ACTC3R2
ACTC3R2
ORDERING INFORMATION
ACTC
Contact arrangement/Operation function*
1: 1 Form A/Standard type
2: 1 Form C/Standard type
3: Double make contact 2 Form A/Standard type
6: Double make contact 2 Form A/2 coil latching type
Heat resistance/Protective construction
Nil: Standard type/Sealed type
H: High heat-resistant type/Sealed type
R: Pin in Paste type/Flux tight type
Coil resistance
1: 110Ω
2: 160Ω
3: 225Ω
6: 75Ω
TYPES
Part No.
Contact arrangement/Operation
Nominal coil voltage Coil resistance Heat resistance
function
Standard type High heat-resistant type Pin in Paste type
110 ACTC11 ACTC1H1 ACTC1R1
1 Form A/Standard type 160 ACTC12 ACTC1H2 ACTC1R2
225 ACTC13 ACTC1H3 ACTC1R3
110 ACTC21 ACTC2H1 ACTC2R1
1 Form C/Standard type 160 ACTC22 ACTC2H2 ACTC2R2
12V DC
225 ACTC23 ACTC2H3 ACTC2R3
Double make contact 2 Form A/ 110 ACTC31 ACTC3H1 ACTC3R1
Standard type 160 ACTC32 ACTC3H2 ACTC3R2
Double make contact 2 Form A/
75 ACTC66 ACTC6H6 ACTC6R6
2 coil latching type
Standard packing; Carton (tube): 40 pcs.; Case: 800 pcs.
ds_61282_83_en_tc: 060313J 1
TC (ACTC)
RATING
1. Coil data
1) Standard type
Nominal operating Nominal operating
Nominal coil Pick-up voltage Drop-out voltage Coil resistance
current power Usable voltage range
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F)
[10%] (at 20C 68F) (at 20C 68F)
Max. 6.5V DC Min. 0.5V DC
109 mA 110 1,309 mW
(Initial) (Initial)
Max. 7.0V DC Min. 0.5V DC
12V DC 75 mA 160 900 mW 10 to 16V DC
(Initial) (Initial)
Max. 7.5V DC Min. 0.5V DC
53.3 mA 225 640 mW
(Initial) (Initial)
Note: Other pick-up voltage types are also available. Please contact us for details.
2. Specifications
Characteristics Item Specifications
Arrangement 1 Form A, 1 Form C, Double make contact 2 Form A
Contact Contact resistance (Initial) N.O.: Typ3m, N.C.: Typ4m (By voltage drop 6V DC 1A)
Contact material Ag alloy (Cadmium free)
Nominal switching capacity (resistive load) N.O.: 30A 14V DC, N.C.: 15A 14V DC
Max. carrying current (12V DC initial)*3 35A for 1 hour (at 20C 68F)
1,309 mW (Pick-up voltage 6.5V DC type)
Rating 900 mW (Pick-up voltage 7.0V DC type)
Nominal operating power
640 mW (Pick-up voltage 7.5V DC type)
1,920 mW (2 coil latching type)
Min. switching capacity (resistive load)*1 1A 14V DC
Insulation resistance (Initial) Min. 100 M (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
Breakdown voltage Between open contacts 500 Vrms for 1 min. (Detection current: 10mA)
Electrical (Initial) Between contacts and coil 500 Vrms for 1 min. (Detection current: 10mA)
characteristics
Operate time [Set time] (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)
Release time [Reset time] (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial) (without protective element)
Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s)
Shock resistance
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
Mechanical
characteristics Functional 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10s)
Vibration resistance 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G},
Destructive
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 cpm)
Mechanical
Min. 106 (at 120 cpm) (2 coil latching type)
<Resistive load>
Min. 105 (at nominal switching capacity, operating frequency: 1s ON, 9s OFF)
Expected life
<Motor load>
Electrical
Min. 105 (30 A 14V DC at motor lock condition), operating frequency: 0.5s ON, 9.5s OFF
<Lamp load> *4
Min. 2 105 (at 84 A (inrush), 12A (steady), 14 V DC), Operating frequency: 1s ON, 14s OFF
Standard type Ambient temperature: –40C to +85C –40F to +185F,
Humidity: 5% R.H. to 85% R.H.
Conditions Conditions for operation, transport and storage* 2 High heat-resistant/Pin in Paste type Ambient temperature: –40C to +110C –40F to +230F,
Humidity: 2% R.H. to 85% R.H.
(Not freezing and condensing at low temperature)
Mass Approx. 10 g .35 oz
Notes:
*1.This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2.The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F).
*3.Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
*4.When using with an electric discharge lamp load or any other lamp load, or a capacitor load, connect COM to the “+ (plus)” side.
2 ds_61282_83_en_tc: 060313J
TC (ACTC)
REFERENCE DATA
1.-(1) Coil temperature rise (at room 1.-(2) Coil temperature rise (at 85C 185F) 2. Ambient temperature and operating voltage
temperature) Sample: ACTC12, 3pcs. range
Sample: ACTC12, 3pcs. Contact carrying current: 10A, 20A Sample: ACTC12
Contact carrying current: 10A, 20A, 30A Ambient temperature: 85C 185F
Ambient temperature: Room temperature
180 180 20
Temperature rise, °C
30A
140 140
15
120 120
100 100
20A
20A 10
80 80
10A
60 60 10A
5
40 40
Pick-up voltage (Cold start)
20 20
0 0 0
10 12 14 16 18 10 12 14 16 18 -40 -20 0 20 40 60 80 100 120
Coil applied voltage, V Coil applied voltage, V Ambient temperature, °C
3. Distribution of pick-up and drop-out voltage 4. Distribution of operate and release time
Sample: ACTC12, 40pcs. Sample: ACTC12, 40pcs.
