﻭﻁ ﺍﻟﻁﺎﺋﺭﺍﺕ ﺍﻟﻌﻣﻭﺩﻳﺔ‪.‬‬
‫ﻛﻭﺩﺍﺕ ﺃﺣﻣﺎﻝ ﺍﻟﺯﻻﺯﻝ‬ ‫•‬
‫ﻳﺳﺗﺧﺩﻡ ﻛﻭﺩ ﺍﻟﺑﻧﺎء ﺍﻟﻧﻅﺎﻣﻲ ﺍﻷﻣﺭﻳﻛﻲ – ﺍﻟﻔﺻﻝ ﺍﻟﺳﺎﺩﺱ ﻋﺷﺭ‬ ‫•‬
‫ﺍﻷﻗﺳﺎﻡ ﻣﻥ ﺍﻟﺛﺎﻟﺙ ﺇﻟﻰ ﺍﻟﺧﺎﻣﺱ ‪-199 (code USA Chapter 16‬‬
‫)‪division 111 to V UBC uniform building‬ﻣﻊ ﻣﻼﺣﻅﺔ‬
‫ﺿﺭﻭﺭﺓ ﺍﻻﻟﺗﺯﺍﻡ ﺑﺎﻟﻘﻳﻡ ﺍﻟﺗﺎﻟﻳﺔ ﻟﻠﻌﻭﺍﻣﻝ ﺍﻟﺗﺎﻟﻳﺔ ﻟﻠﻌﻭﺍﻣﻝ ﺍﻟﻭﺍﺭﺩﺓ ﻓﻲ ﻣﻌﺎﺩﻟﺔ‬
‫ﺣﺳﺎﺏ ﺍﻟﻘﻭﻯ ﺍﻷﻓﻘﻳﺔ ﺍﻻﺳﺗﺎﺗﻳﻛﻳﺔ ﺍﻟﻣﻛﺎﻓﺋﺔ ﻷﻓﻌﺎﻝ ﺍﻟﺯﻻﺯﻝ‪.‬‬
‫ﻳﺳﺗﺧﺩﻡ ﻣﻌﺎﻣﻝ ﺍﻟﺷﺩﺓ ﻭﺍﻟﺫﻱ ﻳﻌﺗﻣﺩ ﻋﻠﻰ ﺍﻟﻣﻧﻁﻘﺔ ﻳﺅﺧﺫ ﻋﻠﻰ ﺃﺳﺎﺱ‬ ‫•‬
‫ﺍﻟﻣﻧﻁﻘﺔ‪(2A).‬‬
‫ﻳﺳﺗﺧﺩﻡ ﻣﻌﺎﻣﻝ ﺍﻟﺗﺭﺑﺔ ﻭﺍﻟﺫﻱ ﻳﺅﺧﺫ ﻋﻠﻰ ﺃﺳﺎﺱ ﺍﻟﺟﺩﻭﻝ ‪ 16-J‬ﺑﻛﻭﺩ‬ ‫•‬
‫ﺍﻟﺯﻻﺯﻝ ‪ UBC 1997‬ﻭﻓﻘﺎ ﻟﻶﺗﻲ‪:‬‬
‫ﺍﻟﻣﻌﺎﻣﻝ ‪ 5E‬ﺍﻟﻣﻧﺎﻁﻖ ﺍﻟﺳﺎﺣﻠﻳﺔ ﻭﺍﻟﻣﻧﺎﻁﻖ ﺍﻟﺗﻲ ﺗﻛﻭﻥ ﻓﻳﻬﺎ ﺍﻟﻣﻳﺎﻩ‬ ‫•‬
‫ﺍﻟﺟﻭﻓﻳﺔ ﻣﺭﺗﻔﻌﺔ ﻭﺍﻟﺗﺭﺑﺔ ﺍﻟﺭﻣﻠﻳﺔ ﺍﻟﻣﻔﻛﻛﺔ)‪. (SPTN <15‬‬

‫ﺍﻟﻣﻌﺎﻣﻼﺕ ‪ SA,SB,SC,SD‬ﻟﺑﺎﻗﻲ ﺍﻟﻣﻧﺎﻁﻖ ﻭﻓﻘﺎ ﻟﺗﺻﻧﻳﻑ ﺍﻟﺗﺭﺑﺔ‪.‬‬ ‫•‬

‫ﻛﻭﺩﺍﺕ ﺗﺻﻣﻳﻡ ﺍﻷﺳﺎﺳﺎﺕ‬ ‫•‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ ‪ 8004‬ﻋﺎﻡ‪. (Bs8004:1986) 1986‬‬

‫ﻛﻭﺩﺍﺕ ﻣﻧﺷﺂﺕ ﺍﻟﺧﺭﺳﺎﻧﺔ ﺍﻟﻣﺳﻠﺣﺔ ﺃﻭ ﺍﻟﺧﺭﺳﺎﻧﺔ ﺳﺎﺑﻘﺔ‬ ‫•‬

‫ﺍﻹﺟﻬﺎﺩ ﺃﻭ ﺍﻟﺧﺭﺳﺎﻧﺔ ﺍﻟﻌﺎﺩﻳﺔ‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ‪ 8110‬ﻟﻸﺟﺯﺍء ﺍﻟﺗﺎﻟﻳﺔ‪:‬‬
‫• ﺍﻟﺟﺯء ﺍﻷﻭﻝ – ﻟﻌﺎﻡ ‪ 1997-‬ﻟﻠﺗﺻﻣﻳﻡ ﻭﺍﻹﻧﺷﺎء‬
‫)‪(BS 8110:part:1- 1997‬‬
‫• ﺍﻟﺟﺯء ﺍﻟﺛﺎﻧﻲ – ﻟﻌﺎﻡ ‪ 1985-‬ﻟﻼﻋﺗﺑﺎﺭﺍﺕ ﺍﻟﺧﺎﺻﺔ ﺑﺎﻟﺗﺻﻣﻳﻡ‬
‫)‪(BS 8110:part:2 -1985‬‬
‫• ﺍﻟﺟﺯء ﺍﻟﺛﺎﻟﺙ ‪-‬ﻟﻌﺎﻡ – ‪ 1985‬ﺟﺩﻭﻝ ﻭﺭﺳﻭﻣﺎﺕ ﺍﻟﺗﺻﻣﻳﻡ‬
‫)‪(BS 8110:part:3- 1985‬‬

