Body Ported Type

3-Color Display Digital Flow Switch

PF3A7 H Series RoHS

How to Order

PF3A 7 03 H 10 CS M
Type Calibration certificate*8
7 Integrated display Nil None
A*9 Yes

Rated flow range *8 T


 he certificate is in both
English and Japanese.
03 30 to 3000 L/min *9 Made to order
06 60 to 6000 L/min
12 120 to 12000 L/min Unit specification
Nil Units selection function*6
M SI units only*7
Large flow type *6 T
 his product is for overseas use only.
(The SI unit type is provided for use in
Japan in accordance with the New
Thread type Measurement Act.)
Nil Rc *7 Fixed units: Instantaneous flow: L/min
N NPT Accumulated flow: L
F*1 G
Options
*1 ISO 1179-1 compliant
Nil With lead wire with M12 connector (3 m)*5
N Without lead wire with M12 connector
Port size
*5 O
 ptions are shipped together with the product
Port Rated flow range but do not come assembled.
Symbol
size 03 06 12
10 1  — — Output specification
14 1 1/2 —  — Symbol OUT FUNC*2 Applicable monitor unit model
20 2 — —  CS NPN Analog voltage output*3 ⇔ External input*4 PFG300 series
DS NPN Analog current output ⇔ External input*4 PFG310 series
ES PNP Analog voltage output*3 ⇔ External input*4 PFG300 series
FS PNP Analog current output ⇔ External input*4 PFG310 series
*2 A nalog output or external input can be selected by pressing the
buttons. Analog output is set as default setting.
*3 1 to 5 V or 0 to 10 V can be selected by pressing the button. The
default setting is 1 to 5 V.
*4 The accumulated value, peak value, and bottom value can be reset.

Option/Part No.
When only optional parts are required, order with the part number listed below.
Part no. Option Note
ZS-37-A Lead wire with M12 connector Length: 3 m

A 13
Body Ported Type
3-Color Display Digital Flow Switch PF3A7 mH Series
For flow switch precautions and specific product precautions,
refer to the “Operation Manual” on the SMC website.
Specifications
PF3A703H PF3A706H PF3A712H

PF3AH(-L)
Model
Applicable fluid*1 Air, Nitrogen
Fluid
Fluid temperature 0 to 50°C
Detection method Thermal type
Rated flow range 30 to 3000 L/min 60 to 6000 L/min 120 to 12000 L/min
Instantaneous flow 30 to 3150 L/min 60 to 6300 L/min 120 to 12600 L/min
Set point range*2
Accumulated flow 0 to 999,999,999,990 L 0 to 999,999,999,900 L
Flow Smallest settable Instantaneous flow 2 L/min 5 L/min 10 L/min
increment Accumulated flow

Body Ported Type


10 L 100 L
Accumulated volume per pulse
Select from 100 L/pulse or 1000 L/pulse.
(Pulse width = 50 ms)
Accumulated value hold function*3 Intervals of 2 or 5 minutes can be selected.
Rated pressure range 0.1 to 1.5 MPa
Proof pressure 2.25 MPa
Pressure
Pressure loss Refer to the “Pressure Loss” graph on page 24.
Pressure characteristics*4 ±2.5% F.S. (0.1 to 1.0 MPa, 0.5 MPa standard)
Power supply voltage 24 VDC ±10%
Electrical Current consumption 150 mA or less
Protection Polarity protection

PF3AH(-L)
Display accuracy ±3.0% F.S.
Analog output accuracy ±3.0% F.S.
Accuracy Switch output/Display: ±1.0% F.S.
Repeatability
Analog output: ±1.0% F.S.
Temperature characteristics ±5.0% F.S. (Ambient temperature of 0 to 50°C, 25°C standard)
NPN open collector
Output type
PNP open collector
Output mode Select from Instantaneous output (Hysteresis mode or Window comparator mode), Accumulated output, or Accumulated pulse output.

