CONTENTS

Message iii
Preface v
Foreword vii
Vol. I
Chapter 1 : Introduction
1.1 Indian transmission system 1
1.2 Some of the significant achievements / milestones in Indian Power Transmission 3
system
Chapter 2 : General Requirement
2.1 Introduction 6
2.2 System Requirement and Basic Concepts 6
2.3 Planning of Substation 9
2.4 Site Selection 12
2.5 Design 15
2.6 Common Rated Characteristics of Switchgear and Control Gear 36
2.7 Voltage Limits Under Steady State, Temporary Over Voltage (TOV) and 37
Switching Over Voltage (Swov)
2.8 Reliability, Resilience And Availability 38
2.9 Studies For Substation 39
Annexure Short Circuit forces and Spacer span (for bundle conductors) 41
2.A
Annexure Typical Calculation for Short Circuit forces as per IEC 865 (1993) for flexible 43
2.B conductor and Rigid conductor
Chapter 3 : Type of Substations
3.1 Electrical Substation 56
3.2 Air Insulated Substations (Outdoor / Indoor) 57
3.3 Gas Insulated Substations (GIS) 57
3.4 Hybrid Substation 59
3.5 Digital substation 59
3.6 Mobile substation 60
3.7 Underground substation 60
3.8 Traction substation 61
3.9 Vertical EHV Sub-station 61
3.10 Substations Associated with Generation from Renewable Energy Sources 66
Chapter 4 : Bus-bar / Switching Schemes
4.1 Types of bus bar schemes 67
4.2 Selection of bus-bar schemes 67
4.3 Single Bus-Bar Scheme [Fig. 6(A), 6(B), & 6(C)] 68
4.4 Main and transfer bus arrangement [Fig. 6 (D)] 72
4.5 Double bus-bar scheme [Fig. 6(E) & 6(F)] 72
4.6 Double main and transfer bus bar scheme [Fig. 6 (G)] 76
4.7 Mesh bus bar scheme [Fig.6 (H)] 76
4.8 One and half Breaker scheme [Fig.6 (I) & 6(J)] 79
4.9 Double bus and double breaker scheme [Fig. 6 (K)] 79
4.10 Location of Current transformers 83

xi
Chapter 5 : Substation Equipment/ Component
5.1 Introduction 84
5.2 Circuit-breakers 84
5.3 Disconnecting Circuit-breaker (DCB) 87
5.4 Generator Circuit Breaker (GCB) 87
5.5 Disconnectors (isolators) and Earth switches 89
5.6 Surge Arresters 91
5.7 Line Surge Arresters 94
5.8 Instrument Transformers (ITs) 96
5.9 Sulfur hexaflouride (SF6) and g3 (green gas for gird) Gas 98
5.10 Power Transformers 99
5.11 Compensating Equipment 100
5.12 Controlled Shunt Reactor (CSR) 105
5.13 Line traps 105
5.14 Communication system 105
5.15 Phasor Measurement Units (PMU) 106
5.16 Busbars and Connectors 107
5.17 Insulators 107
5.18 Post Insulators 108
5.19 High Voltage Cables 108
5.20 Power and Control Cables 108
5.21 Substation structure 108
5.22 Condition Monitoring of Equipment 109
Annexure A Typical Specification for major substation equipment (CB, Disconnector, IT, 112
SA) / materials and General Technical Requirement (GTR)
Annexure AA Typical Manufacturers’ Quality Plan (MQP) for major substation equipment 207
(CB, Disconnector, IT, SA)
Chapter 6 : Substation Auxiliary Facilities
6.0 Introduction 299
6.1 Earthing System 299
6.2 Direct Stroke Lightning Protection (Dslp) System 303
6.3 AC & DC Supply System 305
6.4 Illumination / Lighting System 308
6.5 Fire Fighting System 312
6.6 Air Conditioning System 322
6.7 Ventilation System 323
6.8 Cabling 324
6.9 Oil Storage, Handling & Filteration System 326
6.10 SfF6 Filling, Evacuation, Filtering, Drying & Recycling Plant And Sf6 Leak 326
Detector
6.11 Compressed Air System 328
6.12 Crane Facilities 329
6.13 Public Announcment (PA) System 329
Chapter 7 : Insulation Co-Ordination and Safety Clearance
7.1 Some Definitions 331
7.2 Over voltage, Insulation Co-ordination and Insulation levels 331

xii
7.3 Electrical Clearance 334
7.4 The insulation level for the switchgear (Circuit Breaker, Isolator, Instrument 338
transformers), transformer & reactor winding and bushings could be as Shown
in Table 7.5.
7.5 Altitude Correction as per IEEE Standard and IEC Standard 339

