1. GENERAL
DSSD25/DTSD25 Electronical Three-phase Multi-function Energy Meter is a kind of new
watthour meter which product by advanced microelectronic, technigyes\computer techniqyes and
S.M.T.It is
elaborately desingned and manufactured by our company. It can directly and accurately measure
every active and reactive energy both import and export and can do with it by relevant demand
of
rate and demand,it also can display the Instantaneous voltage, current, active power, power
factors, apparent power, power frequency and so on. All performance guideline is accord with
IEC62053-
22 "Electricity metering equipment (a.c.) - Particular Requirements - Part 22: Static meters for
active energy (classes 0,2 S and 0,5 S)"、IEC 62053-21:2003"Electricity metering equipment
(a.c.) -
Particular requirements - Part 21: Static meters for active energy (classes 1 and 2)"、IEC 62053-
23:2003"Electricity metering equipment (a.c.) - Particular requirements - Part 23: Static meters
for
reactive energy (classes 2 and 3)"、“IEC 62052-11:2003Electricitymetering equipment (a.c.) -
General requirements , tests and testconditions-part 11:Metering equipment. DL/T 614
"Multifunction electricity meterring equipment(A.C.)",and the communication is accord with
DL/645 "Multi-function watt-hour meter communication protocol"、“MODBUS
RTUcommunication protocol”.
This series of manufactures have two RS485 interfaces with mutual independence and one
optical port,it can program or data reading through RS485 or optical port.It also can set time
consumption .
This energy meter also have the functions of centennial calendar clock,the record of
events, waking up and data reading during power break.Because of steady performance,good
precision,
comprehensive function , easy manipulation,and credible measure ,it be regarded as a ideal
calculatedly aphance.Basic functionA high - speed and high - precision AC voltage current
acquisition
module is embedded , the sampling precision is high , and the electric energy metering is
accurate in real time ;The time-sharing metering combines active power, positive and negative
active
electricity and demand, combined reactive power, four quadrant reactive power, and has 485
functions of communication and infrared communication.Excellent electromagnetic
compatibility,
Resist the interference of high pressure peak pulse, strong magnetic field, strong static electricity,
lightning surge, and have strong adaptive ability range of temperature;Three-phase power
supply
(i.e. line power supply mode),The electric energy meter can still work normally when any phase
or the two phase and four wire in the three-phase three wire is broken down.In the case of loss of
AC power, the meter can keep the data and maintain the clock chip.Low power
consumption;Sealing design,PVC waterproof and flame retardant material, wall hanging
structure, compact size, easy
to install.
2.1 Measurement function
1).Measure active energy import and export in four rates(the active energy’s measurement mode
can set)
2).Measure reactive energy import and export in four rates(the reactive energy’s measurement
mode can set)
3).Measure total active energy,total reactive energy,active energy in every phase for the both
the current and last month , reactive energy in every phase for the cunrrent month.
4).Measure reactive energy in four rates at four quadrants.
5).Mesure active maximum demand import and export,reactive maximum demand import and
export and the four quadrant”s reactive maximum demand with time stamp.
6). Record three months’ data for energy and demand;record tweleve months’ data for active
energy import and active maximum demand import.
2.2 Multi-rates function
1).Four rates,14 period, 8 day time table, 14 year time zone, 254 public holiday;
2)The meter has the function of programming and recording time table and settlement day.
3)2 sets of time zone tables and 2 sets of daily schedule;
4)The out-configure’s clock chip have functions of calendar,hour format and leapyear auto
switch.
2.3 Display function
1).LCD display,it can display clear at the temperature -30℃ to 55℃.
2)Data scroll display function(the number of the scroll display can’t exceed 96),the
scroll display code,the scroll-display sequence can be programed discretionarily
3).Data key display function(the number of the manual scroll display can’t exceed 96),
the key display code,the key display sequence can be programed discretionarily.
4).Using the remote infrared controller can check any data content.
5).The data content of LCD display have English and related symbols for hint.
2.4 Communication function
1).The meter have two RS485 interfaces and one optical port, PC or HHU can use this ports to
communicate with meter at the same time,and it will not interfere each other .When they
communicating;
the optical port is used for programmable and data reading.,it also be used for checking the
meter’s data as remote control.
2).The RS485 interfaces can insulate by electricity to the meter inside,and it is designed to avoid
the thunder’s attack.
3). The communicationg ‘s protocol is DL/T 645、MODBUS RTUcommunication protocol.
2.5 Output function
1)Has the function of pulse test port output, and has telecontrol pulse output for active energy
import and export, and telecontrol pulse output for reactive energy import and export.
2).Have multifunction signal outputs,such as 1HZ clock,the warning signal for overload and loss
of voltage, demand interval for meter’s test .
3).Have signal outputs for warning.
4)Remote output function (optional): it has the function of pulse test port output, and has positive
and reverse reactive power, far artery impulse output, forward and backward reactive power
remote artery impulse output function.
5)Analog output function (optional): 4-20mA analog output function..
2.6.The function of event record
1).Real time measurement of A, B, C three phase voltage, current, power and other effective
values and current frequency
2).It has the following functions: loss of voltage, phase interruption, loss of current, full
voltage loss, voltage reverse phase sequence, undervoltage, overvoltage, overcurrent,
interruption,
unbalanced current, overload, total power factor, stop call, programming, zero clearing and time
calibration.
2.7.The special function
1).Waking up and data reading during power break
2).Display the information for failure,the function of warning(the LED and display);
3).It has the functions of timing freezing, instantaneous freezing, convention freezing, daily
freezing and whole freezing.
4).Record the data of the electric meter before zero clearance.
5).Password locking function: after the password verification 3 errors, the liquid crystal will