‫ﻛﻭﺩﺍﺕ ﺍﻟﻣﻧﺷﺂﺕ ﺍﻟﻣﻌﺩﻧﻳﺔ‬ ‫•‬


‫ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ ‪ 449-‬ﺍﻟﺟﺯء ﺍﻟﺛﺎﻧﻲ ‪ – 1969‬ﺃﻭ ﺍﻟﻛﻭﺩ‬ ‫•‬
‫ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ‪(5950).‬‬
‫ﺍﻟﺟﺯء ﺍﻷﻭﻝ – ﻟﻌﺎﻡ)‪1985 (BS 5950:part:1: 1985‬‬ ‫•‬
‫ﺍﻟﺟﺯء ﺍﻟﺛﺎﻧﻲ – ﻟﻌﺎﻡ)‪1985 (BS 5950:part:2: 1985‬‬ ‫•‬
‫ﺍﻟﺟﺯء ﺍﻟﺭﺍﺑﻊ – ﻟﻌﺎﻡ)‪1982 (BS 5950:part:4: 1982‬‬ ‫•‬
‫ﺍﻟﺟﺯء ﺍﻟﺧﺎﻣﺱ – ﻟﻌﺎﻡ)‪1987 (BS 5950:part:5: 1987‬‬ ‫•‬

‫ﻛﻭﺩﺍﺕ ﺍﻹﻧﺷﺎءﺍﺕ ﺍﻟﻣﻌﺩﻧﻳﺔ ﺍﻟﻣﺭﻛﺑﺔ‬ ‫•‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ‪117-‬ﺍﻟﺟﺯء ﺍﻷﻭﻝ‪1965‬‬

‫ﻛﻭﺩ ﺇﻧﺷﺎءﺍﺕ ﺍﻟﻁﺎﺑﻭﻕ ﺍﻟﺧﺭﺳﺎﻧﻲ‬ ‫•‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ ‪ 5628-‬ﺍﻟﺟﺯء ﺍﻷﻭﻝ ‪ – 1978/1985‬ﻭﺃﻳﺿﺎ‬
‫ﺍﻟﺟﺯء ﺍﻟﺛﺎﻟﺙ ﻣﻥ ﻧﻔﺱ ﺍﻟﻛﻭﺩ ﻟﻌﺎﻡ ‪. 1985‬‬

‫ﻛﻭﺩ ﺇﻧﺷﺎءﺍﺕ ﺍﻷﻟﻣﻭﻧﻳﻭﻡ‬ ‫•‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ)‪118- 1969- (CP118:1969‬‬

‫ﻛﻭﺩ ﺍﻹﻧﺷﺎءﺍﺕ ﺍﻟﺧﺷﺑﻳﺔ‬ ‫•‬


‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ ‪ 5268-‬ﺍﻟﺟﺯء ﺍﻟﺛﺎﻧﻲ‪- 1989‬ﻭﺍﻟﺟﺯء‬
‫ﺍﻟﺛﺎﻟﺙ‪- 1985‬‬
‫ﻛﻭﺩﺍﺕ ﺍﻟﺗﺻﺎﻣﻳﻡ ﺍﻷﺧﺭﻯ‬ ‫•‬
‫ﻳﻣﻛﻥ ﺇﻋﺩﺍﺩ ﺍﻟﺗﺻﺎﻣﻳﻡ ﺍﻹﻧﺷﺎﺋﻳﺔ ﺑﺎﻟﺭﺟﻭﻉ ﺇﻟﻰ ﻛﻭﺩﺍﺕ ﺑﻧﺎء ﺃﺧﺭﻯ‬
‫ﻏﻳﺭ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ ﺷﺭﻳﻁﺔ ﺍﻟﺣﺻﻭﻝ ﻋﻠﻰ ﻣﻭﺍﻓﻘﺔ ﺍﻟﺑﻠﺩﻳﺔ‪.‬‬