Vol. II
Chapter 8 : Physical Layouts
8.1 Introduction 341
8.2 Some of the major considerations in development / planning of layout of 341
substation / switchyard
Chapter 9 : Erection & Commissioning
9.1 Introduction 348
9.2 Bay Equipment 348
9.3 Equipment Erection 348
9.4 Bay Marshalling Kiosk 349
9.5 Bay and Phase Identification 349
9.6 Bus Bars 349
9.6 Earthing System 350
9.7 Lightning Protection 353
9.8 Installation of Cables 354
9.9 Civil Works 355
9.10 Building Design Considerations 367
9.11 Design of Foundations for Equipment & Buildings & Other Switch Yard 367
Structures
9.12 Design of Water Tanks, Channels, Sumps, Trenches and other Under-Ground 367
Structures
Annexure Guidelines for classification of Foundations in different Soils 368
9.A
Annexure Bond Stresses 369
9.B
Annexure I Pre-Commissioning Formats 370
Pre-commissioning Formats for Circuit Breaker (CB) 370
Pre-commissioning Formats for Isolator & Grounding Switch 394
Pre-commissioning Formats for Current Transformer (CT) 403
Pre-commissioning Formats for Capacitive Voltage Transformer (CVT) 422
Pre-commissioning Formats for Surge Arrester 430
Pre-commissioning Formats for Wave Trap 435
Pre-commissioning Formats for Transformer 439
Pre-commissioning Formats for Reactor 491
Pre-commissioning Check list for Control and Protection including PLCC
Line Protection 524
Line Reactor Protection 534
Bus Reactor Protection 540
Auto Transformer Protection 545
Control Panel 550
Bus Bar Protection 556

xiii
Others (Disturbance Recorder, Sequence Event Recorder, OLTC / RTCC for 557
Transformer etc.)
Check for PLCC 563
Substation Automation System (SAS) 568
Annexure II Pre-Commissioning Formats for Gas Insulated Substations 577
Pre-Commissioning Test on EOT Crane 578
Pre-Commissioning Test Shock Recorders 578
Pre-Commissioning Checks on SF6 Gas 579
Pre-Commissioning Checks on Circuit Breakers 581
Pre-Commissioning Checks on Current Transformers 590
Pre-Commissioning Checks on Potential Transformers 599
Pre-Commissioning Formats for Isolator and Grounding Switch 603
Pre-Commissioning Checks on GIS 607
Annexure III Standardised Field Quality Plan (FQP) for AIS 636
Erection work Power Transformers & Reactors 643
Check List (CF-1) Receipt and Storage Checks 653
Check List (CF-2) Erection Checks 654
Check List (CF-3) Evacuation and Oil filling Checks 656
Annexure IV Field Quality Plan (FQP) for GIS 659

Chapter 10 : New Technologies


10.1 Introduction 670
10.2 Technology Options for Transmission System 671
(a) Gas Insulated Substation (GIS) and Hybrid sub-station 671
(b) Non-Conventional Instrument Transformers (NCIT) and Merging unit 671
(MU)
(c) Digital Substation 673
(d) Controlled Switching Device (CSD) 675
(e) Fault Current Limiter (FCL) suitable for Extra High Voltage (EHV) System 675
(f) OPGW based reliable Communication and Protection system 679
(g) Wide Area Measurement System (WAMS) 680
(h) Use of High Temperature (HT) / High Temperature Low Sag (HTLS) 680
conductors
(i) EHV XLPE Cable and Gas Insulated Transmission Line (GIL) 681
(j) Resin Impregnated Paper (RIP) & Resin Impregnated Synthetics (RIS) 683
bushing and Vacuum type On Load Tap Changer (OLTC)
(k) Ester Oil 685
(l) Use of Polymer based Insulation and RTV coating 685
(m) Phase Shifting Transformer (PST) 687
(n) High Voltage Direct Current (HVDC): Conventional Line-Commuted 687
Current Source Converters (CSCs) based HVDC and self-commutated
Voltage Source Converters (VSCs) based HVDC system(o) FACTS
Installations in sub-stations & FACTS Devices (FSC, TCSC, MSC, MSR,
SVC, STATCOM)
(o) FACTS Installations in sub-stations & FACTS Devices (FSC, TCSC, MSC, 696
MSR, SVC, STATCOM)
(p) Energy Storage System 713
(q) Smart Grid 715

