10KW WD Series Inverter Split Phase Output-Without Solar Controller
10KW WD Series Inverter Split Phase Output-Without Solar Controller
Feature:
◆ Pure sine wave output;
◆ Added fault code query function,facilitate user to monitor the operation state in real time;
Product Parameters
Specification
10348/96/192
Model SWD
(103)
Size(L*W*Hmm) 540x350x695
N.W.(kg) 70
G.W.(kg) 81
185VAC~255VAC(220VAC) /
AC Input Voltage Range
195VAC~265VAC(230VAC) / 205VAC~275VAC( 240VAC)
Input
AC Input Frequency Range 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz)
Max AC charging current 0A~40A(Depending on the model,The maximum charging power is 1/4 of the rated power)
Output Voltage(Battery Mode) Split- Phase 110v/220v 50Hz/60Hz Outputs: L1-N/L2-N:110AC / L1-L2: 220VAC
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss
≤10W
(Energy saving Mode)
Battery Type VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
(selectable Charging and discharging parameters of different types of batteries can be customized according to user requirements
) Customize battery
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Battery undervoltage alarm Factory default: 11V(Single battery voltage)
Battery undervoltage protection Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm Factory default: 15V(Single battery voltage)
Battery overvoltage protection Factory default: 17V(Single battery voltage)
Protection
Battery overvoltage recovery voltage Factory default: 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Alarm B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Display LCD