TRADITION AND EXTENSIVE EXPERIENCE - MANUFACTURING INSTRUMENT

TRANSFORMERS SINCE 1947

FLEXIBLE DESIGN - READINESS AND WILLINGNESS TO COMPLY WITH CUSTOMER REQUIREMENTS

LONGEVITY AND RELIABILITY - DESIGNED FOR AT LEAST 50 YEARS OF SERVICE LIFE

AGU
CURRENT TRANSFORMERS
VKU
VOLTAGE TRANSFORMERS

12 to 52 kV - oil insulated

Končar - Instrument Transformers Inc.


Application
Current and voltage instrument transformers are used to step-down
current and voltage (respectively) to defined values, and thus provide
standardized, useable levels of current and voltage in a variety of
power monitoring, measurement and protection applications while
insulating the measurement and protection equipment from high
system voltage.

Performance
• Um: 12 to 52 kV
• All metering and protection classes
• AGU
- In: up to 6000 A
- Short circuit: up to 100 kA (Idyn: 250 kA peak)
- Secondary cores: up to 6
• VKU
- Secondary windings: up to 4
- Single or double pole insulated design

Main Features
• AGU
- Top core design - ensuring low primary winding losses
- Primary and/or secondary transformation ratio reconnection
- Low leakage reactance type
• VKU
- Secondary transformation ratio reconnection
- High thermal overload capability
- Ideal for capacitor bank discharge
• High quality paper-oil insulation
• High-precision measurement accuracy and protection classes with
superior transient response
• Standard ambient temperatures from -35 to +40 °C (extreme ranges
upon request)
• High quality porcelain or composite (silicone shed) insulator
• Extensive experience in seismically active regions
• Minimum oil design and PCB free - environment friendly
• Stainless steel bellows oil expansion system
• Sealing for life - every single transformer is vacuum tested with helium
• Non-corrosive hardware
• Maintenance free
• Explosion-safe design

Accessories
• Terminal for measuring dielectric dissipation factor (tgδ) (optional)
• Secondary winding protection (optional)
- fuses or Micro Circuit Breakers (MCB) for VKU
- surge arresters for AGU
• Oil level indicator (optional for VKU)
• Separate revenue metering secondary terminals sealing
• Internal overpressure indicator (optional)

Quality Assurance
Končar instrument transformers are designed in compliance with IEC, ANSI/IEEE, GOST, AS, IS, CAN, or any other relevant standard.
Product quality is assured through a certified quality standard, the ISO 9001, covering all aspects of design, production and testing.
Končar - Instrument transformers Inc. is ISO 14001 and OHSAS 18001 certified, ensuring environmental and occupational health and safety standards are met.
And most importantly, our tireless ambition to satisfy customers has sealed long lasting quality and reliability onto our product.
AGU VKU AGU VKU AGU VKU AG
VOLTAGE CURRENT VOLTAGE CURRE
TRANSFORMERS TRANSFORMERS TR

DESIGN

Current Transformer (AGU) Voltage Transformer (VKU)