xiv
Chapter 11 : Refurbishment, Upgradation and Uprating of Existing Substations
11.1 Upgradation and uprating 717
11.2 Some of the technical considerations for upgradation and uprating 718
11.3 The details of upgradation / uprating taken up in some existing substations in 720
India
11.5 Refurbishment 735
Chapter 12 : Life Cycle Management
12.1 The Life Cycle Management (LCM) of a substation or the equipment within the 736
substation
Chapter 13 : Substation Safety
13.1 Introduction 742
13.2 Safety Regulations & Standards 743
13.3 Safety Risks during Erection, operation, maintenance and dismantling 744
13.4 Engineering, Education and Enforcement of Safety 747
13.5 Electrical Hazards and safety requirement in Substations 748
13.6 Operational controls 751
13.7 Some of the Electrical Safety aspects 752
13.8 Physical Barriers and Warnings / Signages 756

Chapter 14 : Reference Standards and Documents 760

Vol. III (In CD)


Table 8.3 : List of Drawings

Sl. No. Description Drawing No.


1 Typical 765/132 kV Air Insulated Generating Switchyard:
Single Line Diagram (SLD) with Breaker & half Scheme at 765 kV level Dwg. No. 8.1(a)
and Double Main bus Scheme at 132 kV level
Electrical Layout Plan for 765/132 kV Switchyard Dwg. No. 8.1(b)
Electrical Sectional Elevation for 765 kV yard Dwg. No. 8.1(c)
Electrical Sectional Elevation for 132 kV yard Dwg. No. 8.1(d)

2 Typical 765/400 kV Air Insulated Substation:


Single Line Diagram (SLD) with Breaker & half Scheme at 765kV & 400 Dwg. No. 8.2(a)
kV level
Electrical Layout Plan for 765/400 kV Substation Dwg. No. 8.2(b)
Electrical Layout Plan for 765 kV yard Dwg. No. 8.2(c)
Electrical Layout Plan for 400 kV yard Dwg. No. 8.2(d)
Electrical Sectional Elevation for 765 kV yard Dwg. No. 8.2(e)
Electrical Sectional Elevation for 400 kV yard Dwg. No. 8.2(f)
Structural Layout Plan for 765/400 kV yard Dwg. No. 8.2(g)
Sectional View of Structural Layout for 765 kV yard Dwg. No. 8.2(h)
Sectional View of Structural Layout for 400 kV yard Dwg. No. 8.2(i)
DSLP Layout Plan for 765/400 kV Substation Dwg. No. 8.2(j)

3 Typical 765/400 kV Air Insulated Substation:


Single Line Diagram (SLD) with Breaker & half Scheme at 765 kV level Dwg. No. 8.3(a)

xv
Single Line Diagram (SLD) with Breaker & half Scheme at 400 kV level Dwg. No. 8.3(b)
Electrical Layout Plan for 765 kV System Dwg. No. 8.3(c)
Electrical Layout Plan for 400 kV System Dwg. No. 8.3(d)
Electrical Sectional Elevation for 765 kV System (Option-1) Dwg. No. 8.3(e)
Electrical Sectional Elevation for 765 kV System Dwg. No. 8.3(f)
Electrical Sectional Elevation for 400 kV System Dwg. No. 8.3(g)