‫ﺍﻟﺗﺻﻣﻳﻡ ﺿﺩ ﺍﻹﻧﻬﻳﺎﺭ ﺍﻟﻣﺗﻭﺍﻟﻲ‬ ‫•‬


‫ﻟﻠﺣﻳﻠﻭﻟﺔ ﺩﻭﻥ ﺣﺻﻭﻝ ﺍﻹﻧﻬﻳﺎﺭ ﺍﻟﻣﺗﻭﺍﻟﻲ ﻭﻏﻳﺭ ﺍﻟﻣﺗﻛﺎﻓﺊ ﻓﻲ ﺟﻣﻳﻊ ﺍﻟﻣﻧﺷﺂﺕ‬
‫ﺫﺍﺕ ﺇﺭﺗﻔﺎﻉ ﺧﻣﺱ ﻁﻭﺍﺑﻖ ﺃﻭ ﺃﻛﺛﺭ )ﻳﺷﻣﻝ ﺫﻟﻙ ﻁﻭﺍﺑﻖ ﺍﻟﺳﺭﺩﺍﺏ( ﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ‬
‫ﺍﻵﺗﻲ‪:‬‬
‫• ﺃﻥ ﻳﺗﻡ ﺗﺻﻣﻳﻡ ﺍﻟﻌﻧﺎﺻﺭ ﺍﻟﺭﺋﻳﺳﻳﺔ ﺍﻷﺳﺎﺳﻳﺔ ﻓﻲ ﺍﻟﻣﻧﺷﺂﺕ ﻟﺗﺣﻣﻝ ﻗﻭﺓ‬
‫ﺧﺎﺭﺟﻳﺔ ﺇﺳﺗﺛﻧﺎﺋﻳﺔ ﻗﺩﺭﻫﺎ ‪ 34‬ﻛﻳﻠﻭ ﻧﻳﻭﺗﻥ‪ /‬ﻣﺗﺭ ‪2‬ﻣﺣﻣﻠﺔ ﺑﺎﻟﺗﻧﺎﻭﺏ‬
‫ﻋﻠﻰ ﺍﻟﺟﻬﺎﺕ ﻟﻬﺫﺍ ﺍﻟﻌﻧﺻﺭ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺍﻷﺣﻣﺎﻝ ﺍﻷﺧﺭﻯ ﺍﻟﺗﻲ‬
‫ﻳﺗﻌﺭﺽ ﻟﻬﺎ ﻫﺫﺍ ﺍﻟﻌﻧﺻﺭ‪.‬‬
‫• ﺃﻥ ﻳﺗﻡ ﺗﺻﻣﻳﻡ ﺟﻣﻳﻊ ﻋﻧﺎﺻﺭ ﺍﻟﻣﻧﺷﺂﺕ ﺑﺣﻳﺙ ﻳﺗﻡ ﺣﺻﺭ ﺃﻱ ﺇﻧﻬﻳﺎﺭ ﺣﺎﻝ‬
‫ﺣﺩﻭﺛﻪ ﻓﻲ ﺣﺩﻭﺩ‪ 70‬ﻣﺗﺭ ﻣﺭﺑﻊ ﺃﻭ ‪ 15%‬ﻣﻥ ﻣﺳﺎﺣﺔ ﺍﻟﻁﺎﺑﻖ ﺃﻳﻬﻣﺎ‬
‫ﺃﻗﻝ ﻭﺫﻟﻙ ﻟﻠﻁﺎﺑﻖ ﺍﻟﻣﻌﻧﻲ ﺍﻟﺫﻱ ﻳﻌﻠﻭﻩ ﻭﺍﻟﺫﻱ ﺃﺳﻔﻝ ﻣﻧﻪ ﻣﺑﺎﺷﺭﺓ‪.‬‬
‫• ﻭﺗﺣﻘﻳﻖ ﺫﻟﻙ ﻟﻠﻣﻧﺷﺂﺕ ﺑﺈﺭﺗﻔﺎﻉ ﺧﻣﺱ ﻁﻭﺍﺑﻖ ﺃﻭ ﺃﻛﺛﺭ ﻋﻧﺩﻣﺎ ﻳﺗﻡ‬
‫ﺇﻧﺷﺎﺅﻫﺎ ﺑﻌﺩ ﻣﺭﺍﻋﺎﺓ ﺗﻭﺻﻳﺎﺕ ﺍﻟﻛﻭﺩ ﺑﺷﺄﻥ ﺍﻟﺭﻭﺍﺑﻁ ﺩﺍﺧﻝ ﺍﻟﻣﺑﻧﻰ‬
‫ﻭﻋﻠﻰ ﻧﺗﺎﺋﺞ ﺳﻭء ﺇﺳﺗﺧﺩﺍﻡ ﺍﻟﻣﻧﺷﺎ ﺃﻭ ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺣﻭﺩﺍﺙ ﻭﺫﻟﻙ ﺑﻌﺩ‬
‫ﻣﺭﺍﻋﺎﺓ ﺍﻟﺗﺎﻟﻲ‪:‬‬
‫• ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ ‪ 8810-‬ﺍﻟﻣﺎﺩﺓ ‪ 2,2,2,2:‬ﺍﻟﺟﺯء ﺍﻻﻭﻝ‬
‫‪1997‬ﺍﻟﻣﺎﺩﺓ ‪6,2‬ﺍﻟﺟﺯء ﺍﻟﺛﺎﻧﻲ ‪: 1985‬ﻭﺫﻟﻙ ﻟﻠﻣﻧﺷﺂﺕ‬
‫ﺍﻟﺧﺭﺳﺎﻧﻳﺔ ﻭﺍﻟﺧﺭﺳﺎﻧﻳﺔ ﻣﺳﺑﻘﺔ ﺍﻹﺟﻬﺎﺩ‪.‬‬
‫• ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ – ‪ 5950‬ﺍﻟﻣﺎﺩﺓ ‪ 3,5,4,2‬ﺍﻟﺟﺯء‬
‫ﺍﻷﻭﻝ ‪:1985‬ﻟﻠﻣﻧﺷﺂﺕ ﺍﻟﻣﻌﺩﻧﻳﺔ‪.‬‬
‫• ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ ‪ 5628-‬ﺍﻟﻣﺎﺩﺓ ‪ 37 :‬ﺍﻟﺟﺯء ﺍﻷﻭﻝ ‪1985‬‬
‫ﻟﻣﻧﺷﺂﺕ ﺍﻟﻁﺎﺑﻭﻕ‪ .‬ﻭﺫﻟﻙ ﻟﻠﺗﻘﻠﻳﻝ ﻣﻥ ﻗﺎﺑﻠﻳﺔ ﺍﻟﻣﻧﺷﺄﺓ ﻟﻺﻧﻬﻳﺎﺭ‬
‫ﺍﻟﻣﺗﻭﺍﻟﻲ ﻭﻏﻳﺭ ﺍﻟﻣﺗﻛﺎﻓﺊ‪.‬‬

