ExamVue Duo Software User Manual For VET r5
ExamVue Duo Software User Manual For VET r5
User Manual
Product: ExamVue Duo
Document Number JTD-ExamVueDuo-DHF11 (Rev.1)
S
i
g
n
1 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Revision History
2 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Contents
2. Introduction .................................................................................................. 6
6.3 Tools.................................................................................................................. 15
3 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9.2 Viewer................................................................................................................ 76
Appendix 6 – How to use the demo image in the ExamVue Duo? ............ 109
4 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
1.1 Symbols
Symbols Descriptions
5 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
2. Introduction
ExamVue Duo is a software for the acquisition, processing, storage and viewing of digital x-
ray images and indicated for use in general radiography, specialist radiology including podiatry,
orthopedic, and other specialties, and in mobile applications. However, ExamVue Duo is not
intended for use in mammography.
3. Hardware Requirement
- PC Computer
1st Ethernet
Intel Integrated 1Gbps
Network Adapter
2nd Ethernet Intel 1Gbps Ethernet I210-T1 Server Adapter or USB 3.0 1Gbps
Network Adapter adapter
6 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Laptop Computer
1st Ethernet
Intel Integrated 1Gbps
Network Adapter
Wi-Fi Network Wireless card with AC connection up to 867 Mbps for maximum
Integrated Adapter DR connection
USB 3.0 Wi-Fi USB wireless card with AC connection up to 867 Mbps for
Network Adapter maximum internet connection
7 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
4. Software Configuration
The program includes five windows, and the entire interface is designed for the touch screen
operation.
8 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
All patient information stored in the database are displayed according to the search option.
9 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
10 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
5. Log-In Window
Once the program has been started you will be asked to log in. Depending on the login level
some features will be limited. Please just confirm the boxes the registered ID and PWD.
- Admin Privileges: Allow to access the Settings Window and delete images.
- Technologist Privileges: User operator but no access to Settings Window and can’t
delete images.
- Login: Check the ID and PWD. if it’s available and entry to the Worklist Window.
11 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
6. Worklist Window
Through DICOM Worklist Server (MWL), you can take the patient information, integrated with
hospital system, or input the patient information manually.
⚫ To use MWL Server, you must register the MWL Server’s information in the
Settings Window.
12 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⑫ Queue: Display the data status of the PACS and DICOM Print
⚫ You can set up a remote application (ex. TeamViewer) path from the
Settings window.
13 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- ALL
Expansion Search
Clicking the button will rise to the expanded search criteria and
search for some studies with details.
14 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
6.3 Tools
Icon Name Description
Import Import the patient list using the CSV file format
15 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
16 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ If clicked the Search button with some name or ID in the ‘FIRST NAME’ or
‘PATIENT ID’, all patient information related will be displayed in the pop-up
window and you can select one. Then it will be filled out automatically in
the Patient Information Window.
17 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
6.5.1 Pictogram
The illustration is divided into different sections (organ groups).
- HEAD
- TORSO
- PELVIS
By clicking on an organ group, e.g. skull, all standard projections of the selected organ
will be shown. Click on the examination to be performed to create a corresponding list
entry in the right Study List.
⚫ You can make new Anatomy and Projection in the separated Management
software. Please contact to the administrator if needed.
18 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ You can make new Preset list in the separated Management software.
19 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
20 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
7. Exam Window
User can acquire the X-ray image from the detector.
The right side is the tools panel, and the left side of the screen is the study list. If the generator
is connected the generator panel will be shown as shown the below figure.
21 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Search patients that already registered to the database with search option.
22 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
V Flip
Flip an image Vertically / Horizontally
/ H Flip
23 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Window Level
Reset the window level
Reset
Window Level
Change the window level automatically
Auto
24 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Rectangle /
Ellipse Crop an image of interest in the image
Cropping
Delete
Delete selected annotation information
Annotation
Pencil
Draw the freely line in the image
(Free draw)
25 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Patient
Information Shows or hides the patient’s information
ON / OFF
Vertical /
Displays the angle and Vertical / Horizontal
Horizontal
length of two points
Offset
26 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Length
Calibrate the length
Calibration
Paper Print Print out the viewing image to the paper print
27 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
28 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
29 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
[Fit Image]
⚫ Real Size
30 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Full Screen
[Full Screen]
⚫ CCW90 / CW90
[CCW90] [CW90]
31 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Free Rotation
[Free Rotation]
⚫ V / H Flip
V Flip
Flip an image Vertically / Horizontally
/ H Flip
[V Flip] [H Flip]
32 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Panning
[Before] [After]
1) Press and hold the left mouse button while dragging the image to the desired position.
