Conventional Detector: Optical Smoke
Conventional Detector: Optical Smoke
Optical Smoke
Detector
C-9102
Standard: EN54:7
C-9102 Conventional Optical detector. Utilizing an 8 bit processor to Approval: LPCB, CE-CPD
analyse the data from the active optical smoke detection chamber, to Operating Voltage: 24VDC (12VDC~28VDC)
provide a fast and accurate alarm response with superb false alarm Standby Current: ≤60μA
rejection, due to the embedded algorithms. The detector also has Alarm Current: 10mA≤ I ≤30mA
built-in Drift Compensation to ensure the device remains in top Indicators: Red. Quiet in normal condition. Illuminates
working condition even in demanding environments. steadily in alarm.
Remote Indicator Output: Directly connecting with LED
(built-in 2kΩ resistor in series). Quiet in normal condition.
Features and Benefits Illuminates steadily in alarm.
Maximum Ripple Voltage: 4V (peak-to-peak)
1. Listed to LPCB Alarm Clear: Instantaneous Power-off
2. Sensing chamber for exceptional dust proof ability (5s Max., 2.5VDC Max)
3. Built-in Remote Indicator Output
Power-up Time: ≤10s
4. Twin LED for 360º vision
5. Low profile design Max. Wind Speed: 7.6m/s (1500fpm)
Wiring: Polarized 2-core for detection zone Cable.
Ambient temperature: -10℃~+50℃
Selection of Compatible Control Panels Relative Humidity: ≤95%, non condensing
Ingress Protection Rate: IP23
Compatible with all GST Conventional Panels and GST Intelligent Material and Color of Enclosure: ABS, white (RAL 9016)
Fire Alarm Panels Dimensions: Diameter: 100mm
Height: 56mm (with base)
Mounting Hole Distance: 45mm~75mm
Weight: About 120g
1. When the detector is connected with a conventional fire alarm control panel or an I-9319 addressable zone monitor unit in series, if a P-9907
AEOL is connected to the end of output loop, a 1N5819 Diode should be connected to the detector base.
Used as the detector base, the AEOL is to install a conventional detector on it. The system connection is shown below:
Diode Diode
Addressable Zone Monitor Unit
Fire Alarm Control Panel
Output+ -
+ + -
I-9319
Output-
Remote Indicator
Remote Indicator
Conventional Detector Conventional Detector Conventional MCP P-9907 AEOL
When the AEOL is not used as the detector base, a cover should be added, the system connection is shown below:
Diode Diode
Addressable Zone Monitor Unit
Fire Alarm Control Panel
Output+
+ - + -
I-9319
Output-
2. When the detector is connected with a conventional fire alarm control panel (those within the dotted line are equivalent to a conventional fire
alarm control panel) or an I-9319 Addressable zone monitor unit in series, if an end of line resistor is connected to the end of output loop, then no
diode is connected to the detector base. The system connection is shown below:
Addressable Zone Monitor Unit
Fire Alarm Control Panel
4.7k ΩResistor
Output+
+ - -
+
I-9319
Output-
Maximum 15 detectors can be connected in one zone. Cooperating with end of line device, the compatible panel can monitor the cable for open
circuit and short circuit. Panel will report if any detector is removed. With the AEOL, the functioning of other device will not be affected by the
detector removal.