‫ﺍﻟﺗﺻﻣﻳﻡ ﺿﺩ ﺗﺄﺛﻳﺭ ﺍﻟﺯﻻﺯﻝ‬ ‫•‬


‫ﻳﺟﺏ ﺍﻷﺧﺫ ﻓﻲ ﺍﻹﻋﺗﺑﺎﺭ ﺗﺄﺛﻳﺭ ﺍﻟﺯﻻﺯﻝ ﻋﻧﺩ ﺗﺻﻣﻳﻡ ﺍﻟﻣﺑﺎﻧﻲ ﺍﻟﺗﻲ ﻳﺯﻳﺩ‬
‫ﺇﺭﺗﻔﺎﻋﻬﺎ ﻋﻥ ﻋﺷﺭﺓ ﻁﻭﺍﺑﻖ‪.‬‬

‫ﺍﻟﺗﺻﻣﻳﻡ ﺿﺩ ﺗﺄﺛﻳﺭ ﺍﻟﻘﻭﻯ ﺍﻷﻓﻘﻳﺔ‬ ‫•‬


‫ﻓﻲ ﺣﺎﻝ ﺗﺻﻣﻳﻡ ﺍﻟﻣﺑﺎﻧﻲ ﻟﻠﻘﻭﻯ ﺍﻻﻓﻘﻳﺔ ﻳﺗﻭﺟﺏ ﺗﺻﻣﻳﻡ ﺍﻟﻣﺑﻧﻰ ﻟﻠﻘﻭﺓ‬
‫ﺍﻷﻛﺑﺭ ﻣﻥ ﻗﻭﻯ ﺍﻟﺯﻻﺯﻝ ﻗﻭﻯ ﺍﻟﺭﻳﺎﺡ ﺃﻭ ﺍﻟﻘﻭﻯ ﺍﻷﻓﻘﻳﺔ ﺍﻟﻧﻅﺭﻳﺔ‬
‫ﺍﻟﻣﺭﻛﺯﻳﺔ ﺍﻟﻣﻌﺭﻓﺔ ﻓﻲ ﺍﻟﻣﺎﺩﺓ ﺭﻗﻡ )‪ (2-4-1-3‬ﻣﻥ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ‬
‫ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ – ‪ 8110‬ﺍﻟﺟﺯء ﺍﻷﻭﻝ ‪ -1997‬ﻭﻟﻛﻥ ﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ‬
‫ﺗﻔﺎﺻﻳﻝ ﺗﺳﻠﻳﺢ ﺍﻟﺣﺩﻳﺩ ﺗﺗﻼءﻡ ﻣﻊ ﻣﺗﻁﻠﺑﺎﺕ ﺍﻟﺗﺻﻣﻳﻡ ﻹﺣﺗﻣﺎﻝ‬
‫ﺍﻟﺯﻻﺯﻝ ‪.‬ﻭﻳﺟﺏ ﻣﺭﺍﻋﺎﺓ ﺍﻹﺷﺗﺭﺍﻁﺎﺕ ﺍﻟﻔﻧﻳﺔ ﻓﻲ ﺍﻟﻌﻧﺎﺻﺭ ﺍﻟﺗﺎﻟﻳﺔ‪:‬‬
‫• ﺍﻟﻁﺎﺑﻭﻕ‪:‬‬
‫ﺗﺷﻳﻳﺩ ﺟﺩﺭﺍﻥ ﻣﻥ ﺍﻟﻁﺎﺑﻭﻕ ﺍﻟﺧﺭﺳﺎﻧﻲ ﺍﻟﻌﺎﺩﻱ ﺑﺻﻭﺭﺓ ﻣﺗﺭﺍﺻﺔ ﻭﻣﺗﺭﺍﺑﻁﺔ‬
‫ﻭﺑﺎﺳﺗﺧﺩﺍﻡ ﻣﻭﻧﻪ ﺃﺳﻣﻧﺗﻳﺔ‪ ،‬ﻭﻳﺟﺏ ﺗﻁﺎﺑﻖ ﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻁﺎﺑﻭﻕ ﻣﻊ ﺍﻟﺷﺭﻭﻁ‬
‫ﺍﻟﻣﻧﺻﻭﺹ ﻋﻠﻳﻬﺎ ﻓﻲ ﺍﻟﺗﺷﺭﻳﻌﺎﺕ ﺍﻟﺻﺎﺩﺭﺓ ﻋﻥ ﺍﻟﺑﻠﺩﻳﺔ ‪ .‬ﻋﻠﻣﺎ ﺍﻧﻪ ﻻ ﻳﺟﻭﺯ‬
‫ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﻁﺎﺑﻭﻕ ﺍﻟﺧﻔﻳﻑ ﻓﻲ ﺇﻧﺷﺎء ﺍﻟﺟﺩﺭﺍﻥ ﺍﻟﺣﺎﻣﻠﺔ ﻭﻋﻧﺩ ﺍﺳﺗﺧﺩﺍﻡ ﻫﺫﺍ‬
‫ﺍﻟﻁﺎﺑﻭﻕ ﻓﻲ ﺍﻟﺟﺩﺭﺍﻥ ﺍﻟﺧﺎﺭﺟﻳﺔ ﻏﻳﺭ ﺍﻟﺣﺎﻣﻠﺔ ﻳﺟﺏ ﻣﻌﺎﻟﺟﺔ ﺍﻟﺳﻁﺢ ﺍﻟﺧﺎﺭﺟﻲ‬
‫ﺑﻁﺑﻘﺔ ﻣﻥ ﺍﻟﺑﻼﺳﺗﺭ ﺃﻭ ﻁﻼء ﺫﻱ ﺧﺻﺎﺋﺹ ﻣﻘﺎﻭﻣﺔ ﻟﻠﺭﻁﻭﺑﺔ‪.‬‬