⚫ Magnifying
[Magnifying]
⚫ To set up ROI Window Size, you can set the configuration in the Settings
Window.
33 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ ROI Zoom
⚫ Invert
34 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Window Level
[Window Level]
35 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Line Profile
⚫ Histogram
[Result Display]
36 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
[Text Image]
37 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ R / L Marker
[R Marker] [L Marker]
⚫ It’s the same way to resize the ‘R’, ‘L’ marker, User marker and Text size.
38 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ User Marker
[Mark Image]
1) Click Mark button.
2) Enter the user maker and click Add button and then the use marker will be registered
and shown in the list.
3) Select the user marker.
4) Click Okay button.
⚫ Ruler
[Ruler]
39 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Arrow
[Arrow]
⚫ Angle
[Angle]
⚫ When you complete drawing an angle, the value of the angle will be
calculated and displayed automatically.
40 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Rectangle /
Ellipse Crop an image of interest in the image
Cropping
41 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Cobb Angel
[Cobb Angle]
⚫ Line
[Line]
42 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Center Point
[Center Point]
⚫ Expand Line
[Expand Line]
43 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Pencil
Draw the freely line in the image
(Free draw)
[Pencil]
[Show] [Hide]
44 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Patient
Information Shows or hides the patient’s information
ON / OFF
[ON] [OFF]
⚫ Dot
[Dot Image]
45 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Black Rectangle
⚫ Axial Line
[Axial Line]
46 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Vertical /
Displays the angle and Vertical / Horizontal
Horizontal
length of two points
Offset
[Exposure Parameter]
47 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Length Calibration
Length
Calibrate the length
Calibration
1) Enter the actual length (mm) on Real and then click ok.
⚫ E-mail Send
[E-mail Send]
48 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Before working it, you must configure the E-mail Sever settings in the
Settings Window. (See Appendix for descriptions)
⚫ DICOM Send
[DICOM Send]
⚫ Before working it, you must configure the PACS Sever settings in the
Settings Window.
49 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ DICOM Print
[DICOM Print]
50 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ File Import
[File Import]
⚫ If you click the ‘New Patient’ option during importing, the new ID and
Name including in the DICOM tag will be created automatically.
51 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ File Export
[Export Window]
Name Description
Device Select the export device with Local Disk, USB or CD/DVD
Set the image path for the image export. It allows only USB and
Path
Local Disk
Image Type Select the image type in the BMP, JPG, RAW and DICOM
52 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Report
Make the report of the selected image using the report
Report form and export to the report PDF, E-mail or Paper print
device
[Report Window]
Name Description
Patient Information Display the information of the selected study
Information /
Include patient Information / Annotations
Annotation
53 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Dual Screen
[Dual Screen]
⚫ QC Pattern
54 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
8. StudyList Window
StudyList Window allows you to retrieve past studies from the database and shows in the list.
Name Description
Patient ID Input a patient ID of study to search
55 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Rejected Image
E-mail
Send the selected image to E-mail
Send
DICOM
Send the selected image to DICOM
Send
56 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Expand /
Expand / Reduce the study list
Reduce
57 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Merge
[Merge Window]
1) The Source contains the selection from the Study list in the Study Window.
58 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Import
[Import Window]
59 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Export
Convert and export the selected images with various
Export formats to the local drive, external USB or CD/DVD
equipment
[Export Window]
Name Description
Device Select the export device with Local Disk, USB or CD/DVD
Set the image path for the image export. It allows only USB and
Path
Local Disk
Image Type Select the image type in the BMP, JPG, RAW and DICOM
60 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Report
Make the report of the selected image using the report
Report form and export to the report PDF, E-mail or Paper print
device
[Report Window]
Name Description
Patient Information Display the information of the selected study
Information /
Include patient Information / Annotations
Annotation
61 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Compare
[Compare Window]
Name Description
ADD Adds the selected image from the Thumbnail List
[Image Viewer]
62 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ DICOM Print
Name Description
Print Name Name of DICOM Print Server to be used
Medium Type Type of medium on which the print job will be printed
⚫ Before working it, you must configure the DICOM Print settings in the Settings
Window.
63 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ PACS
⚫ Before working it, you must configure the PACS Sever settings in the Settings
Window.
64 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Restore
[Restore Window]
65 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9. Settings Window
Administrator privileges are required to access the Settings window. If you cannot find the
Settings Window menu in the top main menu, contact your administrator.
You can also save and apply the changed settings in the Settings window by clicking the Apply
button and restarting the software.
