Designing better careTM

for infection control


MIDMARK TABLETOP STERILIZERS
SHORTER CYCLES, LONGER LIFE: SAFE:
our validated and quicker programs multiple sensors check working
ensure long life to your sterilizer. parameters adapting cycle times to
PERFECT FOR YOUR NEEDS: internal and external conditions.
chambers contain 6, 18, 23 or 60 litres ACCURATE :
and are made of thick one-piece moulded the integrated water quality sensor
AISI 304 steel and AISI 316 for 60 L. constantly monitors the water quality.
TROUBLE FREE: Only good quality water ensures a
intelligent self-checking system alerts perfect sterilization and long life for your
about maintenance needs. instruments and autoclave.

EFFICIENT: SIMPLE:
more than 10 pre-set validated easy to use by everyone, easy to service
sterilizations programs.

2
VSL - VACUUM SAFETY BUILT-IN THERMAL WATER QUALITY SENSOR:
LOCKING: PRINTER:

door locking is motor operated an automatic print-out records our sterilizers are additionally
and the chamber is vacuum- the entire procedure, thereby protected by the inclusion of a
sealed right after. VLS providing a permanent record water quality sensor, as stan-
technology guarantees total of every sterilization cycle. The dard. The quality of the water is
safety, greater ease of handling paper printout can then be kept therefore constantly monitored.
and reliable self regulation of and attached to your files for a The display informs the user
the hatch. complete and accurate record. whether water used for sterili-
zation is good.

USB PORT: MULTILINGUAL & USER- WATER PURIFICATION


FRIENDLY INTERFACE: SYSTEM:

automatic digital cycle re- just four buttons for simpler with built-in ROSI (ROSI), tri-
cording on USB stick can be navigation to all sterilization cartridge water purification
downloaded on your PC using options. The LCD display shows system, your autoclave can
our proprietary software (optio- current information about your be connected directly to your
nal). sterilization cycles and alerts on practice water supply, always
errors or service needs. ensuring good water to your
sterilization process (optional).

3
MIDMARK 6 L
Sterilisation Table
B6 S6

DISPLAYED #, STERIZABLE LOAD


TOTAL TOTAL WRAPPED/
TEMPERATURE AND TYPE TYPE Load in (..) is sterizable
TIME TIME OPEN
NAME only in B-Class
HELIX - B&D 35’
TEST 19’
B&D only 
TEST TEST N/A
VACUUM
TEST 15’ 15’ 
121 °C Solid
HOLLOW WRAPPED 31’ 45’
Small porous 
S Simple hollow
134 °C
HOLLOW WRAPPED 22’ 35’
Narrow lumen
Multiple casing 
121 °C
HOLLOW OPEN 27’
Solid 
Small porous
134 °C
HOLLOW OPEN B 14’ NOT PRESENT
Simple hollow

134 °C Load related to
PRION 34’
Creutzfeldt-Jakob disease 
121 °C
POROUS 38’ 50’
Small sized porous 
S +
134 °C
POROUS 30’ 40’
(Full porous)

121 °C
SOLIDS OPEN 21’
Solid 
Simple hollow
134 °C
SOLIDS OPEN S 12’ NOT PRESENT 
134 °C Solid
SOLIDS WRAPPED 12’
Simple hollow 
134 °C
RAPID NOT PRESENT S 32’ Solid 
NOTE: Narrow lumen is an item open on one
Solids Solids side with length equal to 5 times (or more)
wrapped: 1 kg wrapped: 1 kg the diameter.
WEIGHT unwrapped: 1.8 kg unwrapped: 1.8 kg Times are calculated in conditions of
pre-warmed chamber.
Porous: 0.5 kg Porous: 0.5 kg

MIDMARK STERILIZERS ARE SUPPLIED WITH:


4
TRAYS HOLDER | ALUMINIUM TRAYS | LOADING AND DISCHARGE TUBES | CLEANING SPONGE | TRAYS REMOVAL HANDLE
B6 S6
REFERRING TO KRONOS S6

pre and
TYPE OF
fractionated post VACUUM
vacuum

 - INTEGRATED STEAM GENERATOR

Bowie&Dick
Bowie&Dick TEST

TECHNICAL DATA
Helix PROGRAMS
Vacuum
Vacuum

6L BUILT-IN
PRINTER

M.T.S MEMORY TEST SYSTEM


WATER QUALITY SENSOR

CONNECTION TO DATA
LOGGER

optional INTERNAL USB DATA LOGGER

OVERALL
450Wx590Dx345H mm MEASURES

ø170 x 265 mm CHAMBER SIZE

nr. 3 aluminium trays:


1 tray 150Wx240Dx19H mm TRAY SIZES
2 trays 115Wx240Dx19H mm

SUPPLY
230V ± 10% VOLTAGE

MAINS
50-60 Hz FREQUENCY

RATED
2500 W 1500 W POWER
5
B6
MIDMARK 18 L

Sterilisation Table

B18 S18 N18

DISPLAYED #, STERIZABLE LOAD


TOTAL TOTAL TOTAL WRAPPED/
TEMPERATURE AND TYPE TYPE TYPE Load in (..) is sterizable
TIME TIME TIME OPEN
NAME only in B-Class
HELIX - B&D 28’
TEST 25’
B&D only 
TEST TEST N/A
VACUUM
TEST 15’ 15’ 
121 °C Solid
HOLLOW WRAPPED 40’ 48’ Small porous 
Simple hollow
134 °C B NOT PRESENT
+
HOLLOW WRAPPED 29’ 37’ (Narrow lumen)
(Multiple casing)

121 °C
SOLIDS WRAPPED 37’ 45’ Solid
+

S
134 °C (Small porous)
SOLIDS WRAPPED 25’ 34’ (Simple hollow) 
134 °C
PRION 44’ 52’ N 45’
Load related to
Creutzfeldt-Jakob disease
/
(B-S18/N18)
S
121 °C
POROUS
B 50’ 58’
Small sized porous 
NOT PRESENT +
134 °C
POROUS 40’ 48’
(Full porous)

121 °C Solid
RAPID 31’ 39’ 33’
+ 
S N (Small porous)
134 °C
RAPID 20’ 28’ 23’
(Simple hollow)

134 °C Solid
HOLLOW OPEN Simple hollow
B 26’ 34’ NOT PRESENT
+ 
(Narrow lumen)
121 °C
SOLIDS OPEN 43’ 
NOT PRESENT NOT PRESENT N Solid
134 °C
SOLIDS OPEN 31’ 

Solids Solids
wrapped: 2.5 kg wrapped: 1 kg Solids using
WEIGHT unwrapped: 4 kg unwrapped: 2.5 kg RAPID: 1.5 kg
others: 3 kg
Porous: 1 kg Porous: 0.5 kg

NOTE: Narrow lumen is an item open on one side with length equal to 5 times (or more) the diameter.
Times are calculated in conditions of pre-warmed chamber.

6
B18 S18 N18

Thermo-
pre and TYPE OF
fractionated dynamic VACUUM
post vacuum
vacuum

INTEGRATED
STEAM
GENERATOR

TECHNICAL DATA
BUILT-IN PRINTER

18 L
 M.T.S MEMORY
TEST SYSTEM

WATER
QUALITY
SENSOR

CONNECTION TO
EXTERNAL DATA
LOGGER

INTERNAL USB
DATA LOGGER

optional

INTEGRATED
WATER
PURIFICATION
SYSTEM “ROSI”

OVERALL
505Wx615Dx400H mm MEASURES

ø236x381,5 mm CHAMBER SIZE

nr. 4 aluminium trays:


TRAY SIZES
185Wx285Dx18H mm

SUPPLY
230 V ± 10% VOLTAGE

MAINS
50-60 Hz FREQUENCY

RATED
2400 W POWER
7
B18
MIDMARK 23 L

Sterilisation Table

B23 S23 N23

DISPLAYED #, STERIZABLE LOAD


TOTAL TOTAL TOTAL WRAPPED/
TEMPERATURE AND TYPE TYPE TYPE Load in (..) is sterizable
TIME TIME TIME OPEN
NAME only in B-Class
HELIX - B&D 38’
TEST 35’
B&D only 
TEST TEST N/A
VACUUM
TEST 15’ 15’ 
121 °C Solid
HOLLOW WRAPPED 50’ 58’ Small porous 
Simple hollow
134 °C B NOT PRESENT
+
HOLLOW WRAPPED 39’ 47’ (Narrow lumen)
(Multiple casing)

121 °C
SOLIDS WRAPPED 47’ 55’ Solid
+

S
134 °C (Small porous)
SOLIDS WRAPPED 35’ 44’ (Simple hollow) 
134 °C
PRION 54’ 52’ N 55’
Load related to
Creutzfeldt-Jakob disease
/
(B-S23/N23)
S
121 °C
POROUS
B 60’ 68’
Small sized porous 
NOT PRESENT +
134 °C
POROUS 50’ 58’
(Full porous)

121 °C Solid
RAPID 41’ 49’ 43’
+ 
S N (Small porous)
134 °C
RAPID 30’ 38’ 33’
(Simple hollow)

134 °C Solid
HOLLOW OPEN Simple hollow
B 36’ 44’ NOT PRESENT
+ 
(Narrow lumen)
121 °C
SOLIDS OPEN 53’ 
NOT PRESENT NOT PRESENT N Solid
134 °C
SOLIDS OPEN 41’ 

Solids Solids
wrapped: 3.5 kg wrapped: 2 kg Solids using
WEIGHT unwrapped: 4.5 kg unwrapped: 3.5 kg RAPID: 2.5 kg
others: 4.5 kg
Porous: 1.5 kg Porous: 0.5 kg

NOTE: Narrow lumen is an item open on one side with length equal to 5 times (or more) the diameter.
Times are calculated in conditions of pre-warmed chamber.

8
B23 S23 N23

pre and TYPE OF


fractionated no vacuum VACUUM
post vacuum

INTEGRATED
STEAM
GENERATOR

TECHNICAL DATA
BUILT-IN
PRINTER

23 L

 M.T.S MEMORY
TEST SYSTEM

WATER
QUALITY
SENSOR

CONNECTION
TO EXTERNAL
DATA
LOGGER

INTERNAL USB
DATA LOGGER

optional

INTEGRATED
WATER
PURIFICATION
SYSTEM “ROSI”

OVERALL
505Wx690Dx400H mm MEASURES

ø236x530 mm CHAMBER SIZE

nr. 4 INOX trays:


TRAY SIZES
185Wx440Dx19H mm

SUPPLY
230 V ± 10% VOLTAGE

MAINS
50-60 Hz FREQUENCY

RATED
2400 W 9
POWER
B23
MIDMARK 60 L

SMALL
FOOTPRINT
HUGE
CAPACITY

CAPACITY 60 LITERS
BUILT-IN OSMOTIC SYSTEM
DOUBLE VACUUM PUMP
DOUBLE MOTOR-OPERATED LOCKING
SYSTEM
INTEGRATED USB STORAGE DEVICE
ON BOARD PRINTER
QUIKSTEAM PATENTED TECHNOLOGY
ADDITIONAL DRYING OPTION
« START DELAY » OPTION
B/S/N-CLASS CYCLES INCLUDED

MIDMARK 60 L STERILIZERS ARE SUPPLIED WITH:


10 TRAYS HOLDER | ALUMINIUM TRAYS | CLEANING SPONGE | 1 SILICONE - INSULATED GLOVES | TUBES AND FITTING
CD SOFTWARE | OSMO3 PROTECTION FILTER
Sterilisation Table
B60 B60 SI
DISPLAYED #, TOTAL TOTAL WRAPPED/
TYPE TYPE STERIZABLE LOAD
TEMPERATURE AND NAME TIME TIME OPEN
1 HELIX - B&D
TEST
TEST
75’
TEST
45’
N/A

2 VACUUM
TEST
15’ 15’ 
3 121 °C Solid
HOLLOW WRAPPED
115’ 73’
Small porous 
B B Simple hollow
4 134 °C
HOLLOW WRAPPED 110’ 69’ Narrow lumen
Multiple casing 
5 121 °C
SOLIDS WRAPPED
S
100’
S
60’ Solid
Small porous

6 134 °C
SOLIDS WRAPPED
95’ 59’ Simple hollow

7 134 °C Load related to
PRION
B
135’
B
72’
Creutzfeldt-Jakob disease 
8 134 °C
POROUS
130’ 89’ Full porous 
12 134 °C
SOLIDS OPEN
N 105’ N 68’ Solid 
Solids wrapped: 12 kg
WEIGHT
Porous: 6 kg

NOTE: Narrow lumen is an item open on one side with length equal to 5 times (or more) the diameter.
Times are calculated in conditions of pre-warmed chamber.

B60 B60 SI
fractionated TYPE OF VACUUM

-  INTEGRATED STEAM
GENERATOR

Bowie&Dick/Helix/Vacuum TEST PROGRAMS

BUILT-IN PRINTER
TECHNICAL DATA

M.T.S MEMORY
TEST SYSTEM

INTERNAL USB
DATA LOGGER

 CONNECTION TO
DATA LOGGER

WATER QUALITY
SENSOR

INTEGRATED WATER
PURIFICATION SYSTEM

135 kg 138 kg WEIGHT

OVERALL MEASURES
655Wx850Dx755H mm
(WITHOUT CABINET)

ø350x622 mm CHAMBER SIZE

nr. 4 aluminium trays:


2 trays 310Wx550Dx25H mm TRAY SIZES
2 trays 220Wx550Dx25H mm

230 V ± 10% (1 phase) 400 V ± 10% (3 phases) SUPPLY VOLTAGE

50-60 Hz MAINS FREQUENCY


11
11 Amp 13 Amp per phase RATED POWER
NOTE: The autoclave is a device designed for water steam sterilization of small professional tools and equipment and widely used
for medical purposes, in general practitioners’ and dentists’ surgeries, in facilities dedicated to personal hygiene and care and in
veterinary surgeries. It is also used to sterilize materials and equipment intended to come into contact with blood or bodily fluids,
such as instruments used by beauticians, tattooists, body piercers and hairdressers. The very specific sterilization loads used in these
sectors of application require a diversification of the requirements concerning performance characteristics for sterilization cycles. It
is therefore recommended that the device be used by suitably trained professionals.

NOTE: Specifications may change without prior notice.

Manufactured by NEWMED

Via Lenin, 79/A


42020 Quattro Castella (RE) - Italy

Phone: +39 0522 875166


E-mail: [email protected]
WWW.MIDMARK.COM

MIDMARK STERILIZERS ARE IN COMPLIANCE WITH:

93/42/CEE Medical Device Directive (MDD)

2014/68/EU Pressure Equipment Directive

2012/19/EU Waste electrical and electronic equipment (WEEE)

EN 13060 Small steam sterilizers

CEI EN 61010-1 Safety prescriptions for electrical, measuring,


control and laboratory equipment

CEI EN 61010-2-040 Safety requirements for electrical equipment for


M.08.12_MIEN Rev. 01 (13/05/21)

measurement, control, and laboratory use - Part 2-040:


Particular requirements for sterilizers and washer
disinfectors used to treat medical materials

CEI EN 61326-1 Electrical equipment for measurement, control and


laboratory use - Prescriptions of electromagnetic
compatibility