‫ﻛﻣﺎ ﻳﺟﺏ ﺗﺻﻣﻳﻡ ﺟﺩﺭﺍﻥ ﺍﻟﻁﺎﺑﻭﻕ ﺣﺳﺏ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ ‪ 562‬ﺍﻟﺟﺯء‬
‫ﺍﻷﻭﻝ‪ – 1978/1985‬ﻭﺃﻥ ﺗﻛﻭﻥ ﻗﻭﺓ ﺗﺣﻣﻝ ﺍﻟﻁﺎﺑﻭﻕ ﺍﻟﻣﺳﺗﺧﺩﻡ ﻟﻠﺟﺩﺭﺍﻥ‬
‫ﺍﻟﺣﺎﻣﻠﺔ ﻣﺗﻧﺎﺳﺑﺔ ﻣﻊ ﺳﻣﻙ ﻫﺫﻩ ﺍﻟﺟﺩﺭﺍﻥ ﻭﻛﻣﺎ ﻳﻠﻲ‪:‬‬
‫• ﻋﻧﺩ ﺇﺳﺗﺧﺩﺍﻡ ﺍﻟﻁﺎﺑﻭﻕ ﺍﻟﻣﺻﻣﺕ ﻟﻠﺟﺩﺭﺍﻥ ﺍﻟﺣﺎﻣﻠﺔ ﻟﻠﻣﺑﺎﻧﻲ ﻳﺟﺏ ﺃﻥ ﻻ‬
‫ﺗﻘﻝ ﻗﻭﺓ ﺍﻟﺗﺣﻣﻝ ﻋﻥ)‪ 9‬ﻧﻳﻭﺗﻥ‪/‬ﻣﻠﻡ ‪(2‬ﻟﺟﻣﻳﻊ ﺳﻣﺎﻛﺎﺕ ﺍﻟﺟﺩﺭﺍﻥ‬
‫• ﻋﻧﺩ ﺇﺳﺗﺧﺩﺍﻡ ﺍﻟﻁﺎﺑﻭﻕ ﺍﻟﻣﻔﺭﻍ ﻟﻠﺟﺩﺭﺍﻥ ﺍﻟﺣﺎﻣﻠﺔ ﻟﻠﻣﺑﺎﻧﻲ) ﺑﺎﺭﺗﻔﺎﻉ ﻻﻳﺯﻳﺩ‬
‫ﻋﻥ ﻁﺎﺑﻘﻳﻥ ( ﻓﻳﺟﺏ ﺃﻥ ﻻ ﺗﻘﻝ ﻗﻭﺓ ﺍﻟﺗﺣﻣﻝ ﻋﻥ )‪6‬ﻧﻳﻭﺗﻥ‪/‬ﻣﻠﻡ ‪(2‬ﻭﺳﻣﻙ‬
‫ﺍﻟﺟﺩﺭﺍﻥ ﻻﻳﻘﻝ ﻋﻥ‪ 200‬ﻣﻠﻡ‪.‬‬
‫• ﻻ ﻳﺟﻭﺯ ﺑﻧﺎء ﺟﺩﺭﺍﻥ ﺣﺎﻣﻠﺔ ﺑﺳﻣﻙ ﺃﻗﻝ‪ 150‬ﻣﻠﻡ ﺃﻭ ﺃﻗﻝ ﺑﻁﺎﺑﻭﻕ ﻏﻳﺭ‬
‫ﻣﺻﻣﺕ‪.‬‬
‫• ﻻ ﻳﺟﻭﺯ ﺇﺳﺗﺧﺩﺍﻡ ﻁﺎﺑﻭﻕ ﺑﺳﻣﻙ ﺃﻗﻝ ﻣﻥ‪ 150‬ﻣﻠﻡ ﻟﻠﺟﺩﺭﺍﻥ ﺍﻟﺣﺎﻣﻠﺔ‬
‫ﺍﻟﻣﻔﺭﺩﺓ ﻭﻟﻛﻥ ﻳﻣﻛﻥ ﺇﺳﺗﺧﺩﺍﻣﻪ ﻟﻠﺟﺩﺭﺍﻥ ﺍﻟﻣﺯﺩﻭﺟﺔ ﻣﻊ ﺇﺳﺗﺧﺩﺍﻡ‬
‫ﺍﻟﺭﻭﺍﺑﻁ ﺑﻳﻧﻬﺎ‪.‬‬
‫• ﻗﻭﺓ ﺍﻟﺗﺣﻣﻝ ﺍﻟﻣﺫﻛﻭﺭﺓ ﺃﻋﻼﻩ ﻋﺑﺎﺭﺓ ﻋﻥ ﻣﺗﻭﺳﻁ ﻟﻘﻭﻯ ﺗﺣﻣﻝ ﺍﻟﺿﻐﻁ‬
‫ﻟﻌﺩﺩ ﻋﺷﺭﺓ ﻁﺎﺑﻭﻗﺎﺕ ﻳﺗﻡ ﺇﺧﺗﻳﺎﺭﻫﺎ ﻋﻠﻰ ﺣﺳﺏ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ‬
‫‪6073-‬ﺍﻟﺟﺯء ﺍﻟﺛﺎﻧﻲ‪.‬‬
‫• ﺍﻟﻣﻭﻧﺔ ﺍﻹﺳﻣﻧﻳﺗﺔ‪:‬‬
‫ﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﺍﻟﻣﻭﻧﺔ ﺍﻹﺳﻣﻧﺗﻳﺔ ﺍﻟﻣﺳﺗﺧﺩﻣﺔ ﻓﻲ ﺑﻧﺎء ﺍﻟﺟﺩﺭﺍﻥ‬
‫ﻣﻌﺎﺩﻟﺔ ﻓﻲ ﻗﻭﺗﻬﺎ ﻋﻠﻰ ﺍﻷﻗﻝ ﻟﻧﺳﺑﺔ ‪) 6:1:1‬ﺍﻹﺳﻣﻧﺕ ﺍﻟﺑﻭﺭﺗﻠﻧﺩﻱ‬
‫‪ ،‬ﺍﻟﺟﻳﺭ‪ ،‬ﺍﻟﺭﻣﻝ ﺍﻟﻧﺎﻋﻡ( ﺑﻧﺳﺏ ﺣﺟﻡ ﺍﻟﻣﻭﺍﺩ ﺍﻟﺟﺎﻓﺔ‪ .‬ﺃﻭ ﺣﺳﺏ‬