4 Typical 765/400/220 kV Air Insulated Substation (AIS):


Single Line Diagram (SLD) with Breaker & Half Scheme at 765 kV & 400 Dwg. No. 8.4(a)
kV level
SLD for switching of single phase 765/400 kVkV ICT, 765 kV Bus Reactor Dwg. No. 8.4(b)
and 765 kV Line reactor including Spare unit
Layout plan of 765/400 kV Single Phase ICTs Dwg. No. 8.4(c)
Sectional view for 765/400kV Single Phase ICT area (Section at A-A, B-B, Dwg. No. 8.4(d)
C-C- J-J etc.)
SLD for switching of single phase 765kV Bus reactor and 765kV Line Dwg. No. 8.4(e)
reactor (including spare unit)
Layout plan and Sectional view of 765 kV Single Phase Line reactor area Dwg. No. 8.4(f)
Layout plan and Sectional view of 765 kV Single Phase Bus reactor area Dwg. No. 8.4(g)
Layout Plan of Cable Trench for 765 kV & 400 kV system Dwg. No. 8.4(h)
Pipe Trenches for 765 kV & 400 kV equipment including isolators, Surge Dwg. No. 8.4(i)
Arresters & CVT etc.
Layout Plan of Ground Floor for Control Room Building Dwg. No. 8.4(j)
Layout Plan of First Floor for Control Room Building Dwg. No. 8.4(k)
Elevation of Control Room Building (Front & Rear) Dwg. No. 8.4(l)
Elevation of Control Room Building (Left & Right side) Dwg. No. 8.4(m)
Sectional View of Control Room Building (Section at A-A & B-B) Dwg. No. 8.4(n)

5 Typical SLD for switching of 765 kV Spare line reactor in a bank Dwg. No. 8.5

6 Typical SLD for switching of 765/400/33 kV Spare ICT in a bank Dwg. No. 8.6

7 765/400 kV Bikaner (New) Air Insulated Substation:


Single Line Diagram (SLD) with Breaker & half Scheme at 765kV & 400 Dwg. No. 8.7(a)
kV levels showing single phase connection of 765/400kV ICT and 765 kV
line & Bus Reactors
Electrical Layout Plan for 765 kV & 400 kV System Dwg. No. 8.7(b)
Electrical Sectional Elevation for 765 kV System Dwg. No. 8.7(c)
Electrical Sectional Elevation for 400 kV System Dwg. No. 8.7(d)
Layout Plan for foundations of 765 kV & 400 kV system Dwg. No. 8.7(e)

8 765/400 kV Koteswar Pooling GIS Substation (in different Terraces with


Pre-Engineered Building):
Single Line Diagram (SLD) with Breaker & half Scheme at 765 kV level Dwg. No. 8.8(a)
and Double Main Bus Scheme at 400 kV level
Electrical Layout Plan for complete Substation Dwg. No. 8.8(b)
Electrical Sectional Elevation for 765 kV & 400 kV System Dwg. No. 8.8(c)
765 kV GIS Hall and local Control Room Dwg. No. 8.8(d)
400 kV GIS Hall and local Control Room Dwg. No. 8.8(e)

xvi
9 Typical GIS Layout Plans (765 kV & 400 kV)
Typical Electrical Layout Plan -1 (765 kV GIS) Dwg. No. 8.9(a)
Typical Electrical Layout Plan -2 (765 kV GIS) Dwg. No. 8.9(b)
Typical Electrical Layout Plan -3 (400 kV GIS) Dwg. No. 8.9(c)
Typical Electrical Layout Plan -4 (400 kV GIS) Dwg. No. 8.9(d)

10 765 kV Aligarh GIS Substation:


Overall Electrical Layout Plan Dwg.No. 8.10(a)
Electrical Layout Plan for 765kV GIS inside the Building Dwg.No. 8.10(b)
Electrical Sectional Elevation for 765kV GIS inside the Building Dwg. No. 8.10(c)

11 Typical 400/220/132 kV Air Insulated Substation:


Electrical Layout Plan and Single Line Diagram (SLD) with Double Main Dwg.No. 8.11(a)
and Transfer Bus Scheme at 400 kV, 220 kV & 132kV levels
Electrical Sectional Elevation for 400 kV, 220 kV & 132 kV system Dwg.No. 8.11(b)

12 Control Room Building Plan of a Typical 440/220 kV substation:


Ground Floor Plan Dwg.No. 8.12(a)
Sectional Views (at AA & ABCD) Dwg.No. 8.12(b)