9.1 General
9.1.1 System
66 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Name Description
Software Information Display Software Name
Auto Log off Time Select the Auto log off time
67 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9.1.2 Institution
Name Description
Name Institution name
Logo Set the logo and it will be displayed in the Report form
68 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9.1.3 Account
Configures the account of the ExamVue Duo users and currently registered information
is available on the list.
Name Description
ID ID information
69 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9.1.4 Display
Allow information to be displayed on the upper left, lower left, upper right, and right sides
of the image, and you can select Skin.
Name Description
ALL Disable Hide all information when displayed an image in the viewer
Display Information
Choosing the font size for information display
Font Size
Skin Color Choose one of skins in Gray Dark, Navy and White
70 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9.1.5 Backup
Backup and restore the database file.
⚫ Backup Database
Name Description
71 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Local Storage
User can save the JPG image automatically in the specified storage path during acquiring
the image from the detector. And, during saving the image, user can set the options like
the ‘Burn Annotation’ and ‘Burn patient Information’.
Name Description
Save path Path where images acquired from the detector are stored
Burn Patient
Save the patient information in the JPG image
Information
72 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9.1.6 Options
⚫ E-mail
Name Description
73 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ General
Name Description
Enable / Disable the virtual keyboard
If a user click the virtual icon, the virtual key board will be
displayed as below
On-Screen keyboard
→
Show or Hide the Exam Positioning guide
Suggested Technique When moving to the Exam window, the examination guide will
be displayed according to the option
Show or Hide the Reject window.
Reject Password When you attempt to run the reject function, a pop-up window
will pop up and prompt you to enter your password
Close Study to Change Select the screen that changes when you close the Study
the Window (WorkList, StudyList)
74 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Examination
Name Description
Annotation Auto Save Save Annotation automatically
Auto Cropping Enable the auto cropping function while Exam mode
Grid Line Suppression It can remove the gird line in the image
75 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Auto Delete
Name Description
You can automatically delete data. Choose one of two options
- Delete by Period
9.2 Viewer
Name Description
Up Up to the selected header column
76 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9.2.2 Annotation
User can set Viewer option and Font option.
⚫ Viewer Option
Name Description
Magnify Zoom Set the Magnify zoom ratio
⚫ Font Option
User can set the color in the annotation features.
77 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
9.3 Network
9.3.1 Configuration
Configures the network information.
Name Description
Enter name of the local pc which will be displayed on the
AE Title
Network
78 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ MWL Option
Name Description
MWL Server (Default) Enable or Disable the MWL feature
Query Modify Type Select the modality type of the imaging equipment
Select the tag to match the code matching at the below table
- Requested Procedure ID
Procedure Tag
- Requested Procedure Description
Selection
- Scheduled Procedure Step Description
79 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ MWL Server
Name Description
AE Title AE Title for MWL
IP IP for MWL
9.3.3 PACS
Configures the network information of the PACS Server, which stores the images files.
80 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ PACS Setting
Name Description
Enable Auto Send when a When you close an exam study, DICOM images are
Closing Study automatically sent
⚫ PACS Server
Register PACS Server Information and select one or more PACS Server in the list.
Name Description
AE Title AE Title for PACS
IP IP for PACS
81 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Printer Option
Name Description
Size Choose the film size you typically use
Medium type Type of medium on which the print job will be printed
82 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
⚫ Layout
Allow the location to show Patient Information in the image.
9.4 Utility
Name Description
Period Today, 1 Week, 1 Month, ALL, From To
Print out the result as the Report format and can save the
Export
PDF format
83 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
84 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
For the IP number, please refer to the detector user guide manual by the
manufacturer
85 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
86 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
87 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
[Error message]
- Check the AE Title, IP address and port number in the Settings Window. Please
move to the MWL menu and check all settings.
88 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
So, user can control the image according to the mouse settings.
◼ Left button
◼ Right button
◼ Wheel button
◼ Right button and drag
If you need to adjust the window level, please press and hold the mouse button user set
89 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Measure an angle between lines, each line drawn along the center of the 4 points specified.
Axis Angle measurement can be used to identify an angle of crossed line.
1) Mark a first point on an arbitrary location of the target of interest.
2) Mark a second point on an arbitrary location of the target of interest.
3) Mark a third point on an arbitrary location of the target of interest.
4) Mark a fourth point on an arbitrary location of the target of interest forming an axis line.
5) Mark a first point on an arbitrary location of the target of interest.
6) Mark a second point on an arbitrary location of the target of interest.
7) Mark a third point on an arbitrary location of the target of interest forming an axis line.