‫ﺍﻟﻣﺫﻛﻭﺭﺓ ﻓﻲ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ ‪ 5628-‬ﺍﻟﺟﺯء ﺍﻷﻭﻝ‬
‫‪1978/ 1985‬ﻟﻠﻣﻭﻧﺔ ﺍﻟﻣﻭﺻﻭﻓﺔ ﺑﺎﻟﺩﺭﺟﺔ ﺍﻟﺛﺎﻟﺛﺔ ‪ ،‬ﻣﻊ ﻣﺭﺍﻋﺎﺓ‬
‫ﺗﺟﺎﻧﺱ ﺍﻟﻣﻭﻧﺔ ﺍﻹﺳﻣﻧﺗﻳﺔ ﻣﻊ ﺍﻟﻁﺎﺑﻭﻕ ﻭﻣﻛﺎﻥ ﺍﻹﺳﺗﺧﺩﺍﻡ‪.‬‬
‫• ﺭﻭﺍﺑﻁ ﺍﻟﺟﺩﺭﺍﻥ‪:‬‬
‫ﻳﺳﺗﺧﺩﻡ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ ‪ 1978-1243‬ﻟﻠﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻣﻌﺩﻧﻳﺔ‬
‫ﺍﻟﻣﺳﺗﺧﺩﻣﺔ ﻓﻲ ﺍﻟﺟﺩﺭﺍﻥ ﺍﻟﻣﺯﺩﻭﺟﺔ ﻣﺎﻟﻡ ﺗﻛﻥ ﻫﺫﻩ ﺍﻟﺟﺩﺭﺍﻥ‬
‫ﻣﻌﺭﺿﺔ ﻟﻅﺭﻭﻑ ﺑﻳﺋﻳﺔ ﻗﺎﺳﻳﺔ ﻭﻓﻲ ﻫﺫﻩ ﺍﻟﺣﺎﻟﺔ ﻳﺳﺗﺧﺩﻡ ﺍﻟﻔﻭﻻﺫ‬
‫ﺍﻟﺫﻱ ﻻ ﻳﺻﺩﺃ ﻭﻛﻣﺎ ﻭﺭﺩ ﻓﻲ ﺍﻟﻛﻭﺩ ﺍﻟﺑﺭﻳﻁﺎﻧﻲ ﺭﻗﻡ )‪ (5628‬ﺍﻟﺟﺯء‬
‫ﺍﻟﺛﺎﻟﺙ‪.‬‬
‫ﺍﻟﺟﺩﺭﺍﻥ ﺍﻟﺩﺍﻋﻣﺔ‪:‬‬ ‫•‬
‫ﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﺍﻟﺟﺩﺭﺍﻥ ﺍﻟﺣﺎﻣﻠﺔ ﻣﺭﺑﻭﻁﺔ ﺑﺻﻭﺭﺓ ﺟﻳﺩﺓ ﻓﻲ‬
‫ﻁﺭﻓﻳﻬﺎ ﺑﺟﺩﺍﺭ ﺩﻋﻡ ﻋﺭﺿﻲ ﺃﻭ ﻋﺎﻣﻭﺩ ﺧﺭﺳﺎﻧﻲ ﻋﻠﻰ ﺃﻥ ﺗﻛﻭﻥ‬
‫ﻫﺫﻩ ﺍﻟﺩﻋﺎﻣﺎﺕ ﺑﺄﺑﻌﺎﺩ ﻛﺎﻓﻳﺔ ﻟﺗﺩﻋﻳﻡ ﺍﻟﺟﺩﺍﺭ ﺍﻟﺣﺎﻣﻝ ﻋﻠﻰ ﻛﺎﻣﻝ‬
‫ﺇﺭﺗﻔﺎﻋﻪ‪.‬‬
‫ﺍﻟﻘﻁﻊ ﺃﻭ ﻗﺹ ﻓﻲ ﺍﻟﺟﺩﺍﺭﻥ‪:‬‬ ‫•‬
‫ﻳﺟﺏ ﺃﻥ ﻻ ﻳﺯﻳﺩ ﻋﻣﻖ ﺍﻟﻘﻁﻊ ﺍﻟﻌﻣﻭﺩﻱ ﻓﻲ ﺍﻟﺟﺩﺍﺭ ﻋﻥ ﺛﻠﺙ ﺳﻣﻙ‬
‫ﺍﻟﺟﺩﺍﺭ ﻛﻣﺎ ﺃﻥ ﻋﻣﻖ ﺍﻟﻘﻁﻊ ﺍﻷﻓﻘﻲ ﻓﻲ ﺍﻟﺟﺩﺍﺭﻥ ﻳﺟﺏ ﺃﻥ ﻻ‬
‫ﻳﺯﻳﺩ ﻋﻥ ﺳﺩﺱ ﺳﻣﻙ ﺍﻟﺟﺩﺭﺍﻥ ﻣﻊ ﻣﺭﺍﻋﺎﺓ ﻋﺩﻡ ﺗﺄﺛﻳﺭ ﺍﻟﻘﻁﻊ‬
‫ﻋﻠﻰ ﺇﺗﺯﺍﻥ ﻫﺫﻩ ﺍﻟﺟﺩﺭﺍﻥ‪.‬‬
‫ﺇﺧﺗﺑﺎﺭﺍﺕ ﺍﻟﺗﺭﺑﺔ ﻭﺍﻷﺳﺎﺳﺎﺕ‬ ‫•‬
‫ﻳﺗﻡ ﺇﺟﺭﺍء ﺇﺧﺗﺑﺎﺭﺍﺕ ﻣﻭﻗﻌﻳﺔ ﻟﻠﺗﺭﺑﺔ ﻣﻥ ﻗﺑﻝ ﻣﺧﺗﺑﺭ ﻓﺣﺹ ﺗﺭﺑﺔ‬ ‫•‬

‫ﻣﺭﺧﺹ ﻓﻲ ﺇﻣﺎﺭﺓ ﺃﻡ ﺍﻟﻘﻳﻭﻳﻥ ﻣﻊ ﺿﺭﻭﺭﺓ ﺩﺭﺍﺳﺔ ﺍﻟﻧﻭﺍﺣﻲ ﺍﻟﻔﻧﻳﺔ ﺍﻟﺗﺎﻟﻳﺔ‬


‫‪:‬‬
‫• ﻧﻭﻋﻳﺔ ﻁﺑﻘﺎﺕ ﺍﻟﺗﺭﺑﺔ ﻭﺧﺻﺎﺋﺻﻬﺎ‪.‬‬
‫• ﺗﻭﺻﻳﺎﺕ ﻫﻧﺩﺳﻳﺔ ﺑﻘﻭﺓ ﺗﺣﻣﻝ ﺍﻟﺗﺭﺑﺔ ﻭﻣﻘﺩﺍﺭ ﺍﻟﻬﺑﻭﻁ ﺍﻟﻣﺗﻭﻗﻊ‪.‬‬
‫• ﻣﻧﺳﻭﺏ ﺍﻟﻣﻳﺎﻩ ﺍﻟﺟﻭﻓﻳﺔ ﻭﻧﻭﻋﻳﺔ ﻭﻣﺣﺗﻭﻳﺎﺕ ﺍﻟﻣﻳﺎﺓ ﺍﻟﺟﻭﻓﻳﺔ‪.‬‬

‫• ﺗﺄﺛﻳﺭ ﺍﻟﻣﺩ ﻭﺍﻟﺟﺯﺭ ﻋﻠﻰ ﺇﺗﺯﺍﻥ ﺍﻷﺳﺎﺳﺎﺕ‪.‬‬


‫• ﻣﺗﻁﻠﺑﺎﺕ ﺳﻧﺩ ﺟﻭﺍﻧﺏ ﺍﻟﺣﻔﺭ‪.‬‬
‫• ﺗﻭﺻﻳﺎﺕ ﺑﻧﻭﻋﻳﺔ ﺍﻷﺳﺎﺳﺎﺕ‪.‬‬
‫ﻳﺟﺏ ﺗﺣﺩﻳﺩ ﻣﻭﺍﻗﻊ ﺣﻔﺭ ﺍﻹﺧﺗﺑﺎﺭ ﻋﻠﻰ ﺧﺭﻳﻁﺔ ﺍﻟﻣﻭﻗﻊ ﻭﺗﺣﺩﻳﺩ‬ ‫•‬

‫ﺍﻹﺣﺩﺍﺛﻳﺎﺕ ﺣﺳﺏ ﻣﺭﺟﻊ ﺍﻟﺑﻠﺩﻳﺔ ﺍﻟﻣﺳﺎﺣﻲ‪.‬‬


‫ﺗﻭﺻﻳﺔ ﺑﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺧﺭﺳﺎﻧﺔ ﻭﺍﻷﺳﻣﻧﺕ ﺍﻟﻣﻧﺎﺳﺑﺔ ﻟﺗﺭﺑﺔ ﺍﻟﻣﻭﻗﻊ‬ ‫•‬

‫)ﺣﺳﺏ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﺭﻳﻁﺎﻧﻳﺔ ‪ 5328 -‬ﺍﻟﺟﺯء ﺍﻷﻭﻝ ‪ – 1997‬ﻭﻧﺷﺭ‬


‫ﺳﻳﺭﻳﺎ ﺍﻟﺧﺎﺻﺔ ﺭﻗﻡ ‪ 31‬ﻋﻠﻰ ﺃﻥ ﻻ ﺗﻘﻝ ﻗﻭﺓ ﺍﻟﻛﺳﺭ ﻟﻠﺧﺭﺳﺎﻧﺔ ﺍﻟﻣﺳﻠﺣﺔ‬
‫ﻋﻥ ‪ 30‬ﻧﻳﻭﺗﻥ ‪ /‬ﻣﻠﻡ‪.( 2‬‬
‫ﻳﺟﺏ ﺃﻥ ﺗﻛﻭﻥ ﺍﻷﺳﺎﺳﺎﺕ ﺿﻣﻥ ﺣﺩﻭﺩ ﺍﻷﺭﺽ ﻭﻳﺳﻣﺢ ﺑﺑﺭﻭﺯ ﺍﻟﻘﻭﺍﻋﺩ‬ ‫•‬

‫ﺧﺎﺭﺝ ﺣﺩﻭﺩ ﺍﻷﺭﺽ ﻓﻲ ﺣﺩﻭﺩ‪ 40‬ﺳﻡ ﻣﻥ ﻧﺎﺣﻳﺔ ﺍﻟﻁﺭﻳﻖ‪ ،‬ﻭﻳﺟﺏ ﺃﻻ ﻳﻘﻝ‬


‫ﻋﻣﻖ ﺍﻟﺗﺄﺳﻳﺱ ﻟﻠﻘﻭﺍﻋﺩ ﻋﻥ ﻋﻣﻖ ﺍﻟﻣﺣﺩﺩ ﻓﻲ ﺗﻘﺭﻳﺭ ﺍﻟﺗﺭﺑﺔ ‪ .‬ﻭﺫﻟﻙ‬
‫ﻟﺣﻣﺎﻳﺔ ﺍﻟﻘﺎﻋﺩﺓ ﻣﻥ ﺇﻧﺟﺭﺍﻑ ﺍﻟﺗﺭﺑﺔ ﻭﺗﻐﻳﺭﺍﺕ ﺍﻟﺭﻁﻭﺑﺔ ﺍﻟﻧﺎﺟﻣﺔ ﻋﻥ‬
‫ﺍﻟﻅﺭﻭﻑ ﺍﻟﻣﻧﺎﺧﻳﺔ ﻭﺍﻟﺣﺭﺍﺭﺓ‪.‬‬