Modular Type
Switch operation Select from Normal or Reversed output.
Max. load current 80 mA
Switch output Max. applied voltage (NPN only) 28 VDC
Internal voltage drop NPN output type: 1 V or less (at load current of 80 mA)
(Residual voltage) PNP output type: 2 V or less (at load current of 80 mA)
Response time*5 Select from 1 s, 2 s, or 5 s.
Hysteresis*6 Variable from 0
Protection Over current protection
Output type Voltage output: 1 to 5 V (0 to 10 V can be selected*8), Current output: 4 to 20 mA
Voltage output Output impedance: Approx. 1 kΩ
Analog output*7 Impedance
Current output Maximum load impedance: Approx. 600 Ω
Response time*9 Linked to the response time of the switch output
Input type No-voltage input: 0.4 V or less
External input*10 Input mode Select from Accumulated value external reset or Peak/Bottom value reset.
Input time 30 ms or longer

PFG300
Reference condition*11 Select from Standard conditions or Normal conditions.
Instantaneous flow L/min, CFM (ft3/min)
Unit*12
Accumulated flow L, ft3
0 to 3150 L/min 0 to 6300 L/min 0 to 12600 L/min
Instantaneous flow
Display range*13 (Flow under 30 L/min is displayed as “0”) (Flow under 60 L/min is displayed as “0”) (Flow under 120 L/min is displayed as “0”)
Accumulated flow*14 0 to 999,999,999,990 L 0 to 999,999,999,900 L
Display
Minimum Instantaneous flow 2 L/min 5 L/min 10 L/min
display unit Accumulated flow 10 L 100 L
LCD, 2-screen display (Main screen/Sub screen)
Display Main screen: Red/Green, Sub screen: Orange
Main screen: 5 digits, 7 segment, Sub screen: 6 digits, 7 segment
Indicator LED OUT indicator: Red LED is ON when output is ON
Enclosure IP65 Function
Withstand voltage 1000 VAC for 1 minute between terminals and housing
Environmental
Insulation resistance 50 MΩ (500 VDC measured via megohmmeter) between terminals and housing
Details
resistance
Operating temperature range Operating: 0 to 50°C, Stored: −10 to 60°C (No freezing or condensation)
Operating humidity range Operating/Stored: 35 to 85% RH (No condensation)
Standards CE/UKCA marking
Piping Piping specification Rc1, NPT1, G1 Rc1 1/2, NPT1 1/2, G1 1/2 Rc2, NPT2, G2
Main materials of parts in contact with fluid Aluminum alloy, PPS, HNBR [Sensor: Pt, Au, Fe, Lead glass (exempted from the RoHS application), Al2O3]
Length of lead wire with connector 3m
Rc 610 g 1190 g 1680 g
Piping
NPT 610 g 1190 g 1680 g
Weight specification
G 630 g 1220 g 1720 g
Lead wire with connector +90 g
*1 A ir quality grade is JIS B 8392-1:2012 [4:6:-] and ISO 8573-1:2010 [4:6:-]. *6 If the flow fluctuates around the set value, the width for setting more than
*2 Set point range will change according to the setting of the zero cut-off function. the fluctuating width needs to be set. Otherwise, chattering will occur.
*3 When using the accumulated value hold function, use the operating conditions to calculate *7 Analog output or external input can be selected by pressing the buttons.
the product life, and do not exceed it. The maximum update limit of the memory device is 1.5 Refer to the graph for analog output.
million times. If the product is operated 24 hours per day, the product life will be as follows: *8 When selecting 0 to 10 V, refer to the analog output graph for the allowable load current.
· 5 min interval: life is calculated as 5 min x 1.5 million = 7.5 million min = 14.3 years *9 The time from when the flow is changed by a step input (when the flow rate
· 2 min interval: life is calculated as 2 min x 1.5 million = 3 million min = 5.7 years changes from 0 to the maximum value of the rated flow range instantane-
If the accumulated value external reset is repeatedly used, the product life ously) until the analog output reaches 90% of the rated flow rate
will be shorter than the calculated life. *10 Analog output or external input can be selected by pressing the buttons.
*4 W hen the pressure range is 1.0 to 1.5 MPa, the pressure characteristics will be ±5% F.S. *11 The flow rate given in the specifications is the value under standard conditions.
(standard pressure is 0.5 MPa). Do not release the OUT side piping port of the product to *12 Setting is only possible for models with the units selection function.
the atmosphere without connecting piping. If the product is used with the piping port re- *13 Display range will change according to the setting of the zero cut-off function.
leased to atmosphere, accuracy may vary. *14 The accumulated flow display is the upper 6-digit and lower 6-digit (total of
*5 The time from when the flow is changed by a step input (when the flow rate 12 digits) display. When the upper digits are displayed, x 106 lights up.
changes from 0 to the maximum value of the rated flow range instantaneously) * Products with tiny scratches, marks, or display color or brightness variations which
until the switch output turns ON (or OFF) when set to be 90% of the rated flow rate do not affect the performance of the product are verified as conforming products.
14 A