show " ", at this time the meter will automatically lock up for 24 hours.
6)Has the auxiliary power supply function(optional).
7)Load curve recording function(optional)
Open cover recording function;
2.8.The analog output function (optional)
The instrument has analog output and output function (hardware and software support). The
output of the measurement is output in analog form. The analog output can be set to any one of
the 23 measuring quantities. The analog output is set as follows:

0 Closing the analog send out channel


1~2 23 measurements are corresponding to the
3 output of 4~20mA, respectively.(Note 1)
The total active power of two directions
respectively,
AO Converter
A phase active power, B phase active power,
SIx output
C phase active power, total reactive power,
24~
A reactive power, B reactive power, C phase
35
reactive power, total power factor,
A phase power factor, B phase power factor, C
phase power factor measurement,output
4~12~20mA (Note 2)
AO Variable 1~9 20mA output corresponding parameter values
Sx output 999
parameter
value
Note: 1. power address reference user manual
2. power measurement range is: -AOSx~0~AOSx; the power factor
measurement range is: -AOSx~1.0 x 1000~AOSx. For
example, AOSI is set to 24,
set the AOSx value is 1100, the total power of -1.1~0 corresponding to
the kW output is 4~12mA, the total power of 0~1.1 corresponding
to the kW output for 12~20 mA; the AOSI is set to 32, set the
AOSx value is 500, the total power factor corresponding to the
0.5C~1.0 output is 4~12mA,
the total power factor corresponding to the output 1.0~0.5L 12~20
mA.

Analog quantization output setting


The data of all analog quantum output sets are 2 bytes SX according to a certain formula, and the
range of the value is 1~9999 (the absolute value).

Range of
Project Formula Symbol Remarks
value
Unsign
Voltage SX = U/PT×10 1~9999 UA,UB,UC
ed
Unsign
Current SX = I/CT×100 1-9999 IA,IB,IC
ed
Unsign
Frequency SX = F×100 1-9999 FR
ed
Unsign PFA,PFB,PFC,
Power factor SX = PF×1000 1-9999
ed PFS
SX = Unsign
Active power 1-9999 PA,PB,PC,PS
P/PT/CT×1000 ed
Reactive SX = Unsign
1-9999 QA,QB,QC,QS
power Q/PT/CT×100 ed
Apparent SX = Unsign
1-9999 SA,SB,SC,SS
power S/PT/CT×1000 ed
Note: PT- voltage ratio CT- current ratio

Data transformation formula for analog quantum output and output

Analog converter output project


Project setting
4~20mA
A phase voltage
B phase voltage
C phase voltage
A phase current
B phase current
C phase current
Psum
Active power of A phase
Active power of B phase
Active power of C phase
Total reactive power
Reactive power of A phase
Reactive power of B phase
Reactive power of C phase
Total power factor
A phase power factor
B phase power factor
C phase power factor
Total view in power
A looked at each other in power
B looked at each other in power
C looked at each other in power
frequency
Double directional total active
power
Active power of two directional A
phase
Active power of two directional B
phase
Active power of two directional C
phase
Two directional total reactive power
Two directional A phase reactive
power
Two directional B phase reactive
power
Two directional C phase reactive
power
Two directional total power factor
Two directional A phase power
factor
Two directional B phase power
factor
Two directional C phase power
factor