‫ﻳﺟﺏ ﺗﻭﻓﻳﺭ ﻧﻅﺎﻡ ﻟﺗﺻﺭﻳﻑ ﺍﻟﻣﻳﺎﻩ ﺍﻟﺟﻭﻓﻳﺔ ﺇﺫﺍ ﻟﺯﻡ ﺍﻷﻣﺭ ﻟﻠﺣﻳﻠﻭﻟﺔ ﺩﻭﻥ‬ ‫•‬

‫ﺗﺳﺭﺏ ﺍﻟﺭﻁﻭﺑﺔ ﺇﻟﻰ ﺩﺍﺧﻝ ﺍﻟﻣﺑﻧﻰ‪.‬‬

‫ﻋﻧﺩ ﻋﻣﻝ ﺣﻔﺭﻳﺎﺕ ﻋﻣﻳﻘﺔ ﻟﻁﺎﺑﻖ ﺍﻟﺳﺭﺩﺍﺏ ﺃﻭﻏﻳﺭﻫﺎ ﻳﺟﺏ ﺗﻭﻓﻳﺭ ﻧﻅﺎﻡ‬ ‫•‬

‫ﺣﻣﺎﻳﺔ ﻟﺳﻧﺩ ﺟﻭﺍﻧﺏ ﺍﻟﺣﻔﺭ ﺩﺍﺧﻝ ﺣﺩﻭﺩ ﺍﻻﺭﺽ ‪ .‬ﻭﻗﺩ ﺗﺳﻣﺢ ﺑﺧﺭﻭﺝ‬
‫ﻧﻅﺎﻡ ﺳﻧﺩ ﺟﻭﺍﻧﺏ ﺍﻟﺣﻔﺭ ﻋﻥ ﺣﺩﻭﺩ ﺍﻷﺭﺽ ﻣﻥ ﺟﻬﺔ ﺍﻟﺷﺎﺭﻉ ﺃﻭ ﺍﻟﺳﻛﺔ‬
‫ﺑﻌﺩ ﺃﺧﺫ ﺍﻟﻣﻭﺍﻓﻘﺎﺕ ﺍﻟﺧﻁﻳﺔ ﻣﻥ ﺍﻟﺑﻠﺩﻳﺔ ‪ ،‬ﻭﻳﺟﺏ ﺃﻥ ﻳﺭﺍﻋﻲ ﻓﻲ ﺗﺻﻣﻳﻣﻬﺎ‬
‫ﺃﻥ ﻻ ﺗﺅﺛﺭ ﻋﻠﻰ ﺍﻟﻣﺑﺎﻧﻲ ﻭﺍﻟﺧﺩﻣﺎﺕ ﺍﻟﻣﺟﺎﻭﺭﺓ‪.‬‬
‫ﻻ ﻳﺟﻭﺯ ﺇﺳﺗﺧﺩﺍﻡ ﻁﺭﻳﻘﺔ)ﺍﻟﺩﻕ(ﻓﻲ ﺗﺛﺑﺕ ﺍﻷﻭﺗﺎﺩ ﺃﻭ ﺇﺳﺗﺧﺩﺍﻡ ﺍﻹﻫﺗﺯﺍﺯ‬ ‫•‬

‫ﻓﻲ ﺗﻘﻭﻳﺔ ﺍﻟﺗﺭﺑﺔ ‪ .‬ﻭﻓﻲ ﺣﺎﻝ ﺍﻟﻠﺟﻭء ﻟﻬﺫﻩ ﺍﻟﻁﺭﻳﻘﺔ ﻓﻲ ﺍﻷﺳﺎﺳﺎﺕ‬


‫ﻳﺗﻭﺟﺏ ﺍﻟﺣﺻﻭﻝ ﻋﻠﻰ ﺍﻟﻣﻭﺍﻓﻘﺔ ﺍﻟﻣﺳﺑﻘﺔ ﻋﻠﻰ ﺫﻟﻙ ﻣﻥ ﺍﻟﺑﻠﺩﻳﺔ‪.‬‬

‫ﺍﻟﻣﺻﺎﺩﺭ ﻭﺍﻟﻣﺭﺍﺟﻊ‪:‬‬
‫ﻻﺋﺣﺔ ﺷﺭﻭﻁ ﻭﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﻧﺎء ﺑﺑﻠﺩﻳﺔ ﺩﺑﻲ‪.‬‬ ‫•‬

‫ﻻﺋﺣﺔ ﺷﺭﻭﻁ ﻭﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﺑﻧﺎء ﺑﺑﻠﺩﻳﺔ ﺍﻟﺷﺎﺭﻗﺔ‪.‬‬ ‫•‬

‫ﺍﻷﻣﺭ ﺍﻟﻣﺣﻠﻲ ﻓﻲ ﺷﺄﻥ ﺗﻧﻅﻳﻡ ﺍﻟﻣﺑﺎﻧﻲ ﺑﻣﺳﻘﻁ_ ﺳﻠﻁﻧﺔ‬ ‫•‬

‫ﻋﻣﺎﻥ‪.‬‬
‫ﺍﻷﻣﺭ ﺍﻟﻣﺣﻠﻲ ﻟﺗﻧﻅﻳﻡ ﺍﻟﺑﻧﺎء ﺑﻣﺣﺎﻓﻅﺔ ﻅﻔﺎﺭ_ ﺳﻠﻁﻧﺔ‬ ‫•‬

‫ﻋﻣﺎﻥ‪.‬‬
‫ﻗﺎﻧﻭﻥ ﺍﻟﺑﻧﺎء ﺭﻗﻡ‪1/85 .‬‬ ‫•‬

You might also like