90 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Clock face
Superimpose a clock faced feature on the image. Clock Face measurement can be used
to diagnose an anatomical positioning of a canine heart.
1) Mark a point on the top margin of the canine heart.
2) Mark a point on the center of the canine heart forming a clock face.
<Default>
<Lat View>
91 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Cross angle
Measure an angle between lines crossed. Each line is drawn along the 2 points specified.
Cross Angle measurement can be used to identify an angle of crossed lines.
1) Mark a first point on an arbitrary location on the target of interest.
2) Mark a second point on an arbitrary location on the target of interest forming a line.
3) Mark a first point on an arbitrary location on the target of interest.
4) Mark a second point on an arbitrary location on the target of interest forming a cross
line.
92 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Liver size
Liver size is one of the important standards used to establish differential diagnoses for
dogs and cats with suspected hepatic diseases. (i.e., hepatomegaly for hepatic congestion,
inflam-matory and infiltrative disease, hepatic neoplasia or micro-hepatia for hepatic
cirrhosis or portosystemic shunt)
1) Mark a point on the left margin of T11 of the vertebral at the level of the center of the
endplate.
2) Mark a point on the right margin of T11 of the vertebral at the level of the center of the
endplate.
3) Mark a point on the most cranial point of the diaphragm.
4) Mark a point on the caudal vena cava to the apex of the caudal hepatic border.
93 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Middle angle
Measure an angle between a line specified and a line formed from a center point of a line
specific to an arbitrary point. Middle Angle measurement can be used to identify an angle
of interest.
1) Mark a first point on an arbitrary location of the target of interest.
2) Mark a second point on an arbitrary location of the target of interest forming a line.
3) Mark a third point on an arbitrary location of the target of interest drawn from the pivot
point forming an angle.
94 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Norberg angle
Norberg Angle is used in assessing hip laxity and in detecting hip dysplasia.
(The default Norberg Angle is 105 degrees)
1) Mark a first point on the outline of the femoral head.
2) Mark a second point on the center of the femoral head forming a circle.
3) Mark a point forming a line connecting the center of the femoral head to the cranial
rim of acetabulum.
4) Mark a first point on the outline of the femoral head.
5) Mark a second point on the center of the femoral head forming a circle.
6) Mark a point forming a line connecting the center of the femoral head to the cranial
rim of acetabulum.
95 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Percent coverage
Measure the percent of femoral head covered by the size of cranial rim of acetabulum.
PC is an indication of the support provided by the acetabulum to oppose the force
transmitted from the femur.
1) Mark a first point on the medial surface of the femoral head.
2) Mark a second point on the center of the femoral head forming a circle.
3) Mark a third point on the cranial acetabular rim.
96 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Spine label
The spine labeling tool is to name the vertebrae. Starting at the top of the C-spine to
bottom of CY-Spine (Tail)
1) Spine Label window will be displayed. Select the start label.
2) Mark the spine label at the location of the target of interest. (Repeat)
3) Mouse R-click will finish the Spine labeling.
97 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
The TPA is characterized as the angle between a line tangential to the central articular
surface or intersecting the cranial and caudal landmarks of the medial tibial plateau and a
line perpendicular to the mechanical long axis of the tibia, which is measured from a
standard lateral radiographic image of the tibia.
1) Mark a point on the center of the talus.
2) Mark a point on the center of the intercondylar eminences.
3) Mark a point on the cranial top of the tibial plateau.
4) Mark a point on the cranial inside of the tibial plateau.
98 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
- Vertical Discrepancy
Measure the length discrepancy from the points specified. Vertical Discrepancy
measurement can be used to identify a vertical tilt between two points.
1) Mark a first point on an arbitrary location of the target of interest.
2) Mark a second point on an arbitrary location of the target of interest forming a tilting
line.
99 / 114 Page
JPI Healthcare Co., Ltd. ExamVue Duo User Manual
608-ho,28, Digital-ro 33gil, Issued Date: 2021.10.06
Guro-gu, Seoul, Revision: 3
08377, Republic of Korea
Measure Vertebral Heart Score and the length of average vertebrae from T4 to T8. VHS
measurement can be used to diagnose canine cardiomegaly and to describe a
progressive change in heart size.
1) Click on Caranial Edge of T4.
2) Click on Caranial Edge of T5.
3) Click on Caranial Edge of T6.
4) Click on Caranial Edge of T7. (Mouse R-click to go for long axis directly)
5) Click on Caranial Edge of T8. (Mouse R-click to go for long axis directly)
6) Click on Caranial Edge of T9. (Mouse R-click to go for long axis directly)
7) Click on Caranial Edge of T10.
