HYDRAULIC DESIGN JACK WELL CLIENT:- MPIDC

HYDRAULIC DESIGN OF JACKWELL WELL CUM PUMP HOUSE FOR BENSOLA PM MITRA PARK
A. DESIGN OF JACKWELL WELL CUM PUMP HOUSE

Sl. No. Particulars Value/Qty Unit

1 Daily Demand for design = 30.00 MLD As per ANIT

2 Operation time per day = 20.00 hrs


3
3 Design Discharge for Intake Well = 1500.00 m /hr
3
= 0.417 m /sec

4 Height of Intake well from HFL = 1.50 m

5 Detention time assumed = 12.0 min


3
6 Volume of Intake Well = 300.00 m

7 Average Water depth for Suction = 6.5 m


2
8 Area required = 46.15 m

Considering circular Intake Well - Dia


9 = 7.67 m
of Intake
say 8.00 m
Provide
Provided Size of the Intake Well = 8.00 m dia x 6.5 m LD
INTAKE DEPTH CALCULATION
Source Bed Level = 429.00 m
Depth of Slit Pocket = 1 m
Detention Time = 12.0 min
Capacity Required for Detention = 300.00 m3
Depth required for Detention = 6.5 m
Velocity Through Pump Inlet Bell = 1.5 m/s
No. of Pumps = 4.0
Dia of Pump Inlet Bell = 0.6 m
Froud No. = 0.621
Minimum Submergence = 1.4 m
Floor Clearance Depth = 0.2 m
Total Depth = 9.1 m
Lowest Level of Bowl or Entry Level of
429.0
Water = m
Required Well bottom for operation of
429.0
pump = m
Bottom of Intake Well = 428.0 m
Adopt Excavation Level of Intake = 427.5 m
Checking for Scouring, if any
Excavation Depth of Intake = 1.5 m
changes as per soil report

Pump House
Diameter of Pump House = 8.00 m
Height of Pump House = 7.00 m
Top of Bund Level = 456.40 m
Higest Flood Level = 453.00 m
Pump Floor Level = 454.50 m
Roof Level of Pump House = 461.50 m

Height of Jackwell from Bottom of


27.00 m
Jackwell to Floor Level =

Inlet Pipe are Provided at Three Level


1st Inlet Pipe level = 429.50 m
2nd Inlet Pipe Level = 432.50 m
3rd Inlet Pipe Level = 448.50 m