13 Typical 400 kV Indoor GIS substation for interconnection with Outdoor Air
Insulated System:
Electrical Layout Plan for AIS to GIS interconnection Dwg.No. 8.13(a)
Electrical Sectional elevation for AIS to GIS interconnection Dwg.No. 8.13(b)
400kV Gas Single Line Diagram Dwg.No. 8.13(c)
Outdoor Cable Trench layout Dwg.No. 8.13(d)
Indoor Cable Trench layout and Sectional View (indoor & outdoor trenches Dwg.No. 8.13(e)
etc.)
400 kV Panel Arrangement Dwg.No. 8.13(f)
Earthmat layout Dwg.No. 8.13(g)
DSLP Protection Dwg.No. 8.13(h)

14 Typical 400/220 kV GIS Substation: Electrical Layout Plan, Sectional Dwg.No. 8.14
Elevation and Single Line Diagram (SLD) with Double Main Bus Scheme
at 400 kV & 220 kV levels

15 400/220/66 kV Harsh Vihar GIS Substation:


Single Line Diagram (SLD) with Double Main Bus Scheme at 400 kV, 220 Dwg.No. 8.15(a)
kV & 66 kV levels
General Arrangement / Overall Layout plan of 400/220/66 kV Substation Dwg.No. 8.15(b)
Electrical Layout Plan & Sectional Elevation for 400 kV System Dwg.No. 8.15(c)
Electrical Layout Plan & Sectional Elevation for 220 kV & 66 kV System Dwg.No. 8.15(d)
Single Line Diagram for AC distribution Board Dwg.No. 8.15(e)

16 400/220 kV Banaskantha (Radhanesda) New GIS Pooling Station: Control Dwg.No. 8.16
Room Building Equipment Layout Plan

xvii
17 Typical 220/132kV Outdoor Air Insulated Substation (with Flexible Bus Dwg.No. 8.17
arrangement at 220kV level): Electrical Layout Plan, Sectional Elevation
and Single Line Diagram (SLD) with Double Main Bus Scheme at 220kV
levels

18 Typical 220/132 kV Outdoor Air Insulated Substation (with Rigid / Pipe Bus Dwg.No. 8.18
arrangement at 220 kV level): Electrical Layout Plan, Sectional Elevation
and Single Line Diagram (SLD) with Double Main Bus Scheme at 220 kV
level

19 Typical 220/33 kV Substation (Augmentation)


Single Line Diagram (SLD) with Double Main Bus Scheme at 220kV level Dwg.No. 8.19(a)
Electrical Layout Plan for 220kV & 33kV System Dwg.No. 8.19(b)
Electrical Sectional Elevation for 220kV & 33kV System Dwg.No. 8.19(c)

20 220/66 kV Kargil GIS Substation with 220/66/11 kV, 4x16.67 MVA Single
phase Transformers (at High Altitude: 2682 m above MSL with Pre-
Engineered Building):
Single Line Diagram (SLD) with Double Main Bus Scheme at 220 kV level Dwg.No. 8.20(a)
with CT & CVT details
Electrical Layout Plan for 220kV & 66 kV System Dwg.No. 8.20(b)
Electrical Sectional Elevation for 220 kV & 66 kV System Dwg.No. 8.20(c)

21 220/66kV Drass GIS Substation with 220/66/11kV, 4x16.67MVA Single


phase Transformers (at High Altitude: 3066m above MSL with Pre-
Engineered Building):
Single Line Diagram (SLD) with Double Main Bus Scheme at 220kV level Dwg.No. 8.21(a)
with CT & CVT details
Electrical Layout Plan for 220kV & 66kV System Dwg.No. 8.21(b)
Electrical Sectional Elevation for 220kV & 66kV System Dwg.No. 8.21(c)

22 230/110kV Thiruverkadu Hybrid GIS Substation:


Single Line Diagram (SLD) with Double Main bus Scheme at 230kV & Dwg.No. 8.22(a)
110kV levels
Electrical Layout Plan for 230 kV & 110kV system Dwg.No. 8.22(b)
Electrical Sectional Elevation for 230 kV & 110kV system Dwg.No. 8.22(c)

23 220/66kV Chandigarh (New) GIS Substation:


Single Line Diagram (SLD) with Double Main bus Scheme at 220kV level Dwg.No. 8.23(a)
and Single bus Scheme at 66kV level
General arrangement / overall Electrical Layout Plan for 220/66kV Dwg.No. 8.23(b)
substation

