MODEL 906

Battery “Fuel” Gauge


®

Read Instructions Carefully!


SAFETY INSTRUCTIONS

This instrument was manufactured and tested according to the


applicable technical standards. It complies with all the safety
regulations as shipped from the factory.

Installation and startup must be performed by skilled personnel.

Failure to install and operate the unit in accordance with these


instructions may result in damage or injury.

If safe operation of the instrument can no longer be ensured,


stop and secure it against accidental operation.

If instrument failure or malfunction may cause personal injury


or material damage, use additional safety measures such as
limit switches, guards, etc.

Read the Operating Instructions carefully before startup.

Note the safety instructions marked with this


warning symbol in this manual!
TABLE OF CONTENTS
1. Model Encodement 2
2. Technical Specifications
2.1 Electrical 6
2.2 Mechanical 6
2.3 Environmental 7
2.4 EMC 8
3. Installation 9
4. Operation
4.1 Display 10
4.2 Reset 11
5. Troubleshooting 12
6. Maintenance 13
7. Warranty 14
1. MODEL ENCODEMENT
1 3 5 7
Case Style Reset Output Artwork

Example: Model 906 D 24 M C D A O


Voltage Discharge Special
Options
2 4 6

1 Case Style Options 2 Voltage


Options
D DIN case – rectangular
F Hex bezel w/1/4” spade terminals (enGage I) 12
J Hex bezel w/Packard connector (enGage I) 24
N DIN case - rectangular, snap-fit 36
P Pin mount (module) 48
R 52mm Round bezel & case (same as 700Q)
T Hex bezel w/3/16” spade terminals (enGage I)
TX Hex bezel w/3/16” spade terminals (old T case)
Y Rectangular bezel w/Packard connector (enGage I)
Z Rectangular bezel w/1/4” spade terminals (enGage I)
2
3 Reset Profile Options
Profile with Profile without Volts per Cell
Memory Option Memory Option CTR
OCR HVR CTR Full Empty
K 1.928 2.167 2.167 2.10
J N/A 2.167
Y 2.083 2.167 2.167 2.10
N 1.980 2.230 2.230 2.10
E N/A 2.230
T 2.028 2.280 2.28 2.10
L N/A 2.280
D 2.060 2.320 2.32 2.10
P N/A 2.320
B 2.090 2.350 2.35 2.10
H N/A 2.350
C 2.135 2.400 2.400 2.10
M N/A 2.400
F N/A 2.416

3
4 Discharge Profile Options
Volts per Cell
Letter Code
Full Empty
G 1.97 1.75
H 1.97 1.70
J 1.97 1.63
K 2.01 1.65
L 2.10 1.92
M 2.00 1.83
N 2.04 1.73
P 2.08 1.98
Q 2.10 1.88
R 2.02 1.90
S 2.08 1.85
T 2.03 1.90
V 1.98 1.85
W 2.02 1.85
X 1.95 1.75
Y 2.00 1.90
Note: This gauge is not intended to measure the state-of-charge of batteries
subject to extended periods of inactivity since it does not account for self-
discharge effects. Consult factory for details.
4
5 Output Options
Letter
Signal
Code
A No option
B1 Both output & memory options
C1 Both output & memory options and CTR reset instead of HVR
D Output option only
M Memory option only
1 option is for micro versions only

6 Special Options 7 Artwork Options


A = (TBD)
Letter Code Logo

O Curtis
N None

5
2. TECHNICAL SPECIFICATIONS
2.1 Electrical Operating Voltage
Operating Range: ±25% of nominal voltage

Operating Current
Voltage Nominal Current Maximum Current
(VDC) (mA) (mA @B+ +25%)

12 23 38

24 17 24

36 16 22

48 16 21

2.2 Mechanical Display


10-digit
Red LED
Tri-color (5 green, 3 yellow, 2 red)

6
Recommended Panel Cutouts
F, J, T, TX, Y, Z Cases: 36.8 mm x 24.1 mm
+0.3/–.0 mm
D, N Cases: 45.3 mm x 22.3 mm ±0.1
R Case: 52.4 mm

