BF-XP190
Ultraslim 3.1 mm Bronchoscope for Diagnostics of the Thinnest Bronchi
8092
BF-XP190
Main Features
Ultraslim Videoscope
Newly developed CCD on the tip realizes drastically improved image quality
while maintaining an ultraslim diameter and a 1.2 mm instrument channel.
NBI (Narrow Band Imaging)
7733
The incorporated NBI mode, an optical image enhancement technology,
improves the visualization of vessels on the mucosal surface. BF-XP190
Rotation
Insertion Tube Rotation Function control ring
The insertion tube can be rotated left or right up to 120˚ by simply turning a ring
8078
on the control section of the scope. This supports easier operation and smoother 120° in
insertion with less operator fatigue. left/right
7738
direction
Wider Angulation Range
An upward angulation range of 210° supports smoother insertion into the
Conventional BF-XP190
upper-lobe bronchi and allows more of a bend in the scope when an EndoTherapy (180°) (210°)
device is inserted into the endoscope’s working channel.
8095
Waterproof One-touch Connector
A new connector design minimizes the effort required for setup prior to and in between
cases. In addition, it is fully submersible without a water-resistant cap and eliminates the
associated risk of an expensive repair due to accidental immersion.
Ergonomic Scope Cable Direction
The angle of direction of the universal cord has been improved so that the scope cable
7734
does not hang limp, even if the video system is located behind the bronchoscopist.
Specifications
Field of view 110°
Optical system Direction of view Forward viewing
Depth of field 2–50 mm
3.1 mm (tapered part of distal
Distal end outer diameter
tip 2.9 mm)
Up Light-guide lens
Instrument channel outlet
Distal end enlarged
8090
Right Left
Objective lens
Insertion tube
Down Bending section Angulation range
Up: 210°
Insertion tube outer diameter 2.8 mm
E0428822 · 1.000 · 10/16 · PR · HB
Down: 130°
Working length 600 mm
Compatible Video system center OLYMPUS CV-190
Insertion tube rotation EVIS EXERA system Xenon light source OLYMPUS CLV-190
Yes
function
Channel inner diameter 1.2 mm
Instrument Minimum visible distance 1.5 mm from the distal end
channel
Direction from which EndoTherapy accessories
enter and exit the endoscopic image
Specifications, design, and accessories are subject to change without any notice or obligation on the part of the manufacturer.