* Without diode
40 40
Pick-up voltage Operate time
Drop-out voltage Release time
30 30
Quantity, n
Quantity, n
20 20
10 10
0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Voltage, V Time, ms
5.-(1) Electrical life test (Motor lock) Change of pick-up and drop-out voltage Change of contact resistance
Sample: ACTC12, 6pcs.
Load: 30A 14V DC 8 30
Contact welding: 0 time N.O. side
Pick-up and drop-out voltage, V
25
Ambient temperature: Room temperature 6
Circuit: Pick-up voltage 20
5 Max.
x
4 Min. 15
14V DC 3
10
M
2
Max. Max.
x 5 x
1 Min.
Min.
Drop-out voltage
0 0
0 5 10 0 5 10
No. of operations, × 10 4
No. of operations, × 104
5.-(2) Electrical life test (Lamp load) Change of pick-up and drop-out voltage Change of contact resistance
Sample: ACTC12, 6pcs.
Load: inrush: 84A/steady: 12A 14V DC 8 30
Contact welding: 0 time N.O. side
Pick-up and drop-out voltage, V
25
Circuit: 6
Pick-up voltage 20
5 Max.
x
4 Min. 15
14V DC 60W 60W
3
10
2 Max.
Max. x
5 Min.
1 x
Min.
Drop-out voltage
0 0
0 5 10 0 5 10
No. of operations, × 104 No. of operations, × 104
ds_61282_83_en_tc: 060313J 3
TC (ACTC)
DIMENSIONS (mm inch)
1 Form A type/Standard type External dimensions PC board pattern (Bottom view)
17.8 13
.701 .512
7 9.6
.276 .378
Max. 1.0
Max. .039 16 5×1.6 dia.
.630 5×.063 dia. 5 10.8
0.5
.020 A .197 .425
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
4 ds_61282_83_en_tc: 060313J
TC (ACTC)
Double make contact 2 Form A type/2 coil latching type
External dimensions PC board pattern (Bottom view)
17.8 13 3×1.1 dia.
.701 .512 3×.043 dia.
Max. 1.0 7 8
Max. .039 16 .276 .315
.630
0.5
.020 A 4×1.6 dia.
4×.063 dia. 5 10.8
3.5 .197 .425
.138
0.6
.024
0.6
.024
0.4
.016 1.2 0.4 Tolerance: 0.1 .004
.047 .016
+
RESET SET
NO COM
5 10.8 (0.9)
–
.197 .425 (.035)
NO COM
+
Dimension: Tolerance
COIL
Less than 1mm .039inch: 0.1 .004
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008 * The lamp control type has polarized contacts.
Min. 3mm .118 inch: 0.3 .012 Connect COM to the “+ (plus)” side.
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
ds_61282_83_en_tc: 060313J 5
TC (ACTC)
Double make contact 2 Form A type/Standard type
Pin in Paste type External dimensions PC board pattern (Bottom view)
17.8 13
.701 .512
Air hole 7 9.6
.276 .378
Max. 1.0
Max. .039 16.4 6×1.6 dia.
.646 6×.063 dia. 5 10.8
0.9
.035 .197 .425
A
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
Max. 1.0 7 8
Max. .039 16.4 .276 .315
.646
0.9
.035 A 4×1.6 dia.
4×.063 dia. 5 10.8
3.1 .197 .425
.122
0.6
.024
0.6
.024
0.4
.016
1.2 0.4 Tolerance: 0.1 .004
.047 .016
+
RESET SET
NO COM
5 10.8 (0.9)
–
.197 .425 (.035)
NO COM
+
Dimension: Tolerance
COIL
Less than 1mm .039inch: 0.1 .004
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008 * The lamp control type has polarized contacts.
Min. 3mm .118 inch: 0.3 .012 Connect COM to the “+ (plus)” side.
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
6 ds_61282_83_en_tc: 060313J
TC (ACTC)
NOTES
Usage, transport and storage (3) Atmospheric pressure: 86 to 106 kPa
conditions The humidity range varies with the
1) Ambient temperature, humidity, and temperature. Use within the range
atmospheric pressure during usage, indicated in the graph below.
transport, and storage of the relay: (Temperature and humidity range for
(1) Temperature: –40 to +85C –40 to usage, transport, and storage)
+185F (Standard type) Humidity, %RH
–40 to +110C –40 to +230F (High heat-
resistant type/Pin in Paste type) 85
(2) Humidity: 2 to 85% RH (Avoid Tolerance range
freezing and condensation.)
(Avoid freezing (Avoid
when used at condensation
temperatures when used at
lower than temperatures
0°C 32°F) higher than
0°C 32°F)
5
–40 0 85
–40 +32 +185
Temperature, °C °F
Humidity, %RH
85
Tolerance range
–40 0 85 110
–40 +32 +185 +230
Temperature, °C °F
ds_61282_83_en_tc: 060313J 7