For the latest prices, please check AutomationDirect.com.

1-800-633-0405

Datalogic
Safety Laser Scanners
Datalogic Safety Laser Scanners provide a cost-effective way to safeguard static
applications such as robot cells and moving applications such as automatic guided
vehicles (AGVs). They are also ideal for providing safe access to potentially dangerous
locations or areas.
The Safety Laser Scanners are configurable to meet a wide range of area protection
needs. They features a 275-degree viewing window and allow for several user-definable
zones of protection.
These scanners can also be configured to filter out dust in order to eliminate false trips.

Features
• 275° viewing window

3
Easy programming with intuitive Graphic User Interface (GUI)
• Three levels of advanced dust filtering configurable via GUI
• Can be installed to monitor either horizontally or vertically YEAR
• Configurable warning areas extending up to 40m [131.23 ft] out
• Two distinct and assignable warning signals
• Muting capability for vertical installations
• Three I/O points, each configured either as input or output via
GUI

Datalogic Safety Laser Scanner Selection Guide


Part Number Price Safe Operating Range Resolution Safe Operating Angle Angular Resolution Dimensional Drawing
SLS-SA3-08 $2,102.00 Up to 3m [9.84 ft] See Detection/Operating Range Chart 275° 0.1° PDF
SLS-SA5-08 $2,558.00 Up to 5.5 m [18.04 ft] See Detection/Operating Range Chart 275° 0.1° PDF

Detection / Operating Range*


SLS-SA3-08 SLS-SA5-08
30mm [1.18 in] 2.5 m [8.20 ft] 2.5 m [8.20 ft]
40mm [1.57 in] 3m [9.84 ft] 3m [9.84 ft]
50mm [1.97 in] 3m [9.84 ft] 4m [13.12 ft]
70mm [2.76 in] 3m [9.84 ft] 5.5 m [18.04 ft]
150mm [5.91 in] 3m [9.84 ft] 5.5 m [18.04 ft]
* Minimum operating range is 50mm [2.0 in]

General Specifications
Supply Voltage 24Vdc ± 20%
Safety Outputs (OSSD) 0.25 A max / each OSSD
Operating Temperature -10 to 50 °C [14 to 122 °F]
Humidity Up to 95% (no condensation)
Safety Category Type 3, SIL 2, Pld
PFHd 6.38 x 10-8
Response Time Varies based on configuration(min: 62ms)
MTTFd 61 years
DCavg 96.6%
Degree of Protection IP65
Power Consumption 8W
Weight 2.92 lb [1.32 kg]
M12 8-pin QD (Power and I/O)
Connections M12 4-pin QD (Ethernet - configuration
only)
Datalogic Safety Laser Scanners can manage two simultaneous
Maximum Connection Length 25m [82.02 ft] warning zones and one safe zone. Safe zones can extend up to
Warning Zone Operating
40m [131.2 ft] 5.5 m [18.04 ft], depending on the model, over an angle of 275
Range degrees. Warning zones can extend 40m [131.2 ft].
Certifications TUV, CE, cULus

www.automationdirect.com Safety Electrical Components tESC-40


For the latest prices, please check AutomationDirect.com.
1-800-633-0405

Datalogic
Safety Laser Scanners
I/O Point Options (only three may be selected)
Type I/O Description Notes
Reset
Restart
Reset/Restart
EDM
Area Switch 1 Two area zones can be specified using Up to six area zones can be specified using
Area Switch 2 Area Switch 1 and 2 Area Switch 1, 2, and 3
(When using four or more area zones, consult hardware
Inputs Area Switch 3 manual for info on zone set switching)
Warning 1
Warning 2
Muting 1
In order to activate muting both muting inputs must be used
Muting 2
Muting Enable Can be used in combination with muting function
Override Can be used in combination with muting function
Muting Lamp Can be used in combination with muting function
Override Status Can be used in combination with muting function
Outputs
Alarm 1 Clean Window Alarm
Alarm 2 General Fault Alarm

Connection Diagrams
Connection (M12 8-pin) Connection (M12 D-coded Ethernet)
Pin Color* Description Pin Signal
1 White Selectable I/O (by GUI) 1 TxD+, transmit data +
2 Brown 24VDC 2 RxD+, receive data +
3 Green Selectable I/O (by GUI) 3 TxD-, transmit data -
4 Yellow Selectable I/O (by GUI) 4 RxD-, receive data +
5 Gray Safety Output (OSSD)
6 Pink Safety Output (OSSD)
7 Blue 0V
8 Red Ground
* This connection chart is for 292 series 8-pin cables

www.automationdirect.com Safety Electrical Components tESC-41


For the latest prices, please check AutomationDirect.com.
1-800-633-0405

Datalogic
Safety Laser Scanners
Connection Example

OSSD/Light Curtain
Safety Relay
for example
SCR31P-280003
SCR31P-280003-P
LG5925-48-900-61
or similar

M12 8-Pin Cable


(See recommended items
for cable options)

Area Scanner
SLS-SA5-08
SLS-SA3-08

D-coded Ethernet
Quick-Disconnect Cable
for example
CAB-ETH-M01
CAB-ETH-M03
CAB-ETH-M05
or similar

www.automationdirect.com Safety Electrical Components tESC-42


For the latest prices, please check AutomationDirect.com.
1-800-633-0405
Datalogic
Safety Laser Scanners
Accessories
Datalogic Laser Sentinel Area Scanner Accessories Selection Chart
Part Number Price Description Weight (kg [lb]) Dimensional Drawing
SLS-BRACKET-A $96.00 Bracket, Mounting, Pitch and Roll Regulation Bracket System 0.53 [1.17] PDF
SLS-BRACKET-B $61.00 Bracket, Mounting, Pitch Regulation Bracket System 0.24 [0.53] PDF
SLS-BRACKET-C $35.50 Bracket, Mounting, Head Protective Bracket 0.47 [1.04] PDF
SLS-WINDOW $263.00 Lens, SLS, Replacement Window 0.22 [0.49] PDF

BRACKET WITH PITCH AND ROLL ADJUSTMENT EXAMPLE OF AN


ASSEMBLED UNIT
WITH TWO BRACKETS
INSTALLED

SLS-BRACKET-A

SLS-BRACKET-A assembled with SLS-SA5-08

BRACKET WITH PITCH ADJUSTMENT


SLS-BRACKET-A
and SLS-BRACKET-C
assembled with SLS-SA5-08

REPLACEMENT WINDOW

SLS-BRACKET-B
SLS-BRACKET-B assembled with SLS-SA5-08

HEAD PROTECTIVE BRACKET SLS-WINDOW

SLS-BRACKET-C SLS-BRACKET-C assembled with SLS-SA5-08

www.automationdirect.com Safety Electrical Components tESC-43


For the latest prices, please check AutomationDirect.com.
1-800-633-0405

Datalogic – Ethernet Cables

Datalogic Communication Cables


Part Number Price Description
CAB-ETH-M01 $52.00 Datalogic cable, Ethernet, PVC jacket, shielded, 1m [3.28 ft] cable length, M12 4-pin male D-coded to RJ45
CAB-ETH-M03 $63.00 Datalogic cable, Ethernet, PVC jacket, shielded, 3m [9.84 ft] cable length, M12 4-pin male D-coded to RJ45
CAB-ETH-M05 $75.00 Datalogic cable, Ethernet, PVC jacket, shielded, 5m [16.40 ft] cable length, M12 4-pin male D-coded to RJ45

CAB-ETH-M01 CAB-ETH-M03 CAB-ETH-M05

Diagrams

Pin assignment M12 male connector, Connector pin assignment plug RJ45
4-pos., D-coded, male side

Cable cross section

www.automationdirect.com Safety Electrical Components tESC-19


For the latest prices, please check AutomationDirect.com.
1-800-633-0405

Safety Products
Warning: Safety products sold by AutomationDirect are Safety components only. The purchaser/installer is solely responsible for the application of these components and
ensuring all necessary steps have been taken to assure each application and use meets all performance and applicable safety requirements and/or local, national and/or
international safety codes as required by the application. AutomationDirect cannot certify that our products, used solely or in conjunction with other AutomationDirect
or other vendors’ products, will assure safety for any application. Any person using or applying any products sold by AutomationDirect is responsible for learning the
safety requirements for their individual application and applying them, and therefore assumes all risks, and accepts full and complete responsibility, for the selection and
suitability of the product for their respective application.

AutomationDirect does not provide design or consulting services, and cannot advise whether any specific application or use of our products would ensure compliance
with the safety requirements for any application.

www.automationdirect.com Safety Electrical Components tESC-163