SC Series Smart Solar Charge Controlle

ECO-SC60A

Manual version: 1. 01
ECO-SC60A

ECO-SC60A 189.3x128x53.1(mm)

In the non-load mode menu:


1) When is long pressed , the first interface entered is for battery type setting, and the flashing one is the
battery type currently selected. Press to select among FLD/GEL/SLD/LI.
2) After selection, short press to enter into over-discharge return and over-discharge voltage settings; or
the first to enter charging voltage setting menu for lithium battery.
3) After parameters have been set, long press for 2 s to save and exit.
Parameters shall be set according to the following rule: over-discharge voltage <over- 3. Precautions:
①If it is 12V system, the bottom left corner of LCD display will show '12V', 24V system will show' 24V',36V
discharge return voltage ≤under-voltage warning <floating charging voltage <boost charging
system will show '36V', 48v system will show '48V'.
return ≤ equalizing charging voltage <overcharge voltage; and two adjacent values shall have ② The first step is to connect the battery. If the connection is made correctly, the controller screen will light up;
a difference greater than 0.5 V. otherwise, check whether the connection is correct.
③ The second step is to connect the solar panel. If sunlight is present and strong enough (the solar panel voltage is
greater than battery voltage), the sun icon on the LCD screen is on; otherwise, check whether the connection is correct
(it's recommended that the operation be performed under the debugging mode).
④ The third step is to connect the load. Connect the load leads to the controller's load output terminal, and the current
shall not exceed the controller's rated current.
⑤As the controller will generate heat during operation, it's recommended that the controller be installed in an
environment with good ventilation conditions.
⑥ Choose cables with large enough capacity for connection, in case too much loss incurred on the lines causes
the controller to misjudge. 189.3x128x53.1(mm)
⑦ The controller has a common positive pole inside. If grounding is needed, ground the positive pole.
⑧ It's important to fully charge the battery regularly. At least once full charging every month is recommended, and
failure to do that may cause permanent damage to the battery. Only when in-flow energy outpaces that out-flow The charging and discharging amp-hrs displays: The decimal point flashes indicating that the
energy can the battery be charged fully. Users shall bear this in mind when configuring the system. 9999.K Ah displayed value has reached its upper limit.
⑨ Check whether the controller's each connection terminal is tightened securely; if not, it may suffer damage when Long press to reset it.
large current passes .