8) Mark a point on the top margin of the canine heart.
9) Mark a point on the bottom margin of the canine heart forming a long axis.
10) Mark a point on the left margin of the canine heart.
11) Mark a point on the right margin of the canine heart forming a short axis.
Measure Vertebral Left Atrial Score. VLAS is a highly re-producible measurement that has
a moderate positive correlation with echocardiographic measurements of LA size. Thus,
the VLAS provide a quantitative measurement of LA size that can be determine from right
or lateral thoracic radiographs.
1) Mark the first point at the center of the most ventral aspect of the carina (bifurcation of
the left and right mainstem bronchi).
2) Mark the second point at the most caudal aspect of the left atrium where it inter-sects
with the dorsal border of the caudal vena cava.
3) Mark the third point at the cranial edge of T4.
4) Mark the fourth point at the parallel to the vertebral canal.
5) Please Enter VLAS(Vertebral Left Atrial Score)
Measure the joint angle and lateromedial deviation on the DP View. Joint angle and
Lateromedial deviation is important factors which determine forces affecting tendons and
ligaments.
1) Mark a point on the center margin of the fetlock bone P1.
2) Mark a point on the center margin of the pastern bone P2.
3) Mark a point on the center margin of the coffin bone P3.
4) Mark a point on the top left margin of the coffin bone P3.
5) Mark a point on the top right margin of the coffin bone P3.
6) Mark a point on the left margin of the ground surface.
7) Mark a point on the right margin of the ground surface.
- Lateral hoof
Measure the hoof wall angle, P3 angle and so forth on the Lateral View.
(Dorsal hoof wall angle, Parietal surface angle, Heel angle, P3 angle, Dorsal hoof wall
thickness, Sole depth)
1) Mark a point on the top margin of the hoof wall.
2) Mark a point on the bottom left corner margine of the hoof wall.
3) Mark a point on the bottom margine of the heel.
4) Mark a point on the top margine of the heel.
5) Mark a point on the top margin of the coffin bone P3.
6) Mark a point on the bottom left corner margine of the coffin bone P3.
Measure the HPA from straight line running from the center of the fetlock, through the
pastern, continuing straight from the coronet to the ground surface.
1) Mark the first point at the left side of the fetlock.
2) Mark the second point at the right side of the fetlock.
3) Mark the third point at the left side of the pastern.
4) Mark the fourth point at the right side of the pastern.
5) Mark the third point on a hoof wall.
- Sinkage distance
Measure the length discrepancy from the points specified. Sinkage Distance
measurement can be used to identify a vertical tilt between Coronary band and Extensor
process.
1) Mark a first point on a Coronary band.
2) Mark a second point on a Extensor process.
2. Input the ID and PWD to log into the main program and click “Login” button
[Log-In Window]
[Main Window]
The popup below appears because the license has not been issued yet
9. If the license file is NOT activated like 8) message above, please copy the
“License.dat” file and send to JPI Healthcare’s administrator
10. Get the issued "License.dat" file from JPI Healthcare and overwrite the file into the
"C:\ExamVue Duo" folder
If you run ExamVue Duo and the login window appears as below, the license has
been successfully applied
[Log-in Window]
⚫ Please notice that the period to use the demo version is limited for 15 days.
⚫ If you need to expand the demo version, please contact to JPI Healthcare’s
administrator
7. Open the created INI file and set the values according to the added demo image
9. Click the browser button in ‘Image Processing Parameter’ and set the parameter file
If processed DICOM image is used, you don’t need to set the parameter file
User can send the acquired image as JPEG format using the feature of E-mail in the
software. However, please make sure to remember that User must set up an some settings
in the E-mail server menu in the advance like the below direction.
1. Server Setting
1) Click Server Settings button
2) Enter or select the server information of the Email you’re using in the menu
⚫ In the case of Google, mail delivery may fail due to security concerns. To resolve this, try
the following methods.
② If you can’t send mail again despite the above way, try the following methods.
④ Click “Account”(②)
⑤ Click “Security”(③)
2. To address
1) Select one of the email addresses entered in fig (③), Multiple choice available.
2) Users can directly input it. Email addresses are separated using “;”
Ex) [email protected]; [email protected]
3. File attachment
1) The file selected by the user is automatically attached and shown. In addition, the
user can attach the file using the file explorer.
2) File can be attached using “drag and drop” and buttons.
3) You can delete unwanted files from the text box, file names are separated using “;”
Ex) Test1.jpg; Test2.jpg; Test3.jpg
4. Send E-mail
1) Click the button fig (①)