24 Protection Key Diagram for 400/220kV Kishanganj GIS substation:


For 400kV Line bay with reactor and 400/220/33kV Inter Connecting Dwg.No. 8.24(a)
Transformer (ICT) bay (400kV) in same Diameter
For 400kV Bus reactor bay and 400/220/33kV Inter Connecting Transformer Dwg.No. 8.24(b)
(ICT) bay (400kV) in same Diameter
For 220kV Side of ICT bay Dwg.No. 8.24(c)

xviii
For 220kV Line bay Dwg.No. 8.24(d)
For 220kV Bus Coupler Bay Dwg.No. 8.24(e)

25 Protection & metering SLD for 220/66/11kV Brindavan GIS Substation Dwg.No. 8.25

26 Typical Control Room Building for 400/220kV AIS with Conventional


Control & relay panels
Layout Plan of Ground Floor Dwg.No. 8.26(a)
Layout Plan of First Floor Dwg.No. 8.26(b)

27 Typical 400 kV layout with Double Main & Transfer (DMT) Bus Scheme
SLD with DMT scheme and Electrical Layout Plan Dwg.No. 8.27(a)
Electrical Sectional Elevation Dwg.No. 8.27(b)

28 Typical 400 kV layout with Breaker & Half Scheme (D-Type Arrangement)
SLD with Breaker & Half Scheme Dwg.No. 8.28(a)
Electrical Layout Plan (for D-Type arrangement) Dwg.No. 8.28(b)
Electrical Sectional Elevation Dwg.No. 8.28(c)

29 Typical 400 kV layout with Breaker & Half Scheme (I-Type Arrangement)
SLD with Breaker & Half Scheme Dwg.No. 8.29(a)
Electrical Layout Plan (for I-Type arrangement) Dwg.No. 8.29(b)
Electrical Sectional Elevation (A-A, B-B, C-C) Dwg.No. 8.29(c)
Electrical Sectional Elevation (D-D, E-E, F-F, G-G, H-H) Dwg.No. 8.29(d)
Electrical Layout Plan for single phase 400/220kV ICT area with Auxiliary Dwg.No. 8.29(e)
Bus arrangement
Electrical Sectional Elevation for single phase ICT area Dwg.No. 8.29(f)

30 Typical 400kV layout with Breaker & Half Scheme (I-Type Arrangement)
SLD with Breaker & Half Scheme, Electrical Layout Plan (for I-Type Dwg.No. 8.30
arrangement with 24m bay width) and Electrical Sectional Elevation

31 Typical 220/132/33kV Air Insulated Substation


Double Main & Transfer Scheme at 220 kV & 132 kV level Dwg.No. 8.31
and Main & transfer Scheme at 33 kV level : Electrical
Layout Plan and Electrical Sectional Elevation for 220 kV,
132 kV & 33 kV system

32 Typical 220/132/33kV Air Insulated Substation with provision for conversion


to Double Main & Transfer Scheme at 220kV & 132kV level
SLD with Main & Transfer Scheme at 220kV, 132kV and 33kV levels Dwg.No. 8.32
Electrical Layout Plan and Electrical Sectional Elevation for 220kV, 132kV
& 33kV system

33 Typical 220kV layout with Double Main & Transfer (DMT) bus Scheme
SLD with DMT Scheme, Electrical Layout Plan and Electrical Sectional Dwg.No. 8.33
Elevation

xix
34 Typical 220kV layout with Double Main Bus scheme (with Pipe/ Rigid
bus)
SLD with Double Main Bus Scheme Dwg.No. 8.34(a)
Electrical Layout Plan (with Pipe/ Rigid bus)
Electrical Sectional Elevation Dwg.No. 8.34(b)

35 Typical 220kV layout with Double Main Bus scheme (with High Level
Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.35

36 Typical 220kV layout with Double Main Bus with breaker by pass
arrangement and bus sectionaliser using isolators (with High Level
Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.36

37 Typical 220kV layout with Double Main Bus scheme with breaker by
pass arrangement and bus sectionaliser using isolators (with Low Level
Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.37

