PROPOSED ELEVATED WATER

TANK @ 3000 GALLONS


( FIRE TANK ) DUPLEX TYPE
DOWN BLADDER TANK CONSTANT PRESSURE
TANK CAP.=220 GALS. BOOSTER PUMP

32Ø CWS FROM


MAIN WATER
GV GV 75Ø FIRE WATER SUPPLY
CV CV
SUPPLY VERIFY FC FC
HEADER
PLUMBING 32Ø SUCTION LINE
LAYOUT
ELEV. = ( VERIFY ) 0.00M
ROOF SLAB OF
STAIR ROOF MANIFOLD SIAMESE TWIN
2-WAY X 65mmØ X 100mmØ INLET

ELEV. = ( VERIFY ) 0.00M


ROOF DECK
100Ø FIRE WATER SUPPLY
32Ø TANK DRAIN FP SS FS TO SPRINKLER
VERIFY PLUMBING LAYOUT 1A, 1B SYSTEM
FOR EXACT TAPPING POINT FLOOR CONTROL VALVE

40Ø FHL
SEE INSTALLATION DETAIL

100mmØ FIRE WATER SPRINKLER


BLADDER TANK
TANK CAP.=220 GALS.
50mmØ DRAIN PIPE RISER FHC-1
32Ø FLOAT VALVE
65mmØ FIRE HOSE VALVE 65mmØ FIRE HOSE VALVE
32Ø CWS FROM MAIN WATER WITH CAP & CHAIN
75Ø FIRE WATER SUPPLY SUPPLY, VERIFY PLUMBING LAYOUT
FIRE
ESCAPE
WITH CAP & CHAIN
HEADER FOR EXACT LOCATION ELEV. = ( VERIFY ) 0.00M
THIRD FLOOR
3000 GALS OF SS FS TO SPRINKLER
FIRE WATER TANK
S-TANK OR APPROVED EQUAL SYSTEM 100Ø DRY STAND PIPE RISER
32Ø SUCTION LINE FLOOR CONTROL VALVE

40Ø FHL
SEE INSTALLATION DETAIL
32Ø TANK DRAIN
TAP TO NEAREST DRAIN 100Ø WET FIRE DEPARTMENT CONNECTION
VERIFY PLUMBING LAYOUT RUNNING UNDERGROUND
FOR EXACT TAPPING POINT
100mmØ FIRE WATER SPRINKLER
100Ø DRY FIRE DEPARTMENT CONNECTION FHC-1
RUNNING UNDERGROUND 50mmØ DRAIN PIPE RISER
65mmØ FIRE HOSE VALVE 65mmØ FIRE HOSE VALVE
WITH CAP & CHAIN WITH CAP & CHAIN
ELEV. = ( VERIFY ) 0.00M
SECOND FLOOR
SS FS
TO SPRINKLER
FLOOR CONTROL VALVE SYSTEM

40Ø FHL
FIRE DEPT. CONN. (DRY) SEE INSTALLATION DETAIL
2-WAY X 65mmØ X 100mmØ INLET 100Ø DRY STAND PIPE RISER

FIRE DEPT. CONN. (WET) 100mmØ FIRE WATER SPRINKLER


2-WAY X 65mmØ X 100mmØ INLET FHC-1
50mmØ DRAIN PIPE RISER
65mmØ FIRE HOSE VALVE 65mmØ FIRE HOSE VALVE
WITH CAP & CHAIN WITH CAP & CHAIN

ELEV. = 0.00M
GROUND FLOOR CV
50mmØ DRAIN PIPE RISER
TAP TO NEAREST DRAIN
VERIFY PLUMBING LAYOUT
FOR EXACT TAPPING POINT
FIRE SPRINKLER &
WET & DRY STANDPIPE SCHEMATIC RISER DIAGRAM
FP 04 SCALE NTS

ROOFDECK
FIRE PROTECTION LAYOUT
Scale: 1:100MTS

CADD BY OWNER: DESCRIPTION DATE DRAWN APPROVED


PROJECT TITLE SHEET CONTENTS SHEET NO.
DATE
JAY CRISTOPHER P. DELA CRUZ
PROPOSED THREE (3)STOREY COMMERCIAL AS SHOWN

REVISION
..\..\..\Downloads\330613826_711951403604585_1821972323937313158_n.jpg PROFESSIONAL MECHANICAL ENGINEER DESIGNED BY :

PRC NO:0004815
NO: PTR: 1256083 DATE :
BUILDING WITH ROOFDECK ( 18 UNITS) MR. ADEL BALOGO FP-03
DATE: 01/03/2023 TIN: 178-981-634 CHECKED BY :
FILE NO.
APPROVED BY : LOCATION: LOT 31 & 32, BLK.10, SAUDI STREET, BETTER LIVING SUBD., BRGY. DON BOSCO, PARANAQUE CITY
PLACE: BOCAUE DATE