Terminals
D, N, T, TX: 3/16” blade
R, F, Z: 1/4” blade
J, Y: 4-pin Packard Connector equivalent to
Delphi PN 15336035
P: Solder pins

2.3 Environmental Temperature


Operating: –40°C to +85°C
Storage: –50°C to +90°C
Humidity: 95% RH non-condensing at 38°C
Shock and Vibration: Meets SAE J 1378

7
2.4 EMC
Emissions
Radiated and Conducted Emissions: EN 61000-6-4
Immunity
Designed to meet: EN 61000-6-2
ESD: EN 61000-4-2
RF Immunity: EN 61000-4-3
Regulatory Approvals
CE: The product complies with the requirements of the
RoHS directive 2015/863/EU (RoHS 3). This product
is excluded from CE EMC testing and must only be
sold to OEMs completing machine level EMC testing
for CE certification.

8
3. INSTALLATION
Connecting Model 906
Pin 1 = Battery +
Connects to the vehicle’s main positive (+) terminal.
Use as short a wire as practical.
Pin 2 = Battery –
Connects to the vehicle’s main negative (–) terminal
Use as short a wire as practical.
Note: Pins 1 & 2 are connected across the total
battery pack.
Pin 3 = Output Signal + or No Option
Output Signal option: 5 VDC ±0.5 VDC (90 µA
current source) above Empty, 0-0.1 VDC at Empty
1 VDC maximum (90 µA sink);
No Option: Pin 3 is left open.
Pin 4 = Keyswitch
Connects to Battery + through the switched terminal
of the keyswitch.

9
4. OPERATION
4.1 Display
1
1. Only when the battery is properly charged is the
right-most LED lit.

2
2. As the battery’s state-of-charge decreases,
successive LEDs light up, only one on at a time.
3
3. The 2nd-from-left LED flashes, indicating “energy
reserve” (70% depth of discharge).

4
4. The 2 left-most LEDs alternately flash, indicating
“empty” (80% depth of discharge).

4 3 1

10
4.2 Reset
OCR (Open Circuit Reset)
Upon reconnection of a battery the gauge will reset
if it measures 2.09 volts/cell or higher (example “B”
profile) (for units with memory option).
HVR (High Voltage Reset)
Gauge must measure >2.35 volts per cell for 6
continuous minutes during charging (example
“B” profile).
CTR (Charge Tracking Reset)
Display tracks charge level during opportunity
charging (requires gauge to be connected to
battery when charging).

11
5. TROUBLESHOOTING
The following checklist should help you troubleshoot any
problem with Model 906.

Problem Possible Cause


Keyswitch on and no display Terminals not connected or improper voltage;
Keyswitch not high

Stays at Full Model 906 voltage does not match battery


voltage

Will not reset Model 906 voltage does not match battery
voltage or battery not fully charged

Reset without terminals Not connected directly to battery


charging battery

Empty too soon Model 906 voltage does not match battery
voltage or terminals not connected directly
to battery

12
6. MAINTENANCE
Curtis Model 906 series is not field serviceable. Return
defective units to your distributor for warranty coverage.

13
7. WARRANTY
Curtis Instruments’ products and/or components are
guaranteed against defects in workmanship and material for
a period of one year, or as defined in the individual product
literature, from date of shipment from our factory, when applied
in a proper application within specified ratings. This guarantee
is limited to repair or replacement F.O.B. our factory. There
is no further warranty or implied representation, guarantee,
promise or agreement as to any Curtis Instruments product
and/or component. Curtis Instruments, Inc., cannot assume
responsibility or accept invoices for unauthorized repairs to
its products and/or components, even though defective. In no
case will Curtis Instruments’ responsibility extend to products,
components or equipment not of its manufacture. Under no
circumstances shall Curtis Instruments, Inc., be liable for any
special or consequential damages or loss of profits or other
damages. Returned goods will not be accepted unless
identified by a Curtis Return Material Authorization (RMA).

All specifications are subject to


change without notice.
14
CURTIS INSTRUMENTS, INC.
200 Kisco Ave.
Mount Kisco, New York 10549
914-666-2971 Tel
914-666-2188 Fax
www.curtisinstruments.com

53015 Rev. J 10/21