Switch output / analog variable output project setting


3. Technical data
3.1 Specification and model(See Table 1)
Table 1

Class index Basic curre


Reference
Model Species Reacti nt
Active voltage
ve Ib
Three- 3×0.3(1.2)
DSSD2 0.2,0.5,0.5S, 3×110V
phase 1,2 A
5 1,2 3×100V
three-wire 3×1.5(6)A
3×0.3(1.2)
Three- 3×63.5/110V
DTSD2 0.2,0.5,0.5S, A
phase 1,2 3×57.7/100V
5 1,2 3×1.5(6)A
four-wire
3×220/380V 3×1.5(6)A

3.2 Battery working parameters


Clock accuracy:day error ≤0.5s(23℃)
Battery capacity :≥1200mAh
Data storage time after power cutting off:≥10 years (using new battery)

3.3 Electric parameters


Voltage of specified operating range:0.9Un~1.1Un
Voltage of limit operating range:0.8Un~1.15Un
Power consumption of voltage circuit :< 1.5W、6VA
Power consumption of current circuit(Ib<10A):< 0.2VA
Power consumption of current circuit(Ib≥10A):< 0.4VA
Scope of work provided for auxiliary power supply:0.8Umin~1.2Umax (100V~
240V,AC and DC adaptive)
Voltage of battery for data storing:3.6V(DC)
Voltage of battery for data reading after power outage:6.0V(DC)
Auxiliary power supply:Auxiliary power consumption:<10VA ;
Power consumption of voltage circuit :≤ 0.5 VA
3.4 Climatic condition
Normal working temperature:-25℃~+55℃
Limited range of temperature:-40℃~+70℃
temperature for storage and transport:-40℃~+70℃
Relative humidity:Annual mean ≤75%
For 30 days , these days being spread in a natural manner over one year:95%
Occasionally on other days:85%
3.5 Technical parameters
The number of tariff:4
The number of time zone:14
The range of measure:-799999.99 kWh~799999.99 kWh , -799999.99 kvarh~799999.99
kvarh
Class index:0.5
Display Type:LCD
Communication baud rate:
RS485①interface:1200bps~9600 bps(Default2400bps)
RS485②interface:1200bps~9600 bps(Default2400bps)
RS485②interface:1200bps~9600 bps(Default9600bps(MODBUS RTU))
Optical interface: 1200bps
Communication protocol:DL/T 645”Multifunction electricity meterring
equipment”“MODBUS RTUcommunication protocol”.(RS485②interface)
3.6 Mechanical Parameters
Outline dimension:295mm175mm82mm (With pothook)
Installation dimension: 245mm150mm
Weight: Approx 2.3kg

4. Meter installation and connection

4.1 The meter should be fixed on the place that indoors and should be ventilation and dry to
ensure that the installation is safe and reliable.If it is a dirty or possible damage place ,the meter
should be protectedinaabinet.

Fig. 1: Meter profile


4.2 At the top of the meter ,there is a hole that can be fixed by a screw(M410),at the below of the
meter ,there are two holes that can be fixed by two screws(PA410 or PA412).please use the sizes
as follows to drill the soleplate,and the meter’s base should be fixed in the place where is
hard ,fireproof and no-shake.
4.3 The meter shoule be wired correctly follow the diagram.Advise to use copper or copper
connectors as the lines to connect the terminal block.The screw in the terminal cover should be
tightened to avoid burnned that caused by the wire who are too thin or not chonnect well.
4.4 Terminal connection diagram
4.4.1 Multifunction terminal connection diagram (shown in Fig.2)
(For reference only,the fact is showed on the connection diagram of the cover negative)

Fig.2 Multifunction terminal connection diagram(Telecontrol output function)

Fig.3 Multifunction terminal connection diagram

Fig.4 Multifunction terminal connection diagram(1 way simulation + telecontrol output


function)

Fig.5 Multifunction terminal connection diagram(2 way simulation)


4.4.2 Power terminal connection diagram(shown in Fig.6)

3X220/380V Straight type(large current/medium current)Three-phase four-wire

3X220/380V ≤3 X1.5(6)A Three-phase four-wire

3X57.7/100V ≤3 X1.5(6)A Connection through the voltage and current transformer

3X100V (Straight type)Three-phase three-wire

3X100V Straight type(B phase display) Three-phase three-wire( B phase measurement)