The active part of the current transformer comprises of wound toroidal cores, In the laminated magnetic core is of the closed 3 limb type and is made of
an aluminium or copper primary winding passing through them and paper stacked silicone steel sheets.
insulation. As such, the top core transformer has its minimal length primary The primary winding is made in layers with the interlayer insulation made of
winding and only the low voltage part insulated in paper. Another benefit of high quality insulating paper.
this design is that local saturation is avoided and minimal losses and leakage
Secondary enamelled copper windings are wound with high-grade enamelled
reactance are ensured.
copper wire of large cross-section area, making it capable of withstanding a
Variable transformation ratios are achieved through reconnection on either secondary short circuit.
the primary (HV) and/or the secondary (LV) side.
Moreover, the insulation is tested at higher than nominal test voltages thus
The transformer can accommodate several independent cores which can, additionally contributing to transformer safety.
depending on required accuracy class, be made of cold-rolled grain-oriented
The two pole variant differs from the single pole one only in having an
magnetic steel, soft magnetic materials or nanocrystalline alloys. The cores
additional insulated primary (HV) lead residing inside a separate external
and secondary winding reside inside an aluminium cast protective housing
insulator.
which is designed to safely lead the fault current to ground without danger of
an arc occurring within the external insulator. Insulator
As per request, the external insulation can be either porcelain or composite.
Paper-Oil Insulation
The porcelain insulators are made of highest quality C130 aluminous
The high voltage primary side is insulated from the low voltage secondary
porcelain, while the composite insulators are composed of a glass-fibre
side by means of oil impregnated paper of high dielectric strength.
reinforced resin tube and silicone rubber sheds.
The paper insulation is then dried in high vacuum and impregnated with
The insulator creepage distance is based on ambient air pollution and is to
high grade inhibited and degassed (moisture content of no more than 2 ppm)
be quoted in the inquiry.
mineral transformer oil. We guarantee the oil in our transformers not to
contain polychlorinated biphenyls and terphenyls (PCB & PCT).
The paper-oil insulation is closed in and hermetically sealed off from
ambient air by means of a stainless steel bellows. The stainless steel
bellows compensates the thermal oil expansion and thus also serves as an
expansion mechanism and an oil level indicator. Alternatively, the VKU type
transformers with lower oil quantity (lower voltage levels) have a gas cushion
system implemented.
All of the above ensure excellent and long lasting dielectric properties of the
transformers main insulation.
Terminals Housing
In case of current transformers (AGU), the primary terminals are made of The transformer housing consists of a base, insulator, head (AGU), tank (VKU)
aluminium or, alternatively, of galvanic corrosion protected (tin or silver and bellows cover.
plated) electrolytic copper. The terminal shape and type are both designed
During production, before the oil-filling process, a vacuum sealing test is
according to current ratings and applicable standards, unless specified
performed on every transformer, ensuring perfect hermetical sealing of the
otherwise in the inquiry.
enclosure.
In case of voltage transformers (VKU), the standard primary terminal material
The transformer base is made of high quality steel, which is hot dip galvanized
is tin plated brass and is M16x50 mm in size, unless otherwise defined in
and additionally painted for long-lasting corrosion resistance, or of cast
the inquiry.
aluminium. The IP 65 secondary terminal box is located on it, along with
Standard secondary terminals are M8 in size and are of the stainless steel various other accessories, such as name plate, oil sampling and filling valve,
threaded bolt type. Other terminal types, materials and dimensions are lifting lugs, earthing terminals and an optional oil overpressure indicator.
available on request.
The secondary terminals, along with protective devices and tariff terminal
sealing, reside in the secondary terminal box. Cable glands or plates provide
entry to the box and are designed in accordance with customers’ needs.

Dimensions
Type Maximum Total Terminal Total Oil Base Minimal
System Height Height Weight Weight Mounting Creepage
Voltage Distance
kV mm mm kg kg mm mm
AGU-24 24 1125 750 80 15 280x280 600
The given indicative values refer to our
AGU-36 36 1350 950 120 20 280x280 950 standard porcelain versions and vary
AGU-52 52 1800 1440 200 35 400x400 1300 depending on electrical, mechanical
VKU1-24;36 24;36 900 900 95 11 230x155 600;950 and environmental parameters speci-
fied in the customers’ inquiry.
VKU1-52 52 1375 1375 130 20 230x155 1300
The values are susceptible to change in
VKU-24;36 24;36 850 850 120 15 230x155 600;950
the course of technical developments.
VKU-52 52 1375 1375 240 25 400x400 1300

KON»AR - Instrument transformers Inc.


P.O. Box 202
HR-10002 Zagreb, Croatia
phone: +385 1 379 4112
fax: +385 1 379 4040
e mail: [email protected] www.koncar-mjt.hr