Analysis of Maida
Analysis of Maida
shall pass
through 212
micron IS sieve
(70 mesh)
Procedure:
1. Heat a clean dry Petridis in oven for 30 minutes and cool and dry.
2. Take weighed 2 g sample in Petridis and keep in the oven at 1300C for 1 hr.
3. Remove Petridis and cool in the desiccator and reweigh.
4. Moisture percent is calculated on the basis of mass.
Calculation:
100 x (M 1−M 2 )
Moisture percent by mass = M 1−M
Where,
M = Mass in gm of empty dish.
M1 = Mass in gm of the dish with the sample before drying.
M2= Mass in gm of the dish with sample after drying.
Procedure:
Where,
M = Mass in gm of empty dish in which wet gluten was taken for drying.
M1 = Mass in gm of dish + gluten after drying
M2 = Mass in gm of the sample
A x 100
Gluten percent by mass on dry basis =
100−M
Where,
A = Gluten percent by mass
M = Percent of moisture in sample
Calculation:
A x N x 24.52
Alcoholic acidity with 90% alcohol calculated as H2SO4 on dry basis =
W
Where,
A = Volume in ml of the standard sodium hydroxide solution used in titration / Titre Value
N = Normality of NaOH
W = Weight in gram of sample
Result: