M18x1
24
S51-MA/MR SERIES If necessary reduce sensitivity in order to detect very small targets. In
M12
order to improve alignment, repeat the procedure detailed above whilst
progressively reducing the sensitivity.
CABLE VERSION
INSTRUCTION MANUAL 4
L 14.5 10
Setting of S51-…F00/G00
MODELS
Position the sensors on opposite sides.
B01/C01/F00 A00/C10/G00 Move the sensor both vertically and horizontally, determine the power on
and off points of the yellow LED (OUT) and then mount the sensor in the
Ø4
L 67 57 middle of the defined points.
X 43 38
RADIAL VERSION Setting of S51-…C01
CONTROLS 14.5 X Turn the sensitivity trimmer to minimum: the yellow A C
OUTPUT LED (S51-…A00/B01/C01/C10/C20/F00) LED is OFF.
TRIMMER B
The yellow LED ON indicates that the NO output status is closed. Position the target to detect in front of the sensor.
Turn the sensitivity trimmer clockwise until the yellow MIN MAX
24
M18x1
Remove the target, the yellow LED turns OFF.
M12
The green LED indicates that the sensor is operating. OUTPUT LED
POWER ON LED (S51-...G00) Turn the sensitivity trimmer clockwise until the yellow LED turns ON
TRIMMER (S51-…B01/C01) (Background detected state, pos.B).
The trimmer can be used to adjust sensitivity; the operating distance The trimmer reaches the maximum level if the background is not
increases turning the trimmer clockwise. 4 detected.
L 14.5
MODELS Turn the trimmer to the intermediate C position, between the two A and
WARNING: The trimmer rotation is limited to 270°. B01/C01/F00 A00/C10/G00 B positions.
Do not apply excessive torque beyond the maximum and minimum
L 79 69
positions (max 40 Nmm). X 43 38 Setting of S51-…C10/C20
mm The operating distance range of these sensors is factory preset: please
consider this feature when positioning.
INSTALLATION TECHNICAL DATA TEST FUNCTION (S51-…G00)
The sensor can be fixed by means of the M18x1 threaded body through
a ∅ 18 mm hole, using the two CH.24 nuts enclosed (22 Nm maximum S51-MA AXIAL VERSION S51-MR RADIAL VERSION The TEST+ and TEST- inputs can be used to inhibit the emitter and
tightening torque). Power supply: 10 … 30 Vdc (limit values) verify that the system is correctly operating.
Ripple: 2 Vpp max. The receiver output should switch when the test is activated while the
Various orientable fixing brackets are available to ease the sensor Current consumption beam is uninterrupted. The inputs activating voltage range is 10 … 30
positioning (please refer to the accessories listed in the general 30 mA max. Vdc, whilst respecting the polarity.
catalogue). (output current excluded): The emission is switched off connecting TEST+ to Vdc and TEST- to
The operating distance is measured from the Outputs: N.O.; PNP or NPN (short circuit protection) 0V.
front surface of the sensor lens. Output current: 100 mA max.
C models: To improve the detection, the Output saturation voltage: 2 V max. EX-II-3-D T6
object has to be moved closer or further away Temperature class: T6 (<85°C)
from the front surface of the sensor lens.
Response time: 1 ms (4 ms mod.F00)
Max. Power consumption: 900 mW at 30 Vdc
Switching frequency: 500 Hz (120 Hz mod.F00)
Max. Internal capacitance: 170 nF
In case of lateral translation, the object must OUTPUT LED (YELLOW) mod.G00 excluded Internal inductance: negligible
move as indicated in the figure. Indicators:
POWER ON LED (GREEN) (mod.G00)
Setting: sensitivity trimmer (mod.B01/C01)
CONNECTIONS Operating temperature: -25 … 55 °C
Storage temperature: -25 … 70 °C DECLARATION OF CONFORMITY
The connections are compliant to the EN 60947-5-2 standard.
Insulating strength: 500 Vac 1 min., between electronics and housing We DATALOGIC AUTOMATION declare under our sole responsibility
Insulating resistance: >20 MΩ 500 Vdc, between electronics and housing that these products are conform to the 2004/108/CE and successive
S51-…A00/B01/C01/C10/C20/F00 S51-…G00 amendments.
BROWN 1 BROWN 1
A00: 0.1…3.5 m on R2 A00: 0.1…2.5 m on R2
+ 10 … 30 Vdc + 10 … 30 Vdc
B01: 0.1…2.5 m on R2 B01: 0.1…2.0 m on R2 WARRANTY
Operating distance DATALOGIC AUTOMATION warrants its products to be free from
WHITE 2 WHITE 2 C01: 1…40 cm C01: 1…30 cm
DARK- / LIGHT+ * TEST + (typical values): defects.
C10: 0…10 cm / C20: 0.2…10 cm C10: 0…8 cm DATALOGIC AUTOMATION will repair or replace, free of charge, any
BLACK 4 BLACK 4
N.O. OUTPUT TEST - F00/G00: 0…18 m F00/G00: 0…15 m product found to be defective during the warranty period of 36 months
BLUE 3 BLUE 3 Emission type: RED (660 nm) (mod.B01) / INFRARED (880 nm) (mod.A00/C01/C10/C20/G00) from the manufacturing date.
0V 0V
Ambient light rejection: according EN 60947-5-2 This warranty does not cover damage or liability deriving from the
improper application of DATALOGIC AUTOMATION products.
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
* in case of white wire or pin 2 not connected the sensor works in
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27) DATALOGIC AUTOMATION
LIGHT mode for proximity models (C01/C10/C20) and in DARK mode
for retroreflex (A00/B01) and receiver (F00). white wire or pin 2 connected to +10…30V LIGHT mode; to 0V DARK mode
LIGHT/DARK selection: white wire or pin 2 not connected LIGHT mode (mod.C01/C10/C20);
DARK mode (mod.A00/B01/F00)
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
M12 CONNECTOR Housing material: Nickel-plated brass DATALOGIC AUTOMATION reserves the right to make modifications and
Lens material: PMMA improvements without prior notification.
2 1 Mechanical protection: IP67 Type 1 enclosure Datalogic and the Datalogic logo are registered trademarks of Datalogic
Connections: 2 m cable ∅ 4 mm / M12 - 4 pole connector S.p.A. in many countries, including the U.S.A. and the E.U.
3 4 Weight: 110 g. max. cable vers. / 60 g. max. connector vers. 826001256 Rev.G © Copyright Datalogic 2007-2011