38 Typical 220kV GIS layout with Double Main Bus Scheme


SLD , GIS Layout Plan inside the building Dwg.No. 8.38(a)
Sectional Views Dwg.No. 8.38(b)

39 Typical 220kV layout with Main & Transfer Bus scheme and bus sectionaliser
using isolators (with High Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.39

40 Typical 220kV layout with Main & Transfer Bus scheme and bus sectionaliser
using isolators (with Low Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.40

41 Typical 220kV layout with Single Bus scheme and bus sectionaliser (with
High Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.41

42 Typical 220kV layout with Single Bus scheme and bus sectionaliser (with
Low Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.42

43 Typical 145kV layout with Double Main Bus with breaker by pass
arrangement and bus sectionaliser using isolators (with High Level
Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.43

44 Typical 145kV layout with Double Main Bus scheme with breaker by
pass arrangement and bus sectionaliser using isolators (with Low Level
Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.44

xx
45 Typical 145kV layout with Main & Transfer Bus scheme and bus sectionaliser
using isolators (with High Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.45

46 Typical 132/33kV Air Insulated Substation


SLD with Main & Transfer Scheme at 132kV and 33kV levels with bus Dwg.No. 8.46(a)
sectionalisers using isolators
Electrical Layout Plan for 132kV & 33kV system Dwg.No. 8.46(b)
Electrical Sectional Elevation for 132kV & 33kV system Dwg.No. 8.46(c)
Electrical Sectional Elevation including bus sectionaliser Dwg.No. 8.46(d)

47 Typical 145kV layout with Main & Transfer Bus scheme and bus sectionaliser
using isolators (with Low Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.47

48 Typical 145kV layout with Main & Transfer Bus scheme with splitting of
transfer bus
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.48

49 Typical 145kV layout with Single Bus scheme and bus sectionaliser (with
High Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.49

50 Typical 145kV layout with Single Bus scheme and bus sectionaliser (with
Low Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.50

51 Typical 66kV layout with Double Main Bus scheme with breaker by pass
arrangement and bus sectionaliser using isolators (with High Level
Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.51

52 Typical 66kV layout with Double Main Bus scheme with breaker by
pass arrangement and bus sectionaliser using isolators (with Low Level
Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.52

53 Typical 66kV layout with Double Main Bus schemer


SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.53

54 Typical 66kV layout with Main & Transfer Bus scheme and bus sectionaliser
using isolators (with High Level Arrangement)
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.54

55 Typical 66kV layout with Main & Transfer Bus scheme and bus sectionaliser
using isolators (with Low Level Arrangement)
SLD, Electrical Layout Plan and Sectional Elevation Dwg.No. 8.55
56 Typical 66kV layout with Single Bus scheme wit bus sectionalisers (with
High Level Arrangement)

xxi
SLD , Electrical Layout Plan and Sectional Elevation Dwg.No. 8.56

57 Typical 66kV layout with single Bus scheme with bus sectionaliser (with
Low Level Arrangement)
SLD, Electrical Layout Plan and Sectional Elevation Dwg.No. 8.57

58 Typical 33kV layout with Double Main Bus scheme and bus sectionaliser
using isolators (with High Level Arrangement)
SLD, Electrical Layout Plan and Sectional Elevation Dwg.No. 8.58

59 Typical 33kV layout with Double Main Bus scheme and bus sectionaliser
using isolators (with Low Level Arrangement)
SLD, Electrical Layout Plan and Sectional Elevation Dwg.No. 8.59

60 Typical 33kV layout with Main & Transfer Bus scheme and bus sectionaliser
using isolators (with High Level Arrangement)
SLD, Electrical Layout Plan and Sectional Elevation Dwg.No. 8.60

61 Typical 33kV layout with Main & Transfer Bus scheme and bus sectionaliser
using isolators (with Low Level Arrangement)
SLD, Electrical Layout Plan and Sectional Elevation Dwg.No. 8.61

62 Typical 33 kV layout with Single Bus scheme and bus sectionaliser (with
High Level Arrangement)
SLD, Electrical Layout Plan and Sectional Elevation Dwg.No. 8.62

63 Typical 33 kV layout with Single Bus scheme and bus sectionaliser (with
Low Level Arrangement)
SLD, Electrical Layout Plan and Sectional Elevation Dwg.No. 8.63

xxii