Chapter 2 (DiodeRectifier UNITEN)
Chapter 2 (DiodeRectifier UNITEN)
Single-phase, full wave rectifier R load R-L load, Controlled R, R-L load continuous and discontinuous current mode Three-phase rectifier uncontrolled controlled
Rectifiers DEFINITION: Converting AC (from mains or other AC source) to DC power by using power diodes or by controlling the firing angles of thyristors/controllable switches. Basic block diagram
Input can be single or multi-phase (e.g. 3-phase). Output can be made fixed or variable Applications: DC welder, DC motor drive, Battery charger,DC power supply, HVDC
Introduction The single-phase diode rectifiers are the simplest static converters of electrical power. Power diodes employed in the circuits are uncontrolled semiconductor power switches. Diode as we have already seen, turns-on when a positive voltage is applied at its anode with the respect to its cathode. In most applications, the rectifier circuits are supplied from the utility source. In the analysis of diode rectifier circuits in this section we will assume that diodes are ideal. Single-Phase, half-wave with R- load
RMS Voltage
DC voltage is fixed at 0.318 or 31.8% of the peak value. RMS voltage is reduced from 0.707 (normal sinusoidial RMS) to 0.5 or 50% of peak value. Half wave is not practical because of the high distortion supply current. The supply current contains DC component that may saturate the input transformer.
where: if, in are known as forced and natural response, respectively. From the diagram, forced response is:
R-L Load
R-L waveform
where P is the real power supplied by the source, which is equal to the power absorbed by the load. S is the apparent power supplied by the source i.e.
Operation of FWD Note that both D1and D2cannot be turned on at the same time. For a positive cycle voltage source, D1 is on, D2 is off The equivalent circuit is shown in Figure (b) The voltage across the R-L load is the same as the source voltage. For a negative cycle voltage source, D1 is off, D2 is on The equivalent circuit is shown in Figure (c) The voltage across the R-L load is zero. However, the inductor contains energy from positive cycle. The load current still circulates through the R-L path. But in contrast with the normal half wave rectifier, the circuit in Figure (c) does not consist of supply voltage in its loop. Hence the negative part of vo as shown in the normal half-wave disappear FWD- Continuous load current The inclusion of FWD results in continuous load current as shown below Note that the output voltage has no negative part.
10
For the bridge rectifier, the basic observations are as follows: 1. Diodes D1 and D2 conduct together, and D3 and D4 conduct together. Kirchoffs voltage law around the loop containing the source, D1 and D3 shows that D1 and D3 cannot be on at the same time. Same principle applied to D2 and D4. The load current can be positive or zero but never negative. 2. The voltage across the load is +Vs when D1 and D2 are on. The voltage across the load is Vs when D3 and D4 are on. 3. The maximum voltage across a reverse biased diode is the peak value of the source. 4. The current entering the bridge from the source is iD1- iD4, which is symmetric about zero. Therefore, the average source current is zero. 5. The rms source current is the same as the rms load current. The source current is the same as the load current for half of the source period and is the negative of the load current for the other half. The squares of the load and source currents are the same, so the rms currents are equal. 6. The fundamental frequency of the output voltage is 2, where is the frequency of the ac input, since two periods of the output occur for every period of the input. The Fourier series of the output consists of a dc term and the even harmonics of the source frequency.
11
2) Center-tapped circuit
Center-tapped circuit
Center-tapped rectifier requires center-tap transformer. Bridge does not. Center tap requires only two diodes, compared to four for bridge. Hence, per half-cycle only one diode volt-drop is experienced.Conduction losses is half of bridge. However, the diodes ratings for center-tapped is twice than bridge.
12
13
14
15
16
17
CONTROLLED RECTIFIER
18
1 Io = i(t )d 2
The power absorbed by the load
I RMS
1 = [ i 2 (t )d ] 2
19
20
21
22