VZI06 Instructions 02C
VZI06 Instructions 02C
Incandescent Dimmer
Cat. No. VZIØ6-1L, 600W (Lighted)
120VAC, 60Hz
DI-000-VZI06-02C
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS: WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations. • Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).
• If you are unsure about any part of these instructions, consult a qualified electrician. • Total minimum load must exceed 40W.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer- • Dimmer may feel warm to the touch during normal operation.
operated appliance. • Recommended minimum wall box depth is 2-1/2”.
• Use with incandescent or 120V halogen fixtures only. • Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming. • Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will • Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
turn the light on at the brightness level selected at the dimmer.
Tools needed to install your Dimmer INSTALLING YOUR DIMMER Step 3 Preparing and connecting wires: Step 4a cont’d Step 4b cont’d
This dimmer can be wired using side wire terminal
Slotted/Phillips Screwdriver Electrical Tape Pliers NOTE: Use check boxes √ when Steps are completed. screws or through backwire openings. Choose
Pencil Cutters Ruler appropriate wire stripping specifications accordingly. Dimmer Coordinating Remote (no LEDs) Dimmer
Step 1 WARNING: To avoid fire, shock, or death; Bk hot (Black) Bk Bk
hot (Black)
Changing the color of your Dimmer: turn off power at circuit breaker or fuse and test Wh
Do not use for
that power is off before wiring! Black incandescent
If a color change kit is provided with your device and a color change 5/8”
applications.
Green Green
is desired, proceed with the following step. Otherwise, proceed to Cut
(1.6 cm) Strip Gage Ground Ground
Green
Ground
“Installing Dimmer by itself or with other devices” section. To change (if necessary) (measure bare wire RD
OFF ON yL/RD Load yL/RD yL/RD Line
color of your device proceed as follows:
OFF ON
here or use gage on Black RD RD
OFF ON OFF ON Line 120VAC, 60hz
back of the dimmer)
OFF ON OFF ON
120VAC, 60hz
OFF ON OFF ON Bl Load
Use Terminal for 3-Way or
More Applications Only.
White
OFF ON OFF ON For Single-Pole Applications,
OFF ON OFF ON Do Not Remove This Label.
White Neutral (White)