3X100V ≤3 X1.5(6)A

3X100V ≤3 X1.5(6)A (B phase display)


Connection through the voltage and current transformer
Fig.6 Power terminal connection diagram

4.4.3 The schematic of active and reactive ‘s port for test output
The output of optocoupler in the meter (The duty cycle is 1:1 when the cycle less than
200ms)
4.4.4 The schematic of the 1Hz clock for test output
5. Panel and symbol

Symb
Explanations
ols
Units: kWh-active energy kW—active demand kVA-
apparent power kvarh-reactive energy kvar-reactive
demand

Proguamming is available

Demand resetting locked symbol, it will appear after you have


finished demand resetting successfully, and it will persist for
about 5 minutes, which means
demand resetting is not allowed during this period
Battery state,it will flash when 3.6V-battery voltage is not
sufficient

LCD alarm indication

Communication symbol (flash during communication)


Stand for A current,B current ,C current;
disappear while current break .
Stand for A voltage, B voltage, C voltage;
flash while under voltage or over voltage,disappear while
voltage break

Current energy and energy direction

T1,T2,T3,T4 represent Tariff 1,Tariff 2,Tariff 3 and


Tariff 4

Current data

last month,the month before last

Display No.

Display data

Explanation of LCD symbols

6. Transport and storage


The meter shall not be subjected to severe impact during transport and un-packing, and
be transported and stored according to requirements of national standards GB/T15464 “General
technical requirements for packaging of instruments and apparatus”. Keep the meter on the
shelves with its original package during storage, the stacking height shall not be higher than five
layers. The storing place should be keep clean and the ambient temperature shall be within the
range of-25℃~+70℃, with relative humidity less than 85%, and no corrosive gasses in the
atmosphere.
7. Warranty
Only in the conditions that the user fully follows the operating instructions and keeps lead seal
intact, the manufacturer will provide repair or replacement free of charge within 18 months after
the date of shipment for the meter that has nonconformance to the technical requirements.
8. Appendix Instruction of remote infrared controller
The remote infrared controller is designed to help users to see all the data and parameter,the
basic function of it is to check the content of Items,to reading the datas,and to make the meter
scroll display.
The remote infrared controller’s form is as follow。
Figure and function keys:
Figure keys:【0~9】keys
【0】 key:display all the content of the LCD。
【1~9】keys:push 0~9 key to display the corresponding
content of each item.
For example, to display the content of Item 1.03, push the key 【1】, LCD will display 01.00
item, then push【↓】 key three times and it will display the content of Item 1.03
Function keys:
【关闭】key:when LCD is displaying,push 【关闭】 key for one time,all the items on
LCD will disappear, and it will switch into auto scroll display automatically after 8 seconds.
【↑】【↓】key:Push 【↑】key to display the content of the previous item,
Push 【↓】key to display the content of the next item.
【1-】key:push this key and 0~9 key subsequently to display the content of Items 10~19 in

the meter.
【2-】key:push this key and 0~9 key subsequently to display the content of Items 20~29 in
the meter.
【3-】key:push this key and 0~9 key subsequently to display the content of Items 30~39 in
the meter.
【4-】key:push this key and 0~9 key subsequently to display the content of Items 40~49 in
the meter.
【5-】key:push this key and 0~9 key subsequently to display the content of Items 50~59 in
the meter.
【6-】key:push this key and 0~9 key subsequently to display the content of Items 60~69 in
the meter.
【7-】key:push this key and 0~9 key subsequently to display the content of Items 70~79 in
the meter.

【8-】key:push this key and 0~9 key subsequently to display the content of Items 80~89 in
the meter.
【9-】key:push this key and 0~9 key subsequently to display the content of Items 90~99 in
the meter.
For example, to display the content of 88.03, push【8-】key first, then push figure key【3】,
LCD will display 83.00, push↓key repeatedly till 88.03 is displayed.
【键显】key:Manual scroll display of preset content can be achieved by pushing this key.
【循显】key: key: scroll display of preset content can be achieved by pushing this key.
【查询】key: This key is special to display current date and time. When pushing this key,
Energy meter will display current date and time in scroll.

Our company has the right to upgrade the product and update this manual, if there’s
something different in the